0% found this document useful (0 votes)
6 views776 pages

Dell SNMP

The document is the SNMP Reference Guide for Dell OpenManage Server Administrator, detailing supported SNMP versions and various Management Information Bases (MIBs) related to server management. It includes sections on instrumentation, system management software, system state, chassis information, and more, providing technical terms and variable values. The guide is intended for users to better utilize the server management capabilities of Dell's software.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views776 pages

Dell SNMP

The document is the SNMP Reference Guide for Dell OpenManage Server Administrator, detailing supported SNMP versions and various Management Information Bases (MIBs) related to server management. It includes sections on instrumentation, system management software, system state, chassis information, and more, providing technical terms and variable values. The guide is intended for users to better utilize the server management capabilities of Dell's software.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 776

book.

book Page 1 Monday, March 14, 2011 3:01 PM

Dell OpenManage
Server Administrator
SNMP Reference Guide
book.book Page 2 Monday, March 14, 2011 3:01 PM

Notes and Cautions


NOTE: A NOTE indicates important information that helps you make better use of
your computer.
A CAUTION indicates potential damage to hardware or loss of data if instructions
are not followed.

__________________
Information in this publication is subject to change without notice.
© 2003–2011 Dell Inc. All rights reserved.
Reproduction of these materials whatsoever without the written permission of Dell Inc. is strictly
forbidden.
Trademarks used in this text: Dell™, the DELL™ logo, PowerEdge™, PowerVault™, and
OpenManage™ are trademarks of Dell Inc. Microsoft® and Windows® are either trademarks or
registered trademarks of Microsoft Corporation in the United States and/or other countries. Intel®,
Itanium®, Pentium®, Atom®, and Celeron® are registered trademarks, and MMX™, Xeon™, and
Core™ are trademarks of Intel Corporation in the United States and/or other countries. VESA® is a
registered trademark of the Video Electronics Standards Association. AMD™, AMD Athlon™, AMD
Opteron™, AMD Sempron™, AMD Turion™, AMD Phenom™, and AMD Duron™ are trademarks
of Advanced Micro Devices, Inc. VIA C7™ and VIA Eden™ are either trademarks or registered
trademarks of VIA Technology, Inc. Crusoe™ and Efficeon™ are trademarks of Transmeta
Corporation in the USA and other countries.
Other trademarks and trade names may be used in this document to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.

2011 - 3
book.book Page 3 Monday, March 14, 2011 3:01 PM

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . 15
Supported SNMP Versions . . . . . . . . . . . . . . . 15

Introduction to the SNMP Reference Guide . . . . . . 16


Server Administrator Instrumentation MIB . . . . 17
Server Administrator Remote Access MIB . . . . 20
Server Administrator Baseboard Management
Controller, ASF MIB . . . . . . . . . . . . . . . . 20
Server Administrator Field Replaceable
Unit MIB . . . . . . . . . . . . . . . . . . . . . . 20
Server Administrator Storage Management
MIB . . . . . . . . . . . . . . . . . . . . . . . . . 21
Server Administrator Change Management
MIB . . . . . . . . . . . . . . . . . . . . . . . . . 22
Dell Remote Access Controller Out-of-Band
MIB . . . . . . . . . . . . . . . . . . . . . . . . . 23
How This Guide Defines Technical Terms . . . . . 23
SNMP Basic Terminology . . . . . . . . . . . . . 24
Frequently Used Terms in Variable Names . . . . 27
Tables . . . . . . . . . . . . . . . . . . . . . . . 28
Section Organization . . . . . . . . . . . . . . . . 31
Other Documents You May Need . . . . . . . . . 32

Introduction to the Server Administrator SNMP


Subagent . . . . . . . . . . . . . . . . . . . . . . . . . 32
SNMP Management Information Base Object
Identifiers . . . . . . . . . . . . . . . . . . . . . 34
SNMP Security . . . . . . . . . . . . . . . . . . . 35
Management Actions . . . . . . . . . . . . . . . 36
SNMP Traps . . . . . . . . . . . . . . . . . . . . 36

Contents 3
book.book Page 4 Monday, March 14, 2011 3:01 PM

Updates For Dell OpenManage Server


Administrator Version 6.5 . . . . . . . . . 39

2 What’s New in This Release . . . . . . . . . . 39


Device Group . . . . . . . . . . . . . . . . . . . . . . 40
Device Tables . . . . . . . . . . . . . . . . . . . . 40
Network Device Table . . . . . . . . . . . . . . . 40

Device Group Variable Values . . . . . . . . . . . . . 41

Memory Group . . . . . . . . . . . . . . . . . . . . . . 41
Physical Memory Tables . . . . . . . . . . . . . . 41
Physical Memory Configuration Table . . . . . . . 41

Memory Group Variable Values . . . . . . . . . . . . . 42

Storage Management Group . . . . . . . . . . . . . . 44


Physical Devices Group . . . . . . . . . . . . . . 44
Controller Table . . . . . . . . . . . . . . . . . . . 44
Enclosure Table . . . . . . . . . . . . . . . . . . . 45
Array Disk Table . . . . . . . . . . . . . . . . . . 46

3 Instrumentation MIB Version Group . . . . 47


Management Information Base Major Version
Number . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Management Information Base Minor Version


Number . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Management Information Base Maintenance Version


Number . . . . . . . . . . . . . . . . . . . . . . . . . . 48

4 Systems Management Software Group . . 49


Systems Management Software . . . . . . . . . . . . 49

Systems Management Software Variable Values . . . 53

4 Contents
book.book Page 5 Monday, March 14, 2011 3:01 PM

5 System State Group . . . . . . . . . . . . . . . . . 55


System State Group Table . . . . . . . . . . . . . . . . 55
System State Table . . . . . . . . . . . . . . . . . 55
System State Table . . . . . . . . . . . . . . . . . 57

6 Chassis Information Group . . . . . . . . . . . 77


Chassis Information Group Tables . . . . . . . . . . . 77
Chassis Information Table . . . . . . . . . . . . . 77
UUID Table . . . . . . . . . . . . . . . . . . . . . 90
POST Log Table . . . . . . . . . . . . . . . . . . . 92
Event Log Table . . . . . . . . . . . . . . . . . . . 94
System BIOS Table . . . . . . . . . . . . . . . . . 97
Firmware Table . . . . . . . . . . . . . . . . . . . 104
Intrusion Table . . . . . . . . . . . . . . . . . . . 107
Baseboard Table . . . . . . . . . . . . . . . . . . 109

Chassis Information Group Variable Values . . . . . . 114

7 Operating System Group . . . . . . . . . . . . 129


Operating System Group Table . . . . . . . . . . . . . 129
Operating System Table . . . . . . . . . . . . . . 129
Operating System Memory Table . . . . . . . . . 131

8 System Resource Group . . . . . . . . . . . . 135


System Resource Group Tables . . . . . . . . . . . . . 135
System Resource Map Table . . . . . . . . . . . . 135
System Resource Owner Table . . . . . . . . . . 137
System Resource Input/Output (I/O) Port Table . . 140
System Resource Memory Table . . . . . . . . . . 143
System Resource Interrupt Table . . . . . . . . . 146

Contents 5
book.book Page 6 Monday, March 14, 2011 3:01 PM

System Resource Direct Memory Access (DMA)


Table . . . . . . . . . . . . . . . . . . . . . . . . 149

System Resource Group Variable Values . . . . . . . . 152

9 Power Group . . . . . . . . . . . . . . . . . . . . . 157


Power Group Tables . . . . . . . . . . . . . . . . . . . 157
Power Unit Table . . . . . . . . . . . . . . . . . . 157
Power Supply Table . . . . . . . . . . . . . . . . 160
Voltage Probe Table . . . . . . . . . . . . . . . . 164
Amperage Probe Table . . . . . . . . . . . . . . . 169
AC Power Switch Table . . . . . . . . . . . . . . 175
AC Power Cord Table . . . . . . . . . . . . . . . . 177
Battery Table . . . . . . . . . . . . . . . . . . . . 180
Power Usage Table . . . . . . . . . . . . . . . . . 182
Power Profile Table . . . . . . . . . . . . . . . . . 188

Power Group Variable Values . . . . . . . . . . . . . . 191

10 Thermal Group . . . . . . . . . . . . . . . . . . . . 205


Thermal Group Tables . . . . . . . . . . . . . . . . . . 205
Cooling Unit Table . . . . . . . . . . . . . . . . . 205
Cooling Device Table . . . . . . . . . . . . . . . . 208
Temperature Probe Table . . . . . . . . . . . . . 213

Thermal Group Variable Values . . . . . . . . . . . . . 219

11 User Security Group . . . . . . . . . . . . . . . 223


User Security Group Table . . . . . . . . . . . . . . . 223
User Security Table . . . . . . . . . . . . . . . . . 223

6 Contents
book.book Page 7 Monday, March 14, 2011 3:01 PM

12 Remote Flash BIOS Group . . . . . . . . . . . 227


Remote Flash BIOS Group Table . . . . . . . . . . . . 227
Remote Flash BIOS Table . . . . . . . . . . . . . 227

Remote Flash BIOS Variable Values . . . . . . . . . . 230

13 Port Group . . . . . . . . . . . . . . . . . . . . . . . 233


Port Group Tables . . . . . . . . . . . . . . . . . . . . 233
Pointing Port Table . . . . . . . . . . . . . . . . . 233
Keyboard Port Table . . . . . . . . . . . . . . . . 236
Processor Port Table . . . . . . . . . . . . . . . . 239
Memory Device Port Table . . . . . . . . . . . . . 242
Monitor Port Table . . . . . . . . . . . . . . . . . 245
Small Computer System Interface (SCSI) Port
Table . . . . . . . . . . . . . . . . . . . . . . . . 248
Parallel Port Table . . . . . . . . . . . . . . . . . 250
Serial Port Table . . . . . . . . . . . . . . . . . . 254
Universal Serial Bus (USB) Port Table . . . . . . . 258

Port Group Variable Values . . . . . . . . . . . . . . . 261

14 Device Group . . . . . . . . . . . . . . . . . . . . 267


Device Tables . . . . . . . . . . . . . . . . . . . . . . 267
Pointing Device Table . . . . . . . . . . . . . . . 268
Keyboard Device Table . . . . . . . . . . . . . . . 270
Processor Device Table . . . . . . . . . . . . . . 273
Processor Device Status Table . . . . . . . . . . 281
Cache Device Table . . . . . . . . . . . . . . . . 283
Memory Device Table . . . . . . . . . . . . . . . 289
Memory Device Mapped Address Table . . . . . . 297
Generic Device Table . . . . . . . . . . . . . . . 300
PCI Device Table . . . . . . . . . . . . . . . . . . 303

Contents 7
book.book Page 8 Monday, March 14, 2011 3:01 PM

PCI Device Configuration Space Table . . . . . . . 306


Network Device Table . . . . . . . . . . . . . . . 309
Managed System Services Device Table . . . . . 317
SD Card Unit Table . . . . . . . . . . . . . . . . . 319
SD Card Device Table . . . . . . . . . . . . . . . 322

Device Group Variable Values . . . . . . . . . . . . . 326

15 Slot Group . . . . . . . . . . . . . . . . . . . . . . . 355


System Slot Group Table . . . . . . . . . . . . . . . . . 355
System Slot Table . . . . . . . . . . . . . . . . . . 355

System Slot Variable Values . . . . . . . . . . . . . . . 359

16 Memory Group . . . . . . . . . . . . . . . . . . . . 369


Physical Memory Tables . . . . . . . . . . . . . . . . 369
Physical Memory Array Table . . . . . . . . . . . 369
Physical Memory Array Mapped Table . . . . . . 374
Physical Memory Configuration Table . . . . . . . 377
Physical Memory Logging Table . . . . . . . . . . 379
Redundant Memory Unit Table . . . . . . . . . . . 381
Physical Memory Card Table . . . . . . . . . . . . 384

Memory Group Variable Values . . . . . . . . . . . . . 387

17 BIOS Setup Control Group . . . . . . . . . . . 393


BIOS Group Tables . . . . . . . . . . . . . . . . . . . . 393
BIOS Setup Control Table . . . . . . . . . . . . . 393
SCSI Control Table . . . . . . . . . . . . . . . . . 404
Parallel Port Control Table . . . . . . . . . . . . . 406
Serial Port Control Table . . . . . . . . . . . . . . 408
USB Control Table . . . . . . . . . . . . . . . . . 410
IDE Control Table . . . . . . . . . . . . . . . . . . 412

8 Contents
book.book Page 9 Monday, March 14, 2011 3:01 PM

Diskette Control Table . . . . . . . . . . . . . . . 414


Network Interface Control Table . . . . . . . . . . 416

BIOS Group Variable Values . . . . . . . . . . . . . . 419

18 Local Response Agent Group . . . . . . . . 429


LRA Group Tables . . . . . . . . . . . . . . . . . . . . 429
LRA Global Settings . . . . . . . . . . . . . . . . 429
LRA Global Settings Table . . . . . . . . . . . . . 430
LRA Action Table . . . . . . . . . . . . . . . . . . 432

Local Response Agent Variable Values . . . . . . . . . 434

19 Cost of Ownership Group . . . . . . . . . . . 437


Cost of Ownership Group Tables . . . . . . . . . . . . 437
Cost of Ownership Table . . . . . . . . . . . . . . 437
COO Service Contract Table . . . . . . . . . . . . 448
COO Cost Event Log Table . . . . . . . . . . . . . 450
COO Warranty Table . . . . . . . . . . . . . . . . 452
COO Lease Information Table . . . . . . . . . . . 454
COO Schedule Number Table . . . . . . . . . . . 457
COO Options Table . . . . . . . . . . . . . . . . . 458
COO Maintenance Table . . . . . . . . . . . . . . 460
COO Repair Table . . . . . . . . . . . . . . . . . . 462
COO Support Information Table . . . . . . . . . . 464
COO Trouble Ticket Table . . . . . . . . . . . . . 466

Cost of Ownership Variable Values . . . . . . . . . . . 468

20 Remote Access Group . . . . . . . . . . . . . . 471


DRAC 4 and DRAC 5 . . . . . . . . . . . . . . . . . . . 471
Remote Access Table . . . . . . . . . . . . . . . 471

Contents 9
book.book Page 10 Monday, March 14, 2011 3:01 PM

DRAC III . . . . . . . . . . . . . . . . . . . . . . . . . 477


Remote Access Table . . . . . . . . . . . . . . . 478
Remote User Administration Table . . . . . . . . . 487
Remote SNMP Trap Table . . . . . . . . . . . . . 495
Remote Dial-Up Table . . . . . . . . . . . . . . . 500
Remote User Dial-In Configuration Table . . . . . 504
Remote Dial-Out Table . . . . . . . . . . . . . . . 507

Remote Access Variable Values . . . . . . . . . . . . 510

21 Cluster Group . . . . . . . . . . . . . . . . . . . . 527


Cluster Group . . . . . . . . . . . . . . . . . . . . . . 527
Cluster Table . . . . . . . . . . . . . . . . . . . . 527

Cluster Group Variable Values . . . . . . . . . . . . . 530

22 Baseboard Management Controller


Group . . . . . . . . . . . . . . . . . . . . . . . . . . 531
Baseboard Management Controller Group Tables . . . 531
Baseboard Management Controller Table . . . . . 531
Baseboard Management Controller Serial Interface
Table . . . . . . . . . . . . . . . . . . . . . . . . 535
Baseboard Management Controller LAN Interface
Table . . . . . . . . . . . . . . . . . . . . . . . . 539

Baseboard Management Controller Group Variable


Values . . . . . . . . . . . . . . . . . . . . . . . . . . 543

23 Field Replaceable Unit Group . . . . . . . . 547


Field Replaceable Unit Group Tables . . . . . . . . . . 547
Field Replaceable Unit Table . . . . . . . . . . . . 547

Field Replaceable Unit Group Variable Values . . . . . 551

10 Contents
book.book Page 11 Monday, March 14, 2011 3:01 PM

24 Storage Management Group . . . . . . . . . 553


Storage Management Group . . . . . . . . . . . . . . 553

Storage Management Information Group . . . . . . . . 555

Global Data Group . . . . . . . . . . . . . . . . . . . . 556

Physical Devices Group . . . . . . . . . . . . . . . . . 562


Controller Table . . . . . . . . . . . . . . . . . . 563
Channel Table . . . . . . . . . . . . . . . . . . . 583
Enclosure Table . . . . . . . . . . . . . . . . . . 588
Array Disk Table . . . . . . . . . . . . . . . . . . 599
Array Disk Enclosure Connection Table . . . . . . 613
Array Disk Channel Connection Table . . . . . . . 615
Fan Table . . . . . . . . . . . . . . . . . . . . . . 618
Fan Connection Table . . . . . . . . . . . . . . . 624
Power Supply Table . . . . . . . . . . . . . . . . 626
Power Supply Connection Table . . . . . . . . . . 631
Temperature Probe Table . . . . . . . . . . . . . 633
Temperature Probe Connection Table . . . . . . . 638
Enclosure Management Module Table . . . . . . 640
Enclosure Management Module Connection Table 645
Battery Table . . . . . . . . . . . . . . . . . . . . 648
Battery Connection Table . . . . . . . . . . . . . 654

Logical Devices Group . . . . . . . . . . . . . . . . . 656


Virtual Disk Table . . . . . . . . . . . . . . . . . . 656
Array Disk Logical Connection Table . . . . . . . 666

Storage Management Event Group . . . . . . . . . . . 669

25 Change Management Group . . . . . . . . . 673


Inventory Group . . . . . . . . . . . . . . . . . . . . . 673

Device Group . . . . . . . . . . . . . . . . . . . . . . 674


Device Group Table . . . . . . . . . . . . . . . . 674

Contents 11
book.book Page 12 Monday, March 14, 2011 3:01 PM

Application Group . . . . . . . . . . . . . . . . . . . . 676


Application Group Table . . . . . . . . . . . . . . 677

Operating System Group . . . . . . . . . . . . . . . . . 679

Inventory Collector Product Information . . . . . . . . 680

26 Dell Remote Access Controller


Out-of-Band Group . . . . . . . . . . . . . . . . 683
Product Information . . . . . . . . . . . . . . . . . . . 683

Chassis Status . . . . . . . . . . . . . . . . . . . . . . 687


DRsCMCChangeTime . . . . . . . . . . . . . . . . 696

Chassis Power . . . . . . . . . . . . . . . . . . . . . . 697

CMC Power Information . . . . . . . . . . . . . . . . . 698

CMC PSU Information . . . . . . . . . . . . . . . . . . 702

Chassis Alerts . . . . . . . . . . . . . . . . . . . . . . 704

Legacy Alerting . . . . . . . . . . . . . . . . . . . . . 706

27 Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . 709
Trap Variables . . . . . . . . . . . . . . . . . . . . . . 710

Understanding the Trap Description . . . . . . . . . . 711

Understanding Trap Severity . . . . . . . . . . . . . . 716

Instrumentation Traps . . . . . . . . . . . . . . . . . . 716


Miscellaneous Traps . . . . . . . . . . . . . . . . 716
Temperature Probe Traps . . . . . . . . . . . . . 718
Cooling Device Traps . . . . . . . . . . . . . . . . 721
Voltage Probe Traps . . . . . . . . . . . . . . . . 723
Amperage Probe Traps . . . . . . . . . . . . . . . 725
Chassis Intrusion Traps . . . . . . . . . . . . . . 728
Redundancy Unit Traps . . . . . . . . . . . . . . . 729

12 Contents
book.book Page 13 Monday, March 14, 2011 3:01 PM

Power Supply Traps . . . . . . . . . . . . . . . . 731


Memory Device Traps . . . . . . . . . . . . . . . 733
Fan Enclosure Traps . . . . . . . . . . . . . . . . 734
AC Power Cord Traps . . . . . . . . . . . . . . . 735
Hardware Log Traps . . . . . . . . . . . . . . . . 736
Processor Device Status Traps . . . . . . . . . . 737
Pluggable Device Traps . . . . . . . . . . . . . . 739
Battery Traps . . . . . . . . . . . . . . . . . . . . 740
SD Card Device Traps . . . . . . . . . . . . . . . 742

RAC Traps . . . . . . . . . . . . . . . . . . . . . . . . 743

BMC Traps . . . . . . . . . . . . . . . . . . . . . . . . 749

28 Storage Management Alert


Reference 755
Alert Monitoring and Logging . . . . . . . . . . . . . . 755

Viewing Alerts . . . . . . . . . . . . . . . . . . . . . 756

Alert Severity Levels . . . . . . . . . . . . . . . . . . 756

SNMP Support for Storage Management Alerts . . . . 757


SNMP Trap Forwarding . . . . . . . . . . . . . . 757
SNMP Trap Definitions . . . . . . . . . . . . . . . 758
SNMP Trap Variables . . . . . . . . . . . . . . . 758

Viewing SNMP Traps . . . . . . . . . . . . . . . . . . 759

Alert Descriptions and Corrective Actions . . . . . . . 759

A Standard Data Type Definitions . . . . . . 761


Common Data Types . . . . . . . . . . . . . . . . . . . 761

Variables with Data Types of State Capabilities and


State Capabilities Unique . . . . . . . . . . . . . . . . 762

Contents 13
book.book Page 14 Monday, March 14, 2011 3:01 PM

Dell Status Data Types . . . . . . . . . . . . . . . . . . 764

Dell Date . . . . . . . . . . . . . . . . . . . . . . . . . 765


Full Dates . . . . . . . . . . . . . . . . . . . . . . 766

B SNMP Sample Output . . . . . . . . . . . . . . 767

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 773

14 Contents
book.book Page 15 Monday, March 14, 2011 3:01 PM

1
Introduction
This reference guide provides information about the Simple Network
Management Protocol (SNMP) Management Information Base (MIB) which
is applicable for Dell OpenManage Version 6.4.
NOTE: This guide contains information that may also be applicable to earlier
OpenManage supported platforms.
This introduction is divided into two sections. The first section,
"Introduction to the SNMP Reference Guide" on page 16, explains the SNMP
Reference Guide design. All essential Simple Network Management Protocol
(SNMP) terms are defined in this section. Some of the vocabulary may seem
complex and unfamiliar to system administrators who are using SNMP for the
first time. SNMP experts can skim this section, and beginners can read the
section more carefully.
The second section, "Introduction to the Server Administrator
SNMP Subagent" on page 32, is a more technical introduction to the
management information base (MIB) that underlies Server Administrator
services.

Supported SNMP Versions


Operating System Supported SNMP version
Windows SNMP v1 and v2c
Linux SNMP v1, v2c, and v3

Introduction 15
book.book Page 16 Monday, March 14, 2011 3:01 PM

Introduction to the SNMP Reference Guide


This reference guide provides a formatted version of the following
Management Information Base that are released with the current version of
Dell OpenManage.

Management Information Base (MIB) Management Information Base (MIB)


Name Filename
Server Administrator Instrumentation 10892.mib
MIB
Remote Access MIB dcs3rmt.mib
Server Administrator Field Replaceable dcs3fru.mib
Unit MIB
Server Administrator Storage dcstorag.mib
Management MIB
Server Administrator Change dellcm.mib
Management MIB
Dell RAC Out-of-Band MIB dellRAC.mib

Sections in this guide follow MIB groups and provide explanations and
definitions for the terms used to define MIB objects. Content in this reference
guide is organized as documented in the following subsections.
General Content
Table 1-1 describes the sections that provide general information about the
MIBs documented in this guide.
Table 1-1. General Content Sections in This Guide

Section Topics MIB Group


Number
1 Introduction to SNMP basics and to the MIBs that NA
support Server Administrator services
26 Traps — describes in-band traps defined in the Server 5000
Administrator Instrumentation MIB and out-of-band
traps sent by the Remote Access Controller (RAC)
and Baseboard Management Controller (BMC).

16 Introduction
book.book Page 17 Monday, March 14, 2011 3:01 PM

Table 1-1. General Content Sections in This Guide (continued)

Section Topics MIB Group


Number
Appendix A Standard Data Type Definitions — defines standard NA
data types used in this reference guide.
Appendix B SNMP Sample Output — provides a sample SNMP NA
output.

Server Administrator Instrumentation MIB


The Server Administrator Instrumentation MIB (filename 10892.mib) provides
instrumentation data that allows you to monitor the health of a system with
SNMP management applications. It provides:
• Information about the status of temperatures, power supplies, voltages,
currents, fans, and memory at key points in the system
• Rapid access to detailed fault and performance information gathered by
industry standard systems management agents
• Version information for Basic Input/Output System (BIOS), firmware,
and operating system
• A detailed account of every cost of ownership (COO) detail about your system
In addition, traps are sent to report a change in status of the health of critical
components.
The Server Administrator Instrumentation MIB structures its MIB objects
into groups of scalar objects or MIB tables that provide related information.
Table 1-2 describes each Server Administrator Instrumentation MIB group
and lists the MIB group number assigned to the MIB group.
The Server Administrator Instrumentation MIB groups are identified
by the SNMP OID 1.3.6.1.4.1.674.10892.1.<MIB group number>,
where <MIB group number> is the MIB group number assigned to the
MIB group. See the relevant section for more information about the
MIB objects defined in a MIB group.

Introduction 17
book.book Page 18 Monday, March 14, 2011 3:01 PM

Table 1-2. Server Administrator Instrumentation MIB Sections in This Guide

Section Topics MIB Group


Numbers
2 Instrumentation MIB Version Group — defines version 1
numbers of the Instrumentation MIB
3 Systems Management Software Group — defines information 100
about the systems management software and the supported
systems management standards
4 System State Group — defines status, state, and redundancy for 200
a system and its components
5 Chassis Information Group — defines chassis types, events, and 300
indicators
6 Operating System Group — defines variables for name, version, 400
service pack, and other information about a system’s operating
system
7 System Resource Group — defines variables for input/output 500
ports, memory, interrupts, and direct memory access
8 Power Group — defines variables for power units, power 600
supplies, and their current and voltage probes
9 Thermal Group — defines variables for temperature probes and 700
cooling devices
10 User Security Group — defines variables for creating and 800
modifying user accounts
11 Remote Flash BIOS Group — defines variables for updating the 900
system’s BIOS remotely
12 Port Group — defines variables for major port types such as 1000
keyboard, monitor, small computer system interface (SCSI),
Universal Serial Bus (USB), and parallel and serial ports
13 Device Group — defines variables for pointing, keyboard, 1100
processor, cache, memory, and personal computer interface
devices
14 Slot Group — defines variables for the system’s slots 1200
15 Memory Group — defines variables for the system’s 1300
physical memory

18 Introduction
book.book Page 19 Monday, March 14, 2011 3:01 PM

Table 1-2. Server Administrator Instrumentation MIB Sections in This Guide

Section Topics MIB Group


Numbers
16 BIOS Setup Control Group — defines variables for BIOS 1400
functions such as boot sequence, speakers, Wake on the local
area network (LAN), diskettes, ports, and
network interface controllers (NIC)
17 Local Response Agent Group — defines variables for global 1500
settings and actions. These variables allow users to
predetermine how the system responds to a particular
type of event
18 Cost of Ownership Group — defines variables for tracking data 1600
on the system’s service contract, lease, repair records, trouble
tickets, and so on
20 Cluster Group — defines variables for systems that operate as a 1800
cluster
21 Baseboard Management Controller Group — provides 1900
information about the Baseboard Management Controller
(BMC) that may be present in your system. In addition to
providing general information about the BMC, this group
provides information about the serial and local area network
(LAN) interfaces of the BMC
26 Traps — defines the types of alerts that can be sent to report the 5000
status of critical components

Introduction 19
book.book Page 20 Monday, March 14, 2011 3:01 PM

Server Administrator Remote Access MIB


The Server Administrator Remote Access MIB (filename dcs3rmt.mib)
provides in-band information about remote access hardware that may be
present in your system.
The Server Administrator Remote Access MIB structures its MIB objects into
groups of scalar objects or MIB tables that provide related information.
Table 1-3 describes each Server Administrator Remote Access MIB group and
lists the MIB group number assigned to the MIB group. The Server
Administrator Remote Access MIB groups are identified by the SNMP OID
1.3.6.1.4.1.674.10892.1.<MIB group number> where <MIB group number> is
the MIB group number assigned to the MIB group. See the relevant section
for more information about the MIB objects defined in a MIB group.

Table 1-3. Server Administrator Remote Access MIB Sections in This Guide

Section Topic MIB Group


Numbers
19 Remote Access Group — provides information about remote 1700
access hardware that may be present in your system and defines
variables for administrative users, SNMP trap destinations,
modem configuration for dial-up networking, dial-in
configuration, and dial-out destinations

Server Administrator Baseboard Management Controller, ASF MIB


The Server Administrator BMC MIB (filename DcAsfSrv.mib) provides
information about the traps sent by BMC. The Server Administrator BMC
MIB structures its MIB objects that provide related information. The BMC
MIB groups are identified by the SNMP OID 1.3.6.1.4.1.3183.1.1.<MIB
group number>. The BMC MIB adheres to ASF 2.0 standard and hence the
enterprise ID is wired for management (3183).

Server Administrator Field Replaceable Unit MIB


The Server Administrator Field Replaceable Unit MIB (filename
dcs3fru.mib) provides information about field replaceable unit (FRU)
hardware that may be present in your system.

20 Introduction
book.book Page 21 Monday, March 14, 2011 3:01 PM

The Server Administrator Field Replaceable Unit MIB structures its MIB
objects into groups of scalar objects or MIB tables that provide related
information. Table 1-4 describes each Server Administrator Field Replaceable
Unit MIB group and lists the MIB group number assigned to the MIB group.
The Server Administrator Field Replaceable Unit MIB groups are identified
by the SNMP OID 1.3.6.1.4.1.674.10892.1.<MIB group number> where
<MIB group number> is the MIB group number assigned to the MIB group.
See the relevant section for more information about the MIB objects defined
in a MIB group.

Table 1-4. Server Administrator Field Replaceable Unit MIB Sections in This Guide

Section Topic MIB Group


Numbers
22 Field Replaceable Unit Group — provides information about 2000
field replaceable units that may be present in your system

Server Administrator Storage Management MIB


The Server Administrator Storage Management MIB (filename dcstorag.mib)
provides storage management data that allows you to monitor the health of
storage resources with SNMP management applications.
Table 1-5 describes each Server Administrator Storage Management MIB
group and lists the MIB group number assigned to the MIB group. The Server
Administrator Storage Management MIB groups are identified by the SNMP
OID 1.3.6.1.4.1.674.<MIB group number> where <MIB group number> is
the MIB group number assigned to the MIB group. See the relevant section
for more information about the MIB objects defined in a MIB group.

Introduction 21
book.book Page 22 Monday, March 14, 2011 3:01 PM

Table 1-5. Server Administrator Storage Management MIB Sections in This Guide

Section Topics MIB Group


Numbers
23 Storage Management Group — consists of definitions for the 10893
following MIB groups:
• Storage Management Group
• Storage Management Information Group
• Global Data Group
• Physical Devices Group
• Logical Devices Group
• Storage Management Event Group
27 Storage Management Alert Reference — lets you monitor the NA
health of storage resources such as controllers, connectors,
array disks, and virtual disks

Server Administrator Change Management MIB


The Server Administrator Change Management MIB (filename dellcm.mib)
provides management data that allows you to monitor the inventory of devices
and applications with SNMP management applications.
Table 1-6 describes each Server Administrator Change Management MIB
group and lists the MIB group number assigned to the MIB group. The Server
Administrator Change Management MIB groups are identified by the SNMP
OID 1.3.6.1.4.1.674.<MIB group number> where <MIB group number> is
the MIB group number assigned to the MIB group. See the relevant section
for more information about the MIB objects defined in a MIB group.

Table 1-6. Server Administrator Change Management MIB Sections in This Guide

Section Topics MIB Group


Number
24 Change Management Group - describes the inventory data 10899
provided by the Change Management MIB that allows users
to monitor devices and software present on a particular
managed computer chassis

22 Introduction
book.book Page 23 Monday, March 14, 2011 3:01 PM

Dell Remote Access Controller Out-of-Band MIB


The Dell Remote Access Controller Out-of-Band MIB (filename
dellRAC.mib) provides management data that allows you to monitor the
Chassis Management Controller. This MIB also contains information on RAC
legacy alerting. Table 1-7 describes each Dell RAC Out-of-Band group and
lists the MIB group number assigned to the MIB group. See the relevant
section for more information about the MIB objects defined in a MIB group.

Table 1-7. Dell RAC Out-of-Band MIB


Section Topics MIB Group
Number
25 The Dell RAC Out-of-Band MIB consists of information for 2
the following groups:
• "Product Information" on page 683
• "Chassis Status" on page 687
• "Chassis Power" on page 697
• "CMC Power Information" on page 698
• "CMC PSU Information" on page 702
• "Chassis Alerts" on page 704
• "Legacy Alerting" on page 706

How This Guide Defines Technical Terms


The following table provides information about where to find definitions for
technical terms in this reference guide.

Table 1-8. Where to Find Definitions for Technical Terms

Type of Definition See


Basic SNMP vocabulary. "Introduction" on page 15
MIB-group-specific variable values. Sections 3, 5, 7, 8, 9, and 11
MIB-group-specific MIB variables contain links to the through 18.
tables that define these values in the last section of
the section in which these variables are used.
Systems management terms, acronyms, and Glossary available on the Dell
commonly managed components referred to in this Support website at
reference guide. support.dell.com/manuals.

Introduction 23
book.book Page 24 Monday, March 14, 2011 3:01 PM

Table 1-8. Where to Find Definitions for Technical Terms (continued)

Type of Definition See


Server Administrator-standard data types that specify Appendix A, "Standard Data
variable values in this reference guide. Type Definitions" on
page 761.

SNMP Basic Terminology


It is important to have a good understanding of the key technical terms used
in this guide. This guide provides definitions for all essential terms used in
describing the Server Administrator MIBs. For definitions on all essential
terms and acronyms, see the Glossary available on the Dell Support website at
support.dell.com/manuals.

SNMP Master Agent


Typically, the SNMP agent on a managed system consists of one SNMP
master agent and zero or more SNMP extension agents. This SNMP agent
extendable structure facilitates the addition of new MIB modules without
having to rebuild the entire SNMP agent and is invisible to
SNMP management applications.
The SNMP master agent is responsible for receiving SNMP request protocol
messages from SNMP management applications and sending SNMP response
protocol messages. As part of processing SNMP request protocol messages,
the SNMP master agent typically communicates with one or more SNMP
extension agents. This communication does not involve standard SNMP
protocol messages. The SNMP master agent uses an extension protocol that
shields the SNMP extension agent from the standard SNMP protocol
messages. The extension protocol also provides a way for SNMP extension
agents to send SNMP event notifications (called traps in SNMPv1).
The SNMP master agent is also responsible for sending SNMP event
notification protocol messages to SNMP management applications.
On supported operating systems, the SNMP master agent is provided with
the operating system. For example, on supported Microsoft Windows
operating systems, the Windows SNMP service is the SNMP master agent.
For information on the versions of the SNMP protocol supported by the
SNMP master agent, see the operating system documentation.

24 Introduction
book.book Page 25 Monday, March 14, 2011 3:01 PM

SNMP Extension Agent


The SNMP extension agent is responsible for registering the MIB objects that
it supports with the SNMP master agent and then processing requests from
the SNMP master agent for those MIB objects. The SNMP extension agent
also initiates event notifications to the SNMP master agent. The SNMP
extension agent does not receive or send standard SNMP protocol messages.
The SNMP extension agent communicates with the SNMP master agent using
an extension protocol defined by the SNMP master agent. The Server
Administrator SNMP subagent is an SNMP extension agent.

Managed Object
A managed object is any item in a computer system that can be singled out
for discovery, monitoring, or user intervention and correction.
NOTE: Not all managed objects described in this guide are supported by all systems.

MIB
A MIB acts as a structured road map for managed objects. As an Application
Programming Interface (API), a MIB allows systems management tools to
retrieve data maintained by an agent. The server administrator MIB is divided
into several major groups of managed objects.

Variable
A variable is a component of a managed object. A temperature probe, for
example, has a variable to describe its capabilities, its health or status,
and certain indexes that you can use to locate specific temperature probes.
One index for the probe would be the probe’s chassis number. Some systems
may have multiple chassis—one chassis for the central processing unit and
another chassis for storage. A chassis within a system can also have more than
one temperature probe. Variables for a temperature probe include its
capabilities, status, chassis index, and index.

One-Based Index
When an index is one-based, counting starts at 1. One-based indexing counts
the first instance as 1, the second index as 2, and so on.

Introduction 25
book.book Page 26 Monday, March 14, 2011 3:01 PM

Zero-Based Index
When an index is zero-based, counting starts at 0. Zero-based indexing
counts the first instance as 0, the second index as 1, and so on.

Fields
Managed object variables contain fields. In this reference guide, managed
object variables have the following fields defined:
Name is the exact string by which the variable is known in the MIB.
MIB variables are named according to the following conventions:
• Variable names start with a lowercase letter.
• Spaces are not allowed between words in the variable name.
• Acronyms are in uppercase letters, except when an acronym is the first
word in the variable name.
• With the exception of the first letter of the variable name and acronyms,
all other words in the variable name start with capital letters.
The following variable names illustrate these conventions:
• temperatureProbeLowerCriticalThreshold
• coolingUnitIndex
• pCIDeviceSpeed
Object Identifier (OID) is the unique number assigned to an object defined
in a MIB. An OID is written as a sequence of subidentifiers in decimal
notation. Each OID in this reference guide has a prefix that identifies the
managed objects as belonging to Dell: 1.3.6.1.4.1.674. The additional
numbers identify the MIB group and subgroup as well as the table entry
number of any variables.
For example, the OID for the temperature probe managed object table is
700.20 and the variable for the location of the temperature probe
(temperatureProbeLocationName) has an OID of 700.20.1.8. The full OIDs
for these items are 1.3.6.1.4.1.674.10892.1.700.20 for the
temperatureProbeTable and 1.3.6.1.4.1.674.10892.1.700.20.1.8 for the
temperatureProbeLocation. For more information about the structure of
OIDs, see "SNMP Management Information Base Object Identifiers" on
page 34.

26 Introduction
book.book Page 27 Monday, March 14, 2011 3:01 PM

Description is a brief explanation of what a particular managed object does.


Syntax defines the data type in which the values of the variable must be
expressed. Most variables in this reference guide use standard data types such
as string or boolean. All data types that are unique to server administrator
variables are defined at the end of the section in which they occur. Standard
data types are defined in "Standard Data Type Definitions" on page 761.
Access specifies whether persons with administrative privileges can read but not
modify the value of a variable (read only) or can both read and modify the value
of a variable (read-write).

Frequently Used Terms in Variable Names


The following terms are frequently used in the name of a MIB variable:
Capability refers to the actions an object can perform, or to actions that can
be taken by the object. Hot-pluggable is an example of a capability. If a card is
hot-pluggable, it can be replaced while a system is running. Capability settings
refer to the capabilities of the object that the user can select from and activate
if desired. Capability settings allow users of the server administrator to
predetermine how an object behaves under specific conditions.
Settings are the conditions of a manageable object that determine what
happens when a certain value is detected in a component. For example, a user
can set the upper critical threshold of a temperature probe to 75 degrees
Celsius. If the probe reaches that temperature, the setting causes an alert to
be sent to the management console. Some settings, when reached, can trigger
a system shutdown or other response to prevent damage to the system.
State refers to the condition of an object that has more than one condition.
For example, an object may be in a not ready or in an enabled state.
Status refers to the health of an object or how the object is functioning. For
example, the status of a temperature probe that is measuring acceptable
temperatures would be reported as normal. When the probe begins reading
temperatures that exceed limits set by the user, it reports a critical status.

Introduction 27
book.book Page 28 Monday, March 14, 2011 3:01 PM

Tables
This reference guide contains two types of tables: tables that are used to
organize and define variable values and tables that define MIB objects.
Readers must understand the difference between these two types of tables.

SNMP Tables
Most of the MIB objects defined in this reference guide are organized into
SNMP tables. SNMP tables organize data into two-dimensional structural
arrays. In SNMP, objects that have a relationship to other objects are called
columnar objects. Columnar objects are objects used to form lists and tables.
When a MIB group is divided into one or more discrete tables, the word table
has a technical meaning. An example is the section of this reference guide
entitled Universal Unique Identifier (UUID). The UUID object has a type
and a value that uniquely identifies an object such as a chassis. The table
defines all of the variables that comprise the managed object UUID.
The following table is an example of an SNMP table. The table contains
variables that must occur in a definite sequence. In the example table the
defined variables are UUID Chassis Index, UUID Index, UUID Type, and
UUID Value.

Example SNMP Table

UUID Table
These objects comprise the Server Administrator definitions for the UUID.
Name uUIDTable
Object ID 1.3.6.1.4.1.674.10892.1.300.20
Description Defines the UUID table.
Syntax SEQUENCE OF UUIDTableEntry
Access Not accessible

28 Introduction
book.book Page 29 Monday, March 14, 2011 3:01 PM

UUID Table Entry

Name uUIDTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1
Description Defines the UUID table entry.
Syntax UUIDTableEntry
Access Not accessible
Index uUIDIndex, uUIDchassisIndex

UUID Chassis Index


Name uUIDchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

UUID Index

Name uUIDIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2
Description Defines the index of the UUID in a specified chassis.
Syntax DellObjectRange
Access Read-only

UUID Type

Name uUIDType
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3
Description Defines the type of the UUID for this chassis.
Syntax DellUUIDType
Access Read-only

Introduction 29
book.book Page 30 Monday, March 14, 2011 3:01 PM

UUID Value
Name uUIDValue
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4
Description Defines the value of the UUID for this chassis.
Syntax Octet String (SIZE[16])
Access Read-only

Reference Guide Content Tables


NOTE: Variable values are defined for any variable that is Server
Administrator-specific. Industry-standard variable definitions are documented
in "Standard Data Type Definitions" on page 761.
Some of the tables in this guide have no technical significance in SNMP.
These tables are designed to show information in a readable form. The
following table, for example, defines the Server Administrator-specific variable,
DellFanControlCapabilities. The table provides the name of the variable, its data
type, the values that are valid for the variable, and the meaning of each value.

Table 1-9. Example Variable Type Definition Table

Variable Name: DellFanControlCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The fan’s capabilities are unknown.
lowSpeedCapable(2) The fan can be set to low speed.
highSpeedCapable(4) The fan can be set to high speed.
lowOrhighSpeedCapable(6) The fan can be set to low or high speed.

This type of table is used throughout the reference guide to list and define
variable values. Tables that explain Server Administrator-specific variable
values are located in the final section of sections that define Server
Administrator-specific variables. In the preceding example, the variable name
is DellFanControlCapabilities. This variable must be expressed as an integer
and has four possible values: unknown, lowSpeedCapable,
highSpeedCapable, and lowOrhighSpeedCapable.

30 Introduction
book.book Page 31 Monday, March 14, 2011 3:01 PM

Section Organization
Sections in this reference guide are based on the Server Administrator MIBs,
so the complexity of each section depends on the complexity of each MIB
group. The first section provides a high-level introduction to the MIB group.
If the group is defined by one or more tables, the second section lists these
tables. The third section documents the variables that comprise the group,
and if applicable, the variables that comprise the tables. The fourth section
contains definitions for any Server Administrator-specific variables that are
used in the section. The following example shows the typical content of these
four sections:
1 BIOS Setup Control Group
This section explains the purpose of the MIB group and summarizes the
major features of the component groups.
2 BIOS Group Tables
If there is more than one SNMP table for a group, this section lists all of
the tables. For this BIOS group example, there are eight tables listed.
In each section, double-clicking any table on the list takes you to that table.
• BIOS Setup Control Table
• SCSI Control Table
• Parallel Port Control Table
• Serial Port Control Table
• USB Control Table
• IDE Control Table
• Diskette Control Table
• Network Interface Control Table
3 Variables that make up each table in the group
This section documents the variables for the eight tables that comprise the
BIOS group.

Introduction 31
book.book Page 32 Monday, March 14, 2011 3:01 PM

4 BIOS Variable Values


This section explains any Server Administrator-specific variables and data
types that are used in this section. In the BIOS group example, there are
17 unique, Server Administrator-specific variable meanings. Information on
each Server Administrator-specific variable is presented in a formatted table.

Other Documents You May Need


In addition to this guide, you can access the following guides available on the
Dell Support website at support.dell.com/manuals. On the Manuals page,
click SoftwareSystems Management. Click the appropriate product link
on the right-side to access the documents.
• The Server Administrator Messages Reference Guide lists the messages that
you can receive on your systems management console or on your operating
system’s event viewer. This guide explains the text, severity, and cause of
each message that the server administrator issues.
• The Server Administrator CIM Reference Guide documents the Common
Information Model (CIM) provider, an extension of the standard
management object format (MOF) file. The Server-Administrator CIM
provider documents supported classes of management objects.
• The Glossary provides information on the terms used in this document.

Introduction to the Server Administrator


SNMP Subagent
This guide provides formatted information drawn primarily from the MIB
files written for the Server Administrator services that support the SNMP
protocol.
For each of the variables defined in the MIBs, the following fields are specified:
• Variable name
• OID or unique identifying number
• Description
• Data type of the variable (for example: integer, string, octet string)
• Whether the variable is accessible, not accessible, read-only, or read-write
• Index or indexes, if applicable

32 Introduction
book.book Page 33 Monday, March 14, 2011 3:01 PM

For each MIB group that has unique variable definitions, tables are included
in the last section of the section to explain the meaning of the terms.
Standards for writing MIBs are defined by the Internet Engineering Task
Force (IETF). Structure of Management Information (SMI) is a standard that
specifies the rules for defining the structure and type of managed objects and
events in a MIB. SMIv1 is specified in Request For Comments (RFC) 1155.
The Server Administrator MIB conforms to the SMIv1 standard.
SNMP is a systems management standard originally designed for network
management. SNMP manages much more than networks. Information
Technology (IT) professionals use SNMP for monitoring and managing
computer systems and the various components and peripherals supported by
their systems.
SNMP standards are defined by the Internet Engineering Task Force (IETF).
SNMP version 1 was published in August 1988 and is the most commonly
supported version of SNMP. SNMP version 2 was first published in May 1993,
but has not gained widespread market acceptance. SNMP version 3 was
recently completed and has addressed security issues that exist in version 1.
All SNMP systems consist of one or more managed systems that provide data
through an SNMP agent to a management system. The management system
provides a user interface to view data from the managed systems. The
management system and managed systems communicate over a network
(typically through User Datagram Protocol/Internet Protocol [UDP/IP]).
The management system and a managed system communicate by means of a
common data schema. SNMP MIB files define the structure, type, and values
of the SNMP data. While MIBs can be standardized or enterprise specific,
most operating systems supply SNMP agents for the standard MIB-I and
MIB-II schemas. MIB-I defines a base set of standard management information
for systems implementing the Internet Protocol (IP) suite. MIB-II defines
characteristics of the system, characteristics of network interfaces, and
characteristics of components of the IP on the system. In addition to the
standard MIBs, many hardware vendors have defined MIBs that provide
management data specific to their systems and peripheral devices.
Monitored data can be retrieved through SNMP using the Get command.
Typically, this command requires the host name or IP address of the target
machine as well as the OID of the data to retrieve. Exact details are dependent
on the operating system and the development tools being used to create the
management application. The Get command has a variant known as GetNext.

Introduction 33
book.book Page 34 Monday, March 14, 2011 3:01 PM

SNMP Management Information Base Object Identifiers


Each data class within a Management Information Base (MIB) is defined by
an Object Identifier (OID). OIDs are unique across all MIBs. An OID
consists of a series of digits separated by periods. The OID functions in a
similar fashion to a phone number. The phone number 011-512-471-0000
uniquely identifies a single phone. The phone number can be broken down
into a number of components to uniquely identify a phone. The first
component, 011, is the country code for the United States. The second
component, 512, identifies the area code for central Texas. The third
component, 471, is the phone exchange for a large state university in the city
of Austin. The final component, 0000, is the main switchboard.
There are two main differences between the phone number example and an
actual OID. The first difference is that there are many more components in
an OID, up to 128. The combination of these components is called an OID
prefix. The second difference is that OIDs support the concept of indexes or
keys. The OID prefix specifies the data class but does not specify an instance of
the data within the class. Indexes can be used to identify the instances of a data
class. These indexes are referred to as the OID suffix.
The assignment of values for each OID prefix component can be illustrated
by using a tree structure. The following is an example of an OID assignment:

ROOT
CCITT(0)
ISO(1)
ORG(3)
DOD(6)
INTERNET(1)
MGMT(2)
MIB(1)
EXPERIMENTAL(3)
PRIVATE(4)
ENTERPRISES(1)
DELL(674)
SNMPv2(6)

34 Introduction
book.book Page 35 Monday, March 14, 2011 3:01 PM

In the preceding example, the OID prefix for the Dell enterprise would be
1.3.6.1.4.1.674.
The numbers in boldface type show the categories and numbers that apply to
Server Administrator. All Server Administrator-defined OIDs consist of
1.3.6.1.4.1.674 followed by additional component values.

SNMP Security
SNMP version 1 has a very limited security mechanism. SNMP agents
support the use of a community string, which is configured at each SNMP
agent and is passed as a part of all SNMP request messages. There is no
verification that the requester is actually a member of the
specified community. As most system and network management data is not
confidential, this limited security is acceptable for Get types of requests. On
the other hand, this security is not acceptable for Set types of operations
where an SNMP request could power off a system, reconfigure a redundant
array of independent disks (RAID) card, and so on. Some vendors have
chosen not to support SNMP Set operations for this reason. Server
Administrator is able to support SNMP Set operations because its SNMP
agents implement a hash/digest mechanism to prevent unauthorized SNMP
Set operations. One limitation of this practice is that only server
administrator-developed SNMP management applications have the capability
to support the hash/digest mechanism.
NOTE: The default SNMP agent configuration usually includes a SNMP community
name such as public. For security reasons, change the SNMP community names
from their default values. For information about changing SNMP community names,
see the Dell OpenManage Server Administrator User’s Guide available on the Dell
Support website at support.dell.com/manuals. For additional guidelines, see the
Securing an SNMP Environment article, dated May 2003, in the Dell Power
Solutions magazine. This magazine is also available at dell.com/powersolutions.
NOTE: Server Administrator provides support to enable or disable SNMP Set
operations. For more information on enabling or disabling SNMP Set operations in
Server Administrator, see the Dell OpenManage Server Administrator User’s Guide
or the Dell OpenManage Server Administrator Command Line Interface
User's Guide on the Dell Support website at support.dell.com/manuals.

Introduction 35
book.book Page 36 Monday, March 14, 2011 3:01 PM

Management Actions
Management actions can be performed using the SNMP Set command.
These actions can consist of configuring a phone number for the system’s
owner, rebooting a system, or changing the asset tag of the system. See the
previous section, "SNMP Security" on page 35, for limitations on Set
operations.

SNMP Traps
SNMP is frequently used to monitor systems for fault conditions such as
temperature violations, hard drive failures, and so on. Management
applications can monitor for these conditions by polling the appropriate
OIDs with the Get command and analyzing the returned data. This method
has its drawbacks. If it is done frequently, significant amounts of network
bandwidth can be consumed. If it is done infrequently, the response to the
fault condition may not occur in a timely fashion. SNMP traps avoid these
limitations of the polling method.
An SNMP trap is an asynchronous event indicating that something
significant has occurred. This is analogous to a pager receiving an important
message, except that the SNMP trap frequently contains all the information
needed to diagnose a fault.
Two drawbacks to SNMP traps are that they are sent using UDP, which is not
a guaranteed delivery mechanism, and that they are not acknowledged by
the receiver.
An SNMP trap message contains the trap’s enterprise OID, the agent
IP address, a generic trap ID, the specific trap ID, a time stamp, and zero or
more variable bindings (varbinds). The combination of an enterprise OID
and a specific trap ID uniquely identifies each Server Administrator-defined
trap. A varbind consists of an OID and its value and provides additional
information about the trap.
In order for a management system to receive SNMP traps from a managed
system, the node must be configured to send traps to the management
system. Trap destination configuration is dependent on the operating system.
When this configuration is done, a management application on the
management system can wait for traps and act on them when received.
For a list of traps supported by the server administrator SNMP subagent,
see "Traps" on page 709.

36 Introduction
book.book Page 39 Monday, March 14, 2011 3:01 PM

2
Updates For Dell OpenManage
Server Administrator Version 6.5
This section contains information added or updated for the current release.
NOTE: OpenManage Storage Management updates for Version 6.5 are also listed
in this section.

What’s New in This Release


New Features Added
• Added an attribute (Network Device Capability) to the Network Device
Table in the Device Group.
• Added enumeration values for the Network Device Capability attribute in
the Device Group Variable Values section.
• Added attributes to the Physical Memory Configuration Table in the
Memory Group.
• Added enumeration values for the Physical Memory Configuration
Redundant Capabilities and Physical Memory Configuration Redundant
Settings attributes in the Memory Group Variable Values section.
• Added an attribute to the Enclosure Table section of the Storage
Management Group.
• Updated the Syntax row of specific MIB tables in the Controller and Array
Disk Tables sections of the Storage Management Group.
For a list of Platforms, Operating Systems, Browsers support added and
deprecated, refer to the Dell OpenManage Server Administrator Version 6.5
User's Guide and Dell Systems Software Support Matrix Version 6.5 at
support.dell.com/manuals.

Updates for Dell OpenManage Server Administrator Version 6.5


book.book Page 40 Monday, March 14, 2011 3:01 PM

Device Group
Device Tables
The following MIB table in the Device Group is updated for the current
release:
• Network Device Table
For information about the other Device Group MIB tables, see "Device
Group" on page 267.

Network Device Table


This section provides information about the updates done to the Network
Device Table for the current release. For all other information about the
Network Device Table, see "Network Device Table" on page 309.

Network Device Capabilities

Name networkDeviceCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.29
Description Defines the capabilities of a network device. If this value is
notSupported(0), the networkDeviceTOECapabilityFlags,
networkDeviceTOEEnabled,
networkDeviceRDMACapabilityFlags,
networkDeviceRDMAEnabled,
networkDeviceiSCSICapabilityFlags and
networkDeviceiSCSIEnabled attributes should be used to
determine the network device capabilities.
If the supported(1) bit is on, this attribute should be used to
determine the network device capabilities, and the attributes
mentioned above should not be used.
NOTE: For a network device on Converged Network Adapter (CNA),
this attribute provides capability information for the CNA and
not for the network device.
Syntax DellNetworkDeviceCapabilities
Access Read-only

40 Updates For Dell OpenManage Server Administrator Version 6.5


book.book Page 41 Monday, March 14, 2011 3:01 PM

Device Group Variable Values


The following attribute has enumeration values added for this release:

Table 2-1. Network Device Capabilities

Variable Name: DellNetworkDeviceCapabilities


Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values Meaning of Data Value
notSupported(0) Device does not support reporting capabilities.
supported(1) Device supports reporting capabilities.
toe(2) Device has TOE capability.
iscsiOffload(4) Device has iSCSI Offload capability.
fcoeOffload(8) Device has FCoE Offload capability.

For information about the other Device Group Variable Values tables, see
"Device Group Variable Values" on page 326.

Memory Group
Physical Memory Tables
The following MIB table in the Memory Group is updated for the current
release:
• Physical Memory Configuration Table
For information about the other Memory Group MIB tables, see "Memory
Group" on page 369.

Physical Memory Configuration Table


This section provides information about the updates done to the Physical
Memory Configuration Table for the current release. For all other information
about the Physical Memory Configuration Table, see "Physical Memory
Configuration Table" on page 377.

Updates For Dell OpenManage Server Administrator Version 6.5 41


book.book Page 42 Monday, March 14, 2011 3:01 PM

Physical Memory Configuration Memory Operating Mode Capabilities

Name physicalMemoryConfigMOMCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.8
Description Defines the Memory Operating Mode capabilities of the
physical memory.
Syntax DellPhysicalMemoryConfigMOMCapabilities
Access Read-only

Physical Memory Configuration Memory Operating Mode Settings

Name physicalMemoryConfigMOMSettings
Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.9
Description Defines the Memory Operating Mode settings of the physical
memory.
Syntax DellPhysicalMemoryConfigMOMSettings
Access Read-only

Memory Group Variable Values


The following attributes have enumeration values added for this release:
• Physical Memory Configuration Memory Operating Mode Capabilities
• Physical Memory Configuration Memory Operating Mode Settings
• Physical Memory Configuration Redundant Capabilities
• Physical Memory Configuration Redundant Settings
For information about the other Memory Group Variable Values tables, see
"Memory Group Variable Values" on page 387.

42 Updates For Dell OpenManage Server Administrator Version 6.5


book.book Page 43 Monday, March 14, 2011 3:01 PM

Table 2-2. Physical Memory Configuration Memory Operating Mode Capabilities

Variable Name: DellPhysicalMemoryConfigMOMCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) There are no memory operating mode
capabilities.
unknownCapabilities(1) Memory operating mode capabilities are
unknown.
momOptimizerCapable(2) Optimizer memory operating feature is
supported.
momSpareCapable(4) Spare memory operating feature is supported.
momMirrorCapable(8) Mirror memory operating feature is
supported.
momAdvancedECCCapable(16) Advanced ECC memory operating feature is
supported.

Table 2-3. Physical Memory Configuration Memory Operating Mode Settings

Variable Name: DellPhysicalMemoryConfigMOMSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) There are no memory operating mode
settings.
unknown(1) Memory operating mode settings are
unknown.
The following redundant settings are mutually exclusive:
momOptimizerEnabled(2) Optimizer memory operating feature is
enabled.
momSpareEnabled(4) Spare memory operating feature is enabled.
momMirrorEnabled(8) Mirror memory operating feature is enabled.
momAdvancedECCEnabled(16) Advanced ECC memory operating feature is
enabled.

Updates For Dell OpenManage Server Administrator Version 6.5 43


book.book Page 44 Monday, March 14, 2011 3:01 PM

Table 2-4. Physical Memory Configuration Redundant Capabilities

Variable Name:
DellPhysicalMemoryConfigRedundantCapabilities
Data Type: Integer
Possible Data Values Meaning of Data Value
dddcCapable(16) DDDC redundancy is supported.

Table 2-5. Physical Memory Configuration Redundant Settings

Variable Name: DellPhysicalMemoryConfigRedundantSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
dddcEnabled(16) DDDC redundancy is enabled.

Storage Management Group


Physical Devices Group
The following MIB tables in the Physical Devices Group are updated for the
current release:
• Controller Table—describes available properties for each controller on the
managed system.
• Enclosure Table—describes available properties for each enclosure on the
managed system.
• Array Disk Table—describes available properties for each physical array
disk on the managed system.

Controller Table
This section provides information about the updates done to the Controller
Table in the current release. For all other information about the Controller
Table, see "Controller Table" on page 563.

44 Updates For Dell OpenManage Server Administrator Version 6.5


book.book Page 45 Monday, March 14, 2011 3:01 PM

Controller Storport Driver Version

Name controllerStorportDriverVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.55
Description Provides current Windows OS storport driver version. Not
applicable for Linux.
Syntax DisplayString
Access Read-only

Controller Minimum Required Storport Version

Name controllerMinimumRequiredStorportVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.56
Description Provides minimum required storport driver version for Windows
OS only.
Syntax DisplayString
Access Read-only

Enclosure Table
This section provides information about the updates done to the Enclosure
Table in the current release. For all other information about the Enclosure
Table, see "Enclosure Table" on page 588.

Enclosure Express Service Code

Name enclosureExpressServiceCode
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.34
Description Is base10 converted numerical value of service tag.
Syntax DisplayString
Access Read-only

Updates For Dell OpenManage Server Administrator Version 6.5 45


book.book Page 46 Monday, March 14, 2011 3:01 PM

Array Disk Table


This section provides information about the updates done to the Array Disk
Table in the current release. For all other information about the Array Disk
Table, see "Array Disk Table" on page 599 section.

Array Disk Alta Vendor Id

Name arrayDiskAltaVendorId
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.37
Description Provides vendor information for Alta interposer.
Syntax DisplayString
Access Read-only

Array Disk Alta Product Id

Name arrayDiskAltaProductId
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.38
Description Provides product ID for Alta interposer.
Syntax DisplayString
Access Read-only

Array Disk Alta Revision Id

Name arrayDiskAltaRevisionId
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.39
Description Provides revision ID for Alta interposer.
Syntax DisplayString
Access Read-only

46 Updates For Dell OpenManage Server Administrator Version 6.5


book.book Page 47 Monday, March 14, 2011 3:01 PM

3
Instrumentation MIB Version Group
The Instrumentation Management Information Base (MIB) Version Group
defines the attributes that identify the version of the Instrumentation MIB
supported by the systems management software.
The mIBMajorVersionNumber, mIBMinorVersionNumber, and
mIBMaintenanceVersionNumber attributes are scalar objects, meaning that
they are not related to other MIB objects and are thus not placed in a table.

Management Information Base Major Version


Number
Name mIBMajorVersionNumber
Object ID 1.3.6.1.4.1.674.10892.1.1.1.0
Description Defines the major version number of the version of this MIB
supported by the systems management software. For example,
if the MIB version is 1.2.3, the major version number is 1.
A major version number change indicates a major change in
object functionality.
Syntax DellUnsigned8BitRange
Access Read-only

Instrumentation MIB Version Group 47


book.book Page 48 Monday, March 14, 2011 3:01 PM

Management Information Base Minor Version


Number
Name mIBMinorVersionNumber
Object ID 1.3.6.1.4.1.674.10892.1.1.2.0
Description Defines the minor version number of the version of this MIB
supported by the systems management software. For example,
if the MIB version is 1.2.3, the minor version number is 2.
A minor revision provides additional support for new objects as
well as problem fixes.
Syntax DellUnsigned8BitRange
Access Read-only

Management Information Base Maintenance


Version Number
Name mIBMaintenanceVersionNumber
Object ID 1.3.6.1.4.1.674.10892.1.1.3.0
Description Defines the maintenance version number for the version of this
MIB supported by the systems management software.
For example, if the MIB version is 1.2.3, the maintenance
version number is 3.
Syntax DellUnsigned8BitRange
Access Read-only

48 Instrumentation MIB Version Group


book.book Page 49 Monday, March 14, 2011 3:01 PM

4
Systems Management Software
Group
The Systems Management Software Group allows users to see information
about the standards and software that are supported by the agent of a
particular managed computer chassis. The Systems Management Software
Group classifies each computer chassis according to the systems management
standard that the agent supports.
Additional objects define the universal resource locator (URL) of the systems
management software and the language in which systems management
information displays. Defining these objects enables users to manage a
system using an internet browser. You can access Server Administrator using
the secure hypertext transfer protocol (https) and a pre-assigned port number
of 1311, or you can specify a port number of your own choosing.
NOTE: Using the Software Server Preferences menu of Server Administrator,
you can bind to either one IP address or to all IP addresses.
To manage a system locally using Server Administrator, type the following in
the address field of your browser: https://localhost:<1311 or user-specified
port number>
To manage a system remotely using Server Administrator, type one of the
following in the address field of your browser:
https://<systemname>:<1311 or user specified port number> or https://<IP
address>:<1311 or user specified port number>

Systems Management Software


The following objects describe the fields for server administrator systems
management information. The systems management software variables are
scalar objects, meaning that they are not related to other management
information base (MIB) objects and are thus not placed in a table.

Systems Management Software Group 49


book.book Page 50 Monday, March 14, 2011 3:01 PM

Systems Management Software Name

Name systemManagementSoftwareName
Object ID 1.3.6.1.4.1.674.10892.1.100.1
Description Defines the systems management software product name.
Syntax DellString
Access Read-only

Systems Management Software Version Number Name

Name systemManagementSoftwareVersionNumberName
Object ID 1.3.6.1.4.1.674.10892.1.100.2
Description Defines the version number of the systems management
software.
Syntax DellString
Access Read-only

Systems Management Software Build Number

Name systemManagementSoftwareBuildNumber
Object ID 1.3.6.1.4.1.674.10892.1.100.3
Description Defines the build number of the systems management software.
Syntax DellUnsigned16BitRange
Access Read-only

Systems Management Software Description Name

Name systemManagementSoftwareDescriptionName
Object ID 1.3.6.1.4.1.674.10892.1.100.4
Description Defines the description of the systems management software.
Syntax DellString
Access Read-only

50 Systems Management Software Group


book.book Page 51 Monday, March 14, 2011 3:01 PM

Systems Management Software Supported Protocol

Name systemManagementSoftwareSupportedProtocol
Object ID 1.3.6.1.4.1.674.10892.1.100.5
Description Defines the systems management standards (SNMP or CIM)
supported by the systems management software.
Syntax SMSSupportedTypes (See Table 4-1)
Access Read-only

Systems Management Software Preferred Protocol

Name systemManagementSoftwarePreferredProtocol
Object ID 1.3.6.1.4.1.674.10892.1.100.6
Description Defines the preferred systems management standard for the
systems management software.
Syntax SMSSupportedTypes (See Table 4-1)
Access Read-only

Systems Management Software Update Level Name

Name systemManagementSoftwareUpdateLevelName
Object ID 1.3.6.1.4.1.674.10892.1.100.7
Description Defines the update level of the system management software.
Syntax DellString
Access Read-only

Systems Management Software URL Name

Name systemManagementSoftwareURLName
Object ID 1.3.6.1.4.1.674.10892.1.100.8
Description Defines the universal resource locator (URL) of the systems
management software.
Syntax DisplayString (SIZE (0..1024))

Systems Management Software Group 51


book.book Page 52 Monday, March 14, 2011 3:01 PM

Name systemManagementSoftwareURLName
Access Read-only

Systems Management Software Language Name

Name systemManagementSoftwareLanguageName
Object ID 1.3.6.1.4.1.674.10892.1.100.9
Description Defines the language of the systems management software.
Syntax DisplayString (SIZE (0..255))
Access Read-only

Systems Management Software Global Version Name

Name systemManagementSoftwareGlobalVersionName
Object ID 1.3.6.1.4.1.674.10892.1.100.10
Description Defines the global version of the systems management software.
Syntax DellString
Access Read-only

Systems Management Software Feature Flags

Name systemManagementSoftwareFeatureFlags
Object ID 1.3.6.1.4.1.674.10892.1.100.11
Description Defines the features of the systems management software.
Syntax SMSFeatureFlags (See Table 4-2)
Access Read-only

Systems Management Software SNMP Agent Feature Flags

Name systemManagementSoftwareSNMPAgentFeatureFlags
Object ID 1.3.6.1.4.1.674.10892.1.100.12
Description Defines the features of the SNMP agent software provided by the
operating system.

52 Systems Management Software Group


book.book Page 53 Monday, March 14, 2011 3:01 PM

Name systemManagementSoftwareSNMPAgentFeatureFlags
Syntax SMSSNMPAgentFeatureFlags (See Table 4-3)
Access Read-only

Systems Management Software Manufacturer Name

Name systemManagementSoftwareManufacturerName
Object ID 1.3.6.1.4.1.674.10892.1.100.13
Description Defines the manufacturer of the systems management software.
Syntax DellString
Access Read-only

Systems Management Software Variable Values


This section includes definitions of server administrator-specific variable
values used in this section.

Table 4-1. Systems Management Software Supported Standards

Variable Name: SMSSupportedTypes


Data Type: Integer
Possible Data Values Meaning of Data Value
supportsSNMP(1) This system supports SNMP.
supportsDMI(2) This system supports DMI.
supportsSNMPandDMI(3) This system supports SNMP and DMI.
supportsCIMOM(4) This system supports CIM.
supportsSNMPandCIMOM(5) This system supports SNMP and CIM.

Systems Management Software Group 53


book.book Page 54 Monday, March 14, 2011 3:01 PM

Table 4-2. Systems Management Software Feature Flags

Variable Name: SMSFeatureFlags


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The Systems Management Software
features are not enabled.
webOneToOneManagementPreferred(1) The web 1:1 management preferred
feature is enabled.

Table 4-3. Systems Management Software SNMP Agent Feature Flags

Variable Name: SMSSNMPAgentFeatureFlags


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The Systems Management Software
SNMP agent features are not enabled.
supportsSparseTables(1) The SNMP agent supports sparse tables.

54 Systems Management Software Group


book.book Page 55 Monday, March 14, 2011 3:01 PM

5
System State Group
The Management Information Base (MIB) variables presented in this section
enable you to track various attributes that describe the state of the critical
components supported by your system. Components monitored under the
System State Group include power supplies, AC power cords, AC power
switches, and cooling devices, as well as temperature, fan, amperage,
and voltage probes.

System State Group Table


The System State Group defines objects in the System State MIB table.

System State Table


The systemStateGlobalSystemStatus variable provides overall system health
status and includes rolled-up (that is, worst) status for Instrumentation and
Storage. This variable monitors the overall system health status. It reflects
changes to systemStateChassisStatus variable, which represents
Instrumentation health status and agentGlobalSystemStatus (dcstorag.mib),
which represents Storage health status.
The systemStateChassisStatus variable provides the rolled-up health status
for the subsystems associated with the chassis that is represented by the row
in the systemStateTable. Changes to the variables in "List 1" on page 56, each
of which indicates the rolled-up health status of all the components of the
corresponding subsystem, are reflected in systemStateChassisStatus variable.
For example, systemStatePowerSupplyStatusCombined provides the rolled-
up status of all power supplies for the chassis.
The variables in "List 2" on page 56 provide the health status of each
component of the corresponding subsystem. Each octet of the value
represents a component. If a power supply fails, the corresponding entry in
systemStatePowerSupplyStatusDetails,
systemStatePowerSupplyStatusCombined, systemStateChassisStatus, and
systemStateGlobalSystemStatus transitions to critical.

System State Group 55


book.book Page 56 Monday, March 14, 2011 3:01 PM

List 1
Variables that provide rolled-up health status for all components in associated
subsystem in chassis:
• systemStatePowerSupplyStatusCombined
• systemStateVoltageStatusCombined
• systemStateAmperageStatusCombined
• systemStateCoolingDeviceStatusCombined
• systemStateTemperatureStatusCombined
• systemStateMemoryDeviceStatusCombined
• systemStateChassisIntrusionStatusCombined
• systemStateACPowerCordStatusCombined
• systemStateEventLogStatus
• systemStatePowerUnitStatusCombined
• systemStateCoolingUnitStatusCombined
• systemStateACPowerSwitchStatusCombined
• systemStateRedundantMemoryUnitStatusCombined
• systemStateProcessorDeviceStatusCombined
• systemStateBatteryStatusCombined
• systemStateSDCardUnitStatusCombined
• systemStateSDCardDeviceStatusCombined

List 2
Variables that provide health status of each component in associated
subsystem in chassis:
• systemStatePowerSupplyStatusDetails
• systemStateVoltageStatusDetails
• systemStateAmperageStatusDetails
• systemStateCoolingDeviceStatusDetails
• systemStateTemperatureStatusDetails
• systemStateMemoryDeviceStatusDetails

56 System State Group


book.book Page 57 Monday, March 14, 2011 3:01 PM

• systemStateChassisIntrusionStatusDetails
• systemStateACPowerCordStatusDetails
• systemStatePowerUnitStatusList
• systemStateCoolingUnitStatusList
• systemStateACPowerSwitchStatusList
• systemStateRedundantMemoryUnitStatusList
• systemStateProcessorDeviceStatusList
• systemStateBatteryStatusList
• systemStateSDCardUnitStatusList
• systemStateSDCardDeviceStatusList

System State Table


The following object sets up the System State Table:

Name systemStateTable
Object ID 1.3.6.1.4.1.674.10892.1.200.10
Description Defines the System State Table.
Syntax SEQUENCE OF SystemStateTableEntry
Access Not accessible

System State Table Entry

Name systemStateTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1
Description Defines the System State Table entry.
Syntax SystemStateTableEntry
Access Not accessible
Index systemStatechassisIndex

System State Group 57


book.book Page 58 Monday, March 14, 2011 3:01 PM

System State Chassis Index

Name systemStatechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

System State Global System Status

Name systemStateGlobalSystemStatus
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.2
Description Defines the global system status of all chassis being monitored by
this instrumentation instance.
Syntax DellStatus
Access Read-only

System State Chassis State

Name systemStateChassisState
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.3
Description Defines the system state of this chassis.
Syntax DellStateSettings
Access Read-only

System State Chassis Status

Name systemStateChassisStatus

Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.4

Description Defines the system status of this chassis.

