0% found this document useful (0 votes)
45 views12 pages

SKM HMAH

The HMAH/HMAH-1 Series by S.K.M Air Conditioning LLC offers Hygienic Modular Air Handling Units with airflow ranges from 1000 cfm to 42500 cfm, suitable for environments requiring high cleanliness standards such as hospitals and laboratories. The units are certified by Eurovent and TÜV SÜD, ensuring compliance with various hygiene and performance standards. The certificate is valid until September 30, 2023, and confirms that the products meet the necessary requirements for hygienic design and functionality.

Uploaded by

Ahmed Mohamed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
45 views12 pages

SKM HMAH

The HMAH/HMAH-1 Series by S.K.M Air Conditioning LLC offers Hygienic Modular Air Handling Units with airflow ranges from 1000 cfm to 42500 cfm, suitable for environments requiring high cleanliness standards such as hospitals and laboratories. The units are certified by Eurovent and TÜV SÜD, ensuring compliance with various hygiene and performance standards. The certificate is valid until September 30, 2023, and confirms that the products meet the necessary requirements for hygienic design and functionality.

Uploaded by

Ahmed Mohamed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

HMAH / HMAH-1 Series

Hygienic Modular Air Handling Units

Range 1000 cfm to 42500


cfm (472 l/s to 20058 l/s)

S.K.M Air Conditioning LLC


1
CERTIFICATE
N° 15.05.004
Air Handling Unit / Centrales de traitement d'air
Range Name / Nom de Gamme :
HMAH
Granted on May 12, 2015 - Date 1ère admission 12 mai 2015

This document is valid at the date of issue - Check the current validity on:
Document valable à la date d’émission - Vérifier la validité en cours sur :
www.eurovent-certification.com

Participant/Titulaire
SKM Air Conditioning Equipment LLC
Industrial Area 13 - PO Box 6004
Sharjah, United Arab Emirates

This product performance certificate is issued by Eurovent Ce certificat de performance produit est délivré par Eurovent Certita
Certita Certification according to the certification rules: Certification dans les conditions fixées par le référentiel :

ECP AHU - « Air Handling Unit » in force at established ECP AHU – « Centrales de traitement d'air » en vigueur à date
date. d’édition.

Pursuant to the decision notified by Eurovent Certita En vertu de la décision notifiée par Eurovent Certita Certification, le
Certification, the right to use the mark ECP shall be granted to droit d'usage de la marque ECP, est accordé à la société qui en est
the beneficiary company for the above Range in the conditions bénéficiaire pour la gamme visée ci-dessus, dans les conditions
defined by the certification program mentioned. définies par le programme de certification mentionné.

Unless withdrawn or suspended, this certificate remains valid Sauf retrait ou suspension, ce certificat demeure valide tant que les
as long as the requirements for the certification program conditions du référentiel du programme de certification sont
framework are met. The validity of the certificate is to be respectées. La validité du certificat est à vérifier sur le site Internet
verified on www.eurovent-certification.com www.eurovent-certification.com

THIS CERTIFICATE HAS BEEN ISSUED ON 24/08/2022 CE CERTIFICAT A ÉTÉ EMIS LE 24/08/2022
THIS CERTIFICATE IS VALID UNTIL 30/09/2023 CE CERTIFICAT EST VALIDE JUSQU’AU 30/09/2023

Paris, 24 août 2022


Organisme accrédité n° 5-0517 Certification Produits et
Services selon la norme NF EN ISO/CEI 17065:2012
Portée disponible sur www.cofrac.fr
Accreditation #5-0517 Products and Services Certification MANAGING BOARD MEMBER / MEMBRE DIRECTOIRE
according to NF EN ISO/CEI 17065:2012 –
Scope available on www.cofrac.fr

COFRAC est signataire des accords MLA d’EA et MLA


d’IAF,
COFRAC is signatory of EA MLA and IAF MLA,
list of EA members is available on
www.european-accreditation.org/ea-members
list of IAF members is available on
www.iaf.nu//articles/IAF_MEMBERS_SIGNATORIES/4

1/2
EUROVENT CERTITA CERTIFICATION SAS au capital de 100 000 € - 48-50 rue de la Victoire 75009 Paris - FRANCE
Tel. : 33 (0)1 75 44 71 71 - 513 133 637 RCS Paris - SIRET 513 133 637 000 35 - TVA FR 59513133637
S06D06 TEMPLATE_ECP_RANGE_REV1.1
Herewith it is confirmed to the company

S.K.M Air Conditioning LLC


in
Sharjah – United Arab Emirates

based on the positive results of the tests on the

Air handling unit in hygienic design


AHU Range: “HMAH”
according to the standard
VDI 6022 part 1: 2018-01
VDI 3803 part 1: 2020-05
DIN 1946 part 4: 2018-09
DIN EN 13053: 2020-05

that the requirements of the Certification Program of the


TÜV SÜD Industrie Service GmbH are fulfilled.

