0% found this document useful (0 votes)
39 views56 pages

conga-TEVAL/COMe 3.0 User's Guide

The document is a user guide for the congatec COM Express™ Type 6 revision 3.0 evaluation carrier board, detailing its components, features, and connectors. It includes revision history, disclaimers, intended audience, and technical support information, along with specifications and connector layouts. The guide is intended for technically qualified personnel and emphasizes compliance with RoHS and electrostatic safety measures.

Uploaded by

chooze
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views56 pages

conga-TEVAL/COMe 3.0 User's Guide

The document is a user guide for the congatec COM Express™ Type 6 revision 3.0 evaluation carrier board, detailing its components, features, and connectors. It includes revision history, disclaimers, intended audience, and technical support information, along with specifications and connector layouts. The guide is intended for technically qualified personnel and emphasizes compliance with RoHS and electrostatic safety measures.

Uploaded by

chooze
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 56

conga-TEVAL/COMe 3.

0
Detailed description of the congatec COM Express™ Type 6 revision 3.0 evaluation carrier board

User’s Guide

Revision 1.1
Copyright © 2018 congatec AG TEVA2m11 1/56
Revision History
Revision Date (yyyy-mm-dd) Author Changes
1.0 2018-08-16 AEM •• Official release
1.1 2019-09-23 AEM •• Updated the title page image
•• Added section 1.3 “Order Number”
•• Corrected the storage temperature in section 4.3 “Environmental Specifications”
•• Changed conga-TEVAL2 to conga-TEVAL/COMe 3.0
•• Corrected LED D68 color description in table 9 “Power LEDs Status”
•• Changed the warning icons in sections 4.9.1 “Disk Drive Power Connector” and 4.15 “LPC/eSPI” to caution icon

Copyright © 2018 congatec AG TEVA2m11 2/56


Preface
This user’s guide provides information about the components, features and connectors available on the congatec COM Express™ Type 6,
revision 3.0 evaluation carrier board.

Disclaimer
The information contained within this user’s guide, including but not limited to any product specification, is subject to change without notice.

congatec AG provides no warranty with regard to this user’s guide or any other information contained herein and hereby expressly disclaims
any implied warranties of merchantability or fitness for any particular purpose with regard to any of the foregoing. congatec AG assumes
no liability for any damages incurred directly or indirectly from any technical or typographical errors or omissions contained herein or for
discrepancies between the product and the user’s guide. In no event shall congatec AG be liable for any incidental, consequential, special, or
exemplary damages, whether based on tort, contract or otherwise, arising out of or in connection with this user’s guide or any other information
contained herein or the use thereof.

Intended Audience
This user’s guide is intended for technically qualified personnel. It is not intended for general audiences.

Lead-Free Designs (RoHS)


All congatec AG designs are created from lead‑free components and are completely RoHS compliant.

Electrostatic Sensitive Device


All congatec AG products are electrostatic sensitive devices. They are enclosed in static shielding bags, and shipped enclosed in secondary
packaging (protective packaging). The secondary packaging does not provide electrostatic protection.

Do not remove the device from the static shielding bag or handle it, except at an electrostatic-free workstation. Also, do not ship or store
electronic devices near strong electrostatic, electromagnetic, magnetic, or radioactive fields unless the device is contained within its original
packaging. Be aware that failure to comply with these guidelines will void the congatec AG Limited Warranty

Copyright © 2018 congatec AG TEVA2m11 3/56


Symbols
The following symbols are used in this user’s guide:

Warning

Warnings indicate conditions that, if not observed, can cause personal injury.

Caution

Cautions warn the user about how to prevent damage to hardware or loss of data.
Note

Notes call attention to important information that should be observed.


Connector Type

Describes the connector that must be used with the congatec COM Express™ evaluation carrier board, not the connector found on the
congatec COM Express™ evaluation carrier board.

Link to connector layout diagram

This link icon is located in the top left corner of each page. It provides a direct link to the connector layout diagram on page 8 of this document.

Copyright Notice
Copyright © 2018, congatec AG. All rights reserved. All text, pictures and graphics are protected by copyrights. No copying is permitted
without written permission from congatec AG.

congatec AG has made every attempt to ensure that the information in this document is accurate yet the information contained within is
supplied “as-is”.

Copyright © 2018 congatec AG TEVA2m11 4/56


Trademarks
Product names, logos, brands, and other trademarks featured or referred to within this user’s guide, or the congatec website, are the property
of their respective trademark holders. These trademark holders are not affiliated with congatec AG, our products, or our website.

Warranty
congatec AG makes no representation, warranty or guaranty, express or implied regarding the products except its standard form of limited
warranty (“Limited Warranty”) per the terms and conditions of the congatec entity, which the product is delivered from. These terms and
conditions can be downloaded from www.congatec.com. congatec AG may in its sole discretion modify its Limited Warranty at any time and
from time to time.

The products may include software. Use of the software is subject to the terms and conditions set out in the respective owner’s license
agreements, which are available at www.congatec.com and/or upon request.

Beginning on the date of shipment to its direct customer and continuing for the published warranty period, congatec AG represents that the
products are new and warrants that each product failing to function properly under normal use, due to a defect in materials or workmanship or
due to non conformance to the agreed upon specifications, will be repaired or exchanged, at congatec’s option and expense.

Customer will obtain a Return Material Authorization (“RMA”) number from congatec AG prior to returning the non conforming product freight
prepaid. congatec AG will pay for transporting the repaired or exchanged product to the customer.

Repaired, replaced or exchanged product will be warranted for the repair warranty period in effect as of the date the repaired, exchanged
or replaced product is shipped by congatec, or the remainder of the original warranty, whichever is longer. This Limited Warranty extends to
congatec’s direct customer only and is not assignable or transferable.

Except as set forth in writing in the Limited Warranty, congatec makes no performance representations, warranties, or guarantees, either
express or implied, oral or written, with respect to the products, including without limitation any implied warranty (a) of merchantability, (b) of
fitness for a particular purpose, or (c) arising from course of performance, course of dealing, or usage of trade.

congatec AG shall in no event be liable to the end user for collateral or consequential damages of any kind. congatec shall not otherwise be
liable for loss, damage or expense directly or indirectly arising from the use of the product or from any other cause. The sole and exclusive
remedy against congatec, whether a claim sound in contract, warranty, tort or any other legal theory, shall be repair or replacement of the
product only.

Certification ISO 9001

C N
ER
T I F I C AT I O TM

congatec AG is certified to DIN EN ISO 9001 standard.

Copyright © 2018 congatec AG TEVA2m11 5/56


Technical Support
congatec AG technicians and engineers are committed to providing the best possible technical support for our customers so that our products
can be easily used and implemented. We request that you first visit our website at www.congatec.com for the latest documentation, utilities
and drivers, which have been made available to assist you. If you still require assistance after visiting our website then contact our technical
support department by email at [email protected]

Terminology

Term Description
PCIe Peripheral Component Interface Express (PCI Express)
SDIO Secure Digital Input Output
USB Universal Serial Bus
SATA Serial AT Attachment. A serial-interface standard for hard disks
HDA High Definition Audio
I²C Bus Inter-Integrated Circuit Bus
SM Bus System Management Bus
GbE Gigabit Ethernet
LVDS Low Voltage Differential Signaling
HBR3 High Bit Rate 3
DDC Display Data Channel
GPIO General Purpose Input/Output
eDP Embedded DisplayPort
LVDS Low Voltage Differential Signaling
N.C Not connected
N.A Not available
T.B.D To be determined

Copyright © 2018 congatec AG TEVA2m11 6/56


Contents
1 Introduction.............................................................................. 10 4.7.3.2 LVDS ......................................................................................... 31
4.7.3.3 LVDS Panel and Backlight Power Supply.................................. 32
1.1 COM Express™ Concept.......................................................... 10
4.7.3.4 Flat Panel and Backlight Voltage Selection.............................. 32
1.2 conga-TEVAL/COMe 3.0 ......................................................... 10
4.7.3.5 Flat Panel and Backlight Power Supply Connection................. 33
1.3 Order Number.......................................................................... 11
4.7.3.6 Flat Panel Configuration Data................................................... 34
2 Connector Layout..................................................................... 12 4.8 Universal Serial Bus (USB)......................................................... 34
4.8.1 Dual Stacked USB 3.1 Type-A .................................................. 35
3 Specifications............................................................................ 13 4.8.2 USB Type-B (Client Mode)........................................................ 36
3.1 Feature List............................................................................... 13 4.8.3 Dual Stacked USB 2.0 Type-A................................................... 36
3.2 Mechanical Dimensions............................................................ 14 4.9 SATA/SATADOM....................................................................... 37
3.3 Environmental Specifications.................................................... 14 4.9.1 Disk Drive Power Connector..................................................... 37
4.9.2 SATA Power.............................................................................. 38
4 Connectors and Features.......................................................... 15
4.10 Gigabit Ethernet (GbE)............................................................. 38
4.1 COM Express A - B Connector................................................. 15 4.11 Audio Interfaces........................................................................ 39
4.2 COM Express C - D Connector................................................. 17 4.11.1 MIC-In....................................................................................... 40
4.3 Power Supply Connector.......................................................... 18 4.11.2 Line-Out.................................................................................... 40
4.3.1 ATX Power Connector.............................................................. 19 4.11.3 Optical S/PDIF-Out................................................................... 40
4.3.2 DC Banana Jack........................................................................ 20 4.11.4 HDA Adapter/Debug Header................................................... 41
4.3.3 Status LEDs D68-D72, D84-D86............................................... 21 4.12 SM Bus...................................................................................... 41
4.3.4 PWR_OK Signal......................................................................... 21 4.13 I2C Bus....................................................................................... 42
4.3.5 Power-Up Control..................................................................... 22 4.14 SPI Bus...................................................................................... 42
4.3.6 Power Consumption Header.................................................... 22 4.15 LPC/eSPI................................................................................... 43
4.3.7 Module Type Detection............................................................ 22 4.16 LPC/TPM Header...................................................................... 44
4.4 CMOS Battery Holder .............................................................. 23 4.17 Serial Ports (COM Ports)........................................................... 45
4.5 PCIe Connectors....................................................................... 24 4.17.1 COM Port 0 Header.................................................................. 45
4.5.1 PEG x16 Slot............................................................................. 25 4.17.2 COM Port 1 Header.................................................................. 46
4.5.2 PCIe x4 Slot.............................................................................. 25 4.17.3 Module Serial Port 0................................................................. 46
4.5.3 PCIe x1 Slot.............................................................................. 26 4.17.4 Module Serial Port 1/CAN Bus................................................. 47
4.5.4 Mini PCIe Socket....................................................................... 26 4.18 System Fan Header................................................................... 47
4.5.5 M.2............................................................................................ 27 4.19 CPU Fan Header....................................................................... 49
4.6 SD Card Slot............................................................................. 28 4.20 Smart Battery Management Header......................................... 49
4.7 Display Interfaces...................................................................... 29 4.21 Debug Pin Header.................................................................... 50
4.7.1 VGA.......................................................................................... 29 4.22 Internal Use Only...................................................................... 50
4.7.2 DP++........................................................................................ 29 4.23 Feature Connector.................................................................... 51
4.7.3 LVDS/eDP.................................................................................. 29
5 Additional Features................................................................... 52
4.7.3.1 eDP........................................................................................... 30

