Epsilon Extensometer Catalog
Epsilon Extensometer Catalog
Extensometer Catalog
Version 110.16
TABLE OF CONTENTS
ii
OUR COMPANY
Strain measurement for materials testing is our sole business
at Epsilon.
At Epsilon, we specialize in strain measurement for materials testing. For three decades we
have dedicated our efforts to developing top-quality extensometers and calibrators. Located
in scenic Jackson, Wyoming, our state-of-the-art facility is where we design and manufacture
extensometers for testing all kinds of materials: metals, composites, plastics, ceramics,
elastomers, geomaterials, and biomaterials. From fine wire to large rebar, there are models for
tension, compression, bend, shear, torsion, bi-axial, and fracture mechanics testing. Most of our
extensometers are capable of cyclic fatigue testing over a range of frequencies and operating in
strain control.
• Broad Product Line: We offer 36 different extensometer models with thousands of variations,
providing an optimized solution for almost any test method and ensuring the perfect fit for your specific
needs.
• Reputation for Quality: Quality is at the core of everything we do. Our manufacturing team is
committed to rigorous quality and we check every unit before it ships. Epsilon is ISO 9001 certified
and ISO/IEC 17025 accredited, including our traceable laser interferometer calibrator – reasons that
customers around the world trust Epsilon. Explore our scope of accreditation and quality system
certificates here.
• Responsive–talk to our experts anytime: When you reach out to Epsilon, you can
expect prompt, personalized assistance from a degreed engineer well-versed in materials testing and
extensometers. Whether you need help selecting an extensometer or need help troubleshooting a
problem, our experts are readily available to provide guidance. If you need a repair, our service is timely
and reliable.
1
Interfacing
Epsilon extensometers
to test equipment.
Compatibility
All of Epsilon’s strain gaged transducers employ a full Wheatstone bridge design. They
are powered by an excitation voltage, typically between 5 and 10 VDC. The output of the
extensometer is proportional to the excitation. For this reason the calibrated output is
often expressed as a mV/V value. An extensometer with a full scale span of 2.345 mV/V
will have a full scale output of 23.450 mV if the excitation is 10V. This span data is
All strain gaged sensors must be connected to some external electronics to provide
readings. The electronics provide the excitation and normally amplifies the sensor’s
output to a high level DC voltage. This resultant voltage is used for readout or control of
the test machine. In digital systems the voltage output is converted via data acquisition
hardware into engineering units of strain. In instances where a chart recorder or X-Y
recorder is used, the output is set to easily yield a specified strain/cm on the graph.
When any new device like an extensometer is first used, the sensor must be calibrated
with the electronics to ensure proper configuration. There are several ways to accomplish
this. Generally the process is very straightforward. If your extensometer will be connected
to an available strain channel in your test controller, Epsilon can normally supply the unit
with the correct connector to plug directly in. For external data acquisition systems, a
strain gaged signal conditioning module capable of providing the excitation is required.
Often this is part of the data acquisition system. For systems that require high level
inputs or for use with chart recorders and X-Y plotters, Epsilon offers optional signal
conditioning electronics.
i ng
and resolution requirements for ASTM E83 Class B-1 for 6 mm
a c
gauge length and greater extensometers and ISO 9513 Class
0,5 over the full measuring range of the calibrator. Periodic
recalibration of the calibrator can be performed by a third party
calibration service or by sending the unit to Epsilon Technology. er
c f
int alibration
y calibration services such as the equipment manufacturer or
B
independent calibration service
Epsilon’s extensometers can be calibrated with test controls by
torque
any third party calibration service with the capability of calibrat
ing extensometers. Many customers have their entire test
machine re-calibrated annually by the service department of the
manufacturer. This includes the load cell, extensometers and
any other installed sensors. Most calibration services will have
no difficulty calibrating Epsilon’s extensometers.
3
OUTSTANDING PERFORMANCE FEATURES IN EVERY MODEL
• Rugged construction withstands constant handling and mounting
• Most models may be left on through specimen failure
• Light weight to minimize specimen influence
• Most models operate in both tension and compression
• Most models are capable of being used in cyclic tests
• Low operating force, normally less than 40g, with many under 20g
• Easy to attach to specimens, with quick attach kits for most models
• Immersible in many non-conductive fluids
• Initial gauge length accurately established
Performance • All come with foam lined case
Features
Backed by many years of experience
Over forty years of experience in materials testing and extensometer design combine
to provide the best performing extensometers in the industry. Epsilon’s experienced
staff combined with our factory direct sales structure means if you have questions, you
can speak with an expert to help resolve your issue. Our extensometers are the result
of design refinements based on the experiences and inputs from customers over many
years.
High accuracy, exceeding requirements of ASTM, ISO, and many other test standards
All of Epsilon’s extensometers are designed for very high accuracy, with performance
significantly better than required by various testing standards. Epsilon’s extensometers
adhere to the highest requirements of ASTM E83 and ISO 9513, where applicable. For all
other units, linearities of better than 0.15% of full scale measuring range are commonly
achieved.
All units ship with an ISO 17025 accredited test certificate. Each extensometer is
individually calibrated using traceable electronics, with relevant data provided on the test
certificate.
Epsilon extensometers are sold factory direct. Coupled with our innovative design, the result
is substantial cost savings to your company, with world class performing products.
Unique dual flexure design combined with overtravel stops for ruggedness
Nearly all models use a dual flexure design, which protects the extensometer from
undesired motions. This design isolates the sensing element from side forces and
accelerations in dynamic tests. Nearly all out-of-plane errors are eliminated.
Certain items such as knife edges and ceramic rods wear under
a rran ty
w
Epsilon Technology takes pride in ensuring that our experts are
yea r
available to speak with customers. If you have an issue you wish
one nt standards
highstterinstge
g
to discuss, please contact us with your questions.
quality
5
Can Epsilon extensometers be left on through specimen failure?
Yes. All Epsilon standard extensometers are designed to withstand remaining on the sample through
specimen failure. On certain materials, such as high strength metals, knife edges will wear out faster if the
extensometer is left on through failure. A spare set of knife edges is included.
Questions The majority of Epsilon’s extensometers are strain gaged transducers which may be connected to most
brands of materials testing controls. If your controls have the signal conditioning module for a strain
gaged extensometer, we can supply the unit with the necessary connector to plug in directly. If you are
using a data acquisition board to acquire test data, the extensometers can almost always be interfaced
properly. Some of our extensometers use capacitive sensing technology and these include the required
electronics.
If your controls are designed for LVDT type extensometers only, we can provide the electronics to work
with our extensometers. Available electronics are covered in this catalog. This is also ideal for older test
machines, which may not have any extensometer electronics, allowing the output to run a chart recorder
or plotter, or interface to a data acquisition board.
The Epsilon Shunt Calibration System helps make calibrating the electronics for the extensometer quick
and easy. This also allows you to send your extensometer back to Epsilon for periodic recalibration. For
further details on shunt calibration see page 124.
Generally speaking, Epsilon’s extensometers will meet the higher levels of accuracy requirements in
today’s standards, such as ASTM E83. You can thus be assured that reasonably accurate measurements
at the low end of the range can still be made.
“ I use Epsilon extensometers because they are rugged, well built and with high quality and technical
economical. I find their versatility to be their most appealing aspect. performances.”
JOHN DINA
We interface them with several data
LABORATOR DINAMIC, ROMANIA
acquisition systems as well as testing
machines. We use them in traditional
testing modes to non-traditional, stand “ … With the fastest repairs completed in less than two weeks (from
the moment it was dispatched overseas from our factory to the
alone applications. It’s the versatility of
moment it was received again). Our previous extensometer supplier
these instruments that makes Epsilon
never managed a turnaround in less than eight weeks. For a front line
Model 3542-2 inch extensometer extensometers a perfect fit for our test
piece of equipment that is entirely unacceptable.”
with a Model 3575AVG r-Value laboratory.”
extensometer in use determining deep MIKE DAVIES
RICK PEARSON
drawing sheet metal properties. CYTEC, UNITED KINGDOM
ANDERSON LABORATORIES, INC.
“ E psilon’s products, technical support and service on repairs are “ We use Epsilon extensometers for their
very easy. We have never before experienced such a well organized high quality, stability and ruggedness.
company. We are in Austria, but it is much faster and easier to buy When we do eventually damage an
high temp extensometers via the US instead of from nearer European extensometer, Epsilon has, without fail,
companies! The technical support is very good, since every question offered excellence of service we would
is answered in less than 24 hours! Other companies take weeks to like from all of our vendors. Epsilon has
answer – if they answer at all.” provided custom engineering support to
MARTIN RIEDLER maximize reliability after many cycles of
Department Product Engineering
MONTANUNIVERSITÄT LEOBEN, AUSTRIA
specimen ruptures.”
Polyethylene geogrid undergoing
pullout testing in TRI’s Compact SHAWN ARNETT
Connection Device using a TEXAS RESEARCH INSTITUTE
“ ... I have been doing testing for over 15 years and have used Epsilon specially designed Model 3542
extensometer.
extensometers for more than seven years (3542 series). Your
extensometers represent the best value for their cost in the industry.
... Since, we can “leave” the extensometer until break in most
“ I have been really happy with all extensometers purchased from you:
applications (because of the robust good quality, high precision, friendly.”
design), we can get invaluable GREGORY BANAS
information on the material evaluated. Senior Research Engineer
UNIVERSITY OF ILLINOIS
… The response time in getting a
new unit is by far the shortest in the
industry.”
Model 3555 high temperature BRUNO BELANGER
extensometer being used at President and CEO
550 °F in the determination BCOMTESTING, INC.
of mechanical properties of an Visit our website at www.epsilontech.com
aluminum alloy used in an engine Contact us for your special testing requirements.
head application.
7
8
Epsilon ONE® Non-Contact Optical Extensometers
Non-Contact Extensometers
SLW 6/14/2018
STOCK SIZE CHECKED DATE DWG. NO. REV.
N/A 0
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION FINISH SIZE SCALE SHEET
REVISIONS
THIRD ANGLE PROJECTION
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
A 1:2.5 1 OF 1
9
Epsilon ONE
®
MODEL Optical Non-Contact Extensometers
Reset and Laser Alignment features maximize ease of use and testing
• Always real-time: Post-processing is never required, even at the highest data • Real-time digital output: High-speed data stream including APIs for control
rates. and status, and examples for automation and integration.
