Firmware Update Tools For D195/D295
Firmware Update Tools For D195/D295
Contents
1. Objective ........................................................................................................................................ 3
2. Operation ....................................................................................................................................... 3
2.1. Basics........................................................................................................................................... 3
2.2. Invoking the update tool................................................................................................................ 3
2.2.1. Via B&R Software Manager (SWman) ....................................................................................... 3
2.2.2. Standalone mode ...................................................................................................................... 3
2.3. The update process...................................................................................................................... 4
3. Troubleshooting ............................................................................................................................ 4
4. Contact information....................................................................................................................... 6
Documentation 2
T. Hermann Documentation 2014-01-15
P-DDE Version 1.0
1. Objective
The D195prog and D295prog tools serve for loading the ATL and RQM firmware into the “Qualisizer II”
(D195) and “Qualisizer III” (D295) signal processor units in Rieter autoleveler draw frames. They can
also be used for updating the D195/D295 firmware in these machines during field service.
2. Operation
2.1. Basics
The D195prog and D295prog tools (currently) do not use a GUI. Instead, they are controlled via
parameters passed to the program via command-line parameters. There are several possibilities to do
this, as outlined in the following sections.
Since D195 and D295 use different hardware, the update process will fail if the wrong tool for the device
at hand is used. Also, a firmware file intended for D195 will not work on a D295, and vice versa.
After installation of the package, a corresponding item will appear in the “D” menu of the SWman
window. The update process is conveniently started by choosing the proper selection from there.
NOTE: Of course, before attempting firmware download to the D195/295, the RS232 null-modem cable
must first be detached from the A1 panel, if still connected there, and plugged into connector X1 on the
D195/295!
Documentation 3
T. Hermann Documentation 2014-01-15
P-DDE Version 1.0
The example screenshot above was taken during a successful update of a D195 ATL processor. Note
the “SUCCESS” message at the bottom. Should any problem occur, the process will usually terminate
with an “ERROR” message instead. Refer to the Troubleshooting section for help in this case.
3. Troubleshooting
3.1. Possible problems and their causes
This section gives an overview over a selection of possible problems.
Both these cases should not occur when using the procedures outlined in section 2.2 on a system
with the standard software and hardware configuration.
Make sure that the D195/D295 to be updated is powered up (green LED A1 is on) and properly
connected to the COM1 port. In particular:
The LEDs on the front panel of the D195/D295 must react when the update process is started.
Documentation 4
T. Hermann Documentation 2014-01-15
P-DDE Version 1.0
These errors most likely point to a problem with the data connection between the COM port and the
D195/D295. The null-modem cable should not be longer than 2 m. Check for bad and/or intermittent
connections, then retry the update process. If this does not help, contact Rieter service.
The internal Flash memory on the D195/D295 appears to be defective. Retry the update process. If
the problem persists, the D195/D295 will need to be replaced.
The Windows OS has reported an error during a system function call. Retry the update process, and
if this does not help, please use the steps outlined in section 3.2 to notify the developers.
The text within the console window should now appear highlighted in white:
Documentation 5
T. Hermann Documentation 2014-01-15
P-DDE Version 1.0
Right-click somewhere into the console window. The white highlighting should disappear. Now, the text
has been copied into the Windows clipboard and can easily be pasted into an E-mail or CORN report.
================================================
D295 Firmware Update Tool (Command Line Version)
Version 1.12 Jan 10 2014 T. Hermann / P-DDE
(c) 2013-2014 Rieter Ingolstadt GmbH
This tool is intended for internal use only!
================================================
4. Contact information
Mohammed
Mr. Tobias Habibur
Hermann, Rahman
Team P-DDE
System engineer
Rieter Ingolstadt GmbH, Germany
Hardware Software Troubleshoter
E-Mail: [email protected]
Email : [email protected]
Documentation 6