0% found this document useful (0 votes)
136 views2 pages

MCX06C Instrukcja

The MCX06C electronic controller by Danfoss Electronics features multiple input and output options, including analog and digital interfaces, and is designed for integration into Class I and II appliances. It complies with various EU standards and has specific operational and installation warnings to ensure safety and functionality. The device is programmable and supports communication via CANbus and Modbus RS485, making it versatile for refrigeration and air conditioning applications.

Uploaded by

Saravanavel C
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
136 views2 pages

MCX06C Instrukcja

The MCX06C electronic controller by Danfoss Electronics features multiple input and output options, including analog and digital interfaces, and is designed for integration into Class I and II appliances. It complies with various EU standards and has specific operational and installation warnings to ensure safety and functionality. The device is programmable and supports communication via CANbus and Modbus RS485, making it versatile for refrigeration and air conditioning applications.

Uploaded by

Saravanavel C
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

MAKING MODERN LIVING POSSIBLE

GENERAL FEATURES GENERAL FEATURES AND WARNINGS

PLASTIC HOUSING FEATURES


MCX06C - Self extinguishing V0 according to IEC 60695-11-10 and glowing/hot wire test at 960°C
according to IEC 60695-2-12
ANALOG INPUTS - Ball test: 125°C according to IEC 60730-1. Leakage current: ≥ 250V according to IEC 60112
Danfoss Electronics spa NTC, 0/1V, 0/5V 2
OTHER FEATURES
Universal (NTC, Pt1000, 0/1V, 0/5V, 0/10V, ON/OFF, 0/20mA, 4/20mA) selectable via software 2 - Operating conditions CE: -20T60 / UL: 0T55, 90% RH non-condensing
Total number 4 - Storage conditions: -30T80, 90% RH non-condensing
- To be integrated in Class I and/or II appliances
DIGITAL INPUTS - Index of protection: IP64 ~ NEMA3R only on the front cover
Voltage-free contact 6 - Period of electric stress across insulating parts: long
Total number 6 - Suitable for using in a normal pollution environment
- Category of resistance to heat and fire: D
ANALOG OUTPUTS - Immunity against voltage surges: category I
0/10Vdc, PWM, PPM selectable via software 1 - Software class and structure: class A
PWM, PPM selectable via software 1 CE COMPLIANCE
Total number 2 This product is designed to comply with the following EU standards:
- Low voltage guideline: 73/23/EEC
DIGITAL OUTPUTS - Electromagnetic compatibility EMC: 89/336/EEC and with the follwing norms:
SPST relay 5A (normally open contacts) 6 - EN61000-6-1, EN61000-6-3 (immunity for residential, commercial and ligth-industrial environments)
Total number 6 - EN61000-6-2, EN61000-6-4 (immunity and emission standard for industrial environments)
- EN60730 (Automatic electrical controls for household and similar use)
OTHERS
UL APPROVAL
Insulated power supply 20/60Vdc - 24Vac •
UL file: E31024
Connection for programming key •
Connection for remote display and keyboard • GENERAL WARNINGS
- Every use that is not described in this manual is considered incorrect and is not authorised by the
Buzzer manufacturer
CANbus • - Verify that the installation and operating conditions of the device respect the ones specified in the
RTC clock • manual, specially concerning the supply voltage and environmental conditions
Modbus RS485 serial interface • - This device contains live electrical components therefore all the service and maintenance operations
must be performed by qualified personnel
Dimensions (mm) 33x75
- The device can’t be used as a safety device
Mounting Panel - Liability for injury or damage caused by the incorrect use of the device lies solely with the user
INSTALLATION WARNINGS
MCX06C electronic controller - The installation must be executed according the local standards and legislations of the country
- Always operate on the electrical connections with the device disconnected from the main power supply
MCX06C is an electronic controller that holds all the - Before carrying out any maintenance operations on the device, disconnect all the electrical connections
- For safety reasons the appliance must be fitted inside an electrical panel with no live parts accessible
typical functionalities of MCX controllers in the 32x74 - Don’t expose the device to continuous water sprays or to relative humidity greater than 90%.
mm standard size: programmability, connection to Avoid exposure to corrosive or pollutant gases, natural elements, environments where explosives or
mixes of flammable gases are present, dust, strong vibrations or chock, large and rapid fluctuations in
the CANbus local network, Modbus RS485 serial ambient temperature that in combination with high humidity can condensate, strong magnetic and/or
communication interface radio interference (e.g. transmitting antennae)
- When connecting loads beware of the maximum current for each relay and connector
- Use cable ends suitable for the corresponding connectors. After tightening the screws of connectors,
slightly tug the cables to check their tightness
- Use appropriate data communication cables. Refer to the Fieldbus Installation Guide for the kind of cable to be
REFRIGERATION & used and setup recommendations
AIR CONDITIONING DIVISION - Reduce the path of the probe and digital inputs cables as much as possible, and avoid spiral paths
enclosing power devices. Separate from inductive loads and power cables to avoid possible
MYK connection Modbus RS485 electromagnetic noises
- Avoid touching or nearly touching the electronic components fitted on the board to avoid electrostatic

