0% found this document useful (0 votes)
30 views17 pages

Data Sheet

The HCVR-3 is a UL Listed and FM Approved conventional releasing fire alarm control panel with three detection zones, allowing for flexible configuration of releasing options. It features a simple menu for programming, an LCD display for countdown timers, and compatibility with various detection devices and releasing valves. The panel supports configurable delays and durations for releasing, making it installer-friendly and versatile for fire safety applications.

Uploaded by

Sameera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views17 pages

Data Sheet

The HCVR-3 is a UL Listed and FM Approved conventional releasing fire alarm control panel with three detection zones, allowing for flexible configuration of releasing options. It features a simple menu for programming, an LCD display for countdown timers, and compatibility with various detection devices and releasing valves. The panel supports configurable delays and durations for releasing, making it installer-friendly and versatile for fire safety applications.

Uploaded by

Sameera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

HCVR-3 - CONVENTIONAL RELEASING FIRE ALARM CONTROL PANEL

STANDARD FEATURES

 UL 864 Listed and FM Approved


 Three detection zones
 Any single zone or any combination of zones can be
configured to release
 Fully programmable using simple menu options
 Simple, single board construction
 Installer friendly
DESCRIPTION
 Compatible with wide range of detection devices
 Configurable first stage NAC delays
The HCVR-3 is a 3 zone conventional releasing fire
alarm control panel that is UL Listed and FM Approved  Configurable detection delays
for releasing.
 Built-in Manual Release switch and separate circuit
The HCVR-3 can be configured to activate releasing by
a single zone or combination of any two zones. The  Compatible with FirePro Xtinguish™
LCD display is used to show the countdown timer  Compatible with various releasing valves
during activation of the releasing sequence.
 Configurable releasing delays up to 60 seconds in 5
The HCVR-3 is fully programmable using simple menu second intervals
options. The panel is a single board construction which
provides an easy replacement solution. It is also  Configurable releasing duration up to 5 minutes in 5
second intervals
compatible with a wide range of devices.
 Releasing countdown timer displayed on the LCD
 Supports up to seven HCVR-SDU or HCVR-AB
 Built-in relays for Fire, Trouble, Stage 1, Stage 2,
Extract and Local Fire

PRODUCT LISTINGS

California State
Fire Marshal
7165-0410:0206
S6468 3046396

Specifications subject to change without notice. Continued on back.

Hochiki America Corporation Find latest revision at www.hochiki.com


7051 Village Drive, Suite 100, Buena Park, CA 90621-2268
Phone: 714-522-2246 Fax: 714-522-2268
Technical Support: 800-845-6692 or [email protected] F0154 09/2016
HCVR-3 - CONVENTIONAL RELEASING FIRE ALARM CONTROL PANEL
SPECIFICATIONS
Supply Voltage 115VAC (50hz/60hz) or 230VAC (50hz/60hz)
Power Supply DC Rating 24VDC 3 Amps total including battery charging
Mains Supply Fuse 1.6 Amps 250VAC, slow-blow, 5 x 20mm
Dimensions 14.5" (368.3mm)W x 12.2" (309.88mm)H x 3.5" (88.9mm)D
Weight 12.3 lbs.
Color Red or gray
Material 1.2mm mild steel
Max. Battery Size 7Ah 12V (2 per panel)
RS-485 Serial Bus Maximum line impedance 120 Ohms
Trouble Contact Rating 30VDC 1 Amp
Local Fire Contact Rating 30VDC 1 Amp
Fire Contact Rating 30VDC 1 Amp
1st Stage Contact Rating 30VDC 1 Amp
2nd Stage Contact Rating 30VDC 1 Amp
EXTING Contact Rating 30VDC 1 Amp contacts for (NO) and ©
EXTING Contact Rating 18 to 28VDC 1 Amp mas load for 5 minutes and voltage reversing DC
NAC Output Rating 0.5 Amp per output
Detection Zone End of line resistor 6K8 Ohms 5% resistor
NAC Output 10K Ohms 5% resistor
Stand by Current 86 mA
Alarm Current 620 mA
Operating Humidity 93% (non condensing)
Operating Temperature -5°C to +40°C

HOCHIKI AMERICA COMPATIBLE DEVICES


MODEL DESCRIPTION MAX
PANEL ACCESSORIES
HCVR-SDU Remote Status Display Unit 7
HSVR-AB Ancillary Board 7
HCVR-SQA Sequential Activator 20
HCVR-DS Disconnect Switch 1
DETECTORS
SLR-24H Photoelectric Smoke Detector w/heat 20 per zone
SLR-835 Photoelectric 8-35V Smoke Detector 20 per zone
SLR-835/-835W Photoelectric 8-35V Smoke Detector 20 per zone
SLR-835-BH-2W Photoelectric 8-35V Smoke Detector w/heat 20 per zone
SLV-24V/-24/-24N Photoelectric Smoke Detector 20 per zone
SIJ-24 Ionization Smoke Detector 20 per zone
DCD-135 135° Fixed Temperature Rate of Rise Heat Detector 20 per zone
DCD-190 190° Fixed Temperature Rate of Rise Heat Detector 20 per zone
BASES
NS6-220 6" base, 43mA draw, 24V 20
NS4-220 4" base, 43mA draw, 24V 20
PULL STATION/ABORT SWITCH
HPS-SAK/HPS-DAH/HPS-SAH/HPS-DAK Conventional Manual Pull Station for Fire Suppression Release n/a
HCVR-AS Abort Switch n/a
RELEASING VALVES
HV2185328 ASCO Solenoid 1
8210G207 ASCO Solenoid 1
11601 Viking Solenoid 1
11602 Viking Solenoid 1
11592 Viking Solenoid 1
11591 Viking Solenoid 1
11596 Viking Solenoid 1
11595 Viking Solenoid 1
2823A-2NB-A4F6 Snap-tite Solenoid 1
EA45 (510006) Sevo Systems Solenoid 1
K-45-8017 Kidde Solenoid (equivalent to 486500-01) 1
B6793-859 Kidde Solenoid (equivalent to 81-100000-001) 1
753-E Series Victaulic Solenoid 1
305350 Ci IS8B Fire Eater Solenoid 1
305451 Ci IS8B Fire Eater Solenoid 1

Hochiki America Corporation HCVR-3 Specifications subject to change without notice.


