Question 1
You are tasked with biologically removing phosphorus in the existing tankage to alleviate the
problems in the tertiary chemical precipitation system. Given the system characteristics, model
and analyze the biological phosphorus removal process in Biowin, considering the following:
Influent System
Parameter Value
Parameter Value
Aerator Volume 4000 m³
Flow rate 35,000 m³/d
Aerator Depth 4.5 m
BOD 127 mg/L
Aerator Width 15 m
Total Kjeldahl Nitrogen 40 mg/L
Clarifier Volume 20,000 m³
Total Phosphorus 6.5 mg/L
Clarifier Depth 4.0 m
TSS 150 mg/L
Clarifier Underflow 15,000 m³/d
VSS 100 mg/L
Splitter flow – waste 500 m³/d
Parameter Value
Parameter Value Aerator Volume 5000 m³
Flow rate 45,000 m³/d Aerator Depth 6m
BOD 150 mg/L Aerator Width 20 m
Total Kjeldahl Nitrogen (TKN) 55 mg/L Clarifier Volume 25,000 m³
Total Phosphorus (P) 8 mg/L Clarifier Depth 5m
TSS 170 mg/L Clarifier Underflow 18,000 m³/d
VSS 120 mg/L Splitter flow – waste 700 m³/d
1. Calculate the effluent concentrations of BOD, TKN, P, TSS, and VSS using Biowin based on
these parameters.
2. Optimize the clarifier underflow and splitter flow – waste such that the effluent Total
Phosphorus (P) is reduced to 4 mg/L. How does this affect the BOD in the effluent?
Question 4
Influent System
Parameter Value
Parameter Value
Flow rate 10,000 m³/d
TF Volume Proposed 900 m³
BOD 127 mg/L
TF Depth 4.5 m
Total Kjeldahl Nitrogen 40 mg/L
Clarifier Volume 20,000 m³
Total Phosphorus 6.5 mg/L
Clarifier Depth 4.0 m
TSS 150 mg/L
Clarifier Underflow 500 m³/d
VSS 100 mg/L
Require 15 mg/L CBOD and 1.0 mg/L DO.