• Faster throughput with Instant Reset: Auto-start repetitive tests without • Better Strain Control: Built-in high speed 16-bit analog output; not
touching the extensometer or software. susceptible to unpredictable cyclic bias errors typical of DIC systems.
• Reliable, automatic mark detection: Robust tracking of bright or dark marks • Versatile Output Modes: output ±10V as % Strain, Length (mm), or
beyond 1000% strain and speeds >1500 mm/second. Elongation (mm).
• Laser Assist Alignment System: Provides an instant visual spot-check for • Applicable for testing with many ISO and ASTM standards, including:
- ISO 6892-1, 527-2, 527-4, 527-5
specimen alignment and optics positioning. - ASTM E8, E9, D3039, D638, A370, D3552, E646
• Precision Telecentric Design: Epsilon ONE’s telecentric lenses prevent • Turn-key: Each base package includes
common sources of error. See the Tech Note at www.epsilontech.com - Optics Package with laser-assist alignment system
• Fully factory calibrated: Epsilon calibrates using the industry’s most - Lighting Module
- Sensor Controller
comprehensive process to correct for scaling, skew, lens distortion, and
- Mounting Interface Subassembly
uneven lighting. A2LA accredited factory calibration, traceable to the SI; no - Specimen Marking Kit
grids or bars are required for calibration. - Cables and software
• Cleaner workspace: No need for an additional computer and monitor; the • Patented design
included Software User Interface has very low resource requirements and can
• Includes high quality foam lined case.
run on the test machine’s computer.
• Optional Touch Interface: Access and control the Epsilon ONE without a
computer.
• Retractable high-stiffness mounting: Industry-leading ease-of-use while
maintaining maximum dynamic range and vibration rejection.
• Selectable multi-line specimen marking: Automatically identify and report the
region of highest strain concentration, in real time.
• Wide range of selectable filter and optical settings enable high performance
with many different materials and specimens.
• Faster Testing: Save time with industry-leading 200+ Hz dynamic range and
automatic gain compensation filters.
Optics Packages
Telecentric Design
Many applications involve specimens that straighten or grips
that are free to align under tensile loading. Unlike conventional
ONE-52PT-System lenses, telecentric lenses are insensitive to potential
Precision Telecentric Optics
inaccuracies caused by these out-of-plane motions. With a
telecentric lens, the image of the test specimen seen by the
camera’s sensor is the same size even if the specimen moves
closer to the Optics Package or further away.
The benefit: full strain measurement accuracy is maintained
even if the specimen or grips move out of the testing axis (“out
of plane”) during the test. Conventional entocentric lenses,
which are widely used by other manufacturers of non-contact
extensometers, cannot match this performance.
ONE-200CE-System
Conventional Entocentric Optics
Options
Mounting Systems for testing machine base mount, T-slot column mount, or cylindrical column mount
ONE-TI-1 Touch Interface
ONE-BIS Barrier Interlock Systems for setups where Epsilon ONE is installed behind the test area (opposite the test machine operator)
Customized specimen marking templates
Connectors to interface to nearly any brand of test equipment
CERTIFIED
MODEL ONE-MS-04
ALL SURFACES
64
OR BETTER
CAD GENERATED
DRAWING, DO NOT
MANUALLY UPDATE
3 mmEpsilon Technology Corp.
Jackson, WY, USA 83001
TOLERANCES ARE: DO NOT SCALE
2 PLACE
INCHES
3 PLACE
INCHES
4 PLACE
INCHES
ANGLES
DRAWING Epsilon One Catalog
±.03 ±.005 ±.0010 ±1°
MATERIAL DRAWN DATE
SLW 6/14/2018
STOCK SIZE CHECKED DATE DWG. NO. REV.
N/A 0
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION FINISH SIZE SCALE SHEET
REVISIONS
THIRD ANGLE PROJECTION
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
A 1:2.5 1 OF 1
180 mm 5%
INCHES INCHES INCHES
10 mm
±.03 ±.005 ±.0010 ±1°
MATERIAL DRAWN DATE
SLW 6/14/2018
STOCK SIZE CHECKED DATE DWG. NO. REV.
N/A 0
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION FINISH SIZE SCALE SHEET
REVISIONS
THIRD ANGLE PROJECTION
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
A 1:2.5 1 OF 1
SLW 6/14/2018
REVISIONS
THIRD ANGLE PROJECTION
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
A 1:2.5 1 OF 1
SLW 6/14/2018
REVISIONS
THIRD ANGLE PROJECTION
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
A 1:2.5 1 1
344
OF
10 mm >1000% 480 mm
220 94
applications and for measuring strain values of ~2% or greater; suitable for 8.6 3.7 148
5.8
25 mm >1000% 465 mm
smaller strains in some applications 94
3.7 148
5.8 50 mm 880% 440 mm
• 500 mm field of view and 270 mm working distance 100 mm 390% 390 mm
• Any gauge length between 10 mm and 400 mm 200 mm 145% 290 mm
400 mm 23% 90 mm
107
408 4.2
16.1
Example: ONE-78PT-System, ONE-MS-01, and ONE-TI-1: Precision Telecentric Lens, 78 mm Field of View, mounting for T-slots on the column of the
107
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION [mm] SIZE
ONE-D08
SCALE DATE SHEET
A
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
inch A 1:4 12/13/2019 2 OF 5
measure the spacing between reflective tape strips on the sample. The
Easy to use.
The visible laser light is simply aimed at the specimen, which has small reflective
tape strips set at the gauge length desired. The extensometer displays the actual
measured gauge length. If desired, the zero button will offset the output to zero.
Laser extensometer high temperature As the specimen is tested, the display will then read the elongation directly.
clip-on reflectors
The analog output and RS-232 interface are easily connected to existing
controls or data acquisition systems.
The reflective tape can be used at temperatures up to 80 °C (180 °F). High
temperature clip-on reflectors may be used as an alternate to tape reflectors.
These are re-usable and available as an option. They are rated for use to 425 °C
(800 °F).
Specifications
Model LE-05
Measurement Range: 8 to 127 mm (0.3 to 5 inches))
Max. Resolution: 0.001 mm (0.0001 inches)
Linearity 1: ±0.01 mm (±0.0004 inches)
Repeatability :1
±0.005 mm (±0.0002 inches)
Max. Scan Rate: 100 scans/second
Target Distance:
250 mm nominal, 500 mm max., selectable
10 inches nominal, 20 inches max., selectable
Zero Suppression: Reading may be set to zero anywhere in measuring range
Scan Line Orientation: Vertical
Scan Averaging: Moving window averaging over a selectable number of scans
Analog Output: 16 bit, ±10 VDC standard
Full Scale Ranges: 2.0, 5.0, 10, 20, 50, or 100 mm
0.1, 0.2, 0.5, 1.0, 2.0, or 5.0 inches
Digital Communications: RS-232 serial communications, standard 3 wire
Selectable Baud Rate: 9600, 4800, 2400, or 1200
Display: 2 line, 16 character digital display, backlit LCD
Power Input: 115 VAC ±10%, 50/60 Hz standard
230 VAC ±10%, 50/60 Hz optional
Size: 381 L x 180 H x 114 W mm (15 L x 7.1 H x 4.5 W inches)
Weight: 6 kg (13 lbs.)
Mounting Provisions: 1/4-20 UNC tapped holes in base (4)
Laser Source: Diode laser, 670 nm, <1 mW maximum scanned output
CDRH Certified Class II laser instrument
Options: Consult factory for options like reflective clips for high temperature use
1
Over optimum displacement range at calibrated distance
Note: Specifications measured at 25 °C and 50% relative humidity.
Model 3543-SR-xxxx-xxxx-xx
Large Gage Length Extensometer
MODEL 3800-xxxx-xxx
19
MODEL 3542 Axial Extensometers
General purpose extensometers for axial tensile, compression, and
Extensometers for
Composites
Compression Testing
Model 3542 configured for a very Standard quick attach wire forms included for
Models 3542 and 3442 extensometers
large specimen diameter round and flat samples
can be furnished to clip directly onto
composites compression fixtures, such
•
as for ASTM D695. These use specially
made wire forms for the test fixture.
See the Model 3542 extensometer videos Model 3542 mounted on a
Contact Epsilon for details.
D695 compression fixture for
Also see the Model 3442 miniature composite materials
extensometer.
Options
Quick attach kit wire forms or cable attachment for large specimens
Adapter kits to change gauge lengths
Connectors to interface to nearly any brand of test equipment
Special coatings and stainless steel knife edges available for biomedical tests
Specialty knife edges (see page 106)
CERTIFIED
MODEL 3542 EXAMPLES
EPSILON TECH–Innovative designs
21
and factory direct sales.
MODEL 3442 Miniature / Low Profile Extensometers
Small profile and ultra-light weight, these units are appropriate for
testing small and delicate samples yet rugged enough for daily use on
Extensometers for
Composites
Compression Testing
Models 3542 and 3442 extensometers
can be furnished to clip directly onto
Model 3442 with 25 mm gauge length testing
carbon fiber tow composites compression fixtures, such
as for ASTM D695. These use specially
made quick attach kit wire forms for
See the Model 3442 extensometer videos the test fixture. Consult the factory for Rubber band and spring attachment options included with
specifics. Models 3442 and 3542
Also see the Model 3542 extensometer.
• Gauge length pin helps set gauge length accurately for all gauge length Gauge Length
configurations. METRIC
1 Measuring Range
-003M 3.0 mm
• All models can measure in both tension and compression and can be used 1 METRIC
-004M 4.0 mm
for cyclic testing. -005M
1
5.0 mm -005M ±0.5 mm
• Mechanical overtravel stops in both directions. -006M 6.0 mm -010M ±1.0 mm
-008M 8.0 mm -020M +2.0 mm/-1.0 mm
• Rugged, dual flexure design for strength and improved performance. Much -025M
2
+2.5 mm/-1.0 mm
-010M 10.0 mm
stronger than single flexure designs, this also allows cyclic testing at -012M 12.0 mm -050M
2
+5.0 mm/-1.0 mm
higher frequencies. -0125M 12.5 mm -100M
2
+10.0 mm/-1.0 mm
2
-020M 20.0 mm -125M +12.5 mm/-1.0 mm
• Gauge length adapter kits enable configuration of multiple gauge lengths
-025M 25.0 mm U.S.A.
with one extensometer.
