Flash Codes For The Combi D
Flash Codes For The Combi D
2010
Please note* lines highlighted in yellow contain the changed assignment of the fault numbers: valid from Index 4/12, 6/12, 4/12A, 6/12A
Please note* lines highlighted in pale orange contain the changed assignment of the fault numbers: valid from Index 4/11, 6/11
Please note lines highlighted in light green contain the revised fault numbers: valid for all versions
0 s,s,s,s s,s,s,s unassigned recheck flash code
1 s,s,s,s s,s,s,l unassigned recheck flash code
2 s,s,s,s s,s,l,s unassigned recheck flash code
3 s,s,s,s s,s,l,l unassigned recheck flash code
4 s,s,s,s s,l,s,s current for combustion air motor too high combustion air motor or cable harness check / replace combustion air motor check / replace cable harness of combustion replace electronic PCB
defective air motor
5 s,s,s,s s,l,s,l current for combustion air motor too low combustion air motor or cable harness check / replace combustion air motor check / replace cable harness of combustion replace electronic PCB
defective air motor
6 s,s,s,s s,l,l,s current for combustion air motor too high combustion air motor or cable harness check / replace combustion air motor check / replace cable harness of combustion replace electronic PCB
defective air motor
7 s,s,s,s s,l,l,l unassigned recheck flash code
8 s,s,s,s l,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
9 s,s,s,s l,s,s,l unassigned recheck flash code
10 s,s,s,s l,s,l,s plausibility of combustion air temperature combustion air temperature sensor outside check cable of combustion air temperature check (read) / replace combustion air
sensor tolerance range sensor temperature sensor
11 s,s,s,s l,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
12 s,s,s,s l,l,s,s unassigned recheck flash code
13 s,s,s,s l,l,s,l unassigned recheck flash code
14 s,s,s,s l,l,l,s unassigned recheck flash code
15 s,s,s,s l,l,l,l unassigned recheck flash code
15* s,s,s,s l,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
16 s,s,s,l s,s,s,s unassigned recheck flash code
16* s,s,s,l s,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
17 s,s,s,l s,s,s,l unassigned recheck flash code
18 s,s,s,l s,s,l,s unassigned recheck flash code
19 s,s,s,l s,s,l,l plausibility of electronic heater does not match electronics install correct electronics
(e.g. 6 kW PCB in 4 kW heater)
20 s,s,s,l s,l,s,s plausibility of NTC water temperature water temperature sensor outside tolerance check cable of water temperature sensor check (read) / replace water temperature
range sensor
20°C 12.6 k Ω
25°C 10.0 k Ω
40°C 5.0 k Ω
50°C 3.3 k Ω
21 s,s,s,l s,l,s,l plausibility of NTC room temperature room temperature sensor outside tolerance check cable of room temperature sensor check (read) / replace room temperature
range sensor
15°C 16.2 k Ω
20°C 12.6 k Ω
25°C 10.0 k Ω
22 s,s,s,l s,l,l,s plausibility of NTC air temperature air temperature sensor outside tolerance range check cable of air temperature sensor check (read) / replace air temperature sensor check the thermostat plate /
20°C 124.9 k Ω air temperature switch /
25°C 100.0 k Ω air temperature sensor
50°C 36.0 k Ω for damage caused by overheating
=> inform the customer service
23 s,s,s,l s,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
24 s,s,s,l l,s,s,s current for warm air motor too high warm air motor failure check (apply 12 V) / replace warm air motor replace electronics
25 s,s,s,l l,s,s,l current for warm air motor too low warm air motor or connection plug failure check / replace warm air motor replace electronics
Please note* lines highlighted in yellow contain the changed assignment of the fault numbers: valid from Index 4/12, 6/12, 4/12A, 6/12A
Please note* lines highlighted in pale orange contain the changed assignment of the fault numbers: valid from Index 4/11, 6/11
Please note lines highlighted in light green contain the revised fault numbers: valid for all versions
26 s,s,s,l l,s,l,s current for warm air motor too high warm air motor failure check (apply 12 V) / replace warm air motor replace current electronics for latest
replacement PCB (from version 12 A)
27 s,s,s,l l,s,l,l unassigned recheck flash code
28 s,s,s,l l,l,s,s current for control panel too high control panel or control panel cable failure check / replace control panel cable replace control panel replace electronic PCB
29 s,s,s,l l,l,s,l current for FrostControl heating element too heating element or cable defective check / replace heating element replace electronics
high
30 s,s,s,l l,l,l,s current for solenoid valve 2 KW retaining coil solenoid coil or cable harness defective check / replace solenoid coil check / replace cable harness replace electronic PCB
too high
31 s,s,s,l l,l,l,l current for solenoid valve 4 KW retaining coil solenoid coil or cable harness defective check / replace solenoid coil check / replace cable harness replace electronic PCB
too high
32 s,s,l,s s,s,s,s unassigned recheck flash code
33 s,s,l,s s,s,s,l current for solenoid valve 2 KW restraining solenoid coil or cable harness defective check / replace solenoid coil check / replace cable harness replace electronic PCB
coil too high
