Merge
Merge
CE31S3
CULMINATING ACTIVITY
SUBMITTED BY:
2116487
SUBMITTED TO:
Instructor
December 9, 2023
I. Table of Contents
II. Introduction of the Project
a. Project Description
1. Location
2. General Description of the structure
3. Inclusion of the design
b. Code references and Descriptions
c. Other references with description
III. Compilation in Drawing Layout used in Engineering Drawing
a. Drawing
b. Attachment (Assignments)
IV. Profile of Student (Resume Format)
II. Introduction of the Projects
1.) Location
Metrogate Subdivision Trece Martires Cavite
- The National Structural Code of the Philippines (NSCP) is a set of guidelines and
standards for building and other structures in the Philippines. The latest edition is
the 7th edition and it was released in 2015. It provides criteria for ensuring a
building's
stability and safety when subjected to of various loads such as earthquakes, wind,
and gravity. The book covers a wide range of topics, including structural engineering,
building materials, methods, and construction practices.
- According to Article 670, Section 5. Easementof Light and View. The Civil Code of the
Philippines, it states that the live load for the ground floor should be 200 kg per
square meter,while for succeeding floors should have 150 kg per square meter.
- Ceiling height requirements are frequently specified in local building codes, zoning
regulations, or architectural standards rather than structural codes. These requirements
can differ depending on the type of building, its use, and local regulations. The
minimum ceiling height for the ground floor is 2.4 meters, while for succeeding floors
should have at least 2.7 meters.
- The minimum area for the kitchen should beat least 3 square meters and have a
dimension of 1.5 meters. In addition, the toilet should have at least 1.2 square meters
and a dimension of 0.9 meters. Furthermore, rooms for human habitation should
have an area of 6 square meters and have at least 2 square meters in dimension.
- The Revised National Plumbing Code of the Philippines is a document that outlines
the plumbing standards and regulations. It specifies the design, installation, and
maintenance of plumbing systems to ensure safety, efficiency, and hygiene. It helps
in determining the sizes of pipes and vents. Furthermore, it also discusses the
different types of fixtures. It should be noted that the Revised National Plumbing
Code of the
Philippines is a legal document, and compliance with its provisions is frequently a
legal requirement for construction projects.
III. Compilation in Drawing Layout used in Engineering Drawing
D.) Drawings
SITE
N 64 ° 28'
E S 25 ROAD
° 32'
12.00 m
10.00 m E
1
LOT AREA
120 SQ.M.
N425 ° 32'
W m
10.00
S 64 ° 28' VICINITY MAP
ROAD W 2
12.00 m PLATE 1: LOT PLAN
LINE BEARING
3 1-2 S 25 ° 32' E 10.00 m
2-3 S 64 ° 28' W 12.00 m
3-4 N 25 ° 32' W 10.00 m
4-1 N 64 ° 28' E 12.00 m
1 2
1.9502
2.5500
LAUNDRY
1.9498
3
3.4500 T&B
5.1851 sqm
4.7112 3.0138
W
W W
3
D
2
KITCHEN
5.1851 sqm
D
2
DINING ROOM
15.5559 sqm
LIVING ROOM
15.5548 sqm
up to
2nd floor
W D
1
1
1 2
2.4000
3
3.4500
W
4
COMMON
AREA
D
2 MASTE
R
BEDROO
dn to
ground floor
up to
3rd floor
D
BALCONY
1 2
2.4000
3
3.4500
5.1851 sqm
T&B
BEDROOM 2