-050M 50.0 mm -005T ±0.050”
• Replaceable arms and spacers for ease of repair. -010T
2
+0.100”/-0.050”
U.S.A.
2
• High and low temperature options extend operation from as low as -270 °C -0025 0.250 in -025T +0.250”/-0.050”
2
to +200 °C (-454 °F to +400 °F). -0030 0.300 in -050T +0.500”/-0.050”
-0050 0.500 in
• Includes the Epsilon Shunt Calibration System for on-site electrical -0064 0.640 in
calibration. -0100 1.000 in
• Includes high quality foam lined case. -0200 2.000 in
Specifications
• •
Model Number 3442- __ __ __ __ - __ __ __ __ - __ __
Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max. •
Output: 2 to 4 mV/V nominal, depending on model Temperature Range
Accuracy: Standard configurations meet ASTM E83 class B-1 accuracy
requirements for gauge lengths ≥6 mm and class B-2 for ≤5 -LT -270 ˚C to 100 ˚C (-454 ˚F to 210 ˚F)
mm. All standard configurations meet ISO 9513 class 0,5. A -ST -40 ˚C to 100 ˚C (-40 ˚F to 210 ˚F)
test certificate is included. -HT1 -40 ˚C to 150 ˚C (-40 ˚F to 300 ˚F)
Linearity: ≤0.15% of full scale measuring range -HT2 -40 ˚C to 200 ˚C (-40 ˚F to 400 ˚F)
Temperature Range: Standard (-ST) is -40 °C to +100 °C (-40 °F to 210 °F) -LHT -270 ˚C to 200 ˚C (-454 ˚F to 400 ˚F)
Optional (-LHT) is -270 °C to +200 °C (-454°F to 400 °F) 1 Available in -010M and -020M measuring ranges only; meets accuracy requirements
Cable: Integral, ultra-flexible cable, 2.5 m (8 ft) standard for ASTM E83 class B-2. Gauge lengths of 6 mm or larger are recommended.
Standard Quick Attach Kit: Fits round samples 0.5-13 mm (0.02-0.5 inch) diameter and 2 Extended compressive measuring ranges are available – inquire with Epsilon.
CERTIFIED
Tethering
Wireform
units are for long gauge length applications where low-level strain
The dual flexure design makes the 3542L very rugged and insensitive
to vibrations. These extensometers are designed for testing a wide
range of materials including metals, plastics, composites and ceramics.
Epsilon’s Model 3543 is recommended for applications requiring long
gauge lengths and larger measuring ranges.
The Model 3542L comes standard with Epsilon’s quick attach kit,
making it easy to mount the extensometer on the test specimen. The
quick attach kit can be removed, allowing mounting of the extenso
meter with springs or rubber bands.
Model 3542L with 8 inch gauge Model 3542L extensometers are strain gaged devices, making them
length and +0.5 inch/-0.25 inch
measuring range compatible with any electronics designed for strain gaged transducers.
Most often they are connected to a test machine controller with
electronics for a strain channel, and Epsilon will equip the extensometer with
a compatible connector that is wired to plug directly into the controller. For
systems lacking the required electronics, Epsilon can provide a variety of signal
conditioning solutions that enable connecting to data acquisition systems or other
equipment.
For gauge lengths less than 100 mm (4 inches), see Model 3542.
See the electronics section of this catalog for available signal conditioners and
strain meters.
• All models can measure in both tension and compression and can be used Gauge Length
Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max. -LT -270 °C to 100 °C (-454 °F to 210 °F)
Output: 2 to 4 mV/V, nominal, depending on model -ST -40 °C to 100 °C (-40 °F to 210 °F)
Accuracy: Standard configurations meet ASTM E83 class B-1 and ISO -HT1 -40 °C to 150 °C (-40 °F to 300 °F)
9513 class 0,5 requirements for accuracy. A test certificate is -HT2 -40 °C to 200 °C (-40 °F to 400 °F)
included. -LHT -270 °C to 200 °C (-454 °F to 400 °F)
Linearity: ≤0.15% of full scale measuring range
Temperature Range: Standard (-ST) is -40°C to +100°C (-40 °F to 210°F) Example: 3542L-200M-0125M-ST: 200 mm gauge length,
Optional (-LHT) is -270 °C to +200 °C (-454°F to 400 °F) +12.5 / -6.0 mm measuring range, standard temperature
option (-40 °C to 100 °C)
Cable: Integral, ultra-flexible cable, 2.5 m (8 ft) standard
Standard Quick Attach Kit: Wireforms are included for round samples up to 25 mm
diameter (1.0 inch) and flats to 12 mm thick by 31 mmModelwide 3542L Visit our website at www.epsilontech.com
(0.5 inch by 1.25 inch) wireforms are available for many other Contact us for your special testing requirements.
specimen sizes - contact Epsilon
Operating Force: Depends on model configuration, less than 30 g typically
Options
Quick attach kit wire forms for large specimens
Adapter kits to change gauge lengths
Connectors to interface to nearly any brand of test equipment
Special coatings and stainless steel knife edges available for biomedical tests
Specialty knife edges (see page 106)
CERTIFIED
design separates into two halves and the extensometer may be left on
long samples and large measuring ranges are required. They are ideal
See the Model 3543 extensometer video Special Model 3543 with
ability to work on test
samples that twist up to 15°
during the test
• Full bridge, 350 ohm strain gaged design for compatibility with nearly any
Gauge Length
test system.
METRIC
• A ll standard units meet ASTM Class B-2 requirements for accuracy. -050M 50.0 mm Measuring Range
Suitable for measuring 0.2% offset yield stress, plastic deformation and -100M 100.0 mm
METRIC
elongation at failure. For measuring modulus and yield strain, Model 3542, -150M 150.0 mm
-025M +25 mm
3542L or Epsilon ONE® is required. -200M 200.0 mm
-050M +50 mm
-250M 250.0 mm
• Rugged design for reliable testing. -100M1 +100 mm
-500M 500.0 mm
• Standard quick attach kit for quick mounting to specimens. -600M 600.0 mm U.S.A.
• Hardened tool steel knife edges are easily replaced. A spare set comes with -100T +1.00”
U.S.A.
every extensometer. -200T +2.00”
-0200 2.000”
-400T 1 +4.00”
-0400 4.000”
• High temperature option extends operation to +150 °C (300 °F).
-0600 6.000”
• Replaceable arms and spacers for ease of repair. The optional gauge length -0800 8.000”
spacers allow the gauge length of the extensometer to be easily increased -1000 10.000”
for different testing requirements. -2000 20.000”
-2400 24.000”
• Includes the Epsilon Shunt Calibration System for on-site electrical
calibration.
• •
• Includes high quality foam lined case. Model Number 3543- __ __ __ __ - __ __ __ __ - __ __
•
Specifications
Temperature Range
Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max.
-ST 1 ˚C to 100 ˚C (33 ˚F to 210 ˚F)
Output: 2 to 4 mV/V nominal, depending on model
-HT1 1 ˚C to 150 ˚C (33 ˚F to 300 ˚F)
Accuracy: Standard configurations meet ASTM Class B-2 Model 354
requirements for accuracy. Suitable for measuring 0.2% Large Gag
Model
1 Not available in 50 mm or 3543-SR-xxxx-xxxx-xx
2 inch gauge length models.
offset yield stress, plastic deformation and elongation at Large Gage Length Extensometer
failure. For measuring modulus and yield strain, Model Example: 3543-200M-100M-ST: 200 mm gauge length,
3542, 3542L or Epsilon ONE® is required. +100 mm measuring range, standard temperature range
Linearity: ≤ 0.2% of full scale measuring range (1 ˚C to 100 ˚C)
Temperature Range: Standard (-ST) is 1 °C to +100 °C
(33 °F to 210 °F)
Cable: Ultra-flexible cable 2.5 m, (8 ft) standard See more extensometry at www.epsilontech.com
Contact us for your special testing requirements. Mode
Standard Quick Attach Kit: Fits round samples up to 25 mm diameter (1.0 inch) Large
and flats to 12 mm thick by 31 mm wide
(0.5 inch by 1.25 inch)
Operating Force: 125 g typical
Options
have very long measuring ranges. Their unique design allows testing to
Specifications
Options
Visit our website at www.epsilontech.com
Contact us for your special testing requirements.
Adapter kits to change gauge lengths.
Connectors to interface to nearly any brand of test equipment.
CERTIFIED
25 mm or 1” gauge length
50 mm or 2” gauge length
MODEL 3448IND-0100-xxx
( with Induction Heating option ) High Temperature
3549 High Temperature Hot Mountable Furnace Axial Extensometers
Extensometers (1200 °C or 1600 °C)
(Above 200 ˚C or 400 ˚F)
CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION [mm] SIZE
3549-LD
SCALE DATE SHEET
ART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
inch A 1:2 10/3/2012 1 OF 1
N/A SAA
FORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION FINISH
A 1:4
SIZE SCALE SHEET
CLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
REVISIONS NONE 1 OF 1
7642 Catalog
HE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION [mm] SIZE
7642
SCALE DATE SHEET
R DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
inch A 3:2 6/25/2015 1 OF 1
31
MODEL 3448 High Temperature Self-Supporting Furnace Extensometers (1200 °C)
Designed for use with furnaces and induction heating systems,
• Includes the Epsilon Shunt Calibration System for on-site electrical 1 For 10 mm and 0.5 inch gauge lengths, the 5% strain range is only available with short
ceramic rods.
calibration. 2 Not available in 50 mm or 2.0 inch gauge lengths.
• Rugged, dual flexure design for strength and improved performance. Example: 3448-0100-020: 1.000 inch gauge length, +20%/-10%
• Includes high quality foam lined case, a spare set of ceramic rods, and measuring range, temperature range of ambient to 2200 °F
eight ceramic fiber cords.
Visit our website at www.epsilontech.com
Contact us for your special testing requirements.
Specifications
Options
CERTIFIED
hot test sample in a few seconds. With low sensitivity to vibrations, this
• Rugged, dual flexure design for strength and improved performance. Temperature Range
• Mechanical overtravel stops in both directions.