Copyright © 2018 congatec AG TEVA2m11 7/56


5.1 Buttons...................................................................................... 52
5.1.1 Power........................................................................................ 52
5.1.2 Reset......................................................................................... 52
5.1.3 LID............................................................................................. 52
5.1.4 Sleep......................................................................................... 53
5.2 Beeper...................................................................................... 53
5.3 Ground Test Points.................................................................... 53
5.4 Debug Display.......................................................................... 54
6 Mechanical Dimensions............................................................ 55

7 Industry Specifications.............................................................. 56

Copyright © 2018 congatec AG TEVA2m11 8/56


List of Tables
Table 1 Order Description..................................................................... 11 Table 35 X33 - Ethernet SDP .................................................................. 39
Table 2 Feature Summary...................................................................... 13 Table 36 MIC-In (X47) Pinout Description.............................................. 40
Table 3 Module Type 6 Connector Pinout—Rows A and B................... 15 Table 37 Line-Out (X47) Pinout Description............................................ 40
Table 4 Module Type 6 Connector Pinout—Rows C and D................... 17 Table 38 SW9.2 - HDA Codec Configuration.......................................... 41
Table 5 X63 - ATX Power....................................................................... 19 Table 39 X49 - HDA Adapter Pinout Description.................................... 41
Table 6 SW21.1 - ATX PSU Control Description.................................... 19 Table 40 SW14 - BIOS Boot Device Selection......................................... 42
Table 7 JP11 - ATX 5V Standby Connection......................................... 20 Table 41 SW10.1 - Super I/O Control...................................................... 43
Table 8 X41/X42 - DC Banana Jack....................................................... 20 Table 42 SW10.2 - LPC/eSPI Mode Control............................................ 43
Table 9 SW21.2 - 12 V Voltage Regulator Control (Only via DC Banana Table 43 SW11 - Super IO Configuration................................................ 44
Jack).......................................................................................... 20 Table 44 X51 - LPC/TPM Pinout Description........................................... 44
Table 10 Power LEDs Status.................................................................... 21 Table 45 X53 - COM 0 Pinout Description.............................................. 45
Table 11 JP9 - Module PWR_OK Selection............................................. 21 Table 46 SW12 - COM Port 0 Transceiver Configuration........................ 45
Table 12 X3/X4 - Power Consumption Measurement............................. 22 Table 47 SW13 - COM Port 0 Slew Rate/Termination............................. 46
Table 13 Module Type Detection Pinout Description.............................. 22 Table 48 X52 - COM 1 Pinout Description.............................................. 46
Table 14 JP8 - RTC Battery Connection ................................................. 23 Table 49 SW2.2 - SER1/CAN Selection................................................... 47
Table 15 SW1 - PCIe x4 Slot Configuration............................................. 25 Table 50 JP7 - CAN Bus Termination/Filter ............................................ 47
Table 16 PCIe x1 Lane Routing............................................................... 26 Table 51 X55 - SYS Fan Pinout ............................................................... 48
Table 17 D6-D8 - mini PCIe LEDs Description........................................ 26 Table 52 JP5 - Fan Voltage Selection...................................................... 48
Table 18 SW2.1 - PCIe Lane 5 Configuration.......................................... 27 Table 53 JP6 - Fan Speed Control........................................................... 48
Table 19 SW3 - M.2 Configuration.......................................................... 27 Table 54 X60 - CPU Fan........................................................................... 49
Table 20 SW4 - M.2/mini PCIe Configuration......................................... 27 Table 55 JP10 - CPU Fan Voltage Selection............................................ 49
Table 21 SW 5.2 - GPIO/SDIO Connection............................................. 28 Table 56 X61 - SBM Pinout...................................................................... 49
Table 22 SW8.1 - eDP/LVDS Selection.................................................... 29 Table 57 X57 - Debug Pin Header........................................................... 50
Table 23 X39 - eDP Pinout Description................................................... 30 Table 58 X56 - Feature Connector Pinout Description........................... 51
Table 24 X38 - LVDS Pinout Description.................................................. 31 Table 59 SW9.1 - Beeper Control............................................................ 53
Table 25 X40 - LVDS Power Pinout Description....................................... 32 Table 60 SW22 - POST Code Decoder................................................... 54
Table 26 JP3 - Flat Panel Voltage Selection............................................ 32 Table 61 SW22 - POST Code LPC/I2C Address Decoder....................... 54
Table 27 JP4 - Backlight Voltage Selection............................................. 32 Table 62 References................................................................................ 56
Table 28 SW8.2 - Backlight Enable Signal Configuration........................ 33
Table 29 SW5.1 - USB Port 0 Configuration............................................ 35
Table 30 JP1 - SATA/SATADOM Configuration ...................................... 37
Table 31 X26 - External SATA Activity LED.............................................. 37
Table 32 X24 - SATA Power Pinout Description...................................... 38
Table 33 GbE (X32) Status LEDs.............................................................. 38
Table 34 JP2 - Ethernet LEDs Power Configuration................................ 38

Copyright © 2018 congatec AG TEVA2m11 9/56


1 Introduction
1.1 COM Express™ Concept
COM Express™ is an open industry standard defined specifically for COMs (computer on modules). Its creation makes it possible to smoothly
transition from legacy interfaces to the newest technologies available today.

A Computer On Module integrates all the core components and standard I/O interfaces of a common PC onto an application specific carrier
board. The key advantage of the COM in the embedded computer industries is that all the highly integrated, high speed components such as
CPU, chipsets and memory are combined on a small module form factor for easy adaptation into different applications across multiple market
segments.

COM Express™ modules have standardized form factors and specified pinouts on the two system connectors that remain the same regardless
of the vendor. The COM Express™ module reflects the functional requirements for a wide range of embedded applications. These functions
include, but are not limited to, PCI Express, PCI, Graphics, High Definition Audio, parallel ATA, serial ATA, Gigabit Ethernet and USB ports.
Two ruggedized, shielded connectors provide the carrier board interface and carry all the I/O signals to and from the COM Express™ module.

Carrier board designers can use as little or as many of the I/O interfaces as deemed necessary. The carrier board can therefore provide all
the interface connectors required to attach the system to the application specific peripherals. This versatility allows the designer to create a
dense and optimized package, which results in a more reliable product while simplifying system integration. Most importantly, COM Express™
modules are scalable, which means once an application has been created there is the ability to diversify the product range through the use
of different performance class or form factor size modules. Simply unplug one module and replace it with another; no redesign is necessary.

1.2 conga-TEVAL/COMe 3.0


The conga-TEVAL/COMe 3.0 carrier board is designed based on the Type 6 pinout definition and it complies with COM Express Specification
3.0. The conga-TEVAL/COMe 3.0 provides most of the functional requirements for any embedded PC application. These functions include, but
are not limited to a rich complement of contemporary high bandwidth serial interfaces such as PCI Express, Serial ATA, USB 2.0, and Gigabit
Ethernet. To ensure stable data throughput, the carrier board is equipped with two high performance connectors in accordance with the COM
Express specification.

By combining the scalability of COM Express modules, the conga-TEVAL/COMe 3.0 carrier board provides manufacturers and developers
with a platform to jump-start the development of systems and applications based on COM Express specification. This helps to reduce product
design cycle and encourages rapid innovation in system design, to meet the ever-changing needs of the market.

The various features and capabilities offered by the conga-TEVAL/COMe 3.0 makes it ideal for the integration of Compact and Basic form
factor CPU modules.

Copyright © 2018 congatec AG TEVA2m11 10/56


1.3 Order Number
Table 1 Order Description

Part Number Product Name Description


065810 conga-TEVAL2 (conga-TEVAL/COMe 3.0) Evaluation carrier board for COM Express Type 6 rev 3.0 modules

Copyright © 2018 congatec AG TEVA2m11 11/56


2 Connector Layout
The connector layout
picture below shows
each connector and its
name designator. Select
the Adobe ‘Zoom-In-
Tool’ and zoom in on a
given component to see
its designator. Hover
over the component and
the ‘Zoom-In-Tool’ will
change indicating there
is a link. Click on the link
to navigate to the area in
the document where the
component is described.
Use the mouse icon in the
top left hand corner of the
destination page to return
to the connector layout
picture.

Copyright © 2018 congatec AG TEVA2m11 12/56


3 Specifications
3.1 Feature List
Table 2 Feature Summary

Form Factor Based on COM Express standard pinout Type 6, rev. 3.0
Supported Modules COM Express™ Type 6 compact and basic form factor
Power 1 x standard 24-pin ATX connector
1 x DC power input (4 mm banana connectors)
1 x CR2032 CMOS/RTC battery
Back Panel I/O 1 x Gigabit Ethernet RJ45 port 3 x DP++ ports
Connectors 1 x Microphone jack 4 x USB 3.1 host ports
1 x Line-OUT jack 2 x USB 2.0 host ports
1 x Optical S/PDIF-Out port
Onboard I/O 1 x USB client port 4 x SATA connectors (one connector supports SATADOM)
Connectors 1 x PEG x16 slot 1 x SATA power connector
1 x PCIe x4 slot 1 x Disk drive 4-pin connector
5 x PCIe x1 slot 1 x HDA adapter/debug header
1 x VGA port 1 x I2C EEPROM socket
1 x M.2 Key B socket 1 x SPI flash socket
1 x mini PCIe socket 1 x LPC/TPM header
2 x micro-SIM card socket 2 x COM port headers
1 x SD card socket (full-size) 1 x CAN connector
1 x LVDS connector 2 x Fan headers
1 x eDP connector 1 x SBM header
1 x Panel and Backlight header 1 x Feature connector
1 x EPI EEPROM Socket
Optional Onboard 1 x Power consumption header
Interfaces
Other Features 1 x Beeper
4 x Buttons (power, reset, sleep, lid)
4 x Ground test points
Four 14-segment displays for post code information
Multi-channel low power HD audio codec (Cirrus CS4207)
Super I/O (Nuvoton NCT6112D)

Note
The module must also support the features for them to function. Refer to the module’s user’s guide for information about supported features.