The manufacturer is allowed to use the following


TÜV SÜD Certification Mark.

This certificate is valid until 2024-06-30

Certificate Registration Number: 13/21/51 (Revision 03)

______________________
Certification Body for Products
Refrigeration and Air-Conditioning
Munich, 2022-06-13

TÜV SÜD INDUSTRIE SERVICE GMBH, WESTENDSTRASSE 199, D-80686 MÜNCHEN


[email protected]
Herewith it is confirmed to the company

S.K.M Air Conditioning LLC


in
Sharjah – United Arab Emirates

based on the positive results of the tests on the

Air handling unit in hygienic design


AHU Range: “HMAH-1”
according to the standard
VDI 6022 part 1: 2018-01
VDI 3803 part 1: 2020-05
DIN EN 13053: 2020-05

that the requirements of the Certification Program of the


TÜV SÜD Industrie Service GmbH are fulfilled.

The manufacturer is allowed to use the following


TÜV SÜD Certification Mark.

This certificate is valid until 2024-06-30

Certificate Registration Number: 19/21/77 (Revision 02)

______________________
Certification Body for Products
Refrigeration and Air-Conditioning
Munich, 2022-06-13

TÜV SÜD INDUSTRIE SERVICE GMBH, WESTENDSTRASSE 199, D-80686 MÜNCHEN


[email protected]
Contents
,QWURGXFWLRQ..........................................5 Component Features ...........................6 Introduction
1RPHQFODWXUH......................................5 Major Sections and Sub Assemblies..7
General Features..................................6 Dimensional Data.................................11 SKM Hygienic Modular Air handling units are
designed to a high engineering standard and
are ideal, where the requirements of clean
and hygiene air are mandatory, like hospitals,
pharmaceuticals, laboratories, food industry,
electronic facilities and clean room applications

HMAH & HMAH-1 Units are available in 16


models to deliver from 1000 cfm (472 l/s) to 42500
Nomenclature cfm (20058 l/s) QRPLQDO DLU ÀRZ UDWH DJDLQVW
total static pressure up to 8.0 inwg (2000 Pa).
SKM Hygienic Air Handling Units are based on Standard Module sizes.
+0$+ 8QLWV DUH WHVWHG DQG FHUWL¿HG E\ 789
68' *HUPDQ\ DFFRUGLQJ WR 9',  9',
',1(1DQG',1VWDQGDUGV
Series- 02 03 +0$+8QLWVDUHWHVWHGDQGFHUWL¿HGE\789
HMAH/HMAH-1 68'*HUPDQ\DFFRUGLQJWR',9',
DQG',1(1
Height in Module Width in Module
,QFOXGLQJ%DVH+HLJKW Mechanical characteristics & rating performances
02=750 mm DUH FHUWL¿HG  E\ (XRURYHQW DFFRUGLQJ WR WKH
 PP
03=1075 mm VWDQGDUGV(1DQG(1
03=1225 mm
04=1375 mm SKM HMAH & HMAH-1 Units are manufactured
04=1475 mm
05=1700 mm LQDIDFLOLW\UHJLVWHUHGWR,62PDQXIDFWXULQJ
05=1800 mm quality standards and Coil performances are
06=2000 mm FHUWL¿HGLQDFFRUGDQFHZLWK$+5,6WDQGDUG
06=2100 mm
07=2325 mm SKM Hygienic Modular Air Handling Units are
07=2400 mm
08=2575 mm another premium international quality product
08=2700 mm from SKM.
 PP
10=3250 mm 6.0 SURYLGHV TXDOL¿HG VHUYLFH DQG VWRFN RI
replacement parts in all major cities of the
11=3575 mm *&&FRXQWULHV(J\SW-RUGDQDQG3DNLVWDQ
12=3875 mm See back cover for details or call SKM.

SKM Air Conditioning LLC

SKM reserves the right to change, in part or in


ZKROHWKHVSHFL¿FDWLRQVRILWV$LU&RQGLWLRQLQJ
(TXLSPHQWDWDQ\WLPHLQRUGHUWRDGGWKHODWHVW
WHFKQRORJ\7KHUHIRUHWKHHQFORVHGLQIRUPDWLRQ
may change without any prior notice.
You name it.....We cool it.