D
BEDROO
M 1 5.1855 sqm
D
D
2
dn to
second floor HALLW
12.0000
FLOW
FLOW
D ROOF PLAN
A-2 SCALE 1:100
3RD FLOOR
2ND FLOOR
ROOF APEX
0.4500
FIN. FLOOR
FIN. ROAD
E FRONT ELEVATION
A-2 SCALE 1:100
3RD FLOOR
ROOF APEX
2ND FLOOR
0.4500
FIN. FLOOR
FIN. LI
F REAR ELEVATION
A-2 SCALE 1:100
FIREWALL
G RIGHT ELEVATION
A-2 SCALE 1:100
FIREWALL
H LEFT ELEVATION
A-2 SCALE 1:100
DINI
NG
ST
COMMON
AREA MAST
STAIRS
LIVING
AREA
AND
I LONGITUDINAL SECTION
A-2 SCALE 1:100
MASTER' S
BEDROOM CO
KITCHEN
AREA
J CROSS SECTION
A-2 SCALE 1:100
2.5500
1 2
3.1500
FIREWALL
3
1.9498 5.0112 2.9388 FIREWALL
C1 C1
C
1 F1 FTB F2
FTB FTB
100 mm THK CONCRETE
SLAB-ON-FILL (SOF) W/
100mm Ø RSB SP @ 0.40
F FTB F FTB M.O.C., BOTHWAYS
C
1
FTB
C1
C
1
100mm THK GRAVEL BED
C C1
C C F2
1 F FTB 1 F 1 F
K FOUNDATION PLAN
SCALE 1:100
A-2
SCHEDULE OF GIRDER
DIMENSIONS (M) REINFORCEMENT BARS LATERAL TIES
12.00 MARK X Y
6 pcs -16 mm
RB 0.25 0.40 Ø VERTICAL BAR
6 pcs -16 mm Ø
SCHEDULE OF SLAB
C C1 C1 C1 ALONG LONG SPAN
MARK THICKNESS
1 2 3
SUPPORT MIDSPAN
G1 S-2 150
G1 300 150
S-2 S-2
6.0000
C C1 C1
C1
C C C C
G1
G G G
G1 G1 G1
1 2 3
RB RB
6.0000
12.0000
C1
C C C1
RB RB
R R
C1
C C C1
RB
R R R
C1 C1 C1 C1
RB RB RB
1 2 3
C PURLINS @ 300 mm
spacing o.c.
CHECK VALVE
GATE VALVE
1st M WATER METER
Floor
SHO- WATERLINE
WC-3
KS-2
2nd
Floor PIPE RISER 1ӯ PVC
LAV-1 1ӯ PVC CWL
SHO-2
GV 1ӯ PVC CWL
BT-2
GV LAV WC
WC
PROPERTY
LAV LINE
GV
PIPE RISER
SHO KS SHO B
1ӯ PVC
GV
1ӯ PVC CWL
3rd
Floor
LAV-1
SHO-2 2N
D
Ave Water Pressure at water main 345 kPa 1ӯ PVC CW
ASSIGNMENT No. 1
Lot Plan
SUBMITTED BY:
TENIO, MARK REY G. - 2116487
SUBMITTED TO:
ENGR. HEZER A. PEREZ
Instructor
The property is in the Metrogate Subdivision Trece Martires Cavite. The lot plan is
relatively small, measuring approximately 120 square meters. It is perfect for families.
Furthermore, the land is suitable for building a house. Because the lot is 12x10, I just put
a 2 meter
setback in front of it. Furthermore, the sides feature a firewall. There are no other
structures in the immediate vicinity. The only thing in front of you is a road.
SITE
VICINITY MAP
Submitted by: Title: Date:
TENIO, MARK REY G. 9/24/2023
ASSIGNMENT 1: Instructor:
Course/Section:
LOT PLAN
CE 013- CE31S3 ENGR. HEZER PEREZ
TECHNOLOGICAL INSTITUTE OF THE PHILIPPINES - QUEZON CITY
938 Aurora Boulevard, Cubao, Quezon City
ASSIGNMENT No. 2
Architectural Finishes, Furniture, Type of Door, Window to be use
SUBMITTED BY:
TENIO, MARK REY G. - 2116487
SUBMITTED TO:
ENGR. HEZER A. PEREZ
Instructor
October 1, 2023
Couches
. Four Seaters
2.29 m length
0.9 width
Toilet
0.71 m length
0.5 m width
Dining Table
1.22 m length
1.02 m width
Television
1.1 m width
Bathroom Sinks (Width)
0.58 m length
0.61 m width
Bed
. Single
1.83 m long
1.22 m width
. King
1.98 m long
1.8 m width
Stove
0.69 m length
0.76 m width
Bathtub
1.75 m length
0.7 m width
Doors
2.1 m height
0.9 m width
Door 1
2- 0.9 m width
Door 2
0.9 m width
Door 3
Sliding Door
Windows
0.9 m height
1.5240 m height (bathroom)
Cabinets
0.61 m length
1.52 m width
REFERENCES
https://www.wayfair.com/sca/ideas-and-advice/renovation/toilet-dimensions-measurements-to-know-
T68#:~:text=Standard%20toilet%20dimensions%20are%20typically,can%20find%20the%20perfect%20toil
et.
