Switching Power Supply - en
Switching Power Supply - en
▇ Summary
1. Switching power supply is a high frequency switch mode power electronics products, often used
as a power supply device, usual power conversion methods have: AC-DC, DC-DC, DC-AC etc.
2. Switching power supply has features of high efficiency, small size, and high adaptability, because
of its operating principal.
S - 120 - 12
Output groups quantity Output power (W) Output voltage V
S: Single group
D: Double groups
T: Triple groups
Q: Four groups
om
▇Selection instructions
1. Input voltage: The input voltage has: 110VAC, 220VAC, 380VAC, need be consistent to the supply
voltage.
.c
2. Output voltage: The output voltage has: 3.5V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V ...... (Within
3.0V-110V range), 380VAC, need match the load's rated voltage.
ai
3. Output current: confirmed by the current or the average current value measured by multimeter. If it
is high ambient temperature, bad air flow, inductive load, please add 20 to 30% of the current
balance.
l
ng
4. Output power: decided by the load rated power. If you don't know the power, can calculated by
load's rated current and rated voltage (Current * Voltage = Power), the switching power supply's
power should be 15 to 30% greater than the actual used power and peak power.
.fi
5. Output DC group: Usual it has four types: S- single group, D-dual, T- three groups, Q- four groups,
decided by the load.
w
6. Switching power supply has over / undervoltage, overcurrent, overheating protection and cooling
fan protection. Please choose according to actual usage, in order to enhance the systems
w
▇ Use description
1. 1.1 Connect the live line and neutral line to L, N.
1.2 The DC output's positive is marked as "+ V", negative is marked as "- V, COM".
1.3 Multiple DC output voltage are marked: "+ V1", "+ V2", "+ V3", "+ V4", "- V1", "- V2", "- V3", "-
V4" etc or marked voltage directly. The positive and negative's common interfaces is "COM".
om
3. According to the input AC voltage, pull the switch to 115V or 230V, so as not to damage the
switching power supply.
4. When the power network environment is poor, please consider giving measures to enhance the
stability and reliability of the using switching power supply.
.c
5. When the supply voltage fluctuate big and often undervoltage, overvoltage, consider installing
power enough voltage regulator or Over/Under Voltage Protector before providing power to power
ai
equipment.
6. When the power grid has using large electrical equipment, please consider installing matched AC
l
filter before providing power to power equipment.
ng
7. Can full load use within the allowed ambient humidity range, when the ambient humidity exceeds
the upper limit, should reduce output power based on the power output curve. For example, if the
switching power supply's operating temperature is -10 ~ 45 °C, when the ambient humidity is 70 °
.fi
C, the output power should not exceed 50% rated power, when the ambient temperature is below
-10 °C, the power supply may not start or not normal output.
w
▇ Warranty
w
1. Warranty: 1 year.
w
2. If the used environment is beyond the specified range or the exist man-made damage factors, will
not have free maintenance service.
3. If self overhaul or replace product, will not have free maintenance service.