Syntax DellStatus

Access Read-only

58 System State Group


book.book Page 59 Monday, March 14, 2011 3:01 PM

System State Power Unit State Details

Name systemStatePowerUnitStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.5
Description Defines the state of all power units in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the state of a specific power unit. The first byte returned
represents the state of the first power unit, the second byte returned
represents the state of the second power unit, and so on. The bytes
have the same definition type as DellStateSettings.
Syntax Octet String (Size (1..128))
Access Read-only

System State Power Unit Status Redundancy

Name systemStatePowerUnitStatusRedundancy
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.6
Description Defines the system status of the power unit(s) in this chassis.
Syntax DellStatus
Access Read-only

System State Power Unit Status Details

Name systemStatePowerUnitStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.7
Description Defines the status of all power units in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the status of a specific power unit. The first byte returned
represents the status of the first power unit, the second byte
returned represents the status of the second power unit, and so on.
The bytes have the same definition type as DellStatusRedundancy.
Syntax Octet String (Size (1..128))
Access Read-only

System State Group 59


book.book Page 60 Monday, March 14, 2011 3:01 PM

System State Power Supply State Details

Name systemStatePowerSupplyStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.8
Description Defines the state of all power supplies in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the state of a specific power supply. The first byte returned
represents the state of the first power supply, the second byte
returned represents the state of the second power supply, and so on.
The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size (1..128))
Access Read-only

System State Power Supply Status Combined

Name systemStatePowerSupplyStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.9
Description Defines the status of all power supplies in this chassis.
Syntax DellStatus
Access Read-only

System State Power Supply Status Details

Name systemStatePowerSupplyStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.10
Description Defines the status of all power supplies in this chassis. The results
are returned as a binary octet string, Each byte of the octet string
represents the status of a specific power supply. The first byte
returned represents the status of the first power supply, the second
byte returned represents the status of the second power supply,
and so on. The bytes have the same definition type as DellStatus.
Syntax Octet String (Size (1..128))
Access Read-only

60 System State Group


book.book Page 61 Monday, March 14, 2011 3:01 PM

System State Voltage State Details

Name systemStateVoltageStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.11
Description Defines the state of all voltage probes in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the status of a specific voltage probe. The first byte returned
represents the status of the first voltage probe, the second byte
returned represents the status of the second voltage probe, and so
on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size (1..128))
Access Read-only

System State Voltage Status Combined

Name systemStateVoltageStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.12
Description Defines the status of all voltage probes in this chassis.
Syntax DellStatus
Access Read-only

System State Voltage Status Details

Name systemStateVoltageStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.13
Description Defines the status of all voltage probes in this chassis.
Syntax Octet String (Size (1..128))
Access Read-only

System State Group 61


book.book Page 62 Monday, March 14, 2011 3:01 PM

System State Amperage State Details

Name systemStateAmperageStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.14
Description Defines the state of all current probes in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the status of a specific current probe. The first byte
returned represents the state of the first current probe, the second
byte returned represents the state of the second current probe, and
so on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size (1..128))
Access Read-only

System State Amperage Status Combined

Name systemStateAmperageStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.15
Description Defines the status of all amperage probes in this chassis. The result
is returned as a combined status value. The value has the same
definition type as DellStatus.
Syntax DellStatus
Access Read-only

System State Amperage Status Details

Name systemStateAmperageStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.16
Description Defines the status of all amperage probes in this chassis. The results
are returned as a binary octet string. Each byte of the octet string
represents the status of a specific amperage probe. The first byte
returned represents the status of the first amperage probe, the
second byte returned represents the status of the second amperage
probe, and so on. The bytes have the same definition type as
DellStatus.
Syntax Octet String (Size (1..128))
Access Read-only

62 System State Group


book.book Page 63 Monday, March 14, 2011 3:01 PM

System State Cooling Unit State Details

Name statesystemStateCoolingUnitStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.17
Description Defines the state of all cooling units in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the state of a specific cooling unit. The first byte returned
represents the state of the first cooling unit, the second byte
returned represents the state of the second cooling unit, and so on.
The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size (1..128))
Access Read-only

System State Cooling Unit Status Redundancy

Name systemStateCoolingUnitStatusRedundancy
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.18
Description Defines the state of all cooling units in this chassis.
Syntax DellStatusRedundancy
Access Read-only

System State Cooling Unit State Details

Name systemStateCoolingUnitstateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.19
Description Defines the state of all cooling units in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the state of a specific cooling unit. The first byte returned
represents the state of the first cooling unit, the second byte
returned represents the state of the second cooling unit, and so on.
The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size (1..128))
Access Read-only

System State Group 63


book.book Page 64 Monday, March 14, 2011 3:01 PM

System State Cooling Device State Details

Name systemStateCoolingDeviceStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.20
Description Defines the state of all cooling devices in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the state of a specific cooling device. The first byte returned
represents the state of the first cooling device, the second byte
returned represents the state of the second cooling device, and so
on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size (1..128))
Access Read-only

System State Cooling Device Status Combined

Name systemStateCoolingDeviceStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.21
Description This attribute defines the cooling device status of all cooling devices
in this chassis. The results is returned as a combined status value.
The value has the same definition type as DellStatus.
Syntax DellStatus
Access Read-only

System State Cooling Device Status Details

Name systemStateCoolingDeviceStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.22
Description Defines the status of all cooling devices in this chassis. The results
are returned as a binary octet string. Each byte of the octet string
represents the status of a specific cooling device. The first byte
returned represents the status of the first cooling device, the second
byte returned represents the status of the second cooling device,
and so on. The bytes have the same definition type as DellStatus.
Syntax Octet String (Size (1..128))
Access Read-only

64 System State Group


book.book Page 65 Monday, March 14, 2011 3:01 PM

System State Temperature State Details

Name systemStateTemperatureStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.23
Description Defines the state of all temperature probes in this chassis.
The results are returned as a binary octet string. Each byte of the
octet string represents the state of a specific temperature probe.
The first byte returned represents the state of the first temperature
probe, the second byte returned represents the status of the second
temperature probe, and so on. The bytes have the same definition
type as DellStateSettings.
Syntax Octet String (Size(1..128))
Access Read-only

System State Temperature Status Combined

Name systemStateTemperatureStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.24
Description Defines the status of all temperature probes in this chassis.
The result is returned as a combined status value. The value has the
same definition type as DellStatus.
Syntax DellStatus
Access Read-only

System State Temperature Status Details

Name systemStateTemperatureStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.25
Description Defines the status of all temperature probes in this chassis. The first
byte returned represents the status of the first temperature probe,
the second byte returned represents the status of the second
temperature probe, and so on.
Syntax Octet String (Size(1..128)
Access Read-only

System State Group 65


book.book Page 66 Monday, March 14, 2011 3:01 PM

System State Memory Device State Details

Name systemStateMemoryDeviceStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.26
Description Defines the state of all memory devices in this chassis. The results
are returned as a binary octet string. Each byte of the octet string
represents the state of the specific memory device. The first byte
returned represents the state of the first memory device, the second
byte returned represents the status of the second memory device,
and so on. The bytes have the same definition type as
DellStateSettings.
Syntax Octet String (Size(1..128)
Access Read-only

System State Memory Device Status Combined

Name systemStateMemoryDeviceStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.27
Description Defines the status of all memory devices in this chassis.
Syntax DellStatus
Access Read-only

System State Memory Device Status Details

Name systemStateMemoryDeviceStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.28
Description Defines the status of all memory devices in this chassis. The results
are returned as a binary octet string. Each byte of the octet string
represents the status of a specific memory device. The first byte
returned represents the status of the first memory device, the
second byte returned represents the status of the second memory
device, and so on. The bytes have the same definition type as
DellStatus.
Syntax Octet String (Size(1..128)
Access Read-only

66 System State Group


book.book Page 67 Monday, March 14, 2011 3:01 PM

System State Chassis Intrusion State Details

Name systemStateChassisIntrusionStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.29
Description Defines the intrusion state of all intrusion detection devices in this
chassis. The results are returned as a binary octet string. Each byte of
the octet string represents the status of a specific intrusion detection
device. The first byte returned represents the status of the first
intrusion detection device, the second byte returned represents the
status of the second intrusion detection device, and so on. The bytes
have the same definition type as DellStateSettings.
Syntax Octet String (Size(1..128)
Access Read-only

System State Chassis Intrusion Status Combined

Name systemStateChassisIntrusionStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.30
Description Defines the intrusion status of all intrusion detection devices in this
chassis. The result is returned as a combined status value. The value
has the same definition type as DellStatus.
Syntax DellStatus
Access Read-only

System State Chassis Intrusion Status Details

Name systemStateChassisIntrusionStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.31
Description Defines the intrusion status of all intrusion detection devices in this
chassis. The first byte returned represents the status of the first
intrusion detection device, the second byte returned represents the
status of the second intrusion detection device, and so on.
Syntax Octet String (Size(1..128))
Access Read-only

System State Group 67


book.book Page 68 Monday, March 14, 2011 3:01 PM

System State AC Power Switch State Details

Name systemStateACPowerSwitchStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.32
Description Defines the individual state of all AC power switches in this chassis.
The first byte returned represents the state of the first AC power
switch, the second byte returned represents the state of the second
AC power switch, and so on.
Syntax Octet String (Size(1..128))
Access Read-only

System State AC Power Switch Status Redundancy

Name systemStateACPowerSwitchStatusRedundancy
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.33
Description Defines the overall redundancy status of the AC power switches in
this chassis.
Syntax DellStatusRedundancy
Access Read-only

System State AC Power Switch Status Details

Name systemStateACPowerSwitchStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.34
Description Defines the individual status of all AC power switches in this
chassis. The first byte returned represents the status of the first
AC power switch, the second byte returned represents the status of
the second AC power switch, and so on.
Syntax Octet String (Size(1..128))
Access Read-only

68 System State Group


book.book Page 69 Monday, March 14, 2011 3:01 PM

System State AC Power Cord State Details

Name systemStateACPowerCordStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.35
Description Defines the individual state of all AC power cords for any AC power
switches in this chassis. The first byte returned represents the state
of the first AC power cord, the second byte returned represents the
state of the second AC power cord, and so on.
Syntax Octet String (Size(1..128))
Access Read-only

System State AC Power Cord Status Combined

Name systemStateACPowerCordStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.36
Description Defines the overall status of all AC power cords for any AC power
switches in this chassis.
Syntax DellStatus
Access Read-only

System State AC Power Cord Status Details

Name systemStateACPowerCordStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.37
Description Defines the individual status of all AC power cords for any
AC power switches in this chassis. The first byte returned represents
the status of the first AC power cord, the second byte returned
represents the status of the second AC power cord, and so on.
Syntax Octet String (SIZE(1..128))
Access Read-only

System State Group 69


book.book Page 70 Monday, March 14, 2011 3:01 PM

System State Redundant Memory Unit State Details

Name systemStateRedundantMemoryUnitStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.38
Description Defines the state of all redundant memory units in this chassis.
The results are returned as a binary octet string, each byte of the
octet string represents the state of the specific object. The first byte
returned represents the state of the first object, and so on. The bytes
have the same definition type as DellStateSettings.
Syntax Octet String (Size(1..128))
Access Read-only

System State Redundant Memory Unit Status Redundancy

Name systemStateRedundantMemoryUnitStatusRedundancy
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.39
Description Defines the overall redundancy status for redundant memory.
Syntax DellStatusRedundancy
Access Read-only

System State Redundant Memory Unit Status Details

Name systemStateRedundantMemoryUnitStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.40
Description Defines the status of all redundant memory units in this chassis.
The results are returned as a binary octet string, each byte of the
octet string represents the status of the specific object. The first
byte returned represents the status of the first object, and so on.
The bytes have the same definition type as DellStatusRedundancy.
Syntax Octet String (Size(1..128))
Access Read-only

70 System State Group


book.book Page 71 Monday, March 14, 2011 3:01 PM

System State Event Log Status

Name systemStateEventLogStatus
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.41
Description Defines the overall status of this chassis (ESM) event log.
Syntax DellStatus
Access Read-only

System State Power Unit Status Combined

Name systemStatePowerUnitStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.42
Description Defines the combined status of all power units of this chassis.
Syntax DellStatus
Access Read-only

System State Power Unit Status List

Name systemStatePowerUnitStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.43
Description Lists the status of each power unit of this chassis. The results are
returned as a binary octet string where each byte of the octet string
represents the status of a power unit. The first byte returned
represents the status of the first power unit, and so on. The bytes
have the same definition type as DellStatus.
Syntax Octet String (Size(1..128))
Access Read-only

System State Group 71


book.book Page 72 Monday, March 14, 2011 3:01 PM

System State Cooling Unit Status Combined

Name systemStateCoolingUnitStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.44
Description Defines the combined status of all cooling units of this chassis.
Syntax DellStatus
Access Read-only

System State Cooling Unit Status List

Name systemStateCoolingUnitStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.45
Description Lists the status of each cooling unit of this chassis. The results are
returned as a binary octet string where each byte of the octet string
represents the status of a cooling unit. The first byte returned
represents the status of the first cooling unit, and so on. The bytes
have the same definition type as DellStatus.
Syntax Octet String (Size(1..128))
Access Read-only

System State AC Power Switch Status Combined

Name systemStateACPowerSwitchStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.46
Description Defines the combined status of all AC power switches of this
chassis.
Syntax DellStatus
Access Read-only

72 System State Group


book.book Page 73 Monday, March 14, 2011 3:01 PM

System State AC Power Switch Status List

Name systemStateACPowerSwitchStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.47
Description Lists the status of each AC power switch of this chassis. The results
are returned as a binary octet string where each byte of the octet
string represents the status of an AC power switch. The first byte
returned represents the status of the first AC power switch, and so
on. The bytes have the same definition type as DellStatus.
Syntax Octet String (Size(1..128))
Access Read-only

System State Redundant Memory Unit Status Combined

Name systemStateRedundantMemoryUnitStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.48
Description Defines the combined status of all redundant memory units of this
chassis.
Syntax DellStatus
Access Read-only

System State Redundant Memory Unit Status List

Name systemStateRedundantMemoryUnitStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.49
Description Lists the status of each redundant memory unit of this chassis.
The results are returned as a binary octet string where each byte of
the octet string represents the status of a redundant memory unit.
The first byte returned represents the status of the first redundant
memory unit, and so on. The bytes have the same definition type as
DellStatus.
Syntax Octet String (Size(1..128))
Access Read-only

System State Group 73


book.book Page 74 Monday, March 14, 2011 3:01 PM

System State Processor Device Status Combined

Name systemStateProcessorDeviceStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.50
Description Defines the combined status of all processor devices of this chassis.
Syntax DellStatus
Access Read-only

System State Processor Device Status List

Name systemStateProcessorDeviceStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.51
Description Lists the status of each processor device of this chassis. The results
are returned as a binary octet string where each byte of the octet
string represents the status of a processor device. The first byte
returned represents the status of the first processor device, and so
on. The bytes have the same definition type as DellStatus.
Syntax Octet String (Size(1..128))
Access Read-only

System State Battery Status Combined

Name systemStateBatteryStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.52
Description Defines the combined status of all batteries of this chassis.
Syntax DellStatus
Access Read-only

System State Battery Status List

Name systemStateBatteryStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.53

74 System State Group


book.book Page 75 Monday, March 14, 2011 3:01 PM

Name systemStateBatteryStatusList
Description Lists the status of each battery of this chassis. The results are
returned as a binary octet string where each byte of the octet string
represents the status of a battery. The first byte returned represents
the status of the first battery, and so on. The bytes have the same
definition type as DellStatus.
Syntax Octet String (Size(1..128))
Access Read-only

System State SD Card Unit Status Combined

Name systemStateSDCardUnitStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.54
Description Defines the combined status of all SD Card units of this chassis.
Syntax DellStatus
Access Read-only

System State SD Card Unit Status List

Name systemStateSDCardUnitStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.55
Description Lists the status of each SD Card unit of this chassis. The results are
returned as a binary octet string where each byte of the octet string
represents the status of a SD Card unit. The first byte returned
represents the status of the first SD Card unit, and so on. The bytes
have the same definition type as DellStatus.
Syntax Octet String (Size(1..128))
Access Read-only

System State SD Card Device Status Combined

Name systemStateSDCardDeviceStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.56
Description Defines the combined status of all SD Card devices of this chassis.

System State Group 75


book.book Page 76 Monday, March 14, 2011 3:01 PM

Name systemStateSDCardDeviceStatusCombined
Syntax DellStatus
Access Read-only

System State SD Card Device Status List

Name systemStateSDCardDeviceStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.57
Description Lists the status of each SD Card device of this chassis. The results
are returned as a binary octet string where each byte of the octet
string represents the status of a SD Card device. The first byte
returned represents the status of the first SD Card device, and so on.
The bytes have the same definition type as DellStatus.
Syntax Octet String (Size(1..128))
Access Read-only

76 System State Group


book.book Page 77 Monday, March 14, 2011 3:01 PM

6
Chassis Information Group
The Chassis Information Group provides information about the type or types
of chassis in your system, as well as information about the light-emitting
diode (LED) indicators and settings for devices on each chassis. Information
is also available about the current date and time displayed on the chassis,
intrusion warnings, watchdog timer, systems management basic input/output
system (SMBIOS), and so on.

Chassis Information Group Tables


The following management information base (MIB) tables define the objects
in the Chassis Information Group:
• "Chassis Information Table" on page 77
• "UUID Table" on page 90
• "POST Log Table" on page 92
• "Event Log Table" on page 94
• "System BIOS Table" on page 97
• "Firmware Table" on page 104
• "Intrusion Table" on page 107
• "Baseboard Table" on page 109

Chassis Information Table


The following object sets up the Chassis Information Table.

Name chassisInformationTable
Object ID 1.3.6.1.4.1.674.10892.1.300.10
Description Defines the chassis information table.
Syntax SEQUENCE OF ChassisInformationTableEntry
Access Not accessible

Chassis Information Group 77


book.book Page 78 Monday, March 14, 2011 3:01 PM

Chassis Information Table Entry

Name chassisInformationTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1
Description Defines the chassis information table entry.
Syntax ChassisInformationTableEntry
Access Not accessible
Index chassisIndexChassisInformation

Chassis Index Chassis Information

Name chassisIndexChassisInformation
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.1
Description Defines the index (one-based) of this chassis. The first chassis is
numbered one.
Syntax DellObjectRange
Access Read-only

Chassis State Capabilities

Name chassisStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.2
Description Defines the capabilities of the chassis.
Syntax DellStateCapabilities
Access Read-only

Chassis State Settings

Name chassisStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.3
Description Defines the state settings for the chassis.
Syntax DellStateSettings
Access Read-write

78 Chassis Information Group


book.book Page 79 Monday, March 14, 2011 3:01 PM

Chassis Status

Name chassisStatus
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4
Description Defines the status of the chassis.
Syntax DellStatus
Access Read-only

Chassis Parent Index Reference

Name chassisparentIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4
Description Defines the index (one-based) of the parent chassis of this
chassis, if any. A zero (0) means that this chassis is the parent of
all other chassis managed by the Server Administrator.
Syntax DellObjectRange
Access Read-only

Chassis Type

Name chassisType
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.6
Description Defines the chassis type.
Syntax DellChassisType (See Table 6-2)
Access Read-only

Chassis Name

Name chassisName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.7
Description Defines the user-assigned chassis name of the chassis.
Syntax DellString
Access Read-write

Chassis Information Group 79


book.book Page 80 Monday, March 14, 2011 3:01 PM

Chassis Manufacturer Name

Name chassisManufacturerName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.8
Description Defines the manufacturer’s name for this chassis.
Syntax DellString
Access Read-only

Chassis Model Name

Name chassisModelName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.9
Description Defines the system model type for this chassis.
Syntax DellString
Access Read-only

Chassis Asset Tag Name

Name chassisAssetTagName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.10
Description Defines the user-assigned asset tag name for this chassis.
Syntax DisplayString (SIZE (0..10))
Access Read-write

Chassis Service Tag Name

Name chassisServiceTagName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.11
Description Defines the service tag name for this chassis.
Syntax DisplayString (SIZE (0..7))
Access Read-only

80 Chassis Information Group


book.book Page 81 Monday, March 14, 2011 3:01 PM

Chassis ID

Name chassisID
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.12
Description Defines the asset tag name for this chassis.
Syntax DellUnsigned8BitRange
Access Read-only

Chassis ID Extension

Name chassisIDExtension
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.13
Description Defines the SMBIOS machine ID of this chassis.
Syntax DellUnsigned16BitRange
Access Read-only

Chassis System Class

Name chassisSystemClass
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.14
Description Defines the chassis class of this chassis.
Syntax DellChassisSystemClass (See Table 6-21)
Access Read-only

Chassis System Name

Name chassisSystemName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.15
Description Defines the system name of this chassis.
Syntax DellString
Access Read-only

Chassis Information Group 81


book.book Page 82 Monday, March 14, 2011 3:01 PM

Chassis System Boot Date Name

Name chassisSystemBootDateName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.16
Description Defines the boot time of this system.
Syntax DellDateName
Access Read-only

Chassis System Date Name

Name chassisSystemDateName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.17
Description Defines the current time on this system.
Syntax DellDateName
Access Read-only

Chassis System Location Name

Name chassisSystemLocationName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.18
Description Defines the user-assigned location for this chassis.
Syntax DellString
Access Read-write

Chassis System Primary User Name

Name chassisSystemPrimaryUserName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.19
Description Defines the user-assigned primary user name for this chassis.
Syntax DellString
Access Read-write

82 Chassis Information Group


book.book Page 83 Monday, March 14, 2011 3:01 PM

Chassis System User Phone Number Name

Name chassisSystemUserPhoneNumberName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.20
Description Defines the user-assigned phone number of the primary user of
the system.
Syntax DellString
Access Read-write

Chassis Connection Status Unique

Name chassisConnectionStatusUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.21
Description Defines the status of the connection from the system chassis to
an expansion chassis.
Syntax DellConnectionStatus (See Table 6-3)
Access Read-only

Chassis Fan Control Capabilities Unique

Name chassisFanControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.22
Description Defines the capabilities of the fan control function in this chassis.
Syntax DellFanControlCapabilities (See Table 6-4)
Access Read-only

Chassis Fan Control Settings Unique

Name chassisFanControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.23
Description Defines the readings and settings of the fan control hardware in
the chassis.
Syntax DellFanControlSettings
Access Read-write

Chassis Information Group 83


book.book Page 84 Monday, March 14, 2011 3:01 PM

Chassis LED Control Capabilities Unique

Name chassisLEDControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.24
Description Defines the capabilities of the LED control function in the chassis.
Syntax DellLEDControlCapabilities (See Table 6-5)
Access Read-only

Chassis LED Control Settings Unique

Name chassisLEDControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.25
Description Defines the readings and settings of the LED control hardware
in the chassis.
Syntax DellLEDControlSettings (See Table 6-6)
Access Read-write

Chassis Hard-Drive (HD) Fault Clear Control Capabilities

Name chassisHDFaultClearControlCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.26
Description Specifies whether the chassis allows reset of the chassis
hard-drive fault LED.
Syntax DellHDFaultLEDControlCapabilities (See Table 6-7)
Access Read-only

Chassis HD Fault Clear Control Settings

Name chassisHDFaultClearControlSettings
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.27
Description Allows reset of the chassis hard-drive fault LED.
Syntax DellHDFaultLEDControlSettings (See Table 6-8)
Access Read-write

84 Chassis Information Group


book.book Page 85 Monday, March 14, 2011 3:01 PM

Chassis Identify Flash Control Capabilities

Name chassisIdentifyFlashControlCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.28
Description Specifies whether the chassis front-panel LED can be set to flash.
Syntax DellChassisIdentifyControlCapabilities (See Table 6-9)
Access Read-only

Chassis Identify Flash Control Settings

Name chassisIdentifyFlashControlSettings
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.29
Description Causes the chassis front-panel LED to flash.
Syntax DellChassisIdentifyControlSettings (See Table 6-10)
Access Read-write

Chassis Lock Present

Name chassisLockPresent
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.30
Description Specifies whether a chassis lock is present on the chassis.
Syntax DellBoolean
Access Read-only

Chassis Host Control Capabilities Unique

Name chassishostControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.31
Description Defines the capabilities of the host control object.
Syntax DellHostControlCapabilities (See Table 6-11)
Access Read-only

Chassis Information Group 85


book.book Page 86 Monday, March 14, 2011 3:01 PM

Chassis Host Control Settings Unique

Name chassishostControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.32
Description Defines the current settings of the host control object.
Syntax DellHostControlSettings (See Table 6-12)
Access Read-write

Chassis Watchdog Control Capabilities Unique

Name chassiswatchDogControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.33
Description Defines the capabilities of the watchdog timer object.
Syntax DellWatchDogControlCapabilities (See Table 6-13)
Access Read-only

Chassis Watchdog Control Settings Unique

Name chassiswatchDogControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.34
Description Defines the current settings and the values allowed to be set for
the watchdog timer object.
Syntax DellWatchDogControlCapabilities (See Table 6-13)
Access Read-write

Chassis Watchdog Control Expiry Time Capabilities Unique

Name chassiswatchDogControlExpiryTimeCapabilities
Unique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.35
Description Defines the capabilities of the watchdog expiry timer object.
Syntax DellWatchDogTimerCapabilities (See Table 6-13)
Access Read-only

86 Chassis Information Group


book.book Page 87 Monday, March 14, 2011 3:01 PM

Chassis Watchdog Control Expiry Time

Name chassiswatchDogControlExpiryTime
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.36
Description Defines the current reading and allows setting of the nonrecoverable
watchdog expiry timer object.
Syntax DellUnsigned16BitRange
Access Read-write

Chassis Allow Set Commands From SNMP

Name chassisallowSETCommandsfromSNMP
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.37
Description Specifies whether Simple Network Management Protocol (SNMP)
Set type commands are allowed by Server Administrator.
This attribute does not reflect whether SNMP Set type commands
are allowed by the SNMP master agent.
Syntax DellBoolean
Access Read-only

Chassis Power Button Control Capabilities Unique

Name chassisPowerButtonControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.38
Description Defines the capabilities of the power button control function.
Syntax DellPowerButtonControlCapabilities (See Table 6-16)
Access Read-only

Chassis Power Button Control Settings Unique

Name chassisPowerButtonControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.39
Description Defines the current reading and allows setting of the power button
control hardware.

Chassis Information Group 87


book.book Page 88 Monday, March 14, 2011 3:01 PM

Name chassisPowerButtonControlSettingsUnique
Syntax DellPowerButtonControlSettings (See Table 6-17)
Access Read-write

Chassis Reseller Name

Name chassisResellerName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.40
Description Defines the name of the chassis reseller.
Syntax DisplayString (SIZE (0..128))
Access Read-only

Chassis Reseller Contact Information Name

Name chassisResellerContactInformationName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.41
Description Defines the chassis reseller contact information name.
Syntax DisplayString (SIZE (0..128))
Access Read-only

Chassis Reseller Product Name

Name chassisResellerProductName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.42
Description Defines the chassis reseller product name.
Syntax DisplayString (SIZE (0..128))
Access Read-only

Chassis Reseller System ID

Name chassisResellerSystemID
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.43
Description Defines the chassis reseller system ID.

88 Chassis Information Group


book.book Page 89 Monday, March 14, 2011 3:01 PM

Name chassisResellerSystemID
Syntax DellUnsigned16BitRange
Access Read-only

Chassis NMI Button Control Capabilities Unique

Name chassisNMIButtonControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.44
Description Defines the capabilities of the NMI button control function.
Syntax DellNMIButtonControlCapabilities (See Table 6-18)
Access Read-only

Chassis NMI Button Control Settings Unique

Name chassisNMIButtonControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.45
Description Defines the current reading and allows setting of the NMI button
control hardware.
Syntax DellNMIButtonControlSettings (See Table 6-19)
Access Read-write

Chassis System Properties


Name chassisSystemProperties
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.46
Description Defines the properties of the system.
Syntax DellSystemProperties (See Table 6-20)
Access Read-only

Chassis Information Group 89


book.book Page 90 Monday, March 14, 2011 3:01 PM

Chassis System Revision Number

Name chassisSystemRevisionNumber
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.47
Description Defines the revision number of the system where zero indicates the
original version of the system. The revision number is not available
on all systems.
Syntax DellUnsigned8BitRange
Access Read-only

Chassis System Revision Name


Name chassisSystemRevisionName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.48
Description Defines the revision name of the system, if applicable.
Syntax DellString
Access Read-only

Chassis Express Service Code Name

Name chassisExpressServiceCodeName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.49
Description Defines the express service code of the chassis.
Syntax DellString
Access Read-only

UUID Table
These objects comprise the server administrator definitions for the
Universal Unique Identifier (UUID).

Name uUIDTable
Object ID 1.3.6.1.4.1.674.10892.1.300.20
Description Defines the UUID table.
Syntax SEQUENCE OF UUIDTableEntry

90 Chassis Information Group


book.book Page 91 Monday, March 14, 2011 3:01 PM

Name uUIDTable
Access Not accessible

UUID Table Entry

Name uUIDTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1
Description Defines the UUID table entry.
Syntax UUIDTableEntry
Access Not accessible
Index uUIDIndex, uUIDchassisIndex

UUID Chassis Index

Name uUIDchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

UUID Index

Name uUIDIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2
Description Defines the index of the UUID in a specified chassis.
Syntax DellObjectRange
Access Read-only

UUID Type

Name uUIDType
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3
Description Defines the type of the UUID for this chassis.

Chassis Information Group 91


book.book Page 92 Monday, March 14, 2011 3:01 PM

Name uUIDType
Syntax DellUUIDType
Access Read-only

UUID Value

Name uUIDValue
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4
Description Defines the value of the UUID for this chassis.
Syntax Octet String (SIZE(16))
Access Read-only

POST Log Table


This section defines attributes for the power-on self-test (POST) log.
When you turn on your computer, the POST checks various system
components before the operating system loads. The POST tests the
random-access memory (RAM), the hard drives, and the keyboard,
for example. While the POST is running, it makes a log file that system
administrators can view. The variables in this section also contribute to
managing the POST log.

Name postLogTable
Object ID 1.3.6.1.4.1.674.10892.1.300.30
Description Defines the POST Log Table.
Syntax SEQUENCE OF PostLogTableEntry
Access Not accessible

POST Log Table Entry

Name postLogTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.300.30.1
Description Defines the POST Log Table entry.
Syntax PostLogTableEntry

92 Chassis Information Group


book.book Page 93 Monday, March 14, 2011 3:01 PM

Name postLogTableEntry
Access Not accessible
Index postLogchassisIndex, postLogRecordIndex

POST Log Chassis Index

Name postLogchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

POST Log Record Index

Name postLogRecordIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.2
Description Defines the record number (one-based) of the POST log.
Syntax DellUnsigned32BitRange
Access Read-only

POST Log State Capabilities Unique

Name postLogStateCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.3
Description Defines the capabilities of the object that is writing the POST log.
Syntax DellStateCapabilitiesLogUnique
Access Read-only

POST Log State Settings Unique

Name postLogStateSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.4
Description Defines the state of the object that is writing the POST log.

Chassis Information Group 93


book.book Page 94 Monday, March 14, 2011 3:01 PM

Name postLogStateSettingsUnique
Syntax DellStateSettingsLogUnique
Access Read-write

POST Log Record

Name postLogRecord
Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5
Description Defines the data for the specified chassis and record index in the
POST log being returned.
Syntax DisplayString (SIZE (0..1024))
Access Read-only

POST Log Format

Name postLogFormat
Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5
Description Defines format of the POST log.
Syntax DellLogFormat (See Table 6-1)
Access Read-only

Event Log Table

Name eventLogTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.300.40
Description Defines the Event Log Table.
Syntax SEQUENCE OF EventLogTableEntry
Access Not accessible

Event Log Table Entry

Name eventLogTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1

94 Chassis Information Group


book.book Page 95 Monday, March 14, 2011 3:01 PM

Name eventLogTableEntry
Description Defines the event Log Table Entry.
Syntax EventLogTableEntry
Access Not accessible
Index eventLogchassisIndex,eventLogRecordIndex

Event Log Chassis Index

Name eventLogchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Event Log Record Index

Name eventLogRecordIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.2
Description Defines the record index of the event log.
Syntax DellUnsigned32BitRange
Access Read-only

Event Log State Capabilities Unique

Name eventLogStateCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.3
Description Defines the capabilities of the object that is writing the event log.
Syntax DellStateCapabilitiesLogUnique
Access Read-only

Chassis Information Group 95


book.book Page 96 Monday, March 14, 2011 3:01 PM

Event Log State Settings Unique

Name eventLogStateSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.4
Description Defines the state settings for the object that is writing the event log.
Syntax DellStateSettingsLogUnique
Access Read-write

Event Log Record

Name eventLogRecord
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.5
Description Defines the data for the specified chassis and log record index in the
event log being returned.
Syntax DisplayString (SIZE (0..1024))
Access Read-only

Event Log Format

Name eventLogFormat
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.6
Description Defines the format of the event log.
Syntax DellLogFormat (See Table 6-1)
Access Read-only

Event Log Severity Status

Name eventLogSeverityStatus
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.7
Description Defines the severity of the event log record.
Syntax DellStatus
Access Read-only
Status Mandatory

96 Chassis Information Group


book.book Page 97 Monday, March 14, 2011 3:01 PM

Event Log Date Name

Name eventLogDateName
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.8
Description Defines the date and time of the event log record.
Syntax DellDateName
Access Read-only
Status Mandatory

System BIOS Table


This table lists objects that define the system’s basic input/output system (BIOS).

Name systemBIOSTable
Object ID 1.3.6.1.4.1.674.10892.1.300.50
Description Defines the System BIOS Table.
Syntax SEQUENCE OF SystemBIOSTableEntry
Access Not accessible

System BIOS Table Entry

Name systemBIOSTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1
Description Defines the System BIOS Table entry.
Syntax SystemBIOSTableEntry
Access Not accessible
Index systemBIOSchassisIndex,systemBIOSIndex

System BIOS Chassis Index

Name systemBIOSchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange

Chassis Information Group 97


book.book Page 98 Monday, March 14, 2011 3:01 PM

Name systemBIOSchassisIndex
Access Read-only

System BIOS Index

Name systemBIOSIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.2
Description Defines the index (one-based) of the system BIOS of this object.
Syntax DellObjectRange
Access Read-only

System BIOS State Capabilities

Name systemBIOSStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.3
Description Defines the capabilities of the system BIOS of this object.
Syntax DellStateCapabilities
Access Read-only

System BIOS State Settings

Name systemBIOSStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.4
Description Defines the state of the system BIOS of this object.
Syntax DellStateSettings
Access Read-write

System BIOS Status

Name systemBIOSStatus
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.5
Description Defines the status of the system BIOS of this object.
Syntax DellStatus

98 Chassis Information Group


book.book Page 99 Monday, March 14, 2011 3:01 PM

Name systemBIOSStatus
Access Read-only

System BIOS Size

Name systemBIOSSize
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.6
Description Defines the image size of the system BIOS in kilobytes (KB).
A zero (0) indicates that the image size of the BIOS is unknown.
Syntax DellUnsigned32BitRange
Access Read-only

System BIOS Release Date Name

Name systemBIOSReleaseDateName
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.7
Description Defines the release date of the system BIOS.
Syntax DellDateName
Access Read-only

System BIOS Version Name

Name systemBIOSVersionName
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.8
Description Defines the version name of the system BIOS.
Syntax DellString
Access Read-only

System BIOS Starting Address

Name systemBIOSStartingAddress
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.9

Chassis Information Group 99


book.book Page 100 Monday, March 14, 2011 3:01 PM

Name systemBIOSStartingAddress
Description Defines the starting address of the system BIOS. A zero (0) indicates
that the address is unknown.
Syntax DellUnsigned64BitRange
Access Read-only

System BIOS Ending Address

Name systemBIOSEndingAddress
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.10
Description Defines the ending address of the system BIOS. A zero (0) indicates
that the address is unknown.
Syntax DellUnsigned64BitRange
Access Read-only

System BIOS Manufacturer Name

Name systemBIOSManufacturerName
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.11
Description Defines the system BIOS manufacturer’s name.
Syntax DellString
Access Read-only

System BIOS Characteristics

Name systemBIOSCharacteristics
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.12

100 Chassis Information Group


book.book Page 101 Monday, March 14, 2011 3:01 PM

Name systemBIOSCharacteristics
Description Defines characteristics of the system BIOS. This attribute is a bit
field where a bit has the meaning defined below when set to 1 (one).
Bit 63 is the first bit in the value, and bit 0 is the last bit in the value.
See the description of DellUnsigned64BitRange at the beginning of
this file for more information on the format of the value.
Bits 48-63 need to be examined in the context of the system ID.
The system ID is available in the attribute chassisID. If the value for
chassisID is non-zero, bits 48-63 have the meaning defined below:
Bit Position Meaning if Set
-------------- ------------------
Bit 0Reserved
Bit 1Reserved
Bit 2Unknown
Bit 3BIOS Characteristics Not Supported
Bit 4ISA is supported
Bit 5MCA is supported
Bit 6EISA is supported
Bit 7PCI is supported
Bit 8PC Card (PCMCIA) is supported
Bit 9Plug and Play is supported
Bit 10APM is supported
Bit 11BIOS is Upgradeable (Flash)
Bit 12BIOS shadowing is allowed
Bit 13VL-VESA is supported
Bit 14ESCD support is available
Bit 15Boot from CD is supported

Chassis Information Group 101


book.book Page 102 Monday, March 14, 2011 3:01 PM

Name systemBIOSCharacteristics
Description Bit Position Meaning if Set
-------------- ------------------
Bit 16Selectable Boot is supported
Bit 17BIOS ROM is socketed
Bit 18Boot From PC Card (PCMCIA) is supported
Bit 19EDD (Enhanced Disk Drive) Specification is supported
Bit 20Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in,
1k Bytes/Sector, 360 RPM) is supported
Bit 21Int 13h - Japanese Floppy for Toshiba 1.2mb (3.5 in,
360 RPM) is supported
Bit 22Int 13h - 5.25 in / 360 KB Floppy Services are supported
Bit 23Int 13h - 5.25 in /1.2MB Floppy Services are supported
Bit 24Int 13h - 3.5 in / 720 KB Floppy Services are supported
Bit 25Int 13h - 3.5 in / 2.88 MB Floppy Services are supported
Bit 26Int 5h, Print Screen Service is supported
Bit 27Int 9h, 8042 Keyboard services are supported
Bit 28Int 14h, Serial Services are supported
Bit 29Int 17h, Printer Services are supported
Bit 30Int 10h, CGA/Mono Video Services are supported
Bit 31NEC PC-98
Bit 32-47Reserved
Bit 48Built-in NIC supports Magic Packet
Bit 49System supports Wake-on-LAN
Bit 50System supports chassis intrusion
Bit 51Built-in NIC supports pattern-matching
Bit 52System BIOS supports a 7-character service tag
Bit 53-63Reserved
Syntax DellUnsigned64BitRange

102 Chassis Information Group


book.book Page 103 Monday, March 14, 2011 3:01 PM

System BIOS Characteristics Ext 1

Name systemBIOSCharacteristicsExt1
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.13
Description Defines additional characteristics of the system basic input/output
system (BIOS). This attribute is a bit field where a bit has the
meaning defined below when set to 1 (one).
Bit Position Meaning if Set
-------------- ------------------
Bit 0ACPI supported
Bit 1USB Legacy is supported
Bit 2AGP is supported
Bit 3I2O boot is supported
Bit 4LS-120 boot is supported
Bit 5ATAPI ZIP Drive boot is supported
Bit 61394 boot is supported
Bit 7Smart Battery supported
Syntax DellUnsigned8BitRange
Access Read-only

System BIOS Characteristics Ext 2

Name systemBIOSCharacteristicsExt2
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.14
Description Defines additional characteristics of the system BIOS.
This attribute is a bit field where a bit has the meaning defined
below when set to 1 (one).
Bit Position Meaning if Set
--------------- --------------------
Bit 0BIOS Boot Specification supported
Bit 1Function key-initiated Network Service boot supported
Bit 2Targeted Content Distribution supported
Bit 3-7Reserved
Syntax DellUnsigned8BitRange
Access Read-only

Chassis Information Group 103


book.book Page 104 Monday, March 14, 2011 3:01 PM

Firmware Table

Name firmwareTable
Object ID 1.3.6.1.4.1.674.10892.1.300.60
Description Defines the Firmware Table.
Syntax SEQUENCE OF FirmwareTableEntry
Access Not accessible

Firmware Table Entry

Name firmwareTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1
Description Defines the Firmware Table entry.
Syntax FirmwareTableEntry
Access Not accessible
Index firmwarechassisIndex, firmwareIndex

Firmware Chassis Index

Name firmwarechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Firmware Index

Name firmwareIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.2
Description Defines the index (one-based) of the firmware in this chassis.
Syntax DellObjectRange
Access Read-only

104 Chassis Information Group


book.book Page 105 Monday, March 14, 2011 3:01 PM

Firmware State Capabilities

Name firmwareStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.3
Description Defines the capabilities of the firmware states.
Syntax DellStateCapabilities
Access Read-only

Firmware State Capabilities

Name firmwareStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.4
Description Defines the state of the firmware and allows for the setting of the
firmware.
Syntax DellStateSettings
Access Read-write

Firmware Status

Name firmwareStatus
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.5
Description Defines the status of the firmware.
Syntax DellStateSettings
Access Read-only

Firmware Size

Name firmwareSize
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.6
Description Defines the image size of the firmware in KB. A zero (0) indicates
that the size is unknown.
Syntax DellUnsigned16BitRange
Access Read-only

Chassis Information Group 105


book.book Page 106 Monday, March 14, 2011 3:01 PM

Firmware Type

Name firmwareType
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.7
Description Defines the type of the firmware.
Syntax DellFirmwareType
Access Read-only

Firmware Type Name

Name firmwareTypeName
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.8
Description Defines the name of firmware type.
Syntax DellString
Access Read-only

Firmware Update Capabilities

Name firmwareUpdateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.9
Description Defines the bitmap of supported methods for firmware update.
Syntax DellUnsigned16BitRange
Access Read-only

Firmware Date Name

Name firmwareDateName
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.10
Description Defines the date of the firmware.
Syntax DellDateName
Access Read-only

106 Chassis Information Group


book.book Page 107 Monday, March 14, 2011 3:01 PM

Firmware Version Name

Name firmwareVersionName
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.11
Description Defines the version name of the firmware.
Syntax DellString
Access Read-only

Intrusion Table
The following objects and attributes describe the different forms of chassis
intrusion, a situation that occurs when the cover of a computer is removed.

Name intrusionTable
Object ID 1.3.6.1.4.1.674.10892.1.300.70
Description Defines the Intrusion Table.
Syntax SEQUENCE OF IntrusionTableEntry
Access Not accessible

Intrusion Table Entry

Name intrusionTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1
Description Defines the Intrusion Table entry.
Syntax IntrusionTableEntry
Access Not accessible
Index intrusionchassisIndex, intrusionIndex

Intrusion Chassis Index

Name intrusionchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Chassis Information Group 107


book.book Page 108 Monday, March 14, 2011 3:01 PM

Intrusion Index

Name intrusionIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.2
Description Defines the index of the intrusion objects in this subgroup.
Syntax DellObjectRange
Access Read-only

Intrusion State Capabilities

Name intrusionStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.3
Description Defines the capabilities of the intrusion object.
Syntax DellStateCapabilities
Access Read-only

Intrusion State Settings

Name intrusionStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.4
Description Defines the settings of the intrusion object.
Syntax DellStateSettings
Access Read-write

Intrusion Status

Name intrusionStatus
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.5
Description Defines the status of the intrusion object.
Syntax DellStatus
Access Read-only

108 Chassis Information Group


book.book Page 109 Monday, March 14, 2011 3:01 PM

Intrusion Reading

Name intrusionReading
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.6
Description Defines the reading of the intrusion object.
Syntax DellIntrusionReading
Access Read-only

Intrusion Type

Name intrusionType
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.7
Description Defines the type of the intrusion object.
Syntax DellIntrusionType
Access Read-only

Intrusion Location Name

Name intrusionLocationName
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.8
Description Defines the location name of the intrusion object in this subgroup.
Syntax DellString
Access Read-only

Baseboard Table
This table lists objects that define the baseboard of a system.

Name baseBoardTable
Object ID 1.3.6.1.4.1.674.10892.1.300.80
Description Defines the Baseboard Table.
Syntax SEQUENCE OF BaseBoardTableEntry
Access Not accessible

Chassis Information Group 109


book.book Page 110 Monday, March 14, 2011 3:01 PM

Baseboard Table Entry

Name baseBoardTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1
Description Defines the Baseboard Table entry.
Syntax BaseBoardTableEntry
Access Not accessible
Index baseBoardChassisIndex, baseBoardIndex

Baseboard Chassis Index

Name baseBoardChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellObjectRange
Access Read-only

Baseboard Index

Name baseBoardIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.2
Description Defines the index (one-based) of the base board.
Syntax DellObjectRange
Access Read-only

Baseboard State Capabilities

Name baseBoardStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.3
Description Defines the state capabilities of the baseboard.
Syntax DellStateCapabilities
Access Read-only

110 Chassis Information Group


book.book Page 111 Monday, March 14, 2011 3:01 PM

Baseboard State Settings

Name baseBoardStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.4
Description Defines the state settings of the baseboard.
Syntax DellStateSettings
Access Read-write

Baseboard Status

Name baseBoardStatus
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.5
Description Defines the status of the baseboard.
Syntax DellStatus
Access Read-only

Baseboard Feature Flags

Name baseBoardFeatureFlags
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.6
Description Defines the features of the baseboard.
Syntax DellBaseBoardFeatureFlags
Access Read-only

Baseboard Type

Name baseBoardType
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.7
Description Defines the type of the baseboard.
Syntax DellBaseBoardType
Access Read-only

Chassis Information Group 111


book.book Page 112 Monday, March 14, 2011 3:01 PM

Baseboard Type Name

Name baseBoardTypeName
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.8
Description Defines the name of the type of baseboard.
Syntax DellString
Access Read-only

Baseboard Location Name

Name baseBoardLocationName
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.9
Description Defines the location name of the baseboard.
Syntax DellString
Access Read-only

Baseboard Manufacturer Name

Name baseBoardManufacturerName
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.10
Description Defines the baseboard manufacturer’s name.
Syntax DellString
Access Read-only

Baseboard Product Name

Name baseBoardProductName
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.11
Description Defines the baseboard product’s name.
Syntax DellString
Access Read-only

112 Chassis Information Group


book.book Page 113 Monday, March 14, 2011 3:01 PM

Baseboard Version Name

Name baseBoardVersionName
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.12
Description Defines the baseboard version name.
Syntax DellString
Access Read-only

Baseboard Service Tag Name

Name baseBoardServiceTagName
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.13
Description Defines the baseboard service tag name.
Syntax DellString
Access Read-only

Baseboard Piece Part ID (PPID) Name

Name baseBoardPiecePartIDName
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.14
Description Defines the baseboard PPID.
Syntax DellString
Access Read-only

Baseboard Asset Tag Name

Name baseBoardAssetTagName
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.15
Description Defines the baseboard asset tag name.
Syntax DellString
Access Read-only

Chassis Information Group 113


book.book Page 114 Monday, March 14, 2011 3:01 PM

Baseboard Express Service Code Name


Name baseBoardExpressServiceCodeName
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.16
Description Defines the express service code of the baseboard.
Syntax DellString
Access Read-only

Chassis Information Group Variable Values


This section includes definitions for server administrator-specific variable
values used in this section.

Table 6-1. Log Format

Variable Name: DellLogFormat


Data Type: Integer
Possible Data Values Meaning of Data Value
raw(1) The log is in the format received from the
firmware.
ascii(2) The log is in ASCII format.
uniCode(3) The log is in Unicode format.

Table 6-2. Chassis Type

Variable Name: DellChassisType


Data Type: Integer
Possible Data Values Meaning of Data Value
other(1) The chassis type is not one of the following:
unknown(2) The chassis type is unknown.
desktop(3) The chassis type is a desktop.
lowProfileDesktop(4) The chassis type is a low-profile desktop.
pizzaBox(5) The chassis type is a pizza box.
miniTower(6) The chassis type is a minitower.

114 Chassis Information Group


book.book Page 115 Monday, March 14, 2011 3:01 PM

Table 6-2. Chassis Type (continued)

Variable Name: DellChassisType


Data Type: Integer
Possible Data Values Meaning of Data Value
tower(7) The chassis type is a tower.
portable(8) The chassis type is a portable.
lapTop(9) The chassis type is a laptop.
noteBook(10) The chassis type is a notebook.
handHeld(11) The chassis type is a handheld.
dockingStation(12) The chassis type is a docking station.
allInOne(13) The chassis type is an all-in-one.
subNoteBook(14) The chassis type is a subnotebook.
spaceSaving(15) The chassis type is a spacesaver.
lunchBox(16) The chassis type is a lunch box.
mainSystemChassis(17) The chassis type is the main system chassis.
expansionChassis(18) The chassis type is an expansion chassis.
subChassis(19) The chassis type is a subchassis.
busExpansionChassis(20) The chassis type is a bus-expansion chassis.
peripheralChassis(21) The chassis type is a peripheral chassis.
raidChassis(22) The chassis type is a disk RAID chassis.
rackMountChassis(23) The chassis type is a rack-mounted chassis.
sealedCasePC(24) The chassis type is a sealed-case chassis.
multiSystemChassis(25) The chassis type is a multisystem chassis.

Chassis Information Group 115


book.book Page 116 Monday, March 14, 2011 3:01 PM

Table 6-3. Connection Status

Variable Name: DellConnectionStatus


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(2) The status of the chassis connection is
unknown.
ok(3) The status of the chassis connection is OK.
failure(4) The status of the chassis connection is
failure.

Table 6-4. Fan Control Capabilities

Variable Name: DellFanControlCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The fan’s capabilities are unknown.
lowSpeedCapable(2) The fan can be set to low speed.
highSpeedCapable(4) The fan can be set to high speed.
lowOrhighSpeedCapable(6) The fan can be set to low or high speed.

Table 6-5. Front-Panel LED Control Capabilities

Variable Name: DellLEDControlCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The LED control capabilities are unknown.
alertOnErrorCapable(2) The LED control can be set to alert on an
error condition.
alertOnWarningAndErrorCap The LED control can be set to alert on an
able(4) error and a warning condition.
alertOnWarningOrErrorCapa The LED control can be set to alert on an
ble(6) error or a warning condition.

116 Chassis Information Group


book.book Page 117 Monday, March 14, 2011 3:01 PM

Table 6-6. Front-Panel LED Control Settings

Variable Name: DellLEDControlSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The LED control setting is unknown.
alertOnError(2) The LED control is set to alert on an error
condition.
alertOnWarningAndError(4) The LED control is set to alert on an error or
a warning condition.

Table 6-7. Hard-Drive Fault LED Control Capabilities

Variable Name: DellHDFaultLEDControlCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The hard drive has no fault LED
capabilities.
unknownCapabilities(1) The hard-drive fault LED capabilities are
unknown.
enableCapable(2) The hard-drive fault LED can be disabled
(offline, a binary 0 value) or enabled (online,
a binary 1 value).
notReadyCapable(4) The hard-drive fault LED can indicate not
ready.
resetCapable(8) The hard-drive fault LED can be reset.

Chassis Information Group 117


book.book Page 118 Monday, March 14, 2011 3:01 PM

Table 6-8. Hard-Drive Fault LED Control Settings

Variable Name: DellHDFaultLEDControlSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The LEDs do not have any fault settings
capabilities.
unknown(1) The hard-drive fault LEDs’ state is
unknown.
enabled(2) The hard-drive fault LEDs’ state is disabled
(offline, a binary 0 value) or enabled (online,
a binary 1 value).
notReady(4) The hard-drive fault LEDs’ state is not ready.
reset(8) The hard-drive fault LEDs have been reset.
resetAndEnable(10) The hard-drive fault LEDs have been reset
and enabled.

Table 6-9. Chassis Identification Control Capabilities

Variable Name: DellChassisIdentifyControlCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The LEDs do not have any chassis
identification capabilities.
unknownCapabilities(1) The chassis identification control’s
capabilities are unknown.
enableCapable(2) The chassis identification controls can be
disabled (offline, a binary 0 value) or
enabled (online, a binary 1 value).
notReadyCapable(4) The chassis identification control’s
capabilities are not ready.
identifyCapable(8) The chassis identification control’s LEDs
can be made to identify the chassis.

118 Chassis Information Group


book.book Page 119 Monday, March 14, 2011 3:01 PM

Table 6-9. Chassis Identification Control Capabilities (continued)

Variable Name: DellChassisIdentifyControlCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
NOTE: Chassis identification capabilities allow system administrators to set front
panel light-emitting diodes (LEDs) to blink when the chassis has malfunctioning
components. When enabled, the blinking lights help administrators locate the
problem chassis.

Table 6-10. Chassis Identification Control Settings

Variable Name: DellChassisIdentifyControlSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The chassis identification control’s state is
unknown.
enabled(2) The chassis identification control’s state is
disabled (offline, a binary 0 value) or
enabled (online, a binary 1 value).
notReady(4) The chassis identification control’s state
is not ready.
identifyChassis(8) The chassis identification control’s
LEDs may be returned to (normal) 0,
or (identify chassis) 1.
identifyChassisAndEnable The chassis identification control’s
(10) LEDs may be returned to normal
(a binary 0 value), or identify chassis
and enabled (a binary 1 value).

Chassis Information Group 119


book.book Page 120 Monday, March 14, 2011 3:01 PM

Table 6-11. Host Control Capabilities

Variable Name: DellHostControlCapabilities


NOTE: An operator can manually enable these actions using SNMP.
Data Type: Integer
Possible Data Values Meaning of Data Value
manualRebootCapable(1) The operator can reboot capable host.
manualPowerOFFCapable(2) The operator can power off capable host.
manualPowerCycleCapable(4) The operator can power-cycle capable
host.
manualAllExceptOperating The operator can reboot and power off
SystemShutdownCapable(7) capable host.
manualOperatingSystemShut The operator can shut down the
downCapable(8) operating-system–shutdown capable host.
manualFullyCapable(15) The operator can reboot, power on and off
the power-cycle capable host, and shut
down the operating-system–shutdown
capable host.
manualRebootWithOSShutdow The operator can reboot with operating
nCapable(16) system shutdown.
manualRebootWithoutOSShut The operator can reboot without
downCapable(32) operating system shutdown.
manualPowerOffWithOSShutd The operator can power off with operating
ownCapable(64) system shutdown.
manualPowerOffWithoutOSSh The operator can power off without
utdownCapable(128) operating system shutdown.
manualPowerCycleWithOSShu The operator can power cycle with
tdownCapable(256) operating system shutdown.
manualPowerCycleWithoutOS The operator can power cycle without
ShutdownCapable(512) operating system shutdown.

120 Chassis Information Group


book.book Page 121 Monday, March 14, 2011 3:01 PM

Table 6-12. Host Control Settings

Variable Name: DellHostControlSettings


NOTE: An operator can manually cause these actions using SNMP.
Data Type: Integer
Possible Data Values Meaning of Data Value
manualReboot(1) The operator can reboot the host.
manualPowerOFF(2) The operator can power off the host.
manualPowerCycle(4) Power cycle the host.
manualOperatingSystemShutdown(8) The operator can shut down the
operating system on the host.
manualOperatingSystemShutdownThe The operator can shut down the
nPowerCycle(12) operating system on the host then
power cycle machine.

Table 6-13. Watchdog Control Capabilities

Variable Name: DellWatchDogControlCapabilities


NOTE: When the system determines that the operating system is not responding, it
automatically performs the selected action without operator intervention.
Data Type: Integer
Possible Data Values Meaning of Data Value
automaticRebootCapable(1) Watchdog controls can be set to
reboot capable host.
automaticPowerCycleCapable(2) Watchdog controls can be set to
power cycleable capable host.
automaticNotificationCapable(4) Watchdog controls can be set to
notify capable host.
automaticWatchDogTimerCapable(8) Watchdog controls can be set to
function automatically.
automaticPowerOffCapable(16) Watchdog controls can be set to
automatically power off host.

Chassis Information Group 121


book.book Page 122 Monday, March 14, 2011 3:01 PM

Table 6-13. Watchdog Control Capabilities (continued)

Variable Name: DellWatchDogControlCapabilities


NOTE: When the system determines that the operating system is not responding, it
automatically performs the selected action without operator intervention.
Data Type: Integer
Possible Data Values Meaning of Data Value
automaticAllExceptNotificationCap Watchdog controls can be set to
able(27) automatically perform all functions
except notification capable.
automaticFullyCapable(31) Watchdog controls can be set to
automatically perform all functions.

Table 6-14. Watchdog Control Settings

Variable Name: DellWatchControlSettings


NOTE: The watchdog timer is the mechanism used by a chassis to determine if the
operating system has stopped responding.
Data Type: Integer
Possible Data Values Meaning of Data Value
automaticRebootEnabled(1) Automatic reboot is enabled for this
host.
automaticPowerCycleEnabled(2) Automatic power cycleable is enabled
for this host.
automaticNotificationEnabled(4) Automatic notification is enabled for
this host.
automaticPowerOffEnabled(8) Automatic power off is enabled for
this host.

122 Chassis Information Group


book.book Page 123 Monday, March 14, 2011 3:01 PM

Table 6-15. Watchdog Timer Capabilities

Variable Name: DellWatchDogTimerCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
type1Capable(1) Watchdog timer can time in intervals from
20–480 seconds.
type2Capable(2) Watchdog timer can time in 30-, 60-, 120-, and
480-second intervals.
type3Capable(4) Watchdog timer can time in 60-second intervals.

Table 6-16. Power Button Control Capabilities

Variable Name: DellPowerButtonControlCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The power button has no capabilities.
unknownCapabilities(1) The power button capabilities are unknown.
enableCapable(2) The power button can be enabled (online) or
disabled (offline).

Table 6-17. Power Button Control Settings

Variable Name: DellPowerButtonControlSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The power button has no settings capabilities.
unknown(1) The power button settings are unknown.
enabled(2) The power button state is enabled.
disabled(4) The power button state is disabled.

Chassis Information Group 123


book.book Page 124 Monday, March 14, 2011 3:01 PM

Table 6-18. NMI Button Control Capabilities

Variable Name: DellNMIButtonControlCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The NMI button has no capabilities.
unknownCapabilities(1) The NMI button capabilities are unknown.
enableCapable(2) The NMI button can be enabled (online) or
disabled (offline).

Table 6-19. NMI Button Control Settings

Variable Name: DellNMIButtonControlSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The NMI button has no settings capabilities.
unknown(1) The NMI button settings are unknown.
enabled(2) The NMI button state is enabled.
disabled(4) The NMI button state is disabled.

Table 6-20. System Properties


Variable Name: DellSystemProperties
NOTE: These values are bit masks, so combination values are possible.
Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) No properties.
energySmart(1) The system is an Energy Smart System.

124 Chassis Information Group


book.book Page 125 Monday, March 14, 2011 3:01 PM

Table 6-21. Chassis System Class

Variable Name: DellChassisSystemClass


Data Type: Integer
Possible Data Values Meaning of Data Value
other(1) The chassis system class is not one of the following:
unknown(2) The chassis system class is unknown.
workstationClass(3) The chassis system class is a workstation.
serverClass(4) The chassis system class is a server.
desktopClass(5) The chassis system class is a desktop.
portableClass(6) The chassis system class is a portable.
netPCClass(7) The chassis system class is a Net PC.
storageClass(8) The chassis system class is storage.

Table 6-22. Firmware Type

Variable Name: DellFirmwareType


Data Type: Integer
Possible Data Values Meaning of Data Value
other(1) The firmware type is other than
following values.
unknown(2) The firmware type is unknown.
systemBIOS(3) The firmware type is System BIOS
embeddedSystemManagementContro The firmware type is Embedded
ller(4) System Management Controller.
powerSupplyParallelingBoard(5) The firmware type is Power Supply
Paralleling Board.
systemBackPlane(6) The firmware type is System
(Primary) Backplane.
powerVault2XXSKernel(7) The firmware type is Dell
PowerVault 2XXS Kernel.
powerVault2XXSApplication(8) The firmware type is PowerVault
2XXS Application.

Chassis Information Group 125


book.book Page 126 Monday, March 14, 2011 3:01 PM

Table 6-22. Firmware Type (continued)

Variable Name: DellFirmwareType


Data Type: Integer
Possible Data Values Meaning of Data Value
frontPanel(9) The firmware type is Front Panel
Controller.
baseboardManagementController The firmware type is Baseboard
(10) Management Controller.
hotPlugPCI(11) The firmware type is Hot Plug
Peripheral Component Interconnect
(PCI) Controller.
sensorData(12) The firmware type is Sensor Data
Records.
peripheralBay(13) The firmware type is Peripheral Bay
Backplane.
secondaryBackPlane(14) The firmware type is Secondary
Backplane for ESM 2 systems.
secondaryBackPlaneESM3And4(15) The firmware type is Secondary
Backplane for ESM 3 and 4 systems.
rac(16) The firmware type is Remote
Access Controller.
iDRAC(17) The firmware type is Integrated
Dell Remote Access Controller.
unifiedServerConfigurator(19) The firmware type is Unified Server
Configurator.
lifecycleController(20) The firmware type is Lifecycle
Controller.

126 Chassis Information Group


book.book Page 127 Monday, March 14, 2011 3:01 PM

Table 6-23. Baseboard Type

Variable Name: DellBaseBoardType


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The baseboard type is unknown.
other(2) The baseboard type is not one of the
following types.
serverBlade(3) The baseboard type is a server blade.
connectivitySwitch(4) The baseboard type is a connectivity switch.
systemManagementModule(5) The baseboard type is a system management
module.
processorModule(6) The baseboard type is a processor module.
ioModule(7) The baseboard type is an I/O module.
memoryModule(8) The baseboard type is a memory module
daughterBoard(9) The baseboard type is a daughter board.
motherboard(10) The baseboard type is a mother board.
processorMemoryModule(11) The baseboard type is a processor or memory
module
processorIOModule(12) The baseboard type is a processor or
I/O module
interconnectBoard(13) The baseboard type is an interconnect board.

Table 6-24. Baseboard Feature Flags

Variable Name: DellBaseBoardFeatureFlags


Data Type: Integer
Possible Data Values Meaning of Data Value
NOTE: These values are bit fields, so combination values are possible.
no features(0) This baseboard has no feature flags.
boardIsHostingBoard(1) This baseboard is a hosting board.

Chassis Information Group 127


book.book Page 128 Monday, March 14, 2011 3:01 PM

Table 6-24. Baseboard Feature Flags

Variable Name: DellBaseBoardFeatureFlags


Data Type: Integer
Possible Data Values Meaning of Data Value
boardRequiresDaughterBoard This baseboard requires at least one
(2) daughter board or auxiliary card.
boardIsRemovable(4) This baseboard is removable.
boardIsReplaceable(8) This baseboard is replaceable.
boardIsHotSwappable(16) This baseboard is hot swappable.

128 Chassis Information Group


book.book Page 129 Monday, March 14, 2011 3:01 PM

7
Operating System Group
The Operating System Group provides status and identifying information
about a system’s operating system. Identifying information includes the
name, version, service pack, and patch level of the installed operating system.

Operating System Group Table


The following management information base (MIB) tables define the objects
in the Operating System Group:
• "Operating System Table" on page 129
• "Operating System Memory Table" on page 131

Operating System Table


The following object sets up the Operating System Table.

Name operatingSystemTable
Object ID 1.3.6.1.4.1.674.10892.1.400.10
Description Defines the Operating System Table.
Syntax SEQUENCE OF OperatingSystemTableEntry
Access Not accessible

Operating System Table Entry

Name operatingSystemTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.400.10.1
Description Defines the Operating System Table entry.
Syntax OperatingSystemTableEntry
Access Not accessible
Index operatingSystemchassisIndex

Operating System Group 129


book.book Page 130 Monday, March 14, 2011 3:01 PM

Operating System Chassis Index

Name operatingSystemchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellObjectRange
Access Read-only

Operating System State Capabilities

Name operatingSystemStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.2
Description Defines the capabilities of the operating system.
Syntax DellStateCapabilities
Access Read-only

Operating System State Settings

Name operatingSystemStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.3
Description Defines the state of the operating system.
Syntax DellStateSettings
Access Read-write

Operating System Status

Name operatingSystemStatus
Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.4
Description Defines the status of the operating system.
Syntax DellStatus
Access Read-only

130 Operating System Group


book.book Page 131 Monday, March 14, 2011 3:01 PM

Operating System Is Primary

Name operatingSystemIsPrimary
Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.5
Description Specifies whether this operating system is the primary operating
system.
Syntax DellBoolean
Access Read-only

Operating System Name

Name operatingSystemOperatingSystemName
Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.6
Description Defines the name of the operating system running on the system.
Syntax DisplayString (SIZE (0..255))
Access Read-only

Operating System Version Name

Name operatingSystemOperatingSystemVersionName
Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.7
Description Defines the version of the operating system running on the
system.
Syntax DisplayString (SIZE (0..255))
Access Read-only

Operating System Memory Table

Name operatingSystemMemoryTable
Object ID 1.3.6.1.4.1.674.10892.1.400.20
Description Defines the Operating System Memory Table.
Syntax SEQUENCE OF OperatingSystemMemoryTableEntry
Access Not accessible

Operating System Group 131


book.book Page 132 Monday, March 14, 2011 3:01 PM

Operating System Memory Table Entry

Name operatingSystemTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1
Description Defines the Operating System Memory Table entry.
Syntax OperatingSystemMemoryTableEntry
Access Not accessible
Index operatingSystemMemorychassisIndex

Operating System Memory Chassis Index

Name operatingSystemMemorychassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Operating System Memory State Capabilities

Name operatingSystemMemoryStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.2
Description Defines the capabilities of the operating system memory.
Syntax DellStateCapabilities
Access Read-only

Operating System Memory State Settings

Name operatingSystemMemoryStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.3
Description Defines the state and allows the setting of the operating system
memory.
Syntax DellStateSettings
Access Read-write

132 Operating System Group


book.book Page 133 Monday, March 14, 2011 3:01 PM

Operating System Memory Status

Name operatingSystemMemoryStatus
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.4
Description Defines the status of the operating system memory.
Syntax DellStatus
Access Read-only

Operating System Memory Total Physical Size

Name operatingSystemMemoryTotalPhysicalSize
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.5
Description Defines the total physical memory size in kilobytes.
Syntax DellUnsigned32BitRange
Access Read-only

Operating System Memory Available Physical Size

Name operatingSystemMemoryAvailablePhysicalSize
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.6
Description Defines the available physical memory size in kilobytes.
Syntax DellUnsigned32BitRange
Access Read-only

Operating System Memory Total Page File Size

Name operatingSystemMemoryTotalPageFileSize
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.7
Description Defines the total page file memory size in kilobytes.
Syntax DellUnsigned32BitRange
Access Read-only

Operating System Group 133


book.book Page 134 Monday, March 14, 2011 3:01 PM

Operating System Memory Available Page File Size

Name operatingSystemMemoryAvailablePageFileSize
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.8
Description Defines the available page file memory size in kilobytes.
Syntax DellUnsigned32BitRange
Access Read-only

Operating System Memory Total Virtual Size

Name operatingSystemMemoryTotalVirtualSize
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.9
Description Defines the total virtual memory size in kilobytes.
Syntax DellUnsigned32BitRange
Access Read-only

Operating System Memory Available Virtual Size

Name operatingSystemMemoryAvailableVirtualSize
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.10
Description Defines the available virtual memory size in kilobytes.
Syntax DellUnsigned32BitRange
Access Read-only

134 Operating System Group


book.book Page 135 Monday, March 14, 2011 3:01 PM

8
System Resource Group
The Management Information Base (MIB) variables presented in this section
enable you to track various attributes of your system resources. This section
includes "System Resource Group Tables" on page 135 that track variables
such as the owner, ports, system memory, interrupts, and direct memory
access.

System Resource Group Tables


The following MIB tables define objects for the System Resource Group:
• "System Resource Map Table" on page 135
• "System Resource Owner Table" on page 137
• "System Resource Input/Output (I/O) Port Table" on page 140
• "System Resource Memory Table" on page 143
• "System Resource Interrupt Table" on page 146
• "System Resource Direct Memory Access (DMA) Table" on page 149

System Resource Map Table

Name systemResourceMapTable
Object ID 1.3.6.1.4.1.674.10892.1.500.10
Description Defines the System Resource Map Table.
Syntax SEQUENCE OF SystemResourceMapTableEntry
Access Not accessible

System Resource Group 135


book.book Page 136 Monday, March 14, 2011 3:01 PM

System Resource Map Table Entry

Name systemResourceMapTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.500.10.1
Description Defines the System Resource Map Table entry.
Syntax SystemResourceMapTableEntry
Access Not accessible
Index systemResourceMapchassisIndex, systemResourceMapIndex

System Resource Map Chassis Index

Name systemResourceMapChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

System Resource Map Index

Name systemResourceMapIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.2
Description Defines the index of system resource maps in this chassis.
Syntax DellObjectRange
Access Read-only

System Resource Map State Capabilities

Name systemResourceMapStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.3
Description Defines the capabilities of this system map.
Syntax DellStateCapabilities
Access Read-only

136 System Resource Group


book.book Page 137 Monday, March 14, 2011 3:01 PM

System Resource Map State Settings

Name systemResourceMapStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.4
Description Defines the state and allows the setting of this system map.
Syntax DellStateSettings
Access Read-write

System Resource Map Status

Name systemResourceMapStatus
Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.5
Description Defines the status of this system map.
Syntax DellStatus
Access Read-only

System Resource Map Type

Name systemResourceMapType
Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.6
Description Defines the type of this system map.
Syntax DellSystemResourceMapType (See Table 8-1)
Access Read-only

System Resource Owner Table

Name systemResourceOwnerTable
Object ID 1.3.6.1.4.1.674.10892.1.500.20
Description Defines the System Resource Owner Table.
Syntax SEQUENCE OF SystemResourceOwnerTableEntry
Access Not accessible

System Resource Group 137


book.book Page 138 Monday, March 14, 2011 3:01 PM

System Resource Owner Table Entry

Name systemResourceOwnerTable
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1
Description Defines the System Resource Owner Table entry. Variables in
this group reference the System Resource Map index.
Syntax SystemResourceOwnerTableEntry
Access Not accessible
Index systemResourceOwnerchassisIndex,
systemResourceOwnerIndex

System Resource Owner Chassis Index

Name systemResourceOwnerchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

System Resource Owner Index

Name systemResourceOwnerIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.2
Description Defines the index of system resource owners for this chassis.
Syntax DellObjectRange
Access Read-only

System Resource Owner State Capabilities

Name systemResourceOwnerStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.3
Description Defines the capabilities of this system resource owner.
Syntax DellStateCapabilities
Access Read-only

138 System Resource Group


book.book Page 139 Monday, March 14, 2011 3:01 PM

System Resource Owner State Settings

Name systemResourceOwnerStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.4
Description Defines the state settings of this system resource owner.
Syntax DellStateSettings
Access Read-write

System Resource Owner Status

Name systemResourceOwnerStatus
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.5
Description Defines the status of this system resource owner.
Syntax DellStatus
Access Read-write

System Resource Owner Interface Type

Name systemResourceOwnerInterfaceType
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.6
Description Defines the interface type for this system resource owner.
Syntax DellResourceOwnerInterfaceType (See Table 8-2)
Access Read-only

System Resource Map Index Reference

Name systemResourceMapIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.7
Description Defines the index to the associated system resource map in this
chassis.
Syntax DellObjectRange
Access Read-only

System Resource Group 139


book.book Page 140 Monday, March 14, 2011 3:01 PM

System Resource Owner Description Name

Name systemResourceOwnerDescriptionName
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.8
Description Defines the description name of the system resource owner.
Syntax DellString
Access Read-only

System Resource Owner Interface Instance

Name systemResourceOwnerInterfaceInstance
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.9
Description Defines the associated system resource owner interface instance
in this chassis.
Syntax DellObjectRange
Access Read-only

System Resource Input/Output (I/O) Port Table

Name systemResourceIOPortTable
Object ID 1.3.6.1.4.1.674.10892.1.500.30
Description Defines the System Resource I/O Port Table.
Syntax SEQUENCE OF SystemResourceIOPortTableEntry
Access Not accessible

System Resource I/O Port Table Entry

Name systemResourceIOPortTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1
Description Defines the System Resource I/O Port Table entry.
Syntax SystemResourceIOPortTableEntry
Access Not accessible
Index systemResourceIOPortchassisIndex,
systemResourceIOPortIndex

140 System Resource Group


book.book Page 141 Monday, March 14, 2011 3:01 PM

System Resource I/O Port Chassis Index

Name systemResourceIOPortchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

System Resource I/O Port Index

Name systemResourceIOPortIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.2
Description Defines the index (one-based) of the system resource I/O ports
in this chassis.
Syntax DellObjectRange
Access Read-only

System Resource I/O Port State Capabilities

Name systemResourceIOPortStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.3
Description Defines the capabilities of the system resource I/O port.
Syntax DellStateCapabilities
Access Read-only

System Resource I/O Port State Settings

Name systemResourceIOPortStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.4
Description Defines the state and allows the setting of the system resource
I/O port.
Syntax DellStateSettings
Access Read-write

System Resource Group 141


book.book Page 142 Monday, March 14, 2011 3:01 PM

System Resource I/O Port Status

Name systemResourceIOPortStatus
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.5
Description Defines the status of the system resource I/O port.
Syntax DellStateSettings
Access Read-only

System Resource I/O Port Owner Index Reference

Name systemResourceIOPortOwnerIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.6
Description Defines the index to the associated system resource owner in this
chassis.
Syntax DellObjectRange
Access Read-only

System Resource I/O Port Share Disposition

Name systemResourceIOPortShareDisposition
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.7
Description Defines the share disposition of the system resource I/O port.
Syntax DellResourceShareDisposition (See Table 8-3)
Access Read-only

System Resource I/O Port Starting Address

Name systemResourceIOPortStartingAddress
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.8
Description Defines the 64 bits of the starting address of the system resource
I/O port.
Syntax DellUnsigned64BitRange
Access Read-only

142 System Resource Group


book.book Page 143 Monday, March 14, 2011 3:01 PM

System Resource I/O Port Ending Address

Name systemResourceIOPortEndingAddress
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.9
Description Defines the 64 bits of the ending address of the system resource
I/O port.
Syntax DellUnsigned64BitRange
Access Read-only

System Resource Memory Table


Name systemResourceMemoryTable
Object ID 1.3.6.1.4.1.674.10892.1.500.40
Description Defines the System Resource Memory Table.
Syntax SEQUENCE OF SystemResourceMemoryTableEntry
Access Not accessible

System Resource Memory Table Entry

Name systemResourceMemoryTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1
Description Defines the System Resource Memory Table entry.
Syntax SystemResourceMemoryTableEntry
Access Not accessible
Index systemResourceMemorychassisIndex,
systemResourceMemoryIndex

System Resource Memory Chassis Index

Name systemResourceMemorychassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

System Resource Group 143


book.book Page 144 Monday, March 14, 2011 3:01 PM

System Resource Memory Index

Name systemResourceMemoryIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.2
Description Defines the index of system resource memory in this chassis.
Syntax DellObjectRange
Access Read-only

System Resource Memory State Capabilities

Name systemResourceMemoryStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.3
Description Defines the capabilities of this system resource memory.
Syntax DellObjectRange
Access Read-only

System Resource Memory State Settings

Name systemResourceMemoryStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.4
Description Defines the state of this system resource memory.
Syntax DellObjectRange
Access Read-write

System Resource Memory Status

Name systemResourceMemoryStatus
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.5
Description Defines the status of this system resource memory.
Syntax DellStatus
Access Read-only

144 System Resource Group


book.book Page 145 Monday, March 14, 2011 3:01 PM

System Resource Memory Owner Index Reference

Name systemResourceMemoryOwnerIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.6
Description Defines the index to the associated system resource owner in this
chassis.
Syntax DellObjectRange
Access Read-only

System Resource Memory Share Disposition

Name systemResourceMemoryShareDisposition
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.7
Description Defines the share disposition of the system resource memory.
Syntax DellResourceShareDisposition (See Table 8-3)
Access Read-only

System Resource Memory Starting Address

Name systemResourceMemoryStartingAddress
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.8
Description Defines the 64 bits of the starting address of the system resource
memory.
Syntax DellUnsigned64BitRange
Access Read-only

System Resource Memory Ending Address

Name systemResourceMemoryEndingAddress
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.9
Description Defines the 64 bits of the ending address of the system resource
memory.
Syntax DellUnsigned64BitRange
Access Read-only

System Resource Group 145


book.book Page 146 Monday, March 14, 2011 3:01 PM

System Resource Memory Flags

Name systemResourceMemoryFlags
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.10
Description Defines the permission flags for the system resource memory.
Syntax DellResourceMemoryFlags (See Table 8-4)
Access Read-only

System Resource Interrupt Table

Name systemResourceInterruptTable
Object ID 1.3.6.1.4.1.674.10892.1.500.50
Description Defines the System Resource Interrupt Table.
Syntax SEQUENCE OF SystemResourceInterruptTableEntry
Access Not accessible

System Resource Interrupt Table Entry

Name systemResourceInterruptTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.500.50.1
Description Defines the System Resource Interrupt Table entry.
Syntax SystemResourceInterruptTableEntry
Access Not accessible
Index systemResourceInterruptchassisIndex,
systemResourceInterruptIndex

System Resource Interrupt Chassis Index

Name systemResourceInterruptchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Not accessible

146 System Resource Group


book.book Page 147 Monday, March 14, 2011 3:01 PM

System Resource Interrupt Index

Name systemResourceInterruptIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.2
Description Defines the index (one-based) of this interrupt resource.
Syntax DellObjectRange
Access Read-only

System Resource Interrupt State Capabilities

Name systemResourceInterruptStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.3
Description Defines the capabilities of this system resource interrupt.
Syntax DellStateCapabilities
Access Read-only

System Resource Interrupt State Settings

Name systemResourceInterruptStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.4
Description Defines the state of this system resource interrupt.
Syntax DellStateSettings
Access Read-write

System Resource Interrupt Status

Name systemResourceInterruptStatus
Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.5
Description Defines the status of this system resource interrupt.
Syntax DellStatus
Access Read-only

System Resource Group 147


book.book Page 148 Monday, March 14, 2011 3:01 PM

System Resource Interrupt Owner Index Reference

Name systemResourceInterruptOwnerIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.6
Description Defines the index for the associated system resource owner in
this chassis.
Syntax DellObjectRange
Access Read-only

System Resource Interrupt Owner Share Disposition

Name systemResourceInterruptShareDisposition
Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.7
Description Defines the share disposition of the system resource interrupt.
Syntax DellResourceShareDisposition (See Table 8-3)
Access Read-only

System Resource Interrupt Level

Name systemResourceInterruptLevel
Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.8
Description Defines the interrupt request (IRQ) level of the system
resource interrupt.
Syntax DellUnsigned32BitRange
Access Read-only

System Resource Interrupt Type

Name systemResourceInterruptType
Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.9
Description Defines the interrupt type of the system resource interrupt.
Syntax DellResourceInterruptType (See Table 8-5)
Access Read-only

148 System Resource Group


book.book Page 149 Monday, March 14, 2011 3:01 PM

System Resource Interrupt Trigger

Name systemResourceInterruptTrigger
Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.10
Description Defines the interrupt trigger of the system resource interrupt.
Syntax DellResourceInterruptTrigger (See Table 8-6)
Access Read-only

System Resource Direct Memory Access (DMA) Table

Name systemResourceDMATable
Object ID 1.3.6.1.4.1.674.10892.1.500.60
Description Defines the System Resource DMA Table.
Syntax SEQUENCE OF SystemResourceDMATableEntry
Access Not accessible

System Resource DMA Table Entry

Name systemResourceDMATable
Object ID 1.3.6.1.4.1.674.10892.1.500.60.1
Description Defines the System Resource DMA Table entry.
Syntax SystemResourceDMATableEntry
Access Not accessible
Index systemResourceDMAchassisIndex, systemResourceDMAIndex

System Resource DMA Chassis Index

Name systemResourceDMAchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

System Resource Group 149


book.book Page 150 Monday, March 14, 2011 3:01 PM

System Resource DMA Index

Name systemResourceDMAIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.2
Description Defines the index of system resource DMAs in this chassis.
Syntax DellObjectRange
Access Read-only

System Resource DMA State Capabilities

Name systemResourceDMAStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.3
Description Defines the capabilities of this system resource DMA.
Syntax DellStateCapabilities
Access Read-only

System Resource DMA State Settings

Name systemResourceDMAStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.4
Description Defines the state and setting of this system resource DMA.
Syntax DellStateSettings
Access Read-write

System Resource DMA Status

Name systemResourceDMAStatus
Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.5
Description Defines the status of this system resource DMA.
Syntax DellStatus
Access Read-only

150 System Resource Group


book.book Page 151 Monday, March 14, 2011 3:01 PM

System Resource DMA Owner Index Reference

Name systemResourceDMAOwnerIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.6
Description Defines the index to the associated system resource owner in this
chassis.
Syntax DellObjectRange
Access Read-only

System Resource DMA Share Disposition

Name systemResourceDMAShareDisposition
Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.7
Description Defines the share disposition of the system resource DMA.
Syntax DellResourceShareDisposition (See Table 8-3)
Access Read-only

System Resource DMA Maximum Transfer Size

Name systemResourceDMAMaximumTransferSize
Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.8
Description Defines the maximum size of a memory transfer in bytes for the
system resource DMA.
Syntax DellUnsigned32BitRange
Access Read-only

System Resource DMA Transfer Width

Name systemResourceDMATransferWidth
Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.9
Description Defines the transfer width of the system resource DMA.
Syntax DellResourceDMATransferWidth (See Table 8-8)
Access Read-only

System Resource Group 151


book.book Page 152 Monday, March 14, 2011 3:01 PM

System Resource DMA Bus Master

Name systemResourceDMABusMaster
Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.10
Description Defines the bus mastering capabilities of the system resource DMA.
Syntax DellResourceDMABusMaster (See Table 8-7)
Access Read-only

System Resource Group Variable Values


This section includes definitions for server administrator-specific variable
values used in this section.

Table 8-1. System Resource Map Type

Variable Name: DellSystemResourceMapType


Data Type: Integer
Possible Data Values Meaning of Data Value
other(1) The system resource map type is not one of the
following:
unknown(2) The system resource map type is unknown
(not known or not monitored).
typeOne(3) The system resource map is type 1 (one).

Table 8-2. Resource Owner Interface Type

Variable Name: DellResourceOwnerInterfaceType


Data Type: Integer
Possible Data Values Meaning of Data Value
typeIsOther(1) The interface type is not one of the following:
typeIsUnknown(2) The interface type is unknown.
typeIsInternal(3) The interface type is internal.
typeIsISA(4) The interface type is an Industry Standard
Architecture (ISA) bus.

152 System Resource Group


book.book Page 153 Monday, March 14, 2011 3:01 PM

Table 8-2. Resource Owner Interface Type (continued)

Variable Name: DellResourceOwnerInterfaceType


Data Type: Integer
Possible Data Values Meaning of Data Value
typeIsEISA(5) The interface type is an Extended Industry Standard
Architecture (EISA) bus.
typeIsMCA(6) The interface type is a microchannel architecture
(MCA) bus.
typeIsTurboChannel(7) The interface type is a turbo-channel bus.

Table 8-3. Resource Share Disposition

Variable Name: DellResourceShareDisposition


Data Type: Integer
Possible Data Values Meaning of Data Value
shareIsOther(1) The share disposition is not one of the following:
shareIsUnknown(2) The share disposition is unknown (not known
or not monitored).
shareIsDeviceExclusive(3) The share disposition is device exclusive.
shareIsDriverExclusive(4) The share disposition is driver exclusive.
shareIsShared(5) The share disposition is shared.

Table 8-4. Resource Memory Flags

Variable Name: DellResourceMemoryFlags


Data Type: Integer
Possible Data Values Meaning of Data Value
memoryIsReadOnly(1) The resource memory is read-only.
memoryIsWriteOnly(2) The resource memory is write-only.
memoryIsPreFetchable(4) The resource memory is prefetchable.
memoryIsCombinedWritable(8) The resource memory is read-write.
memoryIsF24(16) The resource memory is F24.

System Resource Group 153


book.book Page 154 Monday, March 14, 2011 3:01 PM

Table 8-5. Resource Interrupt Type

Variable Name: DellResourceInterruptType


Data Type: Integer
Possible Data Values Meaning of Data Value
interruptIsLevelSensitive(1) The interrupt type is level sensitive.
interruptIsLatched(2) The interrupt type is latched.

Table 8-6. Resource Interrupt Trigger

Variable Name: DellResourceInterruptTrigger


Data Type: Integer
Possible Data Values Meaning of Data Value
interruptIsActiveWhenLow(1) The interrupt trigger is active on a
low signal.
interruptIsActiveWhenHigh(2) The interrupt trigger is active on a
high signal.

Table 8-7. Resource DMA Bus Master

Variable Name: DellResourceDMABusMaster


Data Type: Integer
Possible Data Values Meaning of Data Value
dmaIsOther(1) The DMA bus master capability is not one of
the following:
dmaIsUnknown(2) The DMA bus master capability is unknown.
dmaIsNotABusmaster(3) The DMA does not have bus master capability.

154 System Resource Group


book.book Page 155 Monday, March 14, 2011 3:01 PM

Table 8-8. Resource DMA Transfer Width

Variable Name: DellResourceDMATransferWidth


Data Type: Integer
Possible Data Values Meaning of Data Value
dmaTransferWidthIsOther(1) The DMA transfer width is not one of the
following:
dmaTransferWidthIsunknown(2) The DMA transfer width is unknown.
dmaTransferWidthIs8Bits(3) The DMA transfer width is 8 bits.
dmaTransferWidthIs16Bits(4) The DMA transfer width is 16 bits.
dmaTransferWidthIs32Bits(5) The DMA transfer width is 32 bits.
dmaTransferWidthIs64Bits(6) The DMA transfer width is 64 bits.
dmaTransferWidthIs128Bits(7) The DMA transfer width is 128 bits.

System Resource Group 155


book.book Page 156 Monday, March 14, 2011 3:01 PM

156 System Resource Group


book.book Page 157 Monday, March 14, 2011 3:01 PM

9
Power Group
The Power Group provides information about power units (a group of power
supplies in a system chassis), power supplies, and voltage and amperage probes.
NOTE: Power Management features are only available for PowerEdge systems
that have hot-swappable power supplies and not systems that have a fixed, non-
redundant power supply installed.

