CONSTRUCTION 30 Questions
CONSTRUCTION 30 Questions
Questions (MODERATE-CHALLENGING)
BUILDING LAWS
(30 Questions, Difficulty Level: MODERATE to CHALLENGING)
by Raison John J. Bassig
Q#6: If you are to design a 380-room hotel located in Makati City, how
many parking slots for cars should you allot to comply with the
provisions of the current National Building Code provisions, rules and
regulations?
a. 76 car parking slots
b. 380 car parking slots
c. 95 car parking slots
d. 127 car parking slots
Q#8: Who has the responsibility to adopt the type and design of
footings and foundations in terms of the appropriate type, adequate
size, and capacity in order to safely sustain the superimposed loads
under seismic or any condition of external forces that may affect the
safety or stability of the structure?
a. Architect
b. Architect and/or Engineer
c. Engineer
d. Structural Engineer
Q#9: As per PD 1096, the portion of the building between floor and
ceiling which is wholly or partly below grade and so located that the
vertical distance from grade to floor below is equal to or greater than
the vertical distance from grade to ceiling.
a. Attic Storey
b. Basement
c. Cellar
d. First Storey
Q#10: During your initial consultation with your client, you have
ascertained that your client's project is a medium-density housing for
your client's own family situated in a 16.4m-wide x 23.35m-deep inside
lot in a newly-developed location. The client then asks you, as the
architect of the project, what would be the largest area for the ground
floor of the house you can build on the lot, considering that the client
wants the house to have abutments on both sides of the lot?
a. Approx. 230sqm
b. Approx. 209sqm
c. Approx. 300sqm
d. Approx. 264sqm
Q#19: As per BP 344 (Accessibility Law), water closet stalls for PWDs
shall permit easy passage of a wheelchair and allow the occupant to
enter a stall, close the door and transfer to the water closet from either
a frontal or a lateral position. For lateral mounting, what is the required
grab bar provisions?
a. A fixed continuous grab bar from one wall to the next.
b. A movable grab bar on one wall and a fixed grab bar at the adjacent
wall.
c. Two fixed grab bars on both sides of the wall.
d. No such requirement as long as the minimum area of the stall is at
1.70m x 1.80m
Q#21: Any building or portion thereof, containing not more than five
guest rooms which are used by not more than five guests where rent is
paid in money, goods, labor or otherwise.
a. Dwelling Unit
b. Aparment House
c. Boarding House
d. Lodging House
Q#22: As per current IRR of PD 1096, the plans and specifications for
indoor and outdoor signages shall be prepared, signed and sealed by
whom?
a. Professional Mechanical Engineer
b. Architect
c. Electronics Engineer
d. Professional Electrical Engineer
Q#25: What is the ratio between the saleable portion and non-saleable
portion of an economic or socialized housing subdivision project?
a. 75% saleable / 25% non-saleable
b. 70% saleable / 30% non-saleable
c. 80% saleable / 20% non-saleable
d. No fixed ratio
Q#26: What is the minimum lot frontage for corner lots in an economic
or socialized housing project?
a. 6.00 meters
b. 8.00 meters
c. 10.00 meters
d. 3.00 meters
Q#27: The aggregate area of all penthouses shall not exceed ____ of
the area of the supporting roof.
a. One-half (1/2)
b. One-third (1/3)
c. One-fourth (1/4)
d. None (No such rule).
Q#28: The vacant space left between the outermost face of the
building / structure and the property lines, e.g., front, rear, right and
left side, according to PD 1096.
a. Easement
b. Setback
c. Yard
d. Court