34 s,s,l,s s,s,l,s current for solenoid valve 4 KW restraining solenoid coil or cable harness defective check / replace solenoid coil check / replace cable harness replace electronic PCB
coil too high
35 s,s,l,s s,s,l,l unassigned recheck flash code
36 s,s,l,s s,l,s,s current for ignitor too high ignitor or cable harness defective replace ignitor check / replace cable harness
37 s,s,l,s s,l,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
38 s,s,l,s s,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
39 s,s,l,s s,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
40 s,s,l,s l,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
41 s,s,l,s l,s,s,l electronic blocked electronic blocked: – check the heating system check / replace: replace electronic PCB
– because the air temperature switch for over-heating damage – air temperature switch and cable
and / or water temperature switch opened – check the thermostat plate / – water temperature switch
during operation. air temperature switch / – combustion air temperature sensor and cable
– because the air temperature switch is air temperature sensor harness
damaged for damage caused by overheating
– due to a short-circuit of the combustion air => inform the customer service
temperature sensor
42 s,s,l,s l,s,l,s window switch open window opened with window switch / bridge for close window / check / replace window switch check secure fit / contact of bridge on PCB replace electronic PCB
window switch on electronics interrupted with cable
43 s,s,l,s l,s,l,l over voltage higher than 15 V 12 V power supply failure recondition power supply 12 V replace electronics
44 s,s,l,s l,l,s,s under voltage lower than 10.5 V 12 V power supply failure recondition power supply 12 V replace electronics
45 s,s,l,s l,l,s,l no 230 V supply to Combi E 230 V power supply failure check 230 V voltage reset / check 230 V WTS
Please note* lines highlighted in yellow contain the changed assignment of the fault numbers: valid from Index 4/12, 6/12, 4/12A, 6/12A
Please note* lines highlighted in pale orange contain the changed assignment of the fault numbers: valid from Index 4/11, 6/11
Please note lines highlighted in light green contain the revised fault numbers: valid for all versions
46 s,s,l,s l,l,l,s – control panel Combi or – control panel or control panel cable defective check / replace control panel/cable and plug- check supply line of combustion air motor - check electronic PCB for paint spray
energy selector switch Combi E defective – energy selector switch Combi E or control in contact on the electronics black cable for short-circuit to ground or red in control panel socket (replace
panel connection cable defective cable for interruption / replace cable harness (if electronic PCB)
– combustion air motor defective. cable harness not damaged, replace
– combustion air motor or hot-air motor – cable harness defective combustion air motor)
defective – electronics defective (paint spray in control
panel socket)
– internal connection between the (+) carbon
– battery earth to the minus terminal Combi brushes and/or DC motor and DC motor
defective casing via carbon dust
– earth connection from the power supply is
missing
47 s,s,l,s l,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
48 s,s,l,l s,s,s,s unassigned recheck flash code
48* s,s,l,l s,s,s,s water temperature switch over-temperature or fault: – check the heating system – check / replace the water temperature switch replace electronic PCB
air temperature switch over-temperature – because the air temperature switch for over-heating damage and water temperature sensor (Error 41 can occur by switching on /
and / or water temperature switch opened – check the thermostat plate / – check / replace the air temperature switch / off – see error no.41)
during operation. air temperature switch / sensor and cable
air temperature sensor – check / replace the circulating air motor
for damage caused by overheating
=> inform the customer service
49 s,s,l,l s,s,s,l unassigned for over-heating damage
49* s,s,l,l s,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
50 s,s,l,l s,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
51 s,s,l,l s,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
52 s,s,l,l s,l,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
53 s,s,l,l s,l,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
54 s,s,l,l s,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
55 s,s,l,l s,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
56 s,s,l,l l,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
57 s,s,l,l l,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
58 s,s,l,l l,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
59 s,s,l,l l,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
60 s,s,l,l l,l,s,s power fluctuation power supply not constant apply 12 V power supply replace electronics
61 s,s,l,l l,l,s,l failure due to ignition procedure ignition spark interfering with electronics ignitor must have orange label, otherwise check ignitor / flame rectification electrode replace electronic PCB
replace ignitor cable for damage / replace
62 s,s,l,l l,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