Power Group Tables


The following management information base (MIB) tables define objects for
the Power Group:
• "Power Unit Table" on page 157
• "Power Supply Table" on page 160
• "Voltage Probe Table" on page 164
• "Amperage Probe Table" on page 169
• "AC Power Switch Table" on page 175
• "AC Power Cord Table" on page 177
• "Battery Table" on page 180
• "Power Usage Table" on page 182
• "Power Profile Table" on page 188

Power Unit Table

Name powerUnitTable
Object ID 1.3.6.1.4.1.674.10892.1.600.10
Description Defines the Power Unit Table.
Syntax PowerUnitTableEntry
Access Not accessible

Power Group 157


book.book Page 158 Monday, March 14, 2011 3:01 PM

Power Unit Table Entry

Name powerUnitTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.600.10.1
Description Defines the Power Unit Table entry.
Syntax DellObjectRange
Access Read-only
Index powerUnitchassisIndex, powerUnitIndex

Power Unit Chassis Index

Name powerUnitchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Power Unit Index

Name powerUnitIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.2
Description Defines the index of the power unit in this chassis.
Syntax DellObjectRange
Access Read-only

Power Unit State Capabilities

Name powerUnitStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.3
Description Defines the capabilities of the power unit.
Syntax DellStateCapabilities
Access Read-only

158 Power Group


book.book Page 159 Monday, March 14, 2011 3:01 PM

Power Unit State Settings

Name powerUnitStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.4
Description Defines the state and settings of the power unit.
Syntax DellStateSettings
Access Read-write

Power Unit Redundancy Status

Name powerUnitRedundancyStatus
Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.5
Description Defines the redundancy status of the power unit.
Syntax DellStatusRedundancy
Access Read-only

Power Supply Count for Redundancy

Name powerSupplyCountForRedundancy
Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.6
Description Defines the total number of power supplies required for this
power unit to have redundancy.
Syntax DellString
Access Read-only

Power Unit Name

Name powerUnitName
Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.7
Description Defines the name of the power unit in this chassis.
Syntax DellString
Access Read-only

Power Group 159


book.book Page 160 Monday, March 14, 2011 3:01 PM

Power Unit Status

Name powerUnitStatus
Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.8
Description Defines the status of the power unit in this chassis.
Syntax DellStatus
Access Read-only

Power Supply Table

Name powerSupplyTable
Object ID 1.3.6.1.4.1.674.10892.1.600.12
Description Defines the Power Supply Table.
Syntax PowerSupplyTableEntry
Access Not accessible

Power Supply Table Entry

Name powerSupplyTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1
Description Defines the Power Supply Table entry.
Syntax PowerSupplyTableEntry
Access Not accessible
Index powerSupplychassisIndex, powerSupplyIndex

Power Supply Chassis Index

Name powerSupplychassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

160 Power Group


book.book Page 161 Monday, March 14, 2011 3:01 PM

Power Supply Index

Name powerSupplyIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.2
Description Defines the index of power supply.
Syntax DellObjectRange
Access Read-only

Power Supply State Capabilities Unique

Name powerSupplyStateCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.3
Description Defines the capabilities of the power supply.
Syntax DellPowerSupplyStateCapabilitiesUnique (See Table 9-1)
Access Read-only

Power Supply State Settings Unique

Name powerSupplyStateSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.4
Description Defines the state and settings of the power supply.
Syntax DellPowerSupplyStateSettingsUnique (See Table 9-2)
Access Read-write

Power Supply Status

Name powerSupplyStatus
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.5
Description Defines the status of the power supply.
Syntax DellStatus
Access Read-only

Power Group 161


book.book Page 162 Monday, March 14, 2011 3:01 PM

Power Supply Output Watts

Name powerSupplyOutputWatts
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.6
Description Defines the maximum sustained output wattage of the power
supply in tenths of watts.
Syntax DellSigned32BitRange
Access Read-only

Power Supply Type

Name powerSupplyType
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.7
Description Defines the type of power supply.
Syntax DellPowerSupplyType (See Table 9-3)
Access Read-only

Power Supply Location Name

Name powerSupplyLocationName
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.8
Description Defines the location name of the power supply.
Syntax DellString
Access Read-only

Power Supply Input Voltage

Name powerSupplyInputVoltage
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.9
Description Defines the input voltage to the power supply in volts.
Syntax DellSigned32BitRange
Access Read-only

162 Power Group


book.book Page 163 Monday, March 14, 2011 3:01 PM

Power Supply Power Unit Index Reference

Name powerSupplypowerUnitIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.10
Description Defines the index to the associated system power unit in this chassis.
Syntax DellObjectRange
Access Read-only

Power Supply Sensor State

Name powerSupplySensorState
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.11
Description Defines the state reported by the power supply sensor, and
supplements the state and settings of the power supply.
Syntax DellPowerSupplySensorState (See Table 9-4)
Access Read-only

Power Supply Configuration Error Type

Name powerSupplyConfigurationErrorType
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.12
Description Defines the type of configuration error reported by the power
supply sensor.
Syntax DellPowerSupplyConfigurationErrorType (See Table 9-5)
Access Read-only

Power Supply Power Monitor Capable

Name powerSupplyPowerMonitorCapable
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.13
Description Defines a boolean value that reports whether the power supply is
capable of monitoring power consumption.
Syntax DellBoolean
Access Read-only

Power Group 163


book.book Page 164 Monday, March 14, 2011 3:01 PM

Power Supply Rated Input Wattage

Name powerSupplyRatedInputWattage
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.14
Description Defines the rated input wattage of the power supply (in tenths
of Watts.)
Syntax DellSigned32BitRange
Access Read-only

Voltage Probe Table

Name voltageProbeTable
Object ID 1.3.6.1.4.1.674.10892.1.600.20
Description Defines the Voltage Probe Table.
Syntax VoltageProbeTableEntry
Access Not accessible

Voltage Probe Table Entry

Name voltageProbeTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1
Description Defines the Voltage Probe Table entry.
Syntax VoltageProbeTableEntry
Access Not accessible
Index voltageProbechassisIndex, voltageProbeIndex

Voltage Probe Chassis Index

Name voltageProbechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

164 Power Group


book.book Page 165 Monday, March 14, 2011 3:01 PM

Voltage Probe Index

Name voltageProbeIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.2
Description Defines the index of voltage probes in this chassis.
Syntax DellObjectRange
Access Read-only

Voltage Probe State Capabilities

Name voltageProbeStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.3
Description Defines the capabilities of the voltage probe.
Syntax DellStateCapabilities
Access Read-only

Voltage Probe State Settings

Name voltageProbeStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.4
Description Defines the state and settings of the voltage probe.
Syntax DellStateSettings
Access Read-write

Voltage Probe Status

Name voltageProbeStatus
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.5
Description Defines the status of the voltage probe.
Syntax DellStatusProbe
Access Read-only

Power Group 165


book.book Page 166 Monday, March 14, 2011 3:01 PM

Voltage Probe Reading

Name voltageProbeReading
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.6
Description Defines the value of the voltage probe reading. The value is an integer
representing the voltage in millivolts that the probe is reading.
When the value for voltageProbeType is voltageProbeTypeIsDiscrete,
a value is not returned for this attribute.
Syntax DellSigned32BitRange
Access Read-only

Voltage Probe Type

Name voltageProbeType
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.7
Description Defines the type of the voltage probe.
Syntax DellVoltageType
Access Read-only

Voltage Probe Location Name

Name voltageProbeLocationName
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.8
Description Defines the location of the voltage probe in this chassis.
Syntax DellString
Access Read-only

Voltage Probe Upper Nonrecoverable Threshold

Name voltageProbeUpperNonRecoverableThreshold
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.9
Description Defines the value of the voltage probe’s upper nonrecoverable
threshold.
Syntax DellSigned32BitRange

166 Power Group


book.book Page 167 Monday, March 14, 2011 3:01 PM

Name voltageProbeUpperNonRecoverableThreshold
Access Read-only

Voltage Probe Upper Critical Threshold

Name voltageProbeUpperCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.10
Description Defines the value of the voltage probe’s upper critical threshold.
Syntax DellSigned32BitRange
Access Read-only

Voltage Probe Upper Noncritical Threshold

Name voltageProbeUpperNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.11
Description Defines the user-assigned value of the voltage probe’s upper
noncritical threshold.
Syntax DellSigned32BitRange
Access Read-write

Voltage Probe Lower Noncritical Threshold

Name voltageProbeLowerNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.12
Description Defines the user-assigned value of the voltage probe’s lower
noncritical threshold.
Syntax DellSigned32BitRange
Access Read-write

Power Group 167


book.book Page 168 Monday, March 14, 2011 3:01 PM

Voltage Probe Lower Critical Threshold

Name voltageProbeLowerCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.13
Description Defines the value of the voltage probe’s lower critical threshold.
Syntax DellSigned32BitRange
Access Read-only

Voltage Probe Lower Nonrecoverable Threshold

Name voltageProbeLowerNonRecoverableThreshold
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.14
Description Defines the value of the voltage probe’s lower nonrecoverable
threshold.
Syntax DellSigned32BitRange
Access Read-only

Voltage Probe Probe Capabilities

Name voltageProbeProbeCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.15
Description Defines the probe capabilities of the voltage probe.
Syntax DellProbeCapabilities
Access Read-only

168 Power Group


book.book Page 169 Monday, March 14, 2011 3:01 PM

Voltage Probe Discrete Reading

Name voltageProbeDiscreteReading
Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.16
Description Defines the reading for a voltage probe of type
voltageProbeTypeIsDiscrete.
When the value for voltageProbeType is other than
voltageProbeTypeIsDiscrete, a value is not returned for this
attribute. When the value for voltageProbeType is
voltageProbeTypeIsDiscrete, the value returned for this attribute
is the discrete reading for the probe.
Syntax DellVoltageDiscreteReading
Access Read-only

Amperage Probe Table

Name amperageProbeTable
Object ID 1.3.6.1.4.1.674.10892.1.600.30
Description Defines the Amperage Probe Table.
Syntax SEQUENCE OF AmperageProbeTableEntry
Access Not accessible

Amperage Probe Table Entry

Name amperageProbeTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1
Description Defines the Amperage Probe Table entry.
Syntax AmperageProbeTableEntry
Access Not accessible
Index amperageProbechassisIndex, amperageProbeIndex

Power Group 169


book.book Page 170 Monday, March 14, 2011 3:01 PM

Amperage Probe Chassis Index

Name amperageProbechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Amperage Probe Index

Name amperageProbeIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.2
Description Defines the index of amperage probes in this chassis.
Syntax DellObjectRange
Access Read-only

Amperage Probe State Capabilities

Name amperageProbeStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.3
Description Defines the capabilities of the amperage probe.
Syntax DellStateCapabilities
Access Read-only

Amperage Probe State Settings

Name amperageProbeStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.4
Description Defines the state and settings of the amperage probe.
Syntax DellStateSettings
Access Read-write

170 Power Group


book.book Page 171 Monday, March 14, 2011 3:01 PM

Amperage Probe Status

Name amperageProbeStatus
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.5
Description Defines the status of the amperage probe.
Syntax DellSigned32BitRange
Access Read-only

Amperage Probe Reading

Name amperageProbeReading
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.6
Description Defines the reading for an amperage probe of type other than
amperageProbeTypeIsDiscrete.
When the value for amperageProbeType is
amperageProbeTypeIsPowerSupplyAmps or
amperageProbeTypeIsSystemAmps, the value returned for this
attribute is the power usage that the probe is reading in tenths
of Amperes.
When the value for amperageProbeType is
amperageProbeTypeIsPowerSupplyWatts or
amperageProbeTypeIsSystemWatts, the value returned for this
attribute is the power usage that the probe is reading in Watts.
When the value for amperageProbeType is other than
amperageProbeTypeIsDiscrete,
amperageProbeTypeIsPowerSupplyAmps,
amperageProbeTypeIsPowerSupplyWatts,
amperageProbeTypeIsSystemAmps, or
amperageProbeTypeIsSystemWatts, the value returned for this
attribute is the amperage that the probe is reading in Milliamps.
When the value for amperageProbeType is
amperageProbeTypeIsDiscrete, a value is not returned for this
attribute.
Syntax DellSigned32BitRange
Access Read-only

Power Group 171


book.book Page 172 Monday, March 14, 2011 3:01 PM

Amperage Probe Type

Name amperageProbeType
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.7
Description Defines the type of the amperage probe.
Syntax DellAmperageProbeType
Access Read-only

Amperage Probe Location Name

Name amperageProbeLocationName
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.8
Description Defines the location name of the amperage probe in this chassis.
Syntax DellString
Access Read-only

Amperage Probe Upper Nonrecoverable Threshold

Name amperageProbeUpperNonRecoverableThreshold
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.9
Description Defines the value of the amperage probe’s upper nonrecoverable
threshold. The value is an integer representing the amperage in
milliamperes that the probe is reading.
Syntax DellSigned32BitRange
Access Read-only

Amperage Probe Upper Critical Threshold

Name amperageProbeUpperCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.10
Description Defines the value of the amperage probe’s upper critical threshold.
Syntax DellSigned32BitRange
Access Read-only

172 Power Group


book.book Page 173 Monday, March 14, 2011 3:01 PM

Amperage Probe Upper Noncritical Threshold

Name amperageProbeUpperNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.11
Description Defines the user-assigned value of the amperage probe’s upper
critical threshold.
Syntax DellSigned32BitRange
Access Read-write

Amperage Probe Lower Noncritical Threshold

Name amperageProbeLowerNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.12
Description Defines the user-assigned value of the amperage probe’s lower
noncritical threshold.
Syntax DellSigned32BitRange
Access Read-write

Amperage Probe Lower Critical Threshold

Name amperageProbeLowerCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.13
Description Defines the value of the amperage probe’s lower
critical threshold.
Syntax DellSigned32BitRange
Access Read-only

Power Group 173


book.book Page 174 Monday, March 14, 2011 3:01 PM

Amperage Probe Lower Nonrecoverable Threshold

Name amperageProbeLowerNonRecoverableThreshold
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.14
Description Defines the value of the amperage probe’s lower
nonrecoverable threshold.
Syntax DellSigned32BitRange
Access Read-only

Amperage Probe Probe Capabilities

Name amperageProbeProbeCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.15
Description Defines the probe capabilities of the amperage probe.
Syntax DellProbeCapabilities
Access Read-only

Amperage Probe Discrete Reading

Name amperageProbeDiscreteReading
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.16
Description Defines the reading for a amperage probe of type
amperageProbeTypeIsDiscrete.
When the value for amperageProbeType is other than
amperageProbeTypeIsDiscrete, a value is not returned for this
attribute. When the value for amperageProbeType is
amperageProbeTypeIsDiscrete, the value returned for this
attribute is the discrete reading for the probe.
Syntax DellAmperageDiscreteReading (See Table 9-9)
Access Read-only

174 Power Group


book.book Page 175 Monday, March 14, 2011 3:01 PM

AC Power Switch Table

Name aCPowerSwitchTable
Object ID 1.3.6.1.4.1.674.10892.1.600.40
Description Defines the AC Power Switch Table.
Syntax SEQUENCE OF ACPowerSwitchTableEntry
Access Not accessible

AC Power Switch Table Entry

Name aCPowerSwitchTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.600.40.1
Description Defines the AC Power Switch Table entry.
Syntax ACPowerSwitchTableEntry
Access Not accessible
Index aCPowerSwitchchassisIndex, aCPowerSwitchIndex

AC Power Switch Chassis Index

Name aCPowerSwitchChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.1
Description Defines the index (one-based) of the chassis containing this
AC power switch.
Syntax DellObjectRange
Access Read-only

AC Power Switch Index

Name aCPowerSwitchIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.2
Description Defines the index (one-based) of this AC power switch.
Syntax DellObjectRange
Access Read-only

Power Group 175


book.book Page 176 Monday, March 14, 2011 3:01 PM

AC Power Switch Capabilities

Name aCPowerSwitchCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.3
Description Defines the capabilities of this AC power switch.
Syntax DellACPowerSwitchCapabilities
Access Read-only

AC Power Switch Settings

Name aCPowerSwitchSettings
Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.4
Description Defines the settings of this AC power switch.
Syntax DellACPowerSwitchSettings
Access Read-write

AC Power Switch Redundancy Status

Name aCPowerSwitchRedundancyStatus
Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.5
Description Defines the redundancy status of this AC power switch.
Syntax DellStatusRedundancy
Access Read-only

AC Power Cord Count for Redundancy

Name aCPowerCordCountForRedundancy
Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.6
Description Defines the total number of AC power cords required for this
AC power switch to have redundancy.
Syntax DellObjectRange
Access Read-only

176 Power Group


book.book Page 177 Monday, March 14, 2011 3:01 PM

AC Power Switch Name

Name aCPowerSwitchName
Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.7
Description Defines the name of this AC power switch.
Syntax DellString
Access Read-only

AC Power Switch Redundancy Mode

Name aCPowerSwitchRedundancyMode
Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.8
Description Defines the redundancy mode of this AC power switch.
Syntax DellACPowerSwitchRedundancyMode
Access Read-write

AC Power Switch Status

Name aCPowerSwitchStatus
Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.9
Description Defines the status of this AC power switch.
Syntax DellStatus
Access Read-only

AC Power Cord Table

Name aCPowerCordTable
Object ID 1.3.6.1.4.1.674.10892.1.600.42
Description Defines the AC Power Cord Table.
Syntax SEQUENCE OF ACPowerCordTableEntry
Access Not accessible

Power Group 177


book.book Page 178 Monday, March 14, 2011 3:01 PM

AC Power Cord Table Entry

Name aCPowerCordTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.600.42.1
Description Defines the AC Power Cord Table entry.
Syntax ACPowerCordTableEntry
Access Not accessible
Index aCPowerCordchassisIndex, aCPowerCordIndex

AC Power Cord Chassis Index

Name aCPowerCordChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.1
Description Defines the index (one-based) of the chassis containing this
AC power cord.
Syntax DellObjectRange
Access Read-only

AC Power Cord Index

Name aCPowerCordIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.2
Description Defines the index (one-based) of this AC power cord.
Syntax DellObjectRange
Access Read-only

AC Power Cord State Capabilities

Name aCPowerCordStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.3
Description Defines the capabilities of this AC power cord.
Syntax DellACPowerCordStateCapabilities
Access Read-only

178 Power Group


book.book Page 179 Monday, March 14, 2011 3:01 PM

AC Power Cord State Settings

Name aCPowerCordStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.4
Description Defines the settings of this AC power cord.
Syntax DellACPowerCordStateSettings
Access Read-write

AC Power Cord Status

Name aCPowerCordStatus
Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.5
Description Defines the status of this AC power cord.
Syntax DellStatus
Access Read-only

AC Power Cord AC Power Switch Index Reference

Name aCPowerCordaCPowerSwitchIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.6
Description Defines the index (one-based) to the associated AC power switch
for this AC power cord.
Syntax DellObjectRange
Access Read-only

AC Power Cord Location Name

Name aCPowerCordLocationName
Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.7
Description Defines the location name of this AC power cord.
Syntax DellString
Access Read-only

Power Group 179


book.book Page 180 Monday, March 14, 2011 3:01 PM

Battery Table

Name batteryTable
Object ID 1.3.6.1.4.1.674.10892.1.600.50
Description Defines the Battery Table.
Syntax SEQUENCE OF BatteryTableEntry
Access Not accessible

Battery Table Entry

Name batteryTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.600.50.1
Description Defines the Battery Table Entry.
Syntax BatteryTableEntry
Access Not accessible
Index batteryChassisIndex, batteryIndex

Battery Chassis Index

Name batteryChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.1
Description Defines the index (one-based) of the chassis that contains the
battery.
Syntax DellObjectRange
Access Read-only

Battery Index

Name batteryIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.2
Description Defines the index (one-based) of the battery.
Syntax DellObjectRange
Access Read-only

180 Power Group


book.book Page 181 Monday, March 14, 2011 3:01 PM

Battery State Capabilities

Name batteryStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.3
Description Defines the state capabilities of the battery.
Syntax DellStateCapabilities
Access Read-only

Battery State Settings

Name batteryStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.4
Description Defines the state settings of the battery.
Syntax DellStateSettings
Access Read-write

Battery Status

Name batteryStatus
Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.5
Description Defines the status of the battery.
Syntax DellStatus
Access Read-only

Battery Reading

Name batteryReading
Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.6
Description Defines the reading of the battery.
Syntax DellBatteryReading (see Table 9-15)
Access Read-only

Power Group 181


book.book Page 182 Monday, March 14, 2011 3:01 PM

Battery Location Name

Name batteryLocationName
Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.7
Description Defines the location of the battery.
Syntax DellString
Access Read-only

Power Usage Table

Name powerUsageTable
Object ID 1.3.6.1.4.1.674.10892.1.600.60
Description Defines the Power Usage Table.
Syntax SEQUENCE OF PowerUsageTableEntry
Access Not accessible

Power Usage Table Entry

Name powerUsageTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1
Description Defines the Power Usage Table Entry.
Syntax PowerUsageTableEntry
Access Not accessible
Index powerUsageChassisIndex, powerUsageIndex

Power Usage Chassis Index

Name powerUsageChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellObjectRange
Access Read-only

182 Power Group


book.book Page 183 Monday, March 14, 2011 3:01 PM

Power Usage Index

Name powerUsageIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.2
Description Defines the index (one-based) of the power usage information.
Syntax DellObjectRange
Access Read-only

Power Usage State Capabilities

Name powerUsageStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.3
Description Defines the state capabilities of the power usage information.
Syntax DellStateCapabilities
Access Read-only

Power Usage State Settings

Name powerUsageStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.4
Description Defines the state settings of the power usage information.
Syntax DellStateSettings
Access Read-write

Power Usage Status

Name powerUsageStatus
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.5
Description Defines the status of the power usage information.
Syntax DellStatus
Access Read-only

Power Group 183


book.book Page 184 Monday, March 14, 2011 3:01 PM

Power Usage Entity Name

Name powerUsageEntityName
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.6
Description Defines the name of the entity associated with this power usage
information.
Syntax DellString
Access Read-only

Power Usage Cumulative Wattage

Name powerUsageCumulativeWattage
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.7
Description Defines the total wattage used (in Watt-hours) by this entity
since the date and time specified by the
powerUsageCumulativeWattageStartDateName attribute.
Syntax DellUnsigned32BitRange
Access Read-only

Power Usage Cumulative Wattage Start Date Name

Name powerUsageCumulativeWattageStartDateName
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.8
Description Defines the date and time at which the data collection started
for the value reported by the powerUsageCumulativeWattage
attribute.
Syntax DellDateName
Access Read-only

Power Usage Peak Watts

Name powerUsagePeakWatts
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.9

184 Power Group


book.book Page 185 Monday, March 14, 2011 3:01 PM

Name powerUsagePeakWatts
Description Defines the peak wattage reading (in Watts) for this entity
since the date and time specified by the
powerUsagePeakWattsStartDateName attribute.
Syntax DellUnsigned32BitRange
Access Read-only

Power Usage Peak Watts Start Date Name

Name powerUsagePeakWattsStartDateName
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.10
Description Defines the date and time at which the data collection started
for the value reported by the powerUsagePeakWatts attribute.
Syntax DellDateName
Access Read-only

Power Usage Peak Watts Reading Date Name

Name powerUsagePeakWattsReadingDateName
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.11
Description Defines the date and time at which the value reported by the
powerUsagePeakWatts attribute was measured.
Syntax DellDateName
Access Read-only

Power Usage Peak Amps

Name powerUsagePeakAmps
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.12
Description Defines the peak amperage reading (in tenths of Amps) for this
entity since the date and time specified by the
powerUsagePeakAmpsStartDateName attribute.
Syntax DellUnsigned32BitRange
Access Read-only

Power Group 185


book.book Page 186 Monday, March 14, 2011 3:01 PM

Power Usage Peak Amps Start Date Name

Name powerUsagePeakAmpsStartDateName
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.13
Description Defines the date and time at which the data collection started
for the value reported by the powerUsagePeakAmps attribute.
Syntax DellDateName
Access Read-only

Power Usage Peak Amps Reading Date Name

Name powerUsagePeakAmpsReadingDateName
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.14
Description Defines the date and time at which the value reported by the
powerUsagePeakAmps attribute was measured.
Syntax DellDateName
Access Read-only

Power Usage Idle Power

Name powerUsageIdlePower
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.15
Description Defines the system idle power (in Watts). This is the minimum
power the system can consume based on the current hardware
configuration.
Syntax DellUnsigned32BitRange
Access Read-only

Power Usage Max Potential Power

Name powerUsageMaxPotentialPower
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.16

186 Power Group


book.book Page 187 Monday, March 14, 2011 3:01 PM

Name powerUsageMaxPotentialPower
Description Defines the maximum potential power (in Watts) of the system.
This is the maximum power the system can consume based on
the current hardware configuration.
Syntax DellUnsigned32BitRange
Access Read-only

Power Usage Power Cap Capabilities

Name powerUsagePowerCapCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.17
Description Defines the system power cap capabilities.
Syntax DellPowerCapCapabilities
Access Read-only

Power Usage Power Cap Setting

Name powerUsagePowerCapSetting
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.18
Description Defines the system power cap setting.
Syntax DellPowerCapSetting
Access Read-only

Power Usage Power Cap Value

Name powerUsagePowerCapValue
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.19
Description Defines the system power cap value (in Watts).
Syntax DellUnsigned32BitRange
Access Read-only

Power Group 187


book.book Page 188 Monday, March 14, 2011 3:01 PM

Power Usage Instantaneous Headroom

Name powerUsageInstantaneousHeadroom
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.20
Description Defines the system instantaneous headroom (in Watts). This is
the theoretical maximum power drawn by the power supply
minus instantaneous power draw.
Syntax DellUnsigned32BitRange
Access Read-only

Power Usage Peak Headroom

Name powerUsagePeakHeadroom
Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.21
Description Defines the system peak headroom (in Watts). This is the
theoretical maximum power drawn by the power supply minus
peak power draw.
Syntax DellUnsigned32BitRange
Access Read-only

Power Profile Table

Name powerProfileTable
Object ID 1.3.6.1.4.1.674.10892.1.600.70
Description Defines the Power Profile Table.
Syntax SEQUENCE OF PowerProfileTableEntry
Access Not accessible

Power Profile Table Entry

Name powerProfileTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.600.70.1
Description Defines the Power Profile Table Entry.
Syntax PowerProfileTableEntry

188 Power Group


book.book Page 189 Monday, March 14, 2011 3:01 PM

Name powerProfileTableEntry
Access Not accessible
Index powerProfileChassisIndex, powerProfileIndex

Power Profile Chassis Index

Name powerProfileChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellObjectRange
Access Read-only

Power Profile Index

Name powerProfileIndex
Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.2
Description Defines the index (one-based) of the power profile information.
Syntax DellObjectRange
Access Read-only

Power Profile Supported Profiles

Name powerProfileSupportedProfiles
Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.3
Description Defines the supported power profiles.
Syntax DellPowerProfileType
Access Read-only

Power Profile Setting

Name powerProfileSetting
Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.4
Description Defines the power profile setting.

Power Group 189


book.book Page 190 Monday, March 14, 2011 3:01 PM

Name powerProfileSetting
Syntax DellPowerProfileType
Access Read-only

Power Profile Custom CPU Management Capabilities

Name powerProfileCustomCPUManagementCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.5
Description Defines the custom CPU power and performance management
capabilities that are available for the Custom power profile.
Syntax DellCPUPowerPerformanceManagementType
Access Read-only

Power Profile Custom CPU Management Setting

Name powerProfileCustomCPUManagementSetting
Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.6
Description Defines the custom CPU power and performance management
setting for the Custom power profile.
Syntax DellCPUPowerPerformanceManagementType
Access Read-only

Power Profile Custom Memory Management Capabilities

Name powerProfileCustomMemoryManagementCapabiliti
es
Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.7
Description Defines the custom memory power and performance
management capabilities that are available for the Custom
power profile.
Syntax DellMemoryPowerPerformanceManagementType
Access Read-only

190 Power Group


book.book Page 191 Monday, March 14, 2011 3:01 PM

Power Profile Custom Memory Management Setting

Name powerProfileCustomMemoryManagementSetting
Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.8
Description Defines the custom memory power and performance
management setting for the Custom power profile.
Syntax DellMemoryPowerPerformanceManagementType
Access Read-only

Power Profile Custom Fan Management Capabilities

Name powerProfileCustomFanManagementCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.9
Description Defines the custom fan power and performance management
capabilities that are available for the Custom power profile.
Syntax DellFanPowerPerformanceManagementType
Access Read-only

Power Profile Custom Fan Management Setting

Name powerProfileCustomFanManagementSetting
Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.10
Description Defines the custom fan power and performance management
setting for the Custom power profile.
Syntax DellFanPowerPerformanceManagementType
Access Read-only

Power Group Variable Values


This section includes definitions for server administrator-specific variable
values used in this section.

Power Group 191


book.book Page 192 Monday, March 14, 2011 3:01 PM

Table 9-1. Power Supply State Capabilities Unique

Variable Name: DellPowerSupplyStateCapabilitiesUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The power supply’s capabilities are unknown.
onlineCapable(2) The power supply can be disabled (offline, a binary
0 value) or enabled (online, a binary 1 value).
notReadyCapable(4) The power supply’s capabilities are not ready.

Table 9-2. Power Supply State Settings Unique

Variable Name: DellPowerSupplyStateSettingsUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The power supply’s capabilities are unknown.
onLine(2) The power supply’s state is disabled (offline, a
binary 0 value) or enabled (online, a binary 1 value).
notReady(4) The power supply’s state is not ready.
fanFailure(8) The power supply fan has failed.
onlineAndFanFailure(10) The power supply is online and indicating that its
fan is not working.
powerSupplyIsON(16) The power supply is indicating that it is on.
powerSupplyIsOk(32) The power supply is indicating that it is OK.
acSwitchIsON(64) The power supply is indicating that the AC power
switch is on.
onlineandAcSwitchIsON The power supply is online and indicating that the
(66) AC power supply switch capability is activated.
acPowerIsON(128) The power supply is indicating that the AC power
is on.
onlineAndAcPowerIsON The power supply is online and indicating that the
(130) AC power is on.

192 Power Group


book.book Page 193 Monday, March 14, 2011 3:01 PM

Table 9-2. Power Supply State Settings Unique (continued)

Variable Name: DellPowerSupplyStateSettingsUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
onlineAndPredictiveFail The power supply is online and indicating that it
ure(210) has a problem.
acPowerAndSwitchAreOn The power supply is online and OK.
PowerSupplyIsOnIsOkAnd
Online(242)

Table 9-3. Power Supply Type Definitions

Variable Name: DellPowerSupplyType


Data Type: Integer
Possible Data Values Meaning of Data Value
powerSupplyTypeIsOther(1) The power supply type is not one of
the following:
powerSupplyTypeIsUnknown(2) The power supply type is unknown
(not known or not monitored).
powerSupplyTypeIsLinear(3) The power supply type is a linear
power supply.
powerSupplyTypeIsSwitching(4) The power supply type is a switching
power supply.
powerSupplyTypeIsBattery(5) The power supply type is a battery.
powerSupplyTypeIsUPS(6) The power supply type is an
uninterruptable power supply.
powerSupplyTypeIsConverter(7) The power supply type is a power
converter power supply.
powerSupplyTypeIsRegulator(8) The power supply type is a regulator
power supply.
powerSupplyTypeIsAC(9) The power supply type is an AC power
supply.

Power Group 193


book.book Page 194 Monday, March 14, 2011 3:01 PM

Table 9-3. Power Supply Type Definitions (continued)

Variable Name: DellPowerSupplyType


Data Type: Integer
Possible Data Values Meaning of Data Value
powerSupplyTypeIsDC(10) The power supply type is a DC power
supply.
powerSupplyTypeIsVRM(11) The power supply type is a voltage
regulator module (VRM) power
supply.

Table 9-4. Power Supply Sensor State

Variable Name: DellPowerSupplySensorState


Data Type: Integer
Possible Data Values Meaning of Data Value
presenceDetected(1) The power supply’s presence is detected.
psFailureDetected(2) The power supply failure is detected.
predictiveFailure(4) The power supply sensor detects predictive
failure
psACLost(8) The power supply’s AC power is lost.
acLostOrOutOfRange(16) The power supply’s AC power is lost or out
of range.
acOutOfRangeButPresent(32) The power supply’s AC power is present, but
it is out of range.
configurationError(64) The power supply sensor detects a
configuration error.

194 Power Group


book.book Page 195 Monday, March 14, 2011 3:01 PM

Table 9-5. Power Supply Configuration Error Type

Variable Name: DellPowerSupplyConfigurationErrorType


Data Type: Integer
Possible Data Values Meaning of Data Value
vendorMismatch(1) The power supply configuration error type is
vendor mismatch.
revisionMismatch(2) The power supply configuration error type is
revision mismatch.
processorMissing(3) The power supply configuration error type is
processor missing.

Table 9-6. Voltage Probe Type

Variable Name: DellVoltageType


Data Type: Integer
Possible Data Values Meaning of Data Value
voltageProbeTypeIsOther(1) The voltage probe type is not one of the
following:
voltageProbeTypeIsUnknown(2) The voltage probe type is unknown
(not known or not monitored).
voltageProbeTypeIs1Point5Volt The voltage probe type is a 1.5-volt (V)
(3) probe.
voltageProbeTypeIs3Point3Volt The voltage probe type is a 3.3-V probe.
(4)
voltageProbeTypeIs5Volt(5) The voltage probe type is a 5-V probe.
voltageProbeTypeIsMinus5Volt The voltage probe type is a –5-V probe.
(6)
voltageProbeTypeIs12Volt(7) The voltage probe type is a 12-V probe.
voltageProbeTypeIsMinus12Volt The voltage probe type is a –12-V probe.
(8)
voltageProbeTypeIsIO(9) The voltage probe type is an I/O volt
probe.

Power Group 195


book.book Page 196 Monday, March 14, 2011 3:01 PM

Table 9-6. Voltage Probe Type (continued)

Variable Name: DellVoltageType


Data Type: Integer
Possible Data Values Meaning of Data Value
voltageProbeTypeIsCore(10) The voltage probe type is a core volt
probe.
voltageProbeTypeIsFLEA(11) The voltage probe type is a FLEA
(standby) volt probe.
voltageProbeTypeIsBattery(12) The voltage probe type is a battery volt
probe.
voltageProbeTypeIsTerminator The voltage probe type is a SCSI
(13) termination volt probe.
voltageProbeTypeIs2Point5Volt The voltage probe type is a 2.5-V probe.
(14)
voltageProbeTypeIsGTL(15) The voltage probe type is a ground
termination logic (GTL) probe.
voltageProbeTypeIsDiscrete(16) The voltage probe type is a voltage probe
with discrete reading.

Table 9-7. Voltage Probe Discrete Reading

Variable Name: DellVoltageDiscreteReading


Data Type: Integer
Possible Data Values Meaning of Data Value
voltageIsGood(1) The voltage probe discrete reading is good.
voltageIsBad(2) The voltage probe discrete reading is bad.

196 Power Group


book.book Page 197 Monday, March 14, 2011 3:01 PM

Table 9-8. Amperage Probe Definitions

Variable Name: DellAmperageType


Data Type: Integer
Possible Data Values Meaning of Data Value
amperageProbeTypeIsOther(1) The amperage probe type is
not one of the following:
amperageProbeTypeIsUnknown(2) The amperage probe type is
unknown (not known or
not monitored).
amperageProbeTypeIs1Point5Volt(3) The amperage probe type is a
1.5-ampere (A) probe.
amperageProbeTypeIs3Point3volt(4) The amperage probe type is a
3.3-A probe.
amperageProbeTypeIs5Volt(5) The amperage probe type is a
5-A probe.
amperageProbeTypeIsMinus5Volt(6) The amperage probe type is a
–5-A probe.
amperageProbeTypeIs12Volt(7) The amperage probe type is a
12-A probe.
amperageProbeTypeIsMinus12Volt(8) The amperage probe type is a
–12-A probe.
amperageProbeTypeIsIO(9) The amperage probe type is an
I/O amperage probe.
amperageProbeTypeIsCore(10) The amperage probe type is a
core amperage probe.
amperageProbeTypeIsFLEA(11) The amperage probe type is a
FLEA (standby) amperage
probe.
amperageProbeTypeIsBattery(12) The amperage probe type is a
battery amperage probe.
amperageProbeTypeIsTerminator(13) The amperage probe type is a
Small Computer System
Interface (SCSI) termination
amperage probe.

Power Group 197


book.book Page 198 Monday, March 14, 2011 3:01 PM

Table 9-8. Amperage Probe Definitions (continued)

Variable Name: DellAmperageType


Data Type: Integer
Possible Data Values Meaning of Data Value
amperageProbeTypeIs2Point5Volt(14) The amperage probe type is a
2.5-V amperage probe.
amperageProbeTypeIsGTL(15) The amperage probe type is a
Gunning Transceiver Logic
(GTL) probe.
amperageProbeTypeIsDiscrete(16) The amperage probe type is an
amperage probe with
discrete reading.
amperageProbeTypeIsPowerSupplyAmps(23) The amperage probe type is
power supply probe with
reading in Amperes.
amperageProbeTypeIsPowerSupplyWatts The amperage probe type is
(24) power supply probe with
reading in Watts.
amperageProbeTypeIsSystemAmps(25) The amperage probe type is
system probe with reading in
Amperes.
amperageProbeTypeIsSystemWatts(26) The amperage probe type is
system probe with reading in
Watts.

Table 9-9. Amperage Probe Discrete Reading

Variable Name: DellAmperageDiscreteReading


Data Type: Integer
Possible Data Values Meaning of Data Value
amperageIsGood(1) The amperage probe discrete reading is good.
amperageIsBad(2) The amperage probe discrete reading is bad.

198 Power Group


book.book Page 199 Monday, March 14, 2011 3:01 PM

Table 9-10. AC Power Switch Capabilities

Variable Name: DellACPowerSwitchCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
unknownCapabilities(1) The AC power switch’s capabilities
are unknown.
inputSourceCord1NoReturnCapable(2) Input source is AC power cord 1,
with no return.
inputSourceCord1ReturnCapable(4) Input source is AC power cord 1,
with return.
inputSourceCord2NoReturnCapable(8) Input source is AC power cord 2,
with no return.
inputSourceCord2ReturnCapable(16) Input source is AC power cord 2,
with return.
inputSourceSharedCapable(32) Input source is shared.

Table 9-11. AC Power Switch Settings

Variable Name: DellACPowerSwitchSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The AC power switch’s settings are unknown.
inputSourceCord1NoReturn(2) Input source is AC power cord 1, with no return.
inputSourceCord1Return(4) Input source is AC power cord 1, with return.
inputSourceCord2NoReturn(8) Input source is AC power cord 2, with no return.
inputSourceCord2Return(16) Input source is AC power cord 2, with return.
inputSourceShared(32) Input source is shared.

Power Group 199


book.book Page 200 Monday, March 14, 2011 3:01 PM

Table 9-12. AC Power Switch Redundancy Mode

Variable Name: DellACPowerSwitchRedundancyMode


Data Type: Integer
Possible Data Values Meaning of Data Value
nonRedundant(1) The AC power switch is not expecting redundancy.
redundant(2) The AC power switch is expecting redundancy.

Table 9-13. AC Power Cord State Capabilities

Variable Name: DellACPowerCordStateCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The AC power cord’s capabilities are unknown.
onlineCapable(2) The AC power cord can be disabled (offline) or
enabled (online).
notReadyCapable(4) The AC power cord’s capabilities are not ready.

Table 9-14. AC Power Cord State Settings

Variable Name: DellACPowerCordStateSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The AC power cord’s state is unknown.
online(2) The AC power cord’s state is disabled (offline) 0 or
enabled (online) 1.
notReady(4) The AC power cord’s state is not ready.
acPowerCordHasPower The AC power cord has power.
(8)
acPowerCordIsActive The AC power cord is the active source of
Source(16) AC power.

200 Power Group


book.book Page 201 Monday, March 14, 2011 3:01 PM

Table 9-15. Battery Reading

Variable Name: DellBatteryReading


Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
predictiveFailure(1) Battery sensor detects predictive failure.
failed(2) Battery has failed.
presenceDetected(4) Battery presence is detected.

Table 9-16. Power Cap Capabilities

Variable Name: DellPowerCapCapabilities


Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
none(0) No power cap capabilities are available.
enable(1) Power cap can be enabled.
disable(2) Power cap can be disabled.

Table 9-17. Power Cap Setting

Variable Name: DellPowerCapSetting


Data Type: Integer
Possible Data Values Meaning of Data Value
disabled(0) Power cap is disabled.
enabled(1) Power cap is enabled.

Power Group 201


book.book Page 202 Monday, March 14, 2011 3:01 PM

Table 9-18. Power Profile Type

Variable Name: DellPowerProfileType


Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
maxPerformance(1) Power profile type is Maximum Performance.
osControl(2) Power profile type is OS control.
activePowerController(4) Power profile type is Active Power Controller.
custom(8) Power profile type is Custom.

Table 9-19. CPU Power Performance Management Type

Variable Name: DellCPUPowerPerformanceManagementType


Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
maxPerformance(1) CPU power and performance management type is
Maximum Performance.
minPower(2) CPU power and performance management type is
Minimum Power.
osDBPM(4) CPU power and performance management type is
OS Demand Based Power Management.
systemDBPM(8) CPU power and performance management type is
System Demand Based Power Management.

202 Power Group


book.book Page 203 Monday, March 14, 2011 3:01 PM

Table 9-20. Memory Power Performance Management Type

Variable Name: DellMemoryPowerPerformanceManagementType


Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
maxPerformance(1) Memory power and performance management
type is Maximum Performance.
mhz1333(2) Memory power and performance is 1333 MHz.
mhz1067(4) Memory power and performance is 1067 MHz.
mhz800(8) Memory power and performance is 800 MHz.
minPower(16) Memory power and performance management
type is Minimum Power.

Table 9-21. Fan Power Performance Management Type

Variable Name: DellFanPowerPerformanceManagementType


Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
maxPerformance(1) Fan power and performance management type is
Maximum Performance.
minPower(2) Fan power and performance management type is
Minimum Power.

Power Group 203


book.book Page 204 Monday, March 14, 2011 3:01 PM

204 Power Group


book.book Page 205 Monday, March 14, 2011 3:01 PM

10
Thermal Group
The Thermal Group provides information about cooling units, cooling
devices, and temperature probes. Cooling units are sets of fans or other
cooling devices in a system chassis. Thermal Group variables include
threshold values and types of cooling devices and temperature probes.

Thermal Group Tables


The following management information base (MIB) tables define the objects
in the Thermal Group:
• "Cooling Unit Table" on page 205
• "Cooling Unit Status" on page 207
• "Temperature Probe Table" on page 213

Cooling Unit Table

Name coolingUnitTable
Object ID 1.3.6.1.4.1.674.10892.1.700.10
Description Defines the Cooling Unit Table.
Syntax TableEntry
Access Not accessible

Cooling Unit Table Entry

Name coolingUnitTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.700.10.1
Description Defines the Cooling Unit Table entry.
Syntax TableEntry
Access Not accessible
Index coolingUnitchassisIndex, coolingUnitIndex

Thermal Group 205


book.book Page 206 Monday, March 14, 2011 3:01 PM

Cooling Unit Chassis Index

Name coolingUnitchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax TableEntry
Access Read-only

Cooling Unit Index

Name coolingUnitIndex
Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.2
Description Defines the index (one-based) of cooling units.
Syntax DellObjectRange
Access Read-only

Cooling Unit State Capabilities

Name coolingUnitStateCapabilties
Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.3
Description Defines the capabilities of the cooling unit.
Syntax DellStateCapabilities
Access Read-only

Cooling Unit State Settings

Name coolingUnitStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.4
Description Defines the state and settings of the cooling unit.
Syntax DellStateSettings
Access Read-write

206 Thermal Group


book.book Page 207 Monday, March 14, 2011 3:01 PM

Cooling Unit Redundancy Status

Name coolingUnitRedundancyStatus
Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.5
Description Defines the redundancy status of the cooling unit.
Syntax DellStatusRedundancy
Access Read-only

Cooling Device Count For Redundancy

Name coolingDeviceCountForRedundancy
Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.6
Description Defines the total number of cooling devices required for this
cooling unit to have redundancy.
Syntax DellObjectRange
Access Read-only

Cooling Unit Name

Name coolingUnitName
Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.7
Description Defines the cooling unit name in this chassis.
Syntax DellString
Access Read-only

Cooling Unit Status

Name coolingUnitStatus
Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.8
Description Defines the status of the cooling unit in this chassis.
Syntax DellStatus
Access Read-only

Thermal Group 207


book.book Page 208 Monday, March 14, 2011 3:01 PM

Cooling Device Table

Name coolingDeviceTable
Object ID 1.3.6.1.4.1.674.10892.1.700.12
Description Defines the Cooling Device Table.
Syntax CoolingDeviceTableEntry
Access Not accessible

Cooling Device Table Entry

Name coolingDeviceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1
Description Defines the Cooling Device Table entry.
Syntax CoolingDeviceTableEntry
Access Not accessible
Index cooling DevicechassisIndex, coolingDeviceIndex

Cooling Device Chassis Index

Name coolingDevicechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Cooling Device Index

Name coolingDeviceIndex
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.2
Description Defines the index of cooling devices in this chassis.
Syntax DellObjectRange
Access Read-only

208 Thermal Group


book.book Page 209 Monday, March 14, 2011 3:01 PM

Cooling Device State Capabilities

Name coolingDeviceStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.3
Description Defines the capabilities of the cooling device.
Syntax DellStateCapabilities
Access Read-only

Cooling Device State Settings

Name coolingDeviceStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.4
Description Defines the state and settings of the cooling device.
Syntax DellStateSettings
Access Read-write

Cooling Device Status

Name coolingDeviceStatus
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.5
Description Defines the status of the cooling device.
Syntax DellStatusProbe
Access Read-only

Thermal Group 209


book.book Page 210 Monday, March 14, 2011 3:01 PM

Cooling Device Reading

Name coolingDeviceReading
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.6
Description Defines either the cooling device’s speed in revolutions
per minute (RPM), or the off/on value of the fan.
When the value for coolingDeviceSubType is other than
coolingDeviceSubTypeIsDiscrete, the value returned for this
attribute is the speed in RPM or the OFF/ON value of the cooling
device. When the value for coolingDeviceSubType is
coolingDeviceSubTypeIsDiscrete, a value is not returned for
this attribute.
Syntax DellSigned32BitRange
Access Read-only

Cooling Device Type

Name coolingDeviceType
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.7
Description Defines the cooling device type.
Syntax DellCoolingDeviceType (See Table 10-1)
Access Read-only

Cooling Device Location Name

Name coolingDeviceLocationName
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.8
Description Defines the location of the cooling device in this chassis.
Syntax DellString
Access Read-only

210 Thermal Group


book.book Page 211 Monday, March 14, 2011 3:01 PM

Cooling Device Upper Nonrecoverable Threshold

Name coolingDeviceUppernonrecoverableThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.9
Description Defines the value of the fan’s upper nonrecoverable threshold.
Syntax DellSigned32BitRange
Access Read-only

Cooling Device Upper Critical Threshold

Name coolingDeviceUpperCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.10
Description Defines the value of the fan’s upper critical threshold.
Syntax DellSigned32BitRange
Access Read-only

Cooling Device Upper Noncritical Threshold

Name coolingDeviceUpperNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.11
Description Defines the user-assigned value of the fan’s upper noncritical
threshold.
Syntax DellSigned32BitRange
Access Read-write

Cooling Device Lower Noncritical Threshold

Name coolingDeviceLowerNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.12
Description Defines the user-assigned value of the fan’s lower noncritical
threshold.
Syntax DellSigned32BitRange
Access Read-write

Thermal Group 211


book.book Page 212 Monday, March 14, 2011 3:01 PM

Cooling Device Lower Critical Threshold

Name coolingDeviceLowerCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.13
Description Defines the value of the fan’s lower critical threshold.
Syntax DellSigned32BitRange
Access Read-only

Cooling Device Lower Nonrecoverable Threshold

Name coolingDeviceLowerNonRecoverableThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.14
Description Defines the value of the fan’s lower nonrecoverable threshold.
Syntax DellSigned32BitRange
Access Read-only

Cooling Device Cooling Unit Index Reference

Name coolingDevicecoolingUnitIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.15
Description Defines the index for the associated system cooling unit in this
chassis.
Syntax DellObjectRange
Access Read-only

Cooling Device Subtype

Name coolingDeviceSubType
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.16
Description Defines the cooling device subtype.
Syntax DellCoolingDeviceSubType (See Table 10-2)
Access Read-only

212 Thermal Group


book.book Page 213 Monday, March 14, 2011 3:01 PM

Cooling Device Probe Capabilities

Name coolingDeviceProbeCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.17
Description Defines the probe capabilities of the cooling device.
Syntax DellProbeCapabilities
Access Read-only

Cooling Device Discrete Reading

Name coolingDeviceDiscreteReading
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.18
Description Defines the reading for a voltage probe of type
coolingDeviceSubTypeIsDiscrete.
When the value for coolingDeviceSubType is other than
coolingDeviceSubTypeIsDiscrete, a value is not returned for this
attribute. When the value for coolingDeviceSubType is
coolingDeviceSubTypeIsDiscrete, the value returned for this
attribute is the discrete reading for the cooling device.
Syntax DellCoolingDeviceDiscreteReading (See Table 10-3)
Access Read-only

Temperature Probe Table

Name temperatureProbeTable
Object ID 1.3.6.1.4.1.674.10892.1.700.20
Description Defines the Temperature Probe Table.
Syntax TemperatureProbeTableEntry
Access Not accessible

Thermal Group 213


book.book Page 214 Monday, March 14, 2011 3:01 PM

Temperature Probe Table Entry

Name temperatureProbeTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1
Description Defines the Temperature Probe Table entry.
Syntax TemperatureProbeTableEntry
Access Not accessible
Index temperatureProbechassisIndex,
temperatureProbeIndex

Temperature Probe Chassis Index

Name temperatureProbechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Temperature Probe Index

Name temperatureProbeIndex
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.2
Description Defines the index of temperature probes in this chassis.
Syntax DellObjectRange
Access Read-only

Temperature Probe State Capabilities

Name temperatureProbeStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.3
Description Defines the capabilities of the temperature probe.
Syntax DellStateCapabilities
Access Read-only

214 Thermal Group


book.book Page 215 Monday, March 14, 2011 3:01 PM

Temperature Probe State Settings

Name temperatureProbeStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.4
Description Defines the state and settings of the temperature probe.
Syntax DellStateSettings
Access Read-write

Temperature Probe Status

Name temperatureProbeStatus
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.5
Description Defines the status of the temperature probe in tenths of degrees
Celsius.
Syntax DellStatusProbe
Access Read-only

Temperature Probe Reading

Name temperatureProbeReading
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.6
Description Defines the value of the temperature probe.
When the value for temperatureProbeType is other than
temperatureProbeTypeIsDiscrete, the value returned for this
attribute is the temperature that the probe is reading in tenths
of degrees Centigrade. When the value for
temperatureProbeType is temperatureProbeTypeIsDiscrete,
a value is not returned for this attribute.
Syntax DellSigned32BitRange
Access Read-only

Thermal Group 215


book.book Page 216 Monday, March 14, 2011 3:01 PM

Temperature Probe Type

Name temperatureProbeType
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.7
Description Defines the temperature probe type.
Syntax DellTemperatureProbeType (See Table 10-4)
Access Read-only

Temperature Probe Location Name

Name temperatureProbeLocationName
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.8
Description Defines the location of the temperature probe in this chassis.
Syntax DellString
Access Read-only

Temperature Probe Upper Nonrecoverable Threshold

Name temperatureProbeUpperNonRecoverableThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.9
Description Defines the value of the temperature probe’s upper
nonrecoverable threshold.
Syntax DellSigned32BitRange
Access Read-only

Temperature Probe Upper Critical Threshold

Name temperatureProbeUpperCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.10
Description Defines the value of the temperature probe’s upper critical
threshold.
Syntax DellSigned32BitRange
Access Read-only

216 Thermal Group


book.book Page 217 Monday, March 14, 2011 3:01 PM

Temperature Probe Upper Noncritical Threshold

Name temperatureProbeUpperNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.11
Description Defines the user-assigned value of the temperature probe’s
upper noncritical threshold.
Syntax DellSigned32BitRange
Access Read-write

Temperature Probe Lower Noncritical Threshold

Name temperatureProbeLowerNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.12
Description Defines the user-assigned value of the temperature probe’s
lower noncritical threshold.
Syntax DellSigned32BitRange
Access Read-write

Temperature Probe Lower Critical Threshold

Name temperatureProbeLowerCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.13
Description Defines the value of the temperature probe’s lower critical threshold.
Syntax DellSigned32BitRange
Access Read-only

Temperature Probe Lower Nonrecoverable Threshold

Name temperatureProbeLowerNonRecoverableThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.14
Description Defines the value of the temperature probe’s lower
nonrecoverable threshold.
Syntax DellSigned32BitRange
Access Read-only

Thermal Group 217


book.book Page 218 Monday, March 14, 2011 3:01 PM

Temperature Probe Probe Capabilities

Name temperatureProbeProbeCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.15
Description Defines the probe capabilities of the temperature probe.
Syntax DellProbeCapabilities
Access Read-only

Temperature Probe Discrete Reading

Name temperatureProbeDiscreteReading
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.16
Description Defines the reading for a temperature probe of type
temperatureProbeTypeIsDiscrete.
When the value for temperatureProbeType is other than
temperatureProbeTypeIsDiscrete, a value is not returned for this
attribute. When the value for temperatureProbeType is
temperatureProbeTypeIsDiscrete, the value returned for this
attribute is the discrete reading for the probe.
Syntax DellTemperatureDiscreteReading (See Table 10-5)
Access Read-only

218 Thermal Group


book.book Page 219 Monday, March 14, 2011 3:01 PM

Thermal Group Variable Values


This section includes definitions for server administrator-specific variable
values used in this section.

Table 10-1. Cooling Device Type

Variable Name: DellCoolingDeviceType


Data Type: Integer
Possible Data Values Meaning of Data Value
coolingDeviceTypeIsOther(1) The cooling device type is not
one of the following:
coolingDeviceTypeIsUnknown(2) The cooling device type is
unknown (not known or not
monitored).
coolingDeviceTypeIsAFan(3) The cooling device type is
a fan.
coolingDeviceTypeIsABlower(4) The cooling device type is a
centrifugal blower.
coolingDeviceTypeIsAChipFan(5) The cooling device type is a
fan on an integrated circuit.
coolingDeviceTypeIsACabinetFan(6) The cooling device type is a
cabinet fan.
coolingDeviceTypeIsAPowerSupplyFan(7) The cooling device type is a
power supply fan.
coolingDeviceTypeIsAHeatPipe(8) The cooling device type is a
heat pipe.
coolingDeviceTypeIsRefrigeration(9) The cooling device type is an
integrated refrigeration unit.
coolingDeviceTypeIsActiveCooling(10) The cooling device type is an
active cooling device.
coolingDeviceTypeIsPassiveCooling(11) The cooling device type is a
passive cooling device.

Thermal Group 219


book.book Page 220 Monday, March 14, 2011 3:01 PM

Table 10-2. Cooling Device Subtype

Variable Name: DellCoolingDeviceSubType


Data Type: Integer
Possible Data Values Meaning of Data Value
coolingDeviceSubTypeIsOther(1) The cooling device subtype is
not one of the following:
coolingDeviceSubTypeIsUnknown(2) The cooling device subtype is
unknown (not known or
not monitored).
coolingDeviceSubTypeIsAFanThatReads The cooling device subtype is a
InRPM(3) fan that reads in RPMs.
coolingDeviceSubTypeIsAFanReadsONor The cooling device subtype is a
OFF(4) fan that reads 0 (off) or 1 (on).
coolingDeviceSubTypeIsAPowerSupply The cooling device subtype is a
FanThatReadsinRPM(5) power supply fan that reads in
RPMs.
coolingDeviceSubTypeIsAPowerSupply The cooling device subtype is a
FanThatReads- ONorOFF(6) power supply fan that
reads 0 (off) or 1 (on).
coolingDeviceSubTypeIsDiscrete(16) The cooling device subtype is a
cooling device with
discrete reading.

Table 10-3. Cooling Device Discrete Reading

Variable Name: DellCoolingDeviceDiscreteReading


Data Type: Integer
Possible Data Values Meaning of Data Value
coolingDeviceIsGood(1) The cooling device discrete reading is good.
coolingDeviceIsBad(2) The cooling device discrete reading is bad.

220 Thermal Group


book.book Page 221 Monday, March 14, 2011 3:01 PM

Table 10-4. Temperature Probe Type

Variable Name: DellTemperatureProbeType


Data Type: Integer
Possible Data Values Meaning of Data Value
temperatureProbeTypeIsOther(1) The temperature probe subtype
is not one of the following:
temperatureProbeTypeIsUnknown(2) The temperature probe subtype
is unknown (not known or not
monitored).
temperatureProbeTypeIsAmbientESM(3) The temperature probe is for
ambient Embedded Systems
Management (ESM).
temperatureProbeTypeIsDiscrete(16) The temperature probe subtype
is a temperature probe with
discrete reading.

Table 10-5. Temperature Probe Discrete Reading

Variable Name: DellTemperatureDiscreteReading


Data Type: Integer
Possible Data Values Meaning of Data Value
temperatureIsGood(1) The temperature probe discrete reading is good.
temperatureIsBad(2) The temperature probe discrete reading is bad.

Thermal Group 221


book.book Page 222 Monday, March 14, 2011 3:01 PM

222 Thermal Group


book.book Page 223 Monday, March 14, 2011 3:01 PM

11
User Security Group
The User Security Table defines the objects that allow administrators to
create and modify user accounts and to control which users can perform Set
operations on managed systems.

User Security Group Table


The User Security Group defines objects in the User Security MIB table.

User Security Table


The following object sets up the User Security Table:

Name userSecurityTable
Object ID 1.3.6.1.4.1.674.10892.1.800
Description Contains the database of users that are authorized to perform
Set operations on a managed system.
Syntax UserSecurityTableEntry
Access Not accessible

User Security Table Entry

Name userSecurityTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.800.1
Description Defines a row in the User Security Table.
Syntax UserSecurityTableEntry
Access Not accessible
Index userSecuritychassisIndex, userSecurityIndex

User Security Group 223


book.book Page 224 Monday, March 14, 2011 3:01 PM

User Security Chassis Index

Name userSecuritychassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.800.1.1
Description Defines the user security index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

User Security Index

Name userSecurityIndex
Object ID 1.3.6.1.4.1.674.10892.1.800.1.2
Description Defines the user security index.
Syntax DellObjectRange
Access Read-only

User Security User Name

Name userSecurityUserName
Object ID 1.3.6.1.4.1.674.10892.1.800.1.3
Description Defines the user security user name.
Syntax DellSecurityString
Access Read-only

User Security Control Name

Name userSecurityControlName
Object ID 1.3.6.1.4.1.674.10892.1.800.1.4
Description Defines a control name used for creating, deleting, and editing
users.
Syntax DellSecurityString
Access Read-write

224 User Security Group


book.book Page 225 Monday, March 14, 2011 3:01 PM

User Security Request Name

Name userSecurityRequestName
Object ID 1.3.6.1.4.1.674.10892.1.800.1.5
Description Defines a request name used for creating, deleting, and editing
users.
Syntax DellSecurityString
Access Read-write

User Security Group 225


book.book Page 226 Monday, March 14, 2011 3:01 PM

226 User Security Group


book.book Page 227 Monday, March 14, 2011 3:01 PM

12
Remote Flash BIOS Group
The Remote Flash Basic Input/Output System (BIOS) Table defines the
variables used to remotely update the BIOS in a system. The variables also
define the capabilities of BIOS updates on the system.

Remote Flash BIOS Group Table


The Remote Flash BIOS Group defines objects in the Remote Flash BIOS
MIB table.

Remote Flash BIOS Table


The following object sets up the Remote Flash BIOS Table:

Name remoteFlashBIOSTable
Object ID 1.3.6.1.4.1.674.10892.1.900.10
Description Defines the Remote Flash BIOS Table.
Syntax RemoteFlashBIOSTableEntry
Access Not accessible

Remote Flash BIOS Table Entry

Name remoteFlashBIOSTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1
Description Defines the Remote Flash BIOS Table entry.
Syntax RemoteFlashBIOSTableEntry
Access Not accessible
Index remoteFlashBIOSchassisIndex, remoteFlashBIOSIndex

Remote Flash BIOS Group 227


book.book Page 228 Monday, March 14, 2011 3:01 PM

Remote Flash BIOS Chassis Index

Name remoteFlashBIOSchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Remote Flash BIOS Index

Name remoteFlashBIOSIndex
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.2
Description Defines the index to the remote BIOS update hardware on this
system.
Syntax DellObjectRange
Access Read-only

Remote Flash BIOS State Capabilities Unique

Name remoteFlashBIOSStateCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.3
Description Defines the capabilities of the remote BIOS update hardware on
this system.
Syntax DellRemoteFlashBIOSStateCapabilitiesUnique (See Table 12-1)
Access Read-only

Remote Flash BIOS State Settings Unique

Name remoteFlashBIOSStateSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.4
Description Defines the state and settings of the remote BIOS update
hardware on this system.
Syntax DellRemoteFlashBIOSStateSettingsUnique (See Table 12-2)
Access Read-write

228 Remote Flash BIOS Group


book.book Page 229 Monday, March 14, 2011 3:01 PM

Remote Flash BIOS Status

Name remoteFlashBIOSStatus
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.5
Description Defines the status of the remote BIOS update hardware on
this system.
Syntax DellRemoteFlashBIOSStateStatus
Access Read-only

Remote Flash BIOS Last BIOS Date Name

Name remoteFlashBIOSLastBIOSDateName
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.6
Description Defines the date of the last BIOS update.
Syntax DellDateName
Access Read-only

Remote Flash BIOS Completion Code

Name remoteFlashBIOSCompletionCode
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.7
Description Defines the completion code of the last BIOS update.
Syntax DellRemoteFlashBIOSCompletionCode (See Table 12-3 on
page 231)
Access Read-only

Remote Flash BIOS Minimum Contiguous Memory

Name remoteFlashBIOSMinimumContiguousMemory
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.8
Description Defines the minimum size of contiguous memory required for
remote BIOS update in kilobytes.
Syntax DellUnsigned32BitRange
Access Read-only

Remote Flash BIOS Group 229


book.book Page 230 Monday, March 14, 2011 3:01 PM

Remote Flash BIOS Variable Values


This section includes definitions for server administrator-specific variable
values used in this section.

Table 12-1. Remote Flash BIOS State Capabilities Unique

Variable Name: DellRemoteFlashBIOSStateCapabilitiesUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The remote flash BIOS’s capabilities are
unknown.
enableCapable(2) The remote flash BIOS can be disabled
(offline, a binary 0 value) or enabled (online,
a binary 1 value).
notReadyCapable(4) The remote flash BIOS can be set to
indicate not ready.
cancelCapable(8) Flash of BIOS can be canceled.
enableAndCancelCapable(10) Flash of BIOS can be enabled or canceled.

Table 12-2. Remote Flash BIOS State Settings

Variable Name: DellRemoteFlashBIOSStateSettingsUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The remote flash BIOS’s capabilities are unknown.
enabled(2) The remote flash BIOS update is disabled (offline, a
binary 0 value) or enabled (online, a binary 1 value).
notReady(4) The remote flash BIOS’s state is not ready.
canceled(8) The remote flash BIOS has been canceled.
pending(16) The remote flash BIOS update is pending.
other(32) The remote flash BIOS state/setting is not one of
the previous values.

230 Remote Flash BIOS Group


book.book Page 231 Monday, March 14, 2011 3:01 PM

Table 12-3. Remote Flash BIOS Completion Code

Variable Name: DellRemoteFlashBIOSCompletionCode


Data Type: Integer
Possible Data Values Meaning of Data Value
completionCodeIsOther(1) The completion code status is
not one of the following:
completionCodeIsUnknown(2) The completion code is unknown
(not known or not monitored).
completionCodeIsOK(3) This completion code completed
successfully.
completionCodeIsBadImage(4) This completion code is a bad
flash BIOS image.
completionCodeIsNoFileAccess(5) Flash BIOS could not be
accessed.
completionCodeIsNotReady(6) Flash BIOS memory not ready.
completionCodeIsDisabled(7) Flash BIOS is currently disabled.
completionCodeIsNoBattery(8) A battery must be installed.
completionCodeIsNoChargedBattery(9) A fully charged battery must be
installed.
completionCodeIsNoExternalPower(10) An external power adapter must
be connected.
completionCodeIsNo12VoltSet(11) 12 volts (V) could not be set.
completionCodeIsNo12VoltRemoval(12) 12 V could not be removed.
completionCodeIsFlashMemoryFailed A flash memory failure occurred.
(13)
completionCodeIsGeneralFailure(14) A general failure occurred.
completionCodeIsDataMiscompare(15) A data miscompare error
occurred.
completionCodeIsNoImageFound(16) The flash BIOS image could not
be found in memory.
completionCodeIsNoUpdatePerformed No update operation has been
(17) performed.

Remote Flash BIOS Group 231


book.book Page 232 Monday, March 14, 2011 3:01 PM

232 Remote Flash BIOS Group


book.book Page 233 Monday, March 14, 2011 3:01 PM

13
Port Group
The Port Group provides information about the different types of ports that
may be present in your system. This management information base (MIB)
group also provides information about the capabilities, states, and settings
that are possible for each port.

Port Group Tables


The following MIB tables define objects in the Port Group:
• "Pointing Port Table" on page 233
• "Keyboard Port Table" on page 236
• "Processor Port Table" on page 239
• "Memory Device Port Table" on page 242
• "Monitor Port Table" on page 245
• "Small Computer System Interface (SCSI) Port Table" on page 248
• "Parallel Port Table" on page 250
• "Serial Port Table" on page 254
• "Universal Serial Bus (USB) Port Table" on page 258

Pointing Port Table

Name pointingPortTable
Object ID 1.3.6.1.4.1.674.10892.1.1000.10
Description Defines the Pointing Port Table.
Syntax IntegerPointingPortTableEntry
Access Not accessible

Port Group 233


book.book Page 234 Monday, March 14, 2011 3:01 PM

Pointing Port Table Entry

Name pointingPortTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1
Description Defines the Pointing Port Table entry.
Syntax PointingPortTableEntry
Access Not accessible
Index pointingPortchassisIndex, pointingPortIndex

Pointing Port Chassis Index

Name pointingPortchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Pointing Port Index

Name pointingPortIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.2
Description Defines the index of the pointing ports in this chassis.
Syntax DellObjectRange
Access Read-only

Pointing Port State Capabilities

Name pointingPortStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1000.10.3
Description Defines the capabilities of the pointing port.
Syntax DellStateCapabilities
Access Read-only

234 Port Group


book.book Page 235 Monday, March 14, 2011 3:01 PM

Pointing Port State Settings

Name pointingPortStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1000.10.4
Description Defines the state and settings of the pointing port.
Syntax DellStateSettings
Access Read-write

Pointing Port Status

Name pointingPortStatus
Object ID 1.3.6.1.4.1.674.10892.1.1000.10.5
Description Defines the status of the pointing port.
Syntax DellStatus
Access Read-only

Pointing Port Security State

Name pointingPortSecurityState
Object ID 1.3.6.1.4.1.674.10892.1.1000.10.6
Description Defines the security settings of the pointing port.
Syntax DellPortSecurityState
Access Read-only

Pointing Port Connector Type

Name pointingPortConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.10.7
Description Defines the connector type of the pointing port.
Syntax DellPointingPortConnectorType (See Table 13-1)
Access Read-only

Port Group 235


book.book Page 236 Monday, March 14, 2011 3:01 PM

Pointing Port Name

Name pointingPortName
Object ID 1.3.6.1.4.1.674.10892.1.1000.10.8
Description Defines the name of the pointing port.
Syntax DellString
Access Read-only

Pointing Port BIOS Connector Type

Name pointingPortBIOSConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.10.9
Description Defines the basic input/output system (BIOS) connector type of
the pointing port.
Syntax DellGenericPortConnectorType
Access Read-only

Keyboard Port Table

Name keyboardPortTable
Object ID 1.3.6.1.4.1.674.10892.1.1000.20
Description Defines the Keyboard Port Table.
Syntax IntegerKeyboardPortTableEntry
Access Not accessible

Keyboard Port Table Entry

Name keyboardPortTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1
Description Defines the Keyboard Port Table entry.
Syntax KeyboardPortTableEntry
Access Not accessible
Index keyboardPortchassisIndex, keyboardPortIndex

236 Port Group


book.book Page 237 Monday, March 14, 2011 3:01 PM

Keyboard Port Chassis Index

Name keyboardPortchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Keyboard Port Index

Name keyboardPortIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.2
Description Defines the index of the keyboard ports in this chassis.
Syntax DellObjectRange
Access Read-only

Keyboard Port State Capabilities

Name keyboardPortStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.3
Description Defines the capabilities of the keyboard port.
Syntax DellStateCapabilities
Access Read-only

Keyboard Port State Settings

Name keyboardPortStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.4
Description Defines the state and settings of the keyboard port.
Syntax DellStateSettings
Access Read-only

Port Group 237


book.book Page 238 Monday, March 14, 2011 3:01 PM

Keyboard Port Status

Name keyboardPortStatus
Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.5
Description Defines the status of the keyboard port.
Syntax DellStatus
Access Read-only

Keyboard Port Security State

Name keyboardPortSecurityState
Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.6
Description Defines the security settings of the keyboard port.
Syntax DellPortSecurityState
Access Read-only

Keyboard Port Connector Type

Name keyboardPortConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.7
Description Defines the connector type of the keyboard port.
Syntax DellKeyboardPortConnectorType (See Table 13-2)
Access Read-only

Keyboard Port Name

Name keyboardPortName
Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.8
Description Defines the name of the keyboard port.
Syntax DellString
Access Read-only

238 Port Group


book.book Page 239 Monday, March 14, 2011 3:01 PM

Keyboard Port BIOS Connector Type

Name keyboardPortBIOSConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.9
Description Defines the BIOS connector type of the keyboard port.
Syntax DellGenericPortConnectorType
Access Read-only

Processor Port Table

Name processorPortTable
Object ID 1.3.6.1.4.1.674.10892.1.1000.30
Description Defines the Processor Port Table.
Syntax IntegerProcessorPortTableEntry
Access Not accessible

Processor Port Table Entry

Name processorPortTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1
Description Defines the Processor Port Table entry.
Syntax ProcessorPortTableEntry
Access Not accessible
Index processorPortchassisIndex, processorPortIndex

Processor Port Chassis Index

Name processorPortchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Port Group 239


book.book Page 240 Monday, March 14, 2011 3:01 PM

Processor Port Index

Name processorPortIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.2
Description Defines the index of the processor ports in this chassis.
Syntax DellObjectRange
Access Read-only

Processor Port State Capabilities

Name processorPortStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.3
Description Defines the capabilities of the processor port.
Syntax DellStateCapabilities
Access Read-only

Processor Port State Settings

Name processorPortStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.4
Description Defines the state and settings of the processor port.
Syntax DellStateSettings
Access Read-write

Processor Port Status

Name processorPortStatus
Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.5
Description Defines the status of the processor port.
Syntax DellStatus
Access Read-only

240 Port Group


book.book Page 241 Monday, March 14, 2011 3:01 PM

Processor Port Security State

Name processorPortSecurityState
Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.6
Description Defines the security settings of the processor port.
Syntax DellPortSecurityState
Access Read-only

Processor Port Connector Type

Name processorPortConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.7
Description Defines the connector type of the processor port.
Syntax DellProcessorPortConnectorType (See Table 13-3)
Access Read-only

Processor Port Name

Name processorPortName
Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.8
Description Defines name of the processor port.
Syntax DellString
Access Read-only

Processor Port BIOS Connector Type

Name processorPortBIOSConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.9
Description Defines the BIOS connector type of the processor port.
Syntax DellGenericPortConnectorType
Access Read-only

Port Group 241


book.book Page 242 Monday, March 14, 2011 3:01 PM

Memory Device Port Table

Name memoryDevicePortTable
Object ID 1.3.6.1.4.1.674.10892.1.1000.40
Description Defines the Memory Device Port Table.
Syntax IntegerMemoryDevicePortTableEntry
Access Not accessible

Memory Device Port Table Entry

Name memoryDevicePortTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1
Description Defines the Memory Device Port Table entry.
Syntax MemoryDevicePortTableEntry
Access Not accessible
Index memoryDevicePortchassisIndex, memoryDevicePortIndex

Memory Device Port Chassis Index

Name memoryDevicePortchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Memory Device Port Index

Name memoryDevicePortIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.2
Description Defines the index of the memory device port in this chassis.
Syntax DellObjectRange
Access Read-only

242 Port Group


book.book Page 243 Monday, March 14, 2011 3:01 PM

Memory Device Port State Capabilities

Name memoryDevicePortStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.3
Description Defines the capabilities of the memory device port.
Syntax DellStateCapabilities
Access Read-only

Memory Device Port State Settings

Name memoryDevicePortStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.4
Description Defines the state and settings of the memory device port.
Syntax DellStateSettings
Access Read-write

Memory Device Port Status

Name memoryDevicePortStatus
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.5
Description Defines the status of the memory device port.
Syntax DellStatus
Access Read-only

Memory Device Port Security State

Name memoryDevicePortSecurityState
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.6
Description Defines the security settings of the memory device port.
Syntax DellPortSecurityState
Access Read-only

Port Group 243


book.book Page 244 Monday, March 14, 2011 3:01 PM

Memory Device Port Connector Type

Name memoryDevicePortConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.7
Description Defines the connector type of the memory device port.
Syntax DellMemoryDevicePortConnectorType (See Table 13-4)
Access Read-only

Memory Device Port Name

Name memoryDevicePortName
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.8
Description Defines the name of the memory device port.
Syntax DellString
Access Read-only

Memory Device Port BIOS Connector Type

Name memoryDevicePortBIOSConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.9
Description Defines the BIOS connector type of the memory device port.
Syntax DellGenericPortConnectorType
Access Read-only

Memory Device Port Physical Memory Array Index Reference

Name memoryDevicePortPhysicalMemoryArrayIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.10
Description Defines the index to the associated physical memory array.
Syntax DellUnsigned32BitRange
Access Read-only

244 Port Group


book.book Page 245 Monday, March 14, 2011 3:01 PM

Memory Device Port Physical Memory Card Index Reference

Name memoryDevicePortPhysicalMemoryCardIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.11
Description Defines the index (one-based) of the Physical Memory Card Table
entry for the physical memory card with the same chassis index that
this memory device port is associated with (if any).
Syntax DellUnsigned32BitRange
Access Read-only

Monitor Port Table


Name monitorPortTable
Object ID 1.3.6.1.4.1.674.10892.1.1000.50
Description Defines the Monitor Port Table.
Syntax IntegerMonitorPortTableEntry
Access Not accessible

Monitor Port Table Entry

Name monitorPortTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1
Description Defines the Monitor Port Table entry.
Syntax MonitorPortTableEntry
Access Not accessible
Index monitorPortchassisIndex, monitorPortIndex

Monitor Port Chassis Index

Name monitorPortchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.1
Description Defines the index (one-based) of this chassis
Syntax DellObjectRange
Access Read-only

Port Group 245


book.book Page 246 Monday, March 14, 2011 3:01 PM

Monitor Port Index

Name monitorPortIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2
Description Defines the index of the monitor ports in this chassis.
Syntax DellObjectRange
Access Read-only

Monitor Port State Capabilities

Name monitorPortStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.3
Description Defines the capabilities of the monitor port.
Syntax DellStateCapabilities
Access Read-only

Monitor Port State Settings

Name monitorPortStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.4
Description Defines the state of the monitor port.
Syntax DellStateSettings
Access Read-write

Monitor Port Status

Name monitorPortStatus
Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.5
Description Defines the status of the monitor port.
Syntax DellStatus
Access Read-only

246 Port Group


book.book Page 247 Monday, March 14, 2011 3:01 PM

Monitor Port Security State

Name monitorPortSecurityState
Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.6
Description Defines the security settings of the monitor port.
Syntax DellPortSecurityState
Access Read-only

Monitor Port Connector Type

Name monitorPortConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7
Description Defines the connector type of the monitor port.
Syntax DellMonitorPortConnectorTypes (See Table 13-5)
Access Read-only

Monitor Port Name

Name monitorPortName
Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.8
Description Defines the name of the monitor port.
Syntax DellString
Access Read-only

Monitor Port BIOS Connector Type

Name monitorPortBIOSConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.9
Description Defines the name of the BIOS connector type of the monitor port.
Syntax DellGenericPortConnectorType
Access Read-only

Port Group 247


book.book Page 248 Monday, March 14, 2011 3:01 PM

Small Computer System Interface (SCSI) Port Table

Name sCSIPortTable
Object ID 1.3.6.1.4.1.674.10892.1.1000.60
Description Defines the SCSI Port Table.
Syntax IntegerSCSIPortTableEntry
Access Not accessible

SCSI Port Table Entry

Name sCSIPortTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1
Description Defines the SCSI Port Table entry.
Syntax SCSIPortTableEntry
Access Not accessible
Index sCSIPortchassisIndex, sCSIPortIndex

SCSI Port Chassis Index

Name sCSIPortchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.1
Description Defines the index (one-based) of this chassis
Syntax DellObjectRange
Access Read-only

SCSI Port Index

Name sCSIPortIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.2
Description Defines the index of the SCSI ports in this chassis.
Syntax DellObjectRange
Access Read-only

248 Port Group


book.book Page 249 Monday, March 14, 2011 3:01 PM

SCSI Port State Capabilities

Name sCSIPortStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.3
Description Defines the capabilities of the SCSI port.
Syntax DellStateCapabilities
Access Read-only

SCSI Port State Settings

Name DellStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.4
Description Defines the state and settings of the SCSI port.
Syntax DellStatus
Access Read-write

SCSI Port Status

Name sCSIPortStatus
Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.5
Description Defines the status of the SCSI port.
Syntax DellStatus
Access Read-only

SCSI Port Security State

Name sCSIPortSecurityState
Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.6
Description Defines the security settings of the SCSI port.
Syntax DellPortSecurityState
Access Read-only

Port Group 249


book.book Page 250 Monday, March 14, 2011 3:01 PM

SCSI Port Connector Type

Name sCSIPortConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.7
Description Defines the connector type of the SCSI port.
Syntax DellSCSIPortConnectorType (See Table 13-6)
Access Read-only

SCSI Port Name

Name sCSIPortName
Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.8
Description Defines the name of the SCSI port.
Syntax DellString
Access Read-only

SCSI Port BIOS Connector Type

Name sCSIPortBIOSConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.9
Description Defines the BIOS connector type of the SCSI port.
Syntax DellGenericPortConnectorType
Access Read-only

Parallel Port Table

Name parallelPortTable
Object ID 1.3.6.1.4.1.674.10892.1.1000.70
Description Defines the Parallel Port Table.
Syntax IntegerParallelPortTableEntry
Access Not accessible

250 Port Group


book.book Page 251 Monday, March 14, 2011 3:01 PM

Parallel Port Table Entry

Name parallelPortTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1
Description Defines the Parallel Port Table entry.
Syntax ParallelPortTableEntry
Access Not accessible
Index parallelPortchassisIndex, parallelPortIndex

Parallel Port Chassis Index

Name parallelPortchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Parallel Port Index

Name parallelPortIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.2
Description Defines the index of the parallel ports in this chassis.
Syntax DellObjectRange
Access Read-only

Parallel Port State Capabilities

Name parallelPortStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.3
Description Defines the capabilities of the parallel port.
Syntax DellStateSettings
Access Read-write

Port Group 251


book.book Page 252 Monday, March 14, 2011 3:01 PM

Parallel Port State Settings

Name parallelPortStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.4
Description Defines the state and settings of the parallel port.
Syntax DellStateSettings
Access Read-write

Parallel Port Status

Name parallelPortStatus
Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.5
Description Defines the status of the parallel port.
Syntax DellStatus
Access Read-only

Parallel Port Security State

Name DellPortSecurityState
Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.6
Description Defines the security state of the parallel port.
Syntax DellStatus
Access Read-only

Parallel Port Connector Type

Name parallelPortConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.7
Description Defines the connector type of the parallel port.
Syntax DellParallelPortConnectorType
Access Read-only

252 Port Group


book.book Page 253 Monday, March 14, 2011 3:01 PM

Parallel Port Name

Name parallelPortName
Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.8
Description Defines the name of the parallel port.
Syntax DellString
Access Read-only

Parallel Port Connector Pin Out

Name parallelPortConnectorPinOut
Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.9
Description Defines the pinout of the parallel port.
Syntax DellParallelPortConnectorPinout
Access Read-only

Parallel Port Capabilities Unique

Name parallelPortCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.10
Description Defines the capabilities of the parallel port.
Syntax DellParallelPortConnectorPinout
Access Read-only

Parallel Port Base I/O Address

Name parallelPortBaseIOAddress
Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.11
Description Defines the Base Input/Output (I/O) address of the parallel port.
Syntax DellUnsigned64BitRange
Access Read-only

Port Group 253


book.book Page 254 Monday, March 14, 2011 3:01 PM

Parallel Port IRQ Level

Name parallelPortIRQLevel
Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.12
Description Defines the Interrupt Request Level (IRQ) of the parallel port.
Syntax DellUnsigned8BitRange
Access Read-only

Parallel Port DMA Support

Name parallelPortDMASupport
Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.13
Description Defines if direct memory access (DMA) is supported by the
parallel port.
Syntax DellBoolean
Access Read-only

Serial Port Table

Name serialPortTable
Object ID 1.3.6.1.4.1.674.10892.1.1000.80
Description Defines the Serial Port Table.
Syntax IntegerSerialPortTableEntry
Access Not accessible

Serial Port Table Entry

Name serialPortTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1
Description Defines the Serial Port Table entry.
Syntax SerialPortTableEntry
Access Not accessible
Index serialPortchassisIndex, serialPortIndex

254 Port Group


book.book Page 255 Monday, March 14, 2011 3:01 PM

Serial Port Chassis Index

Name serialPortchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Serial Port Index

Name serialPortIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.2
Description Defines the index of the serial ports in this chassis.
Syntax DellObjectRange
Access Read-only

Serial Port State Capabilities

Name serialPortStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.3
Description Defines the capabilities of the serial port.
Syntax DellStateCapabilities
Access Read-only

Serial Port State Settings

Name serialPortStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.4
Description Defines the state and settings of the serial port.
Syntax DellStateSettings
Access Read-write

Port Group 255


book.book Page 256 Monday, March 14, 2011 3:01 PM

Serial Port Status

Name serialPortStatus
Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.5
Description Defines the status of the serial port.
Syntax DellStatus
Access Read-only

Serial Port Security State

Name serialPortSecurityState
Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.6
Description Defines the security settings of the serial port.
Syntax DellPortSecurityState
Access Read-only

Serial Port Connector Type

Name serialPortConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.7
Description Defines connector type of the serial port.
Syntax DellSerialPortConnectorType
Access Read-only

Serial Port Name

Name serialPortName
Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.8
Description Defines the name of the serial port.
Syntax DellString
Access Read-only

256 Port Group


book.book Page 257 Monday, March 14, 2011 3:01 PM

Serial Port Maximum Speed

Name serialPortMaximumSpeed
Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.9
Description Defines the maximum speed the serial interface can support in
bits per second (bps).
Syntax DellUnsigned32BitRange
Access Read-only

Serial Port Capabilities Unique

Name serialPortCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.10
Description Defines additional capabilities of the serial port.
Syntax DellSerialPortCapabilitiesUnique
Access Read-only

Serial Port Base I/O Address

Name serialPortBaseIOAddress
Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.11
Description Defines the base I/O address of the serial port.
Syntax DellUnsigned64BitRange
Access Read-only

Serial Port IRQ Level

Name serialPortIRQLevel
Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.12
Description Defines the IRQ of the serial port.
Syntax DellUnsigned8BitRange
Access Read-only

Port Group 257


book.book Page 258 Monday, March 14, 2011 3:01 PM

Universal Serial Bus (USB) Port Table

Name uSBPortTable
Object ID 1.3.6.1.4.1.674.10892.1.1000.90
Description Defines the USB Port Table.
Syntax IntegerUSBPortTableEntry
Access Not accessible

USB Port Table Entry

Name uSBPortTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1
Description Defines the USB Port Table entry.
Syntax USBPortTableEntry
Access Not accessible
Index uSBPortchassisIndex, uSBPortIndex

USB Port Chassis Index

Name uSBPortchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

USB Port Index

Name uSBPortIndex
Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.2
Description Defines the index of the USB ports in this chassis
Syntax DellObjectRange
Access Read-only

258 Port Group


book.book Page 259 Monday, March 14, 2011 3:01 PM

USB Port State Capabilities

Name uSBPortStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.3
Description Defines the capabilities of the USB port.
Syntax DellStateCapabilities
Access Read-only

USB Port State Settings

Name uSBPortStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.4
Description Defines the state and settings of the USB port.
Syntax DellStateSettings
Access Read-write

USB Port Status

Name uSBPortStatus
Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.5
Description Defines the state of the USB port.
Syntax DellStatus
Access Read-only

USB Port Security State

Name uSBPortSecurityState
Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.6
Description Defines the security settings of the USB port.
Syntax DellPortSecurityState
Access Read-only

Port Group 259


book.book Page 260 Monday, March 14, 2011 3:01 PM

USB Port Connector Type

Name uSBPortConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.7
Description Defines the connector type of the USB port.
Syntax DellUSBPortConnectorType
Access Read-only

USB Port Name

Name uSBPortName
Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.8
Description Defines the name of the USB port.
Syntax DellString
Access Read-only

USB Port BIOS Connector Type

Name uSBPortBIOSConnectorType
Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.9
Description Defines the BIOS connector type of the USB port.
Syntax DellGenericPortConnectorType
Access Read-only

260 Port Group


book.book Page 261 Monday, March 14, 2011 3:01 PM

Port Group Variable Values


This section includes definitions for server administrator-specific variable
values used in this section.

