0% found this document useful (0 votes)
20 views1 page

CLASSES-Foundation Details

The document contains detailed structural foundation layout plans and specifications, including dimensions and materials used for various components. It outlines the design of concrete slabs, plinth beams, and reinforcement details, with specific references to scales and construction standards. Additionally, it includes section views and notes on the construction process, emphasizing the importance of proper material specifications.

Uploaded by

Boniface Marwa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views1 page

CLASSES-Foundation Details

The document contains detailed structural foundation layout plans and specifications, including dimensions and materials used for various components. It outlines the design of concrete slabs, plinth beams, and reinforcement details, with specific references to scales and construction standards. Additionally, it includes section views and notes on the construction process, emphasizing the importance of proper material specifications.

Uploaded by

Boniface Marwa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

2e 2e

2e 2e

TERRACE FF 2e 2i
2e

2e 2e
2e 2e

SECTION B11-B11
(Scale 1:15)

A B C D E F G H J K L M
41670
B11 B11 75mm kicker
25T8-2f-100c/c 2e 2e
GF 2e
3615 3955 3785 3885 3685 3785 3785 3785 3785 3980 3625 2e

6T16-2j
2e 2e
2i

2e 2e

CB2/C2 CB2/C2 2e 2e
CB2/C2 CB2/C2 CB2/C2 CB2/C2
B11 B11 SECTION B11-B11
4 4 (Scale 1:15)

11

11
13

12

13

12
2e 2e 6T16-2e
10 10 2e 2e

150 THICK 150 THICK BR TF T8-2f-100c/c


150 THICK BRC A142 - SLAB SLAB (S8
9 9
C 2i
BRC A142 - SLAB SLAB (S8
2e 2e

BRC A142 - SLAB SLAB (S8 A1


14 14
4085

4085
4215
8 8

0 2e
15 15 2e
7 7
- T 2e 2e

SLHI
16 16
6 6
BR ABCK

20R x 0.150

20R x 0.150
19G x 0.350

19G x 0.350
SECTION B11-B11 75mm kicker
C
17 17
5 5 (Scale 1:15)
A1 SL
4215
18 18
4 4 AB
0 19
CB2/C2
19
- T 3 CB2/C2 CB2/C2
3 (S
SLHI 20 20 8 8T16-2f-125B2
3 ABCK DOWN
2
DOWN
2
3 B11 B11

450
SL 1
CB2/C2
1
9T16-2f-125B1
A B
UP CB2/C2 CB2/C2 CB2/C2 CB2/C2 UP
CB2/C2
25T8-2f-100c/c
(S
8
2540

2540
BR CB2/C2 6T16-2j
C BR
A1 C
4215
12490

12490
0 A1

50
4215
CB2/C2
- T
2 SLHI 0
- T 2 600 400 600
ABCK SLHI
CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2 SL CB2/C2 CB2/C2 ABCK CB2/C2 CB2/C2 CB2/C2 CB2/C2
AB SL
(S
8
AB 1600
(S
8
BR 2e 2e

BR C BR BR BR SF 2e 2e

C
A1 1
A1 1
42 50 C
A1 1
C
A1 1 C
A1 1 2e 2e
2i CB2:1600X1400X450MM
42 50 - TH 42 50 42 50 42 50
5865

5865
- TH SL IC - TH - TH - TH 2e 2e

SL IC AB K SL IC SL IC SL IC
2e 2e

AB K SL AB K AB K AB K SECTION B11-B11
SL AB SL SL SL (Scale 1:15)
AB (S AB AB AB
(S 8 (S (S (S
8 8 8 8
B11 B11
25T8-2f-100c/c 8T16-2f-200B2
6T16-2j
1 1
CB2/C2
CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2

600
3615 3955 3785 3885 3685 3785 3785 3785 3785 3980 3625

41670
FF 2e

2e
2e 2e

2e

2e
2i
C2

1400

200
A B C D E F G H J K L M
2e

2e 2e
2e
B1

2500
SECTION B11-B11 B1
(Scale 1:15)

STRUCTURAL FOUNDATION LAYOUT (Scale 1:100) 9T16-2f-200B1

B11 B11

600
25T8-2f-100c/c

6T16-2j

A B C D E F 41670
G H J K L M

3615 3955 3785 3885 3685 3785 3785 3785 3785 3980 3625
CB2:1600X1400X450MM
6T16-2e

GF
CB2/C2
CB2/C2 CB2/C2

4 4
11

11
13

12

13

12
CB2/C2 CB2/C2 CB2/C2
BR BR COLUMNS (C2) DETAILS
10
C C 10
BR (Scale 1:35)
9 A1 1 A1 1 9 C
14 42 5 42 50 14 A1 1
8 0 8 42 50
- T - TH
4085