63 s,s,l,l l,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
64 s,l,s,s s,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
65 s,l,s,s s,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
66 s,l,s,s s,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
67 s,l,s,s s,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
68 s,l,s,s s,l,s,s failure due to ignition procedure ignition spark interfering with electronics ignitor must have orange label otherwise check ignitor / flame rectification electrode replace electronic PCB
replace ignitor cable for damage / replace
Please note* lines highlighted in yellow contain the changed assignment of the fault numbers: valid from Index 4/12, 6/12, 4/12A, 6/12A
Please note* lines highlighted in pale orange contain the changed assignment of the fault numbers: valid from Index 4/11, 6/11
Please note lines highlighted in light green contain the revised fault numbers: valid for all versions
69 k,l,k,k k,l,k,l monitoring the current of the hot-air motor – electronics defective replace electronic PCB replace the circulating air motor
– hot-air motor defective
70 s,l,s,s s,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
71 s,l,s,s s,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
72 s,l,s,s l,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
73 s,l,s,s l,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
74 s,l,s,s l,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
75 s,l,s,s l,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
76 s,l,s,s l,l,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
77 s,l,s,s l,l,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
78 s,l,s,s l,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
79 s,l,s,s l,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
80 s,l,s,l s,s,s,s AC current fluctuation power supply not constant apply clean 12 V power supply replace electronic PCB
(e.g. battery)
81 s,l,s,l s,s,s,l failure due to ignition procedure ignition spark interfering with electronics install earth cable, – check ignitor / flame rectification electrode replace the old ignitor with
part. no.: 34020-57000 cable for damage a new one with a blue label and red
(see also service info CB_110925) – replace check / adjust plug distances point or a blue label and Index 05
82 s,l,s,l s,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
83 s,l,s,l s,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
84 s,l,s,l s,l,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
85 s,l,s,l s,l,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
86 s,l,s,l s,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
87 s,l,s,l s,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
88 s,l,s,l l,s,s,s failure due to ignition procedure ignition spark interfering with electronics ignitor must have orange label, otherwise check ignitor / flame rectification electrode replace electronic PCB
replace ignitor cable for damage / replace
89 k,l,k,l l,k,k,l monitoring the current of the combustion – electronics fault replace electronic PCB replace combustion air motor
motor – combustion air motor fault
90 s,l,s,l l,s,l,s unassigned recheck flash code
91 s,l,s,l l,s,l,l unassigned recheck flash code
92 s,l,s,l l,l,s,s unassigned recheck flash code
93 s,l,s,l l,l,s,l unassigned recheck flash code
94 s,l,s,l l,l,l,s combustion air motor running at incorrect heater too hot or combustion air temperature check heater for damage due to overheating – check / replace combustion air motor, flue replace electronic PCB
speed sensor has incorrect value system and combustion air temperature sensor
– check gas supply
97 s,l,l,s s,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
98 s,l,l,s s,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
99 s,l,l,s s,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
100 k,l,l,k k,l,k,k – cable harness fault short circuit on solenoid valve coils – restart heating replace electronic PCB check / replace cable harness
– magnetic valve coils short circuit – check solenoid valve coils for short-circuit /
replace
101 k,l,l,k k,l,k,l – cable harness fault short-circuit on the ignitor – restart heating replace electronic PCB check / replace cable harness
– igniter short circuit – check igniter for short-circuit / replace
102 s,l,l,s s,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
Please note* lines highlighted in yellow contain the changed assignment of the fault numbers: valid from Index 4/12, 6/12, 4/12A, 6/12A
Please note* lines highlighted in pale orange contain the changed assignment of the fault numbers: valid from Index 4/11, 6/11
Please note lines highlighted in light green contain the revised fault numbers: valid for all versions
103 s,l,l,s s,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
104 s,l,l,s l,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
105 s,l,l,s l,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
106 s,l,l,s l,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
107 s,l,l,s l,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
108 s,l,l,s l,l,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