Your Safety, Our Technology

SOC-E3N(WHT)

SOC-E3N
Conventional Photoelectric Smoke Detector

Features
 Removable, High Performance chamber
 Automatic Sensitivity Window Verification (ASWV) – Drift Compensation Technology

Remote Indicator output
SOC-E3N

Wide voltage range (9.5 ~ 30 V dc)

Low profile design with one piece outer cover

Single fire LED - 360° viewing

Range of mounting bases

Approved by LPCB

Description Listings / Approvals


The SOC-E3N is a Photoelectric Smoke Detector, which is fully compatible
with the majority of existing Conventional systems. The SOC-E3N incorporates
Hochiki’s unique High Performance photoelectric smoke chamber removing the
need to use Ionisation Detectors in the majority of applications.

‘AFVW’ Drift Compensation technology is incorporated to ensure the Detector


is operating at its optimum sensitivity and therefore reducing potential false
alarms. If the contamination limit is exceeded then the integral red LED will flash
once every three seconds to give a visual warning. The smoke chamber is easily
removed or replaced for cleaning and utilises a unique baffle design which
allows smoke to enter the chamber whilst keeping out ambient light.

Specification

Approvals LPCB EN54: Part 7

Operating Voltage 12V – 30 V dc

Quiescent Current (typ) 35 µA

Maximum Current Alarm 40 mA

Out of Sensitivity Current (Red Flashing LED) 120 µA

Remote Indicator Drive 20 mA (max)

Operating Temperature Range -10 °C to + 50 °C

Storage Temperature Range -30 °C to + 60 °C

Maximum Humidity 95%RH - Non Condensing (at 40 °C)

Ingress Protection Rating IP42

Colour / Case Material Ivory or White / ABS

Weight (g) 95 (excluding base)

Diameter (mm) / Height (mm) 100 / 45

For further information visit www.hochikieurope.com/cdx


Your Safety, Our Technology

Specification

YBN-R/6 , YBN-R/6SK
Compatible Bases
YBO-R/6R, YBO-R/6RS, YBO-R/6RN, YBO-R/6PA

Base Fixing Centres (mm) 48 ~ 74

Ordering Codes

Product Part Number

Detector SOC-E3N
SOC-E3N(WHT)

Replacement Chamber SOC REPLACEMENT CHAMBER

For further information visit www.hochikieurope.com/cdx


Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice.
Although every effort has been made to ensure the accuracy of the information contained in this document it is not
warranted or represented by Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Electronics Free
Mounting Base
YBN-R/6
Features
 Integral remote indicator output
 Low Profile, only 8 mm
 Rugged design and electronics free
 Quick connections via square cable
clamps
 Accepts 2.5 mm2 cables
 Bayonet slot, low insertion force for
detectors
 Also available in white or black

Description
Model YBN-R/6 is a Conventional Detector Mounting Base associated with the CDX Range
of Detectors and is fully compatible with the majority of existing conventional fire alarm
control panels.
It is supplied with square cable clamps for secure and reliable cable termination but the
base does not provide line continuity during detector removal, therefore if Call Points are
being used then these should be wired onto the zone first. The integrated third terminal
provides remote indicator output.

Specification
YBN-R/6
Ordering Code YBN-R/6(WHT)
YBN-R/6(BLK)
Operating Voltage 9.5 – 30 V dc
Operating Temperature Range -10 C to + 50 C
Storage Temperature Range -30 C to + 60 C
Maximum Humidity 95%RH - Non Condensing (at 40 C)
Colour / Material Ivory or White / ABS
Weight (g) / Diameter (mm) / Height (mm) 51 / 100 / 8
Fixing Centres (mm) 48 ~ 74

Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although
every effort has been made to ensure the accuracy of the information contained in this document it is not warranted or
represented by Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Indoor Specialist
Activation Devices
Miniature & Shrouded Pushbutton models
9300 + 9400

> Product Benefits


• A range of Miniature and shrouded
push switch devices available,

• Suitable for Fire, Security & Other


Specialist Applications

• Variety of colours and markings

Miniature push button

Shrouded push button

Product Overview
The KAC Class 9000 range of devices provides you with the most comprehensive range of
switching product solutions for fire, security and other specialist applications.

All products comprise a main housing and escutcheon plate. The switching device is fitted to
the plate, which simply snaps into the main housing and is permanently located into place by
fixing screws.

As with our market leading range of call points, all switching devices can be supplied in
our core colours of red, green, white, yellow and blue. There are also numerous function
marking options available to meet your specific requirements.

The miniature push switch family can be supplied with the following options: -

Momentary Action – contacts transferring only while the button is depressed.


Latching – a push/push action; the contacts transfer when the button is pressed and stay
transferred until the button is pressed again.
Terminated – 120mm long 16/0.2mm2 cable is soldered to the six terminals of the switching
device. Shrouded 100mm 1 amp 32/0.2mm2 cable is soldered to the 3 terminals.
Non-terminated – no cables are connected to the switching device.