S.K.M Air Conditioning LLC


5
Modular Air Handling Unit HMAH Series

General Features Panels


• Modular construction. • Panels shall be double skin construction with Polyurethane
•$SSOLFDWLRQÀH[LELOLW\ foam insulation sandwiched between the inner and outer
•3HUIHFW7KHUPDOEUHDN panels.
•1RPDWHULDOVWKDWFDXVHDWKUHDWWRKXPDQKHDOWK • ,QHMAH, panel thickness is 63 mm, powder coated hot-
• 1R0DWHULDOZKLFKIDFLOLWDWHVWKHJURZWKRIKDUPIXO GLSSHGJDOYDQLVHGVKHHW *, RXWHUVNLQVWDLQOHVVVWHHOLQQHU
microorganisms. skin for the complete unit.
• ,QWHUQDOVXUIDFHVRIWKHXQLWVDUHPDGHRIZHDUUHVLVWDQW • ,QHMAH-1, bottom panels are 63 mm thick and side & top
materials. SDQOHVDUHPPWKLFNSRZGHUFRDWHGKRWGLSSHG*,VKHHW
•(DV\IRUPDLQWHQDQFH outer skin, stainless steel inner skin for the bottom panel and
•(DV\IRUFOHDQLQJLQVLGHWKHXQLWVDQGLWVFRPSRQHQWV SRZGHUFRDWHGJDOYDQL]HGVKHHW *, IRUWRSDQGVLGHSDQHOV
• &RQIRUPLW\ZLWKDSSOLFDEOH(XURSHDQKHDOWKDQGVDIHW\ • Access panels are provided for all sections to facilitate
standards. access to all internal components for maintenance and
cleaning.
A typical HMAH & HMAH-1 Unit consists of a wide choice of
•5HPRYDORIDQ\SDQHOVVKDOOQRWDႇHFWRQWKHVWUXFWXUDO 
a combination but not limited to the following sections, fan,
FRROLQJ FRLO KHDWLQJ FRLO KXPLGL¿HU ¿OWHU VHFWLRQ PL[LQJ ER[ integrity of the units.
with dampers, plenums etc.

Access Doors
• Suitable access doors are provided for all sections to facilitate
access to all components for maintenance and cleaning.
• Hinged access doors with Q turn handles with internal handles
  IRU IDQ VHFWLRQ +LQJHG RU OLIW Rႇ DFFHVV SDQHOV IRU DOO RWKHU
sections.
• 9LHZSRUWDORQJZLWKOLJKWDUHSURYLGHGXSVWUHDPWRWKH 
components for all access doors.

)LQLVK
•3RZGHUFRDWHG¿QLVKVWDQGDUG&RORXU5$/
Component Features
Casing & Construction Insulation
• All panels are internally insulated with polyurethane foam
Penta-Post Frame insulation with density of 2.5 lb/ft3 (40 kg/m3) and thermal
•([WUXGHG$OXPLQLXP3UR¿OHZLWKEXLOWLQWKHUPDOEUHDNV\VWHP FRQGXFWLYLW\RI%78LQIW)K (0.02 W/mK).
•$OXPLQLXPSUR¿OHVIUDPHVDUHMRLQHGE\PHDQVRIVWURQJQ\ORQ
corners.
*DVNHWV
• Specially designed closed cell gaskets liner between
WKHSDQHODQGIUDPHWRHQVXUHDQH[FHOOHQWOHDNWLJKWDQG
thermal bridge protection.
• Gaskets using in SKM Hygienic AHU are totally closed cell type,
and it will not help growth of bacteria or fungus, preventing
contamination.
•*DVNHWVFRPLQJFRQWDFWZLWKDLUÀRZDUHFHUWL¿HGDFFRUGLQJ
WR9',VWDQGDUGVDQGPDWHULDORIJDVNHWVDUHWHVWHGEDVHG
RQ,62VWDQGDUGLQORERUDWRLHVZKLFKDUHDFFUHGLGDWHG
)LJ$OXPLQXP3UR¿OHZLWKEXLOWLQWKHUPDOEUHDNV\VWHP
DFFRUGLQJWR(1VWDQGDUG

6
Base Frame and Floor Panel

• Painted Hot dip galvanised sheet metal or structural


steel base frame.
•3URYLVLRQIRUGUDLQDJHWKURXJKÀRRUSDQHOVIRUHDFKVHFWLRQ
can be provided on request.

