VS-Comm - Card Eng
VS-Comm - Card Eng
64mm
RX TX
extra Communication Expansion (CP) card is available to get more communication ports. In addition, the Status Indicator
expanded communication ports are all multi-functional and able respectively to select and perform an CH2 Communication RX TX
Status Indicator CH2
application from numerous communication modes. Complete
Model Name
VS-D485A-EC
The VS Series PLC Main Unit not only has a built-in CP1 communication port, but also at the EC1 VIGOR LOGO 1306-
Serial Number 0001
Expansion Card Socket is available to install a communication expansion card. Therefore, at the VS1
Manufacturer VIGOR
series, the CP2 is expandable; at the VS2, VSM and VS3 series, the CP2 and CP3 are expandable. DC IN CH2
24V 0V D D TR
Moreover, the VS3 can use the EC3 Expansion Card Socket to expand the CP4 and CP5. Power Input Terminal
CH2 Communication
Connecting Terminal
RS- 232 RS- 485 Distance 50 Meters 50 Meters 1000 Meters 1000 Meters 15 Meters
Comm. Method Half-duplex Half-duplex Half-duplex Half-duplex Half-duplex Half-duplex
VS Computer Link Master (VS Master Station)
When the communication port of VS Series PLC is executing the application type as “VS Computer Link Master”, Baud Rate By the setting of installed project (up to 115,200 bps.)
it works with the LINK instruction and LINK communication table to execute communication procedure. This Connection Method Fixed 5mm Screw-Clamp terminal block
Master Station communicates with VS Slave Station(s) via the “VS Computer Link protocol” (VS protocol).
Power DC24V 25mA
Consumption※ DC5V 50mA DC5V 100mA DC24V 25mA DC24V 50mA DC5V 25mA
DC5V 25mA
VS Series VS Series VS Series VS Series VS Series
PLC PLC PLC PLC PLC Terminal Resistor 120Ω, enabled when two TR terminals are short-connected —
Parameter
By the installed project (via the "COM Port setting" page in the programming software)
VS VS Conguration
Master VS Master VS VS
Slave Station Slave Station Slave Station
Station Station ※ DC 5V from PLC Main Unit; DC 24V from the external DC input terminal
VB VB VB VB VB RX TX RX TX
RX TX RX TX
CH2 CH2
protocol Slave Station protocol Slave Station Slave Station CH2 CH2
CH2 DC IN DC IN CH2
RS- 232 RS- 485 D D SG TR TR 24V 0V 24V 0V D D TR
CH2
RX TX SG
DC IN CH2
24V 0V RX TX SG
MODBUS Slave
When the communication port of VS Series PLC is executing the application type as “MODBUS Slave”, a HMI
or SCADA is able to access data in the VS series PLC(s) via the “MODBUS protocol”.
CPU Link
In order to achieve distributed control, VS Series PLCs use this type of application to have real-time data Connector of Expansion Card
sharing among PLCs. When the connected VS Series PLCs are executing this type of application, one of them
should use the CPUL instruction and CPUL communication table to have real-time data sharing via the
dedicated communication protocol. Slide both the Fix Clips to the right.
D+ D S S X0 X1 X2 X3 X4 X5 X6 X7 D+ D S S X0 X1 X2 X3 X4 X5 X6 X7
485A 485A
CPU LINK CPU LINK CPU LINK CPU LINK CPU LINK X0 1 2 3 4 5 6 7
RX TX
X0 1 2 3 4 5 6 7
RX TX
Station 1 Station 2 Station 1 Station 2 Station n PWR RUN ERR PWR RUN ERR
Y0 1 2 3 4 5 Y0 1 2 3 4 5
DC IN DC IN
RS- 232 RS- 485 EC1
24V 0V 24V 0V
DC24V DC24V
OUTPUT Y INPUT OUTPUT Y
When the communication port of VS Series PLC is executing the application type as “Non Protocol”, non
standardization communication protocol is executed at this port. The customized communication process LOCK OPEN
needs to be completed by PLC's program, through the RS instruction to make receiving and sending
communication operation thus communication task is completed.
This type of application is usually used to link with other peripherals in market, such as temperature controller,
inverter, barcode reader... LOCK OPEN