Table 13-1. Pointing Port Connector Type

Variable Name: DellPointingPortConnectorType


Data Type: Integer
Possible Data Values Meaning of Data Value
connectorPortTypeIsOther(1) The pointing port connector type is
not one of the following:
connectorPortTypeIsUnknown(2) The pointing port connector type is
unknown.
connectorPortTypeIsSerial(3) The pointing port connector type is
serial.
connectorPortTypeIsPS2(4) The pointing port connector type is a
Personal System/2 (PS/2).
connectorPortTypeIsInfrared(5) The pointing port connector type is
infrared.
connectorPortTypeIsHPHIL(6) The pointing port connector type is
HP-HIL.
connectorPortTypeIsBusMouse(7) The pointing port connector type is a
bus mouse.
connectorPortTypeIsADB(8) The pointing port connector type is
ADB.
connectorPortTypeIsDB9(9) The pointing port connector type is
nine-pin DB-9.
connectorPortTypeIsMicroDIN(10) The pointing port connector type is
micro Deutsche Industrie Norm
(DIN).
connectorPortTypeIsAccessBusUSB The pointing port connector type is
(11) Access Bus USB.
connectorPortTypeIsPC98(12) The port connector type is a PC-98.

Port Group 261


book.book Page 262 Monday, March 14, 2011 3:01 PM

Table 13-2. Keyboard Port Connector Types

Variable Name: DellKeyboardPortConnectorType


Data Type: Integer
Possible Data Values Meaning of Data Value
connectorPortTypeIsOther(1) The keyboard port connector
type is not one of the following:
connectorPortTypeIsUnknown(2) The keyboard port connector
type is unknown.
connectorPortTypeIsMiniDIN(3) The keyboard port connector
type is a mini DIN.
connectorPortTypeIsMicroDIN(4) The keyboard port connector
type is a MicroDIN.
connectorPortTypeIsPS2(5) The keyboard port connector
type is PS/2.
connectorPortTypeIsInfrared(6) The keyboard port connector
type is infrared.
connectorPortTypeIsHPHIL(7) The keyboard port connector
type is HP-HIL.
connectorPortTypeIsDB9(8) The keyboard port connector
type is DB-9.
connectorPortTypeIsAccessBusUSB(9) The keyboard port connector
type is bus USB.
connectorPortTypeIsPC98(10) The keyboard port connector
type is PC-98.

262 Port Group


book.book Page 263 Monday, March 14, 2011 3:01 PM

Table 13-3. Processor Port Connector Types

Variable Name: DellProcessorPortConnectorType


Data Type: Integer
Possible Data Values Meaning of Data Value
connectorPortTypeIsOther(1) The processor port connector
type is not one of the
following:
connectorPortTypeIsUnknown(2) The processor port connector
type is unknown.
connectorPortTypeIsDaughterdBoard(3) The processor port connector
type is a daughter board.
connectorPortTypeIsZIFSocket(4) The processor port connector
type is a zero insertion force
(ZIF) socket.
connectorPortTypeIsAPiggyBackBoard(5) The processor port connector
type is a replacement
piggyback board.
connectorPortTypeIsNone(6) There is no processor port
connector; processor is
soldered in place.
connectorPortTypeIsLIFSocket(7) The processor port connector
type is a low insertion force
(LIF) socket.
connectorPortTypeIsSlot1(8) The processor port connector
type is a slot one.
connectorPortTypeIsSlot2(9) The processor port connector
type is a slot two.
connectorPortTypeIs370PinSocket(10) The processor port connector
type is a 370 pin socket.

Port Group 263


book.book Page 264 Monday, March 14, 2011 3:01 PM

Table 13-4. Memory Device Port Connector Types

Variable Name: DellMemoryDevicePortConnectorType


Data Type: Integer
Possible Data Value Meaning of Data Value
connectorPortTypeIsOther(1) The memory device port
connector type is not one of
the following:
connectorPortTypeIsUnknown(2) The memory device port
connector type is unknown.
connectorPortTypeIsSIMM(3) The memory device port
connector type is a single
in-line memory module
(SIMM).
connectorPortTypeIsSIP(4) The memory device port
connector type is a SIP.
connectorPortTypeIsAChip(5) The memory device port
connector type is a chip.
connectorPortTypeIsDIP(6) The memory device port
connector type is a dual
in-line package (DIP).
connectorPortTypeIsZIP(7) The memory device port
connector type is a ZIP.
connectorPortTypeIsAProprietaryCard(8) The memory device port
connector type is a
proprietary card.
connectorPortTypeIsDIMM(9) The memory device port
connector type is a dual
in-line memory module
(DIMM).
connectorPortTypeIsTSOP(10) The memory device port
connector type is a TSOP.
connectorPortTypeIsARowOfChips(11) The memory device port
connector type is a row of
chips.

264 Port Group


book.book Page 265 Monday, March 14, 2011 3:01 PM

Table 13-4. Memory Device Port Connector Types (continued)

Variable Name: DellMemoryDevicePortConnectorType


Data Type: Integer
Possible Data Value Meaning of Data Value
connectorPortTypeIsRIMM(12) The memory device port
connector type is a Rambus
Inline Memory Module
(RIMM).
connectorPortTypeIsSODIMM(13) The memory device port
connector type is a small
outline, dual in-line
memory module
(SODIMM).
connectorPortTypeIsSRIMM(14) The memory device port
connector type is a SRIMM.

Table 13-5. Monitor Port Connector Types

Variable Name: DellMonitorPortConnectorType


Data Type: Integer
Possible Data Values Meaning of Data Value
connectorPortTypeIsOther(1) The monitor port connector type
is not one of the following:
connectorPortTypeIsUnknown(2) The monitor port connector type
is unknown.
connectorPortTypeIsDB15PinMale(3) The monitor port connector type
is a male DB-15.
connectorPortTypeIsDB15PinFemale(4) The monitor port connector type
is a female DB-15.

Port Group 265


book.book Page 266 Monday, March 14, 2011 3:01 PM

Table 13-6. SCSI Port Connector Types

Variable Name: DellSCSIPortConnectorType


Data Type: Integer
Possible Data Values Meaning of Data Value
connectorPortTypeIsOther(1) The SCSI port connector type
is not one of the following:
connectorPortTypeIsUnknown(2) The SCSI port connector type
is unknown.
connectorPortTypeIsDIN25pin(3) The SCSI port connector type
is a DIN 25-pin.
connectorPortTypeIsDIN50pin(4) The SCSI port connector type
is a DIN 50-pin.
connectorPortTypeIsDIN68pin(5) The SCSI port connector type
is a DIN 68-pin.

266 Port Group


book.book Page 267 Monday, March 14, 2011 3:01 PM

14
Device Group
The Device Group provides information about different types of pointing,
keyboard, processor, cache, memory, and peripheral component interconnect
(PCI) devices. Variables in this group cover information about type, settings,
configuration, manufacturer, address or location, and if applicable, the speed
of the device.

Device Tables
The following management information base (MIB) tables define objects in
the Device Group:
• "Pointing Device Table" on page 268
• "Keyboard Device Table" on page 270
• "Processor Device Table" on page 273
• "Processor Device Status Table" on page 281
• "Cache Device Table" on page 283
• "Memory Device Table" on page 289
• "Memory Device Mapped Address Table" on page 297
• "Generic Device Table" on page 300
• "PCI Device Table" on page 303
• "PCI Device Configuration Space Table" on page 306
• "Network Device Table" on page 309
• "Managed System Services Device Table" on page 317
• "SD Card Unit Table" on page 319
• "SD Card Device Table" on page 322

Device Group 267


book.book Page 268 Monday, March 14, 2011 3:01 PM

Pointing Device Table


Name pointingDeviceTable
Object ID 1.3.6.1.4.1.674.10892.1.1100.10
Description Defines the Pointing Device Table. This group of objects
references the Pointing Port Index (See Section 12).
Syntax SEQUENCE OF PointingDeviceTableEntry
Access Not accessible

Pointing Device Table Entry

Name pointingDeviceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1
Description Defines the Pointing Device Table entry.
Syntax PointingDeviceTableEntry
Access Not accessible
Index pointingDevicechassisIndex, pointingDeviceIndex

Pointing Device Chassis Index

Name pointingDevicechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Pointing Device Index

Name pointingDeviceIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.2
Description Defines the index of the pointing device in this chassis.
Syntax DellObjectRange
Access Read-only

268 Device Group


book.book Page 269 Monday, March 14, 2011 3:01 PM

Pointing Device State Capabilities

Name pointingDeviceStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.3
Description Defines the capabilities of the pointing device.
Syntax DellStateCapabilities
Access Read-only

Pointing Device State Settings

Name pointingDeviceStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.4
Description Defines the state of the pointing device.
Syntax DellStateSettings
Access Read-write

Pointing Device Status

Name pointingDeviceStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.5
Description Defines the status of the pointing device.
Syntax DellStatus
Access Read-only

Pointing Port Index Reference

Name pointingPortIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.6
Description Defines the index to the pointing port in this chassis.
Syntax DellObjectRange
Access Read-only

Device Group 269


book.book Page 270 Monday, March 14, 2011 3:01 PM

Pointing Device Type

Name pointingDeviceType
Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.7
Description Defines the type of the pointing device.
Syntax DellPointingDeviceType (See Table 14-1)
Access Read-only

Pointing Device Number of Buttons

Name pointingDeviceNumberofButtons
Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.8
Description Defines the number of buttons on the pointing device.
Syntax DellUnsigned8BitRange
Access Read-only

Keyboard Device Table

Name keyboardDeviceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.20
Description Defines the Keyboard Device Table. This table references the
Keyboard Port Index (See Section 12).
Syntax SEQUENCE OF KeyboardDeviceTableEntry
Access Not accessible

Keyboard Device Table Entry

Name keyboardDeviceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1
Description Defines the Keyboard Device Table entry.
Syntax KeyboardDeviceTableEntry
Access Not accessible
Index keyboardDevicechassisIndex, keyboardDeviceIndex

270 Device Group


book.book Page 271 Monday, March 14, 2011 3:01 PM

Keyboard Device Chassis Index

Name keyboardDevicechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Keyboard Device Index

Name keyboardDeviceIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.2
Description Defines the index of the keyboard device for this chassis.
Syntax DellObjectRange
Access Read-only

Keyboard Device State Capabilities

Name keyboardDeviceStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.3
Description Defines the capabilities of the keyboard device.
Syntax DellStateCapabilities
Access Read-only

Keyboard Device State Settings

Name keyboardDeviceStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.4
Description Defines the state of the keyboard device.
Syntax DellStatesSettings
Access Read-write

Device Group 271


book.book Page 272 Monday, March 14, 2011 3:01 PM

Keyboard Device Status

Name keyboardDeviceStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.5
Description Defines the status of the keyboard device.
Syntax DellStatus
Access Read-only

Keyboard Port Index Reference

Name keyboardPortIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.6
Description Defines the index to the associated the keyboard port in
this chassis.
Syntax DellStatus
Access Read-only

Keyboard Device Type Name

Name keyboardDeviceTypeName
Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.7
Description Defines the name of the keyboard type.
Syntax DellString
Access Read-only

Keyboard Device Layout Name

Name keyboardDeviceLayoutName
Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.8
Description Defines the name of the keyboard layout.
Syntax DellString
Access Read-only

272 Device Group


book.book Page 273 Monday, March 14, 2011 3:01 PM

Processor Device Table

Name processorDeviceTable
Object ID 1.3.6.1.4.1.674.10892.1.1100.30
Description Defines the Processor Device Table.
Syntax SEQUENCE OF ProcessorDeviceTableEntry
Access Not accessible

Processor Device Table Entry

Name processorDeviceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1
Description Defines the Processor Device Table entry.
Syntax ProcessorDeviceTableEntry
Access Not accessible
Index processorDevicechassisIndex, processorDeviceIndex

Processor Device Chassis Index

Name processorDevicechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Processor Device Index

Name processorDeviceIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.2
Description Defines the index of the processor device in this chassis.
Syntax DellObjectRange
Access Read-only

Device Group 273


book.book Page 274 Monday, March 14, 2011 3:01 PM

Processor Device State Capabilities

Name processorDeviceStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.3
Description Defines the capabilities of the processor device.
Syntax DellStateCapabilities
Access Read-only

Processor Device State Settings

Name processorDeviceStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.4
Description Defines the state of the processor device.
Syntax DellStateSettings
Access Read-write

Processor Device Status

Name processorDeviceStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.5
Description Defines the status of the processor device.
Syntax DellStatus
Access Read-only

Processor Port Index Reference

Name processorPortIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.6
Description Defines the index to the associated processor port in this
chassis.
Syntax DellObjectRange
Access Read-only

274 Device Group


book.book Page 275 Monday, March 14, 2011 3:01 PM

Processor Device Type

Name processorDeviceType
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.7
Description Defines the type of processor device.
Syntax DellProcessorDeviceType (See Table 14-4)
Access Read-only

Processor Device Manufacturer Name

Name processorDeviceManufacturerName
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.8
Description Defines the name of manufacturer of the processor device.
Syntax DellString
Access Read-only

Processor Device Status State

Name processorDeviceStatusState
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.9
Description Defines the status state of the processor device.
Syntax DellProcessorDeviceStatusState (See Table 14-2)
Access Read-only

Processor Device Family

Name processorDeviceFamily
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.10
Description Defines the family of the processor device.
Syntax DellProcessorDeviceFamily (See Table )
Access Read-only

Device Group 275


book.book Page 276 Monday, March 14, 2011 3:01 PM

Processor Device Maximum Speed

Name processorDeviceMaximumSpeed
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.11
Description Defines the maximum speed of the processor device in
megahertz (MHz). A zero (0) indicates that the speed is
unknown.
Syntax DellUnsigned32BitRange
Access Read-only

Processor Device Current Speed

Name processorDeviceCurrentSpeed
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.12
Description Defines the current speed of the processor device in MHz. A
zero (0) indicates that the speed is unknown.
Syntax DellUnsigned32BitRange
Access Read-only

Processor Device External Clock Speed

Name processorDeviceExternalClockSpeed
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.13
Description Defines the speed of the external clock (the front-side bus
speed) for the processor device in MHz. A zero (0) indicates
that the speed is unknown.
Syntax DellUnsigned32BitRange
Access Read-only

276 Device Group


book.book Page 277 Monday, March 14, 2011 3:01 PM

Processor Device Voltage

Name processorDeviceVoltage
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.14
Description Defines the voltage powering the processor device in millivolts.
A zero (0) indicates the speed is unknown.
Syntax DellSigned32BitRange
Access Read-only

Processor Device Upgrade Information

Name processorDeviceUpgradeInformation
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.15
Description Defines the processor upgrade information for the processor device.
Syntax DellProcessorUpgradeInformation (See Table 14-5)
Access Read-only

Processor Device Version Name

Name processorDeviceVersionName
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.16
Description Defines the version name of the processor device.
Syntax DellString
Access Read-only

Device Group 277


book.book Page 278 Monday, March 14, 2011 3:01 PM

Processor Device Core Count

Name processorDeviceCoreCount
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.17
Description Defines the number of processor cores detected for the
processor device.
Syntax DellUnsigned32BitRange
Access Read-only

Processor Device Core Enabled Count

Name processorDeviceCoreEnabledCount
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.18
Description Defines the number of processor cores enabled for the
processor device.
Syntax DellUnsigned32BitRange
Access Read-only

Processor Device Thread Count

Name processorDeviceThreadCount
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.19
Description Defines the number of processor threads detected for the
processor device.
Syntax DellUnsigned32BitRange
Access Read-only

278 Device Group


book.book Page 279 Monday, March 14, 2011 3:01 PM

Processor Device Characteristics

Name processorDeviceCharacteristics
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.20
Description This attribute defines characteristics of the processor device.
This attribute is a bit field where a bit has the meaning defined
below when set to 1 (one).
NOTE: Bits 2-15 need to be examined in the context of bit 1. If bit 1 is
set, the processor characteristics are unknown and bits 2-15
cannot be used to determine if the functions associated with the
bits are supported.
Bit Position Meaning if Set
-------------- ------------------
Bit 0 Reserved
Bit 1 Unknown
Bit 2 64-bit capable
Bit 3-15 Reserved
Syntax DellUnsigned16BitRange
Access Read-only

Processor Device Extended Capabilities

Name processorDeviceExtendedCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.21
Description This attribute defines extended capabilities of the processor
device. This attribute is a bit field where a bit has the meaning
defined below when set to 1 (one).
Bit Position Meaning if Set
---------------- -------------------
Bit 0 Virtualization Technology (VT) supported
Bit 1 Demand-Based Switching (DBS) supported
Bit 2 eXecute Disable (XD) supported
Bit 3 Hyper-Threading (HT) supported
Syntax DellUnsigned16BitRange
Access Read-only

Device Group 279


book.book Page 280 Monday, March 14, 2011 3:01 PM

Processor Device Extended Settings

Name processorDeviceExtendedSettings
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.22
Description This attribute defines extended settings of the processor device.
This attribute is a bit field where a bit has the meaning defined
below when set to 1 (one).
Bit Position Meaning if Set
--------------- -------------
Bit 0 Virtualization Technology (VT) enabled
Bit 1 Demand Based Switching (DBS) enabled
Bit 2 eXecute Disable (XD) enabled
Bit 3 Hyper-Threading (HT) enabled
Syntax DellUnsigned16BitRange
Access Read-only

Processor Device Brand Name

Name processorDeviceBrandName
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.23
Description Defines the brand of the processor device.
Syntax DellString
Access Read-only

Processor Device Model Name

Name processorDeviceModelName
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.24
Description Defines the model of the processor device.
Syntax DellString
Access Read-only

280 Device Group


book.book Page 281 Monday, March 14, 2011 3:01 PM

Processor Device Stepping Name

Name processorDeviceSteppingName
Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.25
Description Defines the stepping of the processor device.
Syntax DellString
Access Read-only

Processor Device Status Table

Name processorDeviceStatusTable
Object ID 1.3.6.1.4.1.674.10892.1.1100.32
Description Defines the Processor Device Status Table.
Syntax SEQUENCE OF ProcessorDeviceStatusTableEntry
Access Not accessible

Processor Device Status Table Entry

Name processorDeviceStatusTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1
Description Defines the Processor Device Status Table Entry.
Syntax ProcessorDeviceStatusTableEntry
Access Not accessible
Index processorDeviceStatusChassisIndex,
processorDeviceStatusIndex

Processor Device Status Chassis Index

Name processorDeviceStatusChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellObjectRange
Access Read-only

Device Group 281


book.book Page 282 Monday, March 14, 2011 3:01 PM

Processor Device Status Index

Name processorDeviceStatusIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2
Description Defines the index (one-based) of the processor device status
probe.
Syntax DellObjectRange
Access Read-only

Processor Device Status State Capabilities

Name processorDeviceStatusStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.3
Description Defines the state capabilities of the processor device status probe.
Syntax DellStateCapabilities
Access Read-only

Processor Device Status State Settings

Name processorDeviceStatusStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.4
Description Defines the state settings of the processor device status probe.
Syntax DellStateSettings
Access Read-write

Processor Device Status Status

Name processorDeviceStatusStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.5
Description Defines the status of the processor device status probe. This
status is joined into the processorDeviceStatus attribute.
Syntax DellStatus
Access Read-only

282 Device Group


book.book Page 283 Monday, March 14, 2011 3:01 PM

Processor Device Status Reading

Name processorDeviceStatusReading
Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.6
Description Defines the reading of the processor device status probe.
Syntax DellProcessorDeviceStatusReading
Access Read-only

Processor Device Status Location Name

Name processorDeviceStatusLocationName
Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.7
Description Defines the location name of the processor device status probe.
Syntax DellString
Access Read-only

Processor Device Status Port Index Reference

Name processorDeviceStatusPortIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.8
Description Defines the index (one-based) of the associated processor port
in the same chassis.
Syntax DellObjectRange
Access Read-only

Cache Device Table

Name cacheDeviceTable
Object ID 1.3.6.1.4.1.674.10892.1.1100.40
Description Defines the Cache Device Table.
Syntax SEQUENCE OF CacheDeviceTableEntry
Access Not accessible

Device Group 283


book.book Page 284 Monday, March 14, 2011 3:01 PM

Cache Device Table Entry

Name cacheDeviceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1
Description Defines the Cache Device Table entry.
Syntax CacheDeviceTableEntry
Access Not accessible
Index cacheDevicechassisIndex, cacheDeviceIndex

Cache Device Chassis Index

Name cacheDevicechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Cache Device Index

Name cacheDeviceIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.2
Description Defines the index of the cache device in this chassis.
Syntax DellObjectRange
Access Read-only

Cache Device State Capabilities

Name cacheDeviceStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.3
Description Defines the capabilities of the cache device.
Syntax DellStateCapabilities
Access Read-only

284 Device Group


book.book Page 285 Monday, March 14, 2011 3:01 PM

Cache Device State Settings

Name cacheDeviceStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.4
Description Defines the state of the cache device.
Syntax DellStateSettings
Access Read-write

Cache Device Status

Name cacheDeviceStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.5
Description Defines the status of the cache device.
Syntax DellStatus
Access Read-only

Cache Device Processor Device Index Reference

Name cacheDeviceprocessorDeviceIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.6
Description Defines the index number of the processor device with which
this cache device is associated.
Syntax DellObjectRange
Access Read-only

Cache Device Type

Name cacheDeviceType
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.7
Description Defines the type of cache device.
Syntax DellCacheDeviceType (See Table 14-7)
Access Read-only

Device Group 285


book.book Page 286 Monday, March 14, 2011 3:01 PM

Cache Device Location

Name cacheDeviceLocation
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.8
Description Defines the location of the cache device.
Syntax DellCacheDeviceLocation (See Table 14-13)
Access Read-only

Cache Device Status State

Name cacheDeviceStatusState
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.9
Description Defines the status state of the cache device.
Syntax DellCacheDeviceStatusState (See Table 14-10)
Access Read-only

Cache Device External Socket Name

Name cacheDeviceExternalSocketName
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.10
Description Defines the external socket name of the cache device, if the
cache is socketed.
Syntax DellString
Access Read-only

Cache Device Level

Name cacheDeviceLevel
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.11
Description Defines the level of the cache device.
Syntax DellCacheDeviceLevel (See Table 14-8)
Access Read-only

286 Device Group


book.book Page 287 Monday, March 14, 2011 3:01 PM

Cache Device Maximum Size

Name cacheDeviceMaximumSize
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.12
Description Defines the maximum size of the cache device in
kilobytes (KB). A zero (0) indicates that the size is unknown.
Syntax DellUnsigned32BitRange
Access Read-only

Cache Device Current Size

Name cacheDeviceCurrentSize
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.13
Description Defines the current size of the cache device in KB. A zero (0)
indicates that the size is unknown.
Syntax DellUnsigned32BitRange
Access Read-only

Cache Device Speed

Name cacheDeviceSpeed
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.14
Description Defines the speed of the cache device in nanoseconds. A zero (0)
indicates that the speed is unknown.
Syntax DellUnsigned32BitRange
Access Read-only

Cache Device Write Policy

Name cacheDeviceWritePolicy
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.15
Description Defines the write policy of the cache device.
Syntax DellCacheDeviceWritePolicy (See Table 14-9)
Access Read-only

Device Group 287


book.book Page 288 Monday, March 14, 2011 3:01 PM

Cache Device Is Socketed

Name cacheDeviceIsSocketed
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.16
Description Defines if the cache device is socketed.
Syntax DellBoolean
Access Read-only

Cache Device Error Checking and Correction (ECC) Type

Name cacheDeviceECCType
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.17
Description Defines the type of error correction in use by the cache device.
Syntax DellCacheDeviceECCType (See Table 14-11)
Access Read-only

Cache Device Associativity

Name cacheDeviceAssociativity
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.18
Description Defines the type of associativity in use by the cache device.
Syntax DellCacheDeviceAssociativity (See Table 14-12)
Access Read-only

Cache Device Supported Type

Name cacheDeviceSupportedType
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.19
Description Defines the type of static random-access memory (SRAM) that
the cache device can support.
Syntax DellCacheDeviceSupportedType
Access Read-only

288 Device Group


book.book Page 289 Monday, March 14, 2011 3:01 PM

Cache Device Current Type

Name cacheDeviceCurrentType
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.20
Description Defines the current type of SRAM for the cache device.
Syntax DellCacheDeviceSRAMType (See Table 14-14)
Access Read-only

Memory Device Table

Name memoryDeviceTable
Object ID 1.3.6.1.4.1.674.10892.1.1100.50
Description Defines the Memory Device Table.
Syntax SEQUENCE OF MemoryDeviceTableEntry
Access Not accessible

Memory Device Table Entry

Name memoryDeviceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1
Description Defines the Memory Device Table entry.
Syntax MemoryDeviceTableEntry
Access Not accessible
Index memoryDevicechassisIndex, memoryDeviceIndex

Memory Device Chassis Index

Name memoryDevicechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Device Group 289


book.book Page 290 Monday, March 14, 2011 3:01 PM

Memory Device Index

Name memoryDeviceIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.2
Description Defines the index of the memory device in this chassis.
Syntax DellObjectRange
Access Read-only

Memory Device State Capabilities

Name memoryDeviceStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.3
Description Defines the capabilities of the memory device.
Syntax DellStateCapabilities
Access Read-only

Memory Device State Settings

Name memoryDeviceStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.4
Description Defines the state of the memory device.
Syntax DellStateSettings
Access Read-write

Memory Device Status

Name memoryDeviceStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.5
Description Defines the status of the memory device.
Syntax DellStatus
Access Read-only

290 Device Group


book.book Page 291 Monday, March 14, 2011 3:01 PM

Memory Device Memory Port Index Reference

Name memoryDeviceMemoryPortIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.6
Description Defines the index of the memory port of which this memory
device is part.
Syntax DellObjectRange
Access Read-only

Memory Device Type

Name memoryDeviceType
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.7
Description Defines the type of the memory device.
Syntax DellMemoryDeviceType (See Table 14-16)
Access Read-only

Memory Device Location Name

Name memoryDeviceLocationName
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.8
Description Defines the location name of the memory device.
Syntax DellString
Access Read-write

Device Group 291


book.book Page 292 Monday, March 14, 2011 3:01 PM

Memory Device Error Count


NOTE: "Memory Device Failure Modes" on page 295 has now replaced this
attribute. Memory Device Error Count should no longer be used. If you use the
Memory Device Error Count attribute, the value returned is always zero, and using
the attribute has no effect.

Name memoryDeviceErrorCount
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.9
Description Defines the total number of Error Checking and Correction (ECC)
errors detected by the memory device. Writing a 0 (zero) to this
variable resets the devices error counts.
Syntax DellSigned32BitRange
Access Read-write

Memory Device Bank Location Name

Name memoryDeviceBankLocationName
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.10
Description Defines the bank location name of the memory device.
Syntax DellString
Access Read-only

Memory Device Type Details

Name memoryDeviceTypeDetails
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.11
Description Defines the detailed type of the memory device.
Syntax DellMemoryDeviceTypeDetails (See Table 13-17)
Access Read-only

292 Device Group


book.book Page 293 Monday, March 14, 2011 3:01 PM

Memory Device Form Factor

Name memoryDeviceFormFactor
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.12
Description Defines the form factor of the memory device.
Syntax DellMemoryDeviceFormFactor (See Table 14-15)
Access Read-only

Memory Device Set

Name memoryDeviceSet
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.13
Description Defines if the memory device is a part of a set. A zero (0)
indicates that this device is not part of a set.
Syntax DellUnsigned32BitRange
Access Read-only

Memory Device Size

Name memoryDeviceSize
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.14
Description Defines the size in KB of the memory device.
Syntax DellUnsigned32BitRange
Access Read-only

Memory Device Speed

Name memoryDeviceSpeed
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.15
Description Defines the speed in nanoseconds of the memory device.
A zero (0) indicates that the speed is unknown.
Syntax DellUnsigned32BitRange
Access Read-only

Device Group 293


book.book Page 294 Monday, March 14, 2011 3:01 PM

Memory Device Total Bus Width

Name memoryDeviceTotalBusWidth
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.16
Description Defines the total number of bits, including ECC, used by the
memory device.
Syntax DellUnsigned32BitRange
Access Read-only

Memory Device Total Data Bus Width

Name memoryDeviceTotalDataBusWidth
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.17
Description Defines the total number of data bits used by the memory
device.
Syntax DellUnsigned32BitRange
Access Read-only

Memory Device Correctable Memory Event Count


NOTE: "Memory Device Failure Modes" on page 295 has now replaced this
attribute. Memory Device Correctable Memory Event Count should no longer be
used. If you use the Memory Device Correctable Memory Event Count attribute, the
value returned is always zero, and using the attribute has no effect.

Name memoryDeviceSingleBitErrorCount
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.18
Description Defines the total number of Correctable Memory Events
detected by the memory device.
Syntax DellSigned32BitRange
Access Read-only

294 Device Group


book.book Page 295 Monday, March 14, 2011 3:01 PM

Memory Device Uncorrectable Memory Event Count


NOTE: "Memory Device Failure Modes" on page 295 has now replaced this
attribute. Memory Device Uncorrectable Memory Event Count should no longer be
used. If you use the Memory Device Uncorrectable Memory Event Count attribute,
the value returned is always zero, and using the attribute has no effect.

Name memoryDeviceMultiBitErrorCount
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.19
Description Defines the total number of Uncorrectable Memory Events
detected by the memory device.
Syntax DellSigned32BitRange
Access Read-only

Memory Device Failure Modes

Name memoryDeviceFailureModes
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.20
Description Defines the failure modes of the memory device when the
memoryDeviceStatus attribute is not OK. It is a bit field that
can be used to report more than one type of failure mode by
using a combination of the defined bit masks.
Syntax DellMemoryDeviceFailureModes
Access Read-only

Memory Device Manufacturer Name

Name memoryDeviceManufacturerName
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.21
Description Defines the manufacturer of the memory device.
Syntax DellString
Access Read-only

Device Group 295


book.book Page 296 Monday, March 14, 2011 3:01 PM

Memory Device Part Number Name

Name memoryDevicePartNumberName
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.22
Description Defines the manufacturer's part number for the memory device.
Syntax DellString
Access Read-only

Memory Device Serial Number Name

Name memoryDeviceSerialNumberName
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.23
Description Defines the serial number of the memory device.
Syntax DellString
Access Read-only

Memory Device Asset Tag Name

Name memoryDeviceAssetTagName
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.24
Description Defines the asset tag of the memory device.
Syntax DellString
Access Read-only

Memory Device Speed Name

Name memoryDeviceSpeedName
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.25
Description This attribute defines the speed of the memory device in string
format with units specified in string.
Syntax DellString
Access Read-only

296 Device Group


book.book Page 297 Monday, March 14, 2011 3:01 PM

Memory Device Mapped Address Table

Name memoryDeviceMappedAddressTable
Object ID 1.3.6.1.4.1.674.10892.1.1100.60
Description Defines the Memory Device Mapped Address Table.
Syntax SEQUENCE OF MemoryDeviceMappedAddressTableEntry
Access Not accessible

Memory Device Mapped Address Table Entry

Name memoryDeviceMappedAddressTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1
Description Defines the Memory Device Mapped Address Table entry.
Syntax MemoryDeviceMappedAddressTableEntry
Access Not accessible
Index memoryDeviceMappedAddresschassisIndex,
memoryDeviceMappedAddressIndex

Memory Device Mapped Address Chassis Index

Name memoryDeviceMappedAddresschassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Device Group 297


book.book Page 298 Monday, March 14, 2011 3:01 PM

Memory Device Mapped Address Index

Name memoryDeviceMappedAddressIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.2
Description Defines the index (one-based) of the memory device mapped
address in this chassis.
Syntax DellObjectRange
Access Read-only

Memory Device Mapped Address State Capabilities

Name memoryDeviceMappedAddressStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.3
Description Defines the capabilities of the memory device mapped address.
Syntax DellStateCapabilities
Access Read-only

Memory Device Mapped Address State Settings

Name memoryDeviceMappedAddressStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.4
Description Defines the state of the memory device mapped address.
Syntax DellStateSettings
Access Read-write

Memory Device Mapped Address Status

Name memoryDeviceMappedAddressStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.5
Description Defines the status of the memory device mapped address.
Syntax DellStatus
Access Read-only

298 Device Group


book.book Page 299 Monday, March 14, 2011 3:01 PM

Memory Device Index Reference

Name memoryDeviceIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6
Description Defines the index of the memory device(s) associated with this
memory device mapped address.
Syntax DellObjectRange
Access Read-only

Memory Device Mapped Address Row Position

Name memoryDeviceMappedAddressRowPosition
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.7
Description Defines the position of the referenced memory in a row of the
memory device mapped address.
Syntax DellUnsigned32BitRange
Access Read-only

Memory Device Mapped Address Interleave Position

Name memoryDeviceMappedAddressInterleavePosition
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.8
Description Defines the position of the referenced memory in an interleave
of the memory device mapped address.
Syntax DellUnsigned32BitRange
Access Read-only

Device Group 299


book.book Page 300 Monday, March 14, 2011 3:01 PM

Memory Device Mapped Address Interleave Depth

Name memoryDeviceMappedAddressInterleaveDepth
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.9
Description Defines the maximum number of consecutive rows from the
referenced memory device that are accessed in a single
interleaved transfer in the memory device mapped address.
Syntax DellUnsigned32BitRange
Access Read-only

Memory Device Mapped Address Starting Address

Name memoryDeviceMappedAddressStartingAddress
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.10
Description Defines the physical starting address in KB of the memory
device mapped address.
Syntax DellUnsigned64BitRange
Access Read-only

Memory Device Mapped Address Ending Address

Name memoryDeviceMappedAddressEndingAddress
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.11
Description Defines the physical ending address in KB of the memory device
mapped address.
Syntax DellUnsigned64BitRange
Access Read-only

Generic Device Table

Name genericDeviceTable
Object ID 1.3.6.1.4.1.674.10892.1.1100.70
Description Defines the Generic Device Table.
Syntax SEQUENCE OF GenericDeviceTableEntry
Access Not accessible

300 Device Group


book.book Page 301 Monday, March 14, 2011 3:01 PM

Generic Device Table Entry

Name genericDeviceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1
Description Defines the Generic Device Table entry.
Syntax GenericDeviceTableEntry
Access Not accessible
Index genericDevicechassisIndex, genericDeviceIndex

Generic Device Chassis Index

Name genericDevicechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Generic Device Index

Name genericDeviceIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.2
Description Defines the index of the generic device in this chassis.
Syntax DellObjectRange
Access Read-only

Generic Device State Capabilities

Name genericDeviceStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.3
Description Defines the capabilities of the generic device.
Syntax DellStateCapabilities
Access Read-only

Device Group 301


book.book Page 302 Monday, March 14, 2011 3:01 PM

Generic Device State Settings

Name genericDeviceStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.4
Description Defines the state of the generic device.
Syntax DellStateSettings
Access Read-write

Generic Device Status

Name genericDeviceStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.5
Description Defines the status of the generic device.
Syntax DellStatus
Access Read-only

Generic Device System Slot Index Reference

Name genericDeviceSystemSlotIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.6
Description Defines the index of the system slot into which this generic
device is plugged.
Syntax DellObjectRange
Access Read-only

Generic Device Type

Name genericDeviceType
Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.7
Description Defines the type of the generic device.
Syntax DellGenericDeviceType (See Table 14-18)
Access Read-only

302 Device Group


book.book Page 303 Monday, March 14, 2011 3:01 PM

Generic Device Name

Name genericDeviceName
Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.8
Description Defines the name of the generic device.
Syntax DellString
Access Read-only

PCI Device Table

Name pCIDeviceTable
Object ID 1.3.6.1.4.1.674.10892.1.1100.80
Description Defines the PCI Device Detail Table.
Syntax SEQUENCE OF PCIDeviceTableEntry
Access Not accessible

PCI Device Table Entry

Name pCIDeviceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1
Description Defines the PCI Device Table entry.
Syntax Not accessible
Access PCIDeviceTableEntry
Index pCIDevicechassisIndex, pCIDeviceIndex

PCI Device Chassis Index

Name pCIDevicechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.1
Description Defines the index (one-based) of this chassis.
Syntax Read-only
Access DellObjectRange

Device Group 303


book.book Page 304 Monday, March 14, 2011 3:01 PM

PCI Device Index

Name pCIDeviceIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.2
Description Defines the index (one-based) of the PCI device in this chassis.
Syntax DellObjectRange
Access Read-only

PCI Device State Capabilities

Name pCIDeviceStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.3
Description Defines the capabilities of the PCI device.
Syntax DellStateCapabilities
Access Read-only

PCI Device State Settings

Name pCIDeviceStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.4
Description Defines the state of the PCI device.
Syntax DellStateSettings
Access Read-write

PCI Device Status

Name pCIDeviceStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.5
Description Defines the status of the PCI device.
Syntax DellStatus
Access Read-only

304 Device Group


book.book Page 305 Monday, March 14, 2011 3:01 PM

PCI Device System Slot Index Reference

Name pCIDeviceSystemSlotIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.6
Description Defines the index number of the system slot that this PCI
device is in.
Syntax DellObjectRange
Access Read-only

PCI Device Data Bus Width

Name pCIDeviceDataBusWidth
Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.7
Description Defines the bus width of the PCI device in this chassis.
Syntax DellUnsigned32BitRange
Access Read-only

PCI Device Manufacturer Name

Name pCIDeviceManufacturerName
Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.8
Description Defines the name of the PCI device manufacturer.
Syntax DellString
Access Read-only

PCI Device Description Name

Name pCIDeviceDescriptionName
Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.9
Description Defines the descriptive name of the PCI device.
Syntax DellString
Access Read-only

Device Group 305


book.book Page 306 Monday, March 14, 2011 3:01 PM

PCI Device Speed

Name pCIDeviceSpeed
Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.10
Description Defines the bus speed in MHz of the PCI device in this chassis.
A zero (0) indicates that the speed is unknown.
Syntax DellUnsigned32BitRange
Access Read-only

PCI Device Adapter Fault

Name pCIDeviceAdapterFault
Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.11
Description Defines whether the PCI device in this chassis has detected a fault.
Syntax DellBoolean
Access Read-only

PCI Device Configuration Space Table

Name pCIDeviceConfigurationSpaceTable
Object ID 1.3.6.1.4.1.674.10892.1.1100.82
Description Defines the PCI Device Configuration Table.
Syntax SEQUENCE OF PCIDeviceConfigurationSpaceTableEntry
Access Not accessible

PCI Device Configuration Space Table Entry

Name pCIDeviceConfigurationSpaceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1
Description Defines the PCI Device Configuration Table entry.
Syntax PCIDeviceConfigurationSpaceTableEntry
Access Not accessible
Index pCIDeviceConfigurationSpacechassisIndex,
pCIDeviceConfigurationSpaceIndex

306 Device Group


book.book Page 307 Monday, March 14, 2011 3:01 PM

PCI Device Configuration Space Chassis Index

Name pCIDeviceConfigurationSpacechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

PCI Device Configuration Space Index

Name pCIDeviceConfigurationSpaceIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.2
Description Defines the index (one-based) of the PCI device configuration
in this chassis.
Syntax DellObjectRange
Access Read-only

PCI Device Configuration Space State Capabilities

Name pCIDeviceConfigurationSpaceStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.3
Description Defines the capabilities of the PCI device configuration.
Syntax DellStateCapabilities
Access Read-only

PCI Device Configuration Space State Settings

Name pCIDeviceConfigurationSpaceStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.4
Description Defines the state of the PCI device configuration.
Syntax DellStateSettings
Access Read-write

Device Group 307


book.book Page 308 Monday, March 14, 2011 3:01 PM

PCI Device Configuration Space Status

Name pCIDeviceConfigurationSpaceStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.5
Description Defines the status of the PCI device configuration.
Syntax DellStatus
Access Read-only

PCI Device Index Reference

Name pCIDeviceIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.6
Description Defines the index number of PCI device that this configuration
applies to.
Syntax DellObjectRange
Access Read-only

PCI Device Configuration Space Bus Number

Name pCIDeviceConfigurationSpaceBusNumber
Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.7
Description Defines the bus number of the PCI device configuration in this
chassis.
Syntax DellUnsigned32BitRange
Access Read-only

PCI Device Configuration Space Device Number

Name pCIDeviceConfigurationSpaceDeviceNumber
Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.8
Description Defines the device number of the PCI device in this chassis.
Syntax DellUnsigned32BitRange
Access Read-only

308 Device Group


book.book Page 309 Monday, March 14, 2011 3:01 PM

PCI Device Configuration Space Function Number

Name pCIDeviceConfigurationSpaceFunctionNumber
Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.9
Description Defines the function number of the PCI device in this chassis.
Syntax DellUnsigned32BitRange
Access Read-only

PCI Device Configuration Space Header

Name pCIDeviceConfigurationSpaceHeader
Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.10
Description Defines the common configuration space header of the PCI device.
Syntax Octet String (SIZE(0..1025))
Access Read-only

Network Device Table

Name networkDeviceTable
Object ID 1.3.6.1.4.1.674.10892.1.1100.90
Description Defines the Network Device Table.
Syntax SEQUENCE OF NetworkDeviceTableEntry
Access Not accessible

Network Device Table Entry

Name networkDeviceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1
Description Defines the Network Device Table Entry.
Syntax NetworkDeviceTableEntry
Access Not accessible
Index networkDeviceChassisIndex, networkDeviceIndex

Device Group 309


book.book Page 310 Monday, March 14, 2011 3:01 PM

Network Device Chassis Index

Name networkDeviceChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.1
Description Defines the index (one-based) of the chassis that contains the
network device.
Syntax DellObjectRange
Access Read-only

Network Device Index

Name networkDeviceIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.2
Description Defines the index (one-based) of the network device.
Syntax DellObjectRange
Access Read-only

Network Device Status

Name networkDeviceStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.3
Description Defines the status of the network device.
Syntax DellStatus
Access Read-only

Network Device Connection Status

Name networkDeviceConnectionStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.4
Description Defines the connection status of the network device.
Syntax DellNetworkDeviceConnectionStatus (see Table 14-20)
Access Read-only

310 Device Group


book.book Page 311 Monday, March 14, 2011 3:01 PM

Network Device Description Name

Name networkDeviceDescriptionName
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.5
Description Defines the description of the network device.
Syntax DellString
Access Read-only

Network Device Product Name

Name networkDeviceProductName
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.6
Description Defines the product name of the network device.
Syntax DellString
Access Read-only

Network Device Vendor Name

Name networkDeviceVendorName
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.7
Description Defines the name of the vendor of the network device.
Syntax DellString
Access Read-only

Network Device Service Name

Name networkDeviceServiceName
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.8
Description Defines the service name of the network device.
Syntax DellString
Access Read-only

Device Group 311


book.book Page 312 Monday, March 14, 2011 3:01 PM

Network Device Driver Image Path Name

Name networkDeviceDriverImagePathName
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.9
Description Defines the path to the binary image of the driver for the
network device.
Syntax DellString
Access Read-only

Network Device Driver Version Name

Name networkDeviceDriverVersionName
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.10
Description Defines the version of the driver for the network device.
Syntax DellString
Access Read-only

Network Device IP Address

Name networkDeviceIPAddress
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.11
Description Defines the IP address of the network device.
Syntax IpAddress
Access Read-only

Network Device IP Subnet Mask

Name networkDeviceIPSubnetMask
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.12
Description Defines the IP subnet mask for the IP address currently assigned
to the network device.
Syntax IpAddress
Access Read-only

312 Device Group


book.book Page 313 Monday, March 14, 2011 3:01 PM

Network Device Default Gateway IP Address

Name networkDeviceDefaultGatewayIPAddress
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.13
Description Defines the IP address of the default gateway for the network device.
Syntax IpAddress
Access Read-only

Network Device DHCP Server IP Address

Name networkDeviceDHCPServerIPAddress
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.14
Description Defines the IP address of the DHCP server that was used to
obtain the IP address of the network device if DHCP was used
to configure the network device.
Syntax IpAddress
Access Read-only

Network Device Current MAC Address

Name networkDeviceCurrentMACAddress
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.15
Description Defines the current MAC address of the network device.
Syntax DellMACAddress
Access Read-only

Network Device Permanent MAC Address

Name networkDevicePermanentMACAddress
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.16
Description Defines the permanent MAC address of the network device.
Syntax DellMACAddress
Access Read-only

Device Group 313


book.book Page 314 Monday, March 14, 2011 3:01 PM

Network Device PCI Bus Number

Name networkDevicePCIBusNumber
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.17
Description Defines the PCI bus number of the network device.
Syntax DellUnsigned8BitRange
Access Read-only

Network Device PCI Device Number

Name networkDevicePCIDeviceNumber
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.18
Description Defines the PCI device number of the network device.
Syntax DellUnsigned8BitRange
Access Read-only

Network Device PCI Function Number

Name networkDevicePCIFunctionNumber
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.19
Description Defines the PCI function number of the network device.
Syntax DellUnsigned8BitRange
Access Read-only

Network Device IRQ

Name networkDeviceIRQ
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.20
Description Defines the interrupt request number of the network device.
Syntax DellUnsigned32BitRange
Access Read-only

314 Device Group


book.book Page 315 Monday, March 14, 2011 3:01 PM

Network Device Base IO Port Address

Name networkDeviceBaseIOPortAddress
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.21
Description Defines the base input/outport port address of the network device.
Syntax DellUnsigned32BitRange
Access Read-only

Network Device Teaming Flags

Name networkDeviceTeamingFlags
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.22
Description Defines the teaming features of the network device.
Syntax DellNetworkDeviceTeamingFlags (see Table 14-21)
Access Read-only

Network Device TOE Capability Flags

Name networkDeviceTOECapabilityFlags
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.23
Description Defines the TCP/IP Offload Engine (TOE) capability flags of
the network device.
Syntax DellNetworkDeviceTOECapabilityFlags (see Table 14-22)
Access Read-only

Network Device TOE Enabled

Name networkDeviceTOEEnabled
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.24
Description Defines if TOE is enabled for the network device.
Syntax DellBoolean
Access Read-only

Device Group 315


book.book Page 316 Monday, March 14, 2011 3:01 PM

Network Device RDMA Capability Flags

Name networkDeviceRDMACapabilityFlags
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.25
Description Defines the Remote Direct Memory Access (RDMA) capability
flags of the network device.
Syntax DellNetworkDeviceRDMACapabilityFlags (see Table 14-23)
Access Read-only

Network Device RDMA Enabled

Name networkDeviceRDMAEnabled
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.26
Description Defines if RDMA is enabled for the network device.
Syntax DellBoolean
Access Read-only

Network Device iSCSI Capability Flags

Name networkDeviceiSCSICapabilityFlags
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.27
Description Defines the Internet Small Computer System Interface (iSCSI)
capability flags of the network device.
Syntax DellNetworkDeviceiSCSICapabilityFlags (see Table 14-24)
Access Read-only

Network Device iSCSI Enabled

Name networkDeviceiSCSIEnabled
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.28
Description Defines if iSCSI is enabled for the network device.
Syntax DellBoolean
Access Read-only

316 Device Group


book.book Page 317 Monday, March 14, 2011 3:01 PM

Managed System Services Device Table

Name managedSystemServicesDeviceTable
Object ID 1.3.6.1.4.1.674.10892.1.1100.100
Description Defines the Managed System Services Device Table.
Syntax Sequence of ManagedSystemServicesDeviceTable
Access Not accessible

Managed System Services Device Table Entry

Name managedSystemServicesDeviceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1
Description Defines the managed system services device table entry.
Syntax ManagedSystemServicesDeviceTableEntry
Access Not accessible
Index managedSystemServicesDeviceChassisIndex,
managedSystemServicesDeviceIndex

Managed System Services Device Chassis Index

Name managedSystemServicesDeviceChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.1
Description Defines the index (one-based) of the chassis that contains the
managed system services device.
Syntax DellObjectRange
Access Read-only

Device Group 317


book.book Page 318 Monday, March 14, 2011 3:01 PM

Managed System Services Device Index

Name managedSystemServicesDeviceIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.2
Description Defines the index (one-based) of the managed system services
device.
Syntax DellObjectRange
Access Read-only

Managed System Services Device Status

Name managedSystemServicesDeviceStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.3
Description Defines the status of the managed system services device.
Syntax DellStatus
Access Read-only

Managed System Services Device Type

Name managedSystemServicesDeviceType
Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.4
Description Defines the type of the managed system services device.
Syntax DellManagedSystemServicesDeviceType. See Table 14-25
Access Read-only

318 Device Group


book.book Page 319 Monday, March 14, 2011 3:01 PM

Managed System Services Device Storage Present

Name managedSystemServicesDeviceStoragePresent
Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.5
Description Defines whether storage is present on the managed system
services device.
Syntax DellBoolean
Access Read-only

Managed System Services Device Storage Size

Name managedSystemServicesDeviceStorageSize
Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.6
Description Defines the size in Megabytes (MB) of the storage present on
the managed system services device.
Syntax DellUnsigned32BitRange
Access Read-only

SD Card Unit Table

Name sdCardUnitTable
Object ID 1.3.6.1.4.1.674.10892.1.1100.110
Description Defines the SD Card Unit Table.
Syntax SEQUENCE OF SdCardUnitTableEntry
Access Not accessible

SD Card Unit Table Entry

Name sdCardUnitTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1
Description Defines the SD Card Unit Table Entry.
Syntax SdCardUnitTableEntry
Access Not accessible

Device Group 319


book.book Page 320 Monday, March 14, 2011 3:01 PM

Name sdCardUnitTableEntry
Index sdCardUnitChassisIndex,
sdCardUnitIndex

SD Card Unit Chassis Index

Name sdCardUnitChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.1
Description Defines the index (one-based) of the chassis that contains the
SD Card unit.
Syntax DellObjectRange
Access Read-only

SD Card Unit Index

Name sdCardUnitIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.2
Description Defines the index (one-based) of the SD Card unit.
Syntax DellObjectRange
Access Read-only

SD Card Unit State Capabilities

Name sdCardUnitStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.3
Description Defines the state capabilities of the SD Card unit.
Syntax DellStateCapabilities
Access Read-only

SD Card Unit State Settings

Name sdCardUnitStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.4

320 Device Group


book.book Page 321 Monday, March 14, 2011 3:01 PM

Name sdCardUnitStateSettings
Description Defines the state settings of the SD Card unit.
Syntax DellStateSettings
Access Read-only

SD Card Unit Redundancy Status

Name sdCardUnitRedundancyStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.5
Description Defines the redundancy status of the SD Card unit.
Syntax DellStatusRedundancy
Access Read-only

SD Card Unit Count For Redundancy

Name sdCardUnitCountForRedundancy
Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.6
Description Defines the total number of SD Card devices required for this
SD Card unit to have full redundancy.
Syntax DellObjectRange
Access Read-only

SD Card Unit Name

Name sdCardUnitName
Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.7
Description Defines the name of the SD Card unit.
Syntax DellString
Access Read-only

Device Group 321


book.book Page 322 Monday, March 14, 2011 3:01 PM

SD Card Unit Status

Name sdCardUnitStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.8
Description Defines the status of the SD Card unit.
Syntax DellStatus
Access Read-only

SD Card Device Table

Name sdCardDeviceTable
Object ID 1.3.6.1.4.1.674.10892.1.1100.112
Description Defines the SD Card Device Table.
Syntax SEQUENCE OF SdCardDeviceTableEntry
Access Not accessible

SD Card Device Table Entry

Name sdCardDeviceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1
Description Defines the SD Card Device Table Entry.
Syntax SdCardDeviceTableEntry
Access Not accessible
Index sdCardDeviceChassisIndex,
sdCardDeviceIndex

SD Card Device Chassis Index

Name sdCardDeviceChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.1
Description Defines the index (one-based) of the chassis that contains the
SD Card device.
Syntax DellObjectRange

322 Device Group


book.book Page 323 Monday, March 14, 2011 3:01 PM

Name sdCardDeviceChassisIndex
Access Read-only

SD Card Device Index

Name sdCardDeviceIndex
Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.2
Description Defines the index (one-based) of the SD Card device.
Syntax DellObjectRange
Access Read-only

SD Card Device Status

Name sdCardDeviceStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.3
Description Defines the status of the SD Card device.
Syntax DellStatus
Access Read-only

SD Card Device Type

Name sdCardDeviceType
Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.4
Description Defines the type of the SD Card device.
Syntax DellSDCardDeviceType
Access Read-only

SD Card Device Config Capabilities

Name sdCardDeviceConfigCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.5
Description Defines the configuration capabilities of the SD Card device.
Syntax DellSDCardDeviceConfigCapabilities

Device Group 323


book.book Page 324 Monday, March 14, 2011 3:01 PM

Name sdCardDeviceConfigCapabilities
Access Read-only

SD Card Device Config Settings

Name sdCardDeviceConfigSettings
Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.6
Description Defines the configuration settings of the SD Card device.
Syntax DellSDCardDeviceConfigSettings
Access Read-only

SD Card Device Location Name

Name sdCardDeviceLocationName
Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.7
Description Defines the location of the SD Card device.
Syntax DellString
Access Read-only

SD Card Device Card Present

Name sdCardDeviceCardPresent
Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.8
Description Defines whether the SD Card is present for the SD Card device.
Syntax DellBoolean
Access Read-only

SD Card Device Card State

Name sdCardDeviceCardState
Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.9
Description Defines the state of the SD Card.
Syntax DellSDCardDeviceCardState

324 Device Group


book.book Page 325 Monday, March 14, 2011 3:01 PM

Name sdCardDeviceCardState
Access Read-only

SD Card Device Card Storage Size

Name sdCardDeviceCardStorageSize
Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.10
Description Defines the storage size in MB (megabytes) of the SD card for
the SD Card device.
Syntax DellUnsigned32BitRange
Access Read-only

SD Card Device Unit Index Reference

Name sdCardDeviceUnitIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.11
Description Defines the index to the associated SD Card unit if the SD Card
device is part of a SD Card unit.
Syntax DellObjectRange
Access Read-only

Device Group 325


book.book Page 326 Monday, March 14, 2011 3:01 PM

SD Card Device Card Available Storage Size

Name sdCardDeviceCardAvailableStorageSize
Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.12
Description Defines the available storage size in MB (megabytes) of the SD
card for the SD card device.
Syntax DellSigned32BitRange
Access Read-only

SD Card Device Card Licensed

Name sdCardDeviceCardLicensed
Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.13
Description Defines whether the SD card is licensed by the system vendor.
Syntax DellSDCardDeviceCardLicensed
Access Read-only

Device Group Variable Values


This section includes definitions for server administrator-specific variable
values used in this section.

Table 14-1. Pointing Device Type

Variable Name: DellPointingDeviceType


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceTypeIsOther(1) Device type is not one of the following:
deviceTypeIsUnknown(2) Device type is unknown.
deviceTypeIsAMouse(3) Device type is a mouse.
deviceTypeIsATrackBall(4) Device type is a track ball.
deviceTypeIsATrackPoint(5) Device type is a track point.
deviceTypeIsAGlidePoint(6) Device type is a glide point.

326 Device Group


book.book Page 327 Monday, March 14, 2011 3:01 PM

Table 14-1. Pointing Device Type (continued)

Variable Name: DellPointingDeviceType


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceTypeIsATouchPad(7) Device type is a touch pad.

Table 14-2. Processor Device Status State

Variable Name: DellProcessorDeviceStatusState


Data Type: Integer
Possible Data Values Meaning of Data Value
other(1) Processor device type is not one of the
following:
unknown(2) Device type is unknown.
enabled(3) Device is enabled.
userDisabled(4) Device is disabled by the user.
biosDisabled(5) Device has its BIOS disabled.
idle(6) Device is idle.

Table 14-3. Processor Device Status Reading

Variable Name: DellProcessorDeviceStatusReading


Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
internalError(1) The processor experienced an internal
error
thermalTrip(2) The processor experienced a thermal trip
configurationError(32) The processor experienced a configuration
error
processorPresent(128) The processor is present

Device Group 327


book.book Page 328 Monday, March 14, 2011 3:01 PM

Table 14-3. Processor Device Status Reading (continued)

Variable Name: DellProcessorDeviceStatusReading


Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
processorDisabled(256) The processor is disabled
terminatorPresent(512) The terminator is Present
processorThrottled(1024) The processor is throttled

Table 14-4. Processor Device Type

Variable Name: DellProcessorDeviceType


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceTypeIsOther(1) The processor device type is not one
of the following values:
deviceTypeIsUnknown(2) The processor device type is
unknown.
deviceTypeIsCPU(3) The processor device type is a central
processing unit.
deviceTypeIsMathProcessor(4) The processor device type is a math
processor.
deviceTypeIsDSP(5) The processor device type is a digital
signal processor.
deviceTypeIsAVideoProcessor(6) The processor device is a video
processor.

328 Device Group


book.book Page 329 Monday, March 14, 2011 3:01 PM

Table 14-5. Processor Upgrade Information

Variable Name: DellProcessorUpgradeInformation


Data Type: Integer
Possible Data Values Meaning of Data Value
processorUpgradeIsOther(1) The upgrade device type is
not one of the following:
processorUpgradeIsUnknown(2) Upgrade device type is
unknown.
processorUpgradeIsByDaughterBoard(3) Upgrade device is on a
daughter board.
processorUpgradeIsByZIFSocket(4) Upgrade device is in a zero
insertion force (ZIF) socket.
processorUpgradeIsByReplacement(5) Upgrade device is a
replacement.
processorUpgradeIsNone(6) There is no upgrade device.
processorUpgradeIsByLIFSocket(7) Upgrade device is in a low
insertion force (LIF) socket.
processorUpgradeIsBySlot1(8) Upgrade device is a SLOT 1
processor.
processorUpgradeIsBySlot2(9) Upgrade device is a SLOT 2
processor.
processorUpgradeIsBy370PinSocket(10) Upgrade device is a 370 pin
socket.
processorUpgradeIsBySlotA(11) Upgrade is by Slot A.
processorUpgradeIsBySlotM(12) Upgrade is by Slot M.
processorUpgradeIsByScoket423(13) Upgrade is by Socket 423.
processorUpgradeIsBySocketA(14) Upgrade is by Socket A
(Socket 462).
processorUpgradeIsBySocket478(15) Upgrade is by Socket 478.
processorUpgradeIsBySocket754(16) Upgrade is by Socket 754.
processorUpgradeIsBySocket940(17) Upgrade is by Socket 940.

Device Group 329


book.book Page 330 Monday, March 14, 2011 3:01 PM

Table 14-5. Processor Upgrade Information (continued)

Variable Name: DellProcessorUpgradeInformation


Data Type: Integer
Possible Data Values Meaning of Data Value
processorUpgradeIsBySocket939(18) Upgrade is by Socket 939.
processorUpgradeIsBySocketmPGA604(19) Upgrade is by Socket
mPGA604.
processorUpgradeIsBySocketLGA771(20) Upgrade is by Socket
LGA771.
processorUpgradeIsBySocketLGA775(21) Upgrade is by Socket
LGA775.
processorUpgradeIsBySocketS1(22) Upgrade is by Socket S1.
processorUpgradeIsBySocketAM2(23) Upgrade is by Socket AM2.
processorUpgradeIsBySocketF(24) Upgrade is by Socket F
(1207).
processorUpgradeIsBySocketLGA1366(25) Upgrade is by Socket
LGA1366.

Table 14-6. Processor Device Family

Variable Name: DellProcessorDeviceFamily


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceFamilyIsOther(1) The processor family is not one of the
following values.
deviceFamilyIsUnknown(2) The processor family is unknown.
deviceFamilyIs8086(3) The processor family is 8086.
deviceFamilyIs80286(4) The processor family is 80286.
deviceFamilyIs80386(5) The processor family is 80386.
deviceFamilyIs80486(6) The processor family is 80486.
deviceFamilyIS8087(7) The processor family is 8087.

330 Device Group


book.book Page 331 Monday, March 14, 2011 3:01 PM

Table 14-6. Processor Device Family (continued)

Variable Name: DellProcessorDeviceFamily


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceFamilyIs80287(8) The processor family is 80287.
deviceFamilyIs80387(9) The processor family is 80387.
deviceFamilyIs80487(10) The processor family is 80487.
deviceFamilyIsPentium(11) The processor family is Intel Pentium.
deviceFamilyIsPentiumPro(12) The processor family is Pentium Pro.
deviceFamilyIsPentium2(13) The processor family is Pentium II.
deviceFamilyIsPentiumMMX(14) The processor family is Pentium MMX.
deviceFamilyIsCeleron(15) The processor family is Celeron.
deviceFamilyIsXeon(16) The processor family is Xeon.
deviceFamilyIsPentium3(17) The processor family is Pentium III.
deviceFamilyIsPentium3Xeon(18) The processor family is Pentium III
Xeon.
deviceFamilyIsPentium3Step(19) The processor family is Pentium III
Speed Step.
deviceFamilyIsPentiumItanium The processor family is Itanium.
(20)
deviceFamilyIsIntelXeon(21) The processor family is Intel Xeon.
deviceFamilyIsPentium4(22) The processor family is Pentium 4.
deviceFamilyIsIntelXeonMP(23) The processor family is Intel Xeon MP.
deviceFamilyIsIntelItanium2(24) The processor family is Intel Itanium 2.
deviceFamilyIsK5(25) The processor family is K5.
deviceFamilyIsK6(26) The processor family is K6.
deviceFamilyIsK6-2(27) The processor family is K6-2.
deviceFamilyIsK6-3(28) The processor family is K6-3.
deviceFamilyIsAMDAthlon(29) The processor family is AMD Athlon.
deviceFamilyIsAMD2900(30) The processor family is AMD2900.

Device Group 331


book.book Page 332 Monday, March 14, 2011 3:01 PM

Table 14-6. Processor Device Family (continued)

Variable Name: DellProcessorDeviceFamily


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceFamilyIsK6-2Plus(31) The processor family is K6-2+.
deviceFamilyIsPowerPC(32) The processor family is Power PC.
deviceFamilyIsPowerPC601(33) The processor family is Power PC 601.
deviceFamilyIsPowerPC603(34) The processor family is Power PC 603.
deviceFamilyIsPowerPC603Plus The processor family is Power PC
(35) 603+.
deviceFamilyIsPowerPC604(36) The processor family is Power PC 604.
deviceFamilyIsPowerPC620(37) The processor family is Power PC 620.
deviceFamilyIsPowerPCx704(38) The processor family is Power PC x704.
deviceFamilyIsPowerPC750(39) The processor family is Power PC 750.
deviceFamilyIsIntelCoreDuo(40) The processor family is Intel Core Duo.
deviceFamilyIsIntelCoreDuoMobi The processor family is Intel Core Duo
le(41) mobile.
deviceFamilyIsIntelCoreSoloMob The processor family is Intel Core Solo
ile(42) mobile.
deviceFamilyIsIntelAtom(43) The processor family is Intel Atom.
deviceFamilyIsAlpha(48) The processor family is Alpha.
deviceFamilyIsAlpha21064(49) The processor family is Alpha 21064.
deviceFamilyIsAlpha21066(50) The processor family is Alpha 21066.
deviceFamilyIsAlpha21164(51) The processor family is Alpha 21164.
deviceFamilyIsAlpha21164PC(52) The processor family is Alpha
21164PC.
deviceFamilyIsAlpha21164a(53) The processor family is Alpha 21164a.
deviceFamilyIsAlpha21264(54) The processor family is Alpha 21264.
deviceFamilyIsAlpha21364(55) The processor family is Alpha 21364.

332 Device Group


book.book Page 333 Monday, March 14, 2011 3:01 PM

Table 14-6. Processor Device Family (continued)

Variable Name: DellProcessorDeviceFamily


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceFamilyIsAMDTurionIIUltra The processor family is AMD Turion II
DualMobileM(56) Ultra Dual-Core Mobile M Processor
Family.
deviceFamilyIsAMDTurionIIDualM The processor family is AMD Turion II
obileM(57) Dual-Core Mobile M Processor Family.
deviceFamilyIsAMDAthlonIIDualM The processor family is AMD Athlon II
obileM(58) Dual-Core Mobile M Processor Family.
deviceFamilyIsAMDOpteron6100 The processor family is AMD Opteron
(59) 6100 Series Processor.
deviceFamilyIsAMDOpteron4100 The processor family is AMD Opteron
(60) 4100 Series Processor.
deviceFamilyIsAMDOpteron6200 The processor family is AMD Opteron
(61) 6200 Series Processor.
deviceFamilyIsAMDOpteron4200 The processor family is AMD Opteron
(62) 4200 Series Processor.
deviceFamilyIsMIPS(64) The processor family is MIPS.
deviceFamilyIsMIPSR4000(65) The processor family is MIPS R4000.
deviceFamilyIsMIPSR4200(66) The processor family is MIPS R4200.
deviceFamilyIsMIPSR4400(67) The processor family is MIPS R4400.
deviceFamilyIsMIPSR4600(68) The processor family is MIPS R4600.
deviceFamilyIsMIPSR10000(69) The processor family is MIPS R10000.
deviceFamilyIsSPARC(80) The processor family is SPARC.
deviceFamilyIsSuperSPARC(81) The processor family is SuperSPARC.
deviceFamilyIsmicroSPARCII(82) The processor family is microSPARC II.
deviceFamilyIsmicroSPARCIIep The processor family is microSPARC
(83) IIep.
deviceFamilyIsUltraSPARC(84) The processor family is UltraSPARC.
deviceFamilyIsUltraSPARCII(85) The processor family is UltraSPARC II.

Device Group 333


book.book Page 334 Monday, March 14, 2011 3:01 PM

Table 14-6. Processor Device Family (continued)

Variable Name: DellProcessorDeviceFamily


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceFamilyIsUltraSPARCIIi(86) The processor family is UltraSPARC IIi.
deviceFamilyIsUltraSPARCIII(87) The processor family is UltraSPARC
III.
deviceFamilyIsUltraSPARCIIIi The processor family is UltraSPARC
(88) IIIi.
deviceFamilyIs68040(96) The processor family is 68040 Family.
deviceFamilyIs68xxx(97) The processor family is 68xxx.
deviceFamilyIs68000(98) The processor family is 68000.
deviceFamilyIs68010(99) The processor family is 68010.
deviceFamilyIs68020(100) The processor family is 68020.
deviceFamilyIs68030(101) The processor family is 68030.
deviceFamilyIsHobbit(112) The processor family is Hobbit.
deviceFamilyIsCrusoe5000(120) The processor family is Crusoe 5000.
deviceFamilyIsCrusoe3000(121) The processor family is Crusoe 3000.
deviceFamilyIsEfficeon8000 The processor family is Efficeon 8000.
(122)
deviceFamilyIsWeitek(128) The processor family is Weitek.
deviceFamilyIsIntelCeleronM(13 The processor family is Intel Celeron
0) M.
deviceFamilyIsAMDAthlon64(131) The processor family is AMD Athlon
64.
deviceFamilyIsAMDOpteron(132) The processor family is AMD Opteron.
deviceFamilyIsAMDSempron(133) The processor family is AMD Sempron.
deviceFamilyIsAMDTurion64Mobile The processor family is AMD Turion 64
(134) Mobile Technology.
deviceFamilyIsDualCoreAMDOpter The processor family is Dual-Core
on(135) AMD Opteron.

334 Device Group


book.book Page 335 Monday, March 14, 2011 3:01 PM

Table 14-6. Processor Device Family (continued)

Variable Name: DellProcessorDeviceFamily


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceFamilyIsAMDAthlon64X2Dual The processor family is AMD Athlon
Core(136) 64 X2 Dual-Core.
deviceFamilyIsAMDTurion64X2Mob The processor family is AMD Turion 64
ile(137) X2 Mobile Technology.
deviceFamilyIsQuadCoreAMDOpter The processor family is Quad-Core
on(138) AMD Opteron.
deviceFamilyIsThirdGeneration The processor family is third-
AMDOpteron(139) generation AMD Opteron.
deviceFamilyIsAMDPhenomFXQuadC The processor family is AMD Phenom
ore(140) FX Quad-Core.
deviceFamilyIsAMDPhenomX4QuadC The processor family is AMD Phenom
ore(141) X4 Quad-Core.
deviceFamilyIsAMDPhenomX2DualC The processor family is AMD Phenom
ore(142) X2 Dual-Core.
deviceFamilyIsAMDAthlonX2DualC The processor family is AMD Athlon
ore(143) X2 Dual-Core.
deviceFamilyIsPA-RISC(144) The processor family is PA-RISC.
deviceFamilyIsPA-RISC8500(145) The processor family is PA-RISC 8500.
deviceFamilyIsPA-RISC8000(146) The processor family is PA-RISC 8000.
deviceFamilyIsPA- The processor family is PA-RISC
RISC7300LC(147) 7300LC.
deviceFamilyIsPA-RISC7200(148) The processor family is PA-RISC 7200.
deviceFamilyIsPA- The processor family is PA-RISC
RISC7100LC(149) 7100LC.
deviceFamilyIsPA-RISC7100(150) The processor family is PA-RISC 7100.
deviceFamilyIsV30(160) The processor family is V30.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n3200(161) Intel Xeon processor 3200 Series.

Device Group 335


book.book Page 336 Monday, March 14, 2011 3:01 PM

Table 14-6. Processor Device Family (continued)

Variable Name: DellProcessorDeviceFamily


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n3000(162) Xeon processor 3000 Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n5300(163) Intel Xeon processor 5300 Series.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n5100(164) Xeon processor 5100 Series.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n5000(165) Xeon processor 5000 Series.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
nLV(166) Xeon processor LV.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
nULV(167) Xeon processor ULV.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n7100(168) Xeon processor 7100 Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n5400(169) Intel Xeon processor 5400 Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n(170) Intel Xeon.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n5200(171) Xeon processor 5200 Series.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n7200(172) Xeon processor 7200 Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n7300(173) Intel Xeon processor 7300 Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n7400(174) Intel Xeon processor 7400 Series.
deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core
on7400(175) Intel Xeon processor 7400 Series.
deviceFamilyIsM1(176) The processor family is M1.

336 Device Group


book.book Page 337 Monday, March 14, 2011 3:01 PM

Table 14-6. Processor Device Family (continued)

Variable Name: DellProcessorDeviceFamily


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceFamilyIsM2(177) The processor family is M2.
deviceFamilyIsIntelPentium4HT The processor family is Intel Pentium 4
(179) HT processor.
deviceFamilyIsAS400(180) The processor family is AS400.
deviceFamilyIsAMDAthlonXP(182) The processor family is AMD Athlon
XP.
deviceFamilyIsAMDAthlonMP(183) The processor family is AMD Athlon
MP.
deviceFamilyIsAMDDuron(184) The processor family is AMD Duron.
deviceFamilyIsIntelPentiumM(185) The processor family is Intel Pentium M.
deviceFamilyIsIntelCeleronD(186) The processor family is Intel Celeron
D.
deviceFamilyIsIntelPentiumD(187) The processor family is Intel Pentium
D.
deviceFamilyIsIntelPentiumExtr The processor family is Intel Pentium
eme(188) Processor Extreme Edition.
deviceFamilyIsIntelCoreSolo The processor family is Intel Core Solo
(189) processor.
deviceFamilyIsIntelCore2(190) The processor family is Intel Core 2
processor.
deviceFamilyIsIntelCore2Duo The processor family is Intel Core 2
(191) Duo processor.
deviceFamilyIsIntelCore2Solo The processor family is Intel Core2
(192) Solo processor.
deviceFamilyIsIntelCore2Extrem The processor family is Intel Core2
e(193) Extreme processor.
deviceFamilyIsIntelCore2Quad The processor family is Intel Core2
(194) Quad processor.

Device Group 337


book.book Page 338 Monday, March 14, 2011 3:01 PM

Table 14-6. Processor Device Family (continued)

Variable Name: DellProcessorDeviceFamily


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceFamilyIsIntelCore2Extrem The processor family is Intel Core2
eMobile(195) Extreme mobile processor.
deviceFamilyIsIntelCore2DuoMob The processor family is Intel Core2
ile(196) Duo mobile processor.
deviceFamilyIsIntelCore2SoloMo The processor family is Intel Core2
bile(197) Solo mobile processor.
deviceFamilyIsIntelCorei7(198) The processor family is Intel Core i7
processor.
deviceFamilyIsDualCoreIntelCel The processor family is Dual-Core Intel
eron(199) Celeron Processor.
deviceFamilyIsIBM390(200) The processor family is IBM390.
deviceFamilyIsG4(201) The processor family is G4.
deviceFamilyIsG5(202) The processor family is G5.
deviceFamilyIsESA390G6(203) The processor family is ESA/390 G6.
deviceFamilyIszArchitectur The processor family is z/Architectur
(204) base.
deviceFamilyIsIntelCorei5(205) The processor family is Intel Core i5
processor.
deviceFamilyIsIntelCorei3(206) The processor family is Intel Core i3
processor.
deviceFamilyIsVIAC7-M(210) The processor family is VIA C7-M.
deviceFamilyIsVIAC7-D(211) The processor family is family is VIA
C7-D.
deviceFamilyIsVIAC7(212) The processor family is VIA C7.
deviceFamilyIsVIAEden(213) The processor family is VIA Eden.
deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core
on(214) Intel Xeon processor.

338 Device Group


book.book Page 339 Monday, March 14, 2011 3:01 PM

Table 14-6. Processor Device Family (continued)

Variable Name: DellProcessorDeviceFamily


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n3xxx(215) Xeon processor 3xxx Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n3xxx(216) Intel Xeon processor 3xxx Series.
deviceFamilyIsVIANano(217) The processor family is VIA Nano.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n5xxx(218) Xeon processor 5xxx Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n5xxx(219) Intel Xeon processor 5xxx Series.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n7xxx(221) Xeon processor 7xxx Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n7xxx(222) Intel Xeon processor 7xxx Series.
deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core
on7xxx(223) Intel Xeon processor 7xxx Series.
deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core
on3400(224) Intel Xeon processor 3400 Series.
deviceFamilyIsEmbeddedAMDOpert The processor family is Embedded
onQuadCore(230) AMD Opteron Quad-Core.
deviceFamilyIsAMDPhenomTripleC The processor family is AMD Phenom
ore(231) Triple-Core.
deviceFamilyIsAMDTurionUltraDu The processor family is AMD Turion
alCoreMobile(232) Ultra Dual-Core mobile processor.
deviceFamilyIsAMDTurionDualCor The processor family is AMD Turion
eMobile(233) Dual-Core mobile processor.
deviceFamilyIsAMDAthlonDualCor The processor family is AMD Athlon
e(234) Dual-Core.
deviceFamilyIsAMDSempronSI The processor family is AMD Sempron
(235) SI.

Device Group 339


book.book Page 340 Monday, March 14, 2011 3:01 PM

Table 14-6. Processor Device Family (continued)

Variable Name: DellProcessorDeviceFamily


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceFamilyIsAMDPhenomII(236) The processor family is AMD Phenom
II.
deviceFamilyIsAMDAthlonII(237) The processor family is AMD Athlon II.
deviceFamilyIsSixCoreAMDOptero The processor family is Six-Core AMD
n(238) Opteron.
deviceFamilyIsAMDSempronM(239) The processor family is AMD Sempron
M.
deviceFamilyIsi860(250) The processor family is i860.
deviceFamilyIsi960(251) The processor family is i960.

Table 14-7. Cache Device Type

Variable Name: DellCacheDeviceType


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceTypeIsOther(1) System cache type is not one of the
following:
deviceTypeIsUnknown(2) System cache type is unknown.
deviceTypeIsInstruction(3) System cache type is instruction.
deviceTypeIsData(4) System cache type is data.
deviceTypeIsUnified(5) System cache type is both instruction
and data.

340 Device Group


book.book Page 341 Monday, March 14, 2011 3:01 PM

Table 14-8. Cache Device Level

Variable Name: DellCacheDeviceLevel


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceLevelIsOther(1) Device level is not one of the following:
deviceLevelIsUnknown(2) Device level is unknown.
deviceLevelIsPrimary(3) Device level is primary.
deviceLevelIsSecondary(4) Device level is secondary.
deviceLevelIsTertiary(5) Device level is tertiary.

