0% found this document useful (0 votes)
14 views5 pages

E5 Pro

The FLIR E5 Pro is an infrared camera with a resolution of 160 × 120 pixels and a thermal sensitivity of <0.07°C. It features a 3.5-inch color LCD display, various image modes, and a measurement range of -20 to 400°C with specific accuracy. The camera is designed for durability, with an operating temperature range of -15°C to +50°C and includes a rechargeable lithium-ion battery.

Uploaded by

DavenderSingh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views5 pages

E5 Pro

The FLIR E5 Pro is an infrared camera with a resolution of 160 × 120 pixels and a thermal sensitivity of <0.07°C. It features a 3.5-inch color LCD display, various image modes, and a measurement range of -20 to 400°C with specific accuracy. The camera is designed for durability, with an operating temperature range of -15°C to +50°C and includes a rechargeable lithium-ion battery.

Uploaded by

DavenderSingh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

FLIR E5 Pro

P/N: 13301-0101
Copyright
© 2023, FLIR Systems, Inc.
All rights reserved worldwide. Names and marks
appearing herein are either registered trademarks
or trademarks of FLIR Systems and/or its
subsidiaries. All other trademarks, trade names or
company names referenced herein are used for
identification only and are the property of their
respective owners.
Document identity
Publ. No.: 13301-0101
Commit: 93758
Language: en-US
Modified: 2023-10-23
Formatted: 2023-10-23
Website
http://www.flir.com
Customer support
http://support.flir.com
Disclaimer
Specifications subject to change without further Imaging and optical data
notice. Camera models and accessories subject IR resolution 160 × 120 pixels
to regional market considerations. License
procedures may apply. Products described herein Thermal sensitivity/NETD <0.07°C (0.13°F) / <60 mK at 30°C (86°F)
may be subject to US Export Regulations. Please
refer to [email protected] with any Field of view (FOV) 33° × 25
questions. Minimum focus distance 0.36 m (1.18 ft.)

Spatial resolution (IFOV) 3.7 mrad


F-number 1.4
Image frequency 9 Hz

Focus Fixed focus

Detector data
Detector type Focal plane array (FPA), uncooled
microbolometer
Spectral range 7.5–13 µm

User interface
Display 3.5 in. 640 × 480 color LCD
Touch screen Capacitive touch

Text Text annotation on image using onscreen


keyboard
Flashlight Manually activated bright LED

Image presentation
Display 3.5 in. 640 × 480 color LCD
Image adjustment Automatic/Manual

Image presentation modes

Image modes Thermal MSX, Thermal, Picture-in-Picture, Digital


camera.
Multi Spectral Dynamic Imaging (MSX) IR image enhanced with visible camera detail

Picture in Picture IR area on visual image

1 (5) www.flir.com
FLIR E5 Pro

P/N: 13301-0101 Measurement


© 2023, FLIR Systems, Inc. Camera temperature range
• –20 to 200°C (–4 to 392°F)
#13301-0101; r. 93758; en-US • 10 to 400°C (50 to 752°F)

Object temperature range and accuracy (for


• Range –20 to 200°C (–4 to 392°F):
ambient temp. 10 to 35°C (50 to 95°F) and object
temp. above 0°C (32°F)) ◦ 0 to 100°C (32 to 212°F): ±2°C (±3.6°F)
◦ 100 to 200°C (212 to 392°F): ±2%
• Range 10 to 400°C (50 to 752°F):
◦ 10 to 100°C (50 to 212°F): ±4°C (±7.2°F)
◦ 100 to 400°C (212 to 752°F): ±4%

Measurement analysis

Spotmeter Center spot, box with min./max.


Isotherm Above alarm, Below alarm
Delta T Yes, NFPA 70B compliant
Emissivity correction Variable from 0.1 to 1.0
Emissivity table Emissivity table of predefined materials

Measurements correction Emissivity, matt/semi-matt/semi-gloss + custom


value, reflected apparent temperature,
atmospheric compensation

Set-up

Color palettes Iron, White hot, Black hot, Rainbow, Arctic, Lava,
Rainbow HC
Set-up commands Local adaptation of units, language, date and time
formats

Storage of images

File formats Standard JPEG, 14-bit measurement data


included
Storage media Internal memory and onboard FLIR Ignite cloud
connectivity (with Wi-Fi)

Digital camera

Digital camera, resolution 5 MP

Digital camera, FOV 52.7°

Video streaming

Radiometric IR video streaming Yes, USB connection

Non-radiometric video streaming Yes; MSX, Thermal, Visual, Picture in Picture.


USB Video Class colorized uncompressed with
overlay 9 Hz.

