A This General Main Application sheet can be used for inserting, without of generic function blocks which A
are related to the IED only e.g. local/remote switch, some generic functions related to logic TRUE or
FALSE, push buttons logic (valid for certain IED types) etc.
General logic state TRUE and FALSE Protection setting GROUP selection
NOT Protection
IN OUT TRUE BI_SG_2 SG_LOGIC_SEL
O:24|T:2,5|I:0 BI_SG_3 SG_1_ACT
BI_SG_4 SG_2_ACT
BI_SG_5 SG_3_ACT
BI_SG_6 SG_4_ACT
SG_5_ACT
B SG_6_ACT B
BEH_TEST
NOT BEH_BLK
O:95|T:2,5|I:0
TRUE IN OUT FALSE
O:33|T:2,5|I:4
Local&remote control
CONTROL_LOCAL
Control
C NOT CTRL_OFF OFF C
CTRL_LOC LOCAL
IN OUT CTRL_STA STATION
O:25|T:2,5|I:2 CTRL_REM REMOTE CONTROL_REMOTE
CTRL_ALL ALL
BEH_TEST
BEH_BLK
DISTANCE O:32|T:2,5|I:0
D D
E E
A
The Binary Input/Ouput Main Application sheet contains hardware channels If you want to change the variable name, just double click on a variable name and edit the text. A
with connected variables.
If certain hardware channel is not available, just check the availability from the library If you want to change the order of connection between hardware channels and variables,
Insert--> Hardware channel --> Binary input / Binary output. just select the wire in between a variable and a function block and press "delete". Do not delete
the variable itself. Then make new connection to new binary input/output function block.
Variable names are standardized within the configuration. Once the variable is deleted,
check all relevant connections which were done within the whole configuration.
Binary inputs - X110 terminal block Binary outputs - X110 terminal block
RESSOR CHARGER
X110 (BIO-H)_110.X110-Input 1
B B
OR
B1 O REAREMENT DEFFAUT DJS
B2
X110 (BIO-H)_110.X110-HSO1
X110 (BIO-H)_110.X110-Input 2 O:23|T:2,5|I:9
OR
B1 O ARR 2 ARCSARC_OPERATE
B2
X110 (BIO-H)_110.X110-HSO2
X110 (BIO-H)_110.X110-Input 3 O:27|T:2,5|I:0
OR
C C
B1 O COUPLAG ARCSARC_OPERATE
B2
X110 (BIO-H)_110.X110-HSO3
X110 (BIO-H)_110.X110-Input 4 O:26|T:2,5|I:5
OR
B1 O
B2 DEF ARC.G1
X110 (BIO-H)_110.X110-Input 5 O:110|T:2,5|I:2
OR
B1 O DEF D'ISOL
B2
D X110 (BIO-H)_110.X110-Input 6 O:109|T:2,5|I:1 D
OR
B1 O ARRET D'UREGENCE
B2
X110 (BIO-H)_110.X110-Input 7 O:112|T:2,5|I:4
OR
B1 O
B2
X110 (BIO-H)_110.X110-Input 8 O:111|T:2,5|I:3
E E
A
The Binary Input/Ouput Main Application sheet contains hardware channels If you want to change the variable name, just double click on a variable name and edit the text. A
with connected variables.
If certain hardware channel is not available, just check the availability from the library If you want to change the order of connection between hardware channels and variables,
Insert--> Hardware channel --> Binary input / Binary output. just select the wire in between a variable and a function block and press "delete". Do not delete
the variable itself. Then make new connection to new binary input/output function block.
Variable names are standardized within the configuration. Once the variable is deleted,
check all relevant connections which were done within the whole configuration.
Binary outputs - X100 terminal block
CB_CLOSE_COMMAND
B X100 (PSM)_100.X100-PO1 B
CBXCBR1_ENA_CLOSE
X100 (PSM)_100.X100-PO2
TRPPTRC1_TRIP
X100 (PSM)_100.X100-SO1
X100 (PSM)_100.X100-SO2
CB_OPEN_COMMAND
X100 (PSM)_100.X100-PO3
C C
X100 (PSM)_100.X100-PO4
D D
E E
A
The Binary Input/Ouput Main Application sheet contains hardware channels If you want to change the variable name, just double click on a variable name and edit the text. A
with connected variables.
