3. A unit equivalent to a flow rate of 1cfm or 11. The minimum size of building supply pipe
1gpm of water. allowed by the code for water is .
a. Fixture Unit a. ¾ inch (19mm)
b. SI unit b. 1 inch
c. English unit c. ½ inch
d. No. of water closet d. 1 ¼ inch
4. A fixture designed for washing of hands or 12. The critical marking level of a backflow
face, sometimes called wash basin. prevention device or a vacuum breaker is a
a. Sink point established by the .
b. Lavatory a. Testing Laboratory
c. Bathtub b. Health officer
d. Shower c. Inspector
d. Manufacturer
5. A condition in distribution system where it
could damage or create condition that will 13. In water supply piping, slip joints may be
damage components of the distribution used only on the .
system or create a nuisance is termed as a. Cold water supply
. b. Concealed fixture
a. Excessive water pressure c. Exposed fixture supply
b. Loss of pressure d. Hot water supply
c. Excessive air pressure
d. Loss of water flow 14. An automatic fill device commonly found in
toilet tanks.
6. Air pressure in drainage pipe greater than a. Globe valve
atmospheric pressure. b. Ballcock
a. Standard pressure c. Butterfly valve
b. Normal pressure d. Gate valve
c. Back pressure
d. Barometric pressure 15. Equipment which includes all valves and
controls used in the plumbing system which
7. No clerical toilet shall be installed in are required to be accessible or readily
any building unless first approved by the accessible is called .
. a. Machines
a. Health officer b. Controls
b. Nurse c. Regulating equipment
c. Doctor d. Pipes
d. Medical representative
16. The level in a fixture at which the water
8. The minimum pressure that should be begins to overflow over the top rim of the
maintained for fixtures containing flush fixture.
tank supplies shall be . a. Flood level rim
a. 8 psi b. Flood level
b. 4.34 psi c. Rim
37. Fixture traps for a lavatory shall 44. Where potable water is discharged to the
a. Be self-cleaning drainage system, it shall be by means of
b. Have a J-bend a. An approved airgap of two pipe
c. Have a brass cleanout plug for diameters from the supply outlet and
cleaning purposes the top surface of the drainage
d. Be designed to avoid fungus growth inlet
b. No case shall the gap be less than
38. A trap depending on movable parts to retain 25mm
its seal may c. Both a & b
a. Be used for fixtures with clear d. None of the above
water waste only
b. Not be used under any circumstances 45. In setting of urinals, what is the minimum
c. Be used if first approved by center to center distance allowed by the
plumbing official code, in meters?
a. 0.60
46. Watercloset and urinal flushometer valves 53. Bases of soil stacks must be supported
shallbe equipped with a. With concrete blocks
a. A listed vacuum breaker b. By concrete piers
b. A listed ballcock c. To the satisfaction of plumbing
c. An approved backflow prevention inspector
assembly, device or method d. To the satisfaction of the job
d. Listed construction and materials engineer
47. The developed length of the trap arm from 54. The developed length between the trap of a
the weir to the inner edge of the vent water closet or similar fixture measured
shall in no case be less than from the top of closet ring (closet flange)
a. 1 pipe size larger than the trap arm to inner edge of vent shall not exceed
diameter a. 1200mm
b. 2 times the diameter of the trap arm b. 1229mm
c. 2 pipe size larger than the trap arm c. 1800mm
diameter d. 1829mm
d. 4 times the diameter of the trap arm
55. All shower compartment shall have a min.
48. Each such tailpiece, continuous waste or finished interior area of square
waste and overflow shall not be less than meter & shall be capable of encompassing a
for lavatories, drinking fountains 762mm diameter circle
and similar small fixtures a. 0.60
a. 32mm inside diameter b. 0.80
b. 32mm outside diameter c. 0.70
c. 38mm inside diameter d. 0.90
d. 38mm outside diameter
56. When a water service pipe is installed in
49. Water closet and urinal tanks shall be the same trench with a building sewer,
equipped with there must be a minimum separation of
a. A listed vacuum breaker a. 6 inches
b. A listed ballcock b. 10 inches
c. An approved backflow prevention c. 12 inches
assembly, device or method d. 18 inches
d. Listed construction and materials
57. In no case shall any dam or threshold be
50. Trap arms , the change of in depth when measured from the top
direction not exceeding 22 ½ degree no of the dam or threshold of the drain
cleanout is required, and for change of a. more than 51mm nor less than 228mm
direction greater than 22 ½ degree a b. less than 51mm nor more than 288mm
cleanout is required at the bend c. less than 51mm nor more than 228mm
a. 51 mm in diameter and larger d. less than 25mm nor more than 228mm
b. 76 mm in diameter and larger
c. 32 mm in diameter and larger 58. The critical level of a vacuum breaker
d. 38 mm in diameter and larger installed in a urinal is measured from
a. Highest part of the urinal
51. Cleanout in piping 51 mm or less in size b. Floor
shall be installed so that there is a c. Bottom part of the urinal
clearance of not less than in front d. None of the above
of the cleanout.
a. 504mm 59. Consists of a loaded air inlet valve, an
b. 102mm internally loaded check valve, 2 properly
c. 305mm located test cocks and 2 isolation gate
d. 450mm valves
a. PVB
52. Floor drain or similar traps directly b. RP
connected to the drainage system and c. DC
subject to infrequent use shall be provided d. AVB
with
a. Basket and strainer