Table 14-9. Cache Device Write Policy

Variable Name: DellCacheDeviceWritePolicy


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceWritePolicyIsOther(1) Device write policy is not
one of the following:
deviceWritePolicyIsUnknown(2) Device write policy is
unknown.
deviceWritePolicyIsWriteBack(3) Device write policy is
write back.
deviceWritePolicyIsWriteThrough(4) Device write policy is
write through.
deviceWritePolicyIsVariesByAddress(5) Device write policy varies
by address.
deviceWritePolicyIsDeterminedByIO(6) Device write policy is
determined by I/O query.

Device Group 341


book.book Page 342 Monday, March 14, 2011 3:01 PM

Table 14-10. Cache Device Status State

Variable Name: DellCacheDeviceStatusState


Data Type: Integer
Possible Data Values Meaning of Data Value
other(1) Device state is not one of the following:
unknown(2) Device state is unknown.
enabled(3) Device is enabled.
userDisabled(4) Device is disabled by the user.
biosDisabled(5) Device basic input/output system
(BIOS) is disabled.

Table 14-11. Cache Device ECC Type

Variable Name: DellPointingDeviceType


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceTypeIsOther(1) Device type is not one of the following:
deviceTypeIsUnknown(2) Device type is unknown.
deviceTypeIsAMouse(3) Device type is a mouse.
deviceTypeIsATrackBall(4) Device type is a track ball.
deviceTypeIsATrackPoint(5) Device type is a track point.
deviceTypeIsAGlidePoint(6) Device type is a glide point.
deviceTypeIsATouchPad(7) Device type is a touch pad.

Table 14-12. Cache Device Associativity

Variable Name: DellCacheDeviceAssociativity


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceAssociativityIsOther(1) Device associativity is not
one of the following:

342 Device Group


book.book Page 343 Monday, March 14, 2011 3:01 PM

Table 14-12. Cache Device Associativity (continued)

Variable Name: DellCacheDeviceAssociativity


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceAssociativityIsUnknown(2) Device associativity is
unknown.
deviceAssociativityIsDirectMapped(3) Device is direct mapped.
deviceAssociativityIsTwoWaySetAsso Device is two-way set
ciative(4) associative.
deviceAssociativityIsFourWaySetAsso Device is four-way set
ciative(5) associative.
deviceAssociativityIsFullyAssociative Device is fully associative.
(6)
deviceAssociativityIsEightWaySetAsso Device is eight-way set
ciative(7) associative.
deviceAssociativityIsSixteenWaySet Device is sixteen-way set
Associative(8) associative.
deviceAssociativityIs12WaySetAssoc Device is 12-way
iative(9) Set-Associative.
deviceAssociativityIs24WaySetAssoc Device is 24-way
iative(10) Set-Associative.
deviceAssociativityIs32WaySetAssoc Device is 32-way
iative(11) Set-Associative.
deviceAssociativityIs48WaySetAssoc Device is 48-way
iative(12) Set-Associative.
deviceAssociativityIs64WaySetAssoc Device is 64-way
iative(13) Set-Associative.

Device Group 343


book.book Page 344 Monday, March 14, 2011 3:01 PM

Table 14-13. Cache Device Location

Variable Name: DellCacheDeviceLocation


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceLocationIsOther(1) Device location is not one of the
following:
deviceLocationIsUnknown(2) Device location is unknown.
deviceLocationIsInternal(3) Device location is internal.
deviceLocationIsExternal(4) Device location is external.

Table 14-14. Cache Device Static Random-Access Memory (SRAM) Type

Variable Name: DellCacheDeviceSRAMType


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceSRAMTypeIsOther(1) Device SRAM type is not one of the
following:
deviceSRAMTypeIsUnknown(2) Device SRAM type is unknown.
deviceSRAMTypeIsNonBurst(3) Device SRAM type is nonburst.
deviceSRAMTypeIsBurst(4) Device SRAM type is burst.
deviceSRAMTypeIsPipeBurst(5) Device SRAM type is pipeburst.
deviceSRAMTypeIsSynchronous(6) Device SRAM type is synchronous.
deviceSRAMTypeIsAsynchronous(7) Device SRAM type is asynchronous.

Table 14-15. Memory Device Type Form Factor

Variable Name: DellMemoryDeviceFormFactor


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceFormFactorIsOther(1) Device form factor is not one of
the following:

344 Device Group


book.book Page 345 Monday, March 14, 2011 3:01 PM

Table 14-15. Memory Device Type Form Factor (continued)

Variable Name: DellMemoryDeviceFormFactor


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceFormFactorIsUnknown(2) Device form factor is unknown.
deviceFormFactorIsSIMM(3) Device form factor is SIMM.
deviceFormFactorIsSIP(4) Device form factor is SIP.
deviceFormFactorIsAChip(5) Device form factor is a chip.
deviceFormFactorIsDIP(6) Device form factor is DIP.
deviceFormFactorIsZIP(7) Device form factor is ZIP.
deviceFormFactorIsAProprietaryCard Device form factor is a proprietary
(8) card.
deviceFormFactorIsDIMM(9) Device form factor is DIMM.
deviceFormFactorIsTSOP(10) Device form factor is TSOP.
deviceFormFactorIsARowOfChips(11) Device form factor is a row of
chips.
deviceFormFactorIsRIMM(12) Device form factor is RIMM.
deviceFormFactorIsSODIMM(13) Device form factor is SODIMM.
deviceFormFactorIsSRIMM(14) Device form factor is SRIMM.
deviceFormFactorIsFBDIMM(15) Device form factor is FB-DIMM.

Table 14-16. Memory Device Type

Variable Name: DellMemoryDeviceType


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceTypeIsOther(1) Device type is not one of the following:
deviceTypeIsUnknown(2) Device type is unknown.
deviceTypeIsDRAM(3) Device type is DRAM.
deviceTypeIsEDRAM(4) Device type is EDRAM.

Device Group 345


book.book Page 346 Monday, March 14, 2011 3:01 PM

Table 14-16. Memory Device Type (continued)

Variable Name: DellMemoryDeviceType


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceTypeIsVRAM(5) Device type is VRAM.
deviceTypeIsSRAM(6) Device type is SRAM.
deviceTypeIsRAM(7) Device type is RAM.
deviceTypeIsROM(8) Device type is ROM.
deviceTypeIsFLASH(9) Device type is FLASH.
deviceTypeIsEEPROM(10) Device type is EEPROM.
deviceTypeIsFEPROM(11) Device type is FEPROM.
deviceTypeIsEPROM(12) Device type is EPROM.
deviceTypeIsCDRAM(13) Device type is CDRAM.
deviceTypeIs3DRAM(14) Device type is 3DRAM.
deviceTypeIsSDRAM(15) Device type is SDRAM.
deviceTypeIsSGRAM(16) Device type is SGRAM.
deviceTypeIsRDRAM(17) Device type is RDRAM.
deviceTypeIsDDR(18) Device type is DDR.
deviceTypeIsDDR2(19) Device type is DDR2.
deviceTypeIsDDR2FBDIMM(20) Device type is DDR2 FB-DIMM.
deviceTypeIsDDR3(24) Device type is DDR3.
deviceTypeIsFBD2(25) Device type is FBD2.

346 Device Group


book.book Page 347 Monday, March 14, 2011 3:01 PM

Table 14-17. Memory Device Type Details


Variable Name: DellMemoryDeviceTypeDetails
Data Type: Integer
Possible Data Values Meaning of Data Value
deviceTypeDetailIsOther(2) The detailed device type is not one of the
following:
deviceTypeDetailIsUnknown(4) The detailed device type is unknown.
deviceTypeDetailIsFastPaged The detailed device type is fast paged.
(8)
deviceTypeDetailIsStaticColum The detailed device type is static column.
n(16)
deviceTypeDetailIsPseudoStati The detailed device type is pseudo-static.
c(32)
deviceTypeDetailIsRAMBUS(64) The detailed device type is RAMBUS.
deviceTypeDetailIsSynchronous The detailed device type is synchronous.
(128)
deviceTypeDetailIsCMOS(256) The detailed device type is CMOS.
deviceTypeDetailIsEDO(512) The detailed device type is EDO.
deviceTypeDetailIsWindowDRAM The detailed device type is Window
(1024) DRAM.
deviceTypeDetailIsCacheDRAM The detailed device type is Cache
(2048) DRAM.
deviceTypeDetailIsNonVolatile The detailed device type is Non-volatile.
(4096)
deviceTypeDetailIsRegistered The detailed device type is registered.
(8192)
deviceTypeDetailIsNonRegister The detailed device type is non-
ed(16384) registered.

Device Group 347


book.book Page 348 Monday, March 14, 2011 3:01 PM

Table 14-18. Generic Device Type

Variable Name: DellGenericDeviceType


Data Type: Integer
Possible Data Values Meaning of Data Value
deviceTypeIsOther(1) Device type is not one of the
following:
deviceTypeIsUnknown(2) Device type is unknown.
deviceTypeIsAVideoDevice(3) Device type is a video.
deviceTypeIsASCSIController(4) Device type is a SCSI controller.
deviceTypeIsAnEthernetDevice(5) Device type is Ethernet.
deviceTypeIsTokenRingDevice(6) Device type is token ring.
deviceTypeIsASoundDevice(7) Device type is sound.

Table 14-19. Memory Device Failure Modes

Variable Name: DellMemoryDeviceFailureModes


Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
(0) Memory device has no
faults.
eccSingleBitCorrectionWarningRate(1) Memory device has
exceeded the
Correctable Memory
Event warning rate.
eccSingleBitCorrectionFailureRate(2) Memory device has
exceeded the
Correctable Memory
Event failure rate.
eccMultiBitFault(4) Memory device has
encountered an
Uncorrectable Memory
Event.

348 Device Group


book.book Page 349 Monday, March 14, 2011 3:01 PM

Table 14-19. Memory Device Failure Modes (continued)

Variable Name: DellMemoryDeviceFailureModes


Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
eccSingleBitCorrectionLoggingDisabled(8) Correctable Memory
Event logging for
memory device has been
disabled.
deviceDisabledBySpareActivation(16) Memory device is
disabled because of spare
memory activation.

Table 14-20. Network Device Connection Status

Variable Name: DellNetworkDeviceConnectionStatus


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(0) Unable to determine connection status.
connected(1) Media reports that device is connected.
disconnected(2) Media reports that device is disconnected.
driverBad(3) Driver cannot be opened to determine status.
driverDisabled(4) Driver is disabled.
hardwareInitalizing(10) Hardware is initializing.
hardwareResetting(11) Hardware is resetting.
hardwareClosing(12) Hardware is closing down.
hardwareNotReady(13) Hardware is not ready.

Device Group 349


book.book Page 350 Monday, March 14, 2011 3:01 PM

Table 14-21. Network Device Teaming Flags

Variable Name: DellNetworkDeviceTeamingFlags


Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values Meaning of Data Value
undefined(0) Teaming flags are undefined.
noTeam(1) Device is not part of any team.
teamingEnabled(2) Teaming is enabled.
adapterFaultToleranceMode(4) Adapter fault tolerance teaming mode.
loadBalancingMode(8) Load balancing teaming mode.

Table 14-22. Network Device TOE Capability Flags

Variable Name: DellNetworkDeviceTOECapabilityFlags


Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values Meaning of Data Value
none(0) Querying for TOE capability is not supported.
unknown(1) Querying for TOE capability is supported but
query returned an error.
available(2) Device has TOE capability.
notAvailable(4) Device does not have TOE capability.
cannotBeDetermined(8) Querying for TOE capability is supported but
an error prevented querying.
driverNotResponding(16) Querying for TOE capability is supported but
driver did not respond to query.

350 Device Group


book.book Page 351 Monday, March 14, 2011 3:01 PM

Table 14-23. Network Device RDMA Capability Flags

Variable Name: DellNetworkDeviceRDMACapabilityFlags


Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values Meaning of Data Value
none(0) Querying for RDMA capability is not
supported.
unknown(1) Querying for RDMA capability is supported
but query returned an error.
available(2) Device has RDMA capability.
notAvailable(4) Device does not have RDMA capability.
cannotBeDetermined(8) Querying for RDMA capability is supported
but an error prevented querying.
driverNotResponding(16) Querying for RDMA capability is supported
but driver did not respond to query.

Table 14-24. Network Device iSCSI Capability Flags

Variable Name: DellNetworkDeviceiSCSICapabilityFlags


Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values Meaning of Data Value
none(0) Querying for iSCSI capability is not supported.
unknown(1) Querying for iSCSI capability is supported but
query returned an error.
available(2) Device has iSCSI capability.
notAvailable(4) Device does not have iSCSI capability.
cannotBeDetermined(8) Querying for iSCSI capability is supported but
an error prevented querying.
driverNotResponding(16) Querying for iSCSI capability is supported but
driver did not respond to query.

Device Group 351


book.book Page 352 Monday, March 14, 2011 3:01 PM

Table 14-25. Managed System Services Device Type


Variable Name: DellManagedSystemServicesDeviceType
Data Type: Integer
Possible Data Values Meaning of Data Value
baseDevice(0) Device type is base device.
optionalDevice(1) Device type is optional device.

Table 14-26. SD Card Device Type


Variable Name: DellSDCardDeviceType
Data Type: Integer
Possible Data Values Meaning of Data Value
other(1) Device type is other.
unknown(2) Device type is unknown.
hypervisor(3) Device type is Hypervisor.
vFlash(4) Device type is Virtual Flash (vFlash.)

Table 14-27. SD Card Device Config Capabilities


Variable Name: DellSDCardDeviceConfigCapabilities
Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values Meaning of Data Value
none(0) SD card device has none of the following
capabilities.
sdCapable(1) SD media can be enabled.
vFlashCapable(2) Virtual Flash (vFlash) can be enabled.

352 Device Group


book.book Page 353 Monday, March 14, 2011 3:01 PM

Table 14-28. SD Card Device Config Settings


Variable Name: DellSDCardDeviceConfigSettings
Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values Meaning of Data Value
none(0) SD card device has none of the following
settings.
sdEnabled(1) SD media is enabled.
vFlashEnabled(2) Virtual Flash (vFlash) is enabled.

Table 14-29. SD Card Device Card State


Variable Name: DellSDCardDeviceCardState
Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) SD card state is none of the following states.
present(1) Device is present.
ipmiReady(2) Device is IPMI ready.
fullReady(4) Device is full ready.
offline(8) Device is offline.
failed(16) Device is failed.
active(32) Device is active.
bootable(64) Device is bootable.
writeProtect(128) Device is write-protected.
standby(256) Device is in standby mode.

Table 14-30. SD Card Device Card Licensed


Variable Name: DellSDCardDeviceCardLicensed
Data Type: Integer
Possible Data Values Meaning of Data Value
unlicensed(0) SD card is not licensed by system vendor.

Device Group 353


book.book Page 354 Monday, March 14, 2011 3:01 PM

Variable Name: DellSDCardDeviceCardLicensed


Data Type: Integer
Possible Data Values Meaning of Data Value
licensed(1) SD card is licensed by system vendor.
ipmiReady(2) Device is IPMI ready.
fullReady(4) Device is full ready.
offline(8) Device is offline.
failed(16) Device is failed.
active(32) Device is active.
bootable(64) Device is bootable.
writeProtect(128) Device is write-protected.
standby(256) Device is in standby mode.

354 Device Group


book.book Page 355 Monday, March 14, 2011 3:01 PM

15
Slot Group
The Slot Group provides information about the types of slots that your
system supports. This management information base (MIB) group also
provides information about the voltages, capabilities, states, and settings that
are possible for these slots.

System Slot Group Table


The System Slot Group defines objects in the System Slot MIB table.

System Slot Table


The following object sets up the System Slot Table:

Name systemSlotTable
Object ID 1.3.6.1.4.1.674.10892.1.1200.10
Description Defines the System Slot Table.
Syntax IntegerSystemStateTableEntry
Access Not accessible

System Slot Table Entry

Name systemSlotTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1
Description Defines the System Slot Table entry.
Syntax IntegerSystemSlotTableEntry
Access Not accessible
Index systemSlotchassisIndex, systemSlotIndex

Slot Group 355


book.book Page 356 Monday, March 14, 2011 3:01 PM

System Slot Chassis Index

Name systemSlotchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

System Slot Index

Name systemSlotIndex
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2
Description Defines the index (one-based) of the system slot in this chassis.
Syntax DellObjectRange
Access Read-only

System Slot State Capabilities Unique

Name systemSlotStateCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.3
Description Defines the capabilities of the system slot.
Syntax DellSystemSlotStateCapabilities (See Table 15-1)
Access Read-only

System Slot State Settings Unique

Name systemSlotStateSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.4
Description Defines the state of the system slot.
Syntax DellSystemSlotStateSettings (See Table 15-2)
Access Read-only

356 Slot Group


book.book Page 357 Monday, March 14, 2011 3:01 PM

System Slot Status

Name systemSlotStatus
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.5
Description Defines the status of the system slot.
Syntax DellStatus
Access Read-only

System Slot Current Usage

Name systemSlotCurrentUsage
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.6
Description Defines the current usage of the system slot.
Syntax DellStatus
Access Read-only

System Slot Type

Name systemSlotType
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.7
Description Defines the type of the system slot.
Syntax DellSystemSlotType (See Table 15-3)
Access Read-only

System Slot External Slot Name

Name systemSlotSlotExternalSlotName
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.8
Description Defines the external connector name of the system slot.
Syntax DellString
Access Read-only

Slot Group 357


book.book Page 358 Monday, March 14, 2011 3:01 PM

System Slot Length

Name systemSlotLength
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.9
Description Defines the length of the system slot.
Syntax DellSystemSlotLength (See Table 15-5)
Access Read-only

System Slot Slot ID

Name systemSlotSlotID
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.10
Description Defines the slot identification number of the system slot. A zero (0)
indicates that the slot is embedded on the motherboard.
Syntax DellUnsigned32BitRange
Access Read-only

System Slot Category

Name systemSlotCategory
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.11
Description Defines the system slot category.
Syntax DellUnsigned32BitRange
Access Read-only

System Slot Hot-Plug Bus Width

Name systemSlotHotPlugBusWidth
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.12
Description Defines the bus width of the hot-plug system slot.
Syntax DellSystemSlotHotPlugBusWidth (See Table 15-7)
Access Read-only

358 Slot Group


book.book Page 359 Monday, March 14, 2011 3:01 PM

System Slot Hot-Plug Slot Speed

Name systemSlotHotPlugSlotSpeed
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.13
Description Defines the slot speed in megahertz of the hot-plug system slot.
A zero (0) indicates that the slot speed is unknown.
Syntax DellUnsigned32BitRange
Access Read-only

System Slot Hot-Plug Adapter Speed

Name systemSlotHotPlugAdapterSpeed
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.14
Description Defines the adapter speed in megahertz of the hot-plug system
slot. A zero (0) indicates that the slot speed is unknown.
Syntax DellUnsigned32BitRange
Access Read-only

System Slot Variable Values


This section includes definitions for server administrator-specific variable
values used in this section.

Table 15-1. System Slot State Capabilities

Variable Name: DellSystemSlotStateCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
systemSlotHotPlugIsUnknown The system slot’s capabilities are unknown.
(1)
systemSlotHotPlugIsHotPlug The system slot supports hot-plug.
gableCapable(2)
systemSlotHotPlugCanBePower The system slot power (and corresponding
edOn(4) light-emitting diode [LED]) can be
powered on.

Slot Group 359


book.book Page 360 Monday, March 14, 2011 3:01 PM

Table 15-1. System Slot State Capabilities (continued)

Variable Name: DellSystemSlotStateCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
systemSlotHotPlugCanSignal The system slot attention state
Attention(8) (and corresponding LED) can be set.
systemSlotHotPlugCanSignal Power on fault (and corresponding LED) can
PowerFault(16) be detected due to a short or overcurrent.
systemSlotHotPlugCanSignal Adapter (card) present in slot (may not be
AdapterPresent(32) powered) can be detected.
systemSlotHotPlugCanSignal The system slot power button can be pressed
PowerButtonPressed(64) to signal a toggle of the power state.
canSupportAllHotPlugCapabi The system slot can support all
lities(126) hot-plug capabilities.
systemSlotHotPlugIsUnknown The system slot’s capabilities are unknown.
(1)
systemSlotCanProvide5Volts The system slot can provide a
(128) 5-volt (V) supply.
systemSlotCanProvide3Point The system slot can provide a 3.3-V supply.
3Volts(256)
systemSlotCanSignalIfShared The system slot’s opening, if shared with
(512) another slot, can be detected.
systemSlotCanSupportCard16 The system slot can support
(1024) PC Card-16.
systemSlotCanSupportCardBus The system slot can support CardBus.
(2048)
systemSlotCanSupportZoomVid The system slot can support Zoom Video.
eo(4096)
systemSlotCanSupportModem The system slot can support modem
RingResume(8192) ring resume.
systemSlotCanSupportPMESig The system slot can support Power
nal(16384) Management Enable (PME#) signal.
canSupportAllSlotCapabilit The system slot can support all
ies(32640) slot capabilities.

360 Slot Group


book.book Page 361 Monday, March 14, 2011 3:01 PM

Table 15-2. System Slot State Settings

Variable Name: DellSystemSlotStateSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
systemSlotHotPlugIsUnknown(1) The system slot’s capabilities are
unknown.
systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug.
systemSlotHotPlugIsPoweredOn(4) The system slot power (and
corresponding LED) can be
powered on.
systemSlotHotPlugIsAtAttention(8) The system slot attention state (and
corresponding LED) can be set.
systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug.
systemSlotHotPlugIsPoweredOn(4) The system slot power (and
corresponding LED) is on.
systemSlotHotPlugIsAtAttention(8) The system slot attention state
(and corresponding LED) is on.
systemSlotHotPlugHasPowerFaulted Power on fault (and corresponding
(16) LED) was detected due to a short
or overcurrent.
systemSlotHotPlugAdapterIsPresent Adapter (card) present in slot
(32) (may not be powered).
systemSlotHotPlugAdapterPresentAnd Adapter (card) present in slot
PoweredOn(36) and powered.
systemSlotHotPlugPowerButtonPressed The system slot power button
(64) pressed to signal a toggle of the
power state.
systemSlotProvides5Volts(128) The system slot provides a 5-V
supply.
systemSlotProvides3Point3Volts(256) The system slot provides a 3.3-V
supply.
systemSlotIsShared(512) The slot’s opening is shared with
another slot.

Slot Group 361


book.book Page 362 Monday, March 14, 2011 3:01 PM

Table 15-2. System Slot State Settings (continued)

Variable Name: DellSystemSlotStateSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
systemSlotSupportsCard16(1024) The system slot supports PC
Card-16.
systemSlotSupportsCardBus(2048) The system slot supports
CardBus.
systemSlotSupportsZoomVideo(4096) The system slot supports zoom
video.
systemSlotSupportsModemRingResume The system slot supports modem
(8192) ring resume.
systemSlotSupportsPMESignal(16384) The system slot supports power
management enable (PME#)
signal.
supportsPMEand3P3Vand5VandHotPlugg The system slot supports power
able(16770) management enable.
supportsPMEand3P3Vand5VhasAdapterO The system slot supports power
n(16804) management event (PME),
supplies 3.3 V, and supplies 5 V.
The adapter is on.
supportsPMEand3P3Vand5VhasAdapter The system slot supports PME,
OnandisHotPluggable(16806) supplies 3.3 V, and supplies 5 V.
The adapter is on and the system
slot is hot pluggable.
supportsPMEand3P3VIsSharedand5Vhas The system slot supports PME,
AdapterOnandisHotPluggable(17316) supplies 3.3 V, supplies 5 V, and
shares a slot opening. The adapter
is on and the system slot is
hot pluggable.

362 Slot Group


book.book Page 363 Monday, March 14, 2011 3:01 PM

Table 15-3. System Slot Type

Variable Name: DellSystemSlotType


Data Type: Integer
Possible Data Values Meaning of Data Value
systemSlotIsOther(1) The system slot type is not one of
following:
systemSlotIsUnknown(2) The system slot type is unknown.
systemSlotIsISA(3) The system slot is Industry
Standard Architecture (ISA).
systemSlotIsMCA(4) The system slot is Micro Channel
Architecture (MCA).
systemSlotIsEISA(5) The system slot is Extended Industry
Standard Architecture (EISA).
systemSlotIsPCI(6) The system slot is Peripheral
Component Interconnect (PCI).
systemSlotIsPCMCIA(7) The system slot is compliant with
the Personal Computer Memory
Card International Association
(PCMCIA) standards.
systemSlotIsVLVESA(8) The system slot is Very Low Voltage
Enterprise System Architecture
(VLVESA).
systemSlotIsProprietary(9) The system slot is proprietary.
systemSlotIsProcessorCard(10) The system slot is a processor card.
systemSlotIsProprietaryMemory(11) The system slot is proprietary memory.
systemSlotIsIORiserCard(12) The system slot is an I/O riser card.
systemSlotIsNuBUS(13) The system slot is a NuBus.
systemSlotIsPCI66MHz(14) The system slot is a PCI66MHz.
systemSlotIsAGP(15) The system slot is an Advanced
Graphics Port (AGP).
systemSlotIsAGP2X(16) The system slot is an AGP 2x card.
systemSlotIsAGP4X(17) The system slot is an AGP 4x card.

Slot Group 363


book.book Page 364 Monday, March 14, 2011 3:01 PM

Table 15-3. System Slot Type (continued)

Variable Name: DellSystemSlotType


Data Type: Integer
Possible Data Values Meaning of Data Value
systemSlotIsPC98C20(18) The system slot is a PC-98/C20.
systemSlotIsPC98C24(19) The system slot is a PC-98/C24.
systemSlotIsPC98E(20) The system slot type is PC-98/E.
systemSlotIsPC98LocalBus(21) The system slot type is a PC-98
local bus.
systemSlotIsPC98Card(22) The system slot type is a PC-98 card.
systemSlotIsPCIX(23) The system slot type is a PCIX card.
systemSlotIsPCIExpress(24) The system slot type is a PCI
Express card.
systemSlotIsAGP8X(25) The system slot type is an AGP 8x
card.
systemSlotIsPCIExpressX1(166) The system slot type is a PCI
Express x1.
systemSlotIsPCIExpressX2(167) The system slot type is a PCI
Express x2.
systemSlotIsPCIExpressX4(168) The system slot type is a PCI
Express x4.
systemSlotIsPCIExpressX8(169) The system slot type is a PCI
Express x8.
systemSlotIsPCIExpressX16(170) The system slot type is a PCI
Express x16.
systemSlotIsPCIExpressGen2(171) The system slot type is PCI Express
Gen 2.
systemSlotIsPCIExpressGen2X1(172) The system slot type is PCI Express
Gen 2 x1.
systemSlotIsPCIExpressGen2X2(173) The system slot type is PCI Express
Gen 2 x2.

364 Slot Group


book.book Page 365 Monday, March 14, 2011 3:01 PM

Table 15-3. System Slot Type (continued)

Variable Name: DellSystemSlotType


Data Type: Integer
Possible Data Values Meaning of Data Value
systemSlotIsPCIExpressGen2X4(174) The system slot type is PCI Express
Gen 2 x4.
systemSlotIsPCIExpressGen2X8(175) The system slot type is PCI Express
Gen 2 x8.
systemSlotIsPCIExpressGen2X16(176) The system slot type is PCI Express
Gen 2 x16.

Table 15-4. System Slot Usage

Variable Name: DellSystemSlotUsage


Data Type: Integer
Possible Data Values Meaning of Data Value
systemSlotUsageIsOther(1) The system slot usage is not one of
following:
systemSlotUsageIsUnknown(2) The system slot usage is unknown.
systemSlotUsageIsAvailable(3) The system slot is available.
systemSlotUsageIsInUse(4) The system slot is in use.

Table 15-5. System Slot Length

Variable Name: DellSystemSlotLength


Data Type: Integer
Possible Data Values Meaning of Data Value
systemSlotLengthIsOther(1) The system slot length is not one of
following:
systemSlotLengthIsUnknown(2) The system slot length is unknown.
systemSlotLengthIsShort(3) The system slot length is short.
systemSlotLengthIsLong(4) The system slot length is long.

Slot Group 365


book.book Page 366 Monday, March 14, 2011 3:01 PM

Table 15-6. System Slot Category

Variable Name: DellSystemSlotCategory


Data Type: Integer
Possible Data Values Meaning of Data Value
systemSlotCategoryIsOther(1) The system slot category is not
one of following:
systemSlotCategoryIsUnknown(2) The system slot category is
unknown.
systemSlotCategoryIsBusConnector(3) The system slot is a bus
connector.
systemSlotCategoryIsPCMCIA(4) The system slot category is
PCMCIA.
systemSlotCategoryIsMotherboard(5) The system slot is a
motherboard.

Table 15-7. Hot-Plug Bus Width

Variable Name: DellSystemSlotHotPlugBusWidth


Data Type: Integer
Possible Data Values Meaning of Data Value
busWidthIsOther(1) The system slot bus width is not one of following:
busWidthIsUnknown(2) The system slot bus width is unknown.
busWidthIs8bits(3) The system slot bus width is 8 bits.
busWidthIs16bits(4) The system slot bus width is 16 bits.
busWidthIs32bits(5) The system slot bus width is 32 bits.
busWidthIs64bits(6) The system slot bus width is 64 bits.
busWidthIs128bits(7) The system slot bus width is 128 bits.
busWidthIs1xOrx1(8) The system slot bus width is 1x or x1.
busWidthIs2xOrx2(9) The system slot bus width is 2x or x2.
busWidthIs4xOrx4(10) The system slot bus width is 4x or x4.
busWidthIs8xOrx8(11) The system slot bus width is 8x or x8.

366 Slot Group


book.book Page 367 Monday, March 14, 2011 3:01 PM

Table 15-7. Hot-Plug Bus Width (continued)

Variable Name: DellSystemSlotHotPlugBusWidth


Data Type: Integer
Possible Data Values Meaning of Data Value
busWidthIs12xOrx12(12) The system slot bus width is 12x or x12.
busWidthIs16xOrx16(13) The system slot bus width is 16x or x16.
busWidthIs32xOrx32(14) The system slot bus width is 32x or x32.

NOTE: System slot bus width of type n bits are for parallel buses such as PCI.
NOTE: System slot bus width of type nx or xn are for serial buses such as
PCI Express.

Slot Group 367


book.book Page 368 Monday, March 14, 2011 3:01 PM

368 Slot Group


book.book Page 369 Monday, March 14, 2011 3:01 PM

16
Memory Group
The Memory Group provides information about the physical memory in your
system. Variables in this group include error correction type, location, and
different types of memory use, such as cache, flash, system, video, and
nonvolatile memory.

Physical Memory Tables


The following management information base (MIB) tables define the objects
in the Memory Group:
• "Physical Memory Array Table" on page 369
• "Physical Memory Array Mapped Table" on page 374
• "Physical Memory Configuration Table" on page 377
• "Physical Memory Logging Table" on page 379
• "Redundant Memory Unit Table" on page 381
• "Physical Memory Card Table" on page 384

Physical Memory Array Table


The physical memory array is the entire physical memory of a system.
The example that follows shows variable values for a system that has one
128-megabyte (MB) dual in-line memory module (DIMM):
• physicalMemoryArrayMaximumSize = 2,097,152 kilobytes (KB) or
2 gigabytes (GB)
• physicalMemoryArrayTotalNumberSockets = 4 (the example system has
four DIMM slots on the motherboard)
• physicalMemoryArrayInUseNumberSockets = 1 (there is only one DIMM
installed)

Memory Group 369


book.book Page 370 Monday, March 14, 2011 3:01 PM

The following object sets up the Physical Memory Array Table:

Name physicalMemoryArrayTable
Object ID 1.3.6.1.4.1.674.10892.1.1300.10
Description Defines the Physical Memory Array Table.
Syntax PhysicalMemoryArrayTableEntry
Access Not accessible

Physical Memory Array Table Entry

Name physicalMemoryArrayTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1
Description Defines the Physical Memory Array Table entry.
Syntax PhysicalMemoryArrayTableEntry
Access Not accessible
Index physicalMemoryArraychassisIndex, physicalMemoryArrayIndex

Physical Memory Array Chassis Index

Name physicalMemoryArraychassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Physical Memory Array Index

Name physicalMemoryArrayIndex
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.2
Description Defines the index (one-based) of the physical memory array in
this chassis.
Syntax DellObjectRange
Access Read-only

370 Memory Group


book.book Page 371 Monday, March 14, 2011 3:01 PM

Physical Memory Array State Capabilities

Name physicalMemoryArrayStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.3
Description Defines the capabilities of the physical memory array.
Syntax DellStateCapabilities
Access Read-only

Physical Memory Array State Settings

Name physicalMemoryArrayStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.4
Description Defines the state of the physical memory array.
Syntax DellStateSettings
Access read-write

Physical Memory Array Status

Name physicalMemoryArrayStatus
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.5
Description Defines the status of the physical memory array.
Syntax DellStatus
Access Read-only

Physical Memory Array Use

Name physicalMemoryArrayUse
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.6
Description Defines the use of the physical memory array.
Syntax DellPhysicalMemoryArrayUse (See Table 16-2)
Access Read-only

Memory Group 371


book.book Page 372 Monday, March 14, 2011 3:01 PM

Physical Memory Array Error Checking and Correcting (ECC) Type

Name physicalMemoryArrayECCType
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.7
Description Defines the ECC type used by the physical memory array.
Syntax DellPhysicalMemoryArrayECCType (See Table 16-2)
Access Read-only

Physical Memory Array Location

Name physicalMemoryArrayLocation
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.8
Description Defines the location of the physical memory array.
Syntax DellPhysicalMemoryArrayLocation (See Table 16-1)
Access Read-only

Physical Memory Array Maximum Size

Name physicalMemoryArrayMaximumSize
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.9
Description Defines the size in KB of the physical memory array.
Syntax DellUnsigned32BitRange
Access Read-only

Physical Memory Array Total Number Sockets

Name physicalMemoryArrayTotalNumberSockets
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.10
Description Defines the total number of memory sockets available for the
physical memory array.
Syntax DellUnsigned32BitRange
Access Read-only

372 Memory Group


book.book Page 373 Monday, March 14, 2011 3:01 PM

Physical Memory Array In Use Number Sockets

Name physicalMemoryArrayInUseNumberSockets
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.11
Description Defines the total number of memory sockets in use by the
physical memory array.
Syntax DellUnsigned32BitRange
Access Read-only

Physical Memory Array ECC Error Nonrecoverable Threshold

Name physicalMemoryArrayECCErrorNonRecoverbeThreshold
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.12
Description Defines the value of the physical memory array Error Checking and
Correction (ECC) error nonrecoverable threshold.
Syntax DellSigned32BitRange
Access Read-only

Physical Memory Array ECC Error Critical Threshold

Name physicalMemoryArrayECCErrorCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.13
Description Defines the value of the physical memory array ECC error critical
threshold.
Syntax DellSigned32BitRange
Access Read-only

Physical Memory Array ECC Error Noncritical Threshold

Name physicalMemoryArrayECCErrorNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.14
Description Defines the value of the physical memory array ECC error
noncritical threshold.
Syntax DellSigned32BitRange
Access read-write

Memory Group 373


book.book Page 374 Monday, March 14, 2011 3:01 PM

Physical Memory Array Redundant Memory Unit Index Reference

Name physicalMemoryArrayRedundantMemoryUnitIndex
Reference
Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.15
Description Defines the index to the associated Redundant Memory Unit in
this chassis.
Syntax DellObjectRange
Access Read-only

Physical Memory Array Mapped Table


The physical memory array is divided into memory array mapped addresses.
The following object sets up the Physical Memory Array Mapped Table:

Name physicalMemoryArrayMappedTable
Object ID 1.3.6.1.4.1.674.10892.1.1300.20
Description Defines the Physical Memory Array Mapped Table.
Syntax PhysicalMemoryArrayMappedTableEntry
Access Not accessible

Physical Memory Array Mapped Table Entry

Name PhysicalMemoryArrayMappedTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1
Description Defines the Physical Memory Array Mapped Table entry.
Syntax PhysicalMemoryArrayMappedTableEntry
Access Not accessible
Index physicalMemoryArrayMappedchassisIndex,
physicalMemoryArrayMappedIndex

374 Memory Group


book.book Page 375 Monday, March 14, 2011 3:01 PM

Physical Memory Array Mapped Chassis Index

Name physicalMemoryArrayMappedchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Physical Memory Array Mapped Index

Name physicalMemoryArrayMappedIndex
Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.2
Description Defines the index (one-based) of the memory array mapped
address in this chassis.
Syntax DellObjectRange
Access Read-only

Physical Memory Array Mapped State Capabilities

Name physicalMemoryArrayMappedStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.3
Description Defines the capabilities of the memory array mapped address.
Syntax DellStateCapabilities
Access Read-only

Physical Memory Array Mapped State Settings

Name physicalMemoryArrayMappedStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.4
Description Defines the state of the memory array mapped address.
Syntax DellStateSettings
Access Read-write

Memory Group 375


book.book Page 376 Monday, March 14, 2011 3:01 PM

Physical Memory Array Mapped Status

Name physicalMemoryArrayMappedStatus
Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.5
Description Defines the status of the memory array mapped address.
Syntax DellStatus
Access Read-only

Physical Memory Array Index Reference

Name physicalMemoryArrayIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.6
Description Defines the index to the associated physical memory array in this
chassis.
Syntax DellObjectRange
Access Read-only

Physical Memory Array Mapped Starting Address

Name physicalMemoryArrayMappedStartingAddress
Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.7
Description Defines the physical starting address in KB of the memory array
mapped address.
Syntax DellUnsigned64BitRange
Access Read-only

Physical Memory Array Mapped Ending Address

Name physicalMemoryArrayMappedEndingAddress
Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.8
Description Defines the physical ending address in KB of the memory array
mapped address.
Syntax DellUnsigned64BitRange
Access Read-only

376 Memory Group


book.book Page 377 Monday, March 14, 2011 3:01 PM

Physical Memory Array Mapped Partition Width

Name physicalMemoryArrayMappedPartitionWidth
Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.9
Description Defines the number of memory devices that form a single row in
the memory array mapped address. A zero (0) indicates that the
number is unknown.
Syntax DellUnsigned32BitRange
Access Read-only

Physical Memory Configuration Table


This table defines how the physical memory of a system chassis is set up, for
example, which redundant memory types are supported and whether
redundant memory is active.
The following object sets up the Physical Memory Configuration Table:

Name physicalMemoryConfigTable
Object ID 1.3.6.1.4.1.674.10892.1.1300.30
Description Defines the Physical Memory Configuration Table.
Syntax SEQUENCE OF PhysicalMemoryConfigTableEntry
Access Not accessible

Physical Memory Configuration Table Entry

Name physicalMemoryConfigTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1
Description Defines the Physical Memory Configuration Table entry.
Syntax PhysicalMemoryConfigTableEntry
Access Not accessible
Index physicalMemoryConfigChassisIndex,
physicalMemoryConfigIndex

Memory Group 377


book.book Page 378 Monday, March 14, 2011 3:01 PM

Physical Memory Configuration Chassis Index

Name physicalMemoryConfigChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.1
Description Defines the index (one-based) of the chassis associated with the
physical memory configuration.
Syntax DellObjectRange
Access Read-only

Physical Memory Configuration Index

Name physicalMemoryConfigIndex
Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.2
Description Defines the index (one-based) of the physical memory
configuration.
Syntax DellObjectRange
Access Read-only

Physical Memory Configuration State Capabilities

Name physicalMemoryConfigStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.3
Description Defines the state capabilities of the physical memory configuration.
Syntax DellPhysicalMemoryConfigStateCapabilities
Access Read-only

Physical Memory Configuration State Settings

Name physicalMemoryConfigStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.4
Description Defines the state settings of the physical memory configuration.
Syntax DellPhysicalMemoryConfigStateSettings
Access Read-write

378 Memory Group


book.book Page 379 Monday, March 14, 2011 3:01 PM

Physical Memory Configuration Status

Name physicalMemoryConfigStatus
Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.5
Description Defines the status of the physical memory configuration.
Syntax DellStatus
Access Read-only

Physical Memory Configuration Redundant Capabilities

Name physicalMemoryConfigRedundantCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.6
Description Defines the redundant capabilities of the physical memory.
Syntax DellPhysicalMemoryConfigRedundantCapabilities
Access Read-only

Physical Memory Configuration Redundant Settings

Name physicalMemoryConfigRedundantSettings
Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.7
Description Defines the redundant settings of the physical memory.
Syntax DellPhysicalMemoryConfigRedundantSettings
Access Read-write

Physical Memory Logging Table


This table defines the conditions for logging system memory events.
The following object sets up the Physical Memory Logging Table:

Name physicalMemoryLoggingTable
Object ID 1.3.6.1.4.1.674.10892.1.1300.40
Description Defines the Physical Memory Logging Table.
Syntax SEQUENCE OF PhysicalMemoryLoggingTableEntry
Access Not accessible

Memory Group 379


book.book Page 380 Monday, March 14, 2011 3:01 PM

Physical Memory Logging Table Entry

Name physicalMemoryLoggingTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1
Description Defines the Physical Memory Logging Table entry.
Syntax PhysicalMemoryLoggingTableEntry
Access Not accessible
Index physicalMemoryLoggingChassisIndex,
physicalMemoryLoggingIndex

Physical Memory Logging Chassis Index

Name physicalMemoryLoggingChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.1
Description Defines the index (one-based) of the chassis associated with the
physical memory logging.
Syntax DellObjectRange
Access Read-only

Physical Memory Logging Index

Name physicalMemoryLoggingIndex
Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.2
Description Defines the index (one-based) of the physical memory logging.
Syntax DellObjectRange
Access Read-only

Physical Memory Logging Capabilities

Name physicalMemoryLoggingCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.3
Description Defines the capabilities of the physical memory logging.
Syntax DellPhysicalMemoryLoggingCapabilities
Access Read-only

380 Memory Group


book.book Page 381 Monday, March 14, 2011 3:01 PM

Physical Memory Logging Settings

Name physicalMemoryLoggingSettings
Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.4
Description Defines the settings of the physical memory logging.
Syntax DellPhysicalMemoryLoggingSettings
Access Read-write

Physical Memory Logging Status

Name physicalMemoryLoggingStatus
Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.5
Description Defines the status of the physical memory logging.
Syntax DellStatus
Access Read-only

Redundant Memory Unit Table


This table reports the status of redundant memory within a particular system
chassis.
The following object sets up the Redundant Memory Unit Table:

Name redundantMemoryUnitTable
Object ID 1.3.6.1.4.1.674.10892.1.1300.50
Description Defines the Redundant Memory Unit Table.
Syntax SEQUENCE OF RedundantMemoryUnitTableEntry
Access Not accessible

Memory Group 381


book.book Page 382 Monday, March 14, 2011 3:01 PM

Redundant Memory Unit Table Entry

Name redundantMemoryUnitTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1
Description Defines the Redundant Memory Unit Table entry.
Syntax RedundantMemoryUnitTableEntry
Access Not accessible
Index redundantMemoryUnitChassisIndex,
redundantMemoryUnitIndex

Redundant Memory Unit Chassis Index

Name redundantMemoryUnitChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.1
Description Defines the index (one-based) of the chassis associated with the
redundant memory unit.
Syntax DellObjectRange
Access Read-only

Redundant Memory Unit Index

Name redundantMemoryUnitIndex
Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.2
Description Defines the index (one-based) of the redundant memory unit.
Syntax DellObjectRange
Access Read-only

Redundant Memory Unit State Capabilities

Name redundantMemoryUnitStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.3
Description Defines the state capabilities of the redundant memory unit.
Syntax DellStateCapabilities
Access Read-only

382 Memory Group


book.book Page 383 Monday, March 14, 2011 3:01 PM

Redundant Memory Unit State Settings

Name redundantMemoryUnitStatesettings
Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.4
Description Defines the state settings of the redundant memory unit.
Syntax DellStateSettings
Access Read-write

Redundant Memory Unit Redundancy Status

Name redundantMemoryUnitRedundancyStatus
Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.5
Description Defines the redundancy status of the redundant memory unit.
Syntax DellStatusRedundancy
Access Read-only

Redundant Memory Unit Name

Name redundantMemoryUnitName
Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.6
Description Defines the name of the redundant memory unit.
Syntax DellString
Access Read-only

Redundant Memory Unit Status

Name redundantMemoryUnitStatus
Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.7
Description Defines the status of the redundant memory unit.
Syntax DellStatus
Access Read-only

Memory Group 383


book.book Page 384 Monday, March 14, 2011 3:01 PM

Physical Memory Card Table


This table defines the name of the memory card, the total number of device
slots present on the memory card, and the number of memory device slots in
use on the memory card.
The following objects set up the Physical Memory Card Table:

Physical Memory Card Table

Name physicalMemoryCardTable
Object ID 1.3.6.1.4.1.674.10892.1.1300.60
Description Defines the Physical Memory Card Table.
Syntax SEQUENCE OF PhysicalMemoryCardTableEntry
Access Not accessible

Physical Memory Card Table Entry

Name physicalMemoryCardTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1
Description Defines the Physical Memory Card Table Entry.
Syntax PhysicalMemoryCardTableEntry
Access Not accessible
Index physicalMemoryCardChassisIndex, physicalMemoryCardIndex

Physical Memory Card Chassis Index

Name physicalMemoryCardChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellObjectRange
Access Read-only

384 Memory Group


book.book Page 385 Monday, March 14, 2011 3:01 PM

Physical Memory Card Index

Name physicalMemoryCardIndex
Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.2
Description Defines the index (one-based) of the Physical Memory Card.
Syntax DellObjectRange
Access Read-only

Physical Memory Card State Capabilities

Name physicalMemoryCardStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.3
Description Defines the state capabilities of the Physical Memory Card.
Syntax DellStateCapabilities
Access Read-only

Physical Memory Card State Settings

Name physicalMemoryCardStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.4
Description Defines the state settings of the Physical Memory Card.
Syntax DellStateSettings
Access Read-write

Physical Memory Card Status

Name physicalMemoryCardStatus
Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.5
Description Defines the status of the Physical Memory Card.
Syntax DellStatus
Access Read-only

Memory Group 385


book.book Page 386 Monday, March 14, 2011 3:01 PM

Physical Memory Card Name

Name physicalMemoryCardName
Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.6
Description Defines the name of the Physical Memory Card.
Syntax DellString
Access Read-only

Physical Memory Card Total Number Sockets

Name physicalMemoryCardTotalNumberSockets
Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.7
Description Defines the total number of memory sockets available on the
Physical Memory Card. 2,147,483,647 indicates an unknown
number of sockets.
Syntax DellUnsigned32BitRange
Access Read-only

Physical Memory Card In Use Number Sockets

Name physicalMemoryCardInUseNumberSockets
Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.8
Description Defines the number of memory sockets in use on the Physical
Memory Card. Zero indicates that the Physical Memory Card is
not installed or has a configuration error.
Syntax DellUnsigned32BitRange
Access Read-only

386 Memory Group


book.book Page 387 Monday, March 14, 2011 3:01 PM

Physical Memory Card Physical Memory Array Index Reference

Name physicalMemoryCardPhyMemArrayIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.9
Description Defines the index (one-based) of the Physical Memory Array
Table entry for the physical memory array with the same chassis
index that this physical memory card is associated with.
Syntax DellObjectRange
Access Read-only

Memory Group Variable Values


This section includes definitions for server administrator-specific variable
values used in this section.

Table 16-1. Physical Memory Array Location

Variable Name: DellPhysicalMemoryArrayLocation


Data Type: Integer
Possible Data Values Meaning of Data Value
memoryArrayLocationIsOther(1) The memory array
location is not one of the
following:
memoryArrayUseIsUnknown(2) The memory array use is
unknown.
memoryArrayUseIsSystemMemory(3) The memory array is
system memory.
memoryArrayUseIsVideoMemory(4) The memory array is video
memory.
memoryArrayUseIsFLASHMemory(5) The memory array is
FLASH memory.
memoryArrayUseIsNonVolatileRAMMemory(6) The memory array is
nonvolatile RAM.
memoryArrayUseIsCacheMemory(7) The memory array is cache
memory.

Memory Group 387


book.book Page 388 Monday, March 14, 2011 3:01 PM

Table 16-1. Physical Memory Array Location (continued)

Variable Name: DellPhysicalMemoryArrayLocation


Data Type: Integer
Possible Data Values Meaning of Data Value
memoryArrayLocationIsPCMCIA(8) The memory array
location is a Personal
Computer Memory Card
International Association
(PCMCIA) option card.
memoryArrayLocationIsProprietary(9) The memory array
location is a proprietary
option card.
memoryArrayLocationIsNUBUS(10) The memory array
location is a NuBus bus.
memoryArrayLocationIsPC98C20(11) The memory array
location is a PC-98/C20
option card.
memoryArrayLocationIsPC98C24(12) The memory array
location is a PC-98/C24
option card.
memoryArrayLocationIsPC98E(13) The memory array
location is a PC-98/E
option card.
memoryArrayLocationIsPC98LocalBus(14) The memory array
location is a PC-98/Local
bus option card.
memoryArrayLocationIsPC98Card(15) The memory array
location is a PC-98/Card
slot option card.

388 Memory Group


book.book Page 389 Monday, March 14, 2011 3:01 PM

Table 16-2. Physical Memory Array ECC Type Definitions

Variable Name: DellPhysicalMemoryArrayECCType


Data Type: Integer
Possible Data Values Meaning of Data Value
memoryArrayECCTypeIsOther(1) There is not one of the following:
memoryArrayECCTypeIsUnknown(2) The memory array ECC type is
unknown.
memoryArrayECCTypeIsNone(3) The memory array ECC type is
none.
memoryArrayECCTypeIsParity(4) The memory array ECC type is
parity.
memoryArrayECCTypeIsSingleBitECC(5) The memory array ECC type is
Correctable Memory Event ECC.
memoryArrayECCTypeIsMultiBitECC(6) The memory array ECC type is
Uncorrectable Memory Event
ECC.
memoryArrayECCTypeIsCRC(7) The memory array ECC type is
CRC.

Table 16-3. Physical Memory Configuration State Capabilities

Variable Name: DellPhysicalMemoryConfigStateCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
If set to 0 (zero) There are no state capabilities.
unknownCapabilities(1) State capabilities are unknown.
enableCapable(2) Object enable/disable is supported.
notReadyCapable(4) Object not ready is supported.

Memory Group 389


book.book Page 390 Monday, March 14, 2011 3:01 PM

Table 16-4. Physical Memory Configuration State Settings

Variable Name: DellPhysicalMemoryConfigStateSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
If set to 0 (zero) There are no state settings.
unknown(1) State settings are unknown.
enabled(2) Object is disabled (offline) 0,
or enabled (online) 1.
notReady(4) Object not ready.
redundantMemoryIsActive(8) Redundant memory is active
(in use)
enabledAndRedundantMemoryIsActive(10) Redundant memory is
enabled and in use.

Table 16-5. Physical Memory Configuration Redundant Capabilities

Variable Name:
DellPhysicalMemoryConfigRedundantCapabilities
Data Type: Integer
Possible Data Values Meaning of Data Value
If set to 0 (zero) There are no redundant memory capabilities.
unknownCapabilities(1) Redundant capabilities are unknown.
The redundant capabilities are:
spareCapable(2) Spare redundant memory feature is supported.
mirrorCapable(4) Mirror redundant memory feature is supported.
spareAndMirrorCapable(6) Spare and mirror redundant memory features are
supported.
raidCapable(8) Redundant Array of Independent disks (RAID)
redundant memory feature is supported.

390 Memory Group


book.book Page 391 Monday, March 14, 2011 3:01 PM

Table 16-6. Physical Memory Configuration Redundant Settings

Variable Name:
DellPhysicalMemoryConfigRedundantSettings
Data Type: Integer
Possible Data Values Meaning of Data Value
If set to 0 (zero) There are no redundant memory settings enabled.
unknown(1) Redundant settings are unknown.
The following redundant settings are mutually exclusive:
spareEnabled(2) Spare redundant memory feature is enabled.
mirrorEnabled(4) Mirror redundant memory feature is enabled.
raidEnabled(8) RAID redundant memory feature is enabled.

Table 16-7. Physical Memory Logging Capabilities

Variable Name: DellPhysicalMemoryLoggingCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
If set to 0 (zero) There are no logging capabilities.
unknown Capabilities(1) Logging capabilities are unknown.
The logging capabilities are:
enableCapable(2) Logging enable/disable using Simple Network
Management Protocol (SNMP) is supported.

Memory Group 391


book.book Page 392 Monday, March 14, 2011 3:01 PM

Table 16-8. Physical Memory Logging Settings

Variable Name: DellPhysicalMemoryLoggingSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
If set to 0 (zero) There are no logging settings enabled.
unknown Capabilities(1) Logging capabilities are unknown.
The logging settings are:
enabled(2) Logging is disabled (0), or enabled (1).

392 Memory Group


book.book Page 393 Monday, March 14, 2011 3:01 PM

17
BIOS Setup Control Group
Basic Input/Output System (BIOS) Setup Control Group variables provide
information about the functions that the BIOS performs in your system.
This management information base (MIB) group includes variables for the
boot sequence, speakers, diskettes, ports, network interface controllers (NICs),
and the Wakeup on local area network (LAN) feature.

BIOS Group Tables


The objects in this group define the BIOS control of devices and controller
cards that are typically present in a system. The following MIB tables define
the BIOS Setup Control Group:
• "BIOS Setup Control Table" on page 393
• "SCSI Control Table" on page 404
• "Parallel Port Control Table" on page 406
• "Serial Port Control Table" on page 408
• "USB Control Table" on page 410
• "IDE Control Table" on page 412
• "Diskette Control Table" on page 414
• "Network Interface Control Table" on page 416

BIOS Setup Control Table

Name biosSetUpControlTable
Object ID 1.3.6.1.4.1.674.10892.1.1400.10
Description Defines the set of single devices in a chassis controlled by the
BIOS.
Syntax BiosSetUpControlTableEntry
Access Not accessible

BIOS Setup Control Group 393


book.book Page 394 Monday, March 14, 2011 3:01 PM

BIOS Setup Control Table Entry

Name biosSetUpControlTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1
Description Defines the BIOS Control Device Table entry.
Syntax BiosSetUpControlTableEntry
Access Not accessible
Index biosSetUpControlchassisIndex

BIOS Setup Control Chassis Index

Name biosSetUpControlchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

BIOS Setup Control (BSUC) Pointing Device Control Capabilities

Name bSUCpointingDeviceControlCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.2
Description Defines the capabilities of the pointing device.
Syntax DellStateCapabilities
Access Read-only

BIOS Setup Control Pointing Device Control Settings

Name bSUCpointingDeviceControlSettings
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.3
Description Defines the state of the pointing device.
Syntax DellStateSettings
Access Read-write

394 BIOS Setup Control Group


book.book Page 395 Monday, March 14, 2011 3:01 PM

BIOS Setup Control Pointing Device Control Status

Name bSUCpointingDeviceControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.4
Description Defines the status of the pointing device.
Syntax DellStatus
Access Read-only

BIOS Setup Control Pointing Device Control Name

Name bSUCpointingDeviceControlName
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.5
Description Defines the setup BIOS name of the pointing device.
Syntax DellString
Access Read-only

BIOS Setup Control Numeric Lock Control Capabilities

Name bSUCnumLockControlCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.6
Description Defines the capabilities of the numeric lock.
Syntax DellStateCapabilities
Access Read-only

BIOS Setup Control Numeric Lock Control Settings

Name bSUCnumLockControlSettings
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.7
Description Defines the state of the numeric lock.
Syntax DellStateSettings
Access Read-only

BIOS Setup Control Group 395


book.book Page 396 Monday, March 14, 2011 3:01 PM

BIOS Setup Control Numeric Lock Control Status

Name bSUCnumLockControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.8
Description Defines the status of the numeric lock.
Syntax DellStatus
Access Read-only

BIOS Setup Control Numeric Lock Control Name

Name bSUCnumLockControlName
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.9
Description Defines the setup BIOS name of the numeric lock.
Syntax DellString
Access Read-only

BIOS Setup Control Processor Serial Number Control Capabilities

Name bSUCprocessorSerialNumberControlCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.10
Description Defines if the processor serial number can be returned.
Syntax DellStateCapabilities
Access Read-only

BIOS Setup Control Processor Serial Number Control Settings

Name bSUCprocessorSerialNumberControlSettings
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.11
Description Defines the state of the processor serial number.
Syntax DellStateSettings
Access Read-only

396 BIOS Setup Control Group


book.book Page 397 Monday, March 14, 2011 3:01 PM

BIOS Setup Control Processor Serial Number Control Status

Name bSUCprocessorSerialNumberControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.12
Description Defines the status of the processor serial number.
Syntax DellStatus
Access Read-only

BIOS Setup Control Processor Serial Number Control Name

Name bSUCprocessorSerialNumberControlName
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.13
Description Defines the setup BIOS name of the processor serial number.
Syntax DellString
Access Read-write

BIOS Setup Control Speaker Control Capabilities Unique

Name bSUCspeakerControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.14
Description Defines the capabilities of the speaker control.
Syntax DellSpeakerControlCapabilitiesUnique (See Table 17-1)
Access Read-only

BIOS Setup Control Speaker Control Settings Unique

Name bSUCspeakerControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.15
Description Defines the settings available for speaker control.
Syntax DellSpeakerControlSettingsUnique (See Table 17-2)
Access Read-only

BIOS Setup Control Group 397


book.book Page 398 Monday, March 14, 2011 3:01 PM

BIOS Setup Control Speaker Control Status

Name bSUCspeakerControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16
Description Defines the status of speaker control.
Syntax DellStatus
Access Read-only

BIOS Setup Control Speaker Control Name

Name bSUCspeakerControlName
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.17
Description Defines the setup BIOS name of the speaker control.
Syntax DellString
Access Read-only

BIOS Setup Control NIF Wakeup on LAN Control Capabilities Unique

Name bSUCnIFwakeonLanControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.18
Description Defines the defines the capabilities of the network interface
function (NIF) Wakeup on LAN.
Syntax DellNIFwakeonLanControlCapabilitiesUnique (See Table 17-4)
Access Read-only

BIOS Setup Control NIF Wakeup on LAN Control Settings Unique

Name bSUCnIFwakeonLanControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.19
Description Defines the state of the NIF Wakeup on LAN.
Syntax DellNIFwakeonLanControlSettingsUnique (See Table 17-4)
Access Read-only

398 BIOS Setup Control Group


book.book Page 399 Monday, March 14, 2011 3:01 PM

BIOS Setup Control NIF Wakeup on LAN Control Status

Name bSUCnIFwakeonLanControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.20
Description Defines the status of the NIF Wakeup on LAN.
Syntax DellStatus
Access Read-only

BIOS Setup Control NIF Wakeup on LAN Control Name

Name bSUCnIFwakeonLanControlName
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.21
Description Defines the setup BIOS name of the NIF Wakeup on LAN.
Syntax DellString
Access Read-only

BIOS Setup Control Boot Sequence Control Capabilities Unique

Name bSUCbootSequenceControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.22
Description Defines the capabilities of the boot sequence.
Syntax DellBootSequenceControlCapabilitiesUnique (See Table 17-5)
Access Read-only

BIOS Setup Control Boot Sequence Control Settings Unique

Name DellBootSequenceControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.23
Description Defines the state of the boot sequence.
Syntax DellBootSequenceControlSettingsUnique (See Table 17-6)
Access Read-only

BIOS Setup Control Group 399


book.book Page 400 Monday, March 14, 2011 3:01 PM

BIOS Setup Control Boot Sequence Control Status

Name bSUCbootSequenceControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.24
Description Defines the status of the boot sequence.
Syntax DellStatus
Access Read-only

BIOS Setup Control Boot Sequence Control Name

Name bSUCbootSequenceControlName
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.25
Description Defines the control name of the boot sequence.
Syntax DellString
Access Read-only

BIOS Setup Control Administrator Password Control Capabilities Unique

Name bSUCadministratorPasswordControlCapabilities
Unique
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.26
Description Defines the capabilities of the administrator password control.
Syntax DellBIOSPasswordControlCapabilitiesUnique
Access Read-only

BIOS Setup Control Administrator Password Control Settings Unique

Name bSUCadministratorPasswordControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.27
Description Defines the settings for administrator password control.
Syntax DellBIOSPasswordControlSettingsUnique (See Table 17-9)
Access Read-write

400 BIOS Setup Control Group


book.book Page 401 Monday, March 14, 2011 3:01 PM

BIOS Setup Control Administrator Password Control Status

Name bSUCadministratorPasswordControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.28
Description Defines the status for administrator password control.
Syntax DellStatus
Access Read-only

BIOS Setup Control Administrator Password Verify Name

Name bSUCadministratorPasswordVerifyName
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.29
Description Defines the setup BIOS name for the current administrator password.
Syntax DellString
Access Read-write

BIOS Setup Control Administrator Password New Password Name

Name bSUCadministratorPasswordNewPasswordName
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.30
Description Defines the setup BIOS name of the new administrator
password. To set a new administrator password, you must have
successfully set the current administrator password immediately
preceding this password change.
Syntax DellString
Access Read-write

BIOS Setup Control User Password Control Capabilities Unique

Name bSUCuserPasswordControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.31
Description Defines the capabilities of user password control.
Syntax DellBIOSPasswordControlCapabilitiesUnique
Access Read-only

BIOS Setup Control Group 401


book.book Page 402 Monday, March 14, 2011 3:01 PM

BIOS Setup Control User Password Control Settings Unique

Name bSUCuserPasswordControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.32
Description Defines the control settings for user password control.
Syntax DellBIOSPasswordControlSettingsUnique (See Table 17-9)
Access Read-write

BIOS Setup Control User Password Control Status

Name bSUCuserPasswordControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.33
Description Defines the status of the user password control.
Syntax DellStatus
Access Read-only

BIOS Setup Control User Password Verify Name

Name bSUCuserPasswordVerifyName
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.34
Description Defines the setup BIOS name of the current user password.
Syntax DellString
Access Read-write

BIOS Setup Control User Password New Password Name

Name bSUCuserPasswordNewPasswordName
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.35
Description Defines the setup BIOS name of the new user password. To set a
new user password, a you must have successfully set the current
user password immediately preceding this password change.
Syntax DellString
Access Read-write

402 BIOS Setup Control Group


book.book Page 403 Monday, March 14, 2011 3:01 PM

BIOS Setup Control TPM Security Control Capabilities


Name bSUCtpmSecurityControlCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.36
Description Defines the BIOS setup control capabilities of Trusted Platform
Module (TPM) security.
Syntax DellTPMSecurityControlCapabilities
Access Read-only

BIOS Setup Control TPM Security Control Setting


Name bSUCtpmSecurityControlSetting
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.37
Description Defines the BIOS setup control setting of Trusted Platform
Module (TPM) security.
Syntax DellTPMSecurityControlSetting
Access Read-only

BIOS Setup Control TPM Security Control Status


Name bSUCtpmSecurityControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.38
Description Defines the BIOS setup control status of Trusted Platform
Module (TPM) security.
Syntax DellStatus
Access Read-only

BIOS Setup Control TPM Security Control Name


Name bSUCtpmSecurityControlName
Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.39
Description Defines the BIOS setup control name of Trusted Platform
Module (TPM) security.
Syntax DellString
Access Read-only

BIOS Setup Control Group 403


book.book Page 404 Monday, March 14, 2011 3:01 PM

SCSI Control Table

Name sCSIControlTable
Object ID 1.3.6.1.4.1.674.10892.1.1400.20
Description Defines the Small Computer System Interface (SCSI) Control Table.
Syntax SCSIControlTableEntry
Access Not accessible

SCSI Control Table Entry

Name sCSIControlTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1
Description Defines the SCSI Control Table entry.
Syntax SCSIControlTableEntry
Access Not accessible
Index sCSIControlchassisIndex, sCSIControlIndex

SCSI Control Chassis Index

Name sCSIControlchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

SCSI Control Index

Name sCSIControlIndex
Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.2
Description Defines the index (one-based) of the SCSI controller in this chassis.
Syntax DellObjectRange
Access Read-only

404 BIOS Setup Control Group


book.book Page 405 Monday, March 14, 2011 3:01 PM

SCSI Control Capabilities

Name sCSIControlCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.3
Description Defines the capabilities of the SCSI controller.
Syntax DellStateCapabilities
Access Read-only

SCSI Control Settings

Name sCSIControlSettings
Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.4
Description Defines the state of the SCSI controller.
Syntax DellStateSettings
Access Read-only

SCSI Control Status

Name sCSIControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.5
Description Defines the status of the SCSI controller.
Syntax DellStatus
Access Read-only

SCSI Control Name

Name sCSIControlName
Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.6
Description Defines the setup BIOS name of the SCSI controller.
Syntax DellString
Access Read-only

BIOS Setup Control Group 405


book.book Page 406 Monday, March 14, 2011 3:01 PM

Parallel Port Control Table

Name parallelPortControlTable
Object ID 1.3.6.1.4.1.674.10892.1.1400.30
Description Defines the Parallel Port Control Table.
Syntax ParallelPortControlTableEntry
Access Not accessible

Parallel Port Control Table Entry

Name parallelPortControlTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1
Description Defines the Parallel Port Control Table entry.
Syntax ParallelPortControlTableEntry
Access Not accessible
Index parallelPortControlchassisIndex, parallelPortControlIndex

Parallel Port Control Chassis Index

Name parallelPortControlchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Parallel Port Control Index

Name parallelPortControlIndex
Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.2
Description Defines the index (one-based) of the parallel port in this chassis.
Syntax DellObjectRange
Access Read-only

406 BIOS Setup Control Group


book.book Page 407 Monday, March 14, 2011 3:01 PM

Parallel Port Control Capabilities Unique

Name parallelPortControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.3
Description Defines the capabilities of the parallel port.
Syntax DellParallelPortControlCapabilitiesUnique (See Table 17-12)
Access Read-only

Parallel Port Control Settings Unique

Name parallelPortControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.4
Description Defines the state of the parallel port.
Syntax DellParallelPortControlSettingsUnique (See Table 17-13)
Access Read-only

Parallel Port Control Status

Name parallelPortControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.5
Description Defines the status of the parallel port.
Syntax DellStatus
Access Read-only

Parallel Port Control Name

Name parallelPortControlName
Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.6
Description Defines the setup BIOS name of the parallel port.
Syntax DellString
Access Read-only

BIOS Setup Control Group 407


book.book Page 408 Monday, March 14, 2011 3:01 PM

Parallel Port Control Mode Capabilities Unique

Name parallelPortControlModeCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.7
Description Defines the mode capabilities of the parallel port.
Syntax DellParallelPortControlModeCapabilitiesUnique (See Table 17-14)
Access Read-only

Parallel Port Control Mode Settings Unique

Name parallelPortControlModeSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.8
Description Defines the mode settings of the parallel port.
Syntax DellParallelPortControlModeSettingsUnique (See Table 17-14)
Access Read-write

Serial Port Control Table

Name serialPortControlTable
Object ID 1.3.6.1.4.1.674.10892.1.1400.40
Description Defines the Serial Port Control Table.
Syntax SerialPortControlTableEntry
Access Not accessible

Serial Port Control Table Entry

Name serialPortControlTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1
Description Defines the Serial Port Control Table entry.
Syntax SerialPortControlTableEntry
Access Not accessible
Index serialPortControlchassisIndex, serialPortControlIndex

408 BIOS Setup Control Group


book.book Page 409 Monday, March 14, 2011 3:01 PM

Serial Port Control Chassis Index

Name serialPortControlchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.1
Description Defines index (one-based) of this chassis.
Syntax DellObjectRange
Access read-only

Serial Port Control Index

Name serialPortControlIndex
Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.2
Description Defines the index (one-based) of the serial port in this chassis.
Syntax DellObjectRange
Access read-only

Serial Port Control Capabilities Unique

Name serialPortControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.3
Description Defines the capabilities of the serial port.
Syntax DellSerialPortControlCapabilitiesUnique (See Table 17-15)
Access Read-only

Serial Port Control Settings Unique

Name serialPortControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.4
Description Defines the settings of the serial port.
Syntax DellSerialPortControlSettingsUnique (See Table 17-16)
Access Read-only

BIOS Setup Control Group 409


book.book Page 410 Monday, March 14, 2011 3:01 PM

Serial Port Control Status

Name serialPortControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.5
Description Defines the status of the serial port.
Syntax DellStatus
Access Read-only

Serial Port Control Name

Name serialPortControlName
Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.6
Description Defines the setup BIOS name of the serial port.
Syntax DellString
Access Read-only

USB Control Table


These objects enable you to track the attributes of your Universal Serial Bus (USB).

Name usbControlTable
Object ID 1.3.6.1.4.1.674.10892.1.1400.50
Description Defines the USB Table.
Syntax UsbControlTableEntry
Access Not accessible

USB Control Table Entry

Name usbControlTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1
Description Defines the USB Table entry.
Syntax UsbControlTableEntry
Access Not accessible
Index usbControlchassisIndex, usbControlIndex

410 BIOS Setup Control Group


book.book Page 411 Monday, March 14, 2011 3:01 PM

USB Control Chassis Index

Name usbControlchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.1
Description Defines index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

USB Control Index

Name usbControlIndex
Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.2
Description Defines the index (one-based) of the USB in this chassis.
Syntax DellObjectRange
Access Read-only

USB Control Capabilities

Name usbControlCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.3
Description Defines the capabilities of the USB.
Syntax DellStateCapabilities
Access Read-only

USB Control Settings

Name usbControlSettings
Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.4
Description Defines the control settings for the USB.
Syntax DellStateSettings
Access Read-only

BIOS Setup Control Group 411


book.book Page 412 Monday, March 14, 2011 3:01 PM

USB Control Status

Name usbControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.5
Description Defines the status of the USB.
Syntax DellStatus
Access Read-only

USB Control Name

Name usbControlName
Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.6
Description Defines the setup BIOS name of the USB.
Syntax DellString
Access Read-only

IDE Control Table


These objects enable you to track the attributes of Integrated Device
Electronics (IDE) controller cards in your system.

Name ideControlTable
Object ID 1.3.6.1.4.1.674.10892.1.1400.60
Description Defines the IDE Control Table.
Syntax IdeControlTableEntry
Access Not accessible

IDE Control Table Entry

Name ideControlTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1
Description Defines the IDE Control Table entry.
Syntax IdeControlTableEntry
Access Not accessible
Index ideControlchassisIndex, ideControlIndex

412 BIOS Setup Control Group


book.book Page 413 Monday, March 14, 2011 3:01 PM

IDE Control Chassis Index

Name ideControlchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

IDE Control Index

Name ideControlIndex
Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.2
Description Defines the index (one-based) of the IDE controller in this chassis.
Syntax DellObjectRange
Access Read-only

IDE Control Capabilities Unique

Name ideControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.3
Description Defines the capabilities of the IDE controller.
Syntax DellideControlCapabilitiesUnique (See Table 17-17)
Access Read-only

IDE Control Settings Unique

Name ideControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.4
Description Defines the settings for the IDE controller.
Syntax DellideControlCapabilitiesUnique (See Table 17-17)
Access Read-only

BIOS Setup Control Group 413


book.book Page 414 Monday, March 14, 2011 3:01 PM

IDE Control Status

Name ideControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5
Description Defines the status for the IDE controller.
Syntax DellStatus
Access Read-only

IDE Control Name

Name ideControlName
Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.6
Description Defines the setup BIOS name for the IDE controller.
Syntax DellStatus
Access Read-only

Diskette Control Table

Name disketteControlTable
Object ID 1.3.6.1.4.1.674.10892.1.1400.70
Description Defines the Diskette Control Table.
Syntax DisketteControlTableEntry
Access Not accessible

Diskette Control Table Entry

Name disketteControlTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1
Description Defines the Diskette Control Table entry.
Syntax DellStatus
Access Not accessible
Index disketteControlchassisIndex, disketteControlIndex

414 BIOS Setup Control Group


book.book Page 415 Monday, March 14, 2011 3:01 PM

Diskette Control Chassis Index

Name disketteControlchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Diskette Control Index

Name disketteControlIndex
Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.2
Description Defines the index of the diskette controllers in this chassis.
Syntax DellObjectRange
Access Read-only

Diskette Control Capabilities Unique

Name disketteControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.3
Description Defines the capabilities of the diskette controller.
Syntax DellDisketteControlCapabilitiesUnique (See Table 17-18)
Access Read-only

Diskette Control Settings Unique

Name disketteControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.4
Description Defines the control settings for the diskette controller.
Syntax DellDisketteControlSettingsUnique
Access Read-only

BIOS Setup Control Group 415


book.book Page 416 Monday, March 14, 2011 3:01 PM

Diskette Control Status

Name disketteControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.5
Description Defines the status of the diskette controller.
Syntax DellStatus
Access Read-only

Diskette Control Name

Name disketteControlName
Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.6
Description Defines the setup BIOS name of the diskette controller.
Syntax DellString
Access Read-only

Network Interface Control Table


These MIB objects enable you to track the attributes of the NIC card for your
system.

Name networkInterfaceControlTable
Object ID 1.3.6.1.4.1.674.10892.1.1400.80
Description Defines the Network Interface Control Table.
Syntax NetworkInterfaceControlTableEntry
Access Not accessible

416 BIOS Setup Control Group


book.book Page 417 Monday, March 14, 2011 3:01 PM

Network Interface Control Table Entry

Name networkInterfaceControlTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1
Description Defines the Network Interface Control Table entry.
Syntax NetworkInterfaceControlTableEntry
Access Not accessible
Index networkInterfaceControlchassisIndex,
networkInterfaceControlIndex

Network Interface Control Chassis Index

Name networkInterfaceControlchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Network Interface Control Index

Name networkInterfaceControlIndex
Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.2
Description Defines the index (one-based) of the network interface
controller in this chassis.
Syntax DellObjectRange
Access Read-only

BIOS Setup Control Group 417


book.book Page 418 Monday, March 14, 2011 3:01 PM

Network Interface Control Capabilities Unique

Name networkInterfaceControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.3
Description Defines the capabilities of the NIC.
Syntax DellNetworkInterfaceControlCapabilitiesUnique (See Table 17-19)
Access Read-only

Network Interface Control Settings Unique

Name networkInterfaceControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.4
Description Defines the control settings for the NIC.
Syntax DellNetworkInterfaceControlSettingsUnique (See Table 17-20)
Access Read-write

Network Interface Control Status

Name networkInterfaceControlStatus
Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.5
Description Defines the status of the NIC.
Syntax DellStatus
Access Read-only

Network Interface Control Name

Name networkInterfaceControlName
Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.6
Description Defines the setup BIOS name of the NIC.
Syntax DellString
Access Read-only

418 BIOS Setup Control Group


book.book Page 419 Monday, March 14, 2011 3:01 PM

BIOS Group Variable Values


This section includes definitions for server administrator-specific variable
values used in this section.

Table 17-1. Speaker Control Capabilities Unique

Variable Name: DellSpeakerControlCapabilitiesUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Speaker control capabilities are unknown.
enableCapable(2) Setup BIOS can enable speaker control.
lowCapable(4) Setup BIOS can set the speaker volume to low.
mediumCapable(8) Setup BIOS can set the speaker volume to medium.
highCapable(16) Setup BIOS can set the speaker volume to high.
allVolumeCapable(30) Setup BIOS can set the speaker volume to any of the
three settings.

Table 17-2. Speaker Control Settings Unique

Variable Name: DellSpeakerControlSettingsUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Speaker control state is unknown.
enabled(2) Speaker control is enabled.
low(4) Speaker control volume is low.
medium(8) Speaker control volume is medium.
high(16) Speaker control volume is high.

BIOS Setup Control Group 419


book.book Page 420 Monday, March 14, 2011 3:01 PM

Table 17-3. Network Interface (NIF) Wakeup on LAN Capabilities Unique

Variable Name: DellNIFwakeonLanControlCapabilitiesUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Setup BIOS Wakeup on LAN
capabilities are unknown.
enableCapable(2) Setup BIOS is capable of enabling the
NIF Wakeup on LAN.
addInCardCapable(4) Setup BIOS is capable of enabling
Wakeup on LAN by option card.
onBoardCapable(8) Setup BIOS is capable of enabling
Wakeup on LAN by integrated NIF.
bothCapable(14) Setup BIOS is capable of enabling
Wakeup on LAN by either option card or
integrated NIF.

Table 17-4. NIF Wakeup on LAN Control Settings Unique

Variable Name: DellNIFwakeonLanControlSettingsUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) NIF Wakeup on LAN state is unknown.
enabled(2) NIF Wakeup on LAN is enabled.
addInCard(4) NIF Wakeup on LAN is by option card.
onBoard(8) NIF Wakeup on LAN is by integrated NIF.
addInCardOrOnBoard(12) NIF Wakeup on LAN is by option card or
integrated NIF.

420 BIOS Setup Control Group


book.book Page 421 Monday, March 14, 2011 3:01 PM

Table 17-5. Boot Sequence Control Capabilities Unique

Variable Name: DellBootSequenceControlCapabilitiesUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
bootSequenceUnknown(1) Boot sequence capabilities are unknown.
bootFromDisketteFirstCapable Setup BIOS can boot from a diskette
(2) first.
bootFromhardDriveFirstCapable Setup BIOS can boot from an IDE hard
(4) drive first.
bootFromDisketteORHardDrive Setup BIOS can boot from a diskette or
FirstCapable(6) an IDE hard drive first.
bootFromDeviceListCapable(8) Setup BIOS can boot from a device list.
bootFromCDROMFirstCapable(16) Setup BIOS can boot from a CD first.
allFirstCapable(30) Setup BIOS can boot by any of the
preceding methods first.

Table 17-6. Boot Sequence Control Settings Unique

Variable Name: DellBootSequenceControlSettingsUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
bootSequenceUnknown(1) Boot sequence state is unknown.
bootFromDisketteFirst(2) Setup BIOS is set to boot by
diskette first.
bootFromHardDriveFirst(4) Setup BIOS is set to boot by IDE
hard drive first.
bootFromDeviceList(8) Setup BIOS is set to boot by a
device list.
bootFromCDROMFirst(16) Setup BIOS is set to boot by CD
first.

BIOS Setup Control Group 421


book.book Page 422 Monday, March 14, 2011 3:01 PM

Table 17-7. BIOS Password Control Capabilities

Variable Name: DellBIOSPasswordControlCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
passwordControlCapabilitiesUn BIOS password capabilities are
known(1) unknown.
passwordControlEnableCapable Setup BIOS is capable of enabling
(2) password changes.
passwordControlJumperDisable Setup BIOS is capable of
Capable(4) determining if password control can
be jumper disabled.
passwordControlEnableANDJumper Setup BIOS is capable of enabling
DisableCapable(6) password changes and of
determining if password control can
be jumper disabled.

Table 17-8. BIOS Password Control Settings Unique

Variable Name: DellBIOSPasswordControlSettingsUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
passwordControlSettingsUnknown(1) Setup BIOS password state is
unknown.
passwordControlEnabled(2) Setup BIOS has password changes
enabled.
passwordControlJumperDisabled(4) Setup BIOS has determined that
password control has been disabled
by a jumper.

422 BIOS Setup Control Group


book.book Page 423 Monday, March 14, 2011 3:01 PM

Table 17-9. BIOS Password Control Settings

Variable Name: DellBIOSPasswordControlSettingsUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
passwordControlSettingsUnknown(1) Setup BIOS password state is
unknown.
passwordControlEnabled(2) Setup BIOS has password changes
enabled.
passwordControlJumperDisabled(4) Setup BIOS has determined that
password control has been
disabled by a jumper.

Table 17-10. TPM Security Control Capabilities

Variable Name: DellTPMSecurityControlCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
offCapable(1) TPM security can be Off.
onWithPrebootMeasurementsCap TPM security can be On with Pre-boot
able(2) Measurements.
onWithoutPrebootMeasurements TPM security can be On without Pre-boot
Capable(4) Measurements.

Table 17-11. TPM Security Control Setting

Variable Name: DellTPMSecurityControlSetting


Data Type: Integer
Possible Data Values Meaning of Data Value
off(0) TPM security is Off.
onWithPrebootMeasurements(1) TPM security is On with Pre-boot
Measurements.
onWithoutPrebootMeasurements TPM security is On without Pre-boot
(2) Measurements.