109 s,l,l,s l,l,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
110 s,l,l,s l,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
111 s,l,l,s l,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
112 s,l,l,l s,s,s,s – flame not detected – flame out or not detected (error may only – check gas supply install earth cable, – check flue system
occur after 3 – 5 minutes) part. no.: 34020-57000 – replace the ignition plugs
– poor earth or battery earth to the minus – ground connection from the supply voltage is – check earth connection of supply voltage (see also service info CB_110925) – replace electronic PCB
terminal Combi defective poor or does not exist – check installation of solenoid valve
– magnetic valve nozzle pipe canted
113 s,l,l,l s,s,s,l flame not expected ionization voltage present in standby mode check solenoid valve replace electronics
(stuck in open position)
114 s,l,l,l s,s,l,s unassigned recheck flash code
115 s,l,l,l s,s,l,l unassigned recheck flash code
116 s,l,l,l s,l,s,s dirty supply voltage AC components in supply voltage check supply voltage, AC components also only operate heater with battery replace electronic PCB
possible through power supply units or solar
systems
117 s,l,l,l s,l,s,l dirty supply voltage AC components in supply voltage check supply voltage, AC components also only operate heater with battery replace electronic PCB
possible through power supply units or solar
systems
118 s,l,l,l s,l,l,s combustion air motor running too slow combustion air motor running too slow or replace electronic PCB (if the Index is lower replace combustion air motor
outside tolerance range than 4/12, 6/12)
119 s,l,l,l s,l,l,l combustion air motor running too fast combustion air motor running too fast or ignitor must have orange label, otherwise check ignitor / flame rectification electrode replace combustion air motor and / or
outside tolerance range replace ignitor cable for damage / replace electronic PCB
Ignition spark interfering with electronics
120 s,l,l,l l,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
121 s,l,l,l l,s,s,l combustion air motor running at incorrect combustion air motor running at wrong speed / check gas supply check flue system – replace ignition plugs
speed flame unstable – replace electronic PCB
122 s,l,l,l l,s,l,s unassigned recheck flash code
123 s,l,l,l l,s,l,l unassigned recheck flash code
124 s,l,l,l l,l,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
125 s,l,l,l l,l,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
126 s,l,l,l l,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
127 s,l,l,l l,l,l,l electronic defective or combustion air motor failure in electronic PCB combustion air motor check / replace cable harness replace combustion air motor replace electronic PCB
running at incorrect speed defective cable harness defective
128 l,s,s,s s,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
129 l,s,s,s s,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
130 l,s,s,s s,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
131 l,s,s,s s,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
132 l,s,s,s s,l,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
133 l,s,s,s s,l,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
134 l,s,s,s s,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
Please note* lines highlighted in yellow contain the changed assignment of the fault numbers: valid from Index 4/12, 6/12, 4/12A, 6/12A
Please note* lines highlighted in pale orange contain the changed assignment of the fault numbers: valid from Index 4/11, 6/11
Please note lines highlighted in light green contain the revised fault numbers: valid for all versions
135 l,s,s,s s,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
136 l,s,s,s l,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
137 l,s,s,s l,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
138 l,s,s,s l,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
139 l,s,s,s l,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
140 l,s,s,s l,l,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
141 l,s,s,s l,l,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
142 l,s,s,s l,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
143 l,s,s,s l,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
144 l,s,s,l s,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
145 l,s,s,l s,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
146 l,s,s,l s,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
147 l,s,s,l s,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
148 l,s,s,l s,l,s,s combustion air temperature sensor electronic blocked: check heater for damage due to overheating – check / replace combustion air temperature replace electronic PCB
over temperature – because the combustion air temperature sensor and cable harness
sensor became too hot during operation due to – check / replace warm air motor
over-heating
– due to a short-circuit of the combustion air
temperature sensor
149 l,s,s,l s,l,s,l water temperature switch over-temperature electronic blocked: – check the heating system – check / replace the water temperature switch replace electronic PCB