From these options four principle versions can be supplied: -

• Momentary action, non terminated


• Momentary action, terminated
• Latching, non terminated
• Latching, terminated

A shrouded push button switch product is also available providing single pole changeover
switching with a momentary action. PB-1
Rev. No. 4
Electrical Specification

Connection Details: See figures 1 & 2
Cable Terminals: See figure 3
Maximum Voltage: 240VAC or 24VDC
Current Rating
Miniature: 0.5 Amps @ 240VAC,
1Amps @ 24VDC
Current Rating
Shrouded: 6Amps @ 240VAC/24VDC
Fig.1

Environmental Specification Fig.2


Humidity: 0-95% non-condensing
Operating Temperature: -25oC to +55oC
Storage Temperature: -25oC to +55oC
Ingress Protection (IP) Rating: IP24D
For RoHS, WEEE & REACH data please see www.kac.co.uk

R B R B R B R B

Mechanical Specification
'9101' E L '9103' E L E L E L '9201' A3
D U D U D U D U
& E E E E
A2
A1
'9102'
B6

Material: OFF
ABS OFF OFF OFF 'A'
B5
B4

Weight: 120g Flush, Fig.3


'9202' B4 180g
B5 Surface
'9203'
A2
A3 '9300' NC Yellow '9401' NC
Red COM
Colour: Red, A1 NO Blue COM Yellow
NC Yellow Red
Green, B5
B6
Red COM
NO Blue
NO
Blue
'B' 'C' B4
A1
White,
A2
Colour codes relate to the flying leads for terminated models
D
Yellow,
STANDARD 9100 TYPE OPTIONS (KEY SWITCH)
9101 -2 position, Key removable in both positions
STANDARD 9200 TYPE OPTIONS (ROCKER SWITCH)
9201- Double pole changeover
Colour codes relate to the flying leads for terminated models
STANDARD 9300 TYPE OPTIONS (PUSH BUTTON)
Non-terminated
9102 -2 position, Key retained in one position 9202- Double pole single throw, red neon indicator. Type 9301
9301,Momentary action

Blue,
9103 -3 position, Key removable in all positions
ELECTRICAL DATA
9203- Double pole changeover with centre off.
ELECTRICAL DATA
Type 9303, Latching
Terminated TYPE 9401 METHODS OF MOUNTING
Flush Installations:
CLASS
All 9100 type Call Points have silver switch contacts All 9200 type Call Points have silver switch contacts. Type 9302, Momentary action Hinged
Orange
(PUSH BUTTON)
with 5 milliohm contact resistance. Maximum Voltage: 250Vac 50Hz Type 9304
9304,Latching 9401 - Momentary action, single pole change over. 'Call point only' fits directly to a U.K. A transpa
Maximum Voltage: 250Vac 50Hz Resistive load: 16A at 250Vac ELECTRICAL DATA ELECTRICAL DATA switch/socket box. A minimum box hinged c
Resistive load: 10A at 12vdc / 2A at 250vac Inductive load: 6A at 250Vac. All 9300 type Call Points have gold clad 9401 type Call Point has silver switch contacts with depth of 35mm is recommended. protectio
Inductive load: 3.6A at 12Vdc Operating Temperature Range: silver switch contacts with 50 milliohm 50 milliohm contact resistance. operation
Termination cables limit current to 6A max. -20°C to +70°C maximum contact resistance. Maximum Voltage: 250 Vac 50Hz Surface Installation:
Operating Temperature range: Switch type Maximum voltage: 250Vac 50Hz Resistive load: 8A at 250Vac There is a choice of plastic or metal
-20°C to + 55°C The 2600 Rocker Switch series, manufactured Resistive load: 0.5A at 220Vac 8A at 50Vac surface mounting boxes. Spacer
Switch type by APEM COMPONENTS. 1A at 110Vac or 30Vdc illustrati
TOK P2/3F rotary key switch with 5 disc CABLE TERMINATION 1A at 24Vdc Termination cables limit current to 6A max. Plastic Box-as SR: Snap fits

Ordering Information
tumbler lock , type S425 . (BURGESS TOK SWITCH) It is intended that the installer connects cables Operating temperature range: Operating Temperature range: The pack box has a tear off template Box SR a
CABLE TERMINATION to the switch by using the screw/clamp type -25°C to +55°C -25°to +70°C for locating cable entry holes. to its usa
All 9100 type call points are supplied with lengths terminals provided. Switch type Switch type See illustration 'A' below.
of 120mm x 32/0.2mm cable soldered to each switch Diagram 'A' shows the contact IDEC 'A' series miniature push button. OTEHALL ZERO PLUS type shrouded push switch. SPECIAL
terminal. It is intended that the installer fits a suitable arrangement for 9201 double CABLE TERMINATION CABLE TERMINATION Metal box-as MR: in White
It is intended that the installer connects cables toAll 9400 type Call Points are supplied with lengths Cable access holes suitable for 20mm
Model
terminal block to these cables.
Description
Contact arrangement 9101 and 9102 types:
pole changeover type switch.
Diagram 'B' shows the contact Mounting
the Call Point by soldering directly to the of 100mm x 32/0.2mm cable soldered to each diameter cable glands or conduit.
All of the
can be s
One pair of contacts normally open, one pair of contacts arrangement for 9202 double pole 2.8mm x 0.5mm connection tags on the rear of switch terminal . It is intended that the installer ations to
normally closed . Operation of switch transfers contacts.
(See Illustration "9101,9102")
single throw, red neon indicator.
Diagram 'C' shows the contact
the switch. Alternatively types 9302/9304 are fits a suitable terminal block to these cables.
provided with 16/0.2mm x 120mm flying leads. Diagram shows switch with push-button
Continuity Link KL1 - Illustration
'B'. For 20mm terminations.
W*9301 Minature, Momentary action, non terminated
Contact arrangement 9103 types:
Both pairs of contacts open in centre
arrangement for 9203 double
pole changeover with centre off. where the;
Flush
Contacts are shown in the circuit diagram above not depressed.

