ELECTRICAL SYMBOLS ELECTRICAL GENERAL NOTES:
SYMBOL DESCRIPTION 1. ALL ELECTRICAL INSTALLATIONS HEREIN AND OTHER RELATED WORKS TO BE DONE IN
THIS BUILDING SHALL BE IN ACCORDANCE WITH THE PROVISIONS AND STANDARDS OF
CEILING LIGHT THE FOLLOWING:
1.1 THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE.
SPOTLIGHT 1.2 REPUBLIC ACT 7926 OTHERWISE KNOWN AS THE NEW ELECTRICAL
ENGINEERING LAW
PENDANT LIGHT 1.3 THE NATIONAL BUILDING CODE OF THE PHILIPPINES.
1.4 FIRE CODE OF THE PHILIPPINES.
CONVENIENCE OUTLET 1.5 EXISTING RULES AND REGULATION OF THE LOCAL POWER UTILITY COMPANY.
CO 1.6 THE EXISTING CITY/MUNICIPAL ORDINANCES AND,
WATERPROOF OUTLET 1.7 THE BUREAU OF LABOR STANDARDS.
WP 2. ALL ELECTRICAL INSTALLATIONS HEREIN SHALL BE DONE UNDER THE DIRECT
SUPERVISION OF A DULY REGISTERED ELECTRICAL ENGINEER. HE SHALL BE RESPONSIBLE
REFRIGERATOR OUTLET
Ref IN THE INTERPRETATION OF THE PLANS AND SPECIFICATION AND THE REQUIRED
STANDARDS OF THE ELECTRICAL CODE.
RANGE OUTLET
r 3. MATERIALS AND EQUIPMENT TO BE USED SHALL HAVE INSPECTED COMMODITY
CLEARANCE (ICC) LABEL FOR FOREIGN MADE PRODUCTS AND P.S. MARK FOR LOCAL IN
AIR CONDITION UNIT OUTLET NATURE OF THE BUREAU OF PRODUCT STANDARD (BPS).
ACU
PB 4. PROVIDE GROUNDING WIRE TO ALL OUTLETS AND LIGHTING CIRCUITS, ALL NON CURRENT
PANEL BOARD - PB CARRYING METAL PARTS SHALL BE GROUNDED AND BOBDED INCLUDING FENCE AND
GATE.
CIRCUIT BRANCH 5. ALL PANEL BOARDS, MAIN DISTRIBUTION PANELS, ETC., SHALL HAVE GROUNDING BUS FOR
BRANCH CIRCUITS AND SUB FEEDER GROUNDING SYSTEM SHALL BE BONDED TO THE
CIRCUIT HOMERUN NEAREST METAL WATER PIPE.
6. MOUNTING HEIGHT FOR ALL WIRING DEVICES AND PANEL BOARDS SHALL BE.
S1 SINGLE GANG SWITCH 6.1 LIGHTING OUTLETS 1.40M ABOVE FLOOR FINISH.
6.2 CONVENIENCE OUTLETS 0.30M ABOVE FLOOR FINISH.
6.3 TELEPHONE OUTLETS 0.30M ABOVE FLOOR FINISH.
S2 DOUBLE GANG SWITCH
6.4 PANEL BOARDS & CABINETS 1.40M ABOVE FLOOR FINISH.
7. WIRING METHODS SHALL BE AS FOLLOWS:
S3 TRIPLE GANG SWITCH
7.1 SERVICE ENTRANCE RESISTS INTERMEDIATE METALLIC
CONDUIT (IMC).
M KILOWATTHOUR METER
7.2 LIGHTING AND POWER SYSTEM POLYVINYL CHLORIDE (PVC).
7.3 TELEPHONE OUTLETS POLYVINYL CHLORIDE (PVC).
SERVICE ENTRANCE 7.4 ALL VIBRATING EQUIPMENTS LIQUID TIGHT FLEXIBLE METAL
CONDUIT.
GROUND LUGS 8. NO CHANGES OR MODIFICATION SHALL BE MADE WITHOUT THE DESIGNERS WRITTEN
CONSENT.
SWITCH LINE 9. ALL WORKS SHALL BE EXECUTED IN A WORKMANSHIP MANNER AND SHALL PREVENT A
NEAT AND ORDERLY ACCEPTANCE. ALL WIRING SHALL BE CONCEALED IN THE LEAST
CIRCUIT LINE POSSIBLE WAY.
7.98 7.98
2.73 2.00 2.73 3.25 2.00
2.00 0.73 2.15 1.10 0.85 1.15 2.00 0.73 0.85 1.10
GARDEN
POCKET
2.03
2.03
OPEN
KITCHEN TO
BEDROOM 1 BELOW
BEDROOM 4 BEDROOM 2
SS S
REF SS
2
1.40
1.40
LANAI
T&B 1 T&B 2
S SS S SS
3.00
3.00
BALCONY S SS
0.90
0.90
DINING
UP HALLWAY
1.60
1.60
UP S DN
SS OPEN
10.03
10.03
SSS S TO
BELOW
STO.