Fig 3: Fan Section

Coil Section

•9DULHW\RIFRLOVLQFOXGLQJFKLOOHGZDWHUGLUHFWH[SDQVLRQDQG
hot water are available to meet a wide range of application
UHTXLUHPHQWV&RLOSHUIRUPDQFHDUHFHUWL¿HGLQDFFRUGDQFH
)LJ'UDLQDEOH)ORRU3DQHO ZLWK$+5,6WDQGDUG&RLOVDUHWHVWHGE\DLUSUHVVXUH 
(optional)
while coils are submerged in water to a pressure of 300 psig.
• Coils are constructed from seamless copper tubes. Aluminium
¿QVDUHSURYLGHGDVVWDQGDUG6WDLQOHVVVWHHOFRLOIUDPH
•0LQLPXP¿QVSHULQFKDQG0D[LPXP¿QVSHULQFK
• Coils can be provided with moisture eliminator depending on
WKHDLUFRQGLWLRQV6WDLQOHVVVWHHOHOLPLQDWRUIUDPH(OLPLQDWRU
0DMRUVHFWLRQVDQG6XE$VVHPEOLHV can be pulled out for cleaning.
• Stainless steel, double skin, insulated condensate drain pan
Fan Section • Drain pans are slopped from three sides for a complete
drainage.
• Direct driven centrifugal fans are supplied as standard in
HMAH.
• Direct driven fans are Centrifugal type, designed for operation w/o
FDVLQJZLWKPRWRUIRULQVWDOODWLRQKRUL]RQWDOO\%DFNZDUGFXUYHG
impellers are mounted directly on the motor rotor, statically and
G\QDPLFDOO\EDODQFHGLQDFFRUGDQFHZLWK',1,62)DQ
PRWRUVDUH,3SURWHFWHGDQGFODVV)LQVXODWHG
• A suitable speed variation system shall be required for the
RSWLPXPDGMXVWPHQWRIWKHGHVLUHGRSHUDWLQJSRLQW 1RW 
LQFOXGHGLQ6.0VWDQGDUGVXSSO\ ,QRUGHUWROLPLWWUDQVPLVVLRQ
of noise and vibration, complete fan-motor assembly is mounted
RQÀRDWLQJVXEEDVHZLWKDQWLYLEUDWLRQPRXQWV
•,QHMAH-1 series, units are supplied with either belt driven
centrifugal fans or direct driven centrifugal fans depending on Fig 4: Coils are installed on rails and are
IUHHWREHUHPRYHGIURP$+8IRUFOHDQLQJ
the requirement.

Options
• Units can be provided with standby fans on request.
•7KHIDQVVKDOOEHHTXLSSHGZLWKDÀRZPHDVXULQJGHYLFH
DVRSWLRQ:LWKWKHÀRZPHDVXULQJGHYLFHLWLVSRVVLEOHWR
PHDVXUHPRQLWRUWKHÀRZHDVLO\DIWHUWKHIDQLVLQVWDOOHG