If certain hardware channel is not available, just check the availability from the library If you want to change the order of connection between hardware channels and variables,
Insert--> Hardware channel --> Binary input / Binary output. just select the wire in between a variable and a function block and press "delete". Do not delete
the variable itself. Then make new connection to new binary input/output function block.
Variable names are standardized within the configuration. Once the variable is deleted,
check all relevant connections which were done within the whole configuration.
DEFFAUT DJS
CB- OUVER
X130 (AIM)_130.X130-Input 1
B X120 (AIM)_120.X120-Input 1 B
CB-FERMET
DEF AUX
X120 (AIM)_120.X120-Input 2
X130 (AIM)_130.X130-Input 2
POS-SERVICE
X120 (AIM)_120.X120-Input 3 DISTANCE
X130 (AIM)_130.X130-Input 3
POS-TEST
X120 (AIM)_120.X120-Input 4
DEF CPI
X130 (AIM)_130.X130-Input 4
C C
D D
E E
A
The Measurement Main Application sheet contains measuring function blocks which are A
related to the IED.
All measurements are always activated by default.
The binary outputs from available function blocks can be utilized for any purpose
in the configuration.
Three phase current measurement Three phase voltage measurement Frequency measurement
B B
CMMXU1 VMMXU1 FMMXU1
BLOCK HIGH_ALARM BLOCK HIGH_ALARM O:115|T:5|I:1
HIGH_WARN HIGH_WARN
LOW_WARN LOW_WARN
LOW_ALARM LOW_ALARM
O:100|T:5|I:1 O:9|T:5|I:1 Three phase power and energy measurement
PEMMXU1
Sequence current measurement Sequence voltage measurement RSTACM
O:107|T:5|I:1
CSMSQI1 VSMSQI1
Data monitoring
O:97|T:5|I:1 O:96|T:5|I:1
C FLTRFRC1 C
BLOCK
Residual current measurement Residual voltage measurement CB_CLRD
O:7|T:2,5|I:1
RESCMMXU1
BLOCK HIGH_ALARM
RESVMMXU1 Load profile record
HIGH_WARN BLOCK HIGH_ALARM
O:102|T:5|I:1 HIGH_WARN
O:99|T:5|I:1 LDPRLRC1
RSTMEM MEM_WARN
MEM_ALARM
O:106|T:5|I:1
Three phase voltage measurement
D VMMXU2 D
BLOCK HIGH_ALARM
HIGH_WARN
LOW_WARN
LOW_ALARM
O:104|T:5|I:2
E E
A The Control & Interlocking Main Application sheet contains primary object function blocks logics. A
As an example: circuit breaker, disconnector, earth switch with additional control and/or interlocking
logic.
Circuit breaker 1
CBXCBR1
CB- OUVER POSOPEN SELECTED
CB-FERMET POSCLOSE EXE_OP CBXCBR1_EXE_OP
TRUE ENA_OPEN EXE_CL CBXCBR1_EXE_CL
CBXCBR1_ENA_CLOSE ENA_CLOSE OP_REQ
FALSE BLK_OPEN CL_REQ
BLK_CLOSE OPENPOS
CBXCBR1_AU_OPEN AU_OPEN CLOSEPOS
B CBXCBR1_AU_CLOSE AU_CLOSE OKPOS B
TRIP OPEN_ENAD
SYNC_OK CLOSE_ENAD
SYNC_ITL_BYP
O:55|T:5|I:1
External CLOSING command for Circuit breaker 1 External OPENING command for Circuit breaker 1
Connect here any additional signals for CLOSING of CB in LOCAL or REMOTE mode, if Connect here any additional signals for OPENING of CB in LOCAL or REMOTE mode, if
applicable for your configuration. applicable for your configuration.