Copyright © 2018 congatec AG TEVA2m11 13/56


3.2 Mechanical Dimensions
•• 294.0 mm x 244.0 mm
•• Height approximately 43.0 mm (top side)

3.3 Environmental Specifications


Temperature Operation: -40°C to 85°C Storage: -40°C to +85°C

Humidity Operation: 10% to 90% Storage: 5% to 95%


Note

The above operating temperatures must be strictly adhered to at all times. The maximum operating temperature refers to any measurable
spot on the modules surface.

Humidity specifications are for non-condensing conditions.

Copyright © 2018 congatec AG TEVA2m11 14/56


4 Connectors and Features
4.1 COM Express A - B Connector
Table 3 Module Type 6 Connector Pinout—Rows A and B

Pin Row A Pin Row B Pin Row A Pin Row B


A1 GND (FIXED) B1 GND (FIXED) A56 PCIE_TX4- B56 PCIE_RX4-
A2 GBE0_MDI3- B2 GBE0_ACT# A57 GND B57 GPO2
A3 GBE0_MDI3+ B3 LPC_FRAME#/ESPI_CS0# A58 PCIE_TX3+ B58 PCIE_RX3+
A4 GBE0_LINK100# B4 LPC_AD0/ESPI_IO_0 A59 PCIE_TX3- B59 PCIE_RX3-
A5 GBE0_LINK1000# B5 LPC_AD1/ESPI_IO_1 A60 GND (FIXED) B60 GND (FIXED)
A6 GBE0_MDI2- B6 LPC_AD2/ESPI_IO_2 A61 PCIE_TX2+ B61 PCIE_RX2+
A7 GBE0_MDI2+ B7 LPC_AD3/ESPI_IO_3 A62 PCIE_TX2- B62 PCIE_RX2-
A8 GBE0_LINK# B8 LPC_DRQ0#/ESPI_ALERT0# A63 GPI1 B63 GPO3
A9 GBE0_MDI1- B9 LPC_DRQ1#/ESPI_ALERT1# A64 PCIE_TX1+ B64 PCIE_RX1+
A10 GBE0_MDI1+ B10 LPC_CLK/ESPI_CK A65 PCIE_TX1- B65 PCIE_RX1-
A11 GND (FIXED) B11 GND (FIXED) A66 GND B66 WAKE0#
A12 GBE0_MDI0- B12 PWRBTN# A67 GPI2 B67 WAKE1#
A13 GBE0_MDI0+ B13 SMB_CK A68 PCIE_TX0+ B68 PCIE_RX0+
A14 GBE0_CTREF B14 SMB_DAT A69 PCIE_TX0- B69 PCIE_RX0-
A15 SUS_S3# B15 SMB_ALERT# A70 GND (FIXED) B70 GND (FIXED)
A16 SATA0_TX+ B16 SATA1_TX+ A71 eDP_TX2+/LVDS_A0+ B71 LVDS_B0+
A17 SATA0_TX- B17 SATA1_TX- A72 eDP_TX2-/LVDS_A0- B72 LVDS_B0-
A18 SUS_S4# B18 SUS_STAT#/ESPI_RESET# A73 eDP_TX1+/LVDS_A1+ B73 LVDS_B1+
A19 SATA0_RX+ B19 SATA1_RX+ A74 eDP_TX1-/LVDS_A1- B74 LVDS_B1-
A20 SATA0_RX- B20 SATA1_RX- A75 eDP_TX0+/LVDS_A2+ B75 LVDS_B2+
A21 GND (FIXED) B21 GND (FIXED) A76 eDP_TX0-/LVDS_A2- B76 LVDS_B2-
A22 SATA2_TX+ B22 SATA3_TX+ A77 eDP_VDD_EN/LVDS_VDD_EN B77 LVDS_B3+
A23 SATA2_TX- B23 SATA3_TX- A78 LVDS_A3+ B78 LVDS_B3-
A24 SUS_S5# B24 PWR_OK A79 LVDS_A3- B79 eDP_BKLT_EN/LVDS_BKLT_EN
A25 SATA2_RX+ B25 SATA3_RX+ A80 GND (FIXED) B80 GND (FIXED)
A26 SATA2_RX- B26 SATA3_RX- A81 eDP_TX3+/LVDS_A_CK+ B81 LVDS_B_CK+
A27 BATLOW# B27 WDT A82 eDP_TX3-/LVDS_A_CK- B82 LVDS_B_CK-
A28 (S)ATA_ACT# B28 HDA_SDIN2 A83 eDP_AUX+/LVDS_I2C_CK B83 eDP/LVDS_BKLT_CTRL
A29 HDA_SYNC B29 HDA_SDIN1 A84 eDP_AUX-/LVDS_I2C_DAT B84 VCC_5V_SBY
A30 HDA_RST# B30 HDA_SDIN0 A85 GPI3 B85 VCC_5V_SBY
A31 GND (FIXED) B31 GND (FIXED) A86 RSVD B86 VCC_5V_SBY
A32 HDA_BITCLK B32 SPKR A87 eDP_HPD B87 VCC_5V_SBY

Copyright © 2018 congatec AG TEVA2m11 15/56


Pin Row A Pin Row B Pin Row A Pin Row B
A33 HDA_SDOUT B33 I2C_CK A88 PCIE_CLK_REF+ B88 BIOS_DIS1#
A34 BIOS_DIS0#/ESPI_SAFS B34 I2C_DAT A89 PCIE_CLK_REF- B89 VGA_RED
A35 THRMTRIP# B35 THRM# A90 GND (FIXED) B90 GND (FIXED)
A36 USB6- B36 USB7- A91 SPI_POWER B91 VGA_GRN
A37 USB6+ B37 USB7+ A92 SPI_MISO B92 VGA_BLU
A38 USB_6_7_OC# B38 USB_4_5_OC# A93 GPO0 B93 VGA_HSYNC
A39 USB4- B39 USB5- A94 SPI_CLK B94 VGA_VSYNC
A40 USB4+ B40 USB5+ A95 SPI_MOSI B95 VGA_I2C_CK
A41 GND (FIXED) B41 GND (FIXED) A96 TPM_PP B96 VGA_I2C_DAT
A42 USB2- B42 USB3- A97 TYPE10# B97 SPI_CS#
A43 USB2+ B43 USB3+ A98 SER0_TX B98 RSVD
A44 USB_2_3_OC# B44 USB_0_1_OC# A99 SER0_RX B99 RSVD
A45 USB0- B45 USB1- A100 GND (FIXED) B100 GND (FIXED)
A46 USB0+ B46 USB1+ A101 SER1_TX B101 FAN_PWMOUT
A47 VCC_RTC B47 ESPI_EN# A102 SER1_RX B102 FAN_TACHIN
A48 RSVD B48 USB0_HOST_PRSNT A103 LID# B103 SLEEP#
A49 GBE0_SDP B49 SYS_RESET# A104 VCC_12V B104 VCC_12V
A50 LPC_SERIRQ/ESPI_CS1# B50 CB_RESET# A105 VCC_12V B105 VCC_12V
A51 GND (FIXED) B51 GND (FIXED) A106 VCC_12V B106 VCC_12V
A52 PCIE_TX5+ B52 PCIE_RX5+ A107 VCC_12V B107 VCC_12V
A53 PCIE_TX5- B53 PCIE_RX5- A108 VCC_12V B108 VCC_12V
A54 GPI0 B54 GPO1 A109 VCC_12V B109 VCC_12V
A55 PCIE_TX4+ B55 PCIE_RX4+ A110 GND (FIXED) B110 GND (FIXED)

Copyright © 2018 congatec AG TEVA2m11 16/56


4.2 COM Express C - D Connector
Table 4 Module Type 6 Connector Pinout—Rows C and D

Pin Row C Pin Row D Pin Row C Pin Row D


C1 GND (FIXED) D1 GND (FIXED) C56 PEG_RX1- D56 PEG_TX1-
C2 GND D2 GND C57 TYPE1# D57 TYPE2#
C3 USB_SSRX0- D3 USB_SSTX0- C58 PEG_RX2+ D58 PEG_TX2+
C4 USB_SSRX0+ D4 USB_SSTX0+ C59 PEG_RX2- D59 PEG_TX2-
C5 GND D5 GND C60 GND (FIXED) D60 GND (FIXED)
C6 USB_SSRX1- D6 USB_SSTX1- C61 PEG_RX3+ D61 PEG_TX3+
C7 USB_SSRX1+ D7 USB_SSTX1+ C62 PEG_RX3- D62 PEG_TX3-
C8 GND D8 GND C63 RSVD D63 RSVD
C9 USB_SSRX2- D9 USB_SSTX2- C64 RSVD D64 RSVD
C10 USB_SSRX2+ D10 USB_SSTX2+ C65 PEG_RX4+ D65 PEG_TX4+
C11 GND (FIXED) D11 GND (FIXED) C66 PEG_RX4- D66 PEG_TX4-
C12 USB_SSRX3- D12 USB_SSTX3- C67 RAPID_SHUTDOWN D67 GND
C13 USB_SSRX3+ D13 USB_SSTX3+ C68 PEG_RX5+ D68 PEG_TX5+
C14 GND D14 GND C69 PEG_RX5- D69 PEG_TX5-
C15 DDI1_PAIR6+ D15 DDI1_CTRLCLK_AUX+ C70 GND (FIXED) D70 GND (FIXED)
C16 DDI1_PAIR6- D16 DDI1_CTRLDATA_AUX- C71 PEG_RX6+ D71 PEG_TX6+
C17 RSVD D17 RSVD C72 PEG_RX6- D72 PEG_TX6-
C18 RSVD D18 RSVD C73 GND D73 GND
C19 PCIE_RX6+ D19 PCIE_TX6+ C74 PEG_RX7+ D74 PEG_TX7+
C20 PCIE_RX6- D20 PCIE_TX6- C75 PEG_RX7- D75 PEG_TX7-
C21 GND (FIXED) D21 GND (FIXED) C76 GND D76 GND
C22 PCIE_RX7+ D22 PCIE_TX7+ C77 RSVD D77 RSVD
C23 PCIE_RX7- D23 PCIE_TX7- C78 PEG_RX8+ D78 PEG_TX8+
C24 DDI1_HPD D24 RSVD C79 PEG_RX8- D79 PEG_TX8-
C25 DDI1_PAIR4+ D25 RSVD C80 GND (FIXED) D80 GND (FIXED)
C26 DDI1_PAIR4- D26 DDI1_PAIR0+ C81 PEG_RX9+ D81 PEG_TX9+
C27 RSVD D27 DDI1_PAIR0- C82 PEG_RX9- D82 PEG_TX9-
C28 RSVD D28 RSVD C83 RSVD D83 RSVD
C29 DDI1_PAIR5+ D29 DDI1_PAIR1+ C84 GND D84 GND
C30 DDI1_PAIR5- D30 DDI1_PAIR1- C85 PEG_RX10+ D85 PEG_TX10+
C31 GND (FIXED) D31 GND (FIXED) C86 PEG_RX10- D86 PEG_TX10-
C32 DDI2_CTRLCLK_AUX+ D32 DDI1_PAIR2+ C87 GND D87 GND
C33 DDI2_CTRLDATA_AUX- D33 DDI1_PAIR2- C88 PEG_RX11+ D88 PEG_TX11+
C34 DDI2_DDC_AUX_SEL D34 DDI1_DDC_AUX_SEL C89 PEG_RX11- D89 PEG_TX11-
C35 RSVD D35 RSVD C90 GND (FIXED) D90 GND (FIXED)