BIOS Setup Control Group 423


book.book Page 424 Monday, March 14, 2011 3:01 PM

Table 17-12. Parallel Port Control Capabilities

Variable Name: DellParallelPortControlCapabilitiesUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Setup BIOS parallel port capabilities
are unknown.
enableCapable(2) Setup BIOS can enable the parallel port.
lpt1Capable(4) Setup BIOS can support parallel port 1.
lpt1andEnableCapable(6) Setup BIOS has enabled parallel port 1.
lpt2Capable(8) Setup BIOS can support parallel port 2.
lpt2andEnableCapable(10) Setup BIOS has enabled parallel port 2.
lpt3Capable(16) Setup BIOS can support parallel port 3.
lpt3andEnableCapable(18) Setup BIOS has enabled parallel port 3.
allParallelPortCapable(30) Setup BIOS can support any of the three
parallel ports.

Table 17-13. Parallel Port Control Settings

Variable Name: DellParallelPortControlSettingsUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Parallel port state is unknown.
enabled(2) Setup BIOS has enabled the parallel port.
lpt1(4) Setup BIOS supports parallel port 1.
lpt1Enabled(6) Setup BIOS has enabled parallel port 1.
lpt2(8) Setup BIOS supports parallel port 2.
lpt2Enabled(10) Setup BIOS has enabled parallel port 2.
lpt3(16) Setup BIOS supports parallel port 3.

424 BIOS Setup Control Group


book.book Page 425 Monday, March 14, 2011 3:01 PM

Table 17-14. Parallel Port Control Mode Settings

Variable Name: DellParallelPortControlModeSettingsUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Parallel port mode is unknown.
atModeEnabled(2) Setup BIOS has set the parallel port to AT mode.
ps2ModeEnabled(4) Setup BIOS has set the parallel port to Personal
Systems/2 (PS/2) mode.
ecpModeEnabled(8) Setup BIOS has set the parallel port to Extended
Capabilities Port (ECP) mode.
eppModeEnabled(16) Setup BIOS has set the parallel port to Enhanced
Parallel Port (EPP) mode.

Table 17-15. Serial Port Control Capabilities

Variable Name: DellSerialPortControlCapabilitiesUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Setup BIOS serial port capabilities are
unknown.
enableCapable(2) Setup BIOS can enable the serial port.
com1Capable(4) Setup BIOS can support serial port 1.
enableAndCom1Capable(6) Setup BIOS can enable serial port 1.
com2Capable(8) Setup BIOS can support serial port 2.
enableAndCom2Capable(10) Setup BIOS is capable of enabling serial port 2.
com3Capable(16) Setup BIOS can support serial port 3.
enableAndCom3Capable(18) Setup BIOS is capable of enabling serial port 3.
com4Capable(32) Setup BIOS can support serial port 4.
enableAndCom4Capable(34) Setup BIOS is capable of enabling serial port 4.
autoConfigCapable(64) Setup BIOS is capable of autoconfiguring all
serial ports.

BIOS Setup Control Group 425


book.book Page 426 Monday, March 14, 2011 3:01 PM

Table 17-15. Serial Port Control Capabilities (continued)

Variable Name: DellSerialPortControlCapabilitiesUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
com1OrCom3CapableAndAuto Setup BIOS has enabled autoconfiguration of
ConfigCapable(86) COM1 and COM3 serial ports.
com2OrCom4CapableAndAuto Setup BIOS has enabled autoconfiguration of
ConfigCapable(106) COM2 and COM4 serial ports.
allcomCapable(126) Setup BIOS is capable of enabling or
autoconfiguring all serial ports.

Table 17-16. Serial Port Control Settings

Variable Name: DellSerialPortControlSettingsUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Serial port state is unknown.
enabled(2) Setup BIOS has enabled the serial port.
com1(4) Setup BIOS has selected serial port 1.
com1Enabled(6) Setup BIOS has enabled serial port 1.
com2(8) Setup BIOS has selected serial port 2.
com2Enabled(10) Setup BIOS has enabled serial port 2.
com3(16) Setup BIOS has selected serial port 3.
com3Enabled(18) Setup BIOS has enabled serial port 3.
com4(32) Setup BIOS has selected serial port 4.
com4Enabled(34) Setup BIOS has enabled serial port 4.
comPortsAutoConfig(64) Setup BIOS has selected autoconfiguration
of serial ports.
enabledAndAutoConfig(66) Setup BIOS has enabled autoconfiguration
of serial ports.

426 BIOS Setup Control Group


book.book Page 427 Monday, March 14, 2011 3:01 PM

Table 17-17. IDE Control Capabilities

Variable Name: DellideControlCapabilitiesUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) IDE control capabilities are unknown.
ideControlAutoConfigOrEnable IDE controller is autoconfigurable or
Capable(2) enable capable.

Table 17-18. Diskette Control Settings

Variable Name: DellDisketteControlSettingsUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Diskette control state is unknown.
disketteControlAutoConfigEnabled Diskette control is set as
OrEnabled(2) autoconfigurable or enabled.

Table 17-19. Network Interface Control Capabilities

Variable Name:
DellNetworkInterfaceControlCapabilitiesUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Unknown setup BIOS network interface
capabilities.
enableCapable(2) Setup BIOS is capable of enabling the
network interface.
enableWithoutPXECapable(4) Setup BIOS is capable of enabling the
NIF without Pre-boot eXecution
Environment (PXE).

BIOS Setup Control Group 427


book.book Page 428 Monday, March 14, 2011 3:01 PM

Table 17-20. Network Interface Control Settings

Variable Name: DellNetworkInterfaceControlSettingsUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Network interface state is unknown.
enabled(2) Network interface is enabled.
enabledWithoutPXE(4) Network interface is enabled without PXE.

428 BIOS Setup Control Group


book.book Page 429 Monday, March 14, 2011 3:01 PM

18
Local Response Agent Group
The Local Response Agent Group provides information about various
attributes of your system’s local response agent (LRA). The LRA allows
systems managers to predetermine how a system running the server
administrator responds to a particular event type, such as the loss of
redundancy in a specific component or the elevation of temperature in a
chassis. Systems managers can configure the LRA to respond to an event type
with a specific action. When the condition of the critical component worsens,
the systems manager can escalate the response to make it more obvious to the
operator.
For example, when a voltage probe on a monitored machine reaches a
warning condition, the systems manager may want to notify the operator by
causing the machine to beep. When the voltage probe reaches failure, the
systems manager might want to have the system that has a failing component
send a broadcast message to the management system and power off the
troubled system.

LRA Group Tables


The following management information base (MIB) tables define
LRA variable attributes:
• "LRA Global Settings Table" on page 430
• "LRA Action Table" on page 432

LRA Global Settings


The global settings table allows the systems manager to determine what
LRA capabilities exist for a specific system that is running Server Administrator.
Some machines may support all or some of the capabilities described in
DellLocalResponseAgentCapabilitiesUnique. The LRA Global Settings Table
also defines thermal shutdown capabilities and settings. In the event that a
temperature probe determines the temperature is at or over the failure limit,
the systems manager can set an action to be taken automatically.

Local Response Agent Group 429


book.book Page 430 Monday, March 14, 2011 3:01 PM

LRA Global Settings Table

Name lRAGlobalSettingsTable
Object ID 1.3.6.1.4.1.674.10892.1.1500.10
Description Defines the LRA Global Settings Table.
Syntax SEQUENCE OF LRAGlobalSettingsTableEntry
Access Not accessible

LRA Global Settings Table Entry

Name lRAGlobalSettingsTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1
Description Defines the LRA Global Settings Table entry.
Syntax LRAGlobalSettingsTableEntry
Access Not accessible
Index lRAGlobalchassisIndex

LRA Global Chassis Index

Name lRAGlobalchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

LRA Global State

Name lRAGlobalState
Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.2
Description Defines the state of the LRA global settings.
Syntax DellStateSettings
Access Read-only

430 Local Response Agent Group


book.book Page 431 Monday, March 14, 2011 3:01 PM

LRA Global Settings Disable Time-out Value

Name lRAGlobalSettingsDisableTimeoutValue
Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.3
Description Defines the time-out duration countdown, in seconds, that the
LRA global settings are disabled after a system shutdown and reboot.
Syntax DellUnsigned32BitRange
Access Read-only

LRA Global Settings Capabilities Unique

Name lRAGlobalSettingsCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.4
Description Defines the set of global capabilities that all local response
agents may or may not allow to be set or reset.
Syntax DellLocalResponseAgentCapabilitiesUnique (See Table 18-1)
Access Read-only

LRA Global Thermal Shutdown Capabilities Unique

Name lRAGlobalThermalShutdownCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.5
Description Defines the set of thermal shutdown capabilities that are
supported by the LRA.
Syntax DellLRAThermalShutdownCapabilitiesUnique
Access Read-only

LRA Global Thermal Shutdown State Settings Unique

Name lRAGlobalThermalShutdownStateSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.6
Description Defines the set of thermal shutdown state and settings that the
local response agent supports.
Syntax DellLRAThermalShutdownStateSettingsUnique
Access Read-write

Local Response Agent Group 431


book.book Page 432 Monday, March 14, 2011 3:01 PM

LRA Action Table


The DellLocalResponseAgentCapabilitiesUnique variable in the
global action table defines the capabilities that are allowed for a particular
system. The LRA Action Table that follows selects which of the system’s
capabilities (global actions) are to be enabled.

Name lRAActionTableTable
Object ID 1.3.6.1.4.1.674.10892.1.1500.20
Description Defines the LRA Action Table.
Syntax SEQUENCE OF LRAActionTableTableEntry
Access Not accessible

LRA Action Table Entry

Name lRAActionTableTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1
Description Defines the LRA Action Table entry.
Syntax LRAActionTableTableEntry
Access Not accessible
Index lRAActionTablechassisIndex,
lRAActionTableActionNumberIndex

LRA Action Table Chassis Index

Name lRAActionTablechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

432 Local Response Agent Group


book.book Page 433 Monday, March 14, 2011 3:01 PM

LRA Action Table Action Number Index

Name lRAActionTableActionNumberIndex
Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.2
Description Defines the LRA action number index. The action number indexes
are as follows:
• 160 — temperature failure action definition
• 168 — cooling device failure action definition
• 172 — voltage failure action definition
• 200 — temperature warning action definition
• 202 — voltage warning action definition
• 204 — cooling device warning action definition
• 206 — amperage failure action definition
• 208 — amperage warning action definition
• 210 — a power or cooling unit redundancy lost action definition
• 212 — a power or cooling unit redundancy degraded action definition
• 214 — power supply failed action definition
• 220 — chassis intrusion action definition
• 228 — memory device warning action definition
• 474 — memory device failure action definition
• 1006 — automatic system recovery (ASR) action definition
• 1353 — power supply warning action definition
• 1553 — log near full action definition
• 1554 — log full action definition
• 1603 — processor warning action definition
• 1604 — processor failure action definition
• 1703 — battery warning action definition
• 1704 — battery failure action definition
Syntax DellUnsigned16BitRange
Access Read-only

Local Response Agent Group 433


book.book Page 434 Monday, March 14, 2011 3:01 PM

LRA Action Table User Application Name

Name lRAActionTableUserApplicationName
Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.3
Description When the execute application value is set, provides the following
user-assignable LRA information:
• Name of the user application executable path
• File name to execute
Syntax DisplayString (SIZE (0..256)
Access Read-write

LRA Action Table Settings Unique

Name lRAActionTableSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.4
Description Defines the LRA settings.
Syntax DellLocalResponseAgentSettingsUnique (See Table 18-3)
Access Read-write

Local Response Agent Variable Values


This section includes definitions for server administrator-specific variable
values used in this section.

Table 18-1. LRA Capabilities Definitions

Variable Name: DellLocalResponseAgentCapabilitiesUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
speakerControlCapable(1) The LRA can issue a speaker beep.
consoleAlertCapable(2) The LRA can alert the console.
broadcastMessageCapable(4) The LRA can broadcast a message.
osShutDownCapable(8) The LRA can shut down the operating
system.

434 Local Response Agent Group


book.book Page 435 Monday, March 14, 2011 3:01 PM

Table 18-1. LRA Capabilities Definitions (continued)

Variable Name: DellLocalResponseAgentCapabilitiesUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
rebootCapable(16) The LRA can reboot the system.
powerCycleCapable(32) The LRA is capable of a system power
cycle.
powerOFFCapable(64) The LRA can shut the system power off.
executeApplicationCapable(256) The LRA can execute a user mode
application.
lraFullyCapable(383) The LRA has all of the preceding
capabilities.

Table 18-2. LRA Thermal Shutdown Capabilities Unique

Variable Name: DellLRAThermalShutdownCapabilitiesUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The LRA has no thermal shutdown
capabilities.
Unknown capabilities(1) The LRA’s thermal shutdown capabilities are
unknown.
enableCapable(2) The LRA can be disabled (offline, a binary
0 value) or enabled (online, a binary 1 value).
warningCapable(4) The LRA can carry out chassis-determined
action(s) when a warning condition is
detected.
enableOnWarningCapable(6) The LRA enables activation of chassis-
determined action(s) when a warning
condition is detected.
failureCapable(8) The LRA can carry out chassis-determined
action(s) when a failure condition is detected.

Local Response Agent Group 435


book.book Page 436 Monday, March 14, 2011 3:01 PM

Table 18-2. LRA Thermal Shutdown Capabilities Unique (continued)

Variable Name: DellLRAThermalShutdownCapabilitiesUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
enableOnFailureCapable(10) The LRA enables activation of chassis-
determined action(s) when a failure condition
is detected.
enableOnWarningOrFailure The LRA enables activation of chassis-
Capable(14) determined action(s) when either a failure or a
warning condition is detected.

Table 18-3. Local Response Agent Settings Unique

Variable Name: DellLocalResponseAgentSettingsUnique


Data Type: Integer
Possible Data Values Meaning of Data Value
speakerControl(1) LRA is set to issue a speaker beep.
consoleAlert(2) LRA is set to issue a console alert.
broadcastMessage(4) LRA is set to issue a broadcast message.
osShutDown(8) LRA is set to issue an operating system shutdown.
reboot(16) LRA is set to issue a system reboot.
powerCycle(32) LRA is set to issue a system power cycle.
powerOFF(64) LRA is set to issue a system power off.
executeApplication(256) LRA is set to start a user mode application.
allLRASettingsUnique(383) LRA is set to all LRA settings combinations.

436 Local Response Agent Group


book.book Page 437 Monday, March 14, 2011 3:01 PM

19
Cost of Ownership Group
The Cost of Ownership (COO) Group provides a full set of cost-tracking
objects, including fields for the computer’s manufacturer, insurer, lessor,
warranty, user, trouble tickets, and many others. You can use these management
information base (MIB) objects to obtain accurate and complete
measurements of the cost of each computer asset in your organization.

Cost of Ownership Group Tables


The Cost of Ownership Group defines objects in the following MIB tables:
• "Cost of Ownership Table" on page 437
• "COO Service Contract Table" on page 448
• "COO Cost Event Log Table" on page 450
• "COO Warranty Table" on page 452
• "COO Lease Information Table" on page 454
• "COO Schedule Number Table" on page 457
• "COO Options Table" on page 458
• "COO Maintenance Table" on page 460
• "COO Repair Table" on page 462
• "COO Support Information Table" on page 464
• "COO Trouble Ticket Table" on page 466

Cost of Ownership Table


The following MIB object sets up the Cost of Ownership Table.

Name cooTable
Object ID 1.3.6.1.4.1.674.10892.1.1600.10
Description Defines the Cost of Ownership Table.
Syntax SEQUENCE OF CooTableEntry
Access Not accessible

Cost of Ownership Group 437


book.book Page 438 Monday, March 14, 2011 3:01 PM

Cost of Ownership Table Entry

Name cooTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1
Description Defines the Cost of Ownership Table entry.
Syntax CooTableEntry
Access Not accessible
Index coochassisIndex

COO Chassis Index

Name coochassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax CooTableEntry
Access Read-only

COO State

Name cooState
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.2
Description Defines the acquisition state of the system.
Syntax DellStateSettings
Access Read-only

COO Acquisition Purchase Cost

Name cooAquisitionPurchaseCost
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.3
Description Defines the purchase cost of the system.
Syntax DellUnsigned32BitRange
Access Read-write

438 Cost of Ownership Group


book.book Page 439 Monday, March 14, 2011 3:01 PM

COO Acquisition Waybill Number

Name cooAquisitionWayBillNumber
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.4
Description Defines the waybill number of the system.
Syntax DellUnsigned32BitRange
Access Read-write

COO Acquisition Install Date Name

Name cooAquisitionInstallDateName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.5
Description Defines the installation date and time for the system.
Syntax DellDateName
Access Read-write

COO Acquisition Purchase Order

Name cooAquisitionPurchaseOrder
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.6
Description Defines the purchase order number of the system.
Syntax DellUnsigned32BitRange
Access Read-write

COO Acquisition Purchase Date Name

Name cooAquisitionPurchaseDateName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.7
Description Defines the purchase date and time of the system.
Syntax DellDateName
Access Read-write

Cost of Ownership Group 439


book.book Page 440 Monday, March 14, 2011 3:01 PM

COO Acquisition Signing Authority Name

Name cooAquisitionSigningAuthorityName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.8
Description Defines the name of the authorized person who signs for the
system.
Syntax DellCostofOwnershipString
Access Read-write

COO Original Machine Configuration Expensed

Name cooOriginalMachineConfigurationExpensed
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.9
Description Specifies whether the purchase of this system was expensed.
Syntax DellBoolean
Access Read-write

COO Original Machine Configuration Vendor Name

Name cooOriginalMachineConfigurationVendorName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.10
Description Defines the vendor name of the system.
Syntax DellCostofOwnershipString
Access Read-only

COO Cost Center Information Vendor Name

Name cooCostCenterInformationVendorName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.11
Description Defines the cost center name of the system.
Syntax DellCostofOwnershipString
Access Read-write

440 Cost of Ownership Group


book.book Page 441 Monday, March 14, 2011 3:01 PM

COO User Information User Name

Name cooUserInformationUserName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.12
Description Defines the name of the user for this system.
Syntax DellCostofOwnershipString
Access Read-write

COO Extended Warranty Start Date Name

Name cooExtendedWarrantyStartDateName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.13
Description Defines the extended warranty start date for this system.
Syntax DellDateName
Access Read-write

COO Extended Warranty End Date Name

Name cooExtendedWarrantyEndDateName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.14
Description Defines the extended warranty end date for this system.
Syntax DellDateName
Access Read-write

COO Extended Warranty Cost

Name cooExtendedWarrantyCost
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.15
Description Defines the extended warranty cost date for this system.
Syntax DellUnsigned32BitRange
Access Read-write

Cost of Ownership Group 441


book.book Page 442 Monday, March 14, 2011 3:01 PM

COO Extended Warranty Provider Name

Name cooExtendedWarrantyProviderName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16
Description Defines the name of the extended warranty provider for this
system.
Syntax DellCostofOwnershipString
Access Read-write

COO Ownership Code

Name cooOwnershipCode
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.17
Description Defines the ownership code for this system.
Syntax DellCooOwnershipCodes (See Table 19-1)
Access Read-write

COO Corporate Owner Name

Name cooCorporateOwnerName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.18
Description Defines the name of the corporation that owns this system.
Syntax DellCostofOwnershipString
Access Read-write

COO Hazardous Waste Code Name

Name cooHazardousWasteCodeName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.19
Description Defines the hazardous waste code for this system.
Syntax DellCostofOwnershipString
Access Read-write

442 Cost of Ownership Group


book.book Page 443 Monday, March 14, 2011 3:01 PM

COO Deployment Date Length

Name cooDeploymentDateLength
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.20
Description Defines the deployment time for this system.
Syntax DellUnsigned32BitRange
Access Read-write

COO Deployment Duration Type

Name cooDeploymentDurationType
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21
Description Defines the deployment time units for this system.
Syntax DellCooHourDayDurationType (See Table 19-2)
Access Read-write

COO Training Name

Name cooTrainingName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.22
Description Defines the training that the user has for this system.
Syntax DellCostofOwnershipString
Access Read-write

COO Outsourcing Problem Description Name

Name cooOutsourcingProblemDescriptionName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.23
Description Defines a problem encountered with the outsourcing service
provider.
Syntax DellCostofOwnershipString
Access Read-write

Cost of Ownership Group 443


book.book Page 444 Monday, March 14, 2011 3:01 PM

COO Outsourcing Service Fee Name

Name cooOutsourcingServiceFeeName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.24
Description Defines amount that the outsourcing vendor charges for service.
Syntax DellCostofOwnershipString
Access Read-write

COO Outsourcing Signing Authority Name

Name cooOutsourcingSigningAuthorityName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.25
Description Defines the name of the person who can sign the authorization for
service.
Syntax DellCostofOwnershipString
Access Read-write

COO Outsourcing Provider Fee Name

Name cooOutsourcingProviderFeeName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.26
Description Defines any additional outsourcing charge for service.
Syntax DellCostofOwnershipString
Access Read-write

COO Outsourcing Provider Service Level Name

Name cooOutsourcingProviderServiceLevelName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.27
Description Defines the service level agreement for the system.
Syntax DellCostofOwnershipString
Access Read-write

444 Cost of Ownership Group


book.book Page 445 Monday, March 14, 2011 3:01 PM

COO Insurance Company Name

Name cooInsuranceCompanyName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.28
Description Defines the name of the company that insures this system.
Syntax DellCostofOwnershipString
Access Read-write

COO Box Asset Tag Name

Name cooBoxAssetTagName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.29
Description Defines the name of the asset tag.
Syntax DellCostofOwnershipString
Access Read-write

COO Box System Name

Name cooBoxSystemName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.30
Description Defines the name of the system.
Syntax DellCostofOwnershipString
Access Read-write

COO Box Central Processing Unit (CPU) Serial Number Name

Name cooBoxCPUSerialNumberName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.31
Description Defines the name of the CPU serial number for the system.
Syntax DellCostofOwnershipString
Access Read-write

Cost of Ownership Group 445


book.book Page 446 Monday, March 14, 2011 3:01 PM

COO Operating System Upgrade Type Name

Name cooOperatingSystemUpgradeTypeName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.32
Description Defines the name of the operating system on this system.
Syntax DellCostofOwnershipString
Access Read-write

COO Operating System Upgrade Patch Level Name

Name cooOperatingSystemUpgradePatchLevelName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.33
Description Defines the name of the operating system patch level for this
system.
Syntax DellCostofOwnershipString
Access Read-write

COO Operating System Upgrade Date

Name cooOperatingSystemUpgradeDate
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.34
Description Defines the upgrade file date for this operating system.
Syntax DellCostofOwnershipString
Access Read-write

COO Depreciation Duration

Name cooDepreciationDuration
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.35
Description Defines the length of depreciation for this system.
Syntax DellUnsigned32BitRange
Access Read-write

446 Cost of Ownership Group


book.book Page 447 Monday, March 14, 2011 3:01 PM

COO Depreciation Duration Type

Name cooDepreciationDurationType
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36
Description Defines the unit of time for the depreciation of this system.
Syntax DellCooMonthYearDurationType
Access Read-write

COO Depreciation Percentage

Name cooDepreciationPercentage
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.37
Description Defines the percentage of depreciation for this system.
Syntax DellUnsigned32BitRange
Access Read-write

COO Depreciation Method Name

Name cooDepreciationMethodName
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.38
Description Defines the name of the depreciation method for this system.
Syntax DellCostofOwnershipString
Access Read-write

COO Registration Is Registered

Name cooRegistrationIsRegistered
Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.39
Description Specifies whether this system is registered or not.
Syntax DellBoolean
Access Read-write

Cost of Ownership Group 447


book.book Page 448 Monday, March 14, 2011 3:01 PM

COO Service Contract Table


The service contract table provides MIB objects that help you track the name,
vendor, and type of service contract you have for your system.

Name cooServiceContractTable
Object ID 1.3.6.1.4.1.674.10892.1.1600.20
Description Defines the COO Service Contract Table.
Syntax SEQUENCE OF CooServiceContractTableEntry
Access Not accessible

COO Service Contract Table Entry

Name cooServiceContractTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1
Description Defines the COO Service Contract Table entry.
Syntax CooServiceContractTableEntry
Access Not accessible
Index cooServiceContractchassisIndex, cooServiceContractIndex

COO Service Contract Chassis Index

Name cooServiceContractchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

COO Service Contract Index

Name cooServiceContractIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.2
Description Defines the index (one-based) of this service contract.
Syntax DellObjectRange
Access Read-only

448 Cost of Ownership Group


book.book Page 449 Monday, March 14, 2011 3:01 PM

COO Service Contract State

Name cooServiceContractState
Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.3
Description Defines the status of the service contract for this system.
Syntax DellStateSettings
Access Read-only

COO Service Contract Was Renewed

Name cooServiceContractWasRenewed
Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4
Description Specifies whether the service contract for this system was
renewed.
Syntax DellBoolean
Access Read-write

COO Service Contract Type Name

Name cooServiceContractTypeName
Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.5
Description Defines the name of the service contract type for this system.
Syntax DellCostofOwnershipString
Access Read-write

COO Service Contract Vendor Name

Name cooServiceContractVendorName
Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.6
Description Defines the name of the service contract provider for this
system.
Syntax DellCostofOwnershipString
Access Read-write

Cost of Ownership Group 449


book.book Page 450 Monday, March 14, 2011 3:01 PM

COO Cost Event Log Table


The COO Cost Event Log Table provides MIB objects that allow you to track
the duration and type of events that are logged for a particular system.

Name cooCostEventLogTable
Object ID 1.3.6.1.4.1.674.10892.1.1600.30
Description Defines the COO Cost Event Log Table.
Syntax SEQUENCE OF COO CostEventLogTableEntry
Access Not accessible

COO Cost Event Log Table Entry

Name cooCostEventLogTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1
Description Defines the COO Cost Event Log Table entry.
Syntax cooCostEventLogTableEntry
Access Not accessible
Index cooCostEventLogchassisIndex, cooCostEventLogIndex

COO Cost Event Log Chassis Index

Name cooCostEventLogchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

COO Cost Event Log Index

Name cooCostEventLogIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.2
Description Defines the index (one-based) of the cost event log.
Syntax DellObjectRange
Access Read-only

450 Cost of Ownership Group


book.book Page 451 Monday, March 14, 2011 3:01 PM

COO Cost Event Log State

Name cooCostEventLogState
Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.3
Description Defines the cost event log state of this system.
Syntax DellStateSettings
Access Read-only

COO Cost Event Log Duration

Name cooCostEventLogDuration
Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.4
Description Defines the duration of the event for this system.
Syntax DellUnsigned32BitRange
Access Read-write

COO Cost Event Log Duration Type

Name cooCostEventLogDurationType
Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.5
Description Defines the duration type of the event for this system.
Syntax DellCOOHourDayDurationType (See Table 19-2)
Access Read-write

COO Cost Event Log Description Name

Name cooCostEventLogDescriptionName
Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.6
Description Defines the name of the event description.
Syntax DellCostofOwnershipString
Access Read-write

Cost of Ownership Group 451


book.book Page 452 Monday, March 14, 2011 3:01 PM

COO Warranty Table


The COO Warranty Table objects enable you to track facts about the type
and duration of the warranty for a particular system.

Name cooWarrantyTable
Object ID 1.3.6.1.4.1.674.10892.1.1600.40
Description Defines the COO Warranty Table.
Syntax SEQUENCE OF CooWarrantyTableEntry
Access Not accessible

COO Warranty Table Entry

Name cooWarrantyTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1
Description Defines the COO Warranty Table entry.
Syntax CooWarrantyTableEntry
Access Not accessible
Index cooWarrantychassisIndex, cooWarrantyIndex

COO Warranty Chassis Index

Name cooWarrantychassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-write

COO Warranty Index

Name cooWarrantyIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.2
Description Defines the index of the warranty for this system.
Syntax DellObjectRange
Access Read-only

452 Cost of Ownership Group


book.book Page 453 Monday, March 14, 2011 3:01 PM

COO Warranty State

Name cooWarrantyState
Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.3
Description Defines the state of the warranty for this system.
Syntax DellStateSettings
Access Read-only

COO Warranty Duration

Name cooWarrantyDuration
Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.4
Description Defines the duration of the warranty.
Syntax DellUnsigned32BitRange
Access Read-write

COO Warranty Duration Type

Name cooWarrantyDurationType
Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.5
Description Defines the warranty duration type for the system.
Syntax DellCOODayMonthDurationType
Access Read-write

COO Warranty End Date Name

Name cooWarrantyEndDateName
Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.6
Description Defines the warranty end date for this system.
Syntax DellDateName
Access Read-write

Cost of Ownership Group 453


book.book Page 454 Monday, March 14, 2011 3:01 PM

COO Warranty Cost

Name cooWarrantyCost
Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.7
Description Defines the cost of the warranty for this system.
Syntax DellUnsigned32BitRange
Access Read-write

COO Lease Information Table


The COO lease information MIB objects enable you to track information
about your lessor, lease duration, and lease type for each system.

Name cooLeaseInformationTable
Object ID 1.3.6.1.4.1.674.10892.1.1600.50
Description Defines the COO Lease Information Table.
Syntax SEQUENCE OF CooLeaseInformationTableEntry
Access Not accessible

COO Lease Information Table Entry

Name cooLeaseInformationTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1
Description Defines the COO Lease Information Table entry.
Syntax CooLeaseInformationTableEntry
Access Not accessible
Index cooLeaseInformationchassisIndex, cooLeaseInformationIndex

COO Lease Information Chassis Index

Name cooLeaseInformationchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

454 Cost of Ownership Group


book.book Page 455 Monday, March 14, 2011 3:01 PM

COO Lease Information Index

Name cooLeaseInformationIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.2
Description Defines the index of the lease information for this system.
Syntax DellObjectRange
Access Read-only

COO Lease Information State

Name cooLeaseInformationState
Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.3
Description Defines the lease information state for this system.
Syntax DellStateSettings
Access Read-write

COO Lease Information Multiple Schedules

Name cooLeaseInformationMultipleSchedules
Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.4
Description Defines whether there are multiple schedules for this lease.
Syntax DellBoolean
Access Read-only

COO Lease Information Buyout Amount

Name cooLeaseInformationBuyOutAmount
Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.5
Description Defines the balance purchase price for this system.
Syntax DellUnsigned32BitRange
Access Read-write

Cost of Ownership Group 455


book.book Page 456 Monday, March 14, 2011 3:01 PM

COO Lease Information Lease Rate Factor

Name cooLeaseInformationLeaseRateFactor
Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.6
Description Defines the rate factor for the lease on this system.
Syntax DellUnsigned32BitRange
Access Read-write

COO Lease Information End Date Name

Name cooLeaseInformationEndDateName
Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.7
Description Defines the end date for the lease on this system.
Syntax DellDateName
Access Read-write

COO Lease Information Fair Market Value

Name cooLeaseInformationFairMarketValue
Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.8
Description Defines the fair market value of this system.
Syntax DellUnsigned32BitRange
Access Read-write

COO Lease Information Lessor Name

Name cooLeaseInformationLessorName
Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.9
Description Defines the name of the lessor of this system.
Syntax DellCostofOwnershipString
Access Read-write

456 Cost of Ownership Group


book.book Page 457 Monday, March 14, 2011 3:01 PM

COO Schedule Number Table

Name cooScheduleNumberTable
Object ID 1.3.6.1.4.1.674.10892.1.1600.60
Description Defines the COO Schedule Number Information Table.
Syntax SEQUENCE OF CooScheduleNumberTableEntry
Access Not accessible

COO Schedule Number Table Entry

Name cooScheduleNumberTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1
Description Defines the COO Schedule Number Information Table entry.
Syntax CooScheduleNumberTableEntry
Access Not accessible
Index cooScheduleNumberchassisIndex, cooScheduleNumberIndex

COO Schedule Number Chassis Index

Name cooScheduleNumberchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

COO Schedule Number Index

Name cooScheduleNumberIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.2
Description Defines the index of the schedule number information.
Syntax DellObjectRange
Access Read-only

Cost of Ownership Group 457


book.book Page 458 Monday, March 14, 2011 3:01 PM

COO Schedule Number State

Name cooScheduleNumberState
Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.3
Description Defines the schedule number information state of this system.
Syntax DellStateSettings
Access Read-only

COO Schedule Number Lease Information Index Reference

Name cooScheduleNumberLeaseInformationIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.4
Description Defines the lease information index number to reference the
schedule number.
Syntax DellUnsigned32BitRange
Access Read-write

COO Schedule Number Description Name

Name cooScheduleNumberDescriptionName
Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.5
Description Describes the schedule number information.
Syntax DellCostofOwnershipString
Access Read-write

COO Options Table

Name cooOptionsTable
Object ID 1.3.6.1.4.1.674.10892.1.1600.70
Description Defines the COO Options Table.
Syntax SEQUENCE OF CooOptionsTableEntry
Access Not accessible

458 Cost of Ownership Group


book.book Page 459 Monday, March 14, 2011 3:01 PM

COO Options Table Entry

Name cooOptionsTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1
Description Defines the COO Options Table entry.
Syntax CooOptionsTableEntry
Access Not accessible
Index cooOptionschassisIndex, cooOptionsIndex

COO Options Chassis Index

Name cooOptionschassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

COO Options Index

Name cooOptionsIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.2
Description Defines the index (one-based) of the option information for this
system.
Syntax DellObjectRange
Access Read-only

COO Options State

Name cooOptionsState
Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.3
Description Defines the option information state for this system.
Syntax DellStateSettings
Access Read-only

Cost of Ownership Group 459


book.book Page 460 Monday, March 14, 2011 3:01 PM

COO Options Lease Information Index Reference

Name cooOptionsLeaseInformationIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.4
Description Defines the lease information index of the option information for
this system.
Syntax DellUnsigned32BitRange
Access Read-write

COO Options Description Name

Name cooOptionsDescriptionName
Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.5
Description Defines the option information description name.
Syntax DellCostofOwnershipString
Access Read-write

COO Maintenance Table

Name cooMaintenanceTable
Object ID 1.3.6.1.4.1.674.10892.1.1600.80
Description Defines the COO Maintenance Table.
Syntax SEQUENCE OF CooMaintenanceTableEntry
Access Not accessible

COO Maintenance Table Entry

Name cooMaintenanceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1
Description Defines the COO Maintenance Table entry.
Syntax CooMaintenanceTableEntry
Access Not accessible
Index cooMaintenancechassisIndex, cooMaintenanceIndex

460 Cost of Ownership Group


book.book Page 461 Monday, March 14, 2011 3:01 PM

COO Maintenance Chassis Index

Name cooMaintenancechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

COO Maintenance Index

Name cooMaintenanceIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.2
Description Defines the index of this system’s maintenance information.
Syntax DellObjectRange
Access Read-only

COO Maintenance State

Name cooMaintenanceState
Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.3
Description Defines the state of this system’s maintenance information.
Syntax DellStateSettings
Access Read-only

COO Maintenance Start Date Name

Name cooMaintenanceStartDateName
Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.4
Description Defines the start date for maintenance on this system.
Syntax DellDateName
Access Read-write

Cost of Ownership Group 461


book.book Page 462 Monday, March 14, 2011 3:01 PM

COO Maintenance End Date Name

Name cooMaintenanceEndDateName
Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.5
Description Defines the end date for maintenance on this system.
Syntax DellDateName
Access Read-write

COO Maintenance Provider Name

Name cooMaintenanceProviderName
Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.6
Description Defines the maintenance provider’s name.
Syntax DellStateSettings
Access Read-write

COO Maintenance Restrictions Name

Name cooMaintenanceRestrictionsName
Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.7
Description Defines the maintenance agreement restrictions.
Syntax DellCostofOwnershipString
Access Read-write

COO Repair Table

Name cooRepairTable
Object ID 1.3.6.1.4.1.674.10892.1.1600.90
Description Defines the COO Repair Table.
Syntax SEQUENCE OF CooRepairTableEntry
Access Not accessible

462 Cost of Ownership Group


book.book Page 463 Monday, March 14, 2011 3:01 PM

COO Repair Table Entry

Name cooRepairTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1
Description Defines the COO Repair Table entry.
Syntax CooRepairTableEntry
Access Not accessible
Index cooRepairchassisIndex, cooRepairIndex

COO Repair Chassis Index

Name cooRepairchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

COO Repair Index

Name cooRepairIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.2
Description Defines the index (one-based) of the repair information for this
system.
Syntax DellObjectRange
Access Read-only

COO Repair State

Name cooRepairState
Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.3
Description Defines the state of the repair information for this system.
Syntax DellStateSettings
Access Read-only

Cost of Ownership Group 463


book.book Page 464 Monday, March 14, 2011 3:01 PM

COO Repair Counter

Name cooRepairCounter
Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.4
Description Defines the number of repairs that this system has undergone.
Syntax DellCostofOwnershipString
Access Read-write

COO Repair Vendor Name

Name cooRepairVendorName
Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.5
Description Defines the name of the vendor that repairs this system.
Syntax DellStateSettings
Access Read-only

COO Support Information Table

Name cooSupportInformationTable
Object ID 1.3.6.1.4.1.674.10892.1.1600.100
Description Defines the COO Support Information Table.
Syntax SEQUENCE OF cooSupportInformationTableEntry
Access Not accessible

COO Support Information Table Entry

Name cooSupportInformationTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1
Description Defines the COO Support Information Table entry.
Syntax cooSupportInformationTableEntry
Access Not accessible
Index cooSupportInformationchassisIndex
cooSupportInformationIndex

464 Cost of Ownership Group


book.book Page 465 Monday, March 14, 2011 3:01 PM

COO Support Information Chassis Index

Name cooSupportInformationchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

COO Support Information Index

Name cooSupportInformationIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.2
Description Defines the index (one-based) for this system’s support
information.
Syntax DellObjectRange
Access Read-only

COO Support Information State

Name cooSupportInformationState
Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.3
Description Defines the support information state for this system.
Syntax DellStateSettings
Access Read-only

COO Support Information Is Outsourced

Name cooSupportInformationIsOutsourced
Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.4
Description Specifies whether the support for this system is outsourced or not.
Syntax DellBoolean
Access Read-write

Cost of Ownership Group 465


book.book Page 466 Monday, March 14, 2011 3:01 PM

COO Support Information Type

Name cooSupportInformationType
Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.5
Description Defines the type of component, system, or network problem that
occurred.
Syntax DellUnsigned32BitRange
Access Read-write

COO Support Information Help Desk Name

Name cooSupportInformationHelpDeskName
Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.6
Description Defines the help desk information provided.
Syntax DellCostofOwnershipString
Access Read-write

COO Support Information Fix Type Name

Name cooSupportInformationFixTypeName
Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.7
Description Defines the method used to fix the problem.
Syntax DellCostofOwnershipString
Access Read-write

COO Trouble Ticket Table


The MIB objects in the Trouble Ticket Table enable you to track details of
any trouble tickets that you open for your system.

Name cooTroubleTicketTable
Object ID 1.3.6.1.4.1.674.10892.1.1600.110
Description Defines the COO Trouble Ticket Table.
Syntax SEQUENCE OF cooTroubleTicketTableEntry
Access Not accessible

466 Cost of Ownership Group


book.book Page 467 Monday, March 14, 2011 3:01 PM

COO Trouble Ticket Table Entry

Name cooTroubleTicketTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1
Description Defines the COO Trouble Ticket Table entry.
Syntax cooTroubleTicketTableEntry
Access Not accessible
Index cooTroubleTicketchassisIndex, cooTroubleTicketIndex

COO Trouble Ticket Chassis Index

Name cooTroubleTicketchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

COO Trouble Ticket Index

Name cooTroubleTicketIndex
Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.2
Description Defines the index (one-based) of the system’s trouble ticket
information.
Syntax DellObjectRange
Access Read-only

COO Trouble Ticket State

Name cooTroubleTicketState
Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.3
Description Defines the trouble ticket information state for this system.
Syntax DellStateSettings
Access Read-only

Cost of Ownership Group 467


book.book Page 468 Monday, March 14, 2011 3:01 PM

COO Trouble Ticket Support Information Index Reference

Name cooTroubleTicketSupportInformationIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.4
Description Defines the support information index that references the trouble ticket.
Syntax DellUnsigned32BitRange
Access Read-write

COO Trouble Ticket Number Name

Name cooTroubleTicketNumberName
Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.5
Description Defines the trouble ticket number for this system.
Syntax DellCostofOwnershipString
Access Read-write

Cost of Ownership Variable Values


This section includes definitions for server administrator-specific variable
values used in this section.

Table 19-1. COO Ownership Codes

Variable Name: DellCooOwnershipCodes


Data Type: Integer
Possible Data Values Meaning of Data Value
other(1) The ownership code is not one of following:
unknown(2) The ownership code is unknown.
owned(3) The ownership code is owned.
leased(4) The ownership code is leased.
rented(5) The ownership code is rented.
offOfLease(6) The ownership code is off of lease.
transfer(7) The ownership code is transfer.

468 Cost of Ownership Group


book.book Page 469 Monday, March 14, 2011 3:01 PM

Table 19-2. COO Hour Day Duration Type

Variable Name: DellCooHourDayDurationType


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Duration time type is unknown.
hours(2) Duration time type is in hours.
days(3) Duration time type is in days.

Table 19-3. COO Day Month Duration Type

Variable Name: DellCooDayMonthDurationType


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Duration time type is unknown.
days(3) Duration time type is in days.
months(4) Duration time type is in months.

Table 19-4. COO Month Year Duration Type

Variable Name: DellCooMonthYearDurationType


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) Duration time type is unknown.
months(4) Duration time type is in months.
years(5) Duration time type is in years.

Cost of Ownership Group 469


book.book Page 470 Monday, March 14, 2011 3:01 PM

470 Cost of Ownership Group


book.book Page 471 Monday, March 14, 2011 3:01 PM

20
Remote Access Group
The Remote Access Group provides information about the remote access
hardware that may be present in your system. In addition to providing general
information about the capabilities and settings of the remote access
hardware, this group provides information about administrative users,
SNMP trap destinations, modem configuration for dial-up networking,
dial-in configuration, and dial-out destinations.

DRAC 4 and DRAC 5


On systems with Dell Remote Access Controller (DRAC) 4 or DRAC 5,
the Remote Access Group includes only the Remote Access Table.

Remote Access Table


The following MIB object sets up the Remote Access Table.

Name remoteAccessTable
Object ID 1.3.6.1.4.1.674.10892.1.1700.10
Description Defines the Remote Access Table.
Syntax SEQUENCE OF RemoteAccessTableEntry
Access Not accessible

Remote Access Table Entry

Name remoteAccessTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1
Description Defines the Remote Access Table entry.
Syntax RemoteAccessTableEntry
Access Not accessible
Index remoteAccessChassisIndex, remoteAccessAdapterIndex

Remote Access Group 471


book.book Page 472 Monday, March 14, 2011 3:01 PM

Remote Access Chassis Index

Name remoteAccessChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.1
Description Defines the index (one-based) of the chassis containing the
remote access hardware.
Syntax DellObjectRange
Access Read-only

Remote Access Adapter Index

Name remoteAccessAdapterIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.2
Description Defines the index (one-based) of the remote access hardware.
Syntax DellObjectRange
Access Read-only

Remote Access Type

Name remoteAccessType
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.3
Description Defines the type of remote access hardware.
Syntax DellRemoteAccessType (See Table 20-1)
Access Read-only

Remote Access State Capabilities

Name remoteAccessStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.4
Description Defines the state capabilities of the remote access hardware.
Syntax DellStateCapabilities
Access Read-only

472 Remote Access Group


book.book Page 473 Monday, March 14, 2011 3:01 PM

Remote Access State Settings

Name remoteAccessStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.5
Description Defines the state setting of the remote access hardware.
Syntax DellStateSettings
Access Read-write

Remote Access Status

Name remoteAccessStatus
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.6
Description Defines the status of the remote access hardware.
Syntax DellStatus
Access Read-only

Remote Access Product Info Name

Name remoteAccessProductInfoName
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.7
Description Defines the name of the product providing the remote access
functionality.
Syntax DellDisplayString (SIZE (0..63))
Access Read-only

Remote Access Description Info Name

Name remoteAccessDescriptionInfoName
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.8
Description Defines the description of the product providing the remote
access functionality.
Syntax DellDisplayString (SIZE (0..255))
Access Read-only

Remote Access Group 473


book.book Page 474 Monday, March 14, 2011 3:01 PM

Remote Access Version Info Name

Name remoteAccessVersionInfoName
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.9
Description Defines the version of the product providing the remote access
functionality.
Syntax DellDisplayString (SIZE (0..63))
Access Read-only

Remote Access Local Area Network (LAN) Capabilities

Name remoteAccessLANCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.14
Description Defines the LAN capabilities of the remote access hardware.
Syntax DellRemoteAccessLANCapabilities (See Table 20-6)
Access Read-only

Remote Access LAN Settings

Name remoteAccessLANSettings
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.15
Description Defines the LAN settings of the remote access hardware.
Syntax DellRemoteAccessLANSettings (See Table 20-7)
Access Read-write

Remote Access Network Interface Controller (NIC) Static IP Address

Name remoteAccessNICStaticIPAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.25
Description Defines the static IP address to be used by the integrated NIC
provided by the remote access hardware.
Syntax IpAddress
Access Read-write

474 Remote Access Group


book.book Page 475 Monday, March 14, 2011 3:01 PM

Remote Access NIC Static Netmask Address

Name remoteAccessNICStaticNetmaskAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.26
Description Defines the netmask for the static IP address to be used by the
integrated NIC provided by the remote access hardware.
Syntax IpAddress
Access Read-write

Remote Access NIC Static Gateway Address

Name remoteAccessNICStaticGatewayAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.27
Description Defines the IP address for the gateway associated with the static
IP address to be used by the integrated NIC provided by the
remote access hardware.
Syntax IpAddress
Access Read-write

Remote Access Personal Computer Memory Card International Association


(PCMCIA) Info Name

Name remoteAccessPCMCIAInfoName
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.28
Description Defines the information for the PCMCIA device used by the
remote access hardware.
Syntax DisplayString (SIZE (0..63))
Access Read-only

Remote Access Group 475


book.book Page 476 Monday, March 14, 2011 3:01 PM

Remote Access Miscellaneous Information Name

Name remoteAccessMiscInfoName
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.29
Description Defines the miscellaneous information for the remote access hardware.
Syntax DisplayString (SIZE (0..63))
Access Read-write

Remote Access NIC Current IP Address

Name remoteAccessNICCurrentIPAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.30
Description Defines the IP address currently being used by the integrated
NIC provided by the remote access hardware.
Syntax IpAddress
Access Read-only

Remote Access NIC Current Netmask Address

Name remoteAccessNICCurrentNetmaskAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.31
Description Defines the netmask currently being used by the integrated NIC
provided by the remote access hardware.
Syntax IpAddress
Access Read-only

Remote Access NIC Current Gateway Address

Name remoteAccessNICCurrentGatewayAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.32
Description Defines the IP address for the gateway currently being used by
the integrated NIC provided by the remote access hardware.
Syntax IpAddress
Access Read-only

476 Remote Access Group


book.book Page 477 Monday, March 14, 2011 3:01 PM

Remote Access NIC Current Information From Dynamic Host Configuration Protocol
(DHCP)

Name remoteAccessNICCurrentInfoFromDHCP
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.33
Description Defines whether DHCP was used to obtain the NIC
information currently being used by the integrated NIC
provided by the remote access hardware.
Syntax DellBoolean
Access Read-only

Remote Access Remote Connect URL

Name remoteAccessRemoteConnectURL
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.34
Description Defines the URL for launching the Remote Access Remote
Connect Interface.
Syntax DisplayString (SIZE (0..63))
Access Mandatory

DRAC III
On systems with DRAC III, the Remote Access Group includes the following
MIB tables:
• "Remote Access Table" on page 478
• "Remote User Administration Table" on page 487
• "Remote SNMP Trap Table" on page 495
• "Remote Dial-Up Table" on page 500
• "Remote User Dial-In Configuration Table" on page 504
• "Remote Dial-Out Table" on page 507

Remote Access Group 477


book.book Page 478 Monday, March 14, 2011 3:01 PM

Remote Access Table


The following MIB object sets up the Remote Access Table.

Name remoteAccessTable
Object ID 1.3.6.1.4.1.674.10892.1.1700.10
Description Defines the Remote Access Table.
Syntax SEQUENCE OF RemoteAccessTableEntry
Access Not accessible

Remote Access Table Entry

Name remoteAccessTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1
Description Defines the Remote Access Table entry.
Syntax RemoteAccessTableEntry
Access Not accessible
Index remoteAccessChassisIndex, remoteAccessAdapterIndex

Remote Access Chassis Index

Name remoteAccessChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.1
Description Defines the index (one-based) of the chassis containing the
remote access hardware.
Syntax DellObjectRange
Access Read-only

Remote Access Adapter Index

Name remoteAccessAdapterIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.2
Description Defines the index (one-based) of the remote access hardware.
Syntax DellObjectRange
Access Read-only

478 Remote Access Group


book.book Page 479 Monday, March 14, 2011 3:01 PM

Remote Access Type

Name remoteAccessType
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.3
Description Defines the type of remote access hardware.
Syntax DellRemoteAccessType (See Table 20-1)
Access Read-only

Remote Access State Capabilities

Name remoteAccessStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.4
Description Defines the state capabilities of the remote access hardware.
Syntax DellStateCapabilities
Access Read-only

Remote Access State Settings

Name remoteAccessStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.5
Description Defines the state setting of the remote access hardware.
Syntax DellStateSettings
Access Read-write

Remote Access Status

Name remoteAccessStatus
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.6
Description Defines the status of the remote access hardware.
Syntax DellStatus
Access Read-only

Remote Access Group 479


book.book Page 480 Monday, March 14, 2011 3:01 PM

Remote Access Product Info Name

Name remoteAccessProductInfoName
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.7
Description Defines the name of the product providing the remote access
functionality.
Syntax DellDisplayString (SIZE (0..63))
Access Read-only

Remote Access Description Info Name

Name remoteAccessDescriptionInfoName
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.8
Description Defines the description of the product providing the remote access
functionality.
Syntax DellDisplayString (SIZE (0..255))
Access Read-only

Remote Access Version Info Name

Name remoteAccessVersionInfoName
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.9
Description Defines the version of the product providing the remote access
functionality.
Syntax DellDisplayString (SIZE (0..63))
Access Read-only

Remote Access Control Capabilities

Name remoteAccessControlCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.10
Description Defines the control capabilities of the remote access hardware.
Syntax DellRemoteAccessControlCapabilities (See Table 20-2)
Access Read-only

480 Remote Access Group


book.book Page 481 Monday, March 14, 2011 3:01 PM

Remote Access Control Settings

Name remoteAccessControlSettings
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.11
Description Defines the control settings of the remote access hardware.
Syntax DellRemoteAccessControlSettings (See Table 20-3)
Access Read-write

Remote Access Monitor Capabilities

Name remoteAccessMonitorCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.12
Description Defines the monitor capabilities of the remote access hardware.
Syntax DellRemoteAccessMonitorCapabilities (See Table 20-4)
Access Read-only

Remote Access Monitor Settings

Name remoteAccessMonitorSettings
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.13
Description Defines the monitor settings of the remote access hardware.
Syntax DellRemoteAccessMonitorSettings (See Table 20-5)
Access Read-write

Remote Access Local Area Network (LAN) Capabilities

Name remoteAccessLANCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.14
Description Defines the LAN capabilities of the remote access hardware.
Syntax DellRemoteAccessLANCapabilities (See Table 20-6)
Access Read-only

Remote Access Group 481


book.book Page 482 Monday, March 14, 2011 3:01 PM

Remote Access LAN Settings

Name remoteAccessLANSettings
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.15
Description Defines the LAN settings of the remote access hardware.
Syntax DellRemoteAccessLANSettings (See Table 20-7)
Access Read-write

Remote Access Host Capabilities

Name remoteAccessHostCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.16
Description Defines the host capabilities of the remote access hardware.
Syntax DellRemoteAccessHostCapabilities (See Table 20-8)
Access Read-only

Remote Access Host Settings

Name remoteAccessHostSettings
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.17
Description Defines the host settings of the remote access hardware.
Syntax DellRemoteAccessHostSettings (See Table 20-9)
Access Read-write

Remote Access Out-of-Band Simple Network Management Protocol (SNMP)


Capabilities

Name remoteAccessOutOfBandSNMPCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.18
Description Defines the out-of-band SNMP capabilities of the remote access
hardware.
Syntax DellRemoteAccessOutOfBandSNMPCapabilities (See
Table 20-10)
Access Read-only

482 Remote Access Group


book.book Page 483 Monday, March 14, 2011 3:01 PM

Remote Access Out-of-Band SNMP Settings

Name remoteAccessOutOfBandSNMPSettings
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.19
Description Defines the out-of-band SNMP settings of the remote access hardware.
Syntax DellRemoteAccessOutOfBandSNMPSettings (See Table 20-11)
Access Read-write

Remote Access Simple Mail Transfer Protocol (SMTP) Server Internet Protocol (IP)
Address

Name remoteAccessSMTPServerIPAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.20
Description Defines the IP address for the SMTP server used by the remote
access hardware.
Syntax IpAddress
Access Read-write

Remote Access Floppy Trivial File Transfer Protocol (TFTP) IP Address

Name remoteAccessFloppyTFTPIPAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.21
Description Defines the IP address of the TFTP server providing the
operating system image used by the remote access hardware.
Syntax IpAddress
Access Read-write

Remote Access Floppy TFTP Path Name

Name remoteAccessFloppyTFTPPathName
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.22
Description Defines the file name of the operating system image obtained
from the TFTP server used by the remote access hardware.
Syntax DisplayString (SIZE (0..255))
Access Read-write

Remote Access Group 483


book.book Page 484 Monday, March 14, 2011 3:01 PM

Remote Access Firmware Update IP Address

Name remoteAccessFirmwareUpdateIPAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.23
Description Defines the IP address of the update server providing the
firmware image used by the remote access hardware.
Syntax IpAddress
Access Read-write

Remote Access Firmware Update Path Name

Name remoteAccessFirmwareUpdatePathName
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.24
Description Defines the file name of the firmware image obtained from the
update server used by the remote access hardware.
Syntax DisplayString (SIZE (0..255))
Access Read-write

Remote Access Network Interface Controller (NIC) Static IP Address

Name remoteAccessNICStaticIPAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.25
Description Defines the static IP address to be used by the integrated NIC
provided by the remote access hardware.
Syntax IpAddress
Access Read-write

Remote Access NIC Static Netmask Address

Name remoteAccessNICStaticNetmaskAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.26
Description Defines the netmask for the static IP address to be used by the
integrated NIC provided by the remote access hardware.
Syntax IpAddress
Access Read-write

484 Remote Access Group


book.book Page 485 Monday, March 14, 2011 3:01 PM

Remote Access NIC Static Gateway Address

Name remoteAccessNICStaticGatewayAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.27
Description Defines the IP address for the gateway associated with the static
IP address to be used by the integrated NIC provided by the
remote access hardware.
Syntax IpAddress
Access Read-write

Remote Access Personal Computer Memory Card International Association (PCMCIA)


Info Name

Name remoteAccessPCMCIAInfoName
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.28
Description Defines the information for the PCMCIA device used by the
remote access hardware.
Syntax DisplayString (SIZE (0..63))
Access Read-only

Remote Access Miscellaneous Information Name

Name remoteAccessMiscInfoName
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.29
Description Defines the miscellaneous information for the remote
access hardware.
Syntax DisplayString (SIZE (0..63))
Access Read-write

Remote Access Group 485


book.book Page 486 Monday, March 14, 2011 3:01 PM

Remote Access NIC Current IP Address

Name remoteAccessNICCurrentIPAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.30
Description Defines the IP address currently being used by the integrated
NIC provided by the remote access hardware.
Syntax IpAddress
Access Read-only

Remote Access NIC Current Netmask Address

Name remoteAccessNICCurrentNetmaskAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.31
Description Defines the netmask currently being used by the integrated NIC
provided by the remote access hardware.
Syntax IpAddress
Access Read-only

Remote Access NIC Current Gateway Address

Name remoteAccessNICCurrentGatewayAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.32
Description Defines the IP address for the gateway currently being used by
the integrated NIC provided by the remote access hardware.
Syntax IpAddress
Access Read-only

486 Remote Access Group


book.book Page 487 Monday, March 14, 2011 3:01 PM

Remote Access NIC Current Information From Dynamic Host Configuration Protocol
(DHCP)

Name remoteAccessNICCurrentInfoFromDHCP
Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.33
Description Defines whether DHCP was used to obtain the NIC
information currently being used by the integrated NIC
provided by the remote access hardware.
Syntax DellBoolean
Access Read-only

Remote User Administration Table

Name remoteUserAdminTable
Object ID 1.3.6.1.4.1.674.10892.1.1700.20
Description Defines the Remote Access User Administration Table.
Syntax SEQUENCE OF RemoteUserAdminTableEntry
Access Not accessible

Remote User Admin Table Entry

Name remoteUserAdminTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1
Description Defines the Remote Access User Administration Table entry.
Syntax RemoteUserAdminTableEntry
Access Not accessible
Index remoteUserAdminChassisIndex,
remoteUserAdminAdapterIndex, remoteUserAdminUserIndex

Remote Access Group 487


book.book Page 488 Monday, March 14, 2011 3:01 PM

Remote User Admin Chassis Index

Name remoteUserAdminChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.1
Description Defines the index (one-based) of the chassis containing the
remote access hardware.
Syntax DellObjectRange
Access Read-only

Remote User Admin Adapter Index

Name remoteUserAdminAdapterIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.2
Description Defines the index (one-based) of the remote access hardware
used by this remote access user.
Syntax DellObjectRange
Access Read-only

Remote User Admin User Index

Name remoteUserAdminUserIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.3
Description Defines the index (one-based) of this remote access user.
Syntax DellObjectRange
Access Read-only

Remote User Admin State Capabilities

Name remoteUserAdminStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.4
Description Defines the state capabilities for this remote access user.
Syntax DellRemoteUserAdminStateCapabilities (See Table 20-12)
Access Read-only

488 Remote Access Group


book.book Page 489 Monday, March 14, 2011 3:01 PM

Remote User Admin State Settings

Name remoteUserAdminStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.5
Description Defines the state settings for this remote access user.
Syntax DellRemoteUserAdminStateSettings (See Table 20-13)
Access Read-write

Remote User Admin Status

Name remoteUserAdminStatus
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.6
Description Defines the status for this remote access user.
Syntax DellStatus
Access Read-only

Remote User Admin User Name

Name remoteUserAdminUserName
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.7
Description Defines the user name for this remote access user.
Syntax DisplayString (SIZE (0..19))
Access Read-write

Remote User Admin User Password Name

Name remoteUserAdminUserPasswordName
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.8
Description Defines the password for this remote access user.
Syntax DisplayString (SIZE (0..255))
Access Read-write

Remote Access Group 489


book.book Page 490 Monday, March 14, 2011 3:01 PM

Remote User Admin User Privilege

Name remoteUserAdminUserPrivilege
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.9
Description Defines the privileges for this remote access user.
Syntax DisplayString (SIZE (0..31))
Access Read-write

Remote User Admin User Privilege Capabilities

Name remoteUserAdminUserPrivilegeCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.10
Description Defines the privilege capabilities for this remote access user.
Syntax DisplayString (SIZE (0..31))
Access Read-only

Remote User Admin Alert Filter DRS Events Mask

Name remoteUserAdminAlertFilterDrsEventsMask
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.11
Description Defines the DRS events filter mask for this remote access user.
Syntax DellUnsigned32BitRange
Access Read-write

Remote User Admin Alert Filter System Events Mask

Name remoteUserAdminAlertFilterSysEventsMask
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.12
Description Defines the system events filter mask for this remote access user.
Syntax DellUnsigned32BitRange
Access Read-write

490 Remote Access Group


book.book Page 491 Monday, March 14, 2011 3:01 PM

Remote User Admin Alert Filter DRS Capabilities

Name remoteUserAdminAlertFilterDrsCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.13
Description Defines the DRS events filter capabilities for this remote access user.
Syntax DellUnsigned32BitRange
Access Read-only

Remote User Admin Alert Filter System Capabilities

Name remoteUserAdminAlertFilterSysCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.14
Description Defines the system events filter capabilities for this remote
access user.
Syntax DellUnsigned32BitRange
Access Read-only

Remote User Admin Pager Numeric Number Name

Name remoteUserAdminPagerNumericNumberName
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.15
Description Defines the numeric pager number for this remote access user.
Syntax DisplayString (SIZE (0..95))
Access Read-write

Remote User Admin Pager Numeric Message Name

Name remoteUserAdminPagerNumericMessageName
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.16
Description Defines the message to send to the numeric pager for this remote
access user.
Syntax DisplayString (SIZE (0..31))
Access Read-write

Remote Access Group 491


book.book Page 492 Monday, March 14, 2011 3:01 PM

Remote User Admin Pager Numeric Hang-up Delay

Name remoteUserAdminPagerNumericHangupDelay
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.17
Description Defines the numeric pager hang-up delay for this remote access user.
Syntax DellUnsigned32BitRange
Access Read-write

Remote User Admin Pager Alpha Phone Number Name

Name remoteUserAdminPagerAlphaPhoneNumberName
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.18
Description Defines the alphanumeric pager phone number for this remote
access user.
Syntax DisplayString (SIZE (0..95))
Access Read-write

Remote User Admin Pager Alpha Protocol

Name remoteUserAdminPagerAlphaProtocol
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.19
Description Defines the protocol used by the alphanumeric pager provider
for this remote access user.
Syntax DellRemoteUserAdminAlphaProtocolType (See Table 20-16)
Access Read-write

Remote User Admin Pager Alpha Baud Rate

Name remoteUserAdminPagerAlphaBaudRate
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.20
Description Defines the baud rate used by the alphanumeric pager provider
for this remote access user.
Syntax DellRemoteUserAdminAlphaBaudType (See Table 20-17)
Access Read-write

492 Remote Access Group


book.book Page 493 Monday, March 14, 2011 3:01 PM

Remote User Admin Pager Alpha Custom Message Name

Name remoteUserAdminPagerAlphaCustomMessageName
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.21
Description Defines the message to be sent to the alphanumeric pager to
inform the user of a call by this remote access user.
Syntax DisplayString (SIZE (0..31))
Access Read-write

Remote User Admin Pager Alpha Modem Connect Time-out

Name remoteUserAdminPagerAlphaModemConnectTimeout
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.22
Description Defines the modem connection time-out for the alphanumeric
pager for this remote access user.
Syntax DellUnsigned32BitRange
Access Read-write

Remote User Admin Pager Alpha Pager ID Name

Name remoteUserAdminPagerAlphaPagerIdName
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.23
Description Defines the ID to be sent to the alphanumeric pager to inform
the user of a call by this remote access user.
Syntax DisplayString (SIZE (0..31))
Access Read-write

Remote User Admin Pager Alpha Password Name

Name remoteUserAdminPagerAlphaPasswordName
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.24
Description Defines the password for the alphanumeric pager for this remote
access user.
Syntax DisplayString (SIZE (0..31))
Access Read-write

Remote Access Group 493


book.book Page 494 Monday, March 14, 2011 3:01 PM

Remote User Admin Pager Modem Init String Name

Name remoteUserAdminPagerModemInitStringName
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.25
Description Defines the initialization string to be sent to the pager modem
for this remote access user.
Syntax DisplayString (SIZE (0..31))
Access Read-write

Remote User Admin Pager Modem Port

Name remoteUserAdminPagerModemPort
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.26
Description Defines the port for the pager modem for this remote access
user.
Syntax DellUnsigned32BitRange
Access Read-write

Remote User Admin E-Mail Address Name

Name remoteUserAdminEmailAddressName
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.27
Description Defines the e-mail address for this remote access user.
Syntax DisplayString (SIZE (0..63))
Access Read-write

Remote User Admin E-Mail Custom Message Name

Name remoteUserAdminEmailCustomMessageName
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.28
Description Defines the e-mail message to send to this remote access user.
Syntax DisplayString (SIZE (0..31))
Access Read-write

494 Remote Access Group


book.book Page 495 Monday, March 14, 2011 3:01 PM

Remote User Admin Control Capabilities

Name remoteUserAdminControlCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.29
Description Defines the control capabilities for this remote access user.
Syntax DellRemoteUserAdminControlCapabilities (See Table 20-14 on
page 517)
Access Read-only

Remote User Admin Control Settings

Name remoteUserAdminControlSettings
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.30
Description Defines the control settings for this remote access user.
Syntax DellRemoteUserAdminControlSettings (See Table 20-15)
Access Read-write

Remote User Admin User Type

Name remoteUserAdminUserType
Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.31
Description Defines the type of user for this remote access user.
Syntax DellUnsigned8BitRange
Access Read-write

Remote SNMP Trap Table

Name remoteSNMPTrapTable
Object ID 1.3.6.1.4.1.674.10892.1.1700.30
Description Defines the Remote Access SNMP Trap Destination Table.
Syntax SEQUENCE OF RemoteSNMPTrapTableEntry
Access Not accessible

Remote Access Group 495


book.book Page 496 Monday, March 14, 2011 3:01 PM

Remote SNMP Trap Table Entry

Name remoteSNMPTrapTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1
Description Defines the Remote Access SNMP Trap Destination Table entry.
Syntax RemoteSNMPTrapTableEntry
Access Not accessible
Index remoteSNMPTrapChassisIndex,
remoteSNMPTrapAdapterIndex, remoteSNMPTrapIndex

Remote SNMP Trap Chassis Index

Name remoteSNMPTrapChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.1
Description Defines the index (one-based) of the chassis containing the
remote access hardware.
Syntax DellObjectRange
Access Read-only

Remote SNMP Trap Adapter Index

Name remoteSNMPTrapAdapterIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.2
Description Defines the index (one-based) of the remote access hardware
that uses this SNMP trap destination.
Syntax DellObjectRange
Access Read-only

496 Remote Access Group


book.book Page 497 Monday, March 14, 2011 3:01 PM

Remote SNMP Trap Index

Name remoteSNMPTrapIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.3
Description Defines the index (one-based) of this remote access SNMP trap
destination.
Syntax DellObjectRange
Access Read-only

Remote SNMP Trap State Capabilities

Name remoteSNMPTrapStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.4
Description Defines the state capabilities of this remote access SNMP trap
destination.
Syntax DellRemoteSNMPTrapStateCapabilities (See Table 20-18)
Access Read-only

Remote SNMP Trap State Settings

Name remoteSNMPTrapStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.5
Description Defines the state settings of this remote access SNMP trap
destination.
Syntax DellRemoteSNMPTrapStateSettings (See Table 20-19)
Access Read-write

Remote SNMP Trap Status

Name remoteSNMPTrapStatus
Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.6
Description Defines the status of this remote access SNMP trap destination.
Syntax DellStatus
Access Read-only

Remote Access Group 497


book.book Page 498 Monday, March 14, 2011 3:01 PM

Remote SNMP Trap Destination IP Address

Name remoteSNMPTrapDestinationIPAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.7
Description Defines the IP address of this remote access SNMP trap destination.
Syntax IpAddress
Access Read-write

Remote SNMP Trap SNMP Community Name

Name remoteSNMPTrapSNMPCommunityName
Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.8
Description Defines the community for traps sent to this remote access
SNMP trap destination.
Syntax DisplayString (SIZE (0..31))
Access Read-write

Remote SNMP Trap Filter DRS Events Mask

Name remoteSNMPTrapFilterDrsEventsMask
Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.9
Description Defines the DRS events filter mask for this remote access
SNMP trap destination.
Syntax DellUnsigned32BitRange
Access Read-write

Remote SNMP Trap Filter System Events Mask

Name remoteSNMPTrapFilterSysEventsMask
Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.10
Description Defines the system events filter mask for this remote access
SNMP trap destination.
Syntax DellUnsigned32BitRange
Access Read-write

498 Remote Access Group


book.book Page 499 Monday, March 14, 2011 3:01 PM

Remote SNMP Trap Filter DRS Capabilities

Name remoteSNMPTrapFilterDrsCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.11
Description Defines the DRS events filter capabilities for this remote access
SNMP trap destination.
Syntax DellUnsigned32BitRange
Access Read-only

Remote SNMP Trap Filter System Capabilities

Name remoteSNMPTrapFilterSysCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.12
Description Defines the system events filter capabilities of this remote
access SNMP trap destination.
Syntax DellUnsigned32BitRange
Access Read-only

Remote SNMP Trap Control Capabilities

Name remoteSNMPTrapControlCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.13
Description Defines the control capabilities of this remote access
SNMP trap destination.
Syntax DellRemoteSNMPTrapControlCapabilities (See Table 20-20)
Access Read-only

Remote SNMP Trap Control Settings

Name remoteSNMPTrapControlSettings
Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.14
Description Defines the control settings of this remote access SNMP
trap destination.
Syntax DellRemoteSNMPTrapControlSettings (See Table 20-21)
Access Read-write

Remote Access Group 499


book.book Page 500 Monday, March 14, 2011 3:01 PM

Remote Dial-Up Table

Name remoteDialUpTable
Object ID 1.3.6.1.4.1.674.10892.1.1700.40
Description Defines the Remote Access Dial-Up Table.
Syntax SEQUENCE OF RemoteDialUpTableEntry
Access Not accessible

Remote Dial-Up Table Entry

Name remoteDialUpTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1
Description Defines the Remote Access Dial-Up Table entry.
Syntax RemoteDialUpTableEntry
Access Not accessible
Index remoteDialUpChassisIndex, remoteDialUpAdapterIndex,
remoteDialUpIndex

Remote Dial-Up Chassis Index

Name remoteDialUpChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.1
Description Defines the index (one-based) of the chassis containing the
remote access hardware.
Syntax DellObjectRange
Access Read-only

500 Remote Access Group


book.book Page 501 Monday, March 14, 2011 3:01 PM

Remote Dial-Up Adapter Index

Name remoteDialUpAdapterIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.2
Description Defines the index (one-based) of the remote access hardware
that supports this remote access dial-up functionality.
Syntax DellObjectRange
Access Read-only

Remote Dial-Up Index

Name remoteDialUpIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.3
Description Defines the index (one-based) of this remote access dial-up
functionality.
Syntax DellObjectRange
Access Read-only

Remote Dial-Up State Capabilities

Name remoteDialUpStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.4
Description Defines the state capabilities of this remote access dial-up
functionality.
Syntax DellRemoteDialUpStateCapabilities (See Table 20-22)
Access Read-only

Remote Dial-Up State Settings

Name remoteDialUpStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.5
Description Defines the state settings of this remote access dial-up
functionality.
Syntax DellRemoteDialUpStateSettings (See Table 20-23)
Access Read-write

Remote Access Group 501


book.book Page 502 Monday, March 14, 2011 3:01 PM

Remote Dial-Up Status

Name remoteDialUpStatus
Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.6
Description Defines the status of this remote access dial-up functionality.
Syntax DellStatus
Access Read-only

Remote Dial-Up PPP Dial-In Base IP Address

Name remoteDialUpPPPDialInBaseIPAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.7
Description Defines the base IP address of the PPP server for this remote
access dial-up functionality.
Syntax IpAddress
Access Read-write

Remote Dial-Up PPP Dial-In Idle Time-out

Name remoteDialUpPPPDialInIdleTimeout
Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.8
Description Defines the PPP idle time-out value in seconds for this remote
access dial-up functionality.
Syntax DellUnsigned32BitRange
Access Read-write

Remote Dial-Up PPP Dial-In Maximum Connection Time-out

Name remoteDialUpPPPDialInMaxConnectTimeout
Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.9
Description Defines the PPP connect time-out value in seconds for this
remote access dial-up functionality.
Syntax DellUnsigned32BitRange
Access Read-write

502 Remote Access Group


book.book Page 503 Monday, March 14, 2011 3:01 PM

Remote Dial-Up Dial-Out Modem Connect Time-out

Name remoteDialUpDialOutModemConnectTimeout
Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.10
Description Defines the modem dial-out time-out value in seconds for this
remote access dial-up functionality.
Syntax DellUnsigned32BitRange
Access Read-write

Remote Dial-Up Modem Dial Type

Name remoteDialUpModemDialType
Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.11
Description Defines the dial type for the modem used by this remote access
dial-up functionality.
Syntax DellRemoteDialUpModemDialType (See Table 20-24)
Access Read-write

Remote Dial-Up Modem Init String Name

Name remoteDialUpModemInitStringName
Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.12
Description Defines the initialization string to be sent to the modem for this
remote access dial-up functionality.
Syntax DisplayString (SIZE (0..63))
Access Read-write

Remote Dial-Up Modem Baud Rate

Name remoteDialUpModemBaudRate
Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.13
Description Defines the baud rate for the modem used by this remote access
dial-up functionality.
Syntax DellUnsigned32BitRange
Access Read-write

Remote Access Group 503


book.book Page 504 Monday, March 14, 2011 3:01 PM

Remote Dial-Up Modem Port

Name remoteDialUpModemPort
Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.14
Description Defines the port for the modem used by this remote access dial-
up functionality.
Syntax DellUnsigned32BitRange
Access Read-write

Remote User Dial-In Configuration Table

Name remoteUserDialInCfgTable
Object ID 1.3.6.1.4.1.674.10892.1.1700.50
Description Defines the Remote Access User Dial-In Configuration Table.
Syntax SEQUENCE OF RemoteUserDialInCfgTableEntry
Access Not accessible

Remote User Dial-In Configuration Table Entry

Name remoteUserDialInCfgTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1
Description Defines the Remote Access User Dial-In Configuration Table
entry.
Syntax RemoteUserDialInCfgTableEntry
Access Not accessible
Index remoteUserDialInCfgChassisIndex,
remoteUserDialInCfgAdapterIndex,
remoteUserDialInCfgUserIndex

504 Remote Access Group


book.book Page 505 Monday, March 14, 2011 3:01 PM

Remote User Dial-In Configuration Chassis Index

Name remoteUserDialInCfgChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.1
Description Defines the index (one-based) of the chassis containing the
remote access hardware.
Syntax DellObjectRange
Access Read-only

Remote User Dial-In Configuration Adapter Index

Name remoteUserDialInCfgAdapterIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.2
Description Defines the index (one-based) of the remote access hardware
that supports this remote access dial-in user.
Syntax DellObjectRange
Access Read-only

Remote User Dial-In Configuration User Index

Name remoteUserDialInCfgUserIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.3
Description Defines the index (one-based) of this remote access dial-in user.
Syntax DellObjectRange
Access Read-only

Remote User Dial-In Configuration State Capabilities

Name remoteUserDialInCfgStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.4
Description Defines the state capabilities of this remote access dial-in user.
Syntax DellRemoteUserDialInStateCapabilities (See Table 20-25)
Access Read-only

Remote Access Group 505


book.book Page 506 Monday, March 14, 2011 3:01 PM

Remote User Dial-In Configuration State Settings

Name remoteUserDialInCfgStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.5
Description Defines the state settings of this remote access dial-in user.
Syntax DellRemoteUserDialInStateSettings (See Table 20-26)
Access Read-write

Remote User Dial-In Configuration Status

Name remoteUserDialInCfgStatus
Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.6
Description Defines the status of this remote access dial-in user.
Syntax DellStatus
Access Read-only

Remote User Dial-In Configuration PPP Username

Name remoteUserDialInCfgPPPUserName
Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.7
Description Defines the PPP user name of this remote access dial-in user.
Syntax DisplayString (SIZE (0..15))
Access Read-write

Remote User Dial-In Configuration PPP User Password Name

Name remoteUserDialInCfgPPPUserPasswordName
Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.8
Description Defines the PPP password of this remote access dial-in user.
Syntax DisplayString (SIZE (0..15))
Access Read-write

506 Remote Access Group


book.book Page 507 Monday, March 14, 2011 3:01 PM

Remote User Dial-In Configuration Callback Phone Number Name

Name remoteUserDialInCfgCallbackPhoneNumberName
Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.9
Description Defines the callback phone number for this remote access dial-in user.
Syntax DisplayString (SIZE (0..95))
Access Read-write

Remote Dial-Out Table


Name remoteDialOutTable
Object ID 1.3.6.1.4.1.674.10892.1.1700.60
Description Defines the Remote Access Dial-Out Table.
Syntax SEQUENCE of RemoteDialOutTableEntry
Access Not accessible

Remote Dial-Out Table Entry

Name remoteDialOutTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1
Description Defines the Remote Access Dial-Out Table entry.
Syntax RemoteDialOutTableEntry
Access Not accessible
Index remoteDialOutChassisIndex, remoteDialOutAdapterIndex,
remoteDialOutDialOutIndex

Remote Dial-Out Chassis Index

Name remoteDialOutChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.1
Description Defines the index (one-based) of the chassis containing the
remote access hardware.
Syntax DellObjectRange
Access Read-only

Remote Access Group 507


book.book Page 508 Monday, March 14, 2011 3:01 PM

Remote Dial-Out Adapter Index

Name remoteDialOutAdapterIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.2
Description Defines the index (one-based) of the remote access hardware
that supports this remote access dial-out functionality.
Syntax DellObjectRange
Access Read-only

Remote Dial-Out Dial-Out Index

Name remoteDialOutDialOutIndex
Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.3
Description Defines the index (one-based) of this remote access dial-out
functionality.
Syntax DellObjectRange
Access Read-only

Remote Dial-Out State Capabilities

Name remoteDialOutStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.4
Description Defines the state capabilities of this remote access dial-out
functionality.
Syntax DellRemoteDialOutStateCapabilities (See Table 20-27)
Access Read-only

Remote Dial-Out State Settings

Name remoteDialOutStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.5
Description Defines the state settings of this remote access dial-out functionality.
Syntax DellRemoteDialOutStateSettings (See Table 20-28)
Access Read-write

508 Remote Access Group


book.book Page 509 Monday, March 14, 2011 3:01 PM

Remote Dial-Out Status

Name remoteDialOutStatus
Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.6
Description Defines the status of this remote access dial-out functionality.
Syntax DellStatus
Access Read-only

Remote Dial-Out IP Address

Name remoteDialOutIPAddress
Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.7
Description Defines the IP address for this remote access dial-out
destination.
Syntax IpAddress
Access Read-write

Remote Dial-Out Phone Number Name

Name remoteDialOutPhoneNumberName
Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.8
Description Defines the phone number for this remote access dial-out
destination.
Syntax DisplayString (SIZE (0..95))
Access Read-write

Remote Dial-Out PPP Username

Name remoteDialOutPPPUserName
Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.9
Description Defines the PPP username for this remote access dial-out
destination.
Syntax DisplayString (SIZE (0..31))
Access Read-write

Remote Access Group 509


book.book Page 510 Monday, March 14, 2011 3:01 PM

Remote Dial-Out PPP Password Name

Name remoteDialOutPPPPasswordName
Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.10
Description Defines the PPP password for this remote access dial-out destination.
Syntax DisplayString (SIZE (0..31))
Access Read-write

Remote Access Variable Values


This section includes definitions for server administrator-specific variable
values used in this section.

Table 20-1. Remote Access Type

Variable Name: DellRemoteAccessType


Data Type: Integer
Possible Data Values Meaning of Data Value
remoteAccessTypeIsOther(1) The remote access type is not one of
the following:
remoteAccessTypeIsUnknown(2) The remote access type is unknown.
remoteAccessTypeIsDRACIII(3) The remote access type is DRAC III.
remoteAccessTypeIsERA(4) The remote access type is ERA.

Table 20-2. Remote Access Control Capabilities

Variable Name: DellRemoteAccessControlCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The remote access hardware has no
control capabilities.
unknownCapabilities(1) The remote access hardware control
capabilities are unknown.

510 Remote Access Group


book.book Page 511 Monday, March 14, 2011 3:01 PM

Table 20-2. Remote Access Control Capabilities (continued)

Variable Name: DellRemoteAccessControlCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
logResetCapable(2) The remote access hardware can reset
its integrated logs.
hardResetCapable(4) The remote access hardware can
perform a hard reset.
softResetCapable(8) The remote access hardware can
perform a soft reset.
gracefulResetCapable(16) The remote access hardware can
gracefully shut down and perform a
soft reset.
defaultConfigResetCapable(32) The remote access hardware can reset
to its default settings.
shutdownCapable(64) The remote access hardware can
shut down.