AND AND
CONTROL_LOCAL B1 O CONTROL_LOCAL B1 O
C FALSE B2 FALSE B2 C
O:39|T:2,5|I:3 OR O:42|T:2,5|I:1 OR
B1 O CBXCBR1_AU_CLOSE B1 O CBXCBR1_AU_OPEN
B2 B2
AND O:49|T:2,5|I:7 AND O:50|T:2,5|I:6
CONTROL_REMOTE B1 O CONTROL_REMOTE B1 O
FALSE B2 FALSE B2
O:40|T:2,5|I:2 O:41|T:2,5|I:0
Signals for closing coil of Circuit breaker 1 Signals for opening coil of Circuit breaker 1
D Connect here any additional signals required by your application for closing of Connect here any additional signals required by your application for opening of D
circuit breaker. circuit breaker.
OR OR6
CBXCBR1_EXE_CL B1 O CB_CLOSE_COMMAND CBXCBR1_EXE_OP B1 O CB_OPEN_COMMAND
B2 TRPPTRC1_TRIP B2
O:58|T:2,5|I:10 B3
B4
B5
B6
O:59|T:2,5|I:13
E E
A The Control & Interlocking Main Application sheet contains primary object function blocks logics. A
As an example: circuit breaker, disconnector, earth switch with additional control and/or interlocking
logic.
Connect here any additional signals required by your application for closing of
circuit breaker.
DCSXSWI1
POS-TEST POSOPEN OPENPOS
POS-SERVICE POSCLOSE CLOSEPOS
OKPOS
O:43|T:5|I:1
NOT
DEFFAUT DJS IN OUT
O:45|T:2,5|I:1
AND NOT
ARR 2 B1 O IN OUT
COUPLAG B2 O:44|T:2,5|I:6
O:34|T:2,5|I:4
D D
E E
OR6 TRPPTRC1
OR6
B1 O BLOCK TRIP TRPPTRC1_TRIP
PHIPTOC1_OPERATE B1 O B2 OPERATE CL_LKOUT
PHLPTOC1_OPERATE B2 B3 RST_LKOUT
B3 B4 O:35|T:2,5|I:1
B4 B5 SR
DEF D'ISOL B5 B6
B6 O:22|T:2,5|I:10 S Q
ARRET D'UREGENCE O:21|T:2,5|I:8 R NOTQ
O:28|T:2,5|I:0
B B
OR6
EFLPTOC1_OPERATE B1 O REAREMENT
B2
EFIPTOC1_OPERATE B3
B4
B5
DEF ARC.G1 B6
O:20|T:2,5|I:7
OR6
B1 O
PHPTOV2[2]_OPERATE B2
PHPTUV2[2]_OPERATE B3
B4
PHPTOV1[1]_OPERATE B5
C B6 C
PHPTUV1[1]_OPERATE O:19|T:2,5|I:6
DEFFAUT DJS
D D
E E
TRPPTRC2
OR6 OR6
BLOCK TRIP TRPPTRC2_TRIP
PHIPTOC1_OPERATE B1 O B1 O OPERATE CL_LKOUT
PHLPTOC1_OPERATE B2 B2 RST_LKOUT
B3 B3 O:57|T:2,5|I:2
B4 B4
B5 B5
B6 B6
O:53|T:2,5|I:5 O:56|T:2,5|I:9
TRPPTRC1_TRIP
B B
OR6
B1 O
B2
EFLPTOC1_OPERATE B3
B4
EFIPTOC1_OPERATE B5
CCBRBRF1_TRRET B6
O:52|T:2,5|I:4
OR6
ARCSARC1_OPERATE B1 O
ARCSARC2_OPERATE B2
ARCSARC3_OPERATE B3
B4
B5
C B6 C
O:51|T:2,5|I:3
D D
E E
A A
B B
C C
D D
E E
OR6
OR6
B1 O
B EFLPTOC1_START B1 O B2 B
B2 B3
EFIPTOC1_START B3 B4
B4 B5 TPGAPC1
B5 B6
B6 O:72|T:2,5|I:26 IN1 OUT1 GENERAL_START_PULSE
O:61|T:2,5|I:24 IN2 OUT2 GENERAL_OPERATE_PULSE
O:87|T:2,5|I:1
OR6 OR6
PHLPTOC1_OPERATE B1 O B1 O
B2 B2
B3 B3
PHIPTOC1_OPERATE B4 B4
B5 B5
B6 B6
O:67|T:2,5|I:22 O:71|T:2,5|I:25
C C
OR6
EFIPTOC1_OPERATE B1 O
B2
EFLPTOC1_OPERATE B3
B4
PHPTOV2[2]_OPERATE B5
B6
PHPTUV2[2]_OPERATE O:66|T:2,5|I:21
OR6
ARCSARC1_OPERATE B1 O
ARCSARC2_OPERATE B2
ARCSARC3_OPERATE B3
PHPTOV1[1]_START B4
PHPTUV1[1]_START B5
D B6 D
O:65|T:2,5|I:20
E E
A The Protection Main Application sheets contain protection function blocks with predefined variables. A
If you want to enable ANSI names of protection functions set parameter in Tool->Options->
System Settings-> Naming Style.