Copyright © 2018 congatec AG TEVA2m11 17/56


Pin Row C Pin Row D Pin Row C Pin Row D
C36 DDI3_CTRLCLK_AUX+ D36 DDI1_PAIR3+ C91 PEG_RX12+ D91 PEG_TX12+
C37 DDI3_CTRLDATA_AUX- D37 DDI1_PAIR3- C92 PEG_RX12- D92 PEG_TX12-
C38 DDI3_DDC_AUX_SEL D38 RSVD C93 GND D93 GND
C39 DDI3_PAIR0+ D39 DDI2_PAIR0+ C94 PEG_RX13+ D94 PEG_TX13+
C40 DDI3_PAIR0- D40 DDI2_PAIR0- C95 PEG_RX13- D95 PEG_TX13-
C41 GND (FIXED) D41 GND (FIXED) C96 GND D96 GND
C42 DDI3_PAIR1+ D42 DDI2_PAIR1+ C97 RVSD D97 RSVD
C43 DDI3_PAIR1- D43 DDI2_PAIR1- C98 PEG_RX14+ D98 PEG_TX14+
C44 DDI3_HPD D44 DDI2_HPD C99 PEG_RX14- D99 PEG_TX14-
C45 RSVD D45 RSVD C100 GND (FIXED) D100 GND (FIXED)
C46 DDI3_PAIR2+ D46 DDI2_PAIR2+ C101 PEG_RX15+ D101 PEG_TX15+
C47 DDI3_PAIR2- D47 DDI2_PAIR2- C102 PEG_RX15- D102 PEG_TX15-
C48 RSVD D48 RSVD C103 GND D103 GND
C49 DDI3_PAIR3+ D49 DDI2_PAIR3+ C104 VCC_12V D104 VCC_12V
C50 DDI3_PAIR3- D50 DDI2_PAIR3- C105 VCC_12V D105 VCC_12V
C51 GND (FIXED) D51 GND (FIXED) C106 VCC_12V D106 VCC_12V
C52 PEG_RX0+ D52 PEG_TX0+ C107 VCC_12V D107 VCC_12V
C53 PEG_RX0- D53 PEG_TX0- C108 VCC_12V D108 VCC_12V
C54 TYPE0# D54 PEG_LANE_RV# C109 VCC_12V D109 VCC_12V
C55 PEG_RX1+ D55 PEG_TX1+ C110 GND (FIXED) D110 GND (FIXED)

4.3 Power Supply Connector


The conga-TEVAL/COMe 3.0 provides the following connectors for power supply:
•• standard 24-pin ATX connector (X63)
•• 12 V DC banana jack (X41 and X42)
Note

1. In ATX mode, the +3.3 V, +5 V and +12 V are derived from the ATX power supply. If you supply 12 V DC power via the DC banana jack,
the onboard DC/DC regulators will generate the 3.3 V, 5 V and 12 V.

2. Do not supply power to both the DC banana jack and the ATX connector at the same time.

Copyright © 2018 congatec AG TEVA2m11 18/56


4.3.1 ATX Power Connector
The conga-TEVAL/COMe 3.0 provides a standard 24-pin connector X63 for ATX power supply. With ATX power supply, the COM Express™
module starts after you press the power-on button SW16 (ATX mode). To configure the power supply to operate in AT mode, set DIP SW21.1
to ON. In this mode, the module starts after the power switch on the power supply is turned on.

Use jumper JP11 to disconnect the 5 V standby voltage from the whole system.

Table 5 X63 - ATX Power

Pin Signal Description Pin Signal Description


1 +3.3V Power supply +3.3 VDC 13 +3.3V Power supply +3.3 VDC
2 +3.3V Power supply +3.3 VDC 14 -12V Power supply -12 VDC
3 GND Power ground 15 GND Power ground X63
4 +5V Power supply +5 VDC 16 PS_ON# Power Supply On (active low). Short this
pin to GND to switch power supply ON;
disconnect from GND to switch OFF.
5 GND Power ground 17 GND Power ground
6 +5V Power supply +5 VDC 18 GND Power ground
7 GND Power ground 19 GND Power ground
8 PWR_OK Power Ok 20 N.C
9 5V_SB Standby power supply +5 VDC 21 +5V Power supply +5 VDC
10 +12V Power supply +12 VDC 22 +5V Power supply +5 VDC
11 +12V Power supply +12 VDC 23 +5V Power supply +5 VDC
12 +3.3V Power supply +3.3 VDC 24 GND Power ground

Note

1. The -5V power output of the ATX power supply is not used.

2. The carrier board supports only 24-pin ATX power supply.

Table 6 SW21.1 - ATX PSU Control Description


SW21 SW16
Setting Configuration
2

0N
OFF ATX mode (default)
1
ON AT mode

Copyright © 2018 congatec AG TEVA2m11 19/56


Table 7 JP11 - ATX 5V Standby Connection

Pin Description JP11


1-2 5V standby connected (default) 1 2 3

2-3 5V standby disconnected

Connector Type

X63: Standard 24-pin ATX connector

4.3.2 DC Banana Jack


The conga-TEVAL/COMe 3.0 provides banana jacks X41 and X42 for DC power supply. This power supply supplies power to both the module
and the voltage regulators on the carrier board. Although the carrier board is designed for input voltage range of 6 -21 V, the input voltage
range is defined by the module (usually 12 V).

Caution
X41 X42

Do not exceed the voltage rating of the COM Express module. Doing so, will damage the module.

Table 8 X41/X42 - DC Banana Jack

Connector Description
X41 Input voltage for module and carrier board (usually +12 V)
X42 Ground

Table 9 SW21.2 - 12 V Voltage Regulator Control (Only via DC Banana Jack)


SW21
Setting Description
OFF Enable (default) 2

0N
ON Disable 1

Connector Type

X41, X42: 4 mm diameter plug

Copyright © 2018 congatec AG TEVA2m11 20/56


4.3.3 Status LEDs D68-D72, D84-D86
The status LEDs indicate the different power states of the conga-TEVAL/COMe 3.0. You can connect an external power LED to pin header X58.

Table 10 Power LEDs Status


X58 D84 D85 D86
LED Status Description
1
All Off No power applied.
All On ATX power supply is fully switched on, with stable 3.3 V, 5 V and 12 V.
2
D84 On The green LED indicates the status of SUS_S3#
D70 D71 D72
D85 On The green LED indicates the status of SUS_S4#
D86 On The green LED indicates the status of SUS_S5#
D70 On The green LED indicates that 12 V main power is present
D71 On The green LED indicates that 5 V main power is present
D68 D69
D72 On The green LED indicates that the onboard 3.3 V main power is present
D68 On The yellow LED indicates that the onboard 3.3 V standby power is present
D69 On The yellow LED indicates that 5V standby power is applied to the conga-TEVAL/COMe 3.0. If only D69
lights, it indicates that the ATX power supply is mechanically switched on and only 5 V standby power is
applied to the conga-TEVAL/COMe 3.0.

4.3.4 PWR_OK Signal


The PWR_OK signal is a high-active input from the main power supply to the module and it indicates whether the power is good. Use jumper
JP9 to configure the PWR_OK signal.

Table 11 JP9 - Module PWR_OK Selection


JP9
Pin Description
1-2 Add 3.3V pull-up with 1 kΩ to PWR_OK signal (for debug purposes)

4
2

6
3-4 Connect PWR_OK signal from ATX power supply (default)
5-6 Connect PWR_OK signal from onboard DC/DC regulator (only via DC banana jack)

5
Connector Type

JP9: 2.54 mm, 2-pin jumper

Copyright © 2018 congatec AG TEVA2m11 21/56


4.3.5 Power-Up Control
The module’s SUS_S3# signal controls the ATX power supply control signal (PS_ON#). When the system goes to Suspend to RAM (S3) or
Soft Off (S5), the module’s chipset asserts the ‘SUS_S3#’ signal. Through the use of an inverter, the low active ‘PS_ON#’ signal goes high and
switches off the ATX power supply.

When the system is in a power-down system state, any system wake-up event invokes the chipset of the module to deassert the ‘SUS_S3#’
signal. With the deassertion, the system transitions to Full-On state (S0).

4.3.6 Power Consumption Header


The conga-TEVAL/COMe 3.0 offers optional pin headers X3 and X4 for measuring the power consumption of the COM Express module

Table 12 X3/X4 - Power Consumption Measurement


X3 (Optional) X4 (Optional)
X3 Signal X4 Signal
1 VCC12V 1 VCC5V_SBY 1 2

1
2 VCC12V_COME 2 VCC5V_SBY_COME

Connector Type

2
X3,X4: 2.54mm, 1 x 2-pin header

4.3.7 Module Type Detection


The signals TYPE0#, TYPE1#, TYPE2# and TYPE10# indicate the pinout type of the module connected to the carrier board. These pins are either
open (N.C), strapped to ground (GND) or connected to 12 V by the module as shown in the table below.

