EARTHQUAKE ENGINEERING
Technical Report #4
Submitted to:
Engr. Jose E. Elfa Jr.
Submitted by:
Gallaza, Karen T.
Ebaldone, Jona M.
Florendo, Jessa Mae A.
BSCE4-EC3
November 6,2023
3.1m 8.0m 8.0m 8.0m 4.65m
3.2m
4.8m
1.8m
A1 A2 A3 A4 A5
A B C D E F
GL 1
•S/L=1.8/3.1=0.58 two-way slab •Weight of Exterior Wall
•S/L=1.8/8.0=0.225 one-way slab Wew=(3.30)(0.150)(26.7 kN/m³)
•S/L=1.8/4.65=0.39 one-way slab Wew=13.22 kN/m
DEADLOADS •Weight of Interior Wall
•Thickness of Slab Wiw={(19.6 kN/m³)+ 2 (0.29.)}(3.30)(0.150)
s=0.13m Wiw=9.94 kN/m
Ws=(0.13)(23.6 kN/m³)
Ws=3.07 kN/m² •Weight of Hallway Railings
Whr=(0.10)(1.7)(19.6 kN/m³)
•Weight of Utilities and Ceiling Whr= 3.33 kN/m
Wuc=0.2 kPa+0.2kPa
Wuc=0.4 kPa •Weight of Common Deadload
Wdl=3.07+0.4+1.10
•Weight of Floor finishes Wdl= 4.57 kN/m²
600mm×600mm Homogeneous tiles
Wff=1.10 kPa LIVELOADS
Hallway=7.2 kPa
•Weight of Beam LL=7.2 kN/m²
Wb=(0.3)(0.6)(23.6 kN/m³)
Wb=4.25 kN/m
• GL1-A1
Wt. of DEADLOAD Wt. of LIVELOAD
WDL=(4.57)(1.8)/3 [3-(0.58)²/2] WLL=(7.2)(1.8)/3 3-(0.58)²/2
WDL=3.65 kN/m WLL=5.57 kN/m
+WHR=3.33 kN/m
+Wb=4.25 kN/m UNIFORM LOAD
+Wew=13.22 kN/m UL=1.2(24.45)+1.6(5.75)
WTDL=24.45 kN/m UL=38.54 kN/m
• GL1-A2=A3=A4 Wb=4.25 kN/m
Wt. of DEADLOAD WTDL=11.69 kN/m
WDL=(4.57)(1.8)/2
WDL=4.11 kN/m Wt. of LIVELOAD
+Whr=3.33 kN/m Wll=(7.2)(1.8)/2
Wll=6.48 kN/m +Whr=3.33 kN/m
+Wew=13.22 kN/m
UNIFORM LOAD WTDL=30.60 kN/m
UL=1.2(11.69)+1.6(6.48)
UL=24.40 kN/m Wt. of LIVELOAD
Wll=(7.2)(1.8)/2=6.48 kN/m
• GL1-A5
Wt. of DEADLOAD UNIFORM LOAD
WDL=(4.57)(1.8)/2 UL=1.2(30.60)+1.6(6.48 kN/m)
WDL=4.11 kN/m UL=47.09 kN/m
+Wiw=9.94 kN/m
ROOF LOADS E.) Weight of Roofing Materials
Wrm= 0.2x48.288
(i) Span of Truss = 9.8 Wrm= 9.66kN
(ii) Spacing of Truss = 9.6 F.) Weight of Purlin
(iii) Rise of Truss = 1.52 Wp= 0.6x47.04
(iv) Height of Truss Ground Level = 10.3
Wp= 28.22kN
(v) ACC Sheet @ 0.2 kN/m² are used as
roof covering
(vi) Weight of Purling and other Fixtures = G.) Self Weight of Truss
0.6 kN/m² = 10[span/3+5]N/m3
(vii) Total Numbers of Panels = 12 = 10[9.8/3+5]
=82.67N/m3
A.) Angle of Roof Trusses Wt= (82.67)(47.04)
Tanθ=1.52/4.8 Wt= 3.888N/m3
θ=17.57º
H.) Weight of Wing Bearing
B.) Length of Principal Rafter Wwb= 0.17x47.04
P.R.= √(1.52)2+(4.8)2 Wwb= 7.997kN
P.R.= 5.03m
I.) Total Deadload
C.) Half Plan Area TDL= 9.66+ 28.22+ 82.67+ 3.888+ 7.997+
HPA= L/2*spacing of truss 46.08
= (9.8/ 2)(9.6) TDL= 178.515kN
HPA= 47.04m
J.) Liveload
D.) Half Slope Area LL= (1.0)(4.8)(9.6)
HSA= 5.03x9.6 LL= 46.08kN
HSA= 48.288m2
K.) Uniform Load
UL= 1.2(178.515)+1.6(46.08)
w=287.25 UL=
kN 287.95 kN/m
1.5m
329.78 kN
Earthquake
Roof
Load
2.70m
1487.89 kN w=720.00 kN
3rd Floor
Occupancy: IV
2.70m
Importance
2438.83 kN Factor: I=1.00 w=1180.17Seismic
kN Zone: 4
2nd Floor
2.70m
WT=2187.42 kN
Seismic Zone Factor, z= 0.40
Soil Type: SD
STMF= 6.5
Ω= 3.0
Distance= 10 km.
Seismic Coefficient:
Cv =0.64 Nv ; Nv= 1.2
Cv = (0.64)(1.2) = 0.768
Ca = 0.44 Na ; Na= 1.0
Ca = (0.44)(1.0) = 0.44
hn= 2.7+2.7+2.7+1.5 = 9.6m
T = 0.0731 (9.6)3/4 = 4.0
w= 287.25+ 720 + 1180.17 = 2187.42 kN
Vreq’d = CvIw = (0.768)(1.0)(2187.42) = 42.598 kN Ft = (0.0731)(4)(6015.41)
RT (8.00)(4.0) Ft = 1758.91
Vmax = 25CaIw = (25)(0.44)(2187.42) = 6015.41 kN Vmin = 0.8zNvIw = (0.8)(0.4)(1.0)(2187.42) = 209.99 kN
R (4.0) R (4.0)
Level Weight Height
Roof 287.25 1.50 430.88
3 Floor
rd
720 2.70 1944
2nd Floor 1180.17 2.70 3186.46
Total: 5561.34
Roof = (6015.41-1758.91)(430.88) = 329.78 kN 2nd Floor = (6015.41-1758.91)(3186.46) = 2438.83 kN
(5561.34) (5561.34)
3rd Floor = (6015.41-1758.91)(1944) = 1487.89 kN
(5561.34)
330kN
V 2V 2V 2V 2V V
1488kN
2439kN
425.7kN 851.4kN 851.4kN 851.4kN 851.4kN
425.7kN
574kN-m 1149kN-m 1149kN-m
574kN-m
1149kN-m 1149kN-m
744kN 455.25kN 205.25kN 205.25kN 207.25kN 496kN
330-10V=0
V= 33kN; 2V= 66kN
330+1488-10V=0
V=181.8kN; 2V=363.6kN
330+1488+2439-10V=0
V= 425.7kN; 2V=851.4kN