If protection function is not used, delete relevant function blocks and the variables.
After that, check the application configuration.
PHIPTOC1 EFIPTOC1
BLOCK OPERATE PHIPTOC1_OPERATE BLOCK OPERATE EFIPTOC1_OPERATE
B ENA_MULT START ENA_MULT START EFIPTOC1_START B
O:12|T:2,5|I:1 PHIPTOC1_START O:13|T:2,5|I:1
PHHPTOC1
BLOCK OPERATE PHHPTOC1[1]_OPERATE
ENA_MULT START PHHPTOC1[1]_START
O:54|T:5|I:1
PHLPTOC1 EFLPTOC1
BLOCK OPERATE PHLPTOC1_OPERATE BLOCK OPERATE EFLPTOC1_OPERATE
ENA_MULT START ENA_MULT START EFLPTOC1_START
O:11|T:5|I:1 PHLPTOC1_START O:14|T:5|I:1
C C
OR6
EFIPTOC1_OPERATE B1 O EFxPTOC_OPERATE
Grouped function operate B2
B3
EFLPTOC1_OPERATE
B4
B5
OR6 B6
PHIPTOC1_OPERATE O:68|T:2,5|I:28
B1 O PHxPTOC_OPERATE
PHHPTOC1[1]_OPERATE B2
B3
PHLPTOC1_OPERATE B4
D B5 D
B6
O:70|T:2,5|I:27
E E
A A
PHPTOV1
BLOCK OPERATE PHPTOV1[1]_OPERATE
START PHPTOV1[1]_START
O:15|T:5|I:1
B B
PHPTOV2
BLOCK OPERATE PHPTOV2[2]_OPERATE
START PHPTOV2[2]_START
O:17|T:5|I:2
PHPTUV1
BLOCK OPERATE PHPTUV1[1]_OPERATE
START PHPTUV1[1]_START
O:16|T:5|I:1
PHPTUV2
C C
BLOCK OPERATE PHPTUV2[2]_OPERATE
START PHPTUV2[2]_START
O:18|T:5|I:2
D D
E E
A The Protection Main Application sheets contain protection function blocks with predefined variables. A
If you want to enable ANSI names of protection functions set parameter in Tool->Options->
System Settings-> Naming Style.
If protection function is not used, delete relevant function blocks and the variables.
After that, check the application configuration.
CCBRBRF1
B OR6 OR6 B
BLOCK CB_FAULT_AL
PHIPTOC1_OPERATE B1 O B1 O START TRBU CCBRBRF1_TRBU
B2 B2 POSCLOSE TRRET CCBRBRF1_TRRET
B3 B3 CB_FAULT
EFLPTOC1_OPERATE B4 B4 O:47|T:2,5|I:1
B5 B5
EFIPTOC1_OPERATE B6 B6
O:36|T:2,5|I:1 O:38|T:2,5|I:2
OR6
ARCSARC1_OPERATE B1 O
ARCSARC2_OPERATE B2
ARCSARC3_OPERATE B3
B4
B5
B6
O:37|T:2,5|I:0
C C
D D
E E
A
The Supervison Main Application sheet contains supervision function blocks A
e.g. Trip circuit supervision, Current Supervision and Condition monitoring functions.