Table 13 Module Type Detection Pinout Description

TYPE0# TYPE1# TYPE2# TYPE10# Comment


Module Type 1 X (don't care) X (don't care) X (don't care) 12V/NC COM Express Specification 1.0/2.0
Module Type 10 X (don't care) X (don't care) X (don't care) 47k PD COM Express Specification 2.0
Module Type 2 NC NC NC 12V/NC COM Express Specification 1.0/2.0
Module Type 3 NC NC GND 12V/NC COM Express Specification 1.0/2.0
Module Type 4 NC GND NC 12V/NC COM Express Specification 1.0/2.0
Module Type 5 NC GND GND 12V/NC COM Express Specification 1.0/2.0

Copyright © 2018 congatec AG TEVA2m11 22/56


Module Type 6 GND NC NC NC COM Express Specification 2.0/3.0
Module Type 7 GND N.C GND N.C COM Express Specification 3.0

Note

If the conga-TEVAL/COMe 3.0 detects an incompatible module pinout, an onboard logic prevents the board from powering up the whole
system by controlling the ‘PS_ON#’ signal of the ATX power supply.

4.4 CMOS Battery Holder


The conga-TEVAL/COMe 3.0 provides holder M30 for attaching a CR2032 CMOS battery. The battery supplies power to the RTC and CMOS
memory. To disconnect the RTC battery, set jumper JP8 to position 2-3.
JP8 M30
Table 14 JP8 - RTC Battery Connection
1 2 3

Pin Description
1-2 Connect RTC battery (default)
2-3 Disconnect the RTC battery

Warning

Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer’s instructions.

Copyright © 2018 congatec AG TEVA2m11 23/56


4.5 PCIe Connectors
The conga-TEVAL/COMe 3.0 provides:
•• one PEG x16 slot connector X6 (PEG lanes 0–15)
•• one x4 PCIe slot connector X9 (PCIe lanes 0–3)
•• five x1 PCIe slot connectors X7,X8,X10,X14 and X19 (PCIe lanes 1–3, 5 and 7)
•• one M.2 key B socket connector X12 (PCIe lanes 4 and 5)
•• one mPCIe socket connector X16 (PCIe lane 6)
The PCIe lanes are routed as shown below:

M.2 Slot 4 (X12) SIM Card Slot (X13)


x4 lanes - Slot 0 (X9)
PCIe Lane 0 PCIe Lane 4
PCIe Lane 1
PCIe Lane 2 PCIe Lane 5

Mux (via DIP SW 2


PCIe Lane 3

x1 Slot 1 (X10) x1 Slot 5 (X14)


Mux (via DIP SW 1)

PCIe Lane 1 PCIe Lane 5

x1 Slot 2 (X7) Mini PCIe (X16) SIM Card Slot (X15)


PCIe Lane 2 PCIe Lane 6

x1 Slot 3 (X8) x1 Slot 6 (X19)

PCIe Lane 3 PCIe Lane 7

Copyright © 2018 congatec AG TEVA2m11 24/56


4.5.1 PEG x16 Slot
X6
The conga-TEVAL/COMe 3.0 provides a PEG port on a standard PCIe x16 slot connector (X6).
Connector Type

X6: PCIe x16 card

4.5.2 PCIe x4 Slot


The conga-TEVAL/COMe 3.0 provides a standard PCIe x4 slot connector X9 (Slot 0). This slot, which is routed to the module’s PCIe lanes 0–3,
shares:
•• PCIe lane 1 with connector X10 (Slot 1)
•• PCIe lane 2 with connector X7 (Slot 2)
•• PCIe lane 3 with connector X8 (Slot 3)
PCIe Slot 0 supports one PCIe lane (x1 link) by default. For x2 or x4 link, set DIP SW1 as described in the table below:

Table 15 SW1 - PCIe x4 Slot Configuration

SW1 SW2 Description X9 SW1


OFF OFF x1 PCIe link (default) 2

0N
OFF ON x2 PCIe link 1
ON ON x4 PCIe link

Note

You must also configure the PCIe link on the module.


Connector Type

X9: PCIe card

Copyright © 2018 congatec AG TEVA2m11 25/56


4.5.3 PCIe x1 Slot
The conga-TEVAL/COMe 3.0 provides five standard PCIe x1 slots. The table below shows how the signals are routed to the connectors:

Table 16 PCIe x1 Lane Routing

Slot Number PCIe Lane Connector


X7, X8, X10, X14, X19
Slot 1 PCIe 1 X10
Slot 2 PCIe 2 X7
Slot 3 PCIe 3 X8
Slot 5 PCIe 5 X14
Slot 7 PCIe 7 X19

Connector Type

X7-X10; X14; X19: PCIe x1 card

4.5.4 Mini PCIe Socket


The conga-TEVAL/COMe 3.0 provides a standard mini PCIe socket connector X16. This socket is routed to the module’s PCIe lane 6 and USB
port 5. The LEDs D6–D8 indicate activity of the card attached to the socket.

The UIM interface of the mini PCIe socket is connected to a micro-SIM card slot (X15).
X16 D6 D7 D8
Table 17 D6-D8 - mini PCIe LEDs Description

LED Description
D6 Wireless Wide Area Network
D7 Wireless Local Area Network X15
D8 Wireless Personal Area Network

Connector Type

X16: mPCIe card

X15: Micro SIM card

Copyright © 2018 congatec AG TEVA2m11 26/56


4.5.5 M.2
The conga-TEVAL/COMe 3.0 provides a standard M.2 Key B slot connector X12. The slot is routed to the module’s PCIe lanes 4 and 5, and USB
port 4. It supports WWAN and Intel Optane memory devices. LED D3 lights when there is activity on the M.2 port.

The M.2 connector shares PCIe lane 5 with PCIe Slot 5 (X1). To use the M.2 connector, you must set DIP SW2.1 to ON. For additional M.2
configurations, see tables 17 “SW3 Configuration” and 18 “SW4 Configuration” below.

The UIM interface of the M.2 socket is connected to a micro-SIM card slot (X13).

Table 18 SW2.1 - PCIe Lane 5 Configuration


SW2 X13
Setting Description
2

0N
OFF Routes PCIe lane 5 to connector X1 - PCIe slot 5 (default)
1
ON Routes PCIe lane 5 to M.2 connector

Table 19 SW3 - M.2 Configuration

Switch Configuration Description SW3 D3

O
N
SW3.1 OFF Disconnect M.2 SMB_ALERT# (default)

1
2
3
4
ON Connect M.2 SMB_ALERT#
SW3.2 OFF Disconnect WOWWAN# (default)
ON Connect WOWWAN#
SW3.3 OFF Connect M.2 SMB_DAT/CLK (default) X12
ON Disconnect M.2 SMB_DAT/CLK
SW3.4 OFF Deactive M.2 full card power-off control
ON Activate M.2 full card power-off control

Table 20 SW4 - M.2/mini PCIe Configuration

Switch Configuration Description SW4

O
N
SW4.1 OFF Enable mPCIe wireless (default)

1
2
3
4
ON Disable mPCIe wireless

Copyright © 2018 congatec AG TEVA2m11 27/56


SW4.2 OFF Deactivate M.2 reset control (default)
ON Activate M.2 reset control
SW4.3 OFF Deactivate M.2 WDIS2# control - wireless 2 (default)
ON Activate M.2 WDIS2# control
SW4.4 OFF Deactivate M.2 WDIS1# control - wireless 1 (default)
ON Activate M.2 WDIS1# control

Connector Type

X12: M.2 Key B card size 3042, 2242, 2260, 2280

X13: Micro SIM card

4.6 SD Card Slot


The conga-TEVAL/COMe 3.0 features a full-size SD card slot connector X28. The slot is routed to the module’s SDIO interface, which is
multiplexed with GPIO. The conga-TEVAL/COMe 3.0 demultiplexes the shared signals, and routes the demultiplexed signals to either the SD
card slot (SDIO mode) or the feature connector (GPIO mode).

Use DIP SW5.2 to select SDIO or GPIO mode.


SW5 X28
Table 21 SW 5.2 - GPIO/SDIO Connection
2

0N
1
Setting Description
OFF GPIO mode (default)
ON SDIO mode

Connector Type

X28: SD Card

Copyright © 2018 congatec AG TEVA2m11 28/56


4.7 Display Interfaces
The conga-TEVAL/COMe 3.0 provides the following display interfaces:

4.7.1 VGA
The conga-TEVAL/COMe 3.0 provides a VGA interface on standard 15-pin DSUB connector X45. X45
Connector Type 5 1

X45: 15-pin, high density DSUB male 15 11

4.7.2 DP++
The conga-TEVAL/COMe 3.0 provides three DP++ interfaces on connectors X35, X36 and X37. The DP++ ports on connector X35 (port 0) and
connector X37 (port 3) are routed through a DisplayPort re-driver to support HBR3 data rate (up to 8.1 Gbps).

You can connect a DP++ to HDMI dongle to the DP++ connectors if your module supports it. X35, X36, X37
Connector Type

X35, X36, X37: Standard DP cable

4.7.3 LVDS/eDP
The conga-TEVAL/COMe 3.0 connects the module’s LVDS/eDP interface to:
•• eDP panel on connector X39
•• LVDS panel on connector X38
Use DIP SW8.1 to select the option for eDP or LVDS panel.

Table 22 SW8.1 - eDP/LVDS Selection


SW8
Setting Configuration 2

0N
ON eDP selection 1
OFF LVDS selection (default)

Copyright © 2018 congatec AG TEVA2m11 29/56


4.7.3.1 eDP

For eDP functionality on connector X39, set DIP SW8.1 to ON.

Table 23 X39 - eDP Pinout Description

Pin Signal Pin Signal SW8


1 N.C. 21 PANEL_PWR X39 2

0N
2 GND 22 N.C. 1
3 eDP_TX3- 23 GND
4 eDP_TX3+ 24 GND
5 GND 25 GND
6 eDP_TX2- 26 GND
7 eDP_TX2+ 27 eDP_HPD
8 GND 28 GND
9 eDP_TX1- 29 GND
10 eDP_TX1+ 30 GND
11 GND 31 GND
12 eDP_TX0- 32 eDP_LVDS_BKLT_EN
13 eDP_TX0+ 33 eDP_LVDS_BKLT_CTRL
14 GND 34 N.C.
15 eDP]_AUX+ 35 N.C.
16 eDP_AUX- 36 N.C
17 GND 37 BKLT_PWR
18 PANEL_PWR 38 BKLT_PWR
19 PANEL_PWR 39 BKLT_PWR
20 PANEL_PWR 40 N.C.