W*9301/S Minature, Momentary action, non terminated


position.One pair closed in each of the
other two positions. (See Illustration "9103") Surface
Button not depressed for Momentary type.
Button out for Latching type.

W*9302 Minature, Momentary action, terminated Flush


W*9302/S Minature, Momentary action, terminated Surface
W*9303 R B Minature,
R Latching,
B R non Bterminated
R B Flush
'9101' E L '9103' E L E L E L '9201' A3
W*9303/S& D U
E
Minature,
D Latching,
U
E
D non Uterminated
E
D U
E A2 Surface
W*9304'9102' Minature, Latching, terminated Flush
A1 A B
B6
W*9304/S Minature, Latching, terminated B5
Surface
W*9403-K013-01OFF Shrouded,OFFMomentaryOFF action, terminated
OFF 'A' Flush
B4

W*9403-K013-01/S Shrouded, Momentary action, terminated Surface


other variations
'9202' B4available
B5 '9203' A3 '9300' NC Yellow
A2
Red COM '9401' NC
A1 NO Blue
* - defines colour, R=red, G=green, W=white, Y=yellow,B6B=blue, A=orange NC Yellow COM Yellow
B5
Red COM Red NO
NO Blue
'B' A1 A2 'C' B4 Blue
To identify the function label please attach word to the end of theColour above part
codes relate codes.
to the flying leads for terminated models

For example WR9203/SR-F222 = ThreeSTANDARD


STANDARD 9100 TYPE OPTIONS (KEY SWITCH)
9101 -2 position, Key removable in both positions
position miniature push button, STANDARD
9200 TYPE OPTIONS (ROCKER SWITCH)
9201- Double pole changeover
red, “House Flame” label
9300 TYPE OPTIONS (PUSH BUTTON)
Non-terminated
D
For available
9103 -3 position,function labels please refer9202-
9102 -2 position, Key retained in one position
Key removable in all positions
toDouble
ourpoledata sheets “FM-RED” and
single throw, red neon indicator.
9203- Double pole changeover with centre off.
“FM-COL”.
Type 9301
9301,Momentary action
Type 9303, Latching
ELECTRICAL DATA ELECTRICAL DATA Terminated CLASS
TYPE 9401 METHODS OF MOUNTING
All 9100 type Call Points have silver switch contacts All 9200 type Call Points have silver switch contacts. Type 9302, Momentary action
(PUSH BUTTON) Flush Installations: Hinged
with 5 milliohm contact resistance. Maximum Voltage: 250Vac 50Hz Type 9304
9304,Latching
9401 - Momentary action, single pole change over. 'Call point only' fits directly to a U.K. A transpa
Maximum Voltage: 250Vac 50Hz Resistive load: 16A at 250Vac ELECTRICAL DATA
ELECTRICAL DATA switch/socket box. A minimum box hinged c
Resistive load: 10A at 12vdc / 2A at 250vac Inductive load: 6A at 250Vac. All 9300 type Call Points have gold clad
Accessories
Inductive load: 3.6A at 12Vdc
Termination cables limit current to 6A max.
Operating Temperature Range:
-20°C to +70°C
silver switch contacts with 50 milliohm
maximum contact resistance.
9401 type Call Point has silver switch contacts with
50 milliohm contact resistance.
depth of 35mm is recommended. protectio
operation
Surface Installation:
Code Operating Temperature range:
-20°C to + 55°C
Description Switch type
The 2600 Rocker Switch series, manufactured
Maximum voltage: 250Vac 50Hz
Resistive load: 0.5A at 220Vac
Maximum Voltage: 250 Vac 50Hz
Resistive load: 8A at 250Vac There is a choice of plastic or metal
surface mounting boxes. Spacer
PS200 Switch type
Plain Hinged Cover by APEM COMPONENTS. 1A at 110Vac 8A at 50Vac

> KAC Alarm Company Ltd


TOK P2/3F rotary key switch with 5 disc CABLE TERMINATION 1A at 24Vdc or 30Vdc illustrati
Termination cables limit current to 6A max. Plastic Box-as SR: Snap fits
tumbler lock , type S425 . (BURGESS TOK SWITCH) It is intended that the installer connects cables Operating temperature range:
Operating Temperature range: The pack box has a tear off template Box SR a
CABLE TERMINATION to the switch by using the screw/clamp type -25°C to +55°C
KAC House, Thornhill Road,
All 9100 type call points are supplied with lengths terminals provided. Switch type -25°to +70°C for locating cable entry holes. to its usa
Switch type See illustration 'A' below.
North Moons Moat, Redditch,
of 120mm x 32/0.2mm cable soldered to each switch
terminal. It is intended that the installer fits a suitable
Diagram 'A' shows the contact
arrangement for 9201 double
IDEC 'A' series miniature push button.
CABLE TERMINATION OTEHALL ZERO PLUS type shrouded push switch. SPECIAL
Metal box-as MR: in White
B98 9ND, United Kingdom
terminal block to these cables.
Contact arrangement 9101 and 9102 types:
pole changeover type switch.
Diagram 'B' shows the contact
It is intended that the installer connects cables toCABLE TERMINATION
the Call Point by soldering directly to the All 9400 type Call Points are supplied with lengths Cable access holes suitable for 20mm All of the
diameter cable glands or conduit.
Tel: +44 (0) 1527 406655
One pair of contacts normally open, one pair of contacts
normally closed . Operation of switch transfers contacts.
arrangement for 9202 double pole 2.8mm x 0.5mm connection tags on the rear of of 100mm x 32/0.2mm cable soldered to each
the switch. Alternatively types 9302/9304 are switch terminal . It is intended that the installer
can be s
ations to
single throw, red neon indicator.
Fax: +44 (0) 1527 406677
(See Illustration "9101,9102") Diagram 'C' shows the contact provided with 16/0.2mm x 120mm flying leads. fits a suitable terminal block to these cables.
Continuity Link KL1 - Illustration
'B'. For 20mm terminations.
Contact arrangement 9103 types: arrangement for 9203 double Contacts are shown in the circuit diagram above Diagram shows switch with push-button
e-mail: [email protected]
Both pairs of contacts open in centre pole changeover with centre off. where the; not depressed.
position.One pair closed in each of the Button not depressed for Momentary type.
other two positions. (See Illustration "9103") Button out for Latching type.