Circuit Breaker condition monitoring function Logic for Circuit breaker monitoring alarm
Set parameters for SSCBR properly
OR6
SSCBR1_TRV_T_OP_ALM B1 O
SSCBR1 SSCBR1_TRV_T_CL_ALM B2
SSCBR1_SPR_CHR_ALM B3
BLOCK TRV_T_OP_ALM SSCBR1_TRV_T_OP_ALM SSCBR1_OPR_ALM B4
POSOPEN TRV_T_CL_ALM SSCBR1_TRV_T_CL_ALM SSCBR1_OPR_LO B5 OR
B POSCLOSE SPR_CHR_ALM SSCBR1_SPR_CHR_ALM SSCBR1_IPOW_ALM B6 B
CB_OPEN_COMMAND OPEN_CB_EXE OPR_ALM SSCBR1_OPR_ALM O:74|T:2,5|I:15 B1 O SSCBR1_ALARMS
CB_CLOSE_COMMAND CLOSE_CB_EXE OPR_LO SSCBR1_OPR_LO B2
PRES_ALM_IN IPOW_ALM SSCBR1_IPOW_ALM O:86|T:2,5|I:11
PRES_LO_IN IPOW_LO SSCBR1_IPOW_LO
CB_SPRING_DISCHARGED SPR_CHR_ST CB_LIFE_ALM SSCBR1_CB_LIFE_ALM OR6
SPR_CHR MON_ALM SSCBR1_MON_ALM
RST_IPOW PRES_ALM SSCBR1_PRES_ALM SSCBR1_IPOW_LO B1 O
RST_CB_WEAR PRES_LO SSCBR1_PRES_LO SSCBR1_CB_LIFE_ALM B2
RST_TRV_T OPENPOS SSCBR1_MON_ALM B3
RST_SPR_T INVALIDPOS SSCBR1_PRES_ALM B4
CLOSEPOS SSCBR1_PRES_LO B5
O:62|T:5|I:1 B6
O:73|T:2,5|I:14
Trip circuit supervision function Logic for start of Circuit breaker spring charging
C C
Set parameters for TCSSCBR properly
NOT
TCSSCBR1 IN OUT CB_SPRING_DISCHARGED
O:60|T:2,5|I:5
TCSSCBR_BLOCKING BLOCK ALARM TCSSCBR1_ALARM
O:75|T:5|I:1
TCSSCBR2
BLOCK ALARM
TCSSCBR_BLOCKING
O:69|T:5|I:2
TCSSCBR2_ALARM
Logic for blocking of trip circuit supervision
Grouped function alarm
D D
OR6
TRPPTRC1_TRIP B1 O TCSSCBR_BLOCKING
OR TRPPTRC2_TRIP B2
B3
TCSSCBR1_ALARM B1 O TCSSCBR_ALARM B4
TCSSCBR2_ALARM B2 B5
O:92|T:2,5|I:13 B6
O:63|T:2,5|I:19
E E
A The Logic Main Application sheet contains any additional logics required by your application. A
Variables within the configurations are prestandardized. To insert variables use variable list
in toolbar and use drag and drop functionality from the list to the page.
Timer logic for overcurrent operate and earth-fault operate Logic for upstream OC blocking
TPGAPC2
PHxPTOC_OPERATE IN1 OUT1
IN2 OUT2
B O:83|T:2,5|I:2 B
OR
EFxPTOC_OPERATE B1 O
B2
O:81|T:2,5|I:16
C C
D D
E E
A
The Optional Main Application sheet contains only optional/additional function blocks, A
which are only order code specific functions e.g. DARREC, ARC protection etc.
Autorecloser function
B B
C C
D D
E E
A
The Optional Main Application sheet contains only optional/additional function blocks, A
which are only order code specific functions e.g. DARREC, ARC protection etc.
ARCSARC2
BLOCK OPERATE ARCSARC2_OPERATE
REM_FLT_ARC ARC_FLT_DET
OPR_MODE ARCSARC2_ARC_FLT_DET
O:31|T:2,5|I:21
ARCSARC3
C BLOCK OPERATE ARCSARC3_OPERATE C
REM_FLT_ARC ARC_FLT_DET
OPR_MODE ARCSARC3_ARC_FLT_DET
O:29|T:2,5|I:31
OR6
B1 O ARCSARC_OPERATE
B2
ARCSARC3_OPERATE B3
B4
ARCSARC2_OPERATE B5
B6
O:85|T:2,5|I:30
D D
E E
A
This Disturbace Recorder Main Application sheet contains disturbance recorder A
function block and connections to variables.