485 discharges

TECHNICAL SPECIFICATIONS

Danfoss Electronics spa POWER SUPPLY


- 20/60Vdc and 24Vac ±15% 50/60Hz. Maximum power consumption: 6W, 9VA
Viale Venezia, 59 - Insulation between power supply and the extra-low voltage: functional
31020 San Vendemiano
(TV) Italy I/O TYPE NUMBER SPECIFICATIONS I/O TYPE NUMBER SPECIFICATIONS
Digital Relay 6 Insulation between relays: functional (common lines internally connected) Analog NTC, 0/1V, 0/5V 2 AI1, AI2
Tel: +39 0438 336611 outputs Insulation between relays and the extra-low voltage parts: reinforced inputs Analog inputs selectable via software between:
Fax: +39 0438 336699 Total current load limit: 6A - NTC temperature probes, default: 10kΩ at 25°C
- pressure transducers with 0/5V output
C1-NO1, C2-NO2, C3-NO3, C4-NO4, C5-NO5, C6-NO6
[email protected] Normally open contact relays:
Universal 2 AI3, AI4
www.danfosselectronics.com - characteristics of each relay: Universal analog inputs selectable via software between:
4A 30Vdc / 250Vac for resistive load - 100.000 cycles - ON/OFF (current: 20mA)
0,7A 250Vac for inductive load - 100.000 cycles with cos(phi) = 0,5 - 0/1V, 0/5V, 0/10V
UL: 240Vac - 1A resistive - 1.0FLA - 6.0LRA - 96VA pilot duty 30.000 cycles - 0/20mA, 4/20mA
- NTC (10kΩ at 25°C)
Digital Voltage free 6 DI1, DI2, DI3, DI4, DI5, DI6 - Pt10000
inputs contact Current consumption: 5mA 12V+ power supply 12Vdc, 50mA max for 4/20mA transmitter (total on all outputs)
Analog 0/10V, PWM, PPM 1 AO1 5V+ power supply 5Vdc, 80mA max for 0/5V transmitter (total on all outputs)
outputs Analog outputs selectable via software between:
- pulsing output, synchronous with the line, at modulation of impulse position (PPM)
or modulation of impulse width (PWM):
open circuit voltage: 6.8V
minimum load: 1kΩ
- pulsing output, at modulation of impulse position (PPM) with range from 100Hz to 500Hz:
open circuit voltage: 6.8V
minimum load: 1kΩ
- 0/10Vdc non optoinsulated output, referred to the ground:
10mA maximum loads
PWM, PPM 1 AO2
Analog outputs selectable via software between:
- pulsing output, synchronous with the line, at modulation of impulse position (PPM)
or modulation of impulse width (PWM):
open circuit voltage: 6.8V
minimum load: 1kΩ
- pulsing output, at modulation of impulse position (PPM) with range from 100Hz to 500Hz:
open circuit voltage: 6.8V
minimum load: 1kΩ
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right
to alter its products without notice. This also applies to products already on order provided that such alternations can be made without
subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respecitve
companies. Danfoss and Danfoss logotype are trademarks of Danfoss A/S. All rights reserved