S.K.M Air Conditioning LLC


7
Modular Air Handling Unit HMAH Series

Fig 5: Eliminators
installed on rails are
UHPRYDEOHIRUFOHDQLQJ

Fig 9: Fine Filter Section Fig 10: Pre Filter Section

Fig 6: Stainless
6WHHO 'RXEOH 6NLQ Electric Heater Section
&RQGHQVDWH'UDLQ3DQ
(OHFWULF KHDWHU EDWWHULHV DUH DYDLODEOH LQ D ZLGH UDQJH RI
capacity (kW) and steps as an integral part of HMAH units.
,W FRQVLVWV RI ¿QQHGW\SH KHDWLQJ HOHPHQWV FRQVWUXFWHG IURP
80/20 nickel chrome resistance wire, which is connected
to terminal pins and centered in stainless steel grade 304L
VKHDWK PHWDO WXEHV E\ FRPSUHVVHG PDJQHVLXP R[LGH 7KH
Filter Section ¿QVDUHKHOLFDOPLOGVWHHOJDOYDQL]HGDQGWLJKWO\ZRXQGDURXQG
$ZLGHYDULHW\RI¿OWUDWLRQV\VWHPVDUHDYDLODEOHWRPHHWWKH WXEXODUKHDWLQJHOHPHQWV7KHWHUPLQDOSLQVVKDOOEHLQVXODWHG
GLႇHUHQWDSSOLFDWLRQVZKLFKLQFOXGHVÀDW¿OWHUVEDJ IURPPHWDOWXEHE\FHUDPLFEXVKHV(OHFWULFKHDWHUHOHPHQWV
¿OWHUV +(3$ ¿OWHUV DQG RWKHU W\SHV )LOWHUV XVLQJ LQ 6.0 DLU DUH LQ DFFRUGDQFH ZLWK ,(& VWDQGDUGV &RQWUROV DQG VWDUWHU
KDQGOLQJXQLWVDUHLQDFFRUGDQFHZLWK,62DQG(1 FRQWDFWRUVDUH127LQFOXGHGLQWKLVRSWLRQ,IUHTXLUHGKHDWHU
standards. FRQWUROER[FDQEHVXSSOLHGDVRSWLRQ
6WDQGDUGFRPSRQHQWVLQFOXGHGZLWKWKHKHDWHURSWLRQDUH
• Pre Filter
• Finned heating element attached to the heater frame
H30LQDFFRUGDQFHZLWK,62VWDQGDUG
• Primary over temperature protection provided by auto reset
• Fine Filters
high limit safety cut outs
H30LQDFFRUGDQFHZLWK,62VWDQDGUG
• Secondary over temperature protection provided by manual
• +HSD¿OWHU
reset high limit safety cut-out for positive break
8OWUDKLJKDEVROXWH+(3$ +LJK(ႈFLHQF\SDUWLFXODWHDLU )LOWHU
‡-XQFWLRQER[LQFOXGLQJWKHSRZHUDQGFRQWUROWHUPLQDOVIRU
ZLWKHႈFLHQF\LQH[FHVVRIZKHQPHDVXUHGE\XVLQJ'23
heater wiring.
'L2FW\OH3KWKDODWH PHWKRG+(3$¿OWHUVLQ6.0+\JLHQLF$+8
DUHLQDFFRUGDQFHZLWK(1VWDQGDUGV
,I+HDWHU&RQWURO%R[ +&% RSWHGWKHQKHDWHUFRQWUROER[FDQ
•6WDLQOHVVVWHHO¿OWHUUDFN be provided which will include the below.
•,QVSHFWLRQ:LQGRZ • 3-pole magnetic contactor per stage.
•%XONKHDGOLJKWDQG • Control fuse / breaker. Control switch.
•0DQRPHWHUDFURVV¿OWHUVSURYLGHDVVWDQGDUG ‡3RZHUIXVHVFLUFXLWEUHDNHUDVSHU1(&LIWRWDOORDGH[FHHGV
48 Amps.
‡)DFWRU\LQVWDOOHGDLUÀRZVZLWFK1RWHWKDWQHFHVVDU\FRQWUROV
for staging the heater for temperature control to be provided
by others.
Fig 7: Pre Filter
(ePM1 55%) ,IRSWHG7K\ULVWRUFRQWUROOHU>6&5@WKHQLWZLOOLQFOXGHWKHEHORZ
options.
‡7K\ULVWRU V IRUWKHKHDWHU
• Power contactor for thyristor
• Control fuse / breaker. Control switch
‡3RZHUIXVHVFLUFXLWEUHDNHUDVSHU1(&LIWRWDOORDGH[FHHGV
48 Amps
‡)DFWRU\LQVWDOOHGDLUÀRZVZLWFK1RWHWKDWQHFHVVDU\FRQWUROV
for modulating the heater thyristor for temperature control
to be provided by others.

Fig 8: Fine Filter


(ePM1 80%)

8
Electric Heater 6WHDP+XPLGLÀHU
Airflow Option - 1 Option - 2 Option - 3 Option-1 Option-2
Model $LUIORZ
Model HMAH/HMAH-1 CFM Capacity Capacity
No of No of No of NJKU NJKU
HMAH/HMAH-1 CFM kW kW kW
Stages Stages Stages
0202 1000 5 10
0202 1000 3 1 6 1 6 2 0203 1750 5 15
0203 1750 6 1 9 1 9 2 0204 2500 8 15
0204 2500 12 1 15 2 24 2 0303 2917 8 15
0303 2917 12 1 15 2 18 2 0304 4167 10 18
0304 4167 18 2 24 2 36 2 0305 5417 15 25
0305 5417 24 2 30 2 48 2 0306 6667 18 35
0306 6667 30 2 36 2 60 2 0405 7583 18 35
0405 7583 36 2 48 2 72 2 0406 9333 18 35
0406 9333 36 2 48 2 90 2
0407 11083 25 45
0407 11083 48 2 60 2 90 2
0506 12000 25 45
0506 12000 60 2 72 2 108 3
0507 14250 25 45
0507 14250 72 2 90 2 126 3
0508 15938 35 70
0508 15938 72 2 90 2 126 3
0509 18750 90 2 108 3 126 3
0509 18750 35 70
0608 19479 90 2 108 3 162 4 0608 19479 35 70
0609 22917 90 2 126 3 180 4 0609 22917 35 70
0709 27083 126 3 144 4 216 6 0709 27083 35 70
0710 30333 144 4 180 5 270 6 0710 30333 45 90
0711 33583 144 4 180 5 270 6 0711 33583 45 90
0811 38750 144 4 216 6 324 6 0811 38750 45 90
0812 42500 180 5 216 6 324 6 0812 42500 70 90
Table 1 Table 2

