Manual MA210 Ejes
Manual MA210 Ejes
SL MA-210
User Manual
Revision 1
2010/04 Köcher
1. GENERAL ..............................................................................3
1.1 Function.......................................................................................................... 3
1.2 Features ......................................................................................................... 3
1.3 Dimensions..................................................................................................... 4
2. CONNECTIONS .......................................................................5
2.1 Electrical (8 pin pluggable screw clip)............................................................. 5
2.2 Debug Pins ..................................................................................................... 5
2.3 Stack Connector ............................................................................................. 5
2.4 Optical ............................................................................................................ 5
6. SPECIFICATIONS ..................................................................10
1. General
The SL MA-210 two-channel Optical Transmittance Analyzer (OTA) is an electronic interface that
operates two fiber optic load sensors. The SL MA-210 serves as the interface between the fiber optic
sensor and the processing unit on system level. It should be installed in a weatherproofed road side
cabinet.
1.1 Function:
The interface responds to the optical sensor signal in a dynamic (AC-coupled) manner, i.e. the
electrical signal caused when a load is applied to the sensor decreases to zero as the load remains
applied. At a tunable threshold, a digital trigger signal per channel is generated. This signal is
automatically reset after an adjustable time period. These characteristics allow the SL MA-210
interface to operate without the need for adjustment.
If the interface detects an interruption in the light transmission path of any channels, it flashes a
particular light for each interrupted channel. The output signals (trigger signals) are transmitted via
optocouplers which behave similar to relays, allowing the use of a variety of output circuitry.
1.2 Features:
1.3 Dimensions:
2. Connections
The Board has a GND pin and each channel has four pins for debug proposal. All these outputs are
optionally connected to an analog output header (Ana Con). The four pins are:
Pin Voltage
1 GND
2 GND
3 Vana1 Analog load signal of channel 1
4 Vmon1 Monitor signal of channel 1
5 Vtrg1 Trigger voltage of channel 1
6 Vref1 Reference voltage of channel 1
7 Vana2 Analog load signal of channel 2
8 Vmon2 Monitor signal of channel 2
9 Vtrg2 Trigger voltage of channel 2
10 Vref2 Reference voltage of channel 2
11 – 14 Not Connected
2.4 Optical
SMA-Connectors (SMA series 905) LED Transmitter, Photodetector
Channel 1
Channel 2
Without internal circuit With 1 Jumper E and Pin3 With internal circuit
(remove all jumpers) connected to ground (Close all jumpers)
open collector output
Channel 1 Channel 2
CH 1 CH 2
1) Fit the interface with screws. Take care that road vibrations will not influence the board
and in specific the fiber optic connectors
3) Connect the sensor SMA connectors with transmitters and photodetectors of each
channel. Fasten properly the sensor SMA connectors with transmitters and photo
detectors in order to guarantee smallest attenuation, but do not use any pliers. The
connectors of transmitters and photodetectors are allowed to be interchanged per
channel.
4) Connect the pins 0 (Supply Voltage) and 1 (Ground) to the power supply and the pins 2
and 3 to the output power supply if needed.
7) Test the installation by driving over the embedded sensors and monitor the Trigger signals
(Trigger LEDs) or Vanalog signal (Debug Pin Ax). Test the sensor Error signal (Error LED)
by disconnecting one of the fiber connectors.
6. Specifications
• Do not stare into the LED light beam with unprotected eyes.
• Only turn on power supply after connecting the sensor or with applied safety caps.
• The equipment may only be used for the considered purpose.
• The manual should be stored at hand and be delivered to every user.
• Any changes and the use of spares which are not sold by the manufacturer cause
rejects of warranty.
• Repairs are only allowed to the manufacturer.
Important notice
All the information contained herein is believed to be accurate and reliable. However, SENSOR LINE
assumes no responsibility for its use or for any infringements of patents or other rights of third parties
that may result from its use. No license is granted by implication or otherwise under any patent rights
of SENSOR LINE GmbH.
SENSOR LINE GMBH SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES RELATED TO THE USE OF THIS PRODUCT.
All rights reserved. Reproduction or adaptation of any part of this documentation beyond without
permission of the Copyright owner is unlawful.