We reserve the right to amend the content of this document without prior notice.

A B
MCP Indoor Call Point Range
Resistor & Clean Contact Model
(Colour Versions)

> Product Benefits


• Unique ‘Plug & Play’ installation
concept

• Total ‘Flex-Ability’ in the choice


of operating element

• Anti-Tamper facility

• Enhanced aesthetics

• Backward compatibility

Product Overview
Installation efficiency, flexibility and full compliance with the latest standards are at the heart of
the new MCP Indoor Call Point range.

Installation time and ultimately cost, are of paramount importance to any fire or security
installer. The MCP range directly reflects this need by providing a unique ‘plug and play’
concept designed specifically to reduce installation time. All new MCP products utilise a
special terminal block, where all initial installation cabling is terminated. This terminal block
is then simply connected to the back of the MCP. Simple, but effective with no re-termination
required and no time wasted.

Both break glass and resettable operating elements can now be used within a manual call
point. To provide you with the greatest ‘flex-ability’, the new MCP range can be configured as
either a break glass or resettable unit by simply changing from one element to another. No
other additional parts or alternative products need to be ordered.

All MCP Indoor Call Point products also help preserve the integrity of the overall system as
illegal removal of the product lid will result in the call point operating and the system going in to
alarm.

The MCP1A product version is supplied with both a resistor and normally open clean contact
electrical options. These options are easily utilised by simply connecting the terminal block
to the required connection in the back of the MCP1 product. A variety of resistor versions are
available, with both 470Ω and 680Ω offered as standard. However, other resistor types can be
provided upon request.

All of our colour products can be supplied with a variety of markings to meet your specific
requirements. Please contact our sales team for further information.
MCP1-COL
Rev. No. 2
Electrical Specification Figure .1
MCP1A-X
Connection Details: See Figure .1
Cable Termination: 0.5-2.5mm2
Maximium Voltage: 30VDC
Current Rating (switch only): 2 Amps

Environmental Specification

Humidity: 0-95% non-condensing


Operating Temperature: -300C to +550C
Storage Temperature: -300C to +550C
Ingress Protection (IP) Rating: IP24D

Mechanical Specification 89mm 27.5mm 32mm


72mm
60mm
Material: PC/ABS
Weight: 110g Flush
160g Surface
93mm

Colour: Green,

72mm
White,
Yellow,
Blue.

Ordering Information
Model Electrical Configuration Colour Mounting Operating Markings
Element
Non Stock
MCP1A-G470SG-11 470Ω Resistor & N\O 30VDC Green Surface Glass PLAIN
MCP1A-Y470SG-11 470Ω Resistor & N\O 30VDC Yellow Surface Glass PLAIN
MCP1A-W470SG-11 470Ω Resistor & N\O 30VDC White Surface Glass PLAIN
MCP1A-B470SG-11 470Ω Resistor & N\O 30VDC Blue Surface Glass PLAIN
MCP1A-G470SF-11 470Ω Resistor & N\O 30VDC Green Surface Flexible PLAIN
MCP1A-Y470SF-11 470Ω Resistor & N\O 30VDC Yellow Surface Flexible PLAIN
MCP1A-W470SF-11 470Ω Resistor & N\O 30VDC White Surface Flexible PLAIN
MCP1A-B470SF-11 470Ω Resistor & N\O 30VDC Blue Surface Flexible PLAIN

N\O= Normally Open Contact

Accessories
Code Description
SC070 Pack Of Ten Test Keys
KG1 x 5 Pack Of Five Glass Elements
PS210 Flexible Operating Element
PS200 Plain Hinged Cover
SC071 Pack Of Ten Terminal Blocks

> KAC Alarm Company Limited


15 - 19 Trescott Road,
Smallwood, Redditch,
Worcestershire B98 7AH.
England.
Telephone: +44 (0) 1527 406655
Fax: +44 (0) 1527 406677
e-mail: [email protected]
Conventional Audible Visual Devices
Sounders
> Product Overview
KAC’s conventional ENscape sounder is a high quality device designed to alert building occupants of an emergency.
The product features a new folded horn design which provides outstanding sound output at low current draw.
With its modern design, global tone set and extensive installer-friendly features, the ENscape sounder is the
logical choice for specifiers, OEMs, installers and distributors.

> ENscape Sounder Benefits

Simple, Fast, Flexible Installation Outstanding Performance

• Modern design eliminates need for device orientation. • Approved to EN54-3.


• First fix capability allowing electrical continuity testing • Superior sound output and low current consumption.
prior to device fitting. • 32 tones all approved to EN54-3.
• Deep base option with multiple cable entries for flexible • Adjustable volume settings.
installation. • Two stage sounders enable alert and alarm sequences
• Designed with full range of common fixing centres. to be set for phased evacuation.
• Positive fit engagement & feedback of base with device • Synchronised sound output.
for easy installation.

Universal Device Quality & Reliability

• Suitable for wall and ceiling mount applications. • Independently approved to all required standards:
• Global tone set: 32 tones including a new bell tone. - Manufacturing: Construction Products Regulation (CPR).
• Range of installation and base options, for indoor and - Product performance: Approved to EN54-3
applications up to IP65. - Environmental: RoHS, WEEE
• Optimised for 12V and 24V systems, making the range • Product range supports system approval.
suitable for use in fire & security applications.