-ST Ambient to 1200 ˚C (Ambient to 2200 ˚F)
• All units come with either high purity alumina ceramic rods (1200 °C) or -HT Ambient to 1600 ˚C (Ambient to 2900 ˚F)
alpha grade silicon carbide rods (1600 °C).
1 Not available in 10 mm, 12.5 mm, or 0.5 inch gauge lengths.
• The 3549 includes quick attach connectors for the liquid cooling lines and the
electrical connections, which allow for easy installation of the extensometer 2 Not available in 50 mm or 2 inch gauge lengths.
Specifications
Options
Model EPS170 constant-temperature recirculating chiller - see the Options tab on the web
page for important details about liquid cooling requirements
High temperature option (-HT suffix) for use to 1600 °C
Load frame mounting brackets
Connectors to interface to nearly any brand of test equipment
Rod tips can be straight chisels or conical tips; specify when ordering
MODEL 3549 EXAMPLE
EPSILON TECH–Broadest product Epsilon Technology Corp.
Jackson, WY, USA
35
range with unrivaled quality. 3549 Line Drawing
MODEL 7650A High Temperature, Low Strain, Extended Performance Capacitive Extensometers (1200 °C or 1600 °C)
This high precision extensometer measures axial strains on specimens at
specimens in seconds.
• Quick-disconnect liquid cooling fittings and signal cables. -ST Ambient to 1200 ˚C (RT to 2200 ˚F)
• Includes high quality foam lined case and a spare set of rods. -HT Ambient to 1600 ˚C (RT to 2900 ˚F)
Specifications
Example: 7650A-025M-020M-ST: 25 mm gauge length,
Analog Output: User specified, ±10VDC typical, ±10.8VDC rail +2.0 / -1.0 mm measuring range, standard temperature
Digital Output: 24 bit high speed Ethernet output with built-in web interface range (room temperature to 1200 °C)
Cyclic Testing: up to 10 Hz, depending on test system and test amplitude
Accuracy: Standard configurations meet ASTM E83 class B-1 and ISO 9513
class 0,5 requirements for accuracy. A test certificate is included.
Rod lengths >250 mm (10”) can affect the final class rating.
Linearity: 11 point digital linearization, ≤0.1% FS typical linearity CERTIFIED
Hysteresis: ≤0.1% FS typical
Resolution: <75 PPM (0.0075%FS) RMS @ 4 kHz, < 6PPM (0.0006%FS) @ 100 Hz
at gauge length
Filter: Selectable 100 Hz analog and 2 Hz - 3 kHz digital filters Visit our website at www.epsilontech.com
Temperature Range: Standard (-ST) is to 1200 °C (2200 °F), optional Contact us for your special testing requirements.
(-HT) 1600 °C (2900 °F)
Sensor Cable: 2 m (6.5 ft) room temperature cable
Output Cable: Flexible 2.4 m (8 ft) analog output cable
Coolant Interface: Two barbed hose fittings for 1/8” (3.2 mm) ID coolant hoses
Operating Force: <30 grams typical
Contact Force: <560 grams typical
Environment: Recommended for testing in dry air, inert / non-corrosive gases, or
vacuum
Power: Includes power supply
Options
High temperature option (-HT suffix) for use to 1600 °C
Load frame mounting brackets
Bulkhead adapters for use in vacuum chambers
Model EPS170 constant-temperature recirculating chiller - see the Options tab on the web
page for important details about liquid cooling requirements
Connectors to interface to nearly any brand of test equipment
Rod tips can be straight chisels or conical tips; specify when ordering
MODEL 7650A EXAMPLE
Epsilon TECH–World class quality
37
at substantial savings.
MODEL 3648 High Temperature, Ultra-Low Contact Force Capacitive Extensometers (1200 °C or 1600 °C)
This model was designed for applications that require ultra-low contact
force when using split type materials testing furnaces or induction heaters.
It features very low specimen contact force and includes a slide bracket
Specifications • •
Model Number 3648-__ __ __ __ - __ __ __ - __ __
Output: User specified, ±5 VDC or ±10 VDC typical
•
Accuracy: Standard configurations meet ASTM E83 class B-1 and ISO 9513
class 0,5 requirements for accuracy. A test certificate is included.
Rod lengths >250 mm (10”) can affect the final class rating. Temperature Range
Linearity: 0.15% of full scale measuring range (rod length dependent) -ST Ambient to 1200 ˚C (RT to 2200 ˚F)
Temperature Range: Standard (-ST) is to 1200 °C (2200 °F), optional -HT Ambient to 1600 ˚C (RT to 2900 ˚F)
(-HT) 1600 °C (2900 °F)
Cable: Integral, ultra-flexible cable, 2.5 m (8 ft) standard Example: 3648-025M-010M-ST: 25.0 mm gauge length,
Coolant Interface: Two barbed hose fittings for 1/8” (3.2 mm) ID coolant hoses ±1.0 mm (±4 % strain) measuring range, standard
Contact Force: Adjustable up to 150 g (30-50 g typically used) temperature option (room temperature to 1200 °C)
Operating Force: <10 g typical
Power: Includes power supply for your country (specify)
Options
Model EPS170 constant-temperature recirculating chiller - see the Options tab on the web
Visit our website at www.epsilontech.com
page for important details about liquid cooling requirements
Contact us for your special testing requirements.
High temperature option (-HT suffix) for use to 1600 °C
Load frame mounting brackets
Connectors to interface to nearly any brand of test equipment
Rod tips can be straight chisels or conical tips; specify when ordering
VREF Module (see p. 125)
SLW 2/21/12
at substantial savings.
STOCK SIZE CHECKED DWG. NO. REV.
N/A SAA
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION FINISH
A 1:4
SIZE SCALE SHEET
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
REVISIONS NONE 1 OF
MODEL 7642 High Temperature Un-Cooled Extensometers (700 °C)
For use in environmental chambers where the entire extensometer
cooling.
Options
Gauge length adapter kits (for use at temperatures ≤ 300 °C (570 °F))
Connectors to interface to nearly any brand of test equipment
Bulkhead adapters for vacuum chambers
Dual-channel DT6229 controller available
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION
7642
SIZE SCALE DATE SHEET
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
inch A 3:2 6/25/2015 1
42
3541 Fracture Mechanics Clip- On Gages
Fracture Mechanics
3548 COD High Temperature COD Gages (1200 °C or 1600 °C) Clip-On Gages
Grip/Clevis Clearance
(Avoid contact)
mm 7641-OTLN-TL A
(inch)
SIZE SCALE DATE SHEET
A 1:2 2 OF 4
43
MODEL 3541 Fracture Mechanics Clip-On Gages
For fracture mechanics studies, these COD gages are in
materials.
• Fully enclosed gages are protected from accidental damage. Gauge Length
• Sharpgrooves per ASTM E1820, E813, and E399 for improved stability METRIC Measuring Range
with a slot for the ceramic rods. These liquid-cooled COD gages are for use
to 1200 °C (2200 °F). The high temperature option allows use to 1600 °C
(2900 °F). They are specifically designed for fracture mechanics testing.
• All units come with either high purity alumina ceramic rods (1200 °C) or METRIC METRIC
alpha grade silicon carbide rods (1600 °C). -005M 5.0 mm -025M +2.5 mm
-008M 8.0 mm -040M +4.0 mm
• Includes the Epsilon Shunt Calibration System for on-site electrical -010M 10.0 mm -070M +7.0 mm
calibration. -012M 12.0 mm -100M +10.0 mm
1
-020M 20.0 mm -120M +12.0 mm
• Rugged, dual flexure design for strength and improved performance.
• Includes high quality foam lined case and a spare set of ceramic rods. U.S.A. U.S.A.
-0020 0.200” -100T +0.100”
-0030 0.300” -150T +0.150”
Specifications -0040 0.400” -200T +0.200”
Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max. -0047 0.475” -250T +0.250”
Output: 2 to 4 mV/V nominal, depending on model -0050 0.500” -500T +0.500”
Accuracy: Standard configurations meet existing ASTM E1820 requirements for
accuracy. A test certificate is included. Rod lengths >250 mm (10”)
can affect the final class rating.
Linearity: ≤0.15% of full scale measuring range, depending • •
on model Model Number 3548COD-__ __ __ __ - __ __ __ __ - __ __
Temperature Range: Standard (-ST) is to 1200 °C (2200 °F), optional •
(-HT) 1600 °C (2900 °F)
Cable: Integral, ultra-flexible cable, 2.5 m (8 ft) standard Temperature Range
Coolant Interface: Two barbed hose fittings for 1/8” (3.2 mm) ID coolant hoses
-ST Ambient to 1200 ˚C (Ambient to 2200 ˚F)
Operating Force: <30 g typical
-HT Ambient to 1600 ˚C (Ambient to 2900 ˚F)
Options
1 Only available in small measuring ranges (rod length dependent).
Model EPS170 constant-temperature recirculating chiller - see the Options tab on the web
page for important details about liquid cooling requirements Example: 3548COD-0050-200T-HT: 0.500 inch compressed
Load frame mounting brackets gauge length, +0.20 inch measuring range, high temperature
High temperature option (-HT suffix) for use to 1600 °C option (room temperature to 1600 °C (2900 °F))
Connectors to interface to nearly any brand of test equipment
Visit our website at www.epsilontech.com
Contact us for your special testing requirements.
CERTIFIED
any cooling.
The COD gage is supplied with the advanced DT6229 controller. The
standard output is a 0-10V analog signal, factory calibrated with the COD gage.
This system provides a number of functional enhancements including: built in
calibration and tare functions, multi-point linearization, analog and digital filters,
high speed digital output, and more.
Mounting the Model 7641 COD gage
The 7641 is readily interfaced with most existing test controllers or may be
directly connected to a data acquisition system, chart recorder, or a PC. The 7641
may be used for strain-controlled tests such as JIC.