Data communication interfaces


Interfaces USB-C: Data transfer to and from PC and Mac
device
Wi-Fi Infrastructure (network)

Radio
Wi-Fi
• Standard: 802.11 a/b/g/n
• Frequency range:
◦ 2400–2473 MHz
◦ 5150–5250 MHz
• Max. output power: 16 dBm

2 (5) www.flir.com
FLIR E5 Pro

P/N: 13301-0101 Power system


© 2023, FLIR Systems, Inc. Battery type Rechargeable Lithium-ion battery
#13301-0101; r. 93758; en-US
Battery voltage 3.65 V

Battery operating time 4 hours at +25°C (+77°F) ambient temperature


and typical use

Charging system Battery is charged inside the camera or in specific


charger.

Charging time 2 hours in charger. 4 hours to 90% capacity in


camera.
Power management Automatic shut-down

AC operation AC adapter, 100–240 VAC input, 5 VDC output to


camera
Battery documents For documents like MSDS and UN38.3 test
reports/summaries, see:
https://support.flir.com/resources/msds

Environmental data
Operating temperature range –15°C to +50°C (+5°F to +122°F)

Storage temperature range –40°C to +70°C (–40°F to +158°F)

Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity

EMC
• EN 301 489-1
• EN 301 489-17
• EN 61000-6-2 (Immunity)
• EN 61000-6-3
• FCC 47 CFR Part 15 Class B (Emission)
Radio spectrum
• ETSI EN 300 328
• ETSI EN 301 893
• FCC 47 CFR Part 15 C, E
• RSS-247 Issue 2
Hazardous substances
• WEEE 2012/19/EU
• RoHs 2011/65/EU
Shock 25 g (IEC 60068-2-27)

Vibration 2 g (IEC 60068-2-6)

Safety Camera:
• IEC/EN 62368-1
Power supply:
• IEC/EN 62368-1
• UL/J/(AS/NZS) 62368-1
• GB 4943
Declaration of conformity See: https://support.flir.com/resources/DoC

Physical data

Camera weight, incl. battery 0.590 kg (1.3 lb.)

Camera size (L × W × H) 244 × 95 × 140 mm (9.6 × 3.7 × 5.5 in.)

Color Black

3 (5) www.flir.com
FLIR E5 Pro

P/N: 13301-0101 Shipping information


© 2023, FLIR Systems, Inc. Packaging, type Cardboard box
#13301-0101; r. 93758; en-US
List of contents
• Infrared camera with battery
• Power supply
• USB cable
• FLIR Thermal Studio Starter
• Printed documentation
• Hard transport case
Packaging, weight 3.13 kg (6.9 lb.)

Packaging, size 385 × 165 × 315 mm (15.2 × 6.5 × 12.4 in.)

EAN-13 4743254006454
UPC-12 845188029142
Country of origin Estonia

Supplies & accessories:


• T198528; Hard transport case FLIR Ex series
• T198531; Battery charger incl power supply
• T198532; Car charger
• T198534; Power supply USB-micro
• T198529; Pouch FLIR Ex and ix series
• T198533; USB cable Std A <-> Micro B
• T199362ACC; Battery Li-ion 3.6 V, 2.6 Ah, 9.4 Wh
• T911630ACC; Power supply for camera, 15 W/3 A
• T911689ACC; Pouch for FLIR E-series
• T911093; Tool belt
• T300083; FLIR Thermal Studio Pro, Perpetual license
• T300341; FLIR Thermal Studio Standard, 1 Year Subscription
• T300258; FLIR Thermal Studio Standard, Perpetual license
• T199233; FLIR Atlas SDK for .NET

4 (5) www.flir.com
Denna handling får ej delges annan, kopieras i This document must not be communicated or
sin helhet eller delar utan vårt medgivande . copied completely or in part, without our permission.
Överträdelse härav beivras med stöd av gällande lag. Any infringement will lead to legal proceedings.
FLIR SYSTEMS AB FLIR SYSTEMS AB
B
A

H
E

F
D

G
1

1
2

2
IR camera axis
3

3
Visual camera axis

0,57in
14,5mm
7,42in 2,22in
188,4mm 56,5mm
4

4
3,05in
109

77,5mm
,

Weight: 590g
2in

Center of gravity
4,3 6mm

USB-C Connector
1,94in
49,2mm
3,06in
77,8mm
5

5
5,51in
139,8mm

1,04in
26,5mm

60,
7
9in
2,3 mm
250
,
9,8 4mm
6in
6

6
7

9,64in
244,8mm
8

Modified by
1,7in

3,87in

Denomination
98,4mm
43,2mm

T. HÄLLGREN
9

Basic Dimensions - Ex
Approved by

This document does not contain any export-controlled information.


Modified

Size

Scale
A2
1:2
2023-02-15

Drawing No
10

T131965
Rev
Sheet

A
1(1)
D

F
B
A

E
C

You might also like