Mixing Box Section Plenum (Access) Sections


•0L[LQJER[ZLWKIUHVKDLUDQGUHWXUQDLUGDPSHUVDUHDYDLODEOH
• (PSW\SOHQXPVHFWLRQVFDQEHVXSSOLHGHLWKHUIRUIXWXUHXVH
WRPL[WKHRXWVLGHIUHVKDLUZLWKUHFLUFXODWHGUHWXUQDLU%RWKWKH or for particular applications like access, end vertical assembly,
return and fresh air dampers are sized to handle 0-100% of the end bottom plenum for bottom return air applications and etc.
• Custom sizes to suit a particular requirement can be supplied
total supply air.
as an option.
• Damper blades are available in Aluminium or Stainless
steel with opposed blades. Links are provided for motorized
operation. +\JLHQLF6HDODQWV
• 7KHVHDODQWZKLFKLVXVHGLQVLGHWKH$+8WRVHDOVRPHRI
+XPLGL¿HU6HFWLRQ the components against the air or water leaks is antibacterial,
•7KLVV\VWHPFRQVLVWVRILPPHUVHGHOHFWURGHVWHDPJHQHUDWLQJ QRQWR[LFDQGGRHVQ¶WFRQWDLQDQ\GDQJHURXVRUDOOHUJHQLF
cylinders, steam distribution pipe and necessary controls. components. Sealants used in HMAH & HMAH-1DUHFHUWL¿HG
Steam generating cylinders are mounted on to the AHU within DFFRUGLQJ WR 9',  VWDQGDUG DQG PDWHULDO RI VHDODQW DUH
D VHSDUDWH HQFORVXUH 7KH VWHDP GLVWULEXWRU SDVVHV WKURXJK WHVWHG EDVHG RQ  ,62  VWDQGDUG LQ ORERUDWRLHV  ZKLFK DUH
the unit casing to inject steam in the air stream to reach the DFFUHGLGDWHGDFFRUGLQJWR(1VWDQGDUG
required humidity conditions.
• 21 2)) FRQWURO IRU KXPLGL¿HU LV SURYLGHG DV VWDQGDUG
Stainless Steel condensate drain pan is provided. Access
GRRUYLHZSRUWEXONKHDGOLJKWDQGDLUÀRZVZLWFKDUHSURYLGHG
LQWKHKXPLGL¿HUVHFWLRQ

S.K.M Air Conditioning LLC



Modular Air Handling Unit HMAH Series

Sound Attenuator Section


Sound attenuator can be provided in both supply and return air
VLGH7KHVWDQGDUGGHVLJQLVZLWKVSHFLDOO\GHVLJQHGYHUWLFDO
splitters consisting of sound absorbing material parallel to the air
VWUHDPPDWFKLQJXQLWFURVVVHFWLRQ7ZRGLႇHUHQWPHGLDGHSWKVRI
´ PP >6$7@DQG´ PP >6$7@DUHDYDLODEOHDV
VWDQGDUG2XWHUVNLQRIWKHVSOLWWHUVDUHFRQVWUXFWHGRISHUIRUDWHG
JDOYDQL]HGVWHHO7KHLQVXODWLRQPDWHULDORIVSOLWWHUVDUH¿EHUJODVV
,QVWDOODWLRQUDLOVDUHPDGHRIVWDLQOHVVVWHHO