• Digital controller and power supply included. Provides high level DC Model # Gauge Length Model # Measuring Range Total Length
voltage output with low noise. Easily interfaced to test controllers, data -030M 3.0 mm(0.12”) -055MV
1
5.5 mm(0.22”) 47.6mm(1.88”)
acquisition boards and chart recorders. -040M 4.0 mm(0.16”) -070MV
2
7.0 mm(0.28”) 56.5mm(2.23”)
- Includes high speed analog and digital outputs -050M 5.0 mm(0.20”) -080MV 8.0 mm(0.31”) 60.3mm(2.38”)
- Intuitive web-based user interface for setup, calibration, and data -060M 6.0 mm(0.24”) -090MV 9.0 mm(0.35”) 66.7mm(2.63”)
acquisition -070M 7.0 mm(0.28”) -035MA*
1
3.5 mm(0.14”) 51.1mm(2.01”)
- Built-in calibration reference and auto-zero features -080M 8.0 mm(0.31”) -045MA*
2
4.5 mm(0.18”) 59.9mm(2.36”)
- Multiple extensometer calibration files may be loaded for use with one -090M 9.0 mm(0.35”) -050MA* 5.0 mm(0.20”) 63.8mm(2.51”)
controller -100M 10.0 mm(0.39”) -055MA* 5.5 mm(0.22”) 70.1mm(2.76”)
- Multiple temperature-specific calibrations may be stored -110M 11.0 mm(0.43”)
- Selectable analog and digital filter options from 2 Hz to 3 kHz -120M 12.0 mm(0.47”)
• Ships fully calibrated with electronics (traceable to NPL (UK)) with user
specified voltage output.
• Mechanical over-travel protection. Installed Gauge Length is set by
• Rugged, dual flexure design for strength and improved performance. your specimen. Round DOWN to
• Includes high quality foam lined case. the nearest available size.
Specifications
Chamber wall
(Avoid contact)
49
L.3 Grip/Clevis Clearance
50
3540 Deflection Gages (Deflectometers) Deflection Gages
51
MODEL 3540 Deflection Gages (Deflectometers)
Widely used for measuring deformations in three- and four-point
1
Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max. -HT2 -40 ˚C to 200 ˚C (-40 ˚F to 400 ˚F)
1
Output: 2 to 4 mV/V, nominal, depending on model -LHT -270 ˚C to 200 ˚C (-454 ˚F to 400 ˚F)
Linearity: ≤0.25% of full scale measuring range
Temperature Range: Standard (-ST) is -40 °C to +100 °C (-40 °F to 210 °F) 1 Magnetic base not suitable for high temperature use; 50 °C (125 °F) max.
CERTIFIED
N/A SAA
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION FINISH
A 2:1
SIZE SCALE SHEET
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
REVISIONS NONE 1 OF 1
Transverse
3475 Miniature Transverse Diametral Extensometers and Diametral
Extensometers
MODEL 3575-200-xx
7675 Cataolg
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION [mm] SIZE
7675
SCALE DATE SHEET
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
inch A 3:2 6/25/2015 1 OF 1
55
MODEL 3575 Transverse (Diametral) Extensometers
Designed for general purpose transverse or diametral strain
• All models will measure both positive and negative displacements. -050M ±0.5 mm
-100M ±1.0 mm
• Easy to mount, with integral springs to keep the extensometer on the -250M ±2.5 mm
sample. -300M ±3.0 mm
-500M ±5.0 mm
• Self-supporting on the specimen.
• All standard units have linearity readings of 0.20% or better. U.S.A.
-020T ±0.020”
• Includes the Epsilon Shunt Calibration System for on-site electrical -050T ±0.050”
calibration. -100T ±0.100”
• Rugged, dual flexure design for strength and improved performance. Much -150T ±0.150”
stronger than single flexure designs, this also allows cyclic testing at -200T ±0.200”
higher frequencies.
• Includes high quality foam lined case and spare set of tool steel knife
edges.
•
Model Number 3575- __ __ __ __ - __ __
Specifications •
Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max.
Output: 2 to 4 mV/V, depending on model
Temperature Ranges
Linearity: ≤0.20% of full scale measuring range, depending
on model -LT -270 ˚C to 100 ˚C (-454 ˚F to 3575-xxx-xx
MODEL 210 ˚F)
Temperature Range: Standard (-ST) is -40 °C to +100 °C (-40 °F to 210 °F) -ST -40 ˚C to 100 ˚C (-40Transverse Extensometer
˚F to 210 ˚F)
Optional (-LHT) is -270 °C to +200 °C (-454°F to 400 °F) -HT1 -40 ˚C to 150 ˚C (-40 ˚F to 300 ˚F)
Cable: Integral, ultra-flexible cable, 2.5 m (8 ft) standard -HT2 -40 ˚C to 200 ˚C (-40 ˚F to 400 ˚F)
Specimen Size: Works with samples up to 25 mm (1 inch) width or diameter -LHT -270 ˚C to 200 ˚C (-454 ˚F to 400 ˚F)
±3 mm or ±5 mm measuring range
MODEL 3575-200-xx
MODEL 3575-xxx-xx
Connectors to interface to nearly any brand of test equipment Visit our website at www.epsilontech.com
Contact us for your special testing requirements.
CERTIFIED
•
Model 3475 Transverse
Use with Model 3442 axial extensometer to measure
Poisson’s ratio.
59 3475-Line-Drawing
STOCK SIZE CHECKED REV.
N/A SAA
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION FINISH
A
SIZE SCALE SHEET
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
REVISIONS NONE 2:1 1 OF 1
MODEL 3580 High Temperature Diametral Extensometers (1000 °C)
For transverse or diametral strain measurements at temperatures
flexure design.
Specifications •
Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max. Model Number 3580- __ __ __ __
Output: 2 to 4 mV/V nominal, depending on model 1 Total measuring range in either tension or compression. Specify direction of
Linearity: ≤0.15% of full scale measuring range, depending extensometer measuring range when ordering.
on model 2 Special order only.
Options
CERTIFIED
Specifications
CERTIFIED
Analog Output: User specified, ±5 VDC or ±10VDC typical, ±10.8VDC rail
Digital Output: 24 bit high speed Ethernet output with built-in web
interface
Linearity:
11 point linearization, ≤0.15% of full scale typical Visit our website at www.epsilontech.com
Resolution: <55 PPM (0.006%FS) RMS @4 kHz, <6 PPM Contact us for your special testing requirements.
(0.0006%FS) @100 Hz
Analog Filter:
Selectable 100 Hz analog and 2 Hz - 3 kHz digital filters
Temperature Range: Ambient to 700 °C (1300 °F). Use up to 800 °C is
possible – contact Epsilon for details. Springs may require
periodic adjustment or replacement after long-term testing
above ~600 °C.
Temperature Sensitivity (Gain): <100 PPM/°C (0.01%FS/°C) typical
Sensor Cable: 0.7 m (2.5 ft) tri-axial high temperature cable, plus 1.5 m
(5 ft) room temperature extension cable
Specimen Size: Fits round samples up to 25 mm (1.0 inch) diameter and
flats to 25 mm (1.0 inch) wide
Axial Extensometer Compatibility:
Compatible with model 7642 with gauge length ≥25 mm (1
inch); contact Epsilon if a shorter gauge length is required
Operating Force: 1-2 kgf (30-60 oz.) typical, depending on model
Environment: Recommended for elevated temperature testing in dry air,
inert / non-corrosive gases, or vacuum
Overall Dimensions: Contact Epsilon for overall dimensions
Power: Includes power supply
Options
Reverse cable exit available
Connectors to interface to nearly any brand of test equipment
Bulkhead adapters for vacuum chambers
Dual-channel DT6229 controller
Specialty knife edges (see page 106)
Epsilon Technology Corp.
Jackson, WY, USA
7675 Cataolg
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION [mm] SIZE
7675
SCALE DATE SHEET
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
inch A 3:2 6/25/2015 1 1
63
64
N
50.9
2.00
MODEL 3544-xxxx-xxx-xx
Circumferential Extensometer
MODEL 3909
Axial Asphalt Extensometer
(Simple Performance Test)
MODEL 3910
Asphalt Extensometer
MODEL 3911
Asphalt Extensometer
Indirect Tensile Test Model
3910 Extensometers for Creep Compliance and Tensile Strength Testing of Asphalt
3 inch [76] mm]
65
MODEL 3542RA Averaging Axial Extensometers
Designed primarily for compressive strength tests on rock, concrete
173
6.81
CERTIFIED
MODEL 3542RA2-0200-100-ST
MODEL 3542RA1 EXAMPLE 150 mm (6”) gauge length, fits samples from 50 to 150 mm (2” to 6”) diameter
METRIC METRIC
• Self-supporting on the specimen.
-025M 25.0 mm -125M ±1.25 mm
• Includes the Epsilon Shunt Calibration System for on-site electrical -050M 50.0 mm -250M ±2.50 mm
calibration.
U.S.A. U.S.A.
• Rugged, dual flexure design for strength and improved performance. -0100 1.000” -050T ±0.050”
• Includes high quality foam lined case. -0200 2.000” -100T ±0.100”
Specifications
Operating Force: <30 g typical per side -LT -270 ˚C to 100 ˚C (-454 ˚F to 210 ˚F)
-ST -40 ˚C to 100 ˚C (-40 ˚F to 210 ˚F)
Options -HT1 -40 ˚C to 150 ˚C (-40 ˚F to 300 ˚F)
-HT2 -40 ˚C to 200 ˚C (-40 ˚F to 400 ˚F)
Dual independent outputs -LHT -270 ˚C to 200 ˚C (-454 ˚F to 400 ˚F)
Connectors to interface to nearly any brand of test equipment
50 mm gauge length
links.
Diameter Range
• Self-supporting on the specimen. METRIC Circumferential Measuring Range
• May be used simultaneously with Model 3542RA axial extensometers. -100M 50 mm to 100 mm METRIC
-150M 50 mm to 150 mm -020M +2.0 mm
• Versions available for use in tri-axial confining pressure cells, at high -200M 50 mm to 200 mm -030M +3.0 mm
pressures and temperatures.
-060M +6.0 mm
U.S.A.
• Includes the Epsilon Shunt Calibration System for on-site electrical -120M +12.0 mm
-0400 2.00” to 4.00”
calibration. -0600 2.00” to 6.00” U.S.A.
• Rugged, dual flexure design for strength and improved performance. -0800 2.00” to 8.00” -080T +0.080”
• Includes high quality foam lined case. -125T +0.125”
-250T +0.250”
-500T +0.500”
Specifications
CERTIFIED
Visit our website at www.epsilontech.com
Contact us for your special testing requirements.
Model 3544
Used with Model 3542RA dual averaging extensometer.
