The document outlines an assignment for a course on Electrical Engineering, focusing on various calculations related to three-phase circuits, including line and phase currents, power factors, and power consumption for different configurations (delta and star). It includes specific problems with provided answers for calculations involving resistances, inductances, and reactances in AC circuits. Additionally, it contains theoretical derivations related to voltage and current relationships in star and delta connected loads.

Uploaded by

mahvs.1311
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views

Assignment--Unit-2 electronics

The document outlines an assignment for a course on Electrical Engineering, focusing on various calculations related to three-phase circuits, including line and phase currents, power factors, and power consumption for different configurations (delta and star). It includes specific problems with provided answers for calculations involving resistances, inductances, and reactances in AC circuits. Additionally, it contains theoretical derivations related to voltage and current relationships in star and delta connected loads.

Uploaded by

mahvs.1311
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Subject: Fundamental of Electrical Engineering

Subject Code: BEE-101


Semester: I
Section: A5-IT-2
Faculty Name: Mr. Nirmal Kumar Agarwal

Submission Date: 03-01-2024

UNIT-2

Assignment-3

1. Three coils each of 5 Ω resistance and 6 Ω inductive reactance are connected in closed
delta and supplied from a three phase 440 volt. Calculate the line and phase currents,
power factor of the system and intake power in watts.
Write down the expressions for the current flowing when this voltage is applied across:
[ANS: iL = 97.58 A; iph = 56.33 A; p.f. = 0.64 (lagging); P=47.61 KW]

2. A balanced star-connected load with (6+j8) Ω per phase is connected to a three-phase 440
Volts supply. Find the line current, power factor, active power, reactive power and
apparent power. [ANS: 25.404 A; 0.6 (lagging); 11.616 KW; 15.488 KVAR; 19.360 KVA]

3. Three coils each having a resistance of 10 Ω and inductance of 0.02 H are connected in (i)
star and (ii) delta to a three-phase 50 Hz ac supply, the line voltage being 500 Volts.
Calculate for each case the line current and the total power taken from the supply.
[ANS: (a) Star: 24.46 A; 17.94 KW and
(b) Delta: 73.39 A; 53.83 KW]

4. A choke coil of 10 Ω resistance and 0.1 H inductance is connected in series with a


capacitor of 200 µF capacitance across a supply voltage of 230 volts, 50 Hz ac supply.
Find the following w.r.t. the resonant circuit.
[ANS: 35.59 Hz; 22.36 Ω; 10 Ω; 744.28 V; 514.28 V; 27.63 Hz; 43.55 Hz; 2.24; 5.29 KW; 1]
i. Neat and clean circuit diagram indicating all the relevant parameters.
ii. At what frequency will be circuit resonate.
iii. Value of reactance at resonance condition.
iv. Impedance of the coil at resonance condition.
v. Voltage across the coil and voltage across the capacitor.
vi. Half power frequencies f1 and f2.
vii. Q factor of the circuit.
C-20/1, Sector-62, Noida-201301
Tel: 0120-2400114, 2400115, Fax: 0120-2400097, E-mail: [email protected]
viii. Power and power factor.

5. Three coils, each having a resistance of 20 Ω and an inductive reactance of 15 Ω are


connected in star to a 400 Volt, 3-phase 50 Hz ac supply. Calculate the line current, power
factor and power supplied. [ANS: 9.24 A; p.f. 0.8 (lagging); 5121 Watt]

6. Three similar coils connected in star, take a total power of 1.5 Kw at a p.f. of 0.2 lagging
from a 3-phase, 400 V, 50 Hz ac supply. Calculate the resistance and inductance of each
coil. [ANS: 4.27 Ω; 0.0665 H]

7. Three similar coils each having a resistance of 5 Ω and an inductance of 0.02 H are
connected in delta to a 440 V, 3-phase 50 Hz ac supply. Calculate the line current and total
power absorbed. [ANS: 94.90 A; 44.98 KW]

8. Three identical coils connected in delt across 400 V, 50 Hz ac supply, take a line current of
17.32 A at a p.f. of 0.8 lagging. Calculate: [ANS: 10 A; 32 Ω; 76.3943 mH; 3200 watt]
a. The phase currents
b. The resistance and inductance of each coil
c. The power drawn by each coil

9. Derive the relationship of voltage and current in star connected load.


10. Derive the relationship of voltage and current in delta connected load.

C-20/1, Sector-62, Noida-201301


Tel: 0120-2400114, 2400115, Fax: 0120-2400097, E-mail: [email protected]