+HDW5HFRYHU\6HFWLRQ
• +HDW3LSH6\VWHP
,Q RUGHU WR FRQVHUYH WKH HQHUJ\ FRQVXPSWLRQ E\ H[FKDQJLQJ Heat pipe is a simple heat transfer device consisting of two
HQHUJ\EHWZHHQWKHVXSSOLHVDQGH[KDXVWDLUVWUHDPVYDULRXV coils, pre-cooling and re-heating, connected together without
types of heat recovery systems can be provided as an integral any moving part in between them and containing phase
SDUW RI 6.0 DLU KDQGOLQJ XQLWV 7KHVH GHSHQG XSRQ VSHFLDO FKDQJHÀXLG$FFRUGLQJWRWKHDUUDQJHPHQWRIWKHKHDWSLSH
LQVWDOODWLRQDQGRWKHUUHTXLUHPHQWVOLNH coils with respect to other components, it can be used for
HLWKHUGHKXPLGL¿FDWLRQ KRUVHVKRHW\SHDUUDQJHPHQW RUIRU
heat recovery (vertical/horizontal arrangement).
• )L[HG3ODWH+HDW5HFRYHU\6\VWHP
Consists of layers of Aluminum plates, which are separating )RUGHKXPLGL¿FDWLRQIXQFWLRQ KRUVHVKRHW\SHDUUDQJHPHQW 
SUHFRROLQJFRLOLVORFDWHGLQWKHLQFRPLQJDLUÀRZDOORZVWKH
WKHH[KDXVWDQGVXSSO\DLUVWUHDPV7KHH[KDXVWDLUSDVVHV
evaporator cooling coil to work cooler and condense more
WKURXJK WKH H[FKDQJHU IURP HQG WR HQG DQG WKH VXSSO\ DLU
PRLVWXUH5HKHDWFRLOORFDWHGDIWHUWKHHYDSRUDWRUFRLOUHKHDWV
stream individual passages formed by the plates within the the supply air and brings about a more comfortable temperature
H[FKDQJHU DQGUHODWLYHKXPLGLW\7KLVHQWLUHIXQFWLRQRIKXPLGLW\UHGXFWLRQ
  7KH SODWHV VHSDUDWLQJ WKH WZR DLU VWUHDPV DFW DV WKH KHDW is performed while saving energy.
WUDQVIHUPHGLXP7KLVV\VWHPUHFRYHUVVHQVLEOHKHDWRQO\
Plate type heat recovery system is available in both HMAH For heat recovery function (vertical/horizontal arrangement),
& HMAH-1 Series heat pipe coils are installed between the fresh and return
DLU VWUHDPV DQG WZR IDQ VHFWLRQV DUH UHTXLUHG VXSSO\ DQG
H[KDXVWIDQ

• 5RWDU\+HDW5HFRYHU\6\VWHP 7KHUPDO:KHHO
Heat recovery wheels are available to recover either sensible
heat only or both sensible and latent heat to meet the
UHTXLUHPHQWV 7KHUPDO ZKHHOV FRQVWUXFWHG RI $OXPLQXP
coated with heat transfer material (Molecular sieve) which
VKDOOURWDWHE\DQHOHFWULFPRWRUDWFRQVWDQWVSHHG7KHKHDW
wheel rotates between the fresh and return air streams, and
WZRIDQVHFWLRQVDUHUHTXLUHG VXSSO\DQGH[KDXVWIDQ 5RWDU\
+HDW5HFRYHU\V\VWHPLVDYDLODEOHRQO\LQ+0$+VHULHV

10
Dimensional Data BELT DRIVEN FAN PLUG FAN HUMIDIFIER HEATER COIL FILTER MIXING BOX

Section Length mm Section Length mm Section Length mm


Unit Height Section Length mm (For Varies with
Unit Model Airflow (cfm) Unit Width mm Section Length mm Section Length mm Section Length mm Varies with Type
mm HMAH-1 Only) Standard With HCB Option Damper location
and depth of filter

MOTOR LOCATION BACK


and % of F/A
HMAH-0202 1000 900 750 1075 1075 750 375 375 950 750 275
HMAH-0203 1750 900 1075 1075 1075 750 375 375 950 753 400
HMAH-0204 2500 900 1375 1075 1075 750 375 375 950 756 400
HMAH-0303 2917 1225 1075 1175 1175 750 375 375 950 757 400
HMAH-0304 4167 1225 1375 1175 1175 750 375 375 950 760 400
HMAH-0305 5417 1225 1700 1175 1175 750 375 375 950 763 400
HMAH-0306 6667 1225 2000 1175 1175 750 375 575 950 766 400
HMAH-0405 7583 1475 1700 1375 1375 750 495 575 950 767 550
HMAH-0406 9333 1475 2000 1375 1375 750 375 750 950 770 550
HMAH-0407 11083 1475 2325 1375 1375 750 375 750 950 772 725
MOTOR LOCATION SIDE

HMAH-0506 12000 1800 2000 1700 1700 750 375 750 950 773 725
HMAH-0507 14250 1800 2325 1700 1700 750 375 750 950 775 725
HMAH-0508 15938 1800 2575 1700 1700 750 375 750 950 776 725
HMAH-0509 18750 1800 2950 1700 1700 750 375 750 950 778 725
HMAH-0608 19479 2100 2575 2075 2075 750 375 750 950 779 725
HMAH-0609 22917 2100 2950 2075 2075 750 375 950 950 781 725
HMAH-0709 27083 2400 2950 2300 2075 750 575 950 950 783 1025
HMAH-0710 30333 2400 3250 2300 2075 750 575 950 950 785 1025
HMAH-0711 33583 2400 3575 2300 2075 750 575 950 950 787 1025
HMAH-0811 38750 2700 3575 2300 2075 750 575 950 950 789 1150
HMAH-0812 42500 2700 3875 2300 2075 750 575 950 950 791 1150