One of the possible ways how the disturbance recorder can be utilized.
Once, the order of signals connected to binary inputs of RDRE is changed,
reflect the changes to parameter setting tool.
RDRE1
PHLPTOC1_START C1 TRIGGERED DISTURB_RECORD_TRIGGERED
C2
C3
PHIPTOC1_START C4
PHPTOV1[1]_START C5
C6
B PHPTOV2[2]_OPERATE EFLPTOC1_START C7 B
C8
EFIPTOC1_START C9
PHPTUV1[1]_START C10
PHPTUV2[2]_START C11
C12
C13
OR6 CCBRBRF1_TRRET C14
CCBRBRF1_TRBU C15
PHIPTOC1_OPERATE B1 O C16
PHHPTOC1[1]_START B2 C17
B3 C18
PHLPTOC1_OPERATE B4 C19
B5 C20
B6 C21
O:76|T:2,5|I:18 C22
C23
C24
ARCSARC1_OPERATE C25
OR ARCSARC2_OPERATE C26
ARCSARC3_OPERATE C27
C B1 O C28 C
B2 C29
O:77|T:2,5|I:12 C30
C31
C32
C33
OR6 C34
C35
EFLPTOC1_OPERATE B1 O C36
B2 C37
EFIPTOC1_OPERATE B3 C38
B4 C39
B5 C40
B6 C41
O:79|T:2,5|I:17 C42
C43
C44
C45
OR6 C46
C47
ARCSARC1_ARC_FLT_DET B1 O C48
D ARCSARC2_ARC_FLT_DET B2 C49 D
ARCSARC3_ARC_FLT_DET B3 C50
B4 C51
B5 C52
B6 C53
O:78|T:2,5|I:16 C54
C55
C56
C57
C58
C59
C60
C61
C62
C63
C64
O:89|T:2,5|I:1
E E
A The LED Main Application sheet contains programmable LED function blocks with initialization logic. A
If any LED function block is missing, insert it from the object library, Insert--> FunctionBlock --> Local HMI
LED6
LED1
RESSOR CHARGER OK
OK ALARM
TRPPTRC1_TRIP ALARM RESET
REAREMENT RESET O:4|T:2,5|I:6
O:90|T:2,5|I:1
LED7
B B
POS-SERVICE OK
ALARM
LED2 RESET
O:8|T:2,5|I:7
DEFFAUT DJS OK
ALARM
REAREMENT RESET
O:94|T:2,5|I:2
LED8
OR
POS-TEST OK
PHPTOV1[1]_OPERATE B1 O ALARM
B2 RESET
O:80|T:2,5|I:8 LED3 O:122|T:2,5|I:8
PHPTUV1[1]_OPERATE
OK
ALARM
REAREMENT RESET
C O:93|T:2,5|I:3 LED9 C
CB-FERMET OK
ALARM
LED4 RESET
O:119|T:2,5|I:9
ARR 2 OK
ALARM
RESET
O:88|T:2,5|I:4
LED10
CB- OUVER OK
LED5 ALARM
RESET
OK O:121|T:2,5|I:10
COUPLAG ALARM
RESET
O:84|T:2,5|I:5
D LED11 D
CBXCBR1_ENA_CLOSE OK
LEDPTRC1 ALARM
RESET
RESET OUT_START O:91|T:2,5|I:11
OUT_OPERATE
OUT_ST_A
OUT_OPR_A
REAREMENT OUT_ST_B
OUT_OPR_B
OUT_ST_C
OUT_OPR_C
OUT_ST_NEUT
OUT_OPR_NEUT
O:82|T:2,5|I:1
E E
A The Communication Main Application sheet contains communication function blocks e.g. GOOSE, diagnostic function blocks. A
Protocol instantiation
MBSLPRT1
Status
O:123|T:2,5|I:1
B B
C RCHLCCH1 C
CHLIV_A
REDCHLIV_B
LNKLIV_A
REDLNKLIV_B
O:6|T:2,5|I:1
D D
E E