https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&cad=rja&uact=8&ved=2ahUKEwiw9
pSGrNSBAxXoxDgGHbpkBHsQFnoECBIQAw&url=https%3A%2F%2Ffanyv88.com%3A443%2Fhttps%2Fwww.livingcozy.com%2Fblog%2Fdi
ning-room-table-
size%23%3A~%3Atext%3DTo%2520seat%2520up%2520to%2520four%2Cwide%2520and
%252060%252 0inches%2520long.&usg=AOvVaw1udmmqWz8edQDhh1eN1nR9&opi=89978449
https://rapportfurniture.com/blogs/rapport-furniture/sofa-dimensions-guide
https://alliedphs.com/blog/what-are-standard-sizes-for-bathroom-
vanities/#:~:text=Bathroom%20sinks%20come%20in%20standard,to%2023%20inches%20in%20length.
https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&cad=rja&uact=8&ved=2ahUKEwjN4
KP_rNSBAxU5pVYBHelrDlYQFnoECAgQAw&url=https%3A%2F%2Ffanyv88.com%3A443%2Fhttps%2Fwww.wakefit.co%2Fselect-bed-
size&usg=AOvVaw0fPaFxwE1GGV7DyA698p08&opi=89978449
https://www.google.com/url?
sa=t&rct=j&q=&esrc=s&source=web&cd=&cad=rja&uact=8&ved=2ahUKEwjqy oeVrdSBAxVH-
WEKHa8TBhUQFnoECAoQAw&url=https%3A%2F%2Ffanyv88.com%3A443%2Fhttps%2Fwww.wakefit.co%2Fselect-bed-
size%23%3A~%3Atext%3DA%2520king%252Dsize%2520bed%2520furniture%2Chave%2520plenty
%252 0of%2520personal%2520space.&usg=AOvVaw0fPaFxwE1GGV7DyA698p08&opi=89978449
https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&cad=rja&uact=8&ved=2ahUKEwiuz
MjlrdSBAxUef_UHHQ3MC9cQFnoECAoQAw&url=https%3A%2F%2Ffanyv88.com%3A443%2Fhttps%2Fwww.linkedin.com%2Fpulse%2Fwhat
-sizes-household-bathtubs-circular-bathtub-size-common-suki-
tang%23%3A~%3Atext%3DHowever%252C%2520most%2520bathtubs%2520use%2520a%2Cused%252
0bathtub%2520is%25200.8%2520meters.&usg=AOvVaw3RSshJ1rbnJXulH-L1-wYt&opi=89978449
TECHNOLOGICAL INSTITUTE OF THE PHILIPPINES - QUEZON CITY
938 Aurora Boulevard, Cubao, Quezon City
ASSIGNMENT No. 3
Computation of Air Space, Natural Lighting and Ventilation, Space Planning
SUBMITTED BY:
TENIO, MARK REY G. - 2116487
SUBMITTED TO:
ENGR. HEZER A. PEREZ
Instructor
October 1, 2023
COMPUTATIONS
Living Room Computation:
Airspace: 14m3
Ceiling Height: 2.7 m
Occupants: 3
Ratio: 4:2
14m3 x3 = 42 m3
42 m3 / 2.7 m =15.5556 m2
15.5556 m2= 4x(2x)
x = 1.3944
Minimum Dimensions:
4 (1.3944) = 5.5776 m
2 (1.3944) = 2.7888 m
Minimum Area:
5.5776 m x 2.7888 m = 15.5548 m2
For Window:
1.5555 m2
15.5556 m2 = 1.6x(2.3x)
x = 2.0560
Minimum Dimensions:
1.6 (2.0560) = 3.2896 m
2.3 (2.0560) = 4.7288 m
Minimum Area:
3.2896m x 4.7288 m = 15.5559 m2
For Window:
1.5556 m2
Kitchen Computation:
Airspace: 14m3
Ceiling Height: 2.7 m
Occupants: 1
Ratio: 2.7:4
14m3x 1 = 14 m3
14 m3 / 2.7 m = 5.1852 m2
5.8152 m2 = 2.7x(4x)
x = 0.6929
Minimum Dimensions:
2.7(0.6929) = 1.8708 m
4(0.6929) = 2.7716 m
Minimum Area:
1.8708 m x 2.7716 m = 5.1851 m2
For Window:
0.5185 m2
5.1852 m2 = 2x(3.2x)
x = 0.9001
Minimum Dimensions:
2 (0.9001) = 1.8002 m
3.2 (0.9001) = 2.8803 m
Minimum Area:
1.8002 m x 2.8803 m = 5.1851 m2
For Window:
0.5185 m2
Bedroom Computation:
Airspace: 14m3
Ceiling Height: 2.7 m
Occupants: 1
Ratio: 2:4
14m3 x 2 = 14 m3
14 m3 / 2.7 m = 5.1852 m2
5.1852 m2 = 3x(4x)
x = 0.6573 m
Minimum Dimensions:
3(0.6573) = 1.9719 m
4(0.6573) = 2.6292 m
Minimum Area:
1.6102 m x 3.2204 m = 5.1855 m2
For Window:
0.5186 m2
10.3703 m2 = 3.4x(4x)
x = 0.8732
Minimum Dimensions:
3.4(0.8732) = 2.969 m
4(0.8732) = 3.4928 m
Minimum Area:
2.969 m x 3.4928 m = 10.3701 m2
For Window:
1.0370 m2
Toilet and Bathroom Computation(Master Bedroom):
Airspace: 14m3
Ceiling Height: 2.7 m
Occupants: 1
Ratio: 1.7:2.1
14m3x2 = 14 m3
14 m3/ / 2.7 m = 5.1852 m2
5.1852 m2 = 1.7x(2.1x)
x = 1.2052 m
Minimum Dimensions:
1.7 (1.2052) = 2.0488 m
2.1 (1.2052) = 2.5309 m
Minimum Area:
2.0488 m x 2.5309 m = 5.1853 m2
For Window:
0.5185 m2
10 mm Ø TIES 10 mm Ø TIES 10 mm Ø TIES
@ 150 mm o.c. @ 150 mm o.c. @ 150 mm o.c.
6-16 mm Ø
Vertical 6-16 mm Ø 6-16 mm Ø
Bars
Vertical Vertical Bars
Bars
THIRD FLOOR
SECOND TO
SIZE 300 mm x 300 mm SIZE 250 mm x 400 mm
MAIN BARS 6 BARS 16 Ø MAIN BARS 6 BARS 16 Ø
STIRRUPS 10 mm Ø 6" spacing STIRRUPS 5-10 mm Ø @ 150 mm spacing both
ends Rest 10 mm Ø @300 mm spacing
ASSIGNMENT No. 6
Plumbing Fixtures and Accessories
SUBMITTED BY:
TENIO, MARK REY G. - 2116487
SUBMITTED TO:
ENGR. HEZERA. PEREZ
Instructor
December 9, 2023
FURNITURE LOCATION NUMBER OF SETS
Shower 3 sets
Ground Floor to
Third Floor
EDUCATIONAL ATTAINMENT
• Technological Institute of the Philippines (Senior High School)– Quezon City
• Sto. Nino Parochial School - Quezon City
• Sto. Nino Parochial School - Quezon City
ACHIEVEMENTS/HONORS
Academic Awards Achieved
• Recipient, With Honors
Grade 10 Academic Excellence Award
Sto. Nino Parochial School - Quezon City
PERSONAL QUALITIES
• Friendly
• Responsible
• Communication skills
• Open-mindedness
• Empathy
• Respectful
• Good Listener
• Appreciative