or air temperature switch over-temperature – because the water temperature switch for over-heating damage and water temperature sensor
and / or air temperature switch opened during – check the thermostat plate / – check / replace the air temperature switch /
operation. air temperature switch / sensor and cable
air temperature sensor – check / replace the circulating air motor
for damage caused by overheating
=> inform the customer service
149* l,s,s,l s,l,s,l water temperature switch over-temperature fault: – check the heating system – check / replace the water temperature switch replace electronic PCB
or air temperature switch over-temperature – because the water temperature switch for over-heating damage and water temperature sensor
and / or air temperature switch opened during – check the thermostat plate / – check / replace the air temperature switch /
operation. air temperature switch / sensor and cable
air temperature sensor – check / replace the circulating air motor
for damage caused by overheating
=> inform the customer service
Please note* lines highlighted in yellow contain the changed assignment of the fault numbers: valid from Index 4/12, 6/12, 4/12A, 6/12A
Please note* lines highlighted in pale orange contain the changed assignment of the fault numbers: valid from Index 4/11, 6/11
Please note lines highlighted in light green contain the revised fault numbers: valid for all versions
150 l,s,s,l s,l,l,s air temperature switch over-temperature electronic blocked: – check the heating system – check / replace the water temperature switch replace electronic PCB
or water temperature switch over-temperature – because the air temperature switch for over-heating damage and water temperature sensor
and / or water temperature switch opened – check the thermostat plate / – check / replace the air temperature switch /
during operation. air temperature switch / sensor and cable
air temperature sensor – check / replace the circulating air motor
for damage caused by overheating
=> inform the customer service
150* l,s,s,l s,l,l,s air temperature switch over-temperature or fault: – check the heating system – check / replace the water temperature switch replace electronic PCB
water temperature switch over-temperature – because the air temperature switch for over-heating damage and water temperature sensor
and / or water temperature switch opened – check the thermostat plate / – check / replace the air temperature switch /
during operation. air temperature switch / sensor and cable
air temperature sensor – check / replace the circulating air motor
for damage caused by overheating
=> inform the customer service
151 l,s,s,l s,l,l,l unassigned recheck flash code
152 l,s,s,l l,s,s,s unassigned recheck flash code
153 l,s,s,l l,s,s,l unassigned recheck flash code
154 l,s,s,l l,s,l,s unassigned recheck flash code
155 l,s,s,l l,s,l,l unassigned recheck flash code
156 l,s,s,l l,l,s,s unassigned recheck flash code
157 l,s,s,l l,l,s,l unassigned recheck flash code
158 l,s,s,l l,l,l,s unassigned recheck flash code
159 l,s,s,l l,l,l,l unassigned recheck flash code
160 l,s,l,s s,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
161 l,s,l,s s,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
162 l,s,l,s s,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
163 l,s,l,s s,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
164 l,s,l,s s,l,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
165 l,s,l,s s,l,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
166 l,s,l,s s,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
167 l,s,l,s s,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
168 l,s,l,s l,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
169 l,s,l,s l,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
170 l,s,l,s l,s,l,s voltage fluctuation power supply not constant apply 12 V power supply replace electronics
171 l,s,l,s l,s,l,l failure due to ignition procedure ignition spark interfering with electronics ignitor must have orange label, otherwise check ignitor / flame rectification electrode replace electronic PCB
replace ignitor cable for damage / replace
172 l,s,l,s l,l,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
173 l,s,l,s l,l,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
174 l,s,l,s l,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
175 l,s,l,s l,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
176 l,s,l,l s,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
177 l,s,l,l s,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
178 l,s,l,l s,s,l,s failure due to ignition procedure ignition spark interfering with electronics install earth cable, – check ignitor / flame rectification electrode replace the old ignitor with a new one
part. no.: 34020-57000 cable for damage / replace with a blue label and red point or a
(see also service info CB_110925) – check / adjust plug distances blue label and Index 05
179 l,s,l,l s,s,l,l unassigned recheck flash code
Please note* lines highlighted in yellow contain the changed assignment of the fault numbers: valid from Index 4/12, 6/12, 4/12A, 6/12A
