0% found this document useful (0 votes)
13 views6 pages

Alternadores

The document provides detailed specifications for a three-phase synchronous generator winding QY311, designed for 4 poles at 50Hz and 60Hz operation. Key features include a maximum over-speed of 2250r/min, a power factor of 0.8, and various voltage ratings depending on the configuration. It also includes efficiency curves, short circuit characteristics, and mechanical specifications for the generator's construction.

Uploaded by

Javier Orellana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views6 pages

Alternadores

The document provides detailed specifications for a three-phase synchronous generator winding QY311, designed for 4 poles at 50Hz and 60Hz operation. Key features include a maximum over-speed of 2250r/min, a power factor of 0.8, and various voltage ratings depending on the configuration. It also includes efficiency curves, short circuit characteristics, and mechanical specifications for the generator's construction.

Uploaded by

Javier Orellana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

QYI224G

THREE-PHASE SYNCHRONOUS GENERATOR


WINDING QY311 Datasheet for 4 poles -50Hz @ 1500rpm/ 60Hz @ 1800rpm
Ambient Temperature 40°C Method of Cooling Air cooling
Temperature Rise 125°C Direction of Rotation Clockwise
Insulation Class H Maximum Over-speed 2250r/min
Power Factor 0.8 Degree of Protection / Enclosure IP23
Excitation Brushless Altitude 1000m
Winding Pitch 2/3 Stator winding DLL
Pole 4 Number of Terminal 12
Duty S1- Continuous Rotor With damping cage
Waveform TIF<50 THF<2%
Waveform distortion BS EN 61000-6-2&BS EN 61000-6-4,VDE 0875G,VDE0874N
Radio interference Noload<1.5%,Non-distorting balanced linear load<5%
Standard Selection PMG
AVR MODEL AVR
SX460 AS440 KRS440 MX341B MX321
Voltage Regulation - in steady state condition ±1.0 ±1.0 ±1.0 ±0.5 ±0.5
Short Circuit Current Capacity Control does not sustain a short circuit current 390A
Electrical Characteristic
Frequency Hz 50 60
Voltage ( series star ) Y V 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277
Voltage ( parallel star ) YY V 190/110 200/115 208/120 220/127 208/120 220/127 230/133 240/138
Voltage ( series delta ) Δ V 220 230 240 254 240 254 266 277
kVA 85 85 85 75 93.8 97.5 100 103.8
Rated power at Class H (125ºC) temperature rise
kW 68.0 68.0 68.0 60.0 75.0 78.0 80.0 83.0
4/4% 89.9 90.1 90.2 90.9 90.5 90.8 90.9 91
Efficiency at Class H (P.F.=0.8) 3/4% 90.8 91 91 91.1 91.3 91.5 91.6 91.7
2/4% 91.2 91.1 91.1 90.9 91.8 91.8 91.8 91.8
4/4% 92.1 92.4 92.7 93.1 92.6 92.8 93 93.1
Efficiency at Class H (P.F.=1.0) 3/4% 92.9 93 93.1 93.2 93.3 93.4 93.6 93.7
2/4% 93.3 93.3 93.2 93 93.7 93.8 93.8 93.7
Reactances (%) at Class H
Direct axis synchronous reactance unsaturated Xd 2.43 2.2 2.04 1.6 2.66 2.47 2.32 2.21
Direct axis transient reactance saturated X'd 0.19 0.17 0.16 0.13 0.2 0.19 0.17 0.17
Direct axis subtransient reactance saturated X"d 0.13 0.12 0.11 0.09 0.14 0.13 0.12 0.12
Quadrature axis synchronous reactance unsaturated Xq 1.12 1.01 0.94 0.74 1.22 1.13 1.06 1.01
Quadrature axis subtransient reactance saturated X"q 0.17 0.15 0.14 0.11 0.15 0.14 0.13 0.12
Leakage reactance X1 0.07 0.06 0.06 0.05 0.08 0.07 0.07 0.07
Negative sequence reactance saturated X2 0.16 0.14 0.13 0.1 0.15 0.14 0.13 0.12
Zero sequence reactance unsaturated X0 0.11 0.1 0.09 0.07 0.11 0.1 0.1 0.09
Short-circuit ratio Kcc 0.4115 0.4545 0.4902 0.6250 0.3759 0.4049 0.4310 0.4525

Short-circuit transient time constant (sec.) T'd 0.03


Subtransient time constant (sec.) T"d 0.008
Open circuit time constant (sec.) T'do 0.75
Armature time constant (sec.) Tα 0.007
Stator Winding Resistance (20℃) ohm 0.055
Rotor Winding Resistance (20℃) ohm 0.94
Exciter Stator Resistance (20℃) ohm 20
Exciter Rotor Phase resistance ohm 0.08
No load excitation current io (A) 0.5 0.52 0.6 0.5 0.5 0.51 0.52 0.53
Full load excitation current ic(A) 1.8 1.8 1.9 1.8 1.8 1.8 1.9 1.9
Cooling air requirement m3/sec 0.216m3/s 458cfm 0.281m3/s 595cfm
Mechanical Characteristic
Configuration Single Bearing Double Bearing
Type of Construction B2-SAE IM B34
Total Weight - kgs 355 342
Weight wound stator - kgs 128 128
Weight wound rotor - kgs 126.75 118.38
Inertia (J) [kgm2] 0.7136kgm2 0.6818kgm2
Drive end bearing / Lubrication BALL.6312-2RS(ISO)
Non-drive end bearing / Lubrication BALL.6309-2RS(ISO) BALL.6309-2RS(ISO)
Packing crate size(cm) 90X55X84 90X49X84
QYI224G
50 Winding 311
Hz THREE PHASE EFFICIENCY CURVES
QYI224G
60 Winding 311
Hz THREE PHASE EFFICIENCY CURVES
QYI224G

Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated Speed


Based on star (wye) connection.
50 10000

Hz
SYMMETRICAL

ASYMMETRICAL
1000
CURRENT (Amps)

100

10
0.001 0.01 0.1 1 10
TIME (secs)

Sustained Short Circuit = 390 Amps

60 10000
Hz

SYMMETRICAL

ASYMMETRICAL
CURRENT (Amps)

1000

100
0.001 0.01 0.1 1 10
TIME (secs)

Sustained Short Circuit = 460 Amps


Note 1 Note 2
The following multiplication factors should be The following multiplication factor should be used to convert the
used to adjust the values from curve between values calculated in accordance with NOTE 1 to those applicable
time 0.001 seconds and the minimum current to the various types of short circuit :
point in respect of nominal operating voltage :
50Hz 60Hz 3-phase 2-phase L-L 1-phase L-N
Voltage Factor Voltage Factor Instantaneous x 1.00 x 0.87 x 1.30
380v X 1.00 416v X 1.00 Minimum x 1.00 x 1.80 x 3.20
400v X 1.07 440v X 1.06 Sustained x 1.00 x 1.50 x 2.50
415v X 1.12 460v X 1.12 Max. sustained duration 10 sec. 5 sec. 2 sec.
440v X 1.18 480v X 1.17 All other times are unchanged
The sustained current value is constant irrespective
of voltage level
Note 3
Curves are drawn for Star (Wye) connected machines. For other
connection the following multipliers should be applied to current
values as shown :
Parallel Star = Curve current value X 2
Series Delta = Curve current value X 1.732

You might also like