Ipc 7801
Ipc 7801
Contact:
IPC
3000 Lakeside Drive, Suite 309S
Bannockburn, Illinois
60015-1249
Tel 847 615.7100
Fax 847 615.7105
March 2015 IPC-7801
Table of Contents
1 GENERAL ................................................................. 1 7.5.2 Double-Sided Metal Tape .................................... 9
1.1 Scope .................................................................... 1 7.5.3 High-Temperature Solder .................................... 9
1.2 Purpose ................................................................. 1 7.5.4 Thermally Conductive Adhesive ......................... 9
7.5.5 Attaching Without Damage ................................. 9
2 APPLICABLE DOCUMENTS .................................... 1
7.6 Additional Suggestions ...................................... 10
2.1 Joint Industry Standards ...................................... 1
7.6.1 Long Wires ......................................................... 10
2.2 IPC ....................................................................... 1
7.6.2 Stress Relief ....................................................... 10
2.3 ANSI .................................................................... 1
7.6.3 Adhesive Support ............................................... 10
3 TERMS AND DEFINITIONS ...................................... 2
7.7 Recognizing Potential Issues ............................. 10
4 THERMAL PROFILES – SnPb AND Pb-FREE ....... 3 7.7.1 Variations in Attachments .................................. 10
4.1 Recommended Reflow Profile Specifications ..... 3 7.7.2 Twisted Wires .................................................... 10
4.2 Example of a Typical Tin-Lead Reflow 7.7.3 ‘‘Spikes’’ in Temperature Data .......................... 10
Profile Specifications ........................................... 3 7.7.4 Excessively High or Low Temperature ............. 11
4.3 Example of a Typical Pb-Free (SAC305)
Reflow Profile Specifications .............................. 4 8 VERIFICATION PROFILING FREQUENCY ........... 11
4.4 Pb-Free (SAC305) Reflow Profile 9 REQUIREMENTS FOR OVEN REPEATABILITY
Temperatures ........................................................ 4 CALCULATIONS ..................................................... 11
5 GOLDEN BOARD DESIGN FOR PROCESS 9.1 Cpk – Process Capability Index and Cp –
VERIFICATIONS ....................................................... 4 Capability Performance ..................................... 11
5.1 Optimal Golden Board ........................................ 4 9.2 SMT Oven Stability ........................................... 11
5.2 Other Options for the Golden Board .................. 4 9.3 Process Capability .............................................. 11
5.3 Golden Board Materials ...................................... 5 10 MAINTENANCE AND CALIBRATION
5.3.1 T/C Location ........................................................ 5 GUIDELINES ......................................................... 12
5.3.2 T/C Attachment Methods – Bolt on T/C ............ 5 10.1 Nitrogen Usage .................................................. 12
5.3.3 T/C Attachment Methods – Eyelet T/C .............. 5 10.2 Reflow Oven Operation ..................................... 12
5.3.4 Golden Board T/C Assembly Methods ............... 6 10.2.1 General ............................................................... 12
10.3 General Housekeeping and Daily
6 PROFILING EQUIPMENT REQUIREMENTS ........... 6 Maintenance ....................................................... 12
6.1 Types of Profiling Equipment ............................. 6 10.4 Calibration .......................................................... 12
6.1.1 ‘‘Built-In’’ Profilers .............................................. 6 10.5 Preventive Maintenance ..................................... 12
6.1.2 Remote Profilers .................................................. 7
6.2 Minimum Data Acquisition ................................. 7 Figures
6.3 Data Recording Unit ............................................ 7 Figure 3-1 Identification of Temperature Delta at Peak
6.4 Number of T/Cs ................................................... 7 Reflow Temperature ........................................... 2
6.5 Measurement Accuracy ....................................... 7 Figure 3-2 Example of Reflow Oven Recipe Set Points ..... 2
Figure 3-3 Zones in a Typical Reflow Profile ...................... 2
7 THERMOCOUPLES .................................................. 8
Figure 3-4 Typical Graph Representation of a Thermal
7.1 ‘‘K’’ – Type T/C .................................................. 8 Profile ................................................................. 3
7.2 Wire Length ......................................................... 8 Figure 4-1 Typical SnPb Ramp/Soak/Spike Reflow
7.3 Wire Gage ............................................................ 8 Profile ................................................................. 3
Figure 4-2 Typical Pb-Free Ramp/Spike Reflow Profile ..... 4
7.4 Limit of Error ...................................................... 8
Figure 4-3 Comparision of SnPb vs. Pb-Free Reflow
7.5 T/C Attachment .................................................... 8
Profiles ............................................................... 4
7.5.1 Polyimide Tape .................................................... 8
v
IPC-7801 March 2015
Tables
Table 10-1 Example of Maintenance Schedule
(SAMPLE ONLY) ............................................. 13
vi
March 2015 IPC-7801
1 GENERAL
1.1 Scope This standard provides process control for solder reflow ovens by baseline and periodic verifications of oven
profiles using a standard methodology. Equipment calibration and maintenance guidelines are provided.
This standard is intended to verify the operating parameters of the reflow oven. This standard is not intended for the assem-
bly product profile/recipe. For detailed information on development or verification of a product profile/recipe see IPC-
7530.
This standard does not provide guidance for vapor phase processes.
1.2 Purpose Intended for users of reflow equipment to baseline performance and periodically verify and demonstrate
acceptable oven performance repeatability.
2 APPLICABLE DOCUMENTS
The following documents of the issue in effect on the invitation for bid form a part of this specification to the extent speci-
fied herein.
J-STD-033 Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices
2.2 IPC2
IPC-7351 Generic Requirements for Surface Mount Design and Land Pattern Standard
IPC-7530 Guidelines for Temperature Profiling for Mass Soldering Processes (Reflow & Wave)
IPC-9194 Implementation of Statistical Process Control (SPC) Applied to Printed Board Assembly Manufacture Guideline
IPC-T-50 Terms and Definitions for Interconnecting and Packaging Electronic Circuits
2.3 ANSI3
ASTM/ANSI E230 Standard Specification and Temperature-Electromotive Force (emf) Tables for Standardized Thermo-
couples
1. www.ipc.org
2. www.ipc.org
3. www.ansi.org
1
IPC-7801 March 2015
Liquidus – The temperature at which a solder alloy is com- Figure 3-1 Identification of Temperature Delta at Peak
pletely melted. For more information, see the phase diagram Reflow Temperature
of the solder alloy used. Delta T = Difference between highest measured temperature and
lowest measured temperature.
Peak Temperature – The maximum temperature experienced
at any point on an assembly during reflow soldering. The
highest point on a Reflow Profile.
SP ºC 150 165 195 200 215 350 65
Preheat – A preliminary phase of the soldering process dur- PV ºC 150 165 195 200 215 350 65
conveyor speed and temperatures within each Reflow Zone, Alloy Liquidus Temperature Peak Temperature = Maxumum
TEMPERATURE
Assembly
Temperature
and possibly the flow rates of air or nitrogen. The recipe typi-
cally varies with the thermal mass and other heat transfer Preheat Dwell = Soak Time
Reflow Profile – A graphical representation of temperature for Figure 3-3 Zones in a Typical Reflow Profile
a single or multiple locations on an assembly, plotted against
time, during the reflow process. It may be a recommended
‘‘baseline’’ or Target Profile, or reflect actual measurements.
Also known as ‘‘Oven Profile.’’
Figure 3-3 shows a typical oven profile which is primarily characterized by one temperature-time graph.