Arduino-Basic-Sensors-and-Calibration-Lesson-2
Arduino-Basic-Sensors-and-Calibration-Lesson-2
Temperature Sensors
Sensor Range Functionality Uses Calibration
Process
LM35 -55°C to 150°C Analog output Thermometers, Compare
proportional to weather readings with a
temperature monitoring standard
thermometer;
adjust for offset
in the code
DS18B20 -55°C to 125°C Digital Industrial Use a standard
temperature temperature thermometer
readings with monitoring for validation;
high precision no physical
calibration
needed
DHT11/DHT22 0°C to 50°C Measures HVAC, Cross-check
(DHT11), -40°C temperature agriculture with reference
to 80°C and humidity sensors; adjust
(DHT22) software if
necessary
Humidity Sensors
Sensor Range Functionality Uses Calibration
Process
DHT11/DHT22 20%-90% RH Measures Weather Expose to
(DHT11), 0%- relative stations, known
100% RH humidity greenhouses humidity
(DHT22) environments
using salt
solutions
Light Sensors
Sensor Range Functionality Uses Calibration
Process
LDR (Light 1 lux to 10,000 Measures Smart lighting, Measure light
Dependent lux ambient light photography levels under
Resistor) intensity known
conditions; map
values in code
TSL2561 0.1 lux to Digital light Brightness Validate against
40,000 lux intensity adjustment a lux meter
measurements systems
Gas Sensors
Sensor Range Functionality Uses Calibration
Process
MQ Series (e.g., 100 ppm to Detects gases Safety systems, Expose to
MQ-2, MQ-7) 10,000 ppm like CO, CH4, air quality known gas
and LPG monitoring concentrations;
adjust
sensitivity
potentiometer
CO2 Sensors 0-5000 ppm Measures CO2 Indoor air Use calibration
(e.g., MH-Z19) levels quality, protocol in the
greenhouses datasheet; zero
using clean air
Sound Sensors
Sensor Range Functionality Uses Calibration
Process
KY-038 52 dB to 100 dB Detects sound Alarms, voice Use a sound
Microphone levels control meter for
reference
levels; adjust
onboard
potentiometer
Pressure Sensors
Sensor Range Functionality Uses Calibration
Process
BMP180/BMP280 300 hPa to Measures Weather Cross-check
1100 hPa atmospheric stations, with a
pressure and altimeters barometer;
temperature apply
corrections in
code
Touch Sensors
Sensor Range Functionality Uses Calibration
Process
TTP223 Capacitive Detects touch Touch buttons, Adjust
sensing events panels sensitivity via
code
Environmental Sensors
Sensor Range Functionality Uses Calibration
Process
Soil Moisture 0-100% Measures soil Agriculture, Test in different
Sensor moisture levels gardening soil conditions;
adjust
threshold
values in code
BH1750 1-65,535 lux Measures light Solar systems, Validate against
intensity photography a professional
digitally lux meter
Flame Sensors
Sensor Range Functionality Uses Calibration
Process
KY-026 Flame Up to 100 cm Detects Fire detection, Use a lighter at
Sensor (depends on infrared light safety systems different
flame size) emitted by distances;
flames adjust
sensitivity via
potentiometer
Vibration Sensors
Sensor Range Functionality Uses Calibration
Process
SW-420 N/A (on/off Detects Alarms, Test in various
output) vibrations or structural vibration
shocks health scenarios;
monitoring adjust
sensitivity with
onboard
potentiometer
Rain Sensors
Sensor Range Functionality Uses Calibration
Process
YL-83 Rain Analog Detects rain or Weather Test with
Sensor (wetness moisture stations, smart varying
intensity) and irrigation amounts of
Digital (on/off) water; adjust
thresholds in
code
Gesture Sensors
Sensor Range Functionality Uses Calibration
Process
APDS-9960 10-20 cm Detects Gesture control, Test with hand
gestures smart devices gestures; adjust
(swipe, sensitivity in
proximity) and code
RGB light
GPS Sensors
Sensor Range Functionality Uses Calibration
Process
NEO-6M GPS Global coverage Provides Navigation, Verify with
Module location tracking known
(latitude, systems coordinates and
longitude) and adjust data
time data parsing settings
Camera Modules
Sensor Range Functionality Uses Calibration
Process
OV7670 VGA resolution Captures still Surveillance, Adjust focus
(640x480) images or video image manually;
processing ensure proper
lighting for
testing
Infrared Sensors
Sensor Range Functionality Uses Calibration
Process
IR Receiver 5-10 meters Receives IR TVs, home Test with an IR
Module (e.g., signals for automation remote; verify
TSOP1838) remote controls frequency
compatibility
pH and EC Sensors
Sensor Range Functionality Uses Calibration
Process
EC Sensor (e.g., 0-10 mS/cm Measures Hydroponics, Calibrate with
Gravity EC) electrical soil analysis standard EC
conductivity solutions
(salinity)
Biometric Sensors
Sensor Range Functionality Uses Calibration
Process
Fingerprint N/A Captures and Security Test with
Sensor (e.g., verifies systems, multiple
R307) fingerprints biometric fingerprints;
attendance register
templates
accurately
Wind Sensors
Sensor Range Functionality Uses Calibration
Process
Anemometer 0-30 m/s Measures wind Weather Validate with a
speed stations, wind commercial
turbines anemometer