Please note* lines highlighted in pale orange contain the changed assignment of the fault numbers: valid from Index 4/11, 6/11
Please note lines highlighted in light green contain the revised fault numbers: valid for all versions
180 l,s,l,l s,l,s,s unassigned recheck flash code
181 l,s,l,l s,l,s,l unassigned recheck flash code
182 l,s,l,l s,l,l,s unassigned recheck flash code
183 l,s,l,l s,l,l,l unassigned recheck flash code
184 l,s,l,l l,s,s,s combustion air temperature sensor electronics blocked due to operational check heater for damage due to overheating – check / replace combustion air temperature replace electronic PCB
overheating combustion air temperature sensor sensor and cable harness
overheating or combustion air temperature – check / replace warm air motor
sensor short-circuit – check gas supply
185 l,s,l,l l,s,s,l unassigned recheck flash code
186 l,s,l,l l,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
187 l,s,l,l l,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
188 l,s,l,l l,l,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
189 l,s,l,l l,l,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
190 l,s,l,l l,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
191 l,s,l,l l,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
192 l,l,s,s s,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
193 l,l,s,s s,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
194 l,l,s,s s,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
195 l,l,s,s s,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
196 l,l,s,s s,l,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
197 l,l,s,s s,l,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
198 l,l,s,s s,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
199 l,l,s,s s,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
200 l,l,s,s l,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
201 l,l,s,s l,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
202 l,l,k,k l,k,l,k – flame not detected – flame out or not detected (error may only – check gas supply install earth cable, – check flue system
occur after 3 – 5 minutes) part. no.: 34020-57000 – replace the ignition plugs
– poor earth or battery earth to the minus – ground connection from the supply voltage is – check earth connection of supply voltage (see also service info CB_110925) – replace electronic PCB
terminal Combi defective poor or does not exist – check installation of solenoid valve
– magnetic valve nozzle pipe canted
203 l,l,s,s l,s,l,l flame not expected ionization voltage present in standby mode check solenoid valve replace electronic PCB
(stuck in open position)
204 l,l,s,s l,l,s,s unassigned recheck flash code
205 l,l,s,s l,l,s,l unassigned recheck flash code
206 l,l,s,s l,l,l,s dirty supply voltage AC components in supply voltage check supply voltage, AC components also only operate heater with battery replace electronic PCB
possible through power supply units or solar
systems
207 l,l,s,s l,l,l,l dirty supply voltage AC components in supply voltage check supply voltage, AC components also only operate heater with battery replace electronic PCB
possible through power supply units or solar
systems
208 l,l,s,l s,s,s,s combustion air motor running too slowly combustion air motor running too slowly or replace electronic PCB replace combustion air motor
outside tolerance range (if the Index is lower than 4/12, 6/12)
209 l,l,s,l s,s,s,l combustion air motor running too fast combustion air motor running too fast or ignitor must have orange label, otherwise check ignitor / flame rectification electrode replace combustion air motor and / or
outside tolerance range replace ignitor cable for damage / replace electronic PCB
Ignition spark interfering with electronics
210 l,l,s,l s,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
Please note* lines highlighted in yellow contain the changed assignment of the fault numbers: valid from Index 4/12, 6/12, 4/12A, 6/12A
Please note* lines highlighted in pale orange contain the changed assignment of the fault numbers: valid from Index 4/11, 6/11
Please note lines highlighted in light green contain the revised fault numbers: valid for all versions
211 l,l,s,l s,s,l,l combustion air motor running at incorrect combustion air motor running at wrong speed / check gas supply check flue system – replace ignition plugs
speed flame unstable – replace electronic PCB
212 l,l,s,l s,l,s,s unassigned recheck flash code
213 l,l,s,l s,l,s,l unassigned recheck flash code
214 l,l,s,l s,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
215 l,l,s,l s,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
216 l,l,s,l l,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
217 l,l,s,l l,s,s,l electronic defective or failure in electronic PCB check / replace cable harness replace combustion air motor replace electronic PCB
combustion air motor running at incorrect combustion air motor defective
speed cable harness defective
218 l,l,s,l l,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
219 l,l,s,l l,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
220 l,l,s,l l,l,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
221 l,l,s,l l,l,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
