You are on page 1/ 1

LEGEND:

1 50 MM PVC PIPE
2 50 MM 90ª PVC ELBOW
3 PACIFIER
4 P TRAP 25 MMØ WATER MAIN
25 MMØ GATE VALVE 25 MMØ CHECK VALVE
5 STRAINER
FINISHED FLOOR 32 MMØ CWL
90O ELBOW NGL
TO SUPPLY
GRAVEL BED
KITCHEN SINK DETAIL WATER METER DETAIL
SCALE: NTS
SCALE: NTS
PLUMBING NOTES:
1. ALL MATERIALS, FIXTURES & EQUIPMENT TO BE USED IN THE PLUMBING INSTALLATION SHALL BE NEW, OF THE APPROVED TYPE & SIZE
AS TO ITS INTENDED USAGE.
2. ALL INSTALLATION SHALL BE IN CONFORMANCE WITH THE PLUMBING CODE OF THE PHILS. ITS RULES & REG.
3. DRAINAGE PIPING SHALL BE PROVIDED WITH APPROVED INLET FITTINGS FOR FIXTURE CONNECTIONS, CORRECTLY LOCATED ACCORDING
TO THE SIZE & TYPE OF FIXTURE PROPOSED TO BE CONNECTED.
FEEDER
4. CHANGE IN DIRECTION OF DRAINAGE PIPING SHALL BE MADE WITH APPROPRIATE USE OF APPROVED FITTINGS & SHALL BE OF THE
FOR WC 1 BEND, 1 BEND, 1 BEND OR OTHER APPROVED FITTINGS OR EQUIVALENT SWEEP.
ANGLES REPRESENTED BY A 16 8 6
5. PROVIDE CLEANOUT FOR EACH CHANGE IN DIRECTION IF THE TOTAL AGGREGATE CHANGE EXCEEDS 135°.
6. EACH CLEANOUT SHALL BE INSTALLED SO THAT IT OPENS IN A DIRECTION OPPOSITE TO THE FLOW OF SOIL OR WASTE OR AT RIGHT
100 MM PVC ANGLES THERETO. ADDITIONAL CLEANOUTS SHALL BE INSTALLED AT INTERVALS NOT TO EXCED 100 FT (30.5 m) IN STRAIGHT RUNS.
SANITARY/SOIL PIPE
SLOPED @ 2% 7. HORIZONTAL DRAINAGE PIPING SHALL RUN IN PRACTICAL ALIGNMENT & A UNIFORM SLOPE OF NOT LESS THAN 41 OF AN INCH / FT. (20.8
mm/mt) OR 2% TOWARD THE POINT OF DISPOSAL.
8. UNLESS PROHIBITED BY STRUCTURAL CONDITIONS, EACH VENT SHALL RISE VERTICALLY TO A POINT NOT LESS THAN 6" (152.4 mm) ABOVE
THE FLOOD LEVEL RIM OF THE FIXTURE SERVED BEFORE OFFSETTING HORIZONTALLY.
9. EACH VENT PIPE OR STACK SHALL EXTEND THROUGH ITS FLASHING & SHALL TERMINATE VERTICALLY NOT LESS THAN 6" (152.4 mm)
ABOVE THE ROOF & ONE FOOT (0.30 m.) FROM ANY VERTICAL SURFACE.
WATER CLOSET DETAIL 10. PIPING SHALL BE LAID ON A FIRM BED THROUGHOUT ITS ENTIRE LENGHT. IF ANY SUCH PIPING IS LAID IN MADE OR FILLED GROUND, IT
SCALE: NTS
SHALL BE LAID ON A BED OF APPROVED MATERIALS & SHALL BE ADEQUATELY SUPPORTED.
CIVIL ENGINEER: DESIGNED BY: REVISIONS: DATE: PROJECT TITLE: OWNER: R.A. 9266 SHEET CONTENTS: SHEET NO:
JOHN BENEDICK LAGASCA Drawings and specifications duly signed, stamped or sealed as instruments of service are the
PROPOSED 4- BEDROOM properties and documents of the architect whether the object for which they are made is executed or not.
CAD BY: ENGR. MARK JOHN MACANDOG
16
JOHN BENEDICK LAGASCA JOHN BENEDICK LAGASCA BUNGALOW RESIDENTIAL BUILDING It shall be unlawful for any person, without the written consent of the architect or author of said
documents to duplicate or to make copies of said documents for use in the repetition of and for other
CHECKED BY: PROJECT LOCATION: ADDRESS: PULONG BULI, STO DOMINGO,
projects or building whether executed partly or in whole.
AS SHOWN
PRC REG NO: PTR NO: NUEVA ECIJA PRESIDENTIAL DECREE NO. 49
DATE ISSUED: PULONG BULI, STO DOMINGO, "Protection of Intellectual Property" November 14, 1972
VALIDITY: DATE: Works of art, architecture, models and designs are creative work and considered as part of the
TIN: PLACED ISSUED: JANUARY 15, 2025 NUEVA ECIJA DATE APPROVED: intellectual property of the author duly protected under P.D. 49.