IAM Report
IAM Report
locations:
Test Report
☐LOCATION 1:
UL India Private Limited,
Laboratory building, Kalyani Platina
Campus, Sy.no.129/4, EPIP Zone,
Phase II, Whitefield,
Bangalore – 560 066
RAYZON SOLAR
P:91-80-41384400
☐LOCATION 2:
☐LOCATION 3:
UL India Private Limited, 30/A, I
Stage, Vishveshwarya Industrial
Estate, Doddanekkundi Industrial
Area, Bangalore - 560048
☒Other:
(#Refer Page no. 4 for Test
lab location)
General details
RAYZON SOLAR PRIVATE LIMITED
Block no 94/1/1F,94/1/3,102/1,103,104,
Customer / Applicant
105,109,110,118,119,120
Surat, Gujarat, 394110, INDIA
RAYZON SOLAR PRIVATE LIMITED
Block no 94/1/1F,94/1/3,102/1,103,104,
Manufacturer
105,109,110,118,119,120
Surat, Gujarat, 394110, INDIA
Program OTHER
Number of Samples 01
Refer Summary of Test results for multiple
UL. Sample Identification 6934287
samples
Manufacturer Serial Number
RSAATG2080224000010
(if any)
Condition of IUT on receipt Good
Page 2 of 11
This document is digitally signed and does not require signature on all pages
Report Number: 4791164272.5.1-OTHER-S1
Disclaimer
The issuance of this report in no way implies Listing, Classification or Recognition by UL and does not authorize the use of UL Listing, Classification or Recognition Marks or
any other reference to UL on the product or system. UL authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. UL's name or
marks cannot be used in any packaging, advertising, promotion or marketing relating to the data in this Report, without UL's prior written permission. The results of testing in
this report apply only to the sample product/item, which was tested. UL Lab has not participated in the sample. Other similar sample will not necessarily produce the same
results due to production tolerance and measurement uncertainties. The laboratory is not responsible when the information is supplied by the customer and can affect the
validity of results. The applicable standard ambient condition supersedes the lab general ambient conditions and are recorded in datasheets available in the lab. Decision rule
for statement(s) of conformity is based on IEC Guide 115:2023, Clause 4.3.3 Simple Acceptance. Measurement uncertainty is not applied when providing statements of
conformity in accordance with IEC Guide 115: 2023, Clause 4.3.3.
Page 3 of 11
This document is digitally signed and does not require signature on all pages
Report Number: 4791164272.5.1-OTHER-S1
1) The below got test results in this report will relate only to the items tested.
2) This report shall not be reproduced except in full, without the written approval of the testing laboratory.
1 THE MEASUREMENT OF
INCIDENCE ANGLE IEC 61853-2, clause
6934287 Refer test table results
EFFECTS (INDOOR TEST 7.2
METHOD)
P: Meets the requirements F: Does not meet the requirement NA: Not applicable
Page 4 of 11
This document is digitally signed and does not require signature on all pages
Report Number: 4791164272.5.1-OTHER-S1
Page 5 of 11
This document is digitally signed and does not require signature on all pages
Report Number: 4791164272.5.1-OTHER-S1
Indoor test method: The test shall be performed as per Clause 7.2 of IEC 61853-2.
Test Results
Ambient Temperature, C 25.1 Relative Humidity, % 45.0
Model: RS580144TGC
Sample No. 6934287
Test date: 2024-03-15
Page 6 of 11
This document is digitally signed and does not require signature on all pages
Report Number: 4791164272.5.1-OTHER-S1
-20 0.349 6.272 6.271 6.272 25.0 25.0 25.0 1000.0 1000.1 1000.1 6.272 1.000
-30 0.524 5.790 5.789 5.788 25.0 25.0 25.0 1000.0 1000.0 1000.0 5.789 1.002
-40 0.698 5.112 5.114 5.115 25.0 25.0 25.0 1000.0 1000.0 1000.1 5.114 1.000
-50 0.873 4.279 4.276 4.279 25.0 25.0 25.0 1000.0 1000.1 1000.0 4.278 0.998
-60 1.047 3.257 3.258 3.256 25.0 25.0 25.0 1000.0 1000.0 1000.0 3.257 0.976
-65 1.134 2.703 2.703 2.704 25.1 25.1 25.0 1000.0 1000.1 1000.0 2.703 0.957
-70 1.222 2.105 2.105 2.103 25.0 25.1 25.1 1000.1 1000.1 1000.1 2.104 0.923
-75 1.309 1.471 1.470 1.471 25.0 25.1 25.1 1000.1 1000.1 1000.1 1.471 0.851
-80 1.396 0.871 0.871 0.871 25.0 25.0 25.0 1000.1 1000.1 1000.1 0.871 0.750
-85 1.484 0.356 0.357 0.357 25.1 25.0 25.0 1000.0 1000.1 1000.0 0.357 0.616
-90 1.571 0.000 0.000 0.000 - - - - - - 0.000 0.000
0 0 6.675 6.674 6.675 25.2 24.7 25.1 1000.0 1000.0 1000.0 6.675 -
ar value 0.1112030
Estimated Standard Error 0.0043081
Expanded MU (k=2, confidence level of 95%) 0.0086162
Page 7 of 11
This document is digitally signed and does not require signature on all pages
Report Number: 4791164272.5.1-OTHER-S1
Interpolation of angular
transmission model Ashrae model
C1 C2
θ τ(θ)
90 0.000 0 1.000
85 0.543
80 0.790
75 0.903 30 0.992
70 0.954
65 0.978 50 0.972
60 0.989 60 0.950
50 0.997
40 0.999 70 0.904
30 1.000 75 0.857
20 1.000 80 0.762
10 1.000 85 0.476
0 1.000 90 0.000
-10 1.000
-20 1.000
-30 1.000
-40 0.999
-50 0.997
-60 0.989
-65 0.978
-70 0.954
-75 0.903
-80 0.790
-85 0.543
-90 0.000
Page 8 of 11
This document is digitally signed and does not require signature on all pages
Report Number: 4791164272.5.1-OTHER-S1
Regression results:
Page 9 of 11
This document is digitally signed and does not require signature on all pages
Report Number: 4791164272.5.1-OTHER-S1
Page 10 of 11
This document is digitally signed and does not require signature on all pages
Report Number: 4791164272.5.1-OTHER-S1
Appendix
Bill of Materials Details (as declared by the Manufacturer):
Type :
Manufactured by: Tongwei Solar Co., Ltd.
M182GBTCONBP,N-Type TopCon
10 Cell (TONGWEI)
(Mono)
******End of Report******
Page 11 of 11
This document is digitally signed and does not require signature on all pages