Relative Humidity Humidity
Relative Humidity Humidity
Outside Air/Euro
RELATIVE HUMIDITY
Humidity Transmitter
The A/RH Series relative humidity transmitters utilize a capacitive sensing element to deliver a
proportional analog output. This series features on board DIP switches which allow the user to
select the desired output signal. In addition, field calibration can be performed by using the on board
increment and decrement DIP switches. Duct and Outside Air configurations feature conformally coated
circuit boards for moisture resistance. These enhancements provide increased flexibility and outstanding
long-term performance.
The A/RH Series is covered by ACI's Five (5) Year Limited Warranty. The warranty can be found in the
front of ACI's Sensors & Transmitters catalog, as well as on ACI's web site, www.workaci.com.
SPECIFICATIONS
RH Supply Voltage (4 to 20 mA) (250 Ohm Load): 15 to 40 VDC/18 to 28 VAC
RH Supply Voltage (4 to 20 mA) (500 Ohm Load): 18 to 40 VDC/18 to 28 VAC
RH Supply Voltage (0-5 VDC) 12 to 40 VDC/18 to 28 VAC (4K Load minimum)
RH Supply Voltage (0-10 VDC) 18 to 40 VDC/18 to 28 VAC (4K Load minimum)
Supply Current Voltage Output: 8 mA maximum | Current Output: 24 mA maximum
RH Measurement Range 0-100%
RH Output 2-wire: 4 to 20 mA (Factory Standard) | 3-wire: 0-5, 0-10 VDC or 4 to 20 mA
Accuracy @ 77oF (25oC) +/- 1% over 20% span (between 20 to 90%) | +/- 2%, 3%, or 5% from 10 to 95%
Long Term Stability Less than 2% drift/5 years
Repeatablity 0.5% RH
Sensitivity 0.1% RH
Operating Environment (Duct) Duct/Outside: 0 to 100 % RH | -40 to 140oF (-40 to 60oC)
Operating Environment (Room) Room: 0 to 95% RH (non-condensing) | 32 to 122oF (0 to 50oC)
RH Sensor Type Capacitive
Product Dimensions (Duct/Euro) Enclosure: (W) 3.60” (D) 2.25” | Probe: (L) 7.15”
Product Dimensions (Outside Air) Cover: (H) 3.61” (W) 4.00” (D) 2.25” | Stem: (H) 3.00” (W) 1.13”
Product Dimensions (Room 2) (H) 4.50” (W) 2.75” (D) 1.12”
Product Dimensions (Room) (H) 4.51” (W) 2.75” (D) 2.90”
Product Dimensions (Stainless Plate) Plate: (H) 4.51” (W) 2.76” (D) 0.19” | Filter: (L) 1.06”
ORDERING
Select one Series (A). If A/RH1 is selected, you must specify a 20% range. Choose one Configuration (B) and one Output (C). NOTE: 4 to 20 mA
output is not available for the SP configuration.
A/RH1 (+/-1%) (Specify a 20% Range) D (Duct/Euro) ---- (4 to 20 mA) (Field selectable output to 0-5 VDC or 0-10 VDC)
A/RH2 (+/-2%) O (Outside Air/Euro) 5 (0 to 5 VDC) (Field selectable output to 0-10 VDC or 4 to 20 mA)
A/RH3 (+/-3%) SP (Stainless Plate) 10 (0 to 10 VDC) (Field selectable output to 4 to 20 mA or 0-5 VDC)
A/RH5 (+/-5%) R2 (Room, New Enclosure)
R (Room, Previous Enclosure)
EXAMPLE: A/RH3 - D - 10
36 1-888-967-5224 www.workaci.com