> Introducing the Range


Environmental
Device Approvals Body Colour Installation Options Base Options
Compliance
Standard First Low Profile or
ENscape Sounders EN54-3 Red White RoHS/ WEEE
device Fix Deep/IP65

CAV-S
Rev. No.2
Sounders – Technical Specification
Environmental Specification
Electrical Specification
Operating Temperature: -25°C to 70°C
Operating Voltage: 9 to 29VDC Relative Humidity: 93% ±3%, non condensing
(Approved to EN54-3 @ 9-14V and 18-29V) Ingress Protection: IP21C - low profile base
Average current consumption: 31mA @ 29VDC (Tone 8) IP65 – deep base
Maximum Sound Output: 107dB (A) @ 1m (Tone 23) For RoHS & WEEE Please visit www.kac.co.uk

Mechanical Specification
Dimensions
Body colour: Red / White
Number of Tones: 32 includes a bell tone.
Full tone table available on website or on installation manual
Volume setting: High or medium
Cable Terminal Size: 0.5-2.5mm²
Material: Flame retardant PC/ABS
Gross Weight: Standard device:
190g (low profile base),
197g (deep / IP65 base)
Wiring Options
First Fix option:
200g (low profile base),
207g (Deep / IP65)

First Fix Device Standard Device Connections


Out of Box Contents
First Fix Deep / IP 65 Deep / IP 65 &
ENscape Sounder Standard Device
Option Option First Fix Option

Sounder including selected base ü ü ü ü

P pack (includes terminal block & continuity link) û ü û ü

O Ring for IP65 Sealing û û ü ü

INSTALLATION INSTRUCTIONS FOR CONVENTIONAL WALL & CEILING MOUNT SOUNDER BEACON
MODELS INSTALLATION DIMENSIONS
CWSS-xx-S3 = Sounder Beacon, Shallow Base, O Class STEP 1 Shallow and Deep Base
CWSS-xx-S4 = Sounder Beacon, Shallow Base, O Class, First Fix
CWSS-xx-S5 = Sounder Beacon, Shallow Base, W Class, C Class
100mm

CWSS-xx-S6 = Sounder Beacon, Shallow Base, W Class, First Fix, C Class


CWSS-xx-W3 = Sounder Beacon, Deep Base, O Class
CWSS-xx-W4 = Sounder Beacon, Deep Base, O Class, First Fix
CWSS-xx-W5 = Sounder Beacon, Deep Base, W Class, C Class
122mm

CWSS-xx-W6 = Sounder Beacon, Deep Base, W Class, First Fix, C Class


98mm

xx Denotes Body & Lens Colour

Installation data sheet


TECHNICAL INFORMATION STEP 2 1 - First stage wiring
2 - Second stage wiring
INSTALLATION TIPS

ü ü ü ü
VOLTAGE RANGE (OPERATING) C/W Class 12-29 V
VOLTAGE RANGE (EN54- 23) C/W Class approved at 12-29 V These products are universal devices suitable for wall &
MAX CURRENT CONSUMPTION C/W Class 101mA ceiling mount installations.
MAX POWER CONSUMPTION C/W Class 2.9 W These products are not designed for use with pulsed panel
VOLTAGE RANGE (OPERATING) O Class 12-29 V outputs. If more than 1 mode is required use the second
stage tone.
VOLTAGE RANGE (EN54-23) O Class approved at 24-29 V
+
_ +
_ Continuity link board.
Drill out the required mounting and wiring holes in the rear
VOLTAGE RANGE (EN54-3) 9-14V 18-29V
_ _ First-fix option. of the base. Do not attempt to “knock-out” the holes with a
MAX CURRENT CONSUMPTION O Class 51mA
STEP 3 screwdriver.
MAX POWER CONSUMPTION O Class 1.5 W
No. OF STAGES 2 Factory setting is Tone 1 at medium volume.
BEACON FLASH RATE 0.5Hz Installation tools required: Pliers, Screwdriver, Drill.
MONITORING Reverse polarity
RELATIVE HUMIDITY Up to 93% (± 3%) - non condensing Accessories: -
SC076 = 5x Earth Strap, SC077 = 5x Terminal Block,
WIRE GAUGE FOR TERMINAL 0.5mm2 - 2.5mm2 (max) SC078 = 5x Installer Link, P310 = 5x Deep Base O-Ring,
OPERATING TEMPERATURE -25 to +70oC P311 = 5x Deep Base Gasket, CSR = 5x Shallow Base-
Red, CSW = 5x Shallow Base-White, CWW=5x IP65 Deep
Base-White, CWR = 5x IP65 Deep Base-Red.
VOLUME SETTINGS
See Tone Table
Volume setting is adjusted by switch 6 on the 6-way DIP switch on the on reverse. WARNING: Use extreme caution when adjusting the
bottom of the product. (See switch diagram overleaf). switches on the 6-way DIP switch. The switch contacts
STEP 4 and exposed PCB can be affected by electro-static
TONE SETTINGS
The tone setting is selected by switches 1 to 5 on the 6-way DIP switch. The “click” discharge.
switch diagram and tone table are overleaf. The second stage tone is related WARNING: Care must be taken when installing first-fix
to the first stage tone selection made via the DIP switch. The second stage is model types with the KAC continuity link board. DO NOT
controlled by the fire panel and becomes active through the wiring configuration. touch the exposed link board contacts as this may result in
an electrical shock.
2
BASES/IP RATING The sounder minimum voltage is limited to 12V to maintain
beacon performance.
Shallow Base (IP21C) Deep Base (IP65)
WALL & CEILING MOUNT
1 SOUNDER BEACON MODELS:
CWSS-xx-S3, CWSS-xx-S4
STEP 5
CWSS-xx-S5, CWSS-xx-S6
CWSS-xx-W3
CWSS-xx-W4
CWSS-xx-W5
If the Deep Base IP65 option is used, the o-ring seal must be fitted to the base CWSS-xx-W6
as shown. If required, the deep base gasket accessory can be installed See installation step 3 for
between the base and the mounting surface. anti-tamper screw location. D 1101 Issue C

Accessories:
Low Profile Bases Deep Bases IP and Earthing Kits Electrical Items
CSR – Red low profile base, pack of 5 CWR – Red deep / IP 65, pack of 5 PS 189 – Deep base gasket, pack of 5 SCO77- Terminal block, pack of 5
CSW – White low profile base, pack of 5 CWW – White deep / IP 65 base, pack of 5 PS 188 - Deep base O Ring, pack of 5 SCO78- Installer link, pack of 5
SC076 - Earth strap, pack of 5

Order Information:
Code Body Colour Base Option Install Option Example Part No.