RI8MP202 - MCX06C instruction sheet - P.N. 3106000130 - 15-310600013A


Produced by Danfoss Electronics spa Graphic Department, 03-2009
CONNECTION DIAGRAM CONNECTIONS

- Input/output connector
18 way Molex Microfit type (43025-1800) crimping contact type:
Molex: (43030-0001) section cable AWG20-24 (0.52-0.20mm²)
Molex: (43030-0004) section cable AWG26-30 (0.13-0.05mm²)
Instrument for the Molex crimp code 69008-0982 (20-24 AWG)
Instrument for the Molex crimp code 69008-0983 (26-30 AWG)
Analog
output

local network - CAN connector


NTC

0/5 V
4 way Molex Wire-to-board type (87369-0400) crimping contact type:
NTC
Pt1000
(80 mA max)

UNIVERSAL
ON/OFF Molex: (50212-8000) section cable AWG24-30 (0.20-0.05mm²)
to the AI

supply
board
Power
TTL Serial Comm.
DI 1

DI 3

DI 5

0/1 V
Instrument for the Molex crimp code 63811-1200

CANbus
0/5 V (if expected)
0/10 V
PWM

- CAN/485 connector
PPM

0/10 V
0/20 mA
4/20 mA * 8 way Molex Wire-to-board type (87369-0800) crimping contact type:
Molex: (50212-8000) section cable AWG24-30 (0.20-0.05mm²)
Instrument for the Molex crimp code 63811-1200

CAN

CAN485

TX/D+
INPUT/OUTPUT

COM

COM

GND

GND

ID
VCC
DI 1
A0 1

CAN

CAN
AI 1

CANH
DI 3

CANH
CANL
AI 3

CANL
- Power supply connector
DI 5

DIR
5V+

RX/D-
R1 20
2 way Molex KK type (09-50-8021) crimping contact type:
Molex: (08-50-0105) section cable AWG18-24 (0.82-0.20mm²)
Molex: (08-50-0107) section cable AWG22-26 (0.32-0.13mm²)
Instrument for the Molex crimp code 69008-0953
COM

12V+

COM
A0 2

AI 2
DI 4

AI 4
DI 2

DI 6

- Digital output 1-6 connector

RS485 (Modbus)
12 way Molex Minifit Jr. type (39-01-2125) crimping contact type:

(if expected)
PWM
PPM

0/5 V
NTC

NTC Molex: (39-00-0077) section cable AWG16 (1.30mm²)


Pt1000
Molex: (39-00-0038) section cable AWG18-24 (0.82-0.20mm²)
UNIVERSAL
(50 mA max)

ON/OFF
to the AI

0/1 V Molex: (39-00-0046) section cable AWG22-28 (0.32-0.08mm²)


regulator

MCX06C
DI 2

DI 4

DI 6
speed

0/5 V Instrument for the Molex crimp code 69008-0724


0/10 V
0/20 mA
4/20 mA

L N

N0 1

N0 2

N0 3

N0 4

N0 5

N0 6

DIGITAL OUTPUT
POWER SUPPLY

N1
L1

C1

C2

C3

C4

C5

C6
**
5A

5A

5A

5A

5A

5A

L L
24 Vac
N N

*NOTE: connection has to be made on the first and last local network units, make the connection as close as possible to the connector
**NOTE: C1, C2, C3, C4, C5, C6 internally connected between themselves

MAKING MODERN LIVING POSSIBLE

DIMENSIONS USER INTERFACE

Danfoss Electronics spa


LED display LED DISPLAY
- type: LED display with two groups of digits and 18 icons
- colour of digits: green
- colour of the allarm/warning icons: red
- color of the other icons: yellow/amber
- the meaning of the icons and digits is settled by the application software
- dimensions: 45x17mm

29
28
33

75 75 71
Drilling template
minimal thickness of panel 0.8mm
84 13

KEYBOARD
- number of keys: 4
- keys function is settled by the application software

MCX06C electronic controller

REFRIGERATION & PRODUCT PART NUMBERS


AIR CONDITIONING DIVISION
MYK connection Modbus RS485
CODE DESCRIPTION
485 080G0065
080G0066
MCX06C, 24V, LED, S
MCX06C, 24V, LED, RS485, RTC, S