• Includes the Epsilon Shunt Calibration System for on-site electrical METRIC
1
calibration. -070M 70 mm
-076M 76 mm
• Rugged, dual flexure design for improved performance. -100M 100 mm
• Includes high quality foam lined case.
U.S.A.
1
-0275 2.75”
Specifications -0300 3.00”
-0400 4.00”
Measuring Range: ±0.5 mm or ±0.020 inches
Excitation:
5 to 10 VDC recommended, 12 VDC or VAC max..
Output:2 to 4 mV/V nominal, depending on model
•
Linearity:
≤0.20% of full scale measuring range, depending
on model Model Number 3909- __ __ __ __
Temperature Range: Standard is -40 °C to +100 °C (-40 °F to +210 °F)
1 Special order.
Cable: Integral, flexible Teflon® cable, 2.5 m (8 ft) standard
Operating Force: <30 g typical Example: 3909-0300: 3.00 inch gauge length with a
full scale measuring range of ±0.020 inches
Options
Adjustable fixture for gluing gauge points to test samples (recommended) - adjustable for
offset height and gauge length; configurable for various specimen diameters and mounting Visit our website at www.epsilontech.com
gauge points at 90°, 120°, and 180° Contact us for your special testing requirements.
Gauge length adapters
Connectors to interface to nearly any brand of test equipment
CERTIFIED
3” gauge length
3/20/12
Epsilon Technology Corp.
Jackson, WY, USA
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION
inch 3/20/12
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED SIZE
A SCALE SHEET
1 OF 1
Epsilon Technology Corp.
Jackson, WY, USA
73
at substantial savings.
MODEL 3910 Extensometers for Creep Compliance and Tensile Strength Testing of Asphalt
Designed for asphalt core testing applications with core samples
having 100 and 150 mm (4 and 6 inch) diameters. The unit meets
1” gauge length
•
Specifications
Model Number 3911- __ __ __ __
Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max.
Output: 2 to 4 mV/V nominal, depending on the model Example: 3911-150M: +1.50 mm measuring range
Linearity: ≤0.20% of full scale measuring range, depending
on model
Temperature Range: Standard is -40 °C to +100 °C (-40 °F to +210 °F)
Visit our website at www.epsilontech.com
Cable: Integral, ultra-flexible cable, 2.5 m (8 ft) standard
Contact us for your special testing requirements.
Specimen Size: Adjustable to fit both 100 mm and 150 mm (4 inch and 6 inch)
diameter specimens
Options
CERTIFIED
samples. The units are designed to be used in conjunction with the Model
81
MODEL 3442AVG Averaging Axial Extensometers
This all-purpose averaging axial extensometer is used in tension
METRIC METRIC
• Measures average strain in both tension and compression, and can be used
-010M 10.0 mm -005M ±0.50 mm
for cyclic testing.
-0125M 12.5 mm -010M ±1.00 mm
• Measures opposite sides of the specimen to average out misalignment. -025M 25.0 mm -025M +2.50 mm/-1.00 mm
-050M 50.0 mm
• When configured with separate strain outputs, can be used to calculate U.S.A.
average strain and % bending. U.S.A. -002T ±0.020”
• Knife edge mounting allows mounting on round or flat specimens - much -0050 0.500” -005T ±0.050”
-0100 1.000” -010T +0.100”/-0.050”
easier to mount than designs using conical points, especially on thin flat
-0200 2.000”
specimens and round specimens.
• All models have mechanical overtravel stops in both directions. Hardened
tool steel knife edges are easily replaced. A spare set comes with every
extensometer. • •
• Includes the Epsilon Shunt Calibration System for on-site electrical Model Number 3442AVG - __ __ __ __ - __ __ __ __ - __ __
calibration. •
• Rugged, dual flexure design for strength and improved performance. Much
stronger than single flexure designs, this also allows cyclic testing at Temperature Range
higher frequencies.
-LT -270 ˚C to 100 ˚C (-454 ˚F to 210 ˚F)
• Includes high quality foam lined case and spare set of tool steel knife -ST -40 ˚C to 100 ˚C (-40 ˚F to 210 ˚F)
edges. -HT1 -40 ˚C to 150 ˚C (-40 ˚F to 300 ˚F)
-HT2 -40 ˚C to 200 ˚C (-40 ˚F to 400 ˚F)
-LHT -270 ˚C to 200 ˚C (-454 ˚F to 400 ˚F)
Specifications
Options
50 mm Gauge Length
CERTIFIED
25 mm Gauge Length
The Model 3560-BIA uses a design unique to Epsilon, where the knife edges
remain parallel during the displacement. This approach greatly reduces crosstalk
between axes and allows use on round or flat specimens with equal ease. These
extensometers are very easy to mount. Integral springs hold the unit on the test
sample. The parallel multiple flexure design makes these units very durable.
The Model 3560-BIA extensometers are strain gaged devices, making them
compatible with any electronics designed for strain gaged transducers. Most
often they are connected to a test machine controller with electronics for a strain
channel, and Epsilon will equip the extensometer with compatible connectors that
are wired to plug directly into the controller. For systems lacking the required
electronics, Epsilon can provide a variety of signal conditioning solutions that
enable connecting to data acquisition systems or other equipment. The standard
model 3560-BIA configuration requires two strain channels in the testing machine.
The optional configuration requires three strain channels in the testing machine.
For customers who only need to measure modulus and do not need to measure
Poisson’s ratio, Epsilon recommends the smaller, lighter, fatigue test rated model
3442AVG.
See the electronics section of this catalog for available signal conditioners and
strain meters.
84 Visit our website at www.epsilontech.com
Features Ordering Information
• May be left on through failure with composites that fail progressively (non- Model 3560-BIA Available Versions: ANY combination of gauge length, measuring
range and temperature range listed below is available.
explosive) and low-elongation materials.
• Multiple sets of dual flexures and mechanical stops allow testing through
Gauge Length
failure and provide a rugged unit.
METRIC
• Full bridge, 350 ohm strain gaged design for compatibility with nearly any -010M
1
10.0 mm Measuring Range
test system. -025M 25.0 mm
2 % AXIAL STRAIN TRANSVERSE
• Includes the Epsilon Shunt Calibration System for on-site electrical -050M 50.0 mm MEASURING RANGE
3
calibration. -005 ±5% ±1.0 mm (±0.050”)
U.S.A. 3
1
-010 ±10% ±1.0 mm (±0.050”)
• Rugged, dual flexure design for improved performance. -0050 0.500”
-0100 1.000”
• Knife edge mounting and parallel displacement allows mounting on round 2
-0200 2.000”
or flat specimens. Much easier to mount than designs using conical points
(especially on thin flat specimens and round ones).
• Self-supporting on the specimen.
• •
• High accuracy and minimal crosstalk between channels. Model Number 3560-BIA - __ __ __ __ - __ __ __ - __ __
• Includes high quality foam lined case and spare set of tool steel knife •
edges.
Excitation:
5 to 10 VDC recommended, 12 VDC or VAC max.
-LT -270 ˚C to 100 ˚C (-454 ˚F to 210 ˚F)
-ST -40 ˚C to 100 ˚C (-40 ˚F to 210 ˚F)
Output:2 to 4 mV/V, depending on model
-HT1 -40 ˚C to 150 ˚C (-40 ˚F to 300 ˚F)
Accuracy:Standard configurations meet ASTM E83 class B-1 and ISO 9513
class 0,5 requirements for accuracy in the axial direction. A test -HT2 -40 ˚C to 200 ˚C (-40 ˚F to 400 ˚F)
certificate is included. All standard units have linearity of 0.15% full -LHT -270 ˚C to 200 ˚C (-454 ˚F to 400 ˚F)
scale measuring range or better in the transverse direction.
Linearity: ≤0.15% of full scale measuring range, depending on model 1 1 0 mm and 0.5 inch gauge lengths are only available in 10% axial measuring ranges.
Temperature Range: Standard (-ST) is -40 °C to +100 °C (-40 °F to 210 °F) 2 50 mm and 2.0 inch gauge lengths are only available in 5% axial measuring ranges.
3 If the gauge length is ordered in mm units, then the transverse measuring range will be in mm. If the gauge
Optional (-LHT) is -270 °C to +200 °C (-454 °F to 400 °F)
length is ordered in inch units, then the transverse measuring range will be in inches.
Cable: Integral, ultra-flexible cable, 2.5 m (8 ft) standard
Note: model 3560-AVG has been replaced by the smaller, fatigue test rated model 3442AVG .
Specimen Size: Works with samples 2.5 to 25 mm (0.1 to 1 inch) width or up to 15
mm (0.6 inch) diameter Example: 3560-BIA-050M-010-HT2: 50.0 mm gauge length, ±10% axial strain
Operating Force: 30 to 50 g typical measuring range/±1.0 mm transverse measuring range, HT2 option (-40 °C to 200 °C)
Crosstalk: Less than 0.5% MODEL
Bi-Axial
Options
2.50° φφ10°
γ γ2.50° 10°
CERTIFIED
Torsional Shear
Model Number Axial Gauge Length Axial Strain Strain Angle
3550-025M-005-002-ST 25 mm ±5% ±2°
3550-025M-005-003-ST 25 mm ±5% ±3°
Visit our website at www.epsilontech.com
3550-025M-010-002-ST 25 mm ±10% ±2°
Contact us for your special testing requirements.
3550-0100-010-002-ST 1 inch ±10% ±2°
-ST temperature range is -40 °C to 100 °C (-40 °F to 210 °F), but -HT1, -HT2, -LT,
and -LHT options are also available. This unit is built to order; contact Epsilon for a
unit specific to your testing requirements.
with low noise. Easily interfaced to test controllers, data acquisition boards and chart γγ φφ
recorders. gth
en th
e l ng
ugge le The shear strain is related to the angle of
• Includes high speed analog and digital outputs. a
h gau
nc g twist (a commonly referenced parameter
0 i ch
• Web-based user interface for setup and data acquisition. γ 1.0.00 in φ
1
gth
in torsion testing), φ, by the following
• Selectable analog and digital filter options from 2 Hz to 3 kHz. ug
el
en
relationship:
a
R.500 hg
nc
• Built-in calibration reference and auto-zero features. R.500
1.0
0i
1-inch diameter
1-inch diameter
specimen
• Multiple extensometer calibration files may be loaded for use with one controller. specimen
R.500
• Can be used with specimens at elevated temperatures while only requiring room dφ
1-inch diameter γ = R1
temperature calibration. specimen dL 1
Options
• All models can measure in both tension and compression and may be used Requires external mounting brackets and 110 - 240VAC / 4W electrical power.
for cyclic testing at test frequencies up to 10 Hz. Liquid cooling is recommended; required for 800 °C and above.
