0% found this document useful (0 votes)
14 views2 pages

Top Slab

The document outlines the design specifications for a top slab, including material properties, dimensions, and reinforcement requirements. It provides detailed calculations for flexural and shear design, ensuring compliance with relevant standards. Key values include a design moment of 5.74 kN-m, a design shear of 13.13 kN, and an area of reinforcement provided of 251.2 mm².
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views2 pages

Top Slab

The document outlines the design specifications for a top slab, including material properties, dimensions, and reinforcement requirements. It provides detailed calculations for flexural and shear design, ensuring compliance with relevant standards. Key values include a design moment of 5.74 kN-m, a design shear of 13.13 kN, and an area of reinforcement provided of 251.2 mm².
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

DESIGN OF TOP SLAB

DATA VALUE UNITS Reference


Type of Fiber Used GLASS
Concrete Exposed To Soil And Water NO
Cube Commpressive Strength fck 20 N/mm2
810 2
Ultimate Strength Of Rebar ffu* N/mm
65000 2
Modulus Of Elasticity Ef N/mm
Width b 1000 mm
Depth C D 150 mm
Design Moment Mu 5.74 kN-m
Design Shear Vu 13.13 kN
Allowable Crack Width 0.7 mm
Maximum Concrete Strain εcu 0.003 440.1R, Cl. 7.1.2
Clear Cover 40 mm
Diameter Of Main Bar 8 mm
Spacing Between Bars 200 mm
2
Area of Reinforcement Provided Af,pro 251.2 mm
Moment Capacity Of The Section φ*Mn 7.750 kN-m
Cylinder Strength Of Concrete f' c 16 N/mm2
Environment Reduction Factor CE 0.8 440.1R, Table 6.2
648 2
Design Strength Of Rebar ffu N/mm 440.1R, Eq. (6.2a)
β1 0.85
Effective Depth Of Member d 96 mm
Ef*εcu 195
ρfb 0.0041 440.1R, Eq. (7.2.1b)

Design for Flexure

Initial Assumption Tension Controlled


Strength Reduction Factor φ 0.55 440.1R, Eq. (7.2.3)

Depth Of Neutral Axis cb 22.21 mm 440.1R, Eq. (7.2.2h)

Area of Reinforcement Required Af,reqd 186.13 mm2 440.1R, Eq. (7.2.2g)

% Reinforcement Required ρf 0.0019 440.1R, Eq. (7.2.1a)

Reinforcement Ratio ρf /ρ fb 0.47

245.45 2
Minimum Area Of Reinforcement Required Af,min mm 440.1R, Eq. (7.2.4),Eq. (9.1)
Area of Reinforcement Required Af,reqd 245.45 mm2
OK

Horizon Design Consultants


Check
% Reinforcement Provided ρf 0.0026 440.1R, Eq. (7.2.1a)
Tensile Strength At Ultimate Condition ff 648.00 440.1R, Eq. (6.2a)

Reinforcement Ratio ρf /ρ fb 0.63


Type of Faliure TENSION CONTROLLED
Strength Reduction Factor φ 0.55 440.1R, Eq. (7.2.3)

Tension Controlled
Depth Of Neutral Axis cb 22.21 mm 440.1R, Eq. (7.2.2h)

Moment Capacity Mn 14.09 kNm 440.1R, Eq. (7.2.2g)

Reduced Moment Capacity φMn 7.75 kNm


OK
Compression Controlled
251.20 2
Area of Reinforcement Provided Af,pro mm
% Reinforcement Provided ρf 0.0026 440.1R, Eq. (7.2.1a)
ρf /ρ fb 0.63
Stress in FRP Bar
2
f 585.04 N/mm 440.1R, Eq. (7.2.2d)
OK

Moment Capacity Mn 13.31 kNm

Reduced Moment Capacity φMn 7.32 kNm


OK
Transverse Reinforement
Min Steel ρf 135.74 mm2
7 250 mm
2
Af,pro 153.9 mm
Design for Shear
Modulus of Elasticity of Concrete Ec 22360.68 N/mm2

Modular Ratio nf 2.91


ρfnf 0.008
k 0.116 440.1R, Eq. (7.3.2.2b)
Reduced Shear Capacity φVn 13.36 440.1R, Eq. (8.2b)
OK

Horizon Design Consultants