222 l,l,s,l l,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
223 l,l,s,l l,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
224 l,l,l,s s,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
225 l,l,l,s s,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
226 l,l,l,s s,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
227 l,l,l,s s,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
228 l,l,l,s s,l,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
229 l,l,l,s s,l,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
230 l,l,l,s s,l,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
231 l,l,l,s s,l,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
232 l,l,l,s l,s,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
233 l,l,l,s l,s,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
234 l,l,l,s l,s,l,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
235 l,l,l,s l,s,l,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
236 l,l,l,s l,l,s,s electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
237 l,l,l,s l,l,s,l electronic fault failure in electronic PCB recheck flash code restart heater replace electronic PCB
238 l,l,l,s l,l,l,s combustion air temperature sensor electronic blocked: check heater for damage due to overheating – check / replace combustion air temperature replace electronic PCB
overheating – because the combustion air temperature sensor and cable harness
sensor became too hot during operation due to – check / replace warm air motor
over-heating
– due to a short-circuit of the combustion air
temperature sensor
Please note* lines highlighted in yellow contain the changed assignment of the fault numbers: valid from Index 4/12, 6/12, 4/12A, 6/12A
Please note* lines highlighted in pale orange contain the changed assignment of the fault numbers: valid from Index 4/11, 6/11
Please note lines highlighted in light green contain the revised fault numbers: valid for all versions
239 l,l,l,s l,l,l,l water temperature switch over-temperatureelectronic blocked: – check the heating system – check / replace the water temperature switch replace electronic PCB
or air temperature switch over-temperature
– because the water temperature switch for over-heating damage and water temperature sensor
and / or air temperature switch opened during – check the thermostat plate / – check / replace the air temperature switch /
operation. air temperature switch / sensor and cable
air temperature sensor – check / replace the circulating air motor
for damage caused by overheating
=> inform the customer service
239* l,l,l,s l,l,l,l water temperature switch over-temperature fault: – check the heating system – check / replace the water temperature switch replace electronic PCB
or air temperature switch over-temperature – because the water temperature switch for over-heating damage and water temperature sensor
and / or air temperature switch opened during – check the thermostat plate / – check / replace the air temperature switch /
operation. air temperature switch / sensor and cable
air temperature sensor – check / replace the circulating air motor
for damage caused by overheating
=> inform the customer service
240 l,l,l,l s,s,s,s air temperature switch over-temperature electronic blocked: – check the heating system – check / replace the water temperature switch replace electronic PCB
or water temperature switch over-temperature – because the air temperature switch for over-heating damage and water temperature sensor
and / or water temperature switch opened – check the thermostat plate / – check / replace the air temperature switch /
during operation. air temperature switch / sensor and cable
air temperature sensor – check / replace the circulating air motor
for damage caused by overheating
=> inform the customer service
240* l,l,l,l s,s,s,s air temperature switch over-temperature fault: – check the heating system – check / replace the water temperature switch replace electronic PCB
or water temperature switch over-temperature – because the air temperature switch for over-heating damage and water temperature sensor
and / or water temperature switch opened – check the thermostat plate / – check / replace the air temperature switch /
during operation. air temperature switch / sensor and cable
air temperature sensor – check / replace the circulating air motor
for damage caused by overheating
=> inform the customer service
241 l,l,l,l s,s,s,l unassigned recheck flash code
242 l,l,l,l s,s,l,s unassigned recheck flash code
243 l,l,l,l s,s,l,l unassigned recheck flash code
244 l,l,l,l s,l,s,s unassigned recheck flash code
245 l,l,l,l s,l,s,l unassigned recheck flash code
246 l,l,l,l s,l,l,s unassigned recheck flash code
247 l,l,l,l s,l,l,l unassigned recheck flash code
248 l,l,l,l l,s,s,s unassigned recheck flash code
249 l,l,l,l l,s,s,l unassigned recheck flash code
250 l,l,l,l l,s,l,s unassigned recheck flash code
251 l,l,l,l l,s,l,l unassigned recheck flash code
252 l,l,l,l l,l,s,s unassigned recheck flash code
253 l,l,l,l l,l,s,l unassigned recheck flash code
254 l,l,l,l l,l,l,s unassigned recheck flash code
255 l,l,l,l l,l,l,l unassigned recheck flash code