Connector Type

X39: 0.5 mm , 40 Pos. ACES series 50204 connector

Copyright © 2018 congatec AG TEVA2m11 30/56


4.7.3.2 LVDS

For LVDS functionality on connector X38, set DIP SW8.1 to OFF.

Table 24 X38 - LVDS Pinout Description

Pin Signal Pin Signal


1 LVDS_DDC_DAT 18 LVDS0_D3+
2 LVDS_DDC_CLK 19 LVDS0_D3-
3 N.C 20 GND
4 N.C 21 LVDS1_D0- X38 SW8
5 GND 22 LVDS1_D0+ 2

0N
6 LVDS0_D0- 23 GND 1
7 LVDS0_D0+ 24 LVDS1_D1-
8 LCD0_VDD_EN 25 LVDS1_D1+
9 LVDS0_D1- 26 GND
10 LVDS0_D1+ 27 LVDS1_D2-
11 LCD0_BKLTEN 28 LVDS1_D2+
12 LVDS0_D2+ 29 GND
13 LVDS0_D2- 30 LVDS1_CLK+
14 NC 31 LVDS1_CLK
15 LVDS0_CLK- 32 NC
16 LVDS0_CLK+ 33 LVDS1_D3+
17 NC 34 LVDS1_D3-

Connector Type

X38: 2 mm, 2 x 17-pin socket

Copyright © 2018 congatec AG TEVA2m11 31/56


4.7.3.3 LVDS Panel and Backlight Power Supply

The power supply for LVDS panels and backlight inverter is available on connector X40.

Table 25 X40 - LVDS Power Pinout Description

Pin Signal Pin Signal


1 VDD_LCD (2.0 A fuse) 2 VDD_BKLT (1.5 A fuse) X40
3 +5V (2.0 A fuse) 4 +12V (1.5 A fuse) 2 4 6 8 10
5 LCD_VDD_EN 6 LCD_BKLT_EN 1 3 5 7 9
7 N.C 8 LCD_BKLT_PWM
9 GND 10 GND

Connector Type

X40: 2.54 mm, 2 x 5-pin female connector

4.7.3.4 Flat Panel and Backlight Voltage Selection

The conga-TEVAL/COMe 3.0 supports different voltages for the panel and backlight. Follow the descriptions in the tables below to set the
panel and backlight voltages, and the polarity of the backlight enable signal.

Table 26 JP3 - Flat Panel Voltage Selection

Pin Configuration JP3


1-2 5 V panel power (default) 1 2 3

2-3 3.3 V panel power

Table 27 JP4 - Backlight Voltage Selection

Pin Configuration JP4


1-2 12 V backlight Power (default)
1 2 3
2-3 5 V backlight Power

Copyright © 2018 congatec AG TEVA2m11 32/56


Table 28 SW8.2 - Backlight Enable Signal Configuration
SW8
Setting Configuration
2
ON Inverted BKLT_EN signal

0N
1
OFF Non-inverted BKLT_EN signal (default)

Connector Type

JP3, JP4: 2.54 mm grid jumper

4.7.3.5 Flat Panel and Backlight Power Supply Connection

X40
2.0A
+12V [4] +12V
1.5A
+5V [3] +5V

+3.3V
JP4 1 2 3
JP3 1 2 3

LVDS_VDD_EN

1.5A
LFP_BKLT_EN_SEL
ON
[1] VDD_LCD

1 2
[5] LCD0_VDD_EN
2.0A
SW8 [2] VDD_BKLT
[6] LCD0_BKLT_EN
LVDS_BKLT_CTRL
[8] LCD0_BKLT_PWM

[9] GND
[10] GND

Copyright © 2018 congatec AG TEVA2m11 33/56


4.7.3.6 Flat Panel Configuration Data

The flat panel configuration data (EPI extended EDID™ 1.3 file) for most common displays is included in the congatec COM Express™ CPU
module’s system BIOS.

On the conga-TEVAL/COMe 3.0, you can store a customized EPI extended EDID™ 1.3 file in a serial EEPROM located on DIL SOIC8 socket
U35. The following EEPROMs are supported at address A0h:
U35
•• 24C02
•• 24C04
•• 24C16
Connector Type

U35: EEPROM in 8-pin DIL package

4.8 Universal Serial Bus (USB)


The conga-TEVAL/COMe 3.0 provides the following USB connectors:
•• two dual-stacked USB 3.1 Type-A
–– USB ports 0 and 1 on connector X29
–– USB ports 2 and 3 on connector X30
•• USB Type B (connector X31)
•• two USB 2.0 Type A ports (connector X32)
The COM Express USB signals are routed to the connectors as shown on the next page:

Copyright © 2018 congatec AG TEVA2m11 34/56


Port 0 (USB 3.1)
X29 - Dual Stacked
Port 1 (USB 3.1) USB Type A

Port 2 (USB 3.1)


X30 - Dual Stacked
Port 3 (USB 3.1) USB Type A

COM Express Connector


Port 0 (USB 2.0 Client)
X31 - USB Type B

Port 6 (USB 2.0)


X32 - LAN with Dual
Port 7 (USB 2.0) USB Type A

Port 5 (USB 2.0)


X16 - mini PCIe

Port 4 (USB 2.0)


X12 - M.2

4.8.1 Dual Stacked USB 3.1 Type-A


The conga-TEVAL/COMe 3.0 provides four USB 3.1 ports via two dual-stacked USB Type-A connectors (X29 and X30). Each port provides up to
one ampere. The lower slot of connector X29 shares the module’s USB port 0 signals with the USB client port (connector X31).

Use DIP SW5.1 to route the shared signals to either connector X29 (host port) or connector X31 (client port).

Table 29 SW5.1 - USB Port 0 Configuration X29 X30 SW5


2
Setting Configuration

0N
USB 3.0 USB 3.0
1
OFF USB port 0 to connector X29—host mode (default)
ON USB port 0 to connector X31—client mode USB 3.0 USB 3.0

Note

Lower slot of connector X29 will not function if you set SW1 to ON (client mode).
Connector Type

X29, X30: USB Type A plug


Copyright © 2018 congatec AG TEVA2m11 35/56
4.8.2 USB Type-B (Client Mode)
The conga-TEVAL/COMe 3.0 provides a USB 2.0 Type B connector X31 for USB client mode. Its USB signals are shared with USB port 0 (lower
slot of USB connector X29). Use DIP SW5.1 to route the shared signals to connector X31 (client port). For DIP SW5.1 configuration, see table 27
“SW 5.1 Description”.
X31 SW5
2

0N
1

Note

Connector X31 will not function if:

1. the module does not support USB client mode

2. you set SW1 to OFF (host mode).


Connector Type

X31: USB Type B plug

4.8.3 Dual Stacked USB 2.0 Type-A


The conga-TEVAL/COMe 3.0 provides two USB 2.0 ports via connector X32—a modular RJ45 connector stacked with dual USB 2.0 ports. Each
USB port provides up to 500 mA.
X32

8765432 1

USB Port 7
USB Port 6

Connector Type

X32: USB Type A plug

Copyright © 2018 congatec AG TEVA2m11 36/56


4.9 SATA/SATADOM
The conga-TEVAL/COMe 3.0 provides four standard SATA connectors (X20 - X23). SATADOM devices are supported on only connector X20
(SATA0). To enable SATADOM on X20, set jumper JP1 to position 2-3. The 5 V power rail on SATA0 pin 7 (SATADOM mode) is protected by
0.5A fuse.

The SATA activity LED (D9) lights when an activity occurs on any of the SATA interfaces. The pin header X26 provides an option to connect
external SATA activity LED.

Table 30 JP1 - SATA/SATADOM Configuration

Pin Configuration JP1 D9


1-2 SATA - pulls SATA0 pin 7 to ground (default) 1 2 3

2-3 SATADOM - pulls SATA0 pin 7 to 5V

Table 31 X26 - External SATA Activity LED


X26
X20 X21 X22 X23
Pin Signal
1
1 Anode 7 6 5 4 3 2 1 7 6 5 4 3 2 1 7 6 5 4 3 2 1 7 6 5 4 3 2 1

2 Cathode SATA0 SATA2


2 SATA1 SATA3

Connector Type

X26: 2.54 mm, 1 x 2-pin socket

4.9.1 Disk Drive Power Connector


X25
The conga-TEVAL/COMe 3.0 provides connector X25, a 4-pin connector for powering disk drives.

Caution

Do not connect more than one peripheral device to connector X25. The peripherals may damage if you do so.
Connector Type

X25: 4-pin power connector


Copyright © 2018 congatec AG TEVA2m11 37/56
4.9.2 SATA Power
The conga-TEVAL/COMe 3.0 provides a standard 15-pin SATA power connector (X24) for hard drives. This connector supplies 3.3 V, 5 V and
12 V.

Table 32 X24 - SATA Power Pinout Description

Pin Signal Pin Signal Pin Signal


1 3.3 V 6 GND 11 GND X24
2 3.3 V 7 5V 12 GND
3 3.3 V 8 5V 13 12 V 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

4 GND 9 5V 14 12 V
5 GND 10 GND 15 12 V

Connector Type

X24: 15-pin standard SATA power connector

4.10 Gigabit Ethernet (GbE)


The conga-TEVAL/COMe 3.0 provides a gigabit Ethernet port on a standard RJ45 connector (X32). Use jumper JP2 to set the power rail for the
status LEDs on connector X32.