RR=Red S=Low Profile 1=Standard Device CWSO-RR-S1


CWSO
WW=White W=IP65/Deep 2=First Fix CWSO-WW-W2

> KAC Alarm Company Ltd KAC House, Thornhill Road, North Moons Moat, Redditch, B98 9ND, United Kingdom
Tel: +44 (0) 1527 406655 Fax: +44 (0) 1527 406677 e-mail: [email protected]

We reserve the right to amend the content of this document without prior notice.
Warning Signage: EV & GD
Specifications
DESCRIPTION : “EVACUATE AREA IMMEDIATELY” Signage

MODEL : EV-LED
CURRENT
: 200mA
CONSUMPTION
OPERATING
: 24V DC
VOLTAGE
LAMP TYPE : LED

FUNCTION : Steady / Flashing


MATERIAL / : Electrode Galvanized Steel Sheet with Epoxy
COLOR Powder Coating – White / Red Color
DIMENSION : 375mm(L) x 80mm(W) x 165mm(H)
Model: EV-LED
WEIGHT : 1.3Kg
OPERATING
: 15ºC - 60ºC
TEMPERATURE

DESCRIPTION : “GAS DISCHARGED” Signage

MODEL : GD-LED
CURRENT
: 200mA
CONSUMPTION
OPERATING
: 24V DC
VOLTAGE
LAMP TYPE : LED

FUNCTION : Steady / Flashing


MATERIAL / : Electrode Galvanized Steel Sheet with Epoxy
COLOR Powder Coating – White / Red Color
DIMENSION : 375mm(L) x 80mm(W) x 165mm(H)

WEIGHT : 1.3Kg
Model: GD-LED
OPERATING
: 15ºC - 60ºC
TEMPERATURE

Acclaim Systems Pte Ltd


171 Kaki Bukit Avenue
Shun Li Industrial Park EVACUATE
Singapore 416020 AREA
IMMEDIATELY
Selectable Output
Horns, Strobes, and
Horn Strobes

System Sensor selectable output horns, strobes, and

horn strobes are rich with features guaranteed to


reduce installation times and maximize profits.

Features The System Sensor line of notification devices offers the most
• Mounting plate included for compatibility with a wide range of flexibile and easy-to-use line of horns, strobes, and horn strobes in
back box sizes the industry. With white and red housing, universal fire symbol and
a ceiling mount accessory available these devices can meet virtually
• Three field selectable candela settings: 15, 75, and 115
any application. They also mount to a wide variety of back box sizes
• Easy to use rotary dials for selection of candela and horn settings to offer the most flexibility in installation.
• Built in synchronization feature keeps strobes in sync for
up to 30 minutes This line of devices features a wide variety of features that
• Strobes Listed to UL 1638; Horns Listed to UL 464 simplifies installations. The mounting plate allows the devices to
be compatible with a wide range of back box sizes. Settings for the
• Horn settings on the horn strobe model include high and low
strobe and horn are done using easy to set rotary switches on the
volume, continuous or temporal 3 tone
back of the device. Synchronization is achieved without the use of
• Round trim ring available for ceiling mount applications additional modules; when powered with a filtered DC source, the
• Universal Fire symbol is language independent strobe portion is capable of self synchronization for 30 minutes per
• Trim plate allows mini horn to mount to a variety of back boxes NFPA 72.
and fit aesthetically with the horn strobe and strobe
Three candela options are available for the strobe when it works on
24 volts or full wave rectified power. Only 15 candela is available
for strobe when it works on 12 volts. On the horn strobe model, high
and low volume are options for the horn as well as a continuous tone
or temporal 3 output. The mini horn model has a continuous tone
output and one volume setting.

Available accessories include a round trim ring to adapt the wall


Agency Listings device for ceiling mount applications. Simply install the round ring
over the square device for a perfect fit on the ceiling. An adapter
plate is also available for the mini horn. It fits to a wider range of
back boxes and fits with the family look of the horn strobe and
strobe devices.
System Sensor Specifications
Architect/Engineer Specifications
General
System Sensor strobe and horn strobes shall mount to a 2“x4”, 4“x4”, single-gang, double-gang, 4“ Octagon, 105mm x 105mm, 65mm round, 86mm x 86
mm, 60mm x 60mm back box. System Sensor devices shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal
12/24 volts. 12-volt-rated notification appliance circuit outputs shall operate between 8 and 17.5 volts. 24-volt-rated notification appliance circuit outputs
shall operate between 17 and 33 volts. Devices operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power
supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 75 and 115 cd. When devices work on 12 volts, only 15 candela is
available. The devices shall not operate on a coded power supply. Horn - strobe and strobe devices shall have built-in synchronization capability. Upon initial
power up the devices shall be synchronized for up to 30 minutes.

Strobe
The strobe shall be a System Sensor Model _______ listed to UL 1638 and shall be approved for fire protective service. The strobe shall be wired as a
primary-signaling notification appliance flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube
and associated lens/reflector system.