2.30
2.30
BEDROOM 3
TV CABINET
2.00
2.00
LIVING
S SHELF
SS
LEDGE
CARPORT PORCH GARDEN
1
3.00
3.00
LOCATION OF
SEPTIC TANK
GARDEN
1 GROUND FLOOR ELECTRICAL PLAN 2 SECOND FLOOR ELECTRICAL PLAN
A-6 SCALE 1:100M A-6 SCALE 1:100M
7.98 7.98
2.73 2.00 2.73 3.25 2.00
2.00 0.73 2.15 1.10 0.85 1.15 2.00 0.73 0.85 1.10
r ACU
7
2.03
2.03
5 ACU 10 11
ACU
CO CO
WP CO CO CO
WP
1.40
1.40
Ref
3.00
3.00
6
0.90
0.90
CO
1.60
1.60
CO CO CO
10.03
10.03
WP
CO
2.30
2.30
4
9
2.00
2.00
ACU CO CO ACU
PB
WP
8
3
3.00
3.00
1 GROUND FLOOR POWER PLAN 2 SECOND FLOOR POWER PLAN
A-7 SCALE 1:100M A-7 SCALE 1:100M
MAIN & NEUTRAL FEEDER MAIN BREAKER
2 - 50 mm2 TW WIRE 150 AT
ON 40MM ø UPVC PIPE
20 AT 15 AT
L.O. 1 2 L.O.
SERVICE ENTRANCE
20 AT 30 AT
PRIVATE C.O. 3 4 A.C.
CONC. POLE
40 MM ø UPVC PIPE 30 AT 30 AT
A.C. 5 6 REF.O.
30 AT 15 AT
1 RISER DIAGRAM R.O. 7 8 C.O.
A-9 SCALE 1:100M
30 AT 30 AT
A.C. 9 10 A.C.
WATT-HOUT METER
30 AT 20 AT
A.C. 11 12 SPARE
N.G.L.
SCHEDULE OF LOADS (PANEL BOARD)
DEMAND
BRANCH CKT. NO. LOAD DESCRIPTION NO. OF LOADS LOAD (VA) VOLTS (V) AMPERES (A) CB RATING / AT SIZE OF WIRE & CONDUIT GROUND ROD
1 LIGHTING OUTLET 25 2500 230 10.87 20 3.5 MM² THWN WIRE IN 15MM ø UPVC PIPE
2 LIGHTING OUTLET 13 1300 230 5.65 15 2.0 MM² THWN WIRE IN 15MM ø UPVC PIPE
2 PANEL BOARD DETAIL
3 2-GANG WP/ CONVEN. OUTLET 9 3240 230 14.09 20 3.5 MM² THWN WIRE IN 15MM ø UPVC PIPE A-9 SCALE 1:100M
4 ACU OUTLET 1.5 HP 1 2300 230 10.00 30 5.5 MM² THWN WIRE IN 15MM ø UPVC PIPE
5 ACU OUTLET 1.5 HP 1 2300 230 10.00 30 5.5 MM² THWN WIRE IN 15MM ø UPVC PIPE
6 REF OUTLET 1 HP 1 1840 230 8.00 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE
7 RANGE OUTLET 1 5000 230 21.74 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE
8 2-GANG WP/ CONVEN. OUTLET 7 2520 230 10.96 15 2.0 MM² THHN WIRE IN 15MM ø UPVC PIPE
9 ACU OUTLET 1.5 HP 1 2300 230 10.00 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE
10 ACU OUTLET 1.5 HP 1 2300 230 10.00 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE
11 ACU OUTLET 1.5 HP 1 2300 230 10.00 30 5.5 MM² THHN WIRE IN 15MM ø UPVC PIPE
TOTAL 27900 230 121.30 150 50 MM² THHN WIRE IN 40MM ø UPVC PIPE
COMPUTATIONS: MINIMUM AMPACITY OF MAIN FEEDER: SIZE OF MAIN WIRE & CONDUIT:
TOTAL CONNECTED LOADS IL = 27900/230 = 121.30 AMPS I =150 AMPS (0.80) THEREFORE USE 2 - 50 mm2 TW WIRE FOR THE MAIN-FEEDER AND
80% ACTUAL LOAD: DEMAND FACTOR = 121.30 x 80% = 97.04 AMPS I = 120 AMPS 150 A FOR THE MAIN BREAKER ON 40MM ø UPVC PIPE.
M
POWER SERVICE
ENTRANCE 230V,
50 MM Ø, 3W 60Hz
25-100 W LIGHTING OUTLET 1 20A 15A 2 13-100 W LIGHTING OUTLET
2-GANG WP/ CONVEN. OUTLET 3 20A 30A 4 ACU OUTLET 1.5 HP
ACU OUTLET 1.5 HP 5 30A 30A 6 REF OUTLET 1.5 HP
RANGE OUTLET 7 30A 15A 8 2-GANG WP/ CONVEN. OUTLET
ACU OUTLET 1.5 HP 9 30A 30A 10 ACU OUTLET 1.5 HP
ACU OUTLET 1.5 HP 11 30A 20A 12 SPARE
30 MM Ø x 3 M
COPPER CLAD 1 ONE LINE DIAGRAM
GRD ROD A-10 SCALE 1:100M