• Ships fully calibrated with calibration that is traceable to NPL; voltage Other configurations are available with special order; please contact Epsilon to discuss your requirements.
output may be user-specified (typically 0-10V).
• Excellent ambient vibration rejection; primary vibration mode >100 Hz
Gauge Length (X & Y)1 Measuring Range (X & Y)1
typical
METRIC METRIC
• Digital controller and power supply included. Provides high level DC -0125M 12.5 mm -015M +1.5 mm / -1.5 mm
voltage output with low noise. Easily interfaced to test controllers, data -025M 25.0 mm -020M +2.0 mm / -1.0 mm
acquisition boards and chart recorders. -025M +2.5 mm / -0.5 mm
U.S.A.
• Includes high speed analog and digital outputs. -0050 0.500”
U.S.A.
• Web-based user interface for setup and data acquisition. -0100 1.000”
-060T +0.060” / -0.060”
• Selectable analog and digital filter options from 2 Hz to 3 kHz. -080T +0.080” / -0.040”
-100T +0.100” / -0.020”
• Built-in calibration reference and auto-zero features.
• ultiple extensometer calibration files may be loaded for use with one
M
controller. • •
• Can be used with specimens at elevated temperatures while only requiring Model Number 7651- __ __ __ __ - __ __ __ __ - __ __
room temperature calibration. •
• Quick-disconnect water cooling fittings and signal cables.
Temperature Range
• Includes high quality foam lined case and a spare set of rods.
-ST Room temperature to 1200 °C (2200 °F)
Specifications -HT Room temperature to 1600 °C (2900 °F)
Analog Output: User specified, ±10VDC typical, ±10.8 VDC rail 1 Consult factory for applications requiring different X and Y gauge lengths or
Digital Output: 24 bit high speed Ethernet output with built-in web interface measuring ranges.
Cyclic Testing: Up to 10 Hz, depending on test system and test amplitude Example: 7651-025M-020M-ST: 25 mm gauge length,
Accuracy: Standard configurations meet ASTM E83 class B-1 and ISO 9513 class +2.0 / -1.0 mm measuring range, standard temperature
0,5 requirements for accuracy. A test certificate is included. range (room temperature to 1200 °C)
Linearity: 11 point digital linearization, ≤0.1% FS typical linearity
Hysteresis: ≤0.1% FS typical
Crosstalk: none Visit our website at www.epsilontech.com
Resolution: <75 PPM (0.0075%FS) RMS @ 4 kHz, < 6PPM (0.0006%FS) @ 100 Hz Contact us for your special testing requirements.
at gauge length
Filter: Selectable 100 Hz analog and 2 Hz - 3 kHz digital filters
Temperature Range: Standard (-ST) is to 1200 °C (2200 °F), optional
(-HT) 1600 °C (2900 °F)
Sensor Cables: 2 m (6.5 ft) room temperature cables CERTIFIED
Output Cables: Flexible 2.4 m (8 ft) analog output cables
Coolant Interface: Two barbed hose fittings for 1/8” (3.2 mm) ID coolant hoses
Specimen Size: Fits any flat cruciform or axial-only test specimen with a test area
larger than the extensometer GL
Operating Force: <30 grams typical
Contact Force: <560 grams typical
Environment: Recommended for testing in dry air, inert / non-corrosive gases, or
vacuum
Power: Includes power supply
Options
High temperature option (-HT suffix) for use to 1600 °C
Load frame mounting brackets
Bulkhead adapters for use in vacuum chambers
Model EPS170 constant-temperature recirculating chiller - see the Options tab on the web
page for important details about liquid cooling requirements
Connectors to interface to nearly any brand of test equipment
MODEL 7651 EXAMPLE
EPSILON TECH–World class quality
91
at substantial savings.
92
MODEL 3565-xxxx-xx
Bolt Extensometer
MODEL 4013
KGR Extensometer
3567 Catalog
MATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION [mm] SIZE
3567
SCALE DATE SHEET
URE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
inch A 1:2 6/25/2015 1 OF 1
MODEL 4030
Submersible Axial Extensometer
3421 Sandwich Core Shear and Rigid Cellular Plastic Shear Testing Extensometers
CAT-3421
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION [mm] SIZE
CAT-3421
SCALE DATE SHEET
0
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
inch A 1:1 6/30/2016 1 OF 1
93
MODEL 3565 Bolt Extensometers for Proof Load Testing
Designed for measuring small measuring strain ranges as required
for proof load testing of bolts and similar applications such as yield
measurement.
The Model 3565 uses hard conical points to contact the bolt at
the center of the head and at the bottom. It is fully adjustable
for different length bolts ranging from 25 mm (1 inch) in
length to 150 mm (6 inches) standard. Extension beams are
available for longer bolts. The standard maximum measuring
range is 1.25 mm (0.05 inches). Generally, on longer bolts this
extensometer will be self-supported without requiring any
Model 3565 extensometer for
bolt proof load testing centering marks or punch marks on the bolt. For shorter bolts
these marks may be required. If the conical pins are sharp,
marks are often not needed even on the shortest bolts.
Gauge length may be set to any length The extensometer has a zero adjustment screw to adjust the length between
by sliding, locking, and fine-adjusting the contact pins. This is used to set the output voltage to zero, which corresponds
the lower arm
to the correct starting position for the test. It also includes a breakaway lower
arm. In the event a bolt should fail, the breakaway arm snaps free, helping to
prevent damage to the extensometer. This is easily re-installed. In the event that
bolt failures are likely during a test, it is recommended the user attach a cord
around the upper part of the beam and tie the other end to the test frame to
prevent the extensometer from falling. The conical point contacts included with
the extensometer are made from tungsten carbide.
The Model 3565 extensometers are strain gaged devices, making them
compatible with any electronics designed for strain gaged transducers. Most often
they are connected to a test machine controller. The signal conditioning electron
ics for the extensometer is typically included with the test machine controller or
may often be added. In this case the extensometer is shipped with the proper
connector and wiring to plug directly into the electronics. For systems lacking
the required electronics, Epsilon can provide a variety of solutions, allowing the
Gauge length adapters may be added
for longer fasteners. extensometer output to be connected to data acquisition boards, chart recorders
or other equipment.
See the electronics section of this catalog for available signal conditioners and
strain meters.
failure. METRIC
-125M +1.25 mm
• Self-supporting on the bolt specimen typically without the need for
centering or punch marks. U.S.A.
-050T +0.050”
• Includes the Epsilon Shunt Calibration System for on-site electrical
calibration.
• Rugged, dual flexure design for improved performance. •
Model Number 3565- __ __ __ __ - __ __
• Includes high quality foam lined case.
Model Number 3565E- __ __ __ __ - __ __
Model 3565: throat depth up to 56.4 mm (2.22 inches) •
Specifications Model 3565E: throat depth up to 97.8 mm (3.85 inches)
CERTIFIED
97.8
56.4 3.85
2.22
46 87.3
1.812 3.44
and sleeve assemblies. Use for tension, cyclic, slip, and differential
elongation tests.
Options
Gauge length adapters may be added for gauge lengths over 675 mm (26.6 inches) to
extend the maximum gauge length to 975 mm (38.4 inches)
Collars for 6 – 14 mm (#2 - #4) and 32 – 60 mm (#10 - #18J) diameter rebar are optional;
collars for 8 – 36 mm (#3 – #11) diameter rebar are included standard
Average of two or three separate measurements
Average output at a single connector, or separate outputs and connectors for each
measurement to enable subsequent averaging
Connectors to interface to nearly any brand of test equipment
CERTIFIED
Epsilon Technol
Jackson, WY,
97
DWG. NO.
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION [mm] SIZE
3567
SCALE DATE
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
inch A 1:2 6/25/201
MODEL 4013 Averaging Extensometers for ASTM D5656 Adhesive Lap Shear Tests
Designed specifically for performing tests in accordance with ASTM
sides of the test specimen and the output is an average of the two
readings.
Specifications
•
Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max. Model Number 4013-__ __ __ __ - __ __
Output: 2 to 4 mV/V nominal, depending on model •
Linearity: ≤0.20% of full scale measuring range, depending
on model
Temperature Range
Temperature Range: Standard (-ST) is -40 °C to +100 °C (-40 °F to 210 °F)
Optional (-LHT) is -270 °C to +200 °C (-454 °F to 400 °F) -LT -270 ˚C to 100 ˚C (-454 ˚F to 210 ˚F)
Cable: Integral, ultra-flexible cable, 2.5 m (8 ft) standard -ST -40 ˚C to 100 ˚C (-40 ˚F to 210 ˚F)
-HT1 -40 ˚C to 150 ˚C (-40 ˚F to 300 ˚F)
Options -HT2 -40 ˚C to 200 ˚C (-40 ˚F to 400 ˚F)
-LHT -270 ˚C to 200 ˚C (-454 ˚F to 400 ˚F)
Option for independent left and right measurement outputs (two connectors - requires two
strain channels) Example: 4013-005M-ST: 0.5 mm measuring range, standard
Connectors to interface to nearly any brand of test equipment temperature range (-40 °C to 100 °C)
CERTIFIED
Visit our website at www.epsilontech.com
Contact us for your special testing requirements.
Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max. -LT -270 ˚C to 100 ˚C (-454 ˚F to 210 ˚F)
Output: 2 to 4 mV/V -ST -40 ˚C to 100 ˚C (-40 ˚F to 210 ˚F)
Accuracy: ±5.0 mm/±0.200” measuring ranges: -HT1 -40 ˚C to 150 ˚C (-40 ˚F to 300 ˚F)
≤0.003 mm for displacement values <0.3 mm -HT2 -40 ˚C to 200 ˚C (-40 ˚F to 400˚˚F)
≤1.0% of reading for displacement values ≥0.3 mm
-LHT -270 ˚C to 200 ˚C (-454 ˚F to 400 ˚F)
±2.5 mm/±0.100” measuring ranges:
≤0.0015 mm for displacement values <0.3 mm Example: 3421-050M-ST: ±5.0 mm measuring range, standard
≤0.5% of reading for displacement values ≥0.3 mm
temperature range (-40 °C to 100 °C)
Temperature Range: Standard (-ST) is -40 °C to +100 °C (-40 °F to 210 °F)
Optional (-LHT) is -270 °C to +200 °C (-454°F to 400 °F)
Cable: Integral, ultra-flexible cable, 2.5 m (8 ft) standard
Specimen Size:
Thickness (including core and both loading plates): 20-75 mm Visit our website at www.epsilontech.com
Contact us for your special testing requirements.
(0.8–3.0 inches); width: 40 mm (1.5 inch) minimum, 50-150 mm
(2-6 inches) typical
Options
Connectors to interface to nearly any brand of test equipment
CERTIFIED
CAT-3421
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EPSILON TECHNOLOGY CORP. ANY REPRODUCTION [mm] SIZE
CAT-3421
SCALE DATE SHEET
0
OR DISCLOSURE IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF EPSILON TECHNOLOGY CORP. IS PROHIBITED
inch A 1:1 6/30/2016 1 OF 1
construction.
Specifications
CERTIFIED
Customized Sometimes the test requires a customized version of one of our extensometers or COD gages. If you have
special requirements and do not see it in our catalog, please contact us to discuss your application.
Extensometers
3561 Biaxial
Custom biaxial extensometer for plane strain measurement in sheet metal testing. This unique design contacts the
test sample from one side only, as needed for a very wide sample. Used for formability testing.
Bulge Test
Special biaxial extensometer for limiting dome height bulge tester for sheet metal formability testing.
Simultaneous X and Y strain measurements are taken.
104104
3640
High temperature 540 °C (1000 °F)
capacitive based deflectometer.
The model shown has 1 inch of
measuring range.
Wear-Resistant Carbide
Knife Edges
PART NO. 9903-05-02
Designed as an alternative for Knife Edges for Notch-Sensitive
customers who experience Materials
STRAIGHT VEE CONICAL
slipping or regularly wear PART NO. 350210V2-01
CHISEL CHISEL CHISEL
out the standard knife edges when testing hard The dual-bevel design and robust
metals and ceramics, these ultra-hard, dual-bevel tool steel construction of these knife
knife edges will retain a sharp edge and last much edges make them an ideal choice for applications
longer. They are extremely sharp and not suitable for that tend to cause chipping damage to standard or
specimens that are sensitive to stress concentrations wear-resistant knife edges at failure. As they are not
such as soft plastics. as sharp as their counterparts, these knife edges are
also well-suited for working with notch-sensitive
Vee Knife Edges applications.
PART NO. 9903-01-01
Extended Knife Edges
Designed for use on round
PART NO. 350210EXT-01
Available Ceramic Rod Tip Styles specimens, these knife edges
Knife edges for applications where
will self-center the extensometer
the additional length is required,
on the specimen. Due to the
Specify rod tip style desired. such as where the grips are very
contact point variation that can
close together. Only available by special order.
Straight chisel tips are the most versatile, since occur between specimens of different diameters, units
they can be used with round or flat specimens. Requires recalibration when retrofitting an existing
with these knife edges must be calibrated with posts
extensometer.
of equal diameter. On extensometers with longer arms,
errors created by this variation are not so pronounced, Ceramic Knife Edges
but on units with shorter arms lengths, this must be PART NO. 350210C2-01
taken into consideration. These knife edges are typically
used in low cycle fatigue
Corrosion-Resistant Stainless applications on hard metals
Steel Knife Edges where metallic knife edges would
PART NO. 350210-02 likely experience undue wear.
These hardened knife edges They are also used on the submersible Model 4030
are designed to be used in extensometer to prevent galvanic corrosion between
environments where corrosion the extensometer and the test specimen.
resistance is required. Primary
applications are in biomedical testing where the knife Bolt-On Knife Edges for Fracture
edges may be exposed to saline solutions. Mechanics
PART NO. BOLT-ON KNIFE EDGES
Rounded Knife Edges Reusable bolt-on knife edges for
PART NO. 350210-BLUNT attaching COD gages to fracture
Knife edges designed for use mechanics and fatigue crack growth
on transverse extensometers specimens. Sold in sets of two. 30° knife edge angle.
and applications where blunt Made of nickel-plated tool steel. Rated to 500 °C.
edges are required. These are
primarily used on transverse extensometers such as
model 3575.
106106
EXTENSOMETER
NOTES
107
108
SGA Analog Signal Conditioners
109
MODEL SGA Analog Signal Conditioners
The SGA series signal conditioners are ideal for cyclic and high
Specifications
Zero Adjustment
Knob(s): On front panel. Fine (±5% FS) and coarse. (±80% FS) adjustment ranges
Model SGA dual channel Model SGA dual channel
signal conditioner rear panel Selectable
Output Ranges: ±5V, ±10V*, 0-10V, 0-20 mA, etc.
Bridge Excitation: 5V or 10V* DC
Bridge Sensitivity
Range: 0.06 to 30.0 mV/V
Linearity: 0.03% FS typical
Filtering: 8 settings, 1-5000 Hz, plus secondary 800 Hz filter. 1 kHz* default
Operating
Temperature Range: -10 to +50 °C
Zero Temperature
Coefficient: 0.009%/C (90 ppm/°C)
90 Day Output
Stability: ~330 ppm
Output Noise: 10-100 µV (1-100 ppm), depending on filter, DAQ, and gain. 50 µV typical
Input Power: 100-240 VAC, 50-60 Hz. Specify regional power plug type required. Includes: power supply,
connection for extensometer(s), output cable(s) and calibration with extensometer
*default setting
Specifications
CERTIFIED
NOTES
NOTES
115
MODEL 3590VHR Very High Resolution Digital Electronic Calibrators
Epsilon’s very high resolution calibrator features 20 nanometers
requirements for ASTM E83 Class B-1 for extensometers with gauge
lengths ≥6 mm, and meets ISO 9513 Class 0,5, both over the full
Supplied with
ISO 17025 accredited
calibration
Features
• 0.001 mm (50 microinches) resolution
• ±0.004 mm/25 mm (±0.00015 in/in) accuracy
• Full 50 mm (2 inches) axial measuring range
The 3590AT can be converted into a standard Model 3590 calibrator with the optional
3590AT-3590 adapter.
CERTIFIED
NOTES
121
122
Calibration References
ESCS Epsilon Shunt Calibration System
VREF Modules
123
MODEL ESCS Epsilon Shunt Calibration System
Designed to allow Epsilon’s extensometer calibration to be easily
Epsilon Shunt The second point is the shunt calibration point. When the Epsilon Shunt is plugged into the Shunt
Connector, the shunt resistor, which is located in the Shunt Connector, is electrically connected
Calibration System across one arm of the extensometer’s Wheatstone bridge. The result is that the extensometer’s
output is electrically set to a known calibration point without having to mechanically displace
the extensometer’s arms. The known calibration point is shown on the extensometer’s Test
Certificate as the Shunted Reading, which was set at Epsilon using traceable mechanical
calibrators and an accredited ISO 17025 calibration process.
To complete the shunt calibration, the signal conditioning electronics or software are adjusted
so that the extensometer’s readout matches the Shunted Reading shown on the extensometer’s
Test Certificate.
Using the Epsilon Shunt Calibration System is a
simple two-step process.
1. Set the extensometer to its gauge length and zero its
output. This sets point 1 in the example graph.
2. Plug the Epsilon Shunt into the Shunt Connector
and adjust the signal conditioning electronics or
software so that the extensometer’s readout matches
the Shunted Reading on the extensometer’s Test
Certificate. This sets point 2 in the example graph.
CERTIFIED
The proven compliance with these standards demonstrates the accuracy and
to quality.
ensured that the uncertainty in our measurements is both documented and reduced
to the lowest amount possible. During the accreditation process, the robustness of
tat i o n
better track ways to improve our products and services and
re d i
continue to provide our customers with products to fulfill their
acc quality
materials testing needs.
accuracy
Our certificates and scope of accreditation can be viewed on
certifications.
127
1. Limited Warranty
Epsilon warrants all products of our manufacture (“Products”) to be free of defects in materials or
workmanship for a period of one year from date of shipment. This warranty covers both parts and labor.
Epsilon reserves the right to determine if defects are covered by warranty. This warranty does not cover
items subject to wear. Specifically, this does not cover knife edges or ceramic rods. Upon return of item
(shipping prepaid) for repair, Epsilon will determine whether the item is covered by warranty, and repair or
replace it at our option.
Epsilon Tech:
Our Warranty The warranty period for any product is not extended from its original date by virtue of having been repaired
or replaced under the original warranty.
2. Other Limits
THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. Epsilon does not warrant against damages or defects arising out of improper or abnormal use or
handling of the Products, against defects or damages arising from improper installation (where installation
is by persons other than Epsilon), against defects in products or components not manufactured by Epsilon,
or against damages resulting from such non-Epsilon made products or components. Epsilon passes on
to Buyer the warranty it received (if any) from the maker thereof of such non-Epsilon made products or
components. This warranty also does not apply to Products which have been repaired or disassembled by
any person who is not authorized in writing by Epsilon.
3. Exclusive Obligation
THIS WARRANTY IS EXCLUSIVE. The sole and exclusive obligation of Epsilon shall be to repair or replace
the defective products in the manner and for the period provided above. Epsilon shall not have any other
obligation with respect to the products or any part thereof, whether based on contract, tort, strict liability or
otherwise. Under no circumstances, whether based on this Limited Warranty or otherwise, shall Epsilon be
liable for incidental, special, or consequential damages.
4. Other Statements
Epsilon’s employees or representatives’ ORAL OR OTHER WRITTEN STATEMENTS DO NOT CONSTITUTE
WARRANTIES, shall not be relied upon by Buyer, and are not a part of the contract for sale or this limited
warranty, unless agreed to in writing by a corporate officer of Epsilon.
5. Entire Obligation
This Limited Warranty states the entire obligation of Epsilon with respect to the Products. If any part of this
Limited Warranty is determined to be void or illegal, the remainder shall remain in full force and effect.