Table 20-3. Remote Access Control Settings

Variable Name: DellRemoteAccessControlSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The remote access hardware has no control settings.
unknown(1) The remote access hardware control settings are
unknown.
logReset(2) The remote access hardware resets its
integrated logs.
hardReset(4) The remote access hardware performs a hard reset.
softReset(8) The remote access hardware performs a soft reset.
gracefulReset(16) The remote access hardware shuts down and
perform a soft reset.

Remote Access Group 511


book.book Page 512 Monday, March 14, 2011 3:01 PM

Table 20-3. Remote Access Control Settings (continued)

Variable Name: DellRemoteAccessControlSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
defaultConfigReset(32) The remote access hardware resets to its default
settings.
shutdown(64) The remote access hardware shuts down.

Table 20-4. Remote Access Monitor Capabilities

Variable Name: DellRemoteAccessMonitorCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The remote access hardware has no
monitor capabilities.
unknownCapabilities(1) The remote access hardware monitor
capabilities are unknown.
extPwrSupplyMonitorIfConn The remote access hardware can be set to
ectedCapable(2) monitor the external power supply, if
connected.
extPwrSupplyMonitorAlways The remote access hardware can be set to
EnabledCapable(4) always monitor the external power supply.

512 Remote Access Group


book.book Page 513 Monday, March 14, 2011 3:01 PM

Table 20-5. Remote Access Monitor Settings

Variable Name: DellRemoteAccessMonitorSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The remote access hardware has no
monitor settings.
unknown(1) The remote access hardware monitor settings
are unknown.
extPwrSupplyMonitorIfConn The remote access hardware monitors the
ectedEnabled(2) external power supply, if connected.
extPwrSupplyMonitorAlways The remote access hardware always monitors
EnabledEnabled(4) the external power supply.

Table 20-6. Remote Access Local Area Network (LAN) Capabilities

Variable Name: DellRemoteAccessLANCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The remote access hardware has no
LAN capabilities.
unknownCapabilities(1) The remote access hardware LAN capabilities
are unknown.
nicCapable(2) The remote access hardware has a network
interface controller (NIC).
nicDHCPCapable(4) The remote access hardware NIC can use
DHCP to obtain an IP address.

Remote Access Group 513


book.book Page 514 Monday, March 14, 2011 3:01 PM

Table 20-7. Remote Access LAN Settings

Variable Name: DellRemoteAccessLANSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The remote access hardware has no LAN
settings.
unknown(1) The remote access hardware LAN settings are
unknown.
nicEnabled(2) The remote access hardware NIC is enabled.
nicDHCPEnabled(4) The remote access hardware NIC uses DHCP
to obtain an IP address.

Table 20-8. Remote Access Host Capabilities

Variable Name: DellRemoteAccessHostCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The remote access hardware has no
host capabilities.
unknownCapabilities(1) The remote access hardware host
capabilities are unknown.
smtpEmailCapable(2) The remote access hardware
supports sending e-mail using SMTP.
tftpRemoteFloppyCapable(4) The remote access hardware supports
remote floppy boot using a TFTP server.
tftpRemoteFwUpdateCapable(8) The remote access hardware supports
remote firmware update using a TFTP
server.

514 Remote Access Group


book.book Page 515 Monday, March 14, 2011 3:01 PM

Table 20-9. Remote Access Host Settings

Variable Name: DellRemoteAccessHostSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The remote access hardware has no host
settings.
unknown(1) The remote access hardware host settings
are unknown.
smtpEmailEnabled(2) The remote access hardware SMTP client
is enabled for sending e-mail.
tftpRemoteFloppyEnabled(4) The remote access hardware TFTP client
is enabled for remote floppy boot.
tftpRemoteFwUpdateEnabled(8) The remote access hardware TFTP client
is enabled for remote firmware update.

Table 20-10. Remote Access Out-Of-Band Simple Network Management Protocol


(SNMP) Capabilities

Variable Name: DellRemoteAccessOutOfBandSNMPCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The remote access hardware has no out-of-band
SNMP capabilities.
unknownCapabilities(1) The remote access hardware out-of-band SNMP
capabilities are unknown.
oobSNMPAgentCapable(2) The remote access hardware has an out-of-band
SNMP agent.
oobSNMPTrapsCapable(4) The remote access hardware can send out-of-band
SNMP traps.

Remote Access Group 515


book.book Page 516 Monday, March 14, 2011 3:01 PM

Table 20-11. Remote Access Out-Of-Band Simple Network Management Protocol


(SNMP) Settings

Variable Name: DellRemoteAccessOutOfBandSNMPSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The remote access hardware has no out-of-band
SNMP settings.
unknown(1) The remote access hardware out-of-band SNMP
settings are unknown.
oobSNMPAgentEnabled(2) The remote access hardware out-of-band SNMP
agent is enabled.
oobSNMPTrapsEnabled(4) The remote access hardware sends out-of-band
SNMP traps.

Table 20-12. Remote User Admin State Capabilities

Variable Name: DellRemoteUserAdminStateCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The admin user has no state capabilities.
unknownCapabilities(1) The admin user state capabilities are unknown.
enableCapable(2) The admin user can be disabled or enabled.
notReadyCapable(4) The admin user can be in the not ready state.
numericPagerCapable(8) The admin user supports numeric paging.
alphaPagerCapable(16) The admin user supports alphanumeric paging.
emailCapable(32) The admin user supports e-mail.
privilegeCapable(64) The admin user supports user privileges
configuration.

516 Remote Access Group


book.book Page 517 Monday, March 14, 2011 3:01 PM

Table 20-13. Remote User Admin State Settings

Variable Name: DellRemoteUserAdminStateSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The admin user has no state settings.
unknown(1) The admin user state settings are unknown.
enabled(2) The admin user is enabled.
notReady(4) The admin user is in the not ready state.
numericPagerEnabled(8) Numeric paging is enabled for the admin user.
alphaPagerEnabled(16) Alphanumeric paging is enabled for the admin
user.
emailEnabled(32) E-mail is enabled for the admin user.

Table 20-14. Remote User Admin Control Capabilities

Variable Name: DellRemoteUserAdminControlCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The admin user has no control capabilities.
unknownCapabilities(1) The admin user control capabilities are
unknown.
numericPagerTestCapable(2) The admin user can support sending a test
numeric page.
alphaPagerTestCapable(4) The admin user can support sending a test
alphanumeric page.
emailTestCapable(8) The admin user can support sending a test
e-mail.

Remote Access Group 517


book.book Page 518 Monday, March 14, 2011 3:01 PM

Table 20-15. Remote User Admin Control Settings

Variable Name: DellRemoteUserAdminControlSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The admin user has no control settings.
unknown(1) The admin user control settings are unknown.
numericPagerTest(2) A numeric pager test is performed for the admin user.
alphaPagerTest(4) An alphanumeric pager test is performed for the
admin user.
emailTest(8) An e-mail test is performed for the admin user.

Table 20-16. Remote User Admin Alpha Protocol Type

Variable Name: DellRemoteUserAdminAlphaProtocolType


Data Type: Integer
Possible Data Values Meaning of Data Value
other(1) The remote user admin alpha protocol type is not one
of the following:
unknown(2) The remote user admin alpha protocol type is
unknown.
alpha7E0(3) The remote user admin alpha protocol type is 7E0.
alpha8N1(4) The remote user admin alpha protocol type is 8N1.

518 Remote Access Group


book.book Page 519 Monday, March 14, 2011 3:01 PM

Table 20-17. Remote User Admin Alpha Baud Type

Variable Name: DellRemoteUserAdminAlphaBaudType


Data Type: Integer
Possible Data Values Meaning of Data Value
other(1) The remote user alphanumeric baud rate is not one
of the following:
unknown(2) The remote user alphanumeric baud rate is unknown.
alphaBaud300(3) The remote user alphanumeric baud rate is 300.
alphaBaud1200(4) The remote user alphanumeric baud rate is 1200.

Table 20-18. Remote SNMP Trap State Capabilities

Variable Name: DellRemoteSNMPTrapStateCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The SNMP trap destination has no state capabilities.
unknownCapabilities The SNMP trap destination state capabilities
(1) are unknown.
enableCapable(2) The SNMP trap destination can be disabled or enabled.
notReadyCapable(4) The SNMP trap destination can be in the not ready
state.

Table 20-19. Remote SNMP Trap State Settings

Variable Name: DellRemoteSNMPTrapStateSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The SNMP trap destination has no state settings.
unknown(1) The SNMP trap destination state settings are unknown.
enabled(2) The SNMP trap destination is enabled.
notReady(4) The SNMP trap destination is in the not ready state.

Remote Access Group 519


book.book Page 520 Monday, March 14, 2011 3:01 PM

Table 20-20. Remote SNMP Trap Control Capabilities

Variable Name: DellRemoteSNMPTrapControlCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The SNMP trap destination has no control capabilities.
unknownCapabilities The SNMP trap destination control capabilities are
(1) unknown.
trapTestCapable(2) A SNMP trap test can be performed for the SNMP trap
destination.

Table 20-21. Remote SNMP Trap Control Settings

Variable Name: DellRemoteSNMPTrapControlSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The SNMP trap destination has no control settings.
unknown(1) The SNMP trap destination control settings are
unknown.
trapTestCapable(2) A SNMP trap test is performed for the SNMP trap
destination.

Table 20-22. Remote Dial-Up State Capabilities

Variable Name: DellRemoteDialUpStateCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The dial-up functionality has no
state capabilities.
unknownCapabilities(1) The dial-up functionality state
capabilities are unknown.
enableCapable(2) The dial-up functionality can be
disabled or enabled.

520 Remote Access Group


book.book Page 521 Monday, March 14, 2011 3:01 PM

Table 20-22. Remote Dial-Up State Capabilities (continued)

Variable Name: DellRemoteDialUpStateCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
notReadyCapable(4) The dial-up functionality can be in
the not ready state.
dialInCapable(8) The dial-up functionality can
support the dial-in feature.
dialOutCapable(16) The dial-up functionality can
support the dial-out feature.
dialInDHCPCapable(32) The dial-up functionality can
support using DHCP to obtain an
IP address for the dial-in feature.
dialInAuthAnyCapable(64) The dial-up functionality can support
any authentication type (including
clear text) for the dial-in feature.
dialInAuthEncryptedCapable(128) The dial-up functionality can support
encrypted passwords (CHAP)
authentication for the dial-in feature.
dialInAuthMschapCapable(256) The dial-up functionality can
support MSCHAP authentication
type for the dial-in feature.

Table 20-23. Remote Dial-Up State Settings

Variable Name: DellRemoteDialUpStateSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The dial-up functionality has no state settings.
unknown(1) The dial-up functionality state settings are unknown.
enabled(2) The dial-up functionality is enabled.
notReadyCapable(4) The dial-up functionality is in the not ready state.
dialInEnabled(8) The dial-up functionality dial-in feature is enabled.
dialOutEnabled(16) The dial-up functionality dial-out feature is enabled.

Remote Access Group 521


book.book Page 522 Monday, March 14, 2011 3:01 PM

Table 20-23. Remote Dial-Up State Settings (continued)

Variable Name: DellRemoteDialUpStateSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
dialInDHCPEnabled(32) The dial-up functionality uses DHCP to obtain an IP
address for the dial-in feature.
dialInAuthAnyEnabled The dial-up functionality accepts any authentication
(64) type (including clear text) for the dial-in feature.
dialInAuthEncrypted The dial-up functionality uses only encrypted
Enabled(128) passwords (CHAP) authentication type for the dial-
in feature.
dialInAuthMschapEnab The dial-up functionality uses only MSCHAP
led(256) authentication type for the dial-in feature.

Table 20-24. Remote Dial-Up Modem Dial Type

Variable Name: DellRemoteDialUpModemDialType


Data Type: Integer
Possible Data Values Meaning of Data Value
remoteDialUpIsOther(1) The remote dial type is not one of the
following:
remoteDialUpIsUnknown(2) The remote dial type is unknown.
remoteDialUpIsTone(3) The remote dial type is tone.
remoteDialUpIsPulse(4) The remote dial type is pulse.

522 Remote Access Group


book.book Page 523 Monday, March 14, 2011 3:01 PM

Table 20-25. Remote User Dial-In State Capabilities

Variable Name: DellRemoteUserDialInStateCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The dial-in user has no state capabilities.
unknownCapabilities(1) The dial-in user state capabilities are
unknown.
enableCapable(2) The dial-in user can be disabled or
enabled.
notReadyCapable(4) The dial-in user can be in the not ready
state.
dialInCallbackPresetNumber The dial-in user can support callback
Capable(8) using a preset number.
dialInCallbackUserSpecified The dial-in user can support callback
Capable(16) using a user-specified number.

Table 20-26. Remote User Dial-In State Settings

Variable Name: DellRemoteUserDialInStateSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The dial-in user has no state settings.
unknown(1) The dial-in user state settings are
unknown.
enabled(2) The dial-in user is enabled.
notReady(4) The dial-in user is in the not ready state.
dialInCallbackPresetNumber Callback using a preset number is
Enabled(8) enabled for the dial-in user.
dialInCallbackUserSpecified Callback using a user-specified number is
Enabled(16) enabled for the dial-in user.

Remote Access Group 523


book.book Page 524 Monday, March 14, 2011 3:01 PM

Table 20-27. Remote Dial-Out State Capabilities

Variable Name: DellRemoteDialOutStateCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The dial-out destination has no
state capabilities.
unknownCapabilities(1) The dial-out destination state
capabilities are unknown.
enableCapable(2) The dial-out destination can be
disabled or enabled.
notReadyCapable(4) The dial-out destination can be
in the not ready state.
dialOutPPPAuthAnyCapable(8) The dial-out destination can
support any authentication type
(including clear text) for PPP.
dialOutPPPAuthEncryptedCapable(16) The dial-out destination can
support encrypted passwords
authentication type for PPP.
dialOutPPPAuthMschapCapable(32) The dial-out destination can
support MSCHAP
authentication type for PPP.

524 Remote Access Group


book.book Page 525 Monday, March 14, 2011 3:01 PM

Table 20-28. Remote Dial-Out State Settings

Variable Name: DellRemoteDialOutStateSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The dial-out destination has no
state settings.
unknown(1) The dial-out destination state
settings are unknown.
enabled(2) The dial-out destination is
disabled or enabled.
notReady(4) The dial-out destination is in the
not ready state.
dialOutPPPAuthAnyEnabled(8) The dial-out destination accepts
any authentication type
(including clear text) for PPP.
dialOutPPPAuthEncryptedEnabled(16) The dial-out destination uses only
encrypted passwords
authentication type for PPP.
dialOutPPPAuthMschapEnabled(32) The dial-out destination uses only
MSCHAP authentication type for
PPP.

Remote Access Group 525


book.book Page 526 Monday, March 14, 2011 3:01 PM

526 Remote Access Group


book.book Page 527 Monday, March 14, 2011 3:01 PM

21
Cluster Group
Clustering combines multiple systems in such a way that they provide services a
single system cannot. Clustering enhances higher availability, scalability,
and management. Higher availability is achieved by using failover clusters,
in which resources can automatically move between two or more systems in the
event of a failure. Scalability is achieved by balancing the load of an application
across several computer systems. Simpler management is achieved by using
virtual servers, as opposed to managing each individual computer system.

Cluster Group
The Cluster Group defines attributes such as the number of systems in the
cluster, capabilities of the cluster, type of cluster, and name of the cluster.

Cluster Table
The following table defines the attributes of the cluster.

Name clusterTable
Object ID 1.3.6.1.4.1.674.10892.1.1800.10
Description Defines the Cluster Table.
Syntax SEQUENCE OF ClusterTableEntry
Access Not accessible

Cluster Table Entry

Name clusterTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1
Description Defines the Cluster Table entry.
Syntax ClusterTableEntry
Access Not accessible
Index clusterChassisIndex, clusterIndex

Cluster Group 527


book.book Page 528 Monday, March 14, 2011 3:01 PM

Cluster Chassis Index

Name clusterChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only

Cluster Index

Name clusterIndex
Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.2
Description Defines the index (one-based) of the cluster.
Syntax DellObjectRange
Access Read-only

Cluster State Capabilities

Name clusterStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.3
Description Defines the state capabilities of the cluster.
Syntax DellStateCapabilities
Access Read-only

Cluster State Settings

Name clusterStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.4
Description Defines the state settings of the cluster.
Syntax DellStateSettings
Access Read-write

528 Cluster Group


book.book Page 529 Monday, March 14, 2011 3:01 PM

Cluster Status

Name clusterStatus
Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.5
Description Defines the status of the cluster.
Syntax DellStatus
Access Read-only

Cluster Type

Name clusterType
Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.6
Description Defines the type of the cluster.
Syntax DellClusterType
Access Read-only

Cluster Type Description Name

Name clusterTypeDescriptionName
Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.7
Description Defines the description name for the type of the cluster.
Syntax DellString
Access Read-only

Cluster Name

Name clusterName
Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.8
Description Defines the name of the cluster.
Syntax DellString
Access Read-only

Cluster Group 529


book.book Page 530 Monday, March 14, 2011 3:01 PM

Cluster Group Variable Values


This section includes definitions for Server Administrator-specific variable
values used in this section.

Table 21-1. Cluster Type

Variable Name: DellClusterType


Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The cluster type is unknown.
highAvailabilityCluster(2) The cluster type is a high-availability cluster.

530 Cluster Group


book.book Page 531 Monday, March 14, 2011 3:01 PM

22
Baseboard Management Controller
Group
The Baseboard Management Controller (BMC) monitors the system for
critical events by communicating with various sensors on the system board
and sends alerts and log events when certain parameters exceed their preset
thresholds. The BMC Group provides information about the BMC that may
be present in your system. In addition to providing general information about
the BMC, this group provides information about the serial and local area
network (LAN) interfaces of the BMC.

Baseboard Management Controller Group Tables


The objects in the BMC group define information about the BMC and the
serial and LAN interfaces that can be used to access the BMC remotely to
perform management activities. Objects for the serial interface define the
serial connection mode, flow control type and bit rate. Objects for the LAN
interface define the media access control (MAC) address, internet protocol
(IP) address, subnet mask and default gateway.
The following MIB tables define the BMC group:
• Baseboard Management Controller Table
• Baseboard Management Controller Serial Interface Table
• Baseboard Management Controller LAN Interface Table

Baseboard Management Controller Table

Name bmcTable
Object ID 1.3.6.1.4.1.674.10892.1.1900.10
Description Defines the Baseboard Management Controller Table.
Syntax SEQUENCE OF BmcTableEntry
Access Not accessible

Baseboard Management Controller Group 531


book.book Page 532 Monday, March 14, 2011 3:01 PM

BMC Table Entry

Name bmcTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1
Description Defines the Baseboard Management Controller (BMC) Table Entry.
Syntax BmcTableEntry
Access Not accessible
Index bmcChassisIndex, bmcIndex

BMC Chassis Index

Name bmcChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellObjectRange
Access Read-only

BMC Index

Name bmcIndex
Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.2
Description Defines the index (one-based) of the BMC.
Syntax DellObjectRange
Access Read-only

BMC State Capabilities

Name bmcStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.3
Description Defines the state capabilities of the BMC.
Syntax DellStateCapabilities
Access Read-only

532 Baseboard Management Controller Group


book.book Page 533 Monday, March 14, 2011 3:01 PM

BMC State Settings

Name bmcStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.4
Description Defines the state settings of the BMC.
Syntax DellStateSettings
Access Read-write

BMC Status

Name bmcStatus
Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.5
Description Defines the status of the BMC.
Syntax DellStatus
Access Read-only

BMC Display Name

Name bmcDisplayName
Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.6
Description Defines the display name of the BMC.
Syntax DellString
Access Read-only

BMC Description Name

Name bmcDescriptionName
Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.7
Description Defines the description of the BMC.
Syntax DisplayString (SIZE (0..255))
Access Read-only

Baseboard Management Controller Group 533


book.book Page 534 Monday, March 14, 2011 3:01 PM

BMC IPMI Version Name

Name bmcIPMIVersionName
Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.8
Description Defines the version of the Intelligent Platform Management
Interface (IPMI) specification that the BMC supports.
Syntax DellString
Access Read-only

BMC GUID

Name bmcGUID
Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.9
Description Defines the Globally Unique ID (GUID) of the BMC.
Syntax Octet String (SIZE(16))
Access Read-only

BMC Type

Name bmcType
Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.10
Description Defines the type of the BMC.
Syntax DellManagementControllerType
Access Read-only

BMC Module Name

Name bmcModuleName
Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.11
Description Defines the module name for the BMC. The module name is
present only on certain systems, such as modular systems.
Syntax DellString
Access Read-only

534 Baseboard Management Controller Group


book.book Page 535 Monday, March 14, 2011 3:01 PM

BMC IPv4 URL Name


Name bmcIPv4URLName
Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.12
Description Defines the IPv4 URL for the BMC. The URL is not present on
all systems.
Syntax DisplayString (SIZE (0..1024))
Access Read-only

BMC IPv6 URL Name


Name bmcIPv6URLName
Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.13
Description Defines the IPv6 URL for the BMC. The URL is not present on
all systems.
Syntax DisplayString (SIZE (0..1024))
Access Read-only

Baseboard Management Controller Serial Interface Table

Name bmcSerialInterfaceTable
Object ID 1.3.6.1.4.1.674.10892.1.1900.20
Description Defines the BMC Serial Interface Table.
Syntax SEQUENCE OF BmcSerialInterfaceTableEntry
Access Not accessible

Baseboard Management Controller Group 535


book.book Page 536 Monday, March 14, 2011 3:01 PM

BMC Serial Interface Table Entry

Name bmcSerialInterfaceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1
Description Defines the BMC Serial Interface Table Entry.
Syntax BmcSerialInterfaceTableEntry
Access Not accessible
Index bmcSerialInterfaceChassisIndex,
bmcSerialInterfaceBMCIndex, bmcSerialInterfaceIndex

BMC Serial Interface Chassis Index

Name bmcSerialInterfaceChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellObjectRange
Access Read-only

BMC Serial Interface BMC Index

Name bmcSerialInterfaceBMCIndex
Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.2
Description Defines the index (one-based) of the associated BMC.
Syntax DellObjectRange
Access Read-only

BMC Serial Interface Index

Name bmcSerialInterfaceIndex
Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.3
Description Defines the index (one-based) of the BMC serial interface.
Syntax DellObjectRange
Access Read-only

536 Baseboard Management Controller Group


book.book Page 537 Monday, March 14, 2011 3:01 PM

BMC Serial Interface State Capabilities

Name bmcSerialInterfaceStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.4
Description Defines the state capabilities of the BMC serial interface.
Syntax DellStateCapabilities
Access Read-only

BMC Serial Interface State Settings

Name bmcSerialInterfaceStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.5
Description Defines the state settings of the BMC serial interface.
Syntax DellStateSettings
Access Read-write

BMC Serial Interface Status

Name bmcSerialInterfaceStatus
Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.6
Description Defines the status of the BMC serial interface.
Syntax DellStatus
Access Read-only

BMC Serial Interface Channel Number

Name bmcSerialInterfaceChannelNumber
Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.7
Description Defines the BMC channel number of the BMC serial interface.
Syntax DellUnsigned8BitRange
Access Read-only

Baseboard Management Controller Group 537


book.book Page 538 Monday, March 14, 2011 3:01 PM

BMC Serial Interface Connection Mode Capabilities

Name bmcSerialInterfaceConnectionModeCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.8
Description Defines the connection mode capabilities of the BMC serial
interface.
Syntax DellBMCSerialConnectionModeCapabilities
Access Read-only

BMC Serial Interface Connection Mode Settings

Name bmcSerialInterfaceConnectionModeSettings
Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.9
Description Defines the connection mode settings of the BMC serial
interface.
Syntax DellBMCSerialConnectionModeSettings
Access Read-only

BMC Serial Interface Flow Control

Name bmcSerialInterfaceFlowControl
Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.10
Description Defines the flow control type of the BMC serial interface.
Syntax DellBMCSerialFlowControlType
Access Read-only

BMC Serial Interface Bit Rate

Name bmcSerialInterfaceBitRate
Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.11
Description Defines the bit rate of the BMC serial interface.
Syntax DellBMCSerialBitRateType
Access Read-only

538 Baseboard Management Controller Group


book.book Page 539 Monday, March 14, 2011 3:01 PM

Baseboard Management Controller LAN Interface Table

Name bmcLANInterfaceTable
Object ID 1.3.6.1.4.1.674.10892.1.1900.30
Description Defines the Baseboard Management Controller (BMC) LAN
Interface Table.
Syntax SEQUENCE OF BmcLANInterfaceTableEntry
Access Not accessible

BMC LAN Interface Table Entry

Name bmcLANInterfaceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1
Description Defines the Baseboard Management Controller (BMC) LAN
Interface Table Entry.
Syntax BmcLANInterfaceTableEntry
Access Not accessible
Index bmcLANInterfaceChassisIndex, bmcLANInterfaceBMCIndex,
bmcLANInterfaceIndex

BMC LAN Interface Chassis Index

Name bmcLANInterfaceChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellObjectRange
Access Read-only

Baseboard Management Controller Group 539


book.book Page 540 Monday, March 14, 2011 3:01 PM

BMC LAN Interface BMC Index

Name bmcLANInterfaceBMCIndex
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.2
Description Defines the index (one-based) of the associated BMC.
Syntax DellObjectRange
Access Read-only

BMC LAN Interface Index

Name bmcLANInterfaceIndex
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.3
Description Defines the index (one-based) of the BMC LAN interface.
Syntax DellObjectRange
Access Read-only

BMC LAN Interface State Capabilities

Name bmcLANInterfaceStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.4
Description Defines the state capabilities of the BMC LAN interface.
Syntax DellStateCapabilities
Access Read-only

BMC LAN Interface State Settings

Name bmcLANInterfaceStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.5
Description Defines the state settings of the BMC LAN interface.
Syntax DellStateSettings
Access Read-write

540 Baseboard Management Controller Group


book.book Page 541 Monday, March 14, 2011 3:01 PM

BMC LAN Interface Status

Name bmcLANInterfaceStatus
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.6
Description Defines the status of the BMC LAN interface.
Syntax DellStatus
Access Read-only

BMC LAN Interface Channel Number

Name bmcLANInterfaceChannelNumber
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.7
Description Defines the BMC channel number of the BMC LAN interface.
Syntax DellUnsigned8BitRange
Access Read-only

BMC LAN Interface IP Address Source

Name bmcLANInterfaceIPAddressSource
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.8
Description Defines the source type of the IP address of the BMC LAN
interface.
Syntax DellBMCLANIPAddressSourceType
Access Read-only

BMC LAN Interface IP Address

Name bmcLANInterfaceIPAddress
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.9
Description Defines the IP address of the BMC LAN interface.
Syntax IpAddress
Access Read-only

Baseboard Management Controller Group 541


book.book Page 542 Monday, March 14, 2011 3:01 PM

BMC LAN Interface Subnet Mask Address

Name bmcLANInterfaceSubnetMaskAddress
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.10
Description Defines the subnet mask of the BMC LAN interface.
Syntax IpAddress
Access Read-only

BMC LAN Interface Default Gateway Address

Name bmcLANInterfaceDefaultGatewayAddress
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.11
Description Defines the IP address of the default gateway for the BMC LAN
interface.
Syntax IpAddress
Access Read-only

BMC LAN Interface MAC Address

Name bmcLANInterfaceMACAddress
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.12
Description Defines the MAC address of the BMC LAN interface.
Syntax DellMACAddress
Access Read-only

BMC LAN Interface Alert Community Name

Name bmcLANInterfaceAlertCommunityName
Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.13
Description Defines the SNMP community used for BMC LAN alerts
(traps) sent on the BMC LAN interface.
Syntax DisplayString (SIZE (0..32))
Access Read-only

542 Baseboard Management Controller Group


book.book Page 543 Monday, March 14, 2011 3:01 PM

Baseboard Management Controller Group


Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 22-1. BMC Serial Connection Mode Capabilities

Variable Name: DellBMCSerialConnectionModeCapabilities


Data Type: Integer
These values are bit masks; therefore, combination values are possible.
Possible Data Values Meaning of Data Value
-- none(0) No mode capabilities.
modemBasic(1) BMC serial interface supports Modem Basic mode.
modemPPP(2) BMC serial interface supports Modem Point to Point
Protocol (PPP) mode.
modemTerminal(4) BMC serial interface supports Modem Terminal mode.
directBasic(8) BMC serial interface supports Direct Basic mode.
directPPP(16) BMC serial interface supports Direct PPP mode.
directTerminal(32) BMC serial interface supports Direct Terminal mode.

Table 22-2. BMC Serial Connection Mode Settings

Variable Name: DellBMCSerialConnectionModeSettings


Data Type: Integer
These values are bit masks; therefore, combination values are possible.
Possible Data Values Meaning of Data Value
-- none(0) No modes enabled.
modemBasic(1) Modem Basic mode is enabled.
modemPPP(2) Modem PPP mode is enabled.
modemTerminal(4) Modem Terminal mode is enabled.
directBasic(8) Direct Basic mode is enabled.
directPPP(16) Direct PPP mode is enabled.
directTerminal(32) Direct Terminal mode is enabled.

Baseboard Management Controller Group 543


book.book Page 544 Monday, March 14, 2011 3:01 PM

Table 22-3. BMC Serial Flow Control Type

Variable Name: DellBMCSerialFlowControlType


Data Type: Integer
Possible Data Values Meaning of Data Value
-- none(0) No flow control used.
rtscts(1) RTS/CTS (hardware) flow control used.
xonXoff(2) XON/XOFF flow control used.

Table 22-4. BMC Serial Bit Rate Type

Variable Name: DellBMCSerialBitRateType


Data Type: Integer
Possible Data Values Meaning of Data Value
bps9600(6) Bit rate is 9600 bps (bits per second)
bps19200(7) Bit rate is 19200 bps
bps38400(8) Bit rate is 38400 bps
bps57600(9) Bit rate is 57600 bps
bps115200(10) Bit rate is 115200 bps

Table 22-5. BMC LAN IP Address Source Type

Variable Name: DellBMCLANIPAddressSourceType


Data Type: Integer
Possible Data Values Meaning of Data Value
-- unspecified(0) Source is unspecified.
static(1) IP address is static.
dhcp(2) Dynamic Host Configuration Protocol (DHCP)
used to obtain IP address.
biosOrSystemSoftware(3) BIOS or system software provided IP Address.
other(4) Other protocol used to obtain IP address.

544 Baseboard Management Controller Group


book.book Page 545 Monday, March 14, 2011 3:01 PM

Table 22-6. BMC Management Controller Type

Variable Name: DellManagementControllerType


Data Type: Integer
Possible Data Values Meaning of Data Value
-- legacyBMC(0) Controller type is legacy Baseboard
Management Controller.
iDRAC(8) Controller type is iDRAC.
iDRAC6(10) Controller type is Integrated
Dell Remote Access Controller 6
iDRAC6Modular(11) Controller type is Integrated Dell
Remote Access Controller 6 (Modular)
iDRAC6BMC(13) Controller type is Integrated
Dell Remote Access Controller 6
(BMC mode)

Baseboard Management Controller Group 545


book.book Page 546 Monday, March 14, 2011 3:01 PM

546 Baseboard Management Controller Group


book.book Page 547 Monday, March 14, 2011 3:01 PM

23
Field Replaceable Unit Group
A field replaceable unit (FRU) is a part that can be removed and replaced
without having to send the system to a repair facility. The Field Replaceable
Unit Group provides information about the field replaceable units that may
be present in your system.

Field Replaceable Unit Group Tables


The objects in the FRU group define information such as manufacturer,
serial number, part number and revision for field replaceable units.
The following MIB tables define the FRU group.

Field Replaceable Unit Table

Name fruTable
Object ID 1.3.6.1.4.1.674.10892.1.2000.10
Description Defines the Field Replaceable Unit table.
Syntax SEQUENCE OF FruTableEntry
Access Not accessible

FRU Table Entry

Name fruTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1
Description Defines the FRU Table Entry.
Syntax FruTableEntry
Access Not accessible
Index fruChassisIndex, fruIndex

Field Replaceable Unit Group 547


book.book Page 548 Monday, March 14, 2011 3:01 PM

FRU Chassis Index

Name fruChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.1
Description Defines the index (one-based) of the chassis containing the
FRU.
Syntax DellObjectRange
Access Read-only

FRU Index

Name fruIndex
Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.2
Description Defines the index (one-based) of the FRU.
Syntax DellObjectRange
Access Read-only

FRU Information Status

Name fruInformationStatus
Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.3
Description Defines the status of the FRU table entry.
Syntax DellStatus
Access Read-only

FRU Information State

Name fruInformationState
Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.4
Description Defines the state of the FRU information. Some information for
the FRU may not be available if the state is other than ok(1).
Syntax DellFRUInformationState
Access Read-only

548 Field Replaceable Unit Group


book.book Page 549 Monday, March 14, 2011 3:01 PM

FRU Device Name

Name fruDeviceName
Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.5
Description Defines the device name of the FRU.
Syntax DisplayString (SIZE (0..64))
Access Read-only

FRU Manufacturer Name

Name fruManufacturerName
Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.6
Description Defines the manufacturer of the FRU.
Syntax DisplayString (SIZE (0..64))
Access Read-only

FRU Serial Number Name

Name fruSerialNumberName
Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.7
Description Defines the serial number of the FRU.
Syntax DisplayString (SIZE (0..64))
Access Read-only

FRU Part Number Name

Name fruPartNumberName
Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.8
Description Defines the part number of the FRU
Syntax DisplayString (SIZE (0..64))
Access Read-only

Field Replaceable Unit Group 549


book.book Page 550 Monday, March 14, 2011 3:01 PM

FRU Revision Name

Name fruRevisionName
Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.9
Description Defines the revision of the FRU.
Syntax DisplayString (SIZE (0..64))
Access Read-only

FRU Manufacturing Date Name

Name fruManufacturingDateName
Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.10
Description Defines the manufacturing date of the FRU.
Syntax DellDateName
Access Read-only

FRU Asset Tag Name

Name fruAssetTagName
Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.11
Description Defines the asset tag of the FRU.
Syntax DisplayString (SIZE (0..64))
Access Read-only

550 Field Replaceable Unit Group


book.book Page 551 Monday, March 14, 2011 3:01 PM

Field Replaceable Unit Group Variable Values


This section includes definitions for server administrator-specific variable
values.

Table 23-1. FRU Information State

Variable Name: DellFRUInformationState


Data Type: Integer
Possible Data Values Meaning of Data Value
ok(1) FRU information is okay.
notSupported(2) FRU information is not supported.
notAvailable(3) FRU information is not available.
checksumInvalid(4) FRU information checksum is invalid.
corrupted(5) FRU information is corrupted.

Field Replaceable Unit Group 551


book.book Page 552 Monday, March 14, 2011 3:01 PM

552 Field Replaceable Unit Group


book.book Page 553 Monday, March 14, 2011 3:01 PM

24
Storage Management Group
The Storage Management Group is composed of the following:
• Storage Management Group—information about the software product
and system status.
• Storage Management Information Group—properties about the Simple
Network Management Protocol (SNMP) agent.
• Global Data Group—system status.
• Physical Devices Group—physical devices managed by the software.
• Logical Devices Group—logical devices managed by the software.
• Storage Management Event Group—SNMP traps.

Storage Management Group


The Storage Management Information Base (MIB) Group defines the
properties that identify information about the Storage Management software
product and the current status of the system it manages.

Software Version

Name softwareVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.1
Description Identifies the version number of the storage management
component of the systems management software.
Syntax DisplayString
Access Read-only

Storage Management Group 553


book.book Page 554 Monday, March 14, 2011 3:01 PM

Global Status

Name globalStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.2
Description Identifies global health for the subsystem managed by the Storage
Management software. This global status is customized for HP
OpenView. Other applications should refer to the
agentSystemGlobalStatus entry in the globalData object group.
Possible values:
1: Critical
2: Warning
3: Normal
4: Unknown
Syntax Integer
Access Read-only

Software Manufacturer

Name softwareManufacturer
Object ID 1.3.6.1.4.1.674.10893.1.20.3
Description Identifies the manufacturer of the Storage Management software.
Syntax DisplayString
Access Read-only

Software Product

Name softwareProduct
Object ID 1.3.6.1.4.1.674.10893.1.20.4
Description Identifies product information for the Storage Management
software.
Syntax DisplayString
Access Read-only

554 Storage Management Group


book.book Page 555 Monday, March 14, 2011 3:01 PM

Software Description

Name softwareDescription
Object ID 1.3.6.1.4.1.674.10893.1.20.5
Description Identifies the product description for the Storage Management
software.
Syntax DisplayString
Access Read-only

Storage Management Information Group


The Storage Management Information MIB Group defines the properties
that identify the Storage Management software SNMP agent.

Display Name

Name displayName
Object ID 1.3.6.1.4.1.674.10893.1.20.100.1
Description Identifies the name of this management software for display
purposes.
Syntax DisplayString
Access Read-only

Description

Name description
Object ID 1.3.6.1.4.1.674.10893.1.20.100.2
Description Provides a short description of this management software.
Syntax DisplayString
Access Read-only

Storage Management Group 555


book.book Page 556 Monday, March 14, 2011 3:01 PM

Agent Vendor

Name agentVendor
Object ID 1.3.6.1.4.1.674.10893.1.20.100.3
Description Identifies the name of the management software manufacturer.
Syntax DisplayString
Access Read-only

Agent Version

Name agentVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.100.4
Description This entry is obsolete. Refer to softwareVersion.
Syntax DisplayString
Access Read-only

Global Data Group


The Global Data Management Information Base (MIB) Group defines the
properties that identify status information about the system that the Storage
Management software is managing and about the Storage Management
SNMP agent.

Agent System Global Status

Name agentSystemGlobalStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.110.1
Description This entry is obsolete. Use the value agentGlobalSystemStatus.
Syntax Integer
Access Read-only

556 Storage Management Group


book.book Page 557 Monday, March 14, 2011 3:01 PM

Agent Last Global Status

Name agentLastGlobalStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.110.2
Description This entry is obsolete. Use the value
agentLastGlobalSystemStatus.
Syntax Integer
Access Read-only

Agent Time Stamp

Name agentTimeStamp
Object ID 1.3.6.1.4.1.674.10893.1.20.110.3
Description Identifies the last time that the agent values have been updated.
Universal time in sec since UTC 1/1/70.
Syntax Integer
Access Read-only

Agent Get Timeout

Name agentGetTimeout
Object ID 1.3.6.1.4.1.674.10893.1.20.110.4
Description Indicates the suggested timeout value in milliseconds for how long
the SNMP getter should wait while attempting to poll the SNMP
agent.
Syntax Integer
Access Read-only

Storage Management Group 557


book.book Page 558 Monday, March 14, 2011 3:01 PM

Agent Modifiers

Name agentModifiers
Object ID 1.3.6.1.4.1.674.10893.1.20.110.5
Description Identifies the agent functional modifiers. When set, the modifier
is active. Bit definitions:
Bit 3: agent in debug mode.
All other bits are product specific.
Syntax Integer
Access Read-only

Agent Refresh Rate

Name agentRefreshRate
Object ID 1.3.6.1.4.1.674.10893.1.20.110.6
Description Identifies the rate, given in seconds, at which the cached data for
SNMP is refreshed. The default value is 300 seconds, or 5 minutes.
Syntax Integer
Access Read-only

Agent Hostname

Name agentHostname
Object ID 1.3.6.1.4.1.674.10893.1.20.110.7
Description This entry is obsolete for Storage Management.
Syntax DisplayString
Access Read-only

558 Storage Management Group


book.book Page 559 Monday, March 14, 2011 3:01 PM

Agent IP Address

Name agentIPAddress
Object ID 1.3.6.1.4.1.674.10893.1.20.110.8
Description This entry is obsolete for Storage Management.
Syntax DisplayString
Access Read-only

Agent Software Status

Name agentSoftwareStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.110.9
Description This entry is obsolete for Storage Management.
Syntax DisplayString
Access Read-only

Agent SNMP Version

Name agentSnmpVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.110.10
Description This entry is obsolete. Refer to 0001 softwareVersion.
Syntax DisplayString
Access Read-only

Agent MIB Version

Name agentMibVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.110.11
Description Identifies the version of the Storage Management MIB.
Syntax DisplayString
Access Read-only

Storage Management Group 559


book.book Page 560 Monday, March 14, 2011 3:01 PM

Agent Management Software URL Name

Name agentManagementSoftwareURLName
Object ID 1.3.6.1.4.1.674.10893.1.20.110.12
Description Identifies the Universal Resource Locator (URL) of the systems
management software.
Syntax DisplayString
Access Read-only

Agent Global System Status

Name agentGlobalSystemStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.110.13
Description Global health information for the subsystem managed by the
Storage Management software. This global status should be used
by applications other than HP OpenView. HP OpenView should
refer to the globalStatus in the root level object group. This is a
rollup for the entire agent including any monitored devices. The
status is intended to give initiative to an SNMP monitor to get
further data when this status is abnormal. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

560 Storage Management Group


book.book Page 561 Monday, March 14, 2011 3:01 PM

Agent Last Global System Status

Name agentLastGlobalSystemStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.110.14
Description The previous global status of the system managed by the Storage
Management software. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Agent Smart Thermal Shutdown

Name agentSmartThermalShutdown
Object ID 1.3.6.1.4.1.674.10893.1.20.110.15
Description Indicates the status of smart thermal shutdown for PowerVault
220S and PowerVault 221S enclosures.
Possible values:
1: Enabled
2: Disabled
3: Not applicable
Syntax Integer
Access Read-only

Storage Management Group 561


book.book Page 562 Monday, March 14, 2011 3:01 PM

Physical Devices Group


The Physical Devices MIB group provides information about the devices
managed by the Storage Management software and their relationships to each
other. The following MIB tables define objects and relationships
(connections) among the objects.
• Controller Table—describes available properties for each controller on the
managed system.
• Channel Table—describes available properties for each channel on the
managed system.
• Enclosure Table—describes available properties for each enclosure on the
managed system.
• Array Disk Table—describes available properties for each physical array
disk on the managed system.
• Array Disk Enclosure Connection Table—describes the connections
between Fibre Channel array disks, their enclosure, and their associated
controller. For each object in the table, its object number corresponds to an
instance number in the appropriate MIB table for that object where all of
the object properties can be found.
• Array Disk Channel Connection Table—describes the connections
between SCSI array disks, their channel, and their associated controller.
For each object in the table, its object number corresponds to an instance
number in the appropriate MIB table for that object where all of the object
properties can be found.
• Fan Table—describes available properties for each fan on the managed
system.
• Fan Connection Table—describes the connection between each fan on
the managed system and its enclosure. Each enclosure number in the table
corresponds to that enclosure instance in the Enclosure Table.
• Power Supply Table—describes available properties for each power supply
on the managed system.
• Power Supply Connection Table—describes the connection between each
power supply on the managed system and its enclosure. Each enclosure
number in the table corresponds to that enclosure instance in the
Enclosure Table.

562 Storage Management Group


book.book Page 563 Monday, March 14, 2011 3:01 PM

• Temperature Probe Table—describes available properties for each


temperature probe on the managed system.
• Temperature Probe Connection Table—describes the connection
between each temperature probe on the managed system and its
enclosure. Each enclosure number in the table corresponds to that
enclosure instance in the Enclosure Table.
• EMM Table—describes available properties for each Enclosure
Management Module (EMM) on the managed system.
• EMM Connection Table—describes the connection between each EMM
on the managed system and its enclosure. Each enclosure number in the
table corresponds to that enclosure instance in the Enclosure Table.
• Battery Table—describes available properties for each controller battery on
the managed system.
• Battery Connection Table—describes the connection between each
battery on the managed system and its controller. Each controller number
in the table corresponds to that controller instance in the Controller Table.

Controller Table
This table describes available properties for each controller on the managed
system.
The following object sets up the Controller Table.

Name controllerTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1
Description Defines the controller table, which is a table of managed
Redundant Array of Independent disks (RAID) controllers. The
number of entries is related to the number of RAID controllers
discovered in the system.
Syntax SEQUENCE OF ControllerEntry
Access Not accessible

Storage Management Group 563


book.book Page 564 Monday, March 14, 2011 3:01 PM

Controller Entry

Name controllerEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1
Description Defines the controller table entry, which is an entry in the table of
RAID controllers. A row in this table cannot be created or deleted
by SNMP operations on columns of the table.
Syntax ControllerEntry
Access Not accessible
Index controllerNumber

Controller Number

Name controllerNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.1
Description Identifies the instance number of the controller entry.
Syntax Integer
Access Read-only

Controller Name

Name controllerName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.2
Description Identifies the name of the controller in this subsystem as
represented in Storage Management. Includes the controller type
and instance. For example: PERC 3/QC 1.
Syntax DisplayString
Access Read-only

564 Storage Management Group


book.book Page 565 Monday, March 14, 2011 3:01 PM

Controller Vendor

Name controllerVendor
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3
Description Identifies the controller's (re)seller's name.
Syntax DisplayString
Access Read-only

Controller Type

Name controllerType
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.4
Description Identifies the type of this controller:
1: SCSI
2: PowerVault 660F
3: Power Vault 662F
4: Integrated/Intelligent Drive Electronics (IDE)
5: Serial Advanced Technology Architecture (SATA)
6: Serial Attached SCSI (SAS)
Syntax Integer
Access Read-only

Controller State

Name controllerState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.5
Description Identifies the status of the controller's subsystem (which includes
any devices connected to it). Possible states:
0: Unknown, 1: Ready, 2: Failed, 3: Online, 4: Offline, 6: Degraded
Syntax Integer
Access Read-only

Storage Management Group 565


book.book Page 566 Monday, March 14, 2011 3:01 PM

Controller Severity

Name controllerSeverity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.6
Description This entry is obsolete for Storage Management. It was replaced
with RollUpStatus and ComponentStatus for each device.
Syntax Integer
Access Read-only

Controller Rebuild Rate in Percent

Name controllerRebuildRateInPercent
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.7
Description Identifies the percent of the compute cycles dedicated to
rebuilding failed array disks.
Syntax Integer
Access Read-only

Controller Firmware Version

Name controllerFWVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.8
Description Identifies the controller's current firmware version.
Syntax DisplayString
Access Read-only

Controller Cache Size in Megabytes

Name controllerCacheSizeInMB
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.9
Description Identifies the controller's current amount of cache memory in
megabytes. If this size is 0, it is less than a megabyte.
Syntax Integer
Access Read-only

566 Storage Management Group


book.book Page 567 Monday, March 14, 2011 3:01 PM

Controller Cache Size in Bytes

Name controllerCacheSizeInBytes
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.10
Description Identifies the controller's current amount of cache memory that is
less than a megabyte. This combined with the
controllerCacheSizeInMB is the total amount of memory.
Syntax Integer
Access Read-only

Controller Physical Device Count

Name controllerPhysicalDeviceCount
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.11
Description Identifies the number of physical devices on the controller
channel including both disks and the controller.
Syntax Integer
Access Read-only

Controller Logical Device Count

Name controllerLogicalDeviceCount
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.12
Description Identifies the number of virtual disks on the controller.
Syntax Integer
Access Read-only

Controller Partner Status

Name controllerPartnerStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.13
Description This entry is obsolete for Storage Management.
Syntax DisplayString
Access Read-only

Storage Management Group 567


book.book Page 568 Monday, March 14, 2011 3:01 PM

Controller Host Port Count

Name controllerHostPortCount
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.14
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax Integer
Access Read-only

Controller Memory Size in Megabytes

Name controllerMemorySizeInMB
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.15
Description Identifies the size of memory in megabytes on the controller. If
this size is 0, it is less than a megabyte. This attribute is only
supported on Adaptec controllers.
Syntax Integer
Access Read-only

Controller Memory Size in Bytes

Name controllerMemorySizeInBytes
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.16
Description Identifies the size of memory on the controller that is less than a
megabyte. This combined with the controllerMemorySizeInMB is
the total size of the memory. This attribute is only supported on
Adaptec controllers.
Syntax Integer
Access Read-only

Controller Drive Channel Count

Name controllerDriveChannelCount
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.17

568 Storage Management Group


book.book Page 569 Monday, March 14, 2011 3:01 PM

Name controllerDriveChannelCount
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax Integer
Access Read-only

Controller Fault Tolerant

Name controllerFaultTolerant
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.18
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax Integer
Access Read-only

Controller C0 Port 0 World Wide Name

Name controllerC0Port0WorldWideName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.19
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax DisplayString
Access Read-only

Controller C0 Port 0 Name

Name controllerC0Port0Name
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.20
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax DisplayString
Access Read-only

Storage Management Group 569


book.book Page 570 Monday, March 14, 2011 3:01 PM

Controller C0 Port 0 ID

Name controllerC0Port0ID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.21
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax Integer
Access Read-only

Controller C0 Target

Name controllerC0Target
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.22
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax Integer
Access Read-only

Controller C0 Channel

Name controllerC0Channel
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.23
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax Integer
Access Read-only

Controller C0 Operating System Controller

Name controllerC0OSController
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.24
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax DisplayString
Access Read-only

570 Storage Management Group


book.book Page 571 Monday, March 14, 2011 3:01 PM

Controller C0 Battery State

Name controllerC0BatteryState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.25
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax Integer
Access Read-only

Controller C1 Port 0 World Wide Name

Name controllerC1Port0WWN
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.26
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax DisplayString
Access Read-only

Controller C1 Port 0 Name

Name controllerC1Port0Name
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.27
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax DisplayString
Access Read-only

Controller C1 Port 0 ID

Name controllerC1Port0ID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.28
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax Integer
Access Read-only

Storage Management Group 571


book.book Page 572 Monday, March 14, 2011 3:01 PM

Controller C1 Target

Name controllerC1Target
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.29
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax Integer
Access Read-only

Controller C1 Channel

Name controllerC1Channel
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.30
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax Integer
Access Read-only

Controller C1 Operating System Controller

Name controllerC1OSController
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.31
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax DisplayString
Access Read-only

Controller Battery State C1

Name controllerC1BatteryState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.32
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax Integer
Access Read-only

572 Storage Management Group


book.book Page 573 Monday, March 14, 2011 3:01 PM

Controller Node World Wide Name

Name controllerNodeWWN
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.33
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax DisplayString
Access Read-only

Controller C0 Port 1 World Wide Name

Name controllerC0Port1WWN
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.34
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax DisplayString
Access Read-only

Controller C1 Port 1 World Wide Name

Name controllerC1Port1WWN
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.35
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax DisplayString
Access Read-only

Controller Battery Charge Count

Name controllerBatteryChargeCount
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.36
Description This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax Integer

Storage Management Group 573


book.book Page 574 Monday, March 14, 2011 3:01 PM

Name controllerBatteryChargeCount
Access Read-only

Controller Roll-Up Status

Name controllerRollUpStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.37
Description Indicates severity of the controller state. This is the combined
status of the controller and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Controller Component Status

Name controllerComponentStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.38
Description Indicates the status of the controller itself without the propagation
of any contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

574 Storage Management Group


book.book Page 575 Monday, March 14, 2011 3:01 PM

Controller Nexus ID

Name controllerNexusID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.39
Description Durable unique ID for this controller.
Syntax DisplayString
Access Read-only

Controller Alarm State

Name controllerAlarmState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.40
Description Indicates state, or setting for the controller's alarm. Possible
values:
1: Enabled
2: Disabled
3: Not Applicable
Syntax Integer
Access Read-only

Controller Driver Version

Name controllerDriverVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.41
Description Indicates currently installed driver version of the controller
Syntax DisplayString
Access Read-only

Controller PCI Slot

Name controllerPCISlot
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.42
Description Indicates the PCI slot number or embedded number for
controllers on the motherboard

Storage Management Group 575


book.book Page 576 Monday, March 14, 2011 3:01 PM

Name controllerPCISlot
Syntax DisplayString
Access Read-only

Controller Cluster Mode

Name controllerClusterMode
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.43
Description Identifies if the controller is in cluster mode.
Possible values:
1: Enabled
2: Disabled
3: Active (enabled and active)
99: Not Applicable
Syntax Integer
Access Read-only

Controller Minimum Firmware Version

Name controllerMinFWVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.44
Description The minimum firmware version for Storage Management to
support the controller.
Syntax DisplayString
Access Read-only

Controller Minimum Driver Version

Name controllerMinDriverVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.45
Description The minimum driver version for Storage Management to support
the controller.
Syntax DisplayString

576 Storage Management Group


book.book Page 577 Monday, March 14, 2011 3:01 PM

Name controllerMinDriverVersion
Access Read-write

Controller SCSI Initiator ID

Name controllerSCSIInitiatorID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.46
Description The SCSI ID of the initiator.
Syntax Integer
Access Read-only

Controller Channel Count

Name controllerChannelCount
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.47
Description The number of channels on the controller.
Syntax Integer
Access Read-only

Controller Reconstruct Rate

Name controllerReconstructRate
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.48
Description The rate for reconstruct on the controller.
Syntax Integer
Access Read-write

Controller Patrol Read Rate

Name controllerPatrolReadRate
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.49
Description The rate for patrol read on the controller.
Syntax Integer

Storage Management Group 577


book.book Page 578 Monday, March 14, 2011 3:01 PM

Name controllerPatrolReadRate
Access Read-only

Controller BGI Rate

Name controllerBGIRate
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.50
Description The rate for background initialization on the controller.
Syntax Integer
Access Read-only

Controller Check Consistency Rate

Name controllerCheckConsistencyRate
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.51
Description The rate for check consistency on the controller.
Syntax Integer
Access Read-only

Controller Patrol Read Mode

Name controllerPatrolReadMode
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.52
Description Identifies the patrol read mode.
Possible values:
1: Automatic (enabled)
2: Manual (enabled)
3: Disabled
Syntax Integer
Access Read-only

578 Storage Management Group


book.book Page 579 Monday, March 14, 2011 3:01 PM

Controller Patrol Read State

Name controllerPatrolReadState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.53
Description The state of the patrol read.
Possible values:
1: Stopped - not running
2: Ready - ready to start
4: Active - is running
8: Aborted - has aborted
Syntax Integer
Access Read-only

Controller Patrol Read Iterations

Name controllerPatrolReadIterations
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.54
Description The number of times Patrol Read has been run on this controller.
Syntax Integer
Access Read-only

Controller Storport Driver Version

Name controllerStorportDriverVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.55
Description Provides current Windows OS storport driver version. Not
applicable for Linux.
Syntax Octet String
Access Read-only

Storage Management Group 579


book.book Page 580 Monday, March 14, 2011 3:01 PM

Controller Minimum Required Storport Version

Name controllerMinimumRequiredStorportVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.56
Description Provides minimum required storport driver version for Windows
OS only.
Syntax Octet String
Access Read-only

Controller Encryption Capable


Name controllerEncryptionCapable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.57
Description Indicates encryption capability of the controller.
Value: 1 - Capable, 99 - Not Applicable
Syntax Integer
Access Read-only

Controller Encryption Key Present


Name controllerEncryptionKeyPresent
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.58
Description Indicates presence of encryption key for the controller.
Value: 1 - Yes, 0 - No, 99 - Not Applicable
Syntax Integer
Access Read-only

580 Storage Management Group


book.book Page 581 Monday, March 14, 2011 3:01 PM

Controller Persistent Hot Spare


Name controllerPersistentHotSpare
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.59
Description Indicates Persistent Hot Spare capability of the controller.
Value: 1 - Enabled, 0 - Disabled
Syntax Integer
Access Read-only

Controller Spin Down Unconfigured Drives


Name controllerSpinDownUnconfiguredDrives
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.60
Description Indicates controller capability to put unconfigured drives in
power save mode.
Value: 1 - Enabled, 0 - Disabled
Syntax Integer
Access Read-only

Controller Spin Down Hot Spare Drives


Name controllerSpinDownHotSpareDrives
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.61
Description Indicates controller capability to put hot spare drives in power
save mode.
Value: 1 - Enabled, 0 - Disabled
Syntax Integer
Access Read-only

Controller Spin Down Time Interval


Name controllerSpinDownTimeInterval
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.62

Storage Management Group 581


book.book Page 582 Monday, March 14, 2011 3:01 PM

Name controllerSpinDownTimeInterval
Description Shows the duration in minutes after which, the unconfigured or
hot spare drives is spun down to power save mode.
Value: 30 to 1440
NOTE: A value of 9999 indicates that the feature is not
available.
Syntax Integer
Access Read-write

Controller Encryption Mode


Name controllerEncryptionMode
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.63
Description Indicates the current encryption mode of the controller.
Value: 0 - No Encryption, 1 - Local Key Management (LKM),
2 - Dell Key Management (DKM), 99 - Not Applicable
Syntax Integer
Access Read-only

Controller CacheCade
Name controllerCacheCade
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.64
Description Indicates if the controller is CacheCade capable or not.
Value: 1 - Capable, 0 - Not Capable, 99 - Undetermined
Syntax Integer
Access Read-only

582 Storage Management Group


book.book Page 583 Monday, March 14, 2011 3:01 PM

Channel Table
This table describes available properties for each channel on the managed
system.
The following object sets up the Channel Table.

Name channelTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2
Description Defines the channel table.
Syntax SEQUENCE OF ChannelEntry
Access Not accessible

Channel Entry

Name channelEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1
Description Defines the channel table entry.
Syntax ChannelEntry
Access Not accessible
Index: channelNumber

Channel Number

Name channelNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.1
Description Identifies the instance number of the channel entry.
Syntax Integer
Access Read-only

Channel Name

Name channelName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.2

Storage Management Group 583


book.book Page 584 Monday, March 14, 2011 3:01 PM

Name channelName
Description Identifies the name of the channel as represented in Storage
Management. The name includes the word channel and the
instance. For example: Channel 1.
Syntax DisplayString
Access Read-only

Channel State

Name channelState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.3
Description Identifies the current state of this channel. Possible states:
0: Unknown
1: Ready - The I/O has resumed.
2: Failed
3: Online
4: Offline - The I/O has paused.
6: Degraded
Syntax Integer
Access Read-only

Channel Severity

Name channelSeverity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.4
Description This entry is obsolete for Storage Management. It was replaced
with RollUpStatus and ComponentStatus for each device.
Syntax Integer
Access Read-only

584 Storage Management Group


book.book Page 585 Monday, March 14, 2011 3:01 PM

Channel Termination

Name channelTermination
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.5
Description Identifies the type of SCSI termination on this channel.
Termination is required for proper operation of this channel.
Possible values:
1: Wide Termination (16 bit)
2: Narrow Termination (8 bit)
3: Not Terminated
Syntax Integer
Access Read-only

Channel SCSI ID

Name channelSCSIID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.6
Description Identifies the SCSI ID of the controller to which the channel
belongs.
Syntax Integer
Access Read-only

Storage Management Group 585


book.book Page 586 Monday, March 14, 2011 3:01 PM

Channel Roll-Up Status

Name channelRollUpStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.7
Description Identifies the severity of the channel state. This is the combined
status of the channel and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Channel Component Status

Name channelComponentStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.8
Description The status of the channel itself without the propagation of any
contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

586 Storage Management Group


book.book Page 587 Monday, March 14, 2011 3:01 PM

Channel Nexus ID

Name channelNexusID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.9
Description Durable unique ID for this channel.
Syntax DisplayString
Access Read-only

Channel Data Rate

Name channelDataRate
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.10
Description Identifies the data rate of this channel.
Syntax DisplayString
Access Read-only

Channel Bus Type

Name channelBusType
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.11
Description The bus type of the channel. Possible values:
1: SCSI
2: IDE
3: Fibre Channel
4: Serial Storage Architecture (SSA)
6: Universal Serial Bus (USB)
7: SATA
8: SAS
Syntax Integer
Access Read-only

Storage Management Group 587


book.book Page 588 Monday, March 14, 2011 3:01 PM

Enclosure Table
This table describes available properties for each enclosure on the managed
system.
The following object sets up the Enclosure Table.

Name enclosureTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3
Description Defines the enclosure table.
Syntax SEQUENCE OF EnclosureEntry
Access Not accessible

Enclosure Entry

Name enclosureEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1
Description Defines the enclosure table entry.
Syntax EnclosureEntry
Access Not accessible
Index enclosureNumber

Enclosure Number

Name enclosureNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.1
Description Identifies the instance number of the enclosure entry.
Syntax Integer
Access Read-only

588 Storage Management Group


book.book Page 589 Monday, March 14, 2011 3:01 PM

Enclosure Name

Name enclosureName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.2
Description Identifies the enclosure's name as represented in Storage
Management.
Syntax DisplayString
Access Read-only

Enclosure Vendor

Name enclosureVendor
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.3
Description Identifies the enclosure's (re)seller's name.
Syntax DisplayString
Access Read-only

Enclosure State

Name enclosureState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.4
Description The current condition of the enclosure (which includes any devices
connected to it.) Possible values:
0: Unknown
1: Ready
2: Failed
3: Online
4: Offline
6: Degraded
Syntax Integer
Access Read-only

Storage Management Group 589


book.book Page 590 Monday, March 14, 2011 3:01 PM

Enclosure Severity

Name enclosureSeverity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.5
Description This entry is obsolete for Storage Management. It was replaced
with RollUpStatus and ComponentStatus for each device.
Syntax Integer
Access Read-only

Enclosure ID

Name enclosureID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.6
Description Identifies the SCSI address of the processor.
Syntax Integer
Access Read-only

Enclosure Processor Version

Name enclosureProcessorVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.7
Description This entry is obsolete for Storage Management.
Syntax DisplayString
Access Read-only

Enclosure Service Tag

Name enclosureServiceTag
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.8
Description The enclosure identification used when consulting customer
support.
Syntax DisplayString
Access Read-only

590 Storage Management Group


book.book Page 591 Monday, March 14, 2011 3:01 PM

Enclosure Asset Tag

Name enclosureAssetTag
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.9
Description Customer definable asset tag for the enclosure.
Syntax DisplayString
Access Read-only

Enclosure Asset Name

Name enclosureAssetName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.10
Description Customer definable asset name of the enclosure.
Syntax DisplayString
Access Read-only

Enclosure Split Bus Part Number

Name enclosureSplitBusPartNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.11
Description Identifies the enclosure's split bus part number.
Syntax DisplayString
Access Read-only

Enclosure Product ID

Name enclosureProductID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.12
Description Identifies the enclosure's product identification. This also
corresponds to the enclosure type.
Syntax DisplayString
Access Read-only

Storage Management Group 591


book.book Page 592 Monday, March 14, 2011 3:01 PM

Enclosure Kernel Version

Name enclosureKernelVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.13
Description This entry is obsolete for Storage Management.
Syntax DisplayString
Access Read-only

Enclosure ESM1 Part Number

Name enclosureESM1PartNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.14
Description This entry is obsolete for Storage Management.
Syntax DisplayString
Access Read-only

Enclosure ESM2 Part Number

Name enclosureESM2PartNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.15
Description This entry is obsolete for Storage Management.
Syntax DisplayString
Access Read-only

592 Storage Management Group


book.book Page 593 Monday, March 14, 2011 3:01 PM

Enclosure Type

Name enclosureType
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.16
Description Indicates the type of the enclosure. Possible values:
1: Internal
2: Dell PowerVault 200S (PowerVault 201S)
3: Dell PowerVault 210S (PowerVault 211S)
4: Dell PowerVault 220S (PowerVault 221S)
5: Dell PowerVault 660F
6: Dell PowerVault 224F
7: Dell PowerVault 660F/PowerVault 224F
8: Dell MD1000
9: Dell MD1120
Syntax DisplayString
Access Read-only

Enclosure Processor2 Version

Name enclosureProcessor2Version
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.17
Description This entry is obsolete for Storage Management.
Syntax DisplayString
Access Read-only

Storage Management Group 593


book.book Page 594 Monday, March 14, 2011 3:01 PM

Enclosure Configuration

Name enclosureConfig
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.18
Description Identifies the current configuration of the enclosure's backplane.
Possible values:
1: Joined
2: Split Bus
3: Clustered
4: Unified
Syntax Integer
Access Read-only

Enclosure Channel Number

Name enclosureChannelNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.19
Description Identifies the channel number, or bus, to which the enclosure is
connected.
Syntax Integer
Access Read-only

Enclosure Alarm

Name enclosureAlarm
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.20
Description Identifies the current status of the enclosure's alarm (PowerVault
220S and PowerVault 221S only.) Possible values:
1: Disabled
2: Enabled
Syntax Integer
Access Read-only

594 Storage Management Group


book.book Page 595 Monday, March 14, 2011 3:01 PM

Enclosure Backplane Part Number

Name enclosureBackplanePartNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.21
Description Identifies the part number of the enclosure's backplane.
Syntax Integer
Access Read-only

Enclosure SCSI ID

Name enclosureSCSIID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.22
Description Identifies the SCSI ID of the controller to which this enclosure is
attached.
Syntax Integer
Access Read-only

Enclosure Roll-Up Status

Name enclosureRollUpStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.23
Description Identifies the severity of the enclosure state. This is the combined
status of the enclosure and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Storage Management Group 595


book.book Page 596 Monday, March 14, 2011 3:01 PM

Enclosure Component Status

Name enclosureComponentStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.24
Description The status of the enclosure itself without the propagation of any
contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Enclosure Nexus ID

Name enclosureNexusID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.25
Description Durable unique ID for this enclosure.
Syntax Integer
Access Read-only

Enclosure FirmWare Version

Name enclosureFirmwareVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.26
Description The firmware version of the enclosure.
Syntax DisplayString
Access Read-only

596 Storage Management Group


book.book Page 597 Monday, March 14, 2011 3:01 PM

Enclosure SCSI Rate

Name enclosureSCSIRate
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.27
Description Actual SCSI rate in the enclosure.
Syntax DisplayString
Access Read-only

Enclosure Part Number

Name enclosurePartNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.28
Description The part number of the enclosure.
Syntax DisplayString
Access Read-only

Enclosure Serial Number

Name enclosureSerialNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.29
Description Serial number of the enclosure.
Syntax DisplayString
Access Read-only

Enclosure SAS Address

Name enclosureSASAddress
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.30
Description The specified SAS address if this is a SAS enclosure.
Syntax DisplayString
Access Read-only

Storage Management Group 597


book.book Page 598 Monday, March 14, 2011 3:01 PM

Enclosure Occupied Slot Count

Name enclosureOccupiedSlotCount
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.31
Description Shows the number of physical disk slots occupied in a storage
enclosure.
NOTE: A value of 9999 indicates that the feature is not available.
Syntax Integer
Access Read-only

Enclosure Total Slots

Name enclosureTotalSlots
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.32
Description Shows the total number of physical slots in a storage enclosure; it
includes total count of occupied and empty slots.
NOTE: A value of 9999 indicates that the feature is not available.
Syntax Integer
Access Read-only

Enclosure Empty Slot Count

Name enclosureEmptySlotCount
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.33
Description Shows the number of empty physical disk slots in a storage
enclosure.
NOTE: A value of 9999 indicates that the feature is not available
Syntax Integer
Access Read-only

598 Storage Management Group


book.book Page 599 Monday, March 14, 2011 3:01 PM

Array Disk Table


This table describes available properties for each physical array disk on the
managed system.
The following object sets up the Array Disk Table.

Name arrayDiskTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4
Description Defines the array disk table.
Syntax SEQUENCE OF ArrayDiskEntry
Access Not accessible

Array Disk Entry

Name arrayDiskEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1
Description Defines the array disk table entry.
Syntax ArrayDiskEntry
Access Not accessible
Index arrayDiskNumber

Array Disk Number

Name arrayDiskNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.1
Description Identifies the instance number of the array disk entry.
Syntax Integer
Access Read-only

Storage Management Group 599


book.book Page 600 Monday, March 14, 2011 3:01 PM

Array Disk Name

Name arrayDiskName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2
Description Identifies the name of the array disk as represented in Storage
Management.
Syntax DisplayString
Access Read-only

Array Disk Vendor

Name arrayDiskVendor
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.3
Description The array disk's manufacturer's name.
Syntax DisplayString
Access Read-only

600 Storage Management Group


book.book Page 601 Monday, March 14, 2011 3:01 PM

Array Disk State

Name arrayDiskState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.4
Description Identifies the current state of the array disk. Possible states:
0: Unknown
1: Ready - Available for use, but no RAID configuration has been
assigned.
2: Failed - Not operational.
3: Online - Operational. RAID configuration has been assigned.
4: Offline - The drive is not available to the RAID controller.
6: Degraded - Refers to a fault-tolerant array/virtual disk that has a
failed disk.
7: Recovering - Refers to state of recovering from bad blocks on
disks.
11: Removed - Indicates that array disk has been removed.
15: Resynching - Indicates one of the following types of disk
operations: Transform Type, Reconfiguration, and Check
Consistency.
24: Rebuild
25: No Media - CD-ROM or removable disk has no media.
26: Formatting - In the process of formatting.
28: Diagnostics - Diagnostics are running.
34: Predictive Failure
35: Initializing: Applies only to virtual disks on PERC, PERC
2/SC, and PERC 2/DC controllers.
39: Foreign
40: Clear
41: Unsupported
53: Incompatible
Syntax Integer
Access Read-only

Storage Management Group 601


book.book Page 602 Monday, March 14, 2011 3:01 PM

Array Disk Severity

Name arrayDiskSeverity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.5
Description This entry is obsolete for Storage Management. It was replaced
with RollUpStatus and ComponentStatus for each device.
Syntax Integer
Access Read-only

Array Disk Product ID

Name arrayDiskProductID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.6
Description Identifies the model number of the array disk.
Syntax DisplayString
Access Read-only

Array Disk Serial Number

Name arrayDiskSerialNo
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.7
Description Identifies the array disk's unique identification number from the
manufacturer.
Syntax DisplayString
Access Read-only

Array Disk Revision

Name arrayDiskRevision
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.8
Description Identifies the firmware version of the array disk.
Syntax DisplayString
Access Read-only

602 Storage Management Group


book.book Page 603 Monday, March 14, 2011 3:01 PM

Array Disk Enclosure ID

Name arrayDiskEnclosureID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9
Description Identifies the SCSI ID of the enclosure processor to which this
array disk belongs.
Syntax DisplayString
Access Read-only

Array Disk Channel

Name arrayDiskChannel
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.10
Description Identifies the bus to which this array disk is connected.
Syntax Integer
Access Read-only

Array Disk Length in Megabytes

Name arrayDiskLengthInMB
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.11
Description Identifies the size in megabytes of the array disk. If this size is 0, it
is smaller than a megabyte.
Syntax Integer
Access Read-only

Array Disk Length in Bytes

Name arrayDiskLengthInBytes
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.12
Description Identifies the size of the array disk in bytes that is less than a
megabyte. This size plus the arrayDiskLengthInMB is the total
size of the array disk.
Syntax Integer
Access Read-only

Storage Management Group 603


book.book Page 604 Monday, March 14, 2011 3:01 PM

Array Disk Largest Contiguous Free Space in Megabytes

Name arrayDiskLargestContiguousFreeSpaceInMB
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.13
Description The size in megabytes of the largest contiguous free space on the
array disk. If this size is 0, it is less than a megabyte.
Syntax Integer
Access Read-only

Array Disk Largest Contiguous Free Space in Bytes

Name arrayDiskLargestContiguousFreeSpaceInBytes
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.14
Description The size of the largest contiguous free space on this array disk in
bytes that is less than a megabyte.This size plus the
arrayDiskLargestContiguousFreeSpaceInMB is the total size of
the largest contiguous free space on the array disk.
Syntax Integer
Access Read-only

Array Disk Target ID

Name arrayDiskTargetID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.15
Description Identifies the SCSI target ID which this array disk is assigned.
Syntax Integer
Access Read-only

Array Disk LUN ID

Name arrayDiskLunID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.16
Description Identifies the array disk's logical unit number.
Syntax Integer
Access Read-only

604 Storage Management Group


book.book Page 605 Monday, March 14, 2011 3:01 PM

Array Disk Used Space in Megabytes

Name arrayDiskUsedSpaceInMB
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.17
Description Identifies the amount in megabytes of the used space on the array
disk. If this size is 0, it is smaller than a megabyte.
Syntax Integer
Access Read-only

Array Disk Used Space in Bytes

Name arrayDiskUsedSpaceInBytes
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.18
Description Identifies the size in bytes of the used space on the array disk that
is smaller than a megabyte. This size plus the
arrayDiskUsedSpaceInMB is the total amount of used space on
the array disk.
Syntax Integer
Access Read-only

Array Disk Free Space in Megabytes

Name arrayDiskFreeSpaceInMB
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.19
Description Identifies the amount in megabytes of the free space on the array
disk. If this size is 0, it is smaller than a megabyte.
Syntax Integer
Access Read-only

Storage Management Group 605


book.book Page 606 Monday, March 14, 2011 3:01 PM

Array Disk Free Space in Bytes

Name arrayDiskFreeSpaceInBytes
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.20
Description Identifies the size in bytes of the free space on the array disk that is
smaller than a megabyte. This size plus the
arrayDiskFreeSpaceInMB is the total amount of free space on the
array disk.
Syntax Integer
Access Read-only

Array Disk Bus Type

Name arrayDiskBusType
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.21
Description Identifies the bus type of the array disk. Possible values:
1: SCSI
2: IDE
3: Fibre Channel
4: SSA
6: USB
7: SATA
8: SAS
Syntax Integer
Access Read-only

606 Storage Management Group


book.book Page 607 Monday, March 14, 2011 3:01 PM

Array Disk Spare State

Name arrayDiskSpareState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22
Description Identifies the status of the array disk as a spare. Possible states:
1: Disk is a member of a virtual disk
2: Disk is a member of a disk group
3: Disk is a global hot spare
4: Disk is a dedicated hot spare
5: Not a spare
99: Not applicable
Syntax Integer
Access Read-only

Array Disk Roll-Up Status

Name arrayDiskRollUpStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.23
Description Severity of the array disk state. This is the combined status of the
array disk and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Storage Management Group 607


book.book Page 608 Monday, March 14, 2011 3:01 PM

Array Disk Component Status

Name arrayDiskComponentStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.24
Description The status of the array disk itself without the propagation of any
contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Array Disk Device Name

Name arrayDiskDeviceName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.25
Description Identifies the operating system device name for this disk.
Syntax DisplayString
Access Read-only

Array Disk Nexus ID

Name arrayDiskNexusID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.26
Description Indicates the durable unique ID for this array disk.
Syntax DisplayString
Access Read-only

608 Storage Management Group


book.book Page 609 Monday, March 14, 2011 3:01 PM

Array Disk Part Number

Name arrayDiskPartNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.27
Description Indicates the part number of the disk.
Syntax DisplayString
Access Read-only

Array Disk SAS Address

Name arrayDiskSASAddress
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.28
Description Indicates the specified SAS address if this is a SAS disk.
Syntax DisplayString
Access Read-only

Array Disk Negotiated Speed

Name arrayDiskNegotiatedSpeed
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.29
Description Indicates the speed at which the drive is actually running in MPS
(megabytes per second).
Syntax Integer
Access Read-only

Array Disk Capable Speed

Name arrayDiskCapableSpeed
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.30
Description Indicates the maximum speed at which the drive is capable of
negotiating in MPS (megabytes per second).
Syntax Integer
Access Read-only

Storage Management Group 609


book.book Page 610 Monday, March 14, 2011 3:01 PM

Array Disk Smart Alert Indication

Name arrayDiskSmartAlertIndication
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.31
Description Indicates whether the disk has received a predictive failure.
Possible values:
1: No - disk has not received a predictive failure alert
2: Yes - disk has received a predictive failure alert
Syntax Integer
Access Read-only

Array Disk Manufacture Day

Name arrayDiskManufactureDay
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.32
Description Indicates the day of the week (1=Sunday through 7=Saturday) on
which this disk was manufactured.
Syntax DisplayString
Access Read-only

Array Disk Manufacture Week

Name arrayDiskManufactureWeek
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.33
Description Indicates the week (1 through 53) in which this disk was
manufactured.
Syntax DisplayString
Access Read-only

610 Storage Management Group


book.book Page 611 Monday, March 14, 2011 3:01 PM

Array Disk Manufacture Year

Name arrayDiskManufactureYear
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.34
Description Indicates the four digit year in which this disk was manufactured.
Syntax DisplayString
Access Read-only

Array Disk Media Type


Name arrayDiskMediaType
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.35
Description Indicates the media type of the array disk.
Syntax INTEGER
Access Read-only

Array Disk Dell Certified


Name arrayDiskDellCertified
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.36
Description Indicates if array disk is certified by Dell.
Value: 1 - Certified, 0 - Not Certified, 99 - Unknown
Syntax Integer
Access Read-only

Array Disk Alta Vendor Id


Name arrayDiskAltaVendorId
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.37
Description Provides vendor information for Alta interposer.
Syntax Octet String
Access Read-only

Storage Management Group 611


book.book Page 612 Monday, March 14, 2011 3:01 PM

Array Disk Alta Product Id


Name arrayDiskAltaProductId
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.38
Description Provides product ID for Alta interposer.
Syntax Octet String
Access Read-only

Array Disk Alta Revision Id


Name arrayDiskAltaRevisionId
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.39
Description Provides revision ID for Alta interposer.
Syntax Octet String
Access Read-only

Array Disk Encryption Capable


Name arrayDiskEncryptionCapable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.40
Description Indicates if physical disk is encryption capable.
Value: 1 - Capable, 0 - Not Capable, 99 - Not Applicable
Syntax Integer
Access Read-only

Array Disk Encrypted


Name arrayDiskEncrypted
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.41
Description Indicates if the physical disk has encryption enabled.
Value: 1 - Yes, 0 - No, 99 - Not Applicable
Syntax Integer
Access Read-only

612 Storage Management Group


book.book Page 613 Monday, March 14, 2011 3:01 PM

Array Disk Power State


Name arrayDiskPowerState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.42
Description Indicates power state of a physical drive.
Value: 0 - Spun up, 1- Spun down, 255 - Transition
Syntax Integer
Access Read-only

Array Disk Enclosure Connection Table


This table describes the connections among array disks, their enclosure, and
their associated controller. For each object in the table, its object number
corresponds to an instance number in the appropriate MIB table for that
object where all of the object properties can be found.
NOTE: Only array disks that are part of an enclosure are listed in this table.
Backplanes are considered enclosures by Storage Management.
The following object sets up the Array Disk Enclosure Connection Table.

Name arrayDiskEnclosureConnectionTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.5
Description Defines the array disk enclosure connection table.
Syntax SEQUENCE OF ArrayDiskEnclosureConnectionEntry
Access Not accessible

Array Disk Enclosure Connection Entry

Name arrayDiskEnclosureConnectionEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1
Description Defines the array disk enclosure connection table entry.
Syntax ArrayDiskEnclosureConnectionEntry
Access Not accessible
Index arrayDiskEnclosureConnectionNumber

Storage Management Group 613


book.book Page 614 Monday, March 14, 2011 3:01 PM

Array Disk Enclosure Connection Number

Name arrayDiskEnclosureConnectionNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.1
Description Identifies the instance number of the array disk enclosure
connection entry.
Syntax Integer
Access Read-only

Array Disk Enclosure Connection Array Disk Name

Name arrayDiskEnclosureConnectionArrayDiskName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.2
Description Identifies the name of the array disk in this connection as
represented in Storage Management.
Syntax DisplayString
Access Read-only

Array Disk Enclosure Connection Array Disk Number


Name arrayDiskEnclosureConnectionArrayDiskNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.3
Description Identifies the instance number of the array disk in the
arrayDiskTable in this connection.
Syntax Integer
Access Read-only

Array Disk Enclosure Connection Enclosure Name

Name arrayDiskEnclosureConnectionEnclosureName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.4
Description Identifies the name of the enclosure as represented in Storage
Management to which this array disk belongs.
Syntax DisplayString
Access Read-only

614 Storage Management Group


book.book Page 615 Monday, March 14, 2011 3:01 PM

Array Disk Enclosure Connection Enclosure Number

Name arrayDiskEnclosureConnectionEnclosureNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.5
Description Identifies the instance number in the enclosureTable of the
enclosure to which this array disk belongs.
Syntax Integer
Access Read-only

Array Disk Enclosure Connection Controller Name

Name arrayDiskEnclosureConnectionControllerName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.6
Description Identifies the name of the controller as represented in Storage
Management to which this array disk is connected.
Syntax DisplayString
Access Read-only

Array Disk Enclosure Connection Controller Number

Name arrayDiskEnclosureConnectionControllerNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.7
Description Identifies the instance number in the controllerTable of the
controller to which this array disk is connected.
Syntax Integer
Access Read-only

Array Disk Channel Connection Table


This table describes the connections between array disks, their channel, and
their associated controller. For each object in the table, its object number
corresponds to an instance number in the appropriate MIB table for that
object where all of the object properties can be found.
NOTE: Only array disks that are NOT part of an enclosure are listed in this table.
Backplanes are considered enclosures by Storage Management.