4085
SLHI - TH
15 15
7 SL IC 7

BR
16
ABCK AB K 16 SL IC
6 6 AB K
20R x 0.150

20R x 0.150
19G x 0.350

19G x 0.350
C 17 SL SL 17

A1 1 5
AB AB 5 SL
42 5
18 18
AB
0 4 (S (S 4

- T 19
8 8 19 (S
SLHI
3 3 8
ABCK
20 20
2 2 250
3 SL 3
DOWN DOWN
1 1
AB UP UP 3T16-1c
(S CB2/C2 CB2/C2 CB2/C2
8 CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2
200

450
2540

2540
T8-1f-@150c/c 3T16-1c
CB2/C2

450
12490

12490
T8-1g-@100c/c
3T20-1d
SECTION A2-A2
2 2 PLINTH BEAM DETAILS
3T20-1d
CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2 (Scale 1:15) SECTION A4-A4
CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2
PLINTH BEAM DETAILS
150mm thick concrete slab (Scale 1:15)

reinforced with BRC A142 150mm thick concrete slab


450x200 Plinth beam reinforced with BRC A142
BR
BR
C
on 1000g polythene sheet on 1000g polythene sheet
BR BR C
to details
C C A1 1
A1 1
42 50
50mm murram blinding 50mm murram blinding
A1 1 A1 1 42 5
42 50 42 50 0 - TH
5865

5865
- TH - TH - T SL IC
SL IC SL IC SLHI AB K
AB K AB K ABCK
SL
SL
AB
450x300 Plinth beam
SL SL AB
AB AB
(S
(S to details
(S (S 8
8
8 8 250mm foundation wall 300mm hardcore laid in layers
300mm hardcore laid in layers not exceeding 150mm compacted
250mm foundation wall to engineers approval
not exceeding 150mm compacted
1 1 T10-1b-@100c/c
to engineers approval 3T10-1a
CB2/C2 CB2/C2 CB2/C2
CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2 CB2/C2
T10@100c/c
3T10-1a

3615 3955 3785 3885 3685 3785 3785 3785 3785 3980 3625
SECTION S-001
STRIP FOUNDATION DETAILS
(Scale 1:30)
SECTION S-002
41670
STRIP FOUNDATION DETAILS
A B C D E F G H J K L M (Scale 1:30)

BEAM-COLUMNS LAYOUT (Scale 1:100)

NOTES. Project Title. Designed by Drawing Title Scale


GENERAL. STRUCTURAL. CONSTRUCTION. PLUMBING. ALL INSPECTION CHAMBERS COVERS AND
DO NOT SCALE OF THESE DRAWINGS. PROPOSED EDUCATION
FOR ALL R.C WORK REFER TO S.E'S EXCAVATIONS,FILLING AND COMPACTION TO BE ALL PLU MBING AND DRAINAGE TO COMPLY WITH FRAMING SHALL BE CAST IRON TO COMPLY
ALL DIMENSIONS IN MM UNLESS OTHERWISE IN ACCORDANCE WITH ENGINEER'S INSTRUCTIONS FACILITY .
DETAILS . . CITY COUNCIL'S SPECIFICATIONS . WITH BS497. 1:100
SPECIFIED. Layout ID
FOUNDATION DEPTH TO BE DETERMINED ON SITE . DRAINS PASSING BENEATH BUILDINGS AND
ALL LEVELS AND DIMENSIONS SHOULD BE ALL UNDERGROUND FOUL AND DRAIN PIPES
ALL SOIL UNDER THE SLAB AND AROUND THE DRIVEWAYS TO BE ENCASED IN 150MM THICK
CHECKED BEFORE COMMENCEMENT OF ANY WORK. SHALL BE UPVC TO COMPLY WITH BS5255 FOUNDATION FLOOR LAYOUT .
ALL WALLS LESS THAN 200MM TO BE REINFORCED EXTERNAL FOUNDATION TO BE TREATED WITH CONCRETE SURROUND. Client. Date
ANY DISCREPANCIES TO BE REPORTED TO THE &DETAILS
WITH HOOP IRON AT ALTERNATE COURSES . ANTI-TERMITE CONTROL . ALL MECHANICAL WORK MUST BE COORDINATED
OFFICE OF THE CONSULTANT. STORM WATER DRAIN TO COMPLY WITH BS556. Revisions
WITH THE MECHANICAL AND ELECTRICAL
THIS DRAWING IS TO BE READ IN CONJUCTION WITH
ENGINEER'S AND CLARIFICATIONS MADE BEFORE
SPECIFICATIONS AND ALL OTHER RELEVANT
THE WORKS BEGIN.
DRAWINGS. +254 700 929 007.