Table 3

Heat Wheel (For


Unit Height Plate Heat Exchanger Heat Pipe Possible Fan positions:
Unit Model Airflow (cfm) Unit Width mm HMAH-1 Only)
mm
Section Length mm Section Length mm Section Length mm
HMAH-HR-0202 1000 1700 975 1050 950 750
HMAH-HR-0203 1750 1700 1175 1050 950 750
HMAH-HR-0204 2500 1700 1475 1050 950 750
HMAH-HR-0303 2917 2350 1300 1050 950 750
HMAH-HR-0304 4167 2350 1500 1050 950 750
HMAH-HR-0305 5417 2350 1800 1050 950 750
HMAH-HR-0306 6667 2350 2100 1300 950 750 Position 1 Position 2 Position 3
HMAH-HR-0405 7583 2850 1800 1300 950 750 (Bottom Horizontal (Upblast Leaving Air)
HMAH-HR-0406 9333 2850 2100 1350 950 750 (Top Horizontal Discharge) Discharge)
HMAH-HR-0407 11083 2850 2425 1650 950 750
HMAH-HR-0506 12000 3500 2200 1650 950 750
HMAH-HR-0507 14250 3500 2425 1650 950 750
HMAH-HR-0508 15938 3500 2650 1650 950 750
HMAH-HR-0509 18750 3500 3000 1650 950 750
HMAH-HR-0608 19479 4100 2775 1900 950 750
HMAH-HR-0609 22917 4100 3050 1900 950 750
HMAH-HR-0709 27083 4725 3175 - 950 750
HMAH-HR-0710 30333 4725 3375 - 950 750 Position 4 Position 5 Position 6
HMAH-HR-0711 33583 4725 3675 - 950 750 (Upblast Entering Air) (Downblast (Downblast Entering Air)
HMAH-HR-0811 38750 5325 3775 - 950 750 Entering Air)
HMAH-HR-0812 42500 5325 3975 - 950 750

Table 4 Filter Type Filter


Section Length (mm)
Different Filter Arrangements Depth
2" 575
Flat Filter
4" 575
Rigid Filter 12" 950
15" 750
Bag Filter
21" 950
Hepa Filter 12" 950
2" + 15" 750
Flat + Pleated Flat + Bag Filter
Flat Filter Bag Filter Bag + Flat Filter Hepa Filter 2" + 21" 950
Filter
Flat + Rigid Filter 2" + 12" 1075
Flat + Pleated Filter 2" + 4" 575

Plenum Section Hot Water Coil DX Coil UV Lamp- 575 mm Sand Trap Louver Full Face Damper Filter in Neck Sound Attenuator

PEM1 575 mm 375 mm 950 mm SAT1 950 mm


PEM2 750 mm SAT2 1375 mm
PEM3 950 mm

* Heat wheels and belt driven fans are applicable for HMAH-1 series only.

S.K.M Air Conditioning LLC


11
Contact us
P.O Box: 6004, Sharjah, United Arab Emirates
Tel: +971 6 514 3333 | Fax: +971 6 514 3300
Email: [email protected] | [email protected]
Spare Parts Division: [email protected]
^ĞƌǀŝĐĞĞŶƚƌĞ͗ĂŌĞƌƐĂůĞƐΛƐŬŵĂŝƌĐŽŶ͘ĐŽŵ
Toll Free: 800 MYSKM (69756) (UAE only)
UAE

PC: 34326, 2nd Industrial City, Dammam, Saudi Arabia


Dammam: Tell. :+966 3 8123332/4/5 | Fax: +966 3 8123337 / +966 3 8123092
Al-Riyadh: Tel.: +966 11 2914775 | Fax: +966 11 2914771
Jeddah: Tel.: +966 12 6639357 | Fax: +966 12 6639357
Customer Call Center: 920022595 | [email protected]
Service Centre Toll Free: 800 124 0105 (KSA only)
KSA

W͘KŽdž͗ϭϮϭϱ͕ĂƐŵĂŶ͕<ƵǁĂŝƚKĸĐĞ͕DƵƌŐĂď͕<ƵǁĂŝƚ
Tel : +965 22 492 200 | Fax: +965 22 494 400
[email protected]

Kuwait

visit: www.skmaircon.com

097/2023
Supersedes #097 /2022A

You might also like