Horn Strobe Combination


The horn strobe shall be a System Sensor Model _______ listed to UL 1638 and UL 464 and shall be approved for fire protective service. The horn strobe
shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling
appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector
system. The horn shall have two audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These
options are set by a multiple position switch.

Mini Horn
The mini horn shall mount to a single-gang back box. With the accessory trim plate it shall mount to a 2" × 4", 4" × 4", single-gang, double-gang, 105mm
× 150mm, 65mm round, 86mm × 86mm, 60mm × 60mm back box. The mini horn shall provide a continuous tone output.
Physical/Electrical Specifications
Standard Operating Temperature 32℉ to 120 ℉ (0℃ to 49℃)
Humidity Range 10 to 93% non-condensing
Strobe Flash Rate 1 flash per second
Nominal Voltage Regulated 24 DC/FWR1 or regulated 12 DC/FWR#
Operating Voltage Range 16 to 33 V (24 V nominal); 8 to 17.5 V (12 V nominal)
Input Terminal Wire Gauge 14 to 18 AWG*
Strobe And Horn Strobes Dimensions(including lens) 5.15" L × 5.0" W × 1.5" D (131 mm L× 127mm W × 38mm D)
Ceiling Trim ring Dimensions (sold as a pack of 5) 6.8 " dia / 1.5" depth (173 mm dia / 38mm depth)
Mini Horn Dimensions 4.6"L × 2.9" W × 0.45" D (117 mm L× 74 mm W× 11.5mm D)
Mini Horn Trim Plate (sold as a pack of 5) 5.1" L × 5.0" W × 1.73" D (131 mm L × 127 mm W × 43 mm D)
# Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs.

* Mini horn is rated for 12 to 18 AWG


UL Current Draw Data
HORN/STROBE CURRENT DRAW(mA) STROBE CURRENT DRAW(mA)
16–33 Volts 8-17.5 Volts Switch 16–33 Volts 8–17.5 Volts
DC Input Candela
15 cd 75 cd 115 cd 15 cd Position DC FWR DC FWR
Temporal High 48 80 98 63 Standard Position 1 15 37 45 58 58
Temporal Low 43 75 95 63 Candela Position 2 75 71 71 N/A N/A
Continuous High 48 80 98 65 Range Position 3 115 89 92 N/A N/A
Continuous Low 43 75 95 63
FWR Input
Temporal High 55 89 108 62
Temporal Low 50 84 103 62
Continuous High 55 89 108 65
Continuous Low 50 84 103 63

Horn Tones and Sound Output Data


HORN OUTPUT (dBA) IN UL REVERBERANT ROOM
24 V Nominal Measurements 12V Nominal Measurements
Switch Sound 16–33 Volts † 8-17.5 Volts †
Volume Reverberant Anechoic Reverberant Anechoic
Postition Pattern
DC FWR DC FWR DC FWR DC FWR DC FWR DC FWR
1 Temporal High 78 77 78 77 103 104 72* 71* 76 73* 88 85
2 Temporal Low 74* 73* 74* 73* 100 101 70* 69* 72* 70* 86 83
3 Continuous High 82 80 82 80 103 104 76 75 80 77 87 85
4 Continuous Low 80 78 80 78 100 101 74* 72* 77 75 86 82
† Minimum dB rating for Operational Voltage Range as per UL 464.
*For Private Mode use only.

Mini Horn Sound Output Data (dBA) Mini Horn Current Draw (mA)
Tone Power Supply 12V 24V Tone Power Supply 12V 24V
DC 75 82 DC 13 21
Continuous Continuous
FWR 75 80 FWR 13 22

Candela Settings
Rotary Switch Candela Output - Candela Output -
Position Clear lens Red lens
1 15 3
2 75 16
3 115 25
4.960 in. (126mm)

5.15 in. (131 mm)

Wall Mount Horn Strobe Product Wall Mount Horn Strobe with Optional Ceiling Trim Ring
5.0 in. (127mm ) 1.73 in.
0.45 in. (43mm)
2.90 in. (74mm) (11.5mm)

5.1 in.
4.600 in. (131mm)
(117mm)

Mini Horn Mini Horn with Optional Trim Plate


System Sensor Ordering Information
Model Type Housing Color Lens Color Lettering House on Fire Symbol
Horn Strobe Horn Strobe Trim Plate Red White Red Clear Chinese English
SYS-HS √ √ √ √
SYS-HS-FIRE* √ √ √ √ √
SYS-HSR √ √ √ √ √
SYS-HSR-FIRE √ √ √ √ √
SYS-HSW √ √ √ √
SYS-HSRW √ √ √ √ √
SYS-HSRW-FIRE √ √ √ √ √
SYS-ST √ √ √ √
SYS-ST-FIRE* √ √ √ √ √
SYS-STR √ √ √ √ √
SYS-STR-FIRE √ √ √ √ √
SYS-STW √ √ √ √
SYS-STW-FIRE* √ √ √ √ √
SYS-STRW √ √ √ √ √
SYS-STRW-FIRE √ √ √ √ √
SYS-CTP √ √ √
SYS-CTPR √ √ √ √
SYS-CTPR-FIRE √ √ √ √
SYS-CTPW √ √ √
SYS-CTPRW √ √ √ √
SYS-CTPRW-FIRE √ √ √ √
MHR1 √ √
SYS-MHTP √ √
*The marked models are only ordering model number. The model number on the product label, UL approval and instruction manual remains without “-FIRE”

Product specifications subject to change without notice. Visit systemsensor.com for


28 Tuan Jie South Road, Xi’an National • Province of Shaanxi, 710075, China current product information, including the latest version of this data sheet.
Phone: (029) 85387800 • Fax: (029) 88895930 Copyright by Xi‘an System Sensor Electronics LTD.
S2-1315-001_D