Table 33 GbE (X32) Status LEDs


X32
Color Description
Yellow Link activity
Orange 100 Mb link
8765432 1

USB Port 7
Green 1000 Mbit link
USB Port 6

Table 34 JP2 - Ethernet LEDs Power Configuration

Pin Configuration JP2


1-2 Status LEDs are powered by standby voltage (default) 1 2 3

Copyright © 2018 congatec AG TEVA2m11 38/56


2-3 Status LEDs are powered by runtime voltage

Table 35 X33 - Ethernet SDP


X33
Pin Configuration
1 2
1 SDP signal
2 Ground

Connector Type

X16: 2.54 mm grid jumper


X32: RJ45 cable plug
X33: 2-pin picoBlade 1.25 mm pitch receptacle

4.11 Audio Interfaces


The conga-TEVAL/COMe 3.0 features:

1. a multi-channel low power HD audio codec (Cirrus CS4207). The codec supports:
–– MIC-In signals on connector X47 (lower jack)
–– Line-Out signals on connector X47 (upper jack)
–– Optical S/PDIF output signal on connector X48
2. an HDA adapter/debug header on connector X49
Note

1. To disable the onboard codec, set DIP SW 9.2 to ON. See section 4.11.4 “HDA Adapter/Debug Header” for DIP SW 9.2 configuration .

2. The Windows driver for the codec can be found on the congatec website at www.congatec.com in the ‘Products’ section under ‘Accessories.

Copyright © 2018 congatec AG TEVA2m11 39/56


4.11.1 MIC-In
Table 36 MIC-In (X47) Pinout Description X47 Jack (MIC-IN)

Tip
Pin Jack Signal Description Ring
1 Tip MIC_L Microphone - left channel LINE-OUT
Sleeve
2 Ring MIC_R Microphone - right channel
3 Sleeve A_GND Analog ground MIC-IN

Connector Type

X47 Lower Jack: 3-pin, 3.5 mm single audio jack

4.11.2 Line-Out
Table 37 Line-Out (X47) Pinout Description X47 Jack (Line-IN)

Tip
Pin Jack Signal Description
Ring
1 Tip LINE_L Line-OUT - left channel
LINE-OUT Sleeve
2 Ring LINE_R Line-OUT - right channel
3 Sleeve A_GND Analog ground MIC-IN

Connector Type

X47 Upper Jack: 3-pin, 3.5 mm single audio jack

4.11.3 Optical S/PDIF-Out


X48
The conga-TEVAL/COMe 3.0 provides S/PDIF-OUT signal on connector X48.
Connector Type

X48: TOSLINK Optical cable

Copyright © 2018 congatec AG TEVA2m11 40/56


4.11.4 HDA Adapter/Debug Header
The HDA adapter X49 makes it possible to connect other HDA solutions to the conga-TEVAL/COMe 3.0. Use DIP SW9.2 to disable the onboard
HDA codec.

Table 38 SW9.2 - HDA Codec Configuration


SW9
Setting Configuration
2
OFF Enable audio codec (default)

0N
1
ON Disable audio codec

Table 39 X49 - HDA Adapter Pinout Description

Pin Signal Description Pin Signal Description


1 +12V 12 V DC power supply with 750 mA fuse 2 +3.3V 3.3 V DC power suppy with 750 mA fuse
3 HDA_SYNC 48kHz fixed-rate, sample-synchronization 4 HDA_RST# Reset output to CODEC, active low X49
signal to the CODEC(s)
5 HDA_SDIN Serial TDM data inputs from up to three 6 HDA_BITCLK 12.228 MHz serial data clock generated by the

10

9
CODECs external CODEC.

7
7 HDA_SDOUT Serial TDM data output to the CODEC 8 CODECSET Onboard codec disable input. Pull high to disable

5
(Input 3.3V) onboard audio codec

3
9 GND Power Ground 10 GND Power Ground

1
Connector Type

X49: 2x 5-pin, 2.54 mm grid female

4.12 SM Bus
The SM Bus signals are available on the feature connector X56 described in section 4.23 “Feature Connector”. The SM Bus on the module is
powered by the standby power rail. To avoid current leakage, the conga-TEVAL/COMe 3.0 features a FET switch that isolates the SMB devices
that are powered by the main power rail.

Copyright © 2018 congatec AG TEVA2m11 41/56


4.13 I2C Bus
The I²C signals are available in different locations on the conga-TEVAL/COMe 3.0, including on the feature connector X56 described in section
4.23. The conga-TEVAL/COMe 3.0 includes socket U50 for attaching an I²C EEPROM for test purposes during the system development.

The 8-pin DIL socket supports various 2-wire 3.3 V serial EEPROMS such as 24C04, 24C08 and 24C16. Use the I²C control commands implemented
in the congatec CGOS API driver to access the EEPROMs. For more information, refer to the CGOS manual and the user’s guide of the COM
Express module.
U50
Connector Type

U50: EEPROM in 8-pin DIL package

4.14 SPI Bus


The conga-TEVAL/COMe 3.0 provides an 8-pin SOIC8 socket (U48) for an SPI flash. Use DIP SW14 to select the flash device to boot from.

Table 40 SW14 - BIOS Boot Device Selection


U48 SW14
SW1 SW2 Configuration
2
OFF OFF Boot from on-module firmware (default)

0N
1
OFF ON Boot from carrier board SPI Flash
ON OFF Not supported
ON ON Boot from on-module firmware, but load management data from carrier SPI

Connector Type

U48: SPI flash in 8-pin 200 mil SOIC8 package

Copyright © 2018 congatec AG TEVA2m11 42/56


4.15 LPC/eSPI
On the conga-TEVAL/COMe 3.0, the module’s LPC/eSPI interface is routed to:
•• LPC/TPM header (connector X51)
•• LPC/eSPI Super I/O controller
The Super I/O controller provides the following interfaces:
•• Serial ports (connector X52 and X53)
•• 3-pin System fan (jumper JP6)
Use DIP SW10.1 to enable or disable the Super I/O functionality and DIP SW10.2 to choose the communication mode (LPC or eSPI).

Table 41 SW10.1 - Super I/O Control

Setting Description
ON Enable Super I/O (default) SW10
OFF Disable Super I/O 2

0N
1

Table 42 SW10.2 - LPC/eSPI Mode Control

Setting Description
ON Select eSPI mode
OFF Select LPC mode (default)

Note

1. These interfaces will not function if the COM Express module does not support them.

2. DIP SW10.2 controls the eSPI_ENA# signal which the conga-TEVAL/COMe 3.0 uses to set the operating mode of the LPC/eSPI bus.

3. The eSPI mode is currently not supported by default.

Caution

Do not set DIP SW10.2 to ON if your module does not support eSPI mode.
Copyright © 2018 congatec AG TEVA2m11 43/56
Table 43 SW11 - Super IO Configuration

Switch Configuration Description


SW11.1 OFF Configuration IO address 2Eh (default)
ON Configuration IO address 4Eh SW11

O
N
SW11.2 OFF Super IO key selection 87h (default)

1
2
3
4
ON Super IO key selection 88h
SW11.3 OFF Disables Super IO Port 80 control (default)
ON Enables Super IO Port 80 control
SW11.4 OFF Selects eSPI_CS0# for Super IO in eSPI mode (default)
ON Selects eSPI_CS1# for Super IO in eSPI mode

4.16 LPC/TPM Header


The LPC/eSPI interface from the module is also routed to connector X51. Connector X51—a 14-pin header—optionally supports TPM modules
that are compliant with the LPC specification (BOM option).

Use DIP SW10.2 to select LPC or eSPI mode. For description of the DIP SW10.2 settings, see table 15 “SW10.2 -LPC/eSPI Mode Control”.

Table 44 X51 - LPC/TPM Pinout Description

Pin Signals Pin Signals X51 SW10


1 2
1 GND 2 LPC_FRAME#/ESPI_CS0# 3 4
2

0N
3 LPC_CLK/ESPI_CLK 4 LPC_AD3/ESPI_IO3 Key
7
6
8
1
5 KEY 6 LPC_AD2/ESPI_IO2 9 10
11 12
7 PLT_RST# 8 LPC_AD1/ESPI_IO1 13 14

9 VCC3V3 10 LPC_AD0/ESPI_IO0
11 SUS_STAT#/ESPI_RST# 12 LPC_SERIRQ/ESPI_CS1#
13 VCC3V3_SBY 14 LPC_DRQ0#/ESPI_ALERT0#

Connector Type

X51: 2.54 mm, 2 x 7-pin socket

Copyright © 2018 congatec AG TEVA2m11 44/56


4.17 Serial Ports (COM Ports)
The conga-TEVAL/COMe 3.0 supports up to four serial ports:
•• COM port 0 on connector X53
•• COM port 1 on connector X52
•• Module serial port 0 (SER0) on feature connector X56
•• Module serial port 1 (SER1) on feature connector X56

4.17.1 COM Port 0 Header


The conga-TEVAL/COMe 3.0 provides COM port 0 on connector X53 via the onboard Super I/O. The port supports RS 232, RS 422 and RS 485
I/O voltage levels. Use DIP SW12 and SW13 to configure the functionality of COM Port 0 transceiver.

Table 45 X53 - COM 0 Pinout Description

Pin Signals Pin Signals X53


1 DCD# 2 DSR

2
3

4
3 RXD 4 RTS#

6
5 TXD 6 CTS#

8
7 DTR# 8 RI#

10
9
9 GND 10 +5V (750mA fuse)

Table 46 SW12 - COM Port 0 Transceiver Configuration


SW12
SW 1 SW 2 Configuration
2
OFF OFF Loopback

0N
1
ON OFF RS-232
OFF ON RS-485 half duplex
ON ON RS-485/RS-422 full duplex

Copyright © 2018 congatec AG TEVA2m11 45/56


Table 47 SW13 - COM Port 0 Slew Rate/Termination

Switch Configuration Description


SW13
SW13.1 OFF 1 Mbps Slew rate
ON 250 kbps Slew rate (for EMI) 2

0N
SW13.2 OFF Disable RS-485/422 termination 1

ON Enable RS-485/422 termination

Connector Type

X53: 2 x 5-pin, 2.54mm grid female

4.17.2 COM Port 1 Header


The conga-TEVAL/COMe 3.0 provides COM port 1 on connector X52 via the onboard Super I/O. The port supports only RS 232 I/O voltage
levels.

Table 48 X52 - COM 1 Pinout Description


X52
Pin Signals Pin Signals

2
1 DCD# 2 DSR

4
3 RXD 4 RTS#

6
5 TXD 6 CTS#

8
7 DTR# 8 RI#

10
9
9 GND 10 +5V (750 mA fuse)

Connector Type

X52: 2 x 5-pin, 2.54 mm grid female

4.17.3 Module Serial Port 0


The module’s serial port 0 (SER0) is connected to pins 41 and 43 of the feature connector on the conga-TEVAL/COMe 3.0. For the feature
connector pinout description, see section 4.23 “Feature Connector”.

Copyright © 2018 congatec AG TEVA2m11 46/56


4.17.4 Module Serial Port 1/CAN Bus
The module’s serial port 1 (SER1)/CAN bus is routed to one of the following connectors:
•• pins 42 and 44 of the feature connector X56
•• CAN bus connector X59, via a CAN transceiver
Use DIP SW2.2 to route the module’s serial port 1 to the feature connector or to the CAN connector. Use jumper JP7 to enable the 120 ohm
CAN bus termination or the CAN bus filter or both.

Table 49 SW2.2 - SER1/CAN Selection


X59
Setting Description
OFF Module’s SER1 to feature connector X56 (default)
ON Module’s SER1 to CAN connector X59

Table 50 JP7 - CAN Bus Termination/Filter


JP7
Pin Description 1 2

1-2 Enable 120 ohm CAN bus termination


3 4
2-3 Enable CAN bus filter

Note

Pins 42 and 44 of the feature connector alternatively supports CAN_TX and CAN_RX signals.

4.18 System Fan Header


The conga-TEVAL/COMe 3.0 provides a 3-pin fan connector X55 via the Super I/O controller. Use jumper:
•• JP5 to set the fan’s supply voltage level
•• JP6 to select the fan’s control source

Copyright © 2018 congatec AG TEVA2m11 47/56


Table 51 X55 - SYS Fan Pinout
X55
Pin Signal
1
1 GND
2
2 +VDD (12V/5V)
3
3 Sense

Table 52 JP5 - Fan Voltage Selection

Pin Description
JP5
1-2 12 V supply voltage for auxiliary fan (default)
2-3 5 V supply voltage for auxiliary fan 1 2 3

Table 53 JP6 - Fan Speed Control

Pin Description JP6


1-2 Fan speed control via Super I/O located on the conga-TEVAL/COMe 3.0 (default)
1 2 3
2-3 Fan speed control via the COM Express module
Open Full fan speed if the pins are left open

Connector Type

X55: Standard 2.54 mm, 3-pin fan housing

JP5, JP6: 2.54 mm grid jumper

Copyright © 2018 congatec AG TEVA2m11 48/56


4.19 CPU Fan Header
The conga-TEVAL/COMe 3.0 provides a 4-pin fan connector X60. Set the fan’s supply voltage level with jumper JP10.

Table 54 X60 - CPU Fan


X60
Pin Signal
1
1 GND
2
2 +VDD (12V/5V)
3
3 Sense 4
4 Control

Table 55 JP10 - CPU Fan Voltage Selection

Pin Configuration
JP10
1-2 12 V supply voltage (default)
1 2 3
2-3 5 V supply voltage

Connector Type

X60: Standard 2.54 mm, 4-pin fan housing

JP10: 2.54 mm grid jumper

4.20 Smart Battery Management Header


The conga-TEVAL/COMe 3.0 provides connector X61 for attaching smart battery module kits.

Table 56 X61 - SBM Pinout X61


Pin Signal
1 SUS_S5#
2 SUS_S3#
3 SUS_STAT#
4 I2C_DAT

Copyright © 2018 congatec AG TEVA2m11 49/56


5 I2C_CLK
6 BATLOW#
7 PWRBTN#
8 SYS_RST#
9 PWR_OK
10 GND

Connector Type

X61: 10-pin, 1.25 mm pitch picoBlade receptacle

4.21 Debug Pin Header


The conga-TEVAL/COMe 3.0 provides pin header X57 for measuring or debugging PCIE_WAKE# and CB_RESET# signals.

Table 57 X57 - Debug Pin Header


X57
Pin Signal
1 CB_RESET# 1 2

2 RAPID_SHUTDOWN 4
3
3 PCIE_WAKE
4 GND

Connector Type

X57: 4-pin header

4.22 Internal Use Only


The pin header X62 and DIP SW20 are for congatec internal use only.

Copyright © 2018 congatec AG TEVA2m11 50/56


4.23 Feature Connector
Table 58 X56 - Feature Connector Pinout Description

Pin Signal Description Pin Signal Description


1 +5V 5V supply with 750 mA fuse 2 5V_SB 5V standby supply with 750 mA fuse X56
3 SATA_LED_A SATA activity led (anode) 4 SATA_LED SATA activity led (cathode)

43
44
5 I2C_DAT General purpose I²C port data I/O line. 6 SMB_CK System Management Bus bidirectional clock line.

42

41
7 I2C_CK General purpose I²C port clock output. 8 SMB_DAT System Management Bus bidirectional data line.

40

39
9 Internal use 10 GPO0 General Purpose Output 0

38

37
11 Internal use 12 GPO1 General Purpose Output 1

36

35
13 PS_ON# Power supply on (active low). 14 GPO2 General Purpose Output 2

34

33
15 SUS_S3# Suspend to RAM state. Active low output. 16 GPO3 General Purpose Output 3

32

31
17 GND Power ground 18 GND Power Ground

30

29
19 THRMTRIP# Active low output indicating that the CPU 20 SMB_ALERT# System Management Bus Alert . It can be used to wake the system or

28

27
has entered thermal shutdown. generate an SMI# (System Management Interrupt)

26

25
21 GPI1 General Purpose Input 1 22 SUS_S4# Suspend to Disk state. Active low output.

24

23
23 SUS_STAT# Indicates imminent suspend operation; 24 GPI0 General Purpose Input 0

22

21
used to notify LPC devices.

20

19
25 GPI2 General Purpose Input 2 26 SUS_S5# Indicates systems is in soft off state.

18

17
27 WDT Watchdog Trigger 28 THRM# Input from off-module temp sensor indicating an over-temp situation.

16

15
29 GPI3 General Purpose Input 3 30 LID# Module input signal, generation a LID close or open event

14

13
31 BATLOW# Indicates that external battery is low. 32 WAKE1# General purpose wake up signal. May be used to implement wake-up

12

11
on PS2 keyboard or mouse activity.

10

9
33 TPM_PP TPM Physical presence pin 34 PEG_LANE_RV# PCI Express Graphics lane reversal input strap.

7
35 SLEEP# Sleep signal, to bring system to a 36 SYS_RESET# Reset Button Input. Active low input. System is held in hardware reset

5
predefined sleep state while this input is low

6
4

3
37 GND Power ground 38 GND Power ground

1
39 PWRBTN# Power button to bring system out of S5 40 PWR_OK Power OK from main power supply. A high value indicates that the
(soft off), active on rising edge. power is good.
41 SER0_TX COM module’s serial port 0 transmit line 42 SER1_TX COM module’s serial port 1 transmit line
43 SER0_RX COM module’s serial port 0 receive line 44 SER1_RX COM module’s serial port 1 receive line

Connector Type

X56: 44-pin, 2 row 2.54 mm grid female

Copyright © 2018 congatec AG TEVA2m11 51/56


5 Additional Features
5.1 Buttons
The conga-TEVAL/COMe 3.0 features the power, reset, LID and sleep buttons.

5.1.1 Power
When you press the power button SW16, it triggers the module’s PWRBTN# signal. The triggered event usually initiates a transition from one
power state to another (for example, from S5 to S0). However, the system’s behavior depends on the ACPI settings of the Operating System.
SW16

5.1.2 Reset
When you press the reset button SW16, it triggers the module’s SYS_RESET# signal. The triggered event usually invokes a system warm reset.
This behavior however depends on the configuration of the module.
SW17

5.1.3 LID
When you press the lid button SW18, it triggers the module’s LID# signal. The system’s behavior depends on the ACPI settings of the Operating
System.

SW18

Copyright © 2018 congatec AG TEVA2m11 52/56


5.1.4 Sleep
When you press the sleep button SW19, it triggers the module’s SLEEP# signal. The system’s behavior depends on the ACPI settings of the
Operating System.
SW19

5.2 Beeper
The beeper M25 provides audible error code (beep code) information during POST. The beeper is connected to pin B32 (SPKR signal) on the
COM Express™ module.

Use DIP SW9.1 to enable or disable the beeper.

Table 59 SW9.1 - Beeper Control SW9 M25


2

0N
Setting Description 1
ON Enable beeper (default)
OFF Disable beeper

5.3 Ground Test Points


The conga-TEVAL/COMe 3.0 provides 4 test points (M1-M4). These test points are connected to ground and they make it easier to connect
oscilloscope probes or multimeter lines or both to ground during measurements.

M1-M4

Copyright © 2018 congatec AG TEVA2m11 53/56


5.4 Debug Display
The conga-TEVAL/COMe 3.0 provides four 14-segment displays (D53-D56) for post code or debug information. Use the tables below to
configure the post code decoding process.

A list of the BIOS POST codes and associated POST test and initialization routines for congatec COM Express™ modules is available at
www.congatec.com.

Table 60 SW22 - POST Code Decoder

SW 1 SW 2 Configuration D53 D54 D55 D56


OFF OFF Off
ON OFF LPC
OFF ON I2C
ON ON SMB

Table 61 SW22 - POST Code LPC/I2C Address Decoder


SW22
SW 3 SW 4 Configuration

O
N
OFF OFF 80-84h (0xE0)

1
2
3
4
ON OFF 80-84 (0xE2)
OFF ON RSDV (0xE4)
ON ON RSVD (0xE6)

Copyright © 2018 congatec AG TEVA2m11 54/56


6 Mechanical Dimensions
293.37
288.29
209.55
163.83
153.68
66.68
6.35

243.84
237.49

D110

C110

A110
B110
189.3

165.1

159.3
151.3
148.3

D1

C1

A1
B1
72.3

33.02

10.16

Copyright © 2018 congatec AG TEVA2m11 55/56


7 Industry Specifications
Table 62 References

Specification Link
PICMG COM Express Module™ Base Specification
®
http://www.picmg.org/
Universal Serial Bus (USB) Specification http://www.usb.org/home
Serial ATA Specification http://www.serialata.org
High Definition Audio Specification http://www.intel.com/content/www/us/en/standards/high-definition-audio-specification.html
LVDS Owner’s Manual http://www.ti.com/lit/ml/snla187/snla187.pdf
Extended Display Identification Data Standard (EDID™) http://www.vesa.org
Enhanced Display Data Channel Specification (DDC) http://www.vesa.org
IEEE standard 802.3ab 1000BASE T Ethernet http://www.ieee.org/portal/site
Advanced Configuration and Power Interface Specification http://www.acpi.info

Copyright © 2018 congatec AG TEVA2m11 56/56

You might also like