Storage Management Group 615


book.book Page 616 Monday, March 14, 2011 3:01 PM

The following object sets up the Array Disk Channel Connection Table.

Name arrayDiskChannelConnectionTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.6
Description Defines the array disk channel connection table.
Syntax SEQUENCE OF ArrayDiskChannelConnectionEntry
Access Not accessible

Array Disk Channel Connection Entry

Name arrayDiskChannelConnectionEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1
Description Defines the array disk channel connection table entry.
Syntax ArrayDiskChannelConnectionEntry
Access Not accessible
Index arrayDiskEnclosureConnectionNumber

Array Disk Channel Connection Number

Name arrayDiskChannelConnectionNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.1
Description Identifies the instance number of the array disk channel
connection entry.
Syntax Integer
Access Read-only

Array Disk Channel Connection Array Disk Name

Name arrayDiskChannelConnectionArrayDiskName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.2
Description Identifies the name of the array disk in this connection as
represented in Storage Management.
Syntax DisplayString
Access Read-only

616 Storage Management Group


book.book Page 617 Monday, March 14, 2011 3:01 PM

Array Disk Channel Connection Array Disk Number

Name arrayDiskChannelConnectionArrayDiskNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.3
Description Identifies the instance number of the array disk in the
arrayDiskTable in this connection.
Syntax Integer
Access Read-only

Array Disk Channel Connection Channel Name

Name arrayDiskChannelConnectionChannelName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.4
Description Identifies the name of the channel as represented in Storage
Management to which is array disk is connected.
Syntax DisplayString
Access Read-only

Array Disk Channel Connection Channel Number

Name arrayDiskChannelConnectionChannelNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.5
Description Identifies the instance number of the channel in the channelTable
to which this array disk is connected.
Syntax Integer
Access Read-only

Array Disk Channel Connection Controller Name

Name arrayDiskChannelConnectionControllerName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.6
Description Identifies the name of the controller as represented in Storage
Management to which this array disk is connected.
Syntax DisplayString
Access Read-only

Storage Management Group 617


book.book Page 618 Monday, March 14, 2011 3:01 PM

Array Disk Channel Connection Controller Number

Name arrayDiskChannelConnectionControllerNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.7
Description Identifies the instance number in the controllerTable of the
controller to which this array disk is connected.
Syntax Integer
Access Read-only

Fan Table
This table describes available properties for each fan on the managed system.
The following object sets up the Fan Table.
Name fanTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7
Description Defines the fan table.
Syntax SEQUENCE OF FanEntry
Access Not accessible

Fan Entry

Name fanEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1
Description Defines the fan table entry.
Syntax FanEntry
Access Not accessible
Index fanNumber

618 Storage Management Group


book.book Page 619 Monday, March 14, 2011 3:01 PM

Fan Number
Name fanNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.1
Description Identifies the instance number of the fan entry.
Syntax Integer
Access Read-only

Fan Name

Name Fan Name


Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.2
Description Identifies the fan's name as represented in Storage Management.
Syntax DisplayString
Access Read-only

Fan Vendor

Name fanVendor
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.3
Description Identifies the fan's (re)seller's name.
Syntax DisplayString
Access Read-only

Storage Management Group 619


book.book Page 620 Monday, March 14, 2011 3:01 PM

Fan State

Name fanState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.4
Description Identifies the current state of the fan. Possible states:
0: Unknown
1: Ready
2: Failed
3: Online
4: Offline
6: Degraded
21: Missing
Syntax Integer
Access Read-only

Fan Severity

Name fanSeverity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.5
Description This entry is obsolete for Storage Management. It was replaced
with RollUpStatus and ComponentStatus for each device.
Syntax Integer
Access Read-only

Fan Probe Unit

Name fanProbeUnit
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.6
Description This entry is obsolete for Storage Services.
Syntax DisplayString
Access Read-only

620 Storage Management Group


book.book Page 621 Monday, March 14, 2011 3:01 PM

Fan Probe Minimum Warning

Name fanProbeMinimumWarning
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.7
Description This entry is obsolete. This setting is not supported by fans
managed under Storage Management.
Syntax DisplayString
Access Read-only

Fan Probe Minimum Critical

Name fanProbeMinimumCritical
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.8
Description This entry is obsolete. This setting is not supported by fans
managed under Storage Management.
Syntax DisplayString
Access Read-only

Fan Probe Maximum Warning

Name fanProbeMaximumWarning
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.9
Description This entry is obsolete. This setting is not supported by fans
managed under Storage Management.
Syntax DisplayString
Access Read-only

Fan Probe Maximum Critical

Name fanProbeMaximumCritical
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.10
Description This entry is obsolete. This setting is not supported by fans
managed under Storage Management.
Syntax DisplayString
Access Read-only

Storage Management Group 621


book.book Page 622 Monday, March 14, 2011 3:01 PM

Fan Probe Current Value

Name fanProbeCurrValue
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.11
Description Identifies the current speed of the fan.
Syntax DisplayString
Access Read-only

Fan1 Part Number

Name fan1PartNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.12
Description Identifies the part number of the fan in the enclosure.
Syntax DisplayString
Access Read-only

Fan 2 Part Number

Name fan2PartNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.13
Description This entry is obsolete. This setting is not supported by fans
managed under Storage Management.
Syntax DisplayString
Access Read-only

622 Storage Management Group


book.book Page 623 Monday, March 14, 2011 3:01 PM

Fan Roll-Up Status

Name fanRollUpStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.14
Description Severity of the fan state. This is the combined status of the fan
and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Fan Component Status

Name fanComponentStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.15
Description The status of the fan itself without the propagation of any
contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Storage Management Group 623


book.book Page 624 Monday, March 14, 2011 3:01 PM

Fan Nexus ID

Name fanNexusID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.16
Description Durable unique ID for this fan.
Syntax DisplayString
Access Read-only

Fan Revision

Name fanRevision
Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.17
Description Indicates the revision number of the fan in the enclosure.
Syntax DisplayString
Access Read-only

Fan Connection Table


This table describes the connection between each fan on the managed system
and its enclosure. Each enclosure number in the table corresponds to that
enclosure instance in the enclosure Table.
The following object sets up the Fan Connection Table.

Name fanConnectionTable
Object ID fanConnectionTable
Description Defines the fan connection table.
Syntax SEQUENCE OF FanConnectionEntry
Access Not accessible

Fan Connection Entry

Name fanConnectionEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1
Description Defines the fan connection table entry.

624 Storage Management Group


book.book Page 625 Monday, March 14, 2011 3:01 PM

Name fanConnectionEntry
Syntax FanConnectionEntry
Access Not accessible
Index fanConnectionNumber

Fan Connection Number

Name fanConnectionNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.1
Description Identifies the instance number of the fan connection entry.
Syntax Integer
Access Read-only

Fan Connection Fan Name

Name fanConnectionFanName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.2
Description Identifies the name of the fan in this connection as represented in
Storage Management.
Syntax DisplayString
Access Read-only

Fan Connection Fan Number

Name fanConnectionFanNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.3
Description Identifies the instance number of the fan in the fanTable in the
connection.
Syntax Integer
Access Read-only

Storage Management Group 625


book.book Page 626 Monday, March 14, 2011 3:01 PM

Fan Connection Enclosure Name

Name fanConnectionEnclosureName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.4
Description Identifies the name of the enclosure as represented in Storage
Management to which this fan belongs.
Syntax DisplayString
Access Read-only

Fan Connection Enclosure Number

Name fanConnectionEnclosureNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.5
Description Identifies the instance number of the enclosure in the
enclosureTable to which this fan belongs.
Syntax Integer
Access Read-only

Power Supply Table


This table describes available properties for each power supply on the
managed system.
The following object sets up the Power Supply Table.

Name powerSupplyTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9
Description Defines the power supply table.
Syntax SEQUENCE OF PowerSupplyEntry
Access Not accessible

626 Storage Management Group


book.book Page 627 Monday, March 14, 2011 3:01 PM

Power Supply Entry

Name powerSupplyEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1
Description Defines the power supply table entry.
Syntax PowerSupplyEntry
Access Not accessible
Index powerSupplyNumber

Power Supply Number

Name powerSupplyNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.1
Description Identifies the instance number of the power supply entry.
Syntax Integer
Access Read-only

Power Supply Name

Name powerSupplyName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.2
Description Identifies the power supply's name as represented in Storage
Management.
Syntax DisplayString
Access Read-only

Power Supply Vendor

Name powerSupplyVendor
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.3
Description Identifies the power supply's (re)seller's name.
Syntax DisplayString
Access Read-only

Storage Management Group 627


book.book Page 628 Monday, March 14, 2011 3:01 PM

Power Supply State

Name powerSupplyState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.4
Description Identifies the current state of the power supply. Possible states:
0: Unknown
1: Ready
2: Failed
5: Not Installed
6: Degraded
11: Removed
Syntax Integer
Access Read-only

Power Supply Severity

Name powerSupplySeverity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.5
Description This entry is obsolete for Storage Management. It was replaced
with RollUpStatus and ComponentStatus for each device.
Syntax Integer
Access Read-only

Power Supply 1 Part Number

Name powerSupply1PartNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.6
Description Identifies the part number of the power supply of the enclosure.
Syntax DisplayString
Access Read-only

628 Storage Management Group


book.book Page 629 Monday, March 14, 2011 3:01 PM

Power Supply 2 Part Number

Name powerSupply2PartNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.7
Description This entry is obsolete. This setting is not supported by power
supplies managed under Storage Management
Syntax DisplayString
Access Read-only

Power Supply Roll-Up Status

Name powerSupplyRollUpStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.8
Description Severity of the power supply state. This is the combined status of
the power supply and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Storage Management Group 629


book.book Page 630 Monday, March 14, 2011 3:01 PM

Power Supply Component Status

Name powerSupplyComponentStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.9
Description Severity of the power supply state. This is the combined status of
the power supply and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Power Supply NexusID

Name powerSupplyNexusID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.10
Description Durable unique ID for this power supply.
Syntax DisplayString
Access Read-only

Power Supply Revision

Name powerSupplyRevision
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.11
Description Indicates the revision number of the power supply in the
enclosure.
Syntax DisplayString
Access Read-only

630 Storage Management Group


book.book Page 631 Monday, March 14, 2011 3:01 PM

Power Supply Connection Table


This table describes the connection between each power supply on the
managed system and its enclosure. Each enclosure number in the table
corresponds to that enclosure instance in the enclosure Table.
The following object sets up the Power Supply Connection Table.

Name powerSupplyConnectionTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.10
Description Defines the power supply connection table.
Syntax SEQUENCE OF PowerSupplyConnectionEntry
Access Not accessible

Power Supply Connection Entry

Name powerSupplyConnectionEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1
Description Defines the power supply connection table entry.
Syntax PowerSupplyConnectionEntry
Access Not accessible
Index powerSupplyConnectionNumber

Power Supply Connection Number

Name powerSupplyConnectionNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.1
Description Identifies the instance number of the power supply connection
entry.
Syntax Integer
Access Read-only

Storage Management Group 631


book.book Page 632 Monday, March 14, 2011 3:01 PM

Power Supply Connection Power Supply Name

Name powerSupplyConnectionPowerSupplyName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.2
Description Identifies the name of the power supply in this connection as
represented in Storage Management.
Syntax DisplayString
Access Read-only

Power Supply Connection Power Supply Number

Name powerSupplyConnectionPowerSupplyNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.3
Description Identifies the instance number of the power supply in the
powerSupplyTable in the connection.
Syntax Integer
Access Read-only

Power Supply Connection Enclosure Name

Name powerSupplyConnectionEnclosureName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.4
Description Identifies the name of the enclosure as represented in Storage
Management to which this power supply belongs.
Syntax DisplayString
Access Read-only

Power Supply Connection Enclosure Number

Name powerSupplyConnectionEnclosureNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.5
Description Identifies the instance number of the enclosure in the
enclosureTable to which this power supply belongs.
Syntax Integer
Access Read-only

632 Storage Management Group


book.book Page 633 Monday, March 14, 2011 3:01 PM

Temperature Probe Table


This table describes available properties for each temperature probe on the
managed system.
The following object sets up the Temperature Probe Table.

Name temperatureProbeTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11
Description A table of managed temperature probes. The number of entries is
related to the number of temperature probes discovered in the
system. The maximum number of entries is implementation
dependent.
NOTE: The properties in this table may not be applicable to all entries.
Syntax SEQUENCE OF TemperatureProbeEntry
Access Not accessible

Temperature Probe Entry

Name temperatureProbeEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1
Description An entry in the Temperature Probe Table. A row in this table
cannot be created or deleted by SNMP operations on columns of
the table.
Syntax TemperatureProbeEntry
Access Not accessible
Index TemperatureProbeNumber

Temperature Probe Number

Name temperatureProbeNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.1
Description Identifies the instance number of the temperature probe entry.
Syntax Integer
Access Read-only

Storage Management Group 633


book.book Page 634 Monday, March 14, 2011 3:01 PM

Temperature Probe Name

Name temperatureProbeName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.2
Description Identifies the temperature probe's name as represented in Storage
Management.
Syntax DisplayString
Access Read-only

Temperature Probe Vendor

Name temperatureProbeVendor
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.3
Description Identifies the temperature probe's (re)seller's name.
Syntax DisplayString
Access Read-only

Temperature Probe State

Name temperatureProbeState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.4
Description Identifies the current state of the temperature probe. Possible states:
0: Unknown
1: Ready
2: Failed (Minimum Failure Threshold Exceeded, Maximum Failure
Threshold Exceeded)
4: Offline
6: Degraded (Minimum Warning Threshold Exceeded, Maximum
Warning Threshold Exceeded)
9: Inactive
21: Missing
Syntax Integer
Access Read-only

634 Storage Management Group


book.book Page 635 Monday, March 14, 2011 3:01 PM

Temperature Probe Severity

Name temperatureProbeSeverity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.5
Description This entry is obsolete for Storage Management. It was replaced
with RollUpStatus and ComponentStatus for each device.
Syntax Integer
Access Read-only

Temperature Probe Unit

Name temperatureProbeUnit
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.6
Description The units that are used to display temperatures for the
temperature probe.
Syntax DisplayString
Access Read-only

Temperature Probe Minimum Warning

Name temperatureProbeMinWarning
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.7
Description Identifies the minimum temperature that forces the probe into a
warning state.
Syntax Integer
Access Read-only

Temperature Probe Minimum Critical

Name temperatureProbeMinCritical
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.8
Description Identifies the minimum temperature that forces the probe into an
error state.
Syntax Integer
Access Read-only

Storage Management Group 635


book.book Page 636 Monday, March 14, 2011 3:01 PM

Temperature Probe Maximum Warning

Name temperatureProbeMaxWarning
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.9
Description Identifies the maximum temperature that forces the probe into a
warning state.
Syntax Integer
Access Read-only

Temperature Probe Maximum Critical

Name temperatureProbeMaxCritical
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.10
Description Identifies the maximum temperature that forces the probe into an
error state.
Syntax Integer
Access Read-only

Temperature Probe Current Value

Name temperatureProbeCurValue
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.11
Description Identifies the current temperature of this probe.
Syntax Integer
Access Read-only

636 Storage Management Group


book.book Page 637 Monday, March 14, 2011 3:01 PM

Temperature Probe Roll-Up Status

Name temperatureProbeRollUpStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.12
Description Severity of the temperature probe state. This is the combined
status of the temperature probe and its components. Possible
values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Temperature Probe Component Status

Name temperatureProbeComponentStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.13
Description The status of the temperature probe itself without the
propagation of any contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Storage Management Group 637


book.book Page 638 Monday, March 14, 2011 3:01 PM

Temperature Probe Nexus ID

Name temperatureProbeNexusID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.14
Description Durable unique ID for this temperature probe.
Syntax DisplayString
Access Read-only

Temperature Probe Connection Table


This table describes the connection between each temperature probe on the
managed system and its enclosure. Each enclosure number in the table
corresponds to that enclosure instance in the enclosure Table.
The following object sets up the Temperature Probe Connection Table.

Name temperatureConnectionTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.12
Description Defines the temperature probe connection table.
Syntax SEQUENCE OF TemperatureConnectionEntry
Access Not accessible

Temperature Probe Connection Entry

Name temperatureConnectionEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1
Description Defines the temperature probe connection table entry.
Syntax TemperatureConnectionEntry
Access Not accessible
Index temperatureConnectionNumber

638 Storage Management Group


book.book Page 639 Monday, March 14, 2011 3:01 PM

Temperature Probe Connection Number

Name temperatureConnectionNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.1
Description Identifies the instance number of the temperature probe
connection entry.
Syntax Integer
Access Read-only

Temperature Probe Connection Temperature Probe Name

Name temperatureConnectionTemperatureName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.2
Description Identifies the name of the temperature probe in this connection as
represented in Storage Management.
Syntax DisplayString
Access Read-only

Temperature Probe Connection Temperature Probe Number

Name temperatureConnectionTemperatureNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.3
Description Identifies the instance number in the temperatureTable of the
temperature probe in this connection.
Syntax Integer
Access Read-only

Temperature Probe Connection Enclosure Name

Name temperatureConnectionEnclosureName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.4
Description Identifies the name of the enclosure as represented in Storage
Management to which this temperature probe belongs.
Syntax DisplayString
Access Read-only

Storage Management Group 639


book.book Page 640 Monday, March 14, 2011 3:01 PM

Temperature Probe Connection Enclosure Number

Name temperatureConnectionEnclosureNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.5
Description Identifies the instance number of the enclosure in the
enclosureTable to which this temperature probe belongs.
Syntax Integer
Access Read-only

Enclosure Management Module Table


This table describes available properties for each enclosure management
module on the managed system.
The following object sets up the Enclosure Management Module Table.

Name enclosureManagementModuleTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.13
Description Defines the enclosure management module table.
Syntax SEQUENCE OF EnclosureManagementModuleEntry
Access Not accessible

Enclosure Management Module Entry

Name EnclosureManagementModuleEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1
Description Defines the enclosure management module table entry.
Syntax EnclosureManagementModuleEntry
Access Not accessible
Index enclosureManagementModuleNumber

640 Storage Management Group


book.book Page 641 Monday, March 14, 2011 3:01 PM

Enclosure Management Module Number

Name enclosureManagementModuleNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.1
Description Identifies the instance number of the enclosure management
module entry.
Syntax Integer
Access Read-only

Enclosure Management Module Name

Name enclosureManagementModuleName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.2
Description Identifies the enclosure management module's name as
represented in Storage Management.
Syntax DisplayString
Access Read-only

Enclosure Management Module Vendor

Name enclosureManagementModuleVendor
Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.3
Description Identifies the enclosure management module's (re)seller's name.
Syntax DisplayString
Access Read-only

Storage Management Group 641


book.book Page 642 Monday, March 14, 2011 3:01 PM

Enclosure Management Module State

Name enclosureManagementModuleState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.4
Description Identifies the current state of the enclosure management module.
Possible states:
0: Unknown
1: Ready
2: Failed
3: Online
4: Offline
5: Not Installed
6: Degraded
21: Missing
Syntax Integer
Access Read-only

Enclosure Management Module Severity

Name enclosureManagementModuleSeverity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.5
Description This entry is obsolete for Storage Management. It was replaced
with RollUpStatus and ComponentStatus for each device.
Syntax Integer
Access Read-only

Enclosure Management Module Part Number

Name enclosureManagementModulePartNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.6
Description Identifies the part number of the enclosure memory module.
Syntax Display String
Access Read-only

642 Storage Management Group


book.book Page 643 Monday, March 14, 2011 3:01 PM

Enclosure Management Module Type

Name enclosureManagementModuleType
Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.7
Description Identifies the type of the enclosure management module. Possible
values:
0: Unknown
1: EMM
2: Termination Card
Syntax Integer
Access Read-only

Enclosure Management Module Firmware Version

Name enclosureManagementModuleFWVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.8
Description Identifies the firmware version of the enclosure memory module.
Syntax DisplayString
Access Read-only

Enclosure Management Module Maximum Speed

Name enclosureManagementModuleMaxSpeed
Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.9
Description Identifies the maximum bus speed of the enclosure management
module.
Syntax DisplayString
Access Read-only

Storage Management Group 643


book.book Page 644 Monday, March 14, 2011 3:01 PM

Enclosure Management Module Roll-Up Status

Name enclosureManagementModuleRollUpStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.10
Description Severity of the enclosure management module state. This is the
combined status of the EMM and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Enclosure Management Module Component Status

Name enclosureManagementModuleComponentStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.11
Description The status of the enclosure management module itself without
the propagation of any contained component status. Possible
values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

644 Storage Management Group


book.book Page 645 Monday, March 14, 2011 3:01 PM

Enclosure Management Module Nexus ID

Name enclosureManagementModuleNexusID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.12
Description Durable unique ID for this EMM.
Syntax DisplayString
Access Read-only

Enclosure Management Module Revision

Name enclosureManagementModuleRevision
Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.13
Description Identifies the revision number of the enclosure management
module.
Syntax DisplayString
Access Read-only

Enclosure Management Module Connection Table


This table describes the connection between each enclosure management
module on the managed system and its enclosure. Each enclosure number in
the table corresponds to that enclosure instance in the enclosure Table.
The following object sets up the Enclosure Management Module Connection
Table.

Name enclosureManagementModuleConnectionTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.14
Description Defines the enclosure memory module connection table.
Syntax SEQUENCE OF EnclosureManagementModuleConnectionEntry
Access Not accessible

Storage Management Group 645


book.book Page 646 Monday, March 14, 2011 3:01 PM

Enclosure Management Module Connection Entry

Name enclosureManagementModuleConnectionEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1
Description Defines the enclosure memory module connection table entry.
Syntax EnclosureManagementModuleConnectionEntry
Access Not accessible
Index enclosureManagementModuleConnectionNumber

Enclosure Management Module Connection Number

Name enclosureManagementModuleConnectionNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.1
Description Identifies the instance number of the enclosure memory module
connection entry.
Syntax Integer
Access Read-only

Enclosure Management Module Connection EMM Name

Name enclosureManagementModuleConnectionEMMName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.2
Description Identifies the name of the enclosure memory module in this
connection as represented in Storage Management.
Syntax DisplayString
Access Read-only

646 Storage Management Group


book.book Page 647 Monday, March 14, 2011 3:01 PM

Enclosure Management Module Connection EMM Number

Name enclosureManagementModuleConnectionEMMNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.3
Description Identifies the instance number in the
enclosureManagementModuleTable of the enclosure memory
module in this connection.
Syntax Integer
Access Read-only

Enclosure Management Module Connection Enclosure Name

Name enclosureManagementModuleConnectionEnclosureName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.4
Description Identifies the name of the enclosure as represented in Storage
Management to which this enclosure memory module belongs.
Syntax DisplayString
Access Read-only

Enclosure Management Module Connection Enclosure Number

Name enclosureManagementModuleConnectionEnclosure
Number
Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.5
Description Identifies the instance number of the enclosure in the
enclosureTable to which this enclosure memory module belongs.
Syntax Integer
Access Read-only

Storage Management Group 647


book.book Page 648 Monday, March 14, 2011 3:01 PM

Battery Table
This table describes available properties for each controller battery on the
managed system.
The following object sets up the Battery Table.

Name batteryTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15
Description Defines the battery table.
Syntax SEQUENCE OF BatteryEntry
Access Not accessible

Battery Entry

Name batteryEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1
Description Defines the battery table entry.
Syntax BatteryEntry
Access Not accessible
Index batteryNumber

Battery Number

Name batteryNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.1
Description Identifies the instance number of the battery entry.
Syntax Integer
Access Read-only

648 Storage Management Group


book.book Page 649 Monday, March 14, 2011 3:01 PM

Battery Name

Name batteryName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.2
Description Identifies the battery's name as represented in Storage
Management.
Syntax DisplayString
Access Read-only

Battery Vendor

Name batteryVendor
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.3
Description Identifies the battery's (re)seller's name.
Syntax DisplayString
Access Read-only

Battery State

Name batteryState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.4
Description Identifies the current state of battery. Possible values:
0: Unknown
1: OK
2: Failed
6: Degraded
7: Reconditioning
9: High
10: Low
12: Charging
21: Missing
36: Learning
Syntax Integer
Access Read-only

Storage Management Group 649


book.book Page 650 Monday, March 14, 2011 3:01 PM

Battery Roll-Up Status

Name batteryRollUpStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.5
Description Severity of the battery state. This is the combined status of the
battery and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Battery Component Status

Name batteryComponentStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.6
Description The status of the battery itself without the propagation of any
contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

650 Storage Management Group


book.book Page 651 Monday, March 14, 2011 3:01 PM

Battery Charge Count

Name batteryChargeCount
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.7
Description The number of charges that have been applied to the battery.
Syntax Integer
Access Read-only

Battery Max Charge Count

Name batteryMaxChargeCount
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.8
Description The maximum number of charges that can be applied to the
battery.
Syntax Integer
Access Read-only

Battery Nexus ID

Name batteryNexusID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.9
Description Durable unique ID for this EMM.
Syntax DisplayString
Access Read-only

Storage Management Group 651


book.book Page 652 Monday, March 14, 2011 3:01 PM

Battery Predicted Capacity

Name batteryPredictedCapacity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.10
Description Displays the battery's ability to be charged.
Possible values:
1: Failed - The battery cannot be charged and needs to be
replaced.
2: Ready - The battery can be charged to full capacity.
4: Unknown - The battery is completing a Learn cycle. The charge
capacity of the battery cannot be determined until the Learn cycle
is complete.
Syntax Integer
Access Read-only

Battery Next Learn Time

Name batteryNextLearnTime
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.11
Description Indicates the time (in hours) the next learn cycle must be
executed
Syntax Integer
Access Read-only

652 Storage Management Group


book.book Page 653 Monday, March 14, 2011 3:01 PM

Battery Learn State

Name batteryLearnState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.12
Description Specifies the learn state activity of the battery.
Possible values:
1: Failed
2: Active
4: Timed out
8: Requested
16: Idle
Syntax Integer
Access Read-only

Battery Maximum Learn Delay

Name batteryMaxLearnDelay
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.14
Description The maximum amount of time (in hours) that the battery learn
cycle can be delayed.
Syntax Integer
Access Read-only

Storage Management Group 653


book.book Page 654 Monday, March 14, 2011 3:01 PM

Battery Connection Table


This table describes the connection between each controller battery on the
managed system and its controller. Each controller number in the table
corresponds to that controller instance in the controller Table.
The following object sets up the Battery Connection Table.

Name batteryConnectionTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.16
Description Defines the battery connection table.
Syntax SEQUENCE OF BatteryConnectionEntry
Access Not accessible

Battery Connection Entry

Name batteryConnectionEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1
Description Defines the battery connection table entry.
Syntax BatteryConnectionEntry
Access BatteryConnectionEntry
Index BatteryConnectionNumber

Battery Connection Number

Name batteryConnectionNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.1
Description Identifies the instance number of the battery connection entry.
Syntax Integer
Access Read-only

654 Storage Management Group


book.book Page 655 Monday, March 14, 2011 3:01 PM

Battery Connection Battery Name

Name batteryConnectionBatteryName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.2
Description Identifies the name of the battery in this connection as
represented in Storage Management.
Syntax DisplayString
Access Read-only

Battery Connection Battery Number

Name batteryConnectionBatteryNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.3
Description Identifies the instance number in the batteryTable of the battery
in this connection.
Syntax Integer
Access Read-only

Battery Connection Controller Name

Name batteryConnectionControllerName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.4
Description Identifies the name of the controller as represented in Storage
Management to which this battery belongs.
Syntax DisplayString
Access Read-only

Battery Connection Controller Number

Name batteryConnectionControllerNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.5
Description Identifies instance number of the controller in the controllerTable
to which this battery belongs.
Syntax Integer
Access Read-only

Storage Management Group 655


book.book Page 656 Monday, March 14, 2011 3:01 PM

Logical Devices Group


The Logical Devices Management Information Base (MIB) group provides
information about the logical devices managed by the Dell Storage
Management Software and their relationships to each other.
This group and all of its associated tables and objects are not supported on
Microsoft Windows Advanced Server Limited Edition 64-bit operating
system (Windows.Net-64) on a Dell PowerEdge 7150. The following MIB
tables define objects and relationships, or connections among the objects, in
the Logical Devices Group:
• Virtual Disk Table—describes available properties for each virtual disk on
the managed system.
• Array Disk Logical Connection Table—describes the connections
between array disks, the virtual disk to which they belong, and their
associated logical disk. For each object in the table, its object number
corresponds to an instance number in the appropriate MIB table for that
object where all of the object properties can be found.

Virtual Disk Table


This table describes available properties for each virtual disk on the managed
system.
The following object sets up the Virtual Disk Table.

Name virtualDiskTable
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1
Description Defines the virtual disk table.
Syntax SEQUENCE OF VirtualDiskEntry
Access Not accessible

656 Storage Management Group


book.book Page 657 Monday, March 14, 2011 3:01 PM

Virtual Disk Entry

Name virtualDiskEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1
Description Defines the virtual disk table entry.
Syntax VirtualDiskEntry
Access Not accessible
Index virtualDiskNumber

Virtual Disk Number

Name virtualDiskNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.1
Description Identifies the instance number of the virtual disk entry.
Syntax Integer
Access Read-only

Virtual Disk Name

Name virtualDiskName
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.2
Description Identifies the virtual disk's label generated by Storage
Management or entered by the user.
Syntax DisplayString
Access Read-only

Virtual Device Disk Name

Name virtualDiskDeviceName
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.3
Description Identifies the device name used by this virtual disk's member
disks.
Syntax DisplayString
Access Read-only

Storage Management Group 657


book.book Page 658 Monday, March 14, 2011 3:01 PM

Virtual Disk State

Name virtualDiskState
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.4
Description Identifies the current state of this virtual disk. Possible states:
0: Unknown
1: Ready - The disk is accessible and has no known problems.
2: Failed - The data on the virtual disk is no longer fault tolerant
because one of the underlying disks is not online.
3: Online
4: Offline - The disk is not accessible. The disk may be corrupted
or intermittently unavailable.
6: Degraded - The data on the virtual disk is no longer fault
tolerant because one of the underlying disks is not online.
15: Resynching
16: Regenerating
24: Rebuilding
26: Formatting
32: Reconstructing
35: Initializing
36: Background Initialization
38: Resynching Paused
52: Permanently Degraded
54: Degraded Redundancy
Syntax Integer
Access Read-only

658 Storage Management Group


book.book Page 659 Monday, March 14, 2011 3:01 PM

Virtual Disk Severity

Name virtualDiskSeverity
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.5
Description This entry is obsolete for Storage Management. It was replaced
with RollUpStatus and ComponentStatus for each device.
Syntax Integer
Access Read-only

Virtual Disk Length in Megabytes

Name virtualDiskLengthInMB
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.6
Description Identifies the size of this virtual disk in megabytes. If this size is 0,
it is smaller than a megabyte.
Syntax Integer
Access Read-only

Virtual Disk Length in Bytes

Name virtualDiskLengthBytes
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.7
Description Identifies the portion of the virtual disk in bytes that is smaller
than a megabyte. This size plus the virtualDiskLengthInMB is the
total size of the virtual disk.
Syntax Integer
Access Read-only

Storage Management Group 659


book.book Page 660 Monday, March 14, 2011 3:01 PM

Virtual Disk Free Space in Megabytes

Name virtualDiskFreeSpaceInMB
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.8
Description This entry is obsolete. This property is not supported by virtual
disks managed under Storage Management.
Syntax Integer
Access Read-only

Virtual Disk Free Space in Bytes

Name virtualDiskFreeSpaceInBytes
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.9
Description This entry is obsolete. This property is not supported by virtual
disks managed under Storage Management.
Syntax Integer
Access Read-only

Virtual Disk Write Policy

Name virtualDiskWritePolicy
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.10
Description Indicates whether the controller's write cache are used when
writing to a virtual disk. Possible values:
1: Enabled - Adaptec Write Cache Enabled Protected
2: Disabled - Adaptec Write Cache Disabled
3: LSI Write Back
4: LSI Write Through
5: Enabled Always (Adaptec only)
6: Enabled Always (SAS only)
9: Not Applicable
Syntax Integer
Access Read-only

660 Storage Management Group


book.book Page 661 Monday, March 14, 2011 3:01 PM

Virtual Disk Read Policy

Name virtualDiskReadPolicy
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.11
Description Indicates whether the controller's read cache are used when
reading from a virtual disk. Possible values:
1: Enabled - Adaptec Read Cache Enabled
2: Disabled - Adaptec Read Cache Disabled
3: LSI Read Ahead
4: LSI Adaptive Read Ahead
5: LSI No Read Ahead
9: Not Applicable
Syntax Integer
Access Read-only

Virtual Disk Cache Policy

Name virtualDiskCachePolicy
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.12
Description Indicates whether the controller's cache is used when reading from
or writing to a virtual disk. Possible values:
1: Direct I/O (LSI)
2: Cached I/O (LSI)
99: Not Applicable
Syntax Integer
Access Read-only

Storage Management Group 661


book.book Page 662 Monday, March 14, 2011 3:01 PM

Virtual Disk Layout

Name virtualDiskLayout
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.13
Description Indicates the virtual disk's RAID type. Possible values:
1: Concatenated
2: RAID-0
3: RAID-1
7: RAID-5
8: RAID-6
10: RAID-10
12: RAID-50
19: Concatenated RAID 1
24: RAID-60
Syntax Integer
Access Read-only

Virtual Disk Current Stripe Size in Megabytes

Name virtualDiskCurStripeSizeInMB
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.14
Description Identifies the stripe size of this virtual disk in megabytes. If this
size is 0, it is smaller than a megabyte.
Syntax Integer
Access Read-only

662 Storage Management Group


book.book Page 663 Monday, March 14, 2011 3:01 PM

Virtual Disk Current Stripe Size in Bytes

Name virtualDiskCurStripeSizeInBytes
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.15
Description Identifies the portion of the stripe size in bytes that is smaller than
a megabyte. This size plus the virtualDiskCurStripeSizeInMB is
the total stripe size on the virtual disk.
Syntax Integer
Access Read-only

Virtual Disk Channel

Name virtualDiskChannel
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.16
Description This entry is obsolete. This property is not supported by virtual
disks managed under Storage Management.
Syntax Integer
Access Read-only

Virtual Disk Target ID

Name virtualDiskTargetID
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.17
Description Unique ID for the virtual disk.
Syntax Integer
Access Read-only

Virtual Disk LUN ID

Name virtualDiskLunID
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.18
Description This entry is obsolete. This property is not supported by virtual
disks managed under Storage Management.
Syntax Integer
Access Read-only

Storage Management Group 663


book.book Page 664 Monday, March 14, 2011 3:01 PM

Virtual Disk Roll-Up Status

Name virtualDiskRollUpStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.19
Description Severity of the virtual disk state. This is the combined status of the
virtual disk and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

Virtual Disk Component Status

Name virtualDiskComponentStatus
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.20
Description The status of the virtual disk itself without the propagation of any
contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax DellStatus
Access Read-only

664 Storage Management Group


book.book Page 665 Monday, March 14, 2011 3:01 PM

Virtual Disk Nexus ID

Name virtualDiskNexusID
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.21
Description Durable unique ID for this virtual disk.
Syntax DisplayString
Access Read-only

Virtual Disk Array Disk Type

Name virtualDiskArrayDiskType
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.22
Description Identifies the type of array (physical) disks used to create the
virtual disk. Possible values:
1: SAS
2: SATA
3: SCSI
4: IDE
99: Unknown
Syntax Integer
Access Read-only

Virtual Disk Bad Blocks Detected


Name virtualDiskBadBlocksDetected
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.23
Description Indicates if virtual disk has bad blocks.
Value: 0 - No, 1 - Yes, 2 - Not Applicable, 99 - Unknown
Syntax Integer
Access Read-only

Storage Management Group 665


book.book Page 666 Monday, March 14, 2011 3:01 PM

Virtual Disk Encrypted


Name virtualDiskEncrypted
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.24
Description Indicates if virtual disk is encrypted.
Value: 0 - No, 1 - Yes, 99 - Unknown
Syntax Integer
Access Read-only

Virtual Disk is CacheCade


Name virtualDiskIsCacheCade
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.25
Description Indicates if this virtual disk is configured as CacheCade.
Value: 1 - Yes, 0 - No, 99 - Undetermined
Syntax Integer
Access Read-only

Virtual Disk Disk Cache Policy


Name virtualDiskDiskCachePolicy
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.26
Description Indicates disk cache policy of the logical device.
Value: 1 - Enabled, 2 - Disabled, 99 - Undetermined
Syntax Integer
Access Read-only

Array Disk Logical Connection Table


This table describes the connections between array disks, the virtual disk to
which they belong, and their associated logical disk. For each object in the
table, its object number corresponds to an instance number in the
appropriate MIB table for that object where all of the object properties can be
found.

666 Storage Management Group


book.book Page 667 Monday, March 14, 2011 3:01 PM

The following object sets up the Array Disk Logical Connection Table.
Name arrayDiskLogicalConnectionTable
Object ID 1.3.6.1.4.1.674.10893.1.20.140.3
Description Defines the array disk logical connection table.
Syntax SEQUENCE OF arrayDiskLogicalConnectionEntry
Access Not accessible

Array Disk Logical Connection Entry

Name arrayDiskLogicalConnectionEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1
Description Defines the array disk logical connection table entry.
Syntax ArrayDiskLogicalConnectionEntry
Access Not accessible
Index arrayDiskLogicalConnectionNumber

Array Disk Logical Connection Number

Name arrayDiskLogicalConnectionNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.1
Description Identifies the instance number of the disk entry.
Syntax Integer
Access Read-only

Array Disk Logical Connection Array Disk Name

Name arrayDiskLogicalConnectionArrayDiskName
Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.2
Description Identifies the name of the array disk in this logical connection.
Syntax DisplayString
Access Read-only

Storage Management Group 667


book.book Page 668 Monday, March 14, 2011 3:01 PM

Array Disk Logical Connection Array Disk Number

Name arrayDiskLogicalConnectionArrayDiskNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.3
Description Identifies the instance number of the array disk in this logical
connection.
Syntax Integer
Access Read-only

Array Disk Logical Connection Virtual Disk Name

Name arrayDiskLogicalConnectionVirtualDiskName
Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.4
Description Identifies the name of the virtual disk to which this array disk
belongs.
Syntax DisplayString
Access Read-only

Array Disk Logical Connection Virtual Disk Number

Name arrayDiskLogicalConnectionVirtualDiskNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.5
Description Identifies the instance number of the virtual disk to which this
array disk belongs.
Syntax Integer
Access Read-only

Array Disk Logical Connection Disk Name

Name arrayDiskLogicalConnectionDiskName
Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.6
Description Identifies the name of the disk group to which this array disk
belongs. This property is currently not supported.
Syntax DisplayString
Access Read-only

668 Storage Management Group


book.book Page 669 Monday, March 14, 2011 3:01 PM

Array Disk Logical Connection Disk Number

Name arrayDiskLogicalConnectionDiskNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.7
Description Identifies the instance number of the disk group to which this
array disk belongs. This property is currently not supported.
Syntax Integer
Access Read-only

Storage Management Event Group


The Storage Management Event Group defines the properties that are sent
with SNMP traps.

Message ID Event

Name messageIDEvent
Object ID 1.3.6.1.4.1.674.10893.1.20.200.1
Description Storage Management event message number.
Syntax Integer
Access Read-only

Description Event

Name descriptionEvent
Object ID 1.3.6.1.4.1.674.10893.1.20.200.2
Description Storage Management event message text describing the alert.
Syntax DisplayString
Access Read-only

Location Event
Name locationEvent
Object ID 1.3.6.1.4.1.674.10893.1.20.200.3

Storage Management Group 669


book.book Page 670 Monday, March 14, 2011 3:01 PM

Name locationEvent
Description Additional information identifying the location of the object
causing the alert.
Syntax DisplayString
Access Read-only

Object Name Event


Name objectNameEvent
Object ID 1.3.6.1.4.1.674.10893.1.20.200.4
Description Name of the object as represented in Storage Management
causing the alert.
Syntax DisplayString
Access Read-only

Object OID Event

Name objectOIDEvent
Object ID 1.3.6.1.4.1.674.10893.1.20.200.5
Description MIB OID of the object causing the alert.
Syntax DisplayString
Access Read-only

Object Nexus Event

Name objectNexusEvent
Object ID 1.3.6.1.4.1.674.10893.1.20.200.6
Description Durable, unique ID of the object causing the alert.
Syntax DisplayString
Access Read-only

670 Storage Management Group


book.book Page 671 Monday, March 14, 2011 3:01 PM

Current Status Event

Name currentStatusEvent
Object ID 1.3.6.1.4.1.674.10893.1.20.200.7
Description Current status of object causing the alert, if applicable.
Syntax DellStatus
Access Read-only

Previous Status Event

Name previousStatusEvent
Object ID 1.3.6.1.4.1.674.10893.1.20.200.8
Description Previous status of object causing the alert if applicable.
Syntax DellStatus
Access Read-only

Storage Management Group 671


book.book Page 672 Monday, March 14, 2011 3:01 PM

672 Storage Management Group


book.book Page 673 Monday, March 14, 2011 3:01 PM

25
Change Management Group
The Change Management Group lets you monitor information about the
Dell devices and software that are present on a particular managed computer
chassis. This information is collected during an inventory scan.

Inventory Group
The following objects describe the fields for inventory information.

Inventory Locale

Name inventoryLocale
Object ID 1.3.6.1.4.1.674.10899.1.1
Description Defines the locale of the system.
Syntax DisplayString
Access Read-only

Inventory Schema Version

Name inventorySchemaVersion
Object ID 1.3.6.1.4.1.674.10899.1.2
Description Defines the inventory schema implemented by this system.
Syntax DisplayString
Access Read-only

Inventory System ID

Name inventorySystemID
Object ID 1.3.6.1.4.1.674.10899.1.3
Description Defines the System ID for the system.
Syntax SystemID

Change Management Group 673


book.book Page 674 Monday, March 14, 2011 3:01 PM

Name inventorySystemID
Access Read-only

Device Group
The Device Group defines information about the devices discovered on the
system during an inventory scan. Identifying information includes the
Component ID, the Device ID, and the Vendor ID.

Device Group Table


The following object sets up the Device Group Table.

Name deviceTable
Object ID 1.3.6.1.4.1.674.10899.1.5
Description Defines the Device Table.
Syntax SEQUENCE OF DeviceEntry
Access Not accessible

Device Entry

Name deviceEntry
Object ID 1.3.6.1.4.1.674.10899.1.5.1
Description Defines a device entry.
Syntax DeviceEntry
Access Not accessible

Device Index

Name deviceIndex
Object ID 1.3.6.1.4.1.674.10899.1.5.1.1
Description Defines the unique index for this device.
Syntax Unsigned16BitRange
Access Read-only

674 Change Management Group


book.book Page 675 Monday, March 14, 2011 3:01 PM

Device Component ID

Name deviceComponentID
Object ID 1.3.6.1.4.1.674.10899.1.5.1.2
Description Defines an optional component ID field for the device.
Syntax Integer
Access Read-only

Device Display String

Name deviceDisplayString
Object ID 1.3.6.1.4.1.674.10899.1.5.1.3
Description Provides a displayable string that describes the device.
Syntax DisplayString
Access Read-only

Device Vendor ID

Name deviceVendorID
Object ID 1.3.6.1.4.1.674.10899.1.5.1.4
Description Defines the ID for the vendor supplying the device.
Syntax Octet String
Access Read-only

Device ID

Name deviceDeviceID
Object ID 1.3.6.1.4.1.674.10899.1.5.1.5
Description Defines the ID for the device.
Syntax Octet String
Access Read-only

Change Management Group 675


book.book Page 676 Monday, March 14, 2011 3:01 PM

Device Sub ID

Name deviceSubID
Object ID 1.3.6.1.4.1.674.10899.1.5.1.6
Description Provides additional device identification.
Syntax Octet String
Access Read-only

Device Sub Vendor ID

Name deviceSubVendorID
Object ID 1.3.6.1.4.1.674.10899.1.5.1.7
Description Provides additional vendor identification.
Syntax Octet String
Access Read-only

Application Group
NOTE: Dell updateable components such as Basic input/output system (BIOS) and
FirmWare (FW) are considered applications. For example, the following would be
returned for system BIOS: Application/DisplayString = BIOS
Application/Version = A10
The Application Group defines information about the applications
discovered on the system during an inventory scan. Identifying information
includes the application type, the application version, and the application
description.

676 Change Management Group


book.book Page 677 Monday, March 14, 2011 3:01 PM

Application Group Table


The following object sets up the Application Group Table.

Name applicationTable
Object ID 1.3.6.1.4.1.674.10899.1.6
Description Defines a table of application information for the system.
Syntax SEQUENCE OF ApplicationEntry
Access Not accessible

Application Entry

Name applicationEntry
Object ID 1.3.6.1.4.1.674.10899.1.6.1
Description Defines an application entry.
Syntax ApplicationEntry
Access Read-only

Application Index

Name applicationIndex
Object ID 1.3.6.1.4.1.674.10899.1.6.1.1
Description Defines the unique index for this application.
Syntax Unsigned16BitRange
Access Read-only

Application Device Index

Name applicationDeviceIndex
Object ID 1.3.6.1.4.1.674.10899.1.6.1.2
Description Defines a cross-index to the device table for the application.
Syntax Unsigned16BitRange
Access Read-only

Change Management Group 677


book.book Page 678 Monday, March 14, 2011 3:01 PM

Application Component Type

Name applicationComponentType
Object ID 1.3.6.1.4.1.674.10899.1.6.1.3
Description Identifies the type of application reported.
Syntax DisplayString
Access Read-only

Application Version

Name applicationVersion
Object ID 1.3.6.1.4.1.674.10899.1.6.1.4
Description Identifies the version of the application.
Syntax DisplayString
Access Read-only

Application Display String

Name applicationDisplayString
Object ID 1.3.6.1.4.1.674.10899.1.6.1.5
Description A user visible display string that describes the application.
Syntax DisplayString
Access Read-only

Application Sub-Component ID

Name applicationSubComponentID
Object ID 1.3.6.1.4.1.674.10899.1.6.1.6
Description The sub-component ID for the application. This is usually valid
on ESM device reporting.
Syntax DisplayString
Access Read-only

678 Change Management Group


book.book Page 679 Monday, March 14, 2011 3:01 PM

Operating System Group


The Operating System Group provides status and identifying information about
a system’s operating system. Identifying information includes the name,
version, and service pack of the installed operating system.
The following objects describe the fields for Operating System Group.

Operating System Vendor

Name operatingSystemVendor
Object ID 1.3.6.1.4.1.674.10899.2.1
Description Defines the vendor of the Operating System.
Syntax DisplayString
Access Read-only

Operating System Major Version

Name operatingSystemMajorVersion
Object ID 1.3.6.1.4.1.674.10899.2.2
Description Defines the major version of the Operating System.
Syntax DisplayString
Access Read-only

Operating System Minor Version

Name operatingSystemMinorVersion
Object ID 1.3.6.1.4.1.674.10899.2.3
Description Defines the minor version of the Operating System.
Syntax DisplayString
Access Read-only

Change Management Group 679


book.book Page 680 Monday, March 14, 2011 3:01 PM

Operating System Service Pack Major Version

Name operatingSystemSPMajorVersion
Object ID 1.3.6.1.4.1.674.10899.2.5
Description Defines the Operating System's Service Pack major version.
Syntax DisplayString
Access Read-only

Operating System Service Pack Minor Version

Name operatingSystemSPMinorVersion
Object ID 1.3.6.1.4.1.674.10899.2.6
Description Defines the Operating System's Service Pack minor version.
Syntax DisplayString
Access Read-only

Operating System Architecture

Name operatingSystemArchitecture
Object ID 1.3.6.1.4.1.674.10899.2.7
Description Defines the Operating System's architecture.
Syntax DisplayString
Access Read-only

Inventory Collector Product Information


The following objects describe the fields for the Inventory Collector. The
Inventory Collector product variables are scalar objects, meaning that they
are not related to other Inventory Collector base (MIB) objects and are thus
not placed in a table.

680 Change Management Group


book.book Page 681 Monday, March 14, 2011 3:01 PM

Product ID Display Name

Name productIDDisplayName
Object ID 1.3.6.1.4.1.674.10899.100.1
Description Defines the display name of the product.
Syntax DisplayString
Access Read-only

Product ID Description

Name productIDDescription
Object ID 1.3.6.1.4.1.674.10899.100.2
Description Provides a description of the product.
Syntax DisplayString
Access Read-only

Product ID Vendor

Name productIDVendor
Object ID 1.3.6.1.4.1.674.10899.100.3
Description Provides name of the manufacturer of the product.
Syntax DisplayString
Access Read-only

Product ID Version

Name productIDVersion
Object ID 1.3.6.1.4.1.674.10899.100.4
Description Describes the version of the product.
Syntax DisplayString
Access Read-only

Change Management Group 681


book.book Page 682 Monday, March 14, 2011 3:01 PM

Product ID Build Number

Name productIDBuildNumber
Object ID 1.3.6.1.4.1.674.10899.100.5
Description Describes the software build number of the product.
Syntax DisplayString
Access Read-only

682 Change Management Group


book.book Page 683 Monday, March 14, 2011 3:01 PM

26
Dell Remote Access Controller Out-
of-Band Group
The Dell Remote Access Controller Out-of-Band MIB contains information
for both Chassis Management Controller (CMC) and RAC Legacy Alerting.
This MIB consists of information for the following groups:

Product Information
The following MIB tables define the Dell RAC Out-of-Band group:

DRsProductName

Name DRsProductName
Object ID 1.3.6.1.4.1.674.10892.2.1.1.1
Description Defines the product name of a chassis management controller.
Syntax DellString
Access Read-only

DRsProductShortName

Name DRsProductShortName
Object ID 1.3.6.1.4.1.674.10892.2.1.1.2
Description Defines the short product name of a chassis management controller.
Syntax DellString
Access Read-only

Dell Remote Access Controller Out-of-Band Group 683


book.book Page 684 Monday, March 14, 2011 3:01 PM

DRsProductDescription

Name DRsProductDescription
Object ID 1.3.6.1.4.1.674.10892.2.1.1.3
Description Defines the product description of a chassis management controller.
Syntax DellString
Access Read-only

DRsProductManufacturer

Name DRsProductManufacturer
Object ID 1.3.6.1.4.1.674.10892.2.1.1.4
Description Defines the product manufacturer of a chassis management
controller.
Syntax DellString
Access Read-only

DRsProductVersion

Name DRsProductVersion
Object ID 1.3.6.1.4.1.674.10892.2.1.1.5
Description Defines the product version of a chassis management controller.
Syntax DellString
Access Read-only

DRsChassisServiceTag

Name DRsChassisServiceTag
Object ID 1.3.6.1.4.1.674.10892.2.1.1.6
Description Defines the Service Tag of the chassis.
Syntax DellString
Access Read-only

684 Dell Remote Access Controller Out-of-Band Group


book.book Page 685 Monday, March 14, 2011 3:01 PM

DRsProductURL
Name DrsProductURL
Object ID 1.3.6.1.4.1.674.10892.2.1.1.7
Description Defines the out-of-band UI URL of a chassis management
controller.
Syntax DellString
Access Read-only

DRsProductChassisAssetTag
Name DRsProductChassisAssetTag
Object ID 1.3.6.1.4.1.674.10892.2.1.1.8
Description Defines the Asset Tag of the chassis.
Syntax DellString
Access Read-only

DRsProductChassisLocation
Name DRsProductChassisLocation
Object ID 1.3.6.1.4.1.674.10892.2.1.1.9
Description Defines the location of the chassis.
Syntax DellString
Access Read-only

DRsProductChassisName
Name DrsProductChassisName
Object ID 1.3.6.1.4.1.674.10892.2.1.1.10
Description Defines the name of the chassis.
Syntax DellString
Access Read-only

Dell Remote Access Controller Out-of-Band Group 685


book.book Page 686 Monday, March 14, 2011 3:01 PM

DRsSystemServiceTag
Name DRsSystemServiceTag
Object ID 1.3.6.1.4.1.674.10892.2.1.1.11
Description Defines the service tag of a system.
Syntax DellString
Access Read-only

DRsProductSystemAssetTag
Name DRsProductSystemAssetTag
Object ID 1.3.6.1.4.1.674.10892.2.1.1.12
Description Defines the asset tag of a system.
Syntax DellString
Access Read-only

DRsProductSystemSlot
Name DRsProductSystemSlot
Object ID 1.3.6.1.4.1.674.10892.2.1.1.13
Description Defines the slot number of a CMC.
Syntax DellString
Access Read-only

DRsProductType
Name DRsProductType
Object ID 1.3.6.1.4.1.674.10892.2.1.1.14
Description Defines type of a remote access card.
Syntax DellRacType
Access Read-only

686 Dell Remote Access Controller Out-of-Band Group


book.book Page 687 Monday, March 14, 2011 3:01 PM

DRsFirmwareVersion
Name DRsFirmwareVersion
Object ID 1.3.6.1.4.1.674.10892.2.1.2.1
Description Defines the firmware version of a chassis management controller.
Syntax DellString
Access Read-only

Chassis Status
The following MIB tables provide information on Chassis being monitored by
the chassis management card.

DRsGlobalSystemStatus

Name DRsGlobalSystemStatus
Object ID 1.3.6.1.4.1.674.10892.2.2.1
Description Defines the overall chassis status being monitored by the chassis
management card.
Syntax DellStatus
Access Read-only

DRsGlobalCurrStatus

Name DRsGlobalCurrStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.1.1
Description Defines the overall chassis status being monitored by the chassis
management card.
Syntax DellStatus
Access Read-only

Dell Remote Access Controller Out-of-Band Group 687


book.book Page 688 Monday, March 14, 2011 3:01 PM

DRsIOMCurrStatus

Name DRsIOMCurrStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.1.2
Description Defines the IOM subsystem status being monitored by the chassis
management card.
Syntax DellStatus
Access Read-only

DRsKVMCurrStatus

Name DRsKVMCurrStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.1.3
Description Defines the iKVM subsystem health status being monitored by the
chassis management card.
Syntax DellStatus
Access Read-only

DRsRedCurrStatus

Name DRsRedCurrtatus
Object ID 1.3.6.1.4.1.674.10892.2.3.1.4
Description Defines the redundancy status being monitored by the chassis
management card.
Syntax DellStatus
Access Read-only

688 Dell Remote Access Controller Out-of-Band Group


book.book Page 689 Monday, March 14, 2011 3:01 PM

DRsPowerCurrStatus

Name DRsPowerCurrStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.1.5
Description Defines the power subsystem health status being monitored by the
chassis management card.
Syntax DellStatus
Access Read-only

DRsFanCurrStatus

Name DRsFanCurrStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.1.6
Description Defines the fan subsystem health status being monitored by the
chassis management card.
Syntax DellStatus
Access Read-only

DRsBladeCurrStatus

Name DRsBladeCurrStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.1.7
Description Defines the blade subsystem health status being monitored by the
chassis management card.
Syntax DellStatus
Access Read-only

Dell Remote Access Controller Out-of-Band Group 689


book.book Page 690 Monday, March 14, 2011 3:01 PM

DRsTempCurrStatus

Name DRsTempCurrStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.1.8
Description Defines the temperature sensor subsystem health status being
monitored by the chassis management card.
Syntax DellStatus
Access Read-only

DRsCMCCurrStatus

Name DRsCMCCurrStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.1.9
Description Defines the CMC health status being monitored by the chassis
management card.
Syntax DellStatus
Access Read-only

DRsChassisFrontPanelAmbientTemperature

Name drsChassisFrontPanelAmbientTemperature
Object ID 1.3.6.1.4.1.674.10892.2.3.1.10
Description Defines the ambient temperature reading (in degrees Celsius) for
the chassis front panel controller.
Syntax DellTemperatureReading
Access Read-only

690 Dell Remote Access Controller Out-of-Band Group


book.book Page 691 Monday, March 14, 2011 3:01 PM

DRsCMAmbientTemperature

Name drsCMCAmbientTemperature
Object ID 1.3.6.1.4.1.674.10892.2.3.1.11
Description Defines the ambient temperature reading (in degrees Celsius) for
the chassis management card.
Syntax DellTemperatureReading
Access Read-only

DRsCMProcessorTemperature

Name drsCMCProcessorTemperature
Object ID 1.3.6.1.4.1.674.10892.2.3.1.12
Description Defines the temperature reading (in degrees Celsius) for the chassis
management card. processor.
Syntax DellTemperatureReading
Access Read-only

DRsGlobalPrevStatus

Name DRsGlobalPrevStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.2.1
Description Defines the previous chassis status recorded by the chassis
management card.
Syntax DellStatus
Access Read-only

Dell Remote Access Controller Out-of-Band Group 691


book.book Page 692 Monday, March 14, 2011 3:01 PM

DRsIOMPrevStatus

Name DRsIOMPrevStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.2.2
Description Defines the previous IOM subsystem status recorded by the chassis
management card.
Syntax DellStatus
Access Read-only

DRsKVMPrevStatus

Name DRsKVMPrevStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.2.3
Description Defines the previous iKVM subsystem health status recorded by the
chassis management card.
Syntax DellStatus
Access Read-only

DRsRedPrevStatus

Name DRsRedPrevStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.2.4
Description Defines the previous redundancy status recorded by the chassis
management card.
Syntax DellStatus
Access Read-only

692 Dell Remote Access Controller Out-of-Band Group


book.book Page 693 Monday, March 14, 2011 3:01 PM

DRsPowerPrevStatus

Name DRsPowerPrevStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.2.5
Description Defines the previous power subsystem health status recorded by the
chassis management card.
Syntax DellStatus
Access Read-only

DRsFanPrevStatus

Name DrsFanPrevStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.2.6
Description Defines the previous fan health status being monitored by the
chassis management card.
Syntax DellStatus
Access Read-only

DRsBladePrevStatus

Name DRsBladePrevStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.2.7
Description Defines the previous blade subsystem health status recorded by the
chassis management card.
Syntax DellStatus
Access Read-only

Dell Remote Access Controller Out-of-Band Group 693


book.book Page 694 Monday, March 14, 2011 3:01 PM

DRsTempPrevStatus

Name DRsTempPrevStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.2.8
Description Defines the temperature sensor health status being monitored by
the chassis management card.
Syntax DellStatus
Access Read-only

DRsCMCPrevStatus

Name DRsCMCPrevStatus
Object ID 1.3.6.1.4.1.674.10892.2.3.2.9
Description Defines the CMC health status being monitored by the chassis
management card.
Syntax DellStatus
Access Read-only

DRsGlobalChangeTime

Name DRsGlobalChangeTime
Object ID 1.3.6.1.4.1.674.10892.2.3.3.1
Description Defines the timestamp of the most recent global status change.
Syntax TimeTicks
Access Read-only

DRsIOMChangeTime

Name DRsIOMChangeTime
Object ID 1.3.6.1.4.1.674.10892.2.3.3.2
Description Defines the timestamp of the most recent IOM status change.
Syntax TimeTicks
Access Read-only

694 Dell Remote Access Controller Out-of-Band Group


book.book Page 695 Monday, March 14, 2011 3:01 PM

DRsKVMChangeTime

Name DRsKVMChangeTime
Object ID 1.3.6.1.4.1.674.10892.2.3.3.3
Description Defines the timestamp of the most recent iKVM status change.
Syntax TimeTicks
Access Read-only

DRsRedChangeTime

Name DRsRedChangeTime
Object ID 1.3.6.1.4.1.674.10892.2.3.3.4
Description Defines the timestamp of the most recent Redundancy status
change.
Syntax TimeTicks
Access Read-only

DRsPowerChangeTime

Name DRsPowerChangeTime
Object ID 1.3.6.1.4.1.674.10892.2.3.3.5
Description Defines the timestamp of the most recent power health status
change.
Syntax TimeTicks
Access Read-only

DRsFanChangeTime

Name DRsFanChangeTime
Object ID 1.3.6.1.4.1.674.10892.2.3.3.6
Description Defines the timestamp of the most recent fan health status change.
Syntax TimeTicks
Access Read-only

Dell Remote Access Controller Out-of-Band Group 695


book.book Page 696 Monday, March 14, 2011 3:01 PM

DRsBladeChangeTime

Name DRsBladeChangeTime
Object ID 1.3.6.1.4.1.674.10892.2.3.3.7
Description Defines the timestamp of the most recent blade health status
change.
Syntax TimeTicks
Access Read-only

DRsTempChangeTime
Name DRsTempChangeTime
Object ID 1.3.6.1.4.1.674.10892.2.3.3.8
Description Defines the timestamp of the most recent temperature sensor
health status change.
Syntax TimeTicks
Access Read-only

DRsCMCChangeTime
Name DRsCMCChangeTime
Object ID 1.3.6.1.4.1.674.10892.2.3.3.9
Description Defines the timestamp of the most recent CMC health status
change.
Syntax TimeTicks
Access Read-only

696 Dell Remote Access Controller Out-of-Band Group


book.book Page 697 Monday, March 14, 2011 3:01 PM

Chassis Power
The following MIB tables provide information on the chassis management
controller table entry.

DRsCMC Power Table

Name DRsCMCPowerTable
Object ID 1.3.6.1.4.1.674.10892.2.4.1
Description Defines the CMC power table.
Syntax SEQUENCE OF DrsCMCPowerTableEntry
Access Not-accessible

DRsCMC Power Table Entry

Name DRsCMCPowerTableEntry
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1
Description Defines the CMC power table entry.
Syntax DrsCMCPowerTableEntry
Access Not-accessible

DRsCMC PSUTable

Name DrsCMCPSUTable
Object ID 1.3.6.1.4.1.674.10892.2.4.2
Description Defines the CMC PSU table.
Syntax SEQUENCE OF DrsCMCPSUTableEntry
Access Not-accessible

Dell Remote Access Controller Out-of-Band Group 697


book.book Page 698 Monday, March 14, 2011 3:01 PM

DRsCMC PSUTableEntry

Name DrsCMCPSUTableEntry
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1
Description Defines the CMC PSU table entry.
Syntax DrsCMCPSUTableEntry
Access Not-accessible

CMC Power Information


The following MIB tables provide information on the chassis power.

DRsChassisIndex

Name DrsChassisIndex
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellCMCPowerIndexRange
Access Read-only

DRsPotentialPower

Name DRsPotentialPower
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.2
Description Defines the power (in Watts) required by the chassis infrastructure,
plus the sum of the maximum power requirements for all systems
currently turned on.
Syntax DellPowerReading
Access Read-only

698 Dell Remote Access Controller Out-of-Band Group


book.book Page 699 Monday, March 14, 2011 3:01 PM

DRsIdlePower

Name DRsIdlePower
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.3
Description Defines the power (in Watts) required by the chassisinfrastructure,
plus the sum of the minimum power requirements for all systems
currently turned on.
Syntax DellPowerReading
Access Read-only

DRsMaxPowerSpecification

Name DRsMaxPowerSpecification
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.4
Description Defines the power limit (in Watts) at which server throttling takes
place.
Syntax DellPowerReading
Access Read-only

DRsPowerSurplus

Name DRsPowerSurplus
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.5
Description Defines the power surplus (in Watts) remaining above the
drsPotentialPower reading.
Syntax DellPowerReading
Access Read-only

Dell Remote Access Controller Out-of-Band Group 699


book.book Page 700 Monday, March 14, 2011 3:01 PM

DRsKWhCumulative

Name DRsKWhCumulative
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.6
Description Defines the cumulative chassis power usage (in KWh) since last
reset.
Syntax DellPowerReading
Access Read-only

DRsKWhCumulativeTime

Name DRsKWhCumulativeTime
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.7
Description Defines the timestamp of the most recent chassis power
accumulator reset.
Syntax DellTimestamp
Access Read-only

DRsWattsPeakUsage

Name DRsWattsPeakUsage
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.8
Description Defines the chassis peak power usage (in Watts) since last reset.
Syntax DellPowerReading
Access Read-only

DRsWattsPeakTime

Name DRsWattsPeakTime
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.9
Description Defines the timestamp of the most recent chassis peak power usage.
Syntax DellTimestamp
Access Read-only

700 Dell Remote Access Controller Out-of-Band Group


book.book Page 701 Monday, March 14, 2011 3:01 PM

DRsWattsMinUsage

Name DRsWattsMinUsage
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.10
Description Defines the chassis minimum power usage (in Watts) since last
reset.
Syntax DellPowerReading
Access Read-only

DRsWattsMinTime

Name DRsWattsMinTime
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.11
Description Defines the timestamp of the most recent chassis minimum power
usage.
Syntax DellPowerReading
Access Read-only

DRsWattsResetTime

Name DRsWattsResetTime
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.12
Description Defines the timestamp of the most recent reset of the chassis
minimum/maximum Watts readings.
Syntax DellTimestamp
Access Read-only

Dell Remote Access Controller Out-of-Band Group 701


book.book Page 702 Monday, March 14, 2011 3:01 PM

DRsWattsReading

Name DRsWattsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.13
Description Defines the instantaneous chassis power usage (in Watts)
Syntax DellPowerReading
Access Read-only

DRsAmpsReading

Name DRsAmpsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.14
Description Defines the instantaneous chassis current usage (in Watts).
Syntax DellPowerReading
Access Read-only

CMC PSU Information


The following MIB tables provide information on the chassis power
supply unit.

DRsPSUChassisIndex

Name DRsPSUChassisIndex
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellCMCPowerIndexRange
Access Read-only

702 Dell Remote Access Controller Out-of-Band Group


book.book Page 703 Monday, March 14, 2011 3:01 PM

DRsPSUIndex

Name DRsPSUIndex
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.2
Description Defines the index (one-based) of the associated CMC PSU.
Syntax DellCMCPSUIndexRange
Access Read-only

DRsPSULocation

Name DRsPSULocation
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.3
Description Defines the location of the CMC PSU.
Syntax DellString
Access Read-only

DRsPSUMonitoringCapable

Name DRsPSUMonitoringCapable
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.4
Description Defines the PSU Monitoring capabilities, or the absence of a PSU in
this location.
Syntax DellCMCPSUCapable
Access Read-only

DRsPSUVoltsReading

Name DRsPSUVoltsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.5
Description Defines the instantaneousPSU Voltage reading.
Syntax DellPowerReading
Access Read-only

Dell Remote Access Controller Out-of-Band Group 703


book.book Page 704 Monday, March 14, 2011 3:01 PM

DRsPSUAmpsReading

Name DRsPSUAmpsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.6
Description Defines the instantaneous PSU Current reading.
Syntax DellPowerReading
Access Read-only

DRsPSUWattsReading

Name DrsPSUWattsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.7
Description Defines the instantaneous PSU Wattage reading.
Syntax DellPowerReading
Access Read-only

Chassis Alerts
The following MIB tables provide information on the chassis management
controller alerts.

DRsCASubSystem

Name DrsCASubSystem
Object ID 1.3.6.1.4.1.674.10892.2.20.10.1
Description Defines the Sub-System Name of the CMC Alert.
Syntax DellString
Access Read-only

704 Dell Remote Access Controller Out-of-Band Group


book.book Page 705 Monday, March 14, 2011 3:01 PM

DrsCASSCurrStatus

Name DrsCASSCurrStatus
Object ID 1.3.6.1.4.1.674.10892.2.20.10.2
Description Defines the Current Status of the Alerting Sub-System.
Syntax DellStatus
Access Read-only

DrsCASSPrevStatus

Name DrsCASSPrevStatus
Object ID 1.3.6.1.4.1.674.10892.2.20.10.3
Description Defines the Previous Status of the Alerting Sub-System.
Syntax DellStatus
Access Read-only

DrsCASSChangeTime

Name DrsCASSChangeTime
Object ID 1.3.6.1.4.1.674.10892.2.20.10.4
Description Defines the timestamp of Most Recent Change of the Alerting Sub-
System.
Syntax TimeTicks
Access Read-only

DrsCAMessage

Name DrsCAMessage
Object ID 1.3.6.1.4.1.674.10892.2.20.10.5
Description Defines the CSSD message of the CMC Alert.
Syntax DellString
Access Read-only

Dell Remote Access Controller Out-of-Band Group 705


book.book Page 706 Monday, March 14, 2011 3:01 PM

Legacy Alerting
The following MIB tables provide information on the RAC legacy alerting.

DRsAlertSystem

Name DRsAlertSystem
Object ID 1.3.6.1.4.1.674.10892.2.5000.10.1
Description Name of the system generating the alert.
Syntax Octet String(SIZE (0..255))
Access Read-only

DRsAlertTableIndexOID

Name DRsAlertTableIndexOID
Object ID 1.3.6.1.4.1.674.10892.2.5000.10.2
Description Alert Index Object Identifier.
Syntax OBJECT IDENTIFIER
Access Read Only

DRsAlertMessage

Name DRsAlertMessage
Object ID 1.3.6.1.4.1.674.10892.2.5000.10.3
Description Message describing the alert.
Syntax Octet String (SIZE (0..1024))
Access Read-only

706 Dell Remote Access Controller Out-of-Band Group


book.book Page 707 Monday, March 14, 2011 3:01 PM

DRsAlertCurrentStatus

Name DRsAlertCurrentStatus
Object ID 1.3.6.1.4.1.674.10892.2.5000.10.4
Description Current status of object causing the alert.
Syntax DellStatus
Access Read-only

DRsAlertPreviousStatus

Name DRsAlertPreviousStatus
Object ID 1.3.6.1.4.1.674.10892.2.5000.10.5
Description Previous status of object causing the alert.
Syntax DellStatus
Access Read-only

DRsAlertData

Name DRsAlertData
Object ID 1.3.6.1.4.1.674.10892.2.5000.10.6
Description Alert data
Syntax Octet String (SIZE (0..1024))
Access Read-only

Dell Remote Access Controller Out-of-Band Group 707


book.book Page 708 Monday, March 14, 2011 3:01 PM

708 Dell Remote Access Controller Out-of-Band Group


book.book Page 709 Monday, March 14, 2011 3:01 PM

27
Traps
The Server Administrator generates events that result in Simple Network
Management Protocol (SNMP) traps or operating system event logs. Remote
Access Controller (RAC) and Baseboard Management Controller (BMC) can
also generate SNMP traps in response to hardware events. This section
describes the traps, also known as alerts, generated by the Server
Administrator, RAC, and BMC.
The Server Administrator generates events in response to changes in the
status of sensors and other monitored parameters. When an event with
predefined characteristics occurs on your system, the SNMP subagent sends
information about the event, along with trap variables, to the
management console.
Each status change event generates a unique identifier called the trap ID and
a trap description that describes the event. The trap ID and message uniquely
describe the severity and cause of the event, and provide other relevant
information such as the location of the event and the monitored item’s
previous state.
"Instrumentation Traps" on page 716 lists all Server Administrator
Instrumentation trap IDs in numerical order and includes each trap ID’s
corresponding description, severity level, and cause. Description text in
brackets (for example, <State>) describes the event-specific information
provided by Server Administrator.
"RAC Traps" on page 742 lists RAC trap IDs in numerical order and includes
each trap ID’s corresponding description, severity level, and cause.
"BMC Traps" on page 748 lists BMC trap IDs and includes each trap ID’s
corresponding description and severity level.

Traps 709
book.book Page 710 Monday, March 14, 2011 3:01 PM

Trap Variables
This section describes the variables that are sent to the management console
to provide additional information about a trap or alert generated by some
event on your system. The trap variables presented here apply to all
Instrumentation and RAC traps. Trap variables are sent in the order listed and
are reserved for use only in traps. When a varbind is created for a trap
variable, a zero is appended to the object ID (OID) to create the OID for
the varbind.

System

Variable Name alertSystem


Object ID 1.3.6.1.4.1.674.10892.1.5000.10.1
Description Identifies the system generating the alert.
Syntax DisplayString (SIZE (0..255))

Table Index OID

Variable Name alertTableIndexOID


Object ID 1.3.6.1.4.1.674.10892.1.5000.10.2
Description Gives the object identifier for the index attribute in the table
that contains the object causing the alert. Uniquely
identifies the object causing the alert and can be used to
correlate different alerts caused by the same object.
Syntax OBJECT IDENTIFIER

Message

Variable Name alertMessage


Object ID 1.3.6.1.4.1.674.10892.1.5000.10.3
Description Describes the alert.
Syntax DisplayString (SIZE (0..1024))

710 Traps
book.book Page 711 Monday, March 14, 2011 3:01 PM

Current Status

Variable Name alertCurrentStatus


Object ID 1.3.6.1.4.1.674.10892.1.5000.10.4
Description Gives the current status of the object causing the alert.
Syntax DellStatus

Previous Status

Variable Name alertPreviousStatus


Object ID 1.3.6.1.4.1.674.10892.1.5000.10.5
Description Gives the previous status of the object causing the alert.
Syntax DellStatus

Data

Variable Name alertData


Object ID 1.3.6.1.4.1.674.10892.1.5000.10.6
Description Provides Server Administrator-defined data related to the
alert.
Syntax Octet String (SIZE (0..1024))

Understanding the Trap Description


Table 27-1 lists in alphabetical order each line item that may appear in the
trap description.

Table 27-1. Trap Description Reference

Description Line Item Explanation


Action performed was: Specifies the automatic server recovery action
<Action> that was performed, for example:
Action performed was: Power
cycle

Traps 711
book.book Page 712 Monday, March 14, 2011 3:01 PM

Table 27-1. Trap Description Reference (continued)

Description Line Item Explanation


Action requested was: Specifies the user initiated host control action
<Action> that was requested, for example:
Action requested was: Reboot,
shutdown OS first
Additional details: Specifies possible additional details about the
<Additional details for specified device, for example:
the events> Additional details:
Memory device: DIMM_1A Serial
number: 11111111
Memory device: DIMM_1B Serial
number: 22222222
<Additional power Specifies any additional power supply
supply status information pertaining to the event, for
information> example:
Power supply input AC is off,
Power supply POK (power OK)
signal is not normal, Power
supply is turned off
Battery sensor status: Specifies the status reported by the battery
<status> sensor, for example:
Battery sensor status:
Predictive failure
Chassis intrusion Specifies the chassis intrusion state (open or
state: closed), for example:
<Intrusion state> Chassis intrusion state: Open
Chassis location: Specifies the name of the chassis that
<Name of chassis> generated the message, for example:
Chassis location: Main System
Chassis
Configuration error Specifies the type of configuration error that
type: <type of occurred, for example:
configuration error> Configuration error type:
Revision mismatch

712 Traps
book.book Page 713 Monday, March 14, 2011 3:01 PM

Table 27-1. Trap Description Reference (continued)

Description Line Item Explanation


Current sensor value Specifies the current sensor value in amps,
(in Amps): <Reading> for example:
Current sensor value: 7.853
Date and time of Specifies the date and time that an automatic
action: <Date and time> server recovery action was performed, for
example:
Date and time of action:
Fri May 30 23:55:44 2003.
Description: Specifies the description of the event that
<Description of event> occurred, for example:
Description: Chipset Err:
Critical Event sensor, front
panel NMI / diagnostic interrupt
was asserted.
Device location: Specifies the location of the device in the
<Location in chassis> specified chassis, for example:
Device location: Mem Card A
Discrete current state: Specifies the state of the current sensor, for
<State> example:
Discrete current state: Good
Discrete temperature Specifies the state of the temperature sensor,
state: <State> for example:
Discrete temperature state:
Good
Discrete voltage state: Specifies the state of the voltage sensor, for
<State> example:
Discrete voltage state: Good
Fan sensor value: Specifies the fan speed in revolutions per
<Reading> minute (RPMs) or On/Off, for example:
Fan sensor value (in RPM): 2600
Fan sensor value: Off

Traps 713
book.book Page 714 Monday, March 14, 2011 3:01 PM

Table 27-1. Trap Description Reference (continued)

Description Line Item Explanation


Log type: <Log type> Specifies the type of hardware log, for example:
Log type: Embedded Server
Management (ESM)
Memory device bank Specifies the name of the memory bank in the
location: system that generated the message, for
<Bank name in chassis> example:
Memory device bank location:
Bank_1
Memory device location: Specifies the location of the memory module
<Device name in in the chassis, for example:
chassis> Memory device location: DIMM_A
Number of devices Specifies the number of power supply or
required for full cooling devices required to achieve full
redundancy: <Number> redundancy, for example:
Number of devices required for
full redundancy: 4
Peak value (in Watts): Specifies the peak value in Watts, for example:
<Reading> Peak value (in Watts): 125
Possible memory module Specifies a list of possible causes for the
event cause: <list of memory module event, for example:
causes>
Possible memory module event
cause: Single bit warning
error rate exceeded
Single bit error logging
disabled
Power Supply type: Specifies the type of power supply, for example:
<type of power supply>
Power Supply type: VRM
Pre-failure state was: Specifies the status of the previous memory
<State> message, for example:
Pre-failure state was: Failed

714 Traps
book.book Page 715 Monday, March 14, 2011 3:01 PM

Table 27-1. Trap Description Reference (continued)

Description Line Item Explanation


Previous redundancy Specifies the status of the previous redundancy
state was: <State> message, for example:
Previous redundancy state was:
Lost
Previous state was: Specifies the previous state of the sensor, for
<State> example:
Previous state was: OK (Normal)
Processor sensor Specifies the status of the processor sensor, for
status: example:
<status> Processor sensor status:
Configuration error
Redundancy unit: Specifies the location of the redundant power
<Redundancy location in supply or cooling unit in the chassis, for
chassis> example:
Redundancy unit: Fan Enclosure
SD card device type: Specifies the type of SD card device, for
<Type of SD card example:
device> SD card device type: Hypervisor

SD card state: Specifies the state of the SD card, for example:


<State of SD card> SD card state: Present, Failed
Sensor location: Specifies the location of the sensor in the
<Location in chassis> specified chassis, for example:
Sensor location: CPU1
Temperature sensor Specifies the temperature in degrees Celsius,
value (in degrees for example:
Celsius): Temperature sensor value (in
<Reading> degrees Celsius): 30
Voltage sensor value Specifies the voltage sensor value in volts, for
(in Volts): example:
<Reading> Voltage sensor value: 1.693

Traps 715
book.book Page 716 Monday, March 14, 2011 3:01 PM

Understanding Trap Severity


Traps often contain information about values recorded by probes or sensors.
Probes and sensors monitor critical components for values such as amperage,
voltage, and temperature. When an event occurs on your system, the Server
Administrator sends information about one of the following event types to
the system management console:
• Information/Informational—An event that describes the successful
operation of a unit, such as a power supply turning on or a sensor reading
returning to normal.
• Warning — An event that is not necessarily significant, but may indicate a
possible future problem, such as crossing a warning threshold.
• Critical/Error — A significant event that indicates actual or imminent loss
of data or loss of function, such as crossing a failure threshold or a
hardware failure.

Instrumentation Traps
This section describes the traps that are generated by the Instrumentation
service of the Server Administrator. All of the traps documented in this
section belong to the MIB enterprise identified by OID
1.3.6.1.4.1.674.10892.1 and are sent with all of the trap variables documented
in the section, "Trap Variables" on page 710. The trap variables are sent in the
order in which they are listed. The messages in the Description fields below
show the format of the message that is sent in the alertMessage varbind. If a
message in a Description field has multiple lines, the message contains
newline (0Ah) characters that are part of the value in the alertMessage
varbind.

Miscellaneous Traps
Table 27-2 lists Miscellaneous traps that inform you that certain alert systems
are up and working.

716 Traps
book.book Page 717 Monday, March 14, 2011 3:01 PM

Table 27-2. Miscellaneous Traps

Trap Description Severity Cause


ID
System Up
1001 Server Information Server Administrator completed its
Administrator initialization.
startup complete
Thermal Shutdown
1004 Thermal shutdown Error This message is generated when a
protection has system is configured for thermal
been initiated shutdown due to an error event. If a
temperature sensor reading exceeds
the error threshold for which the
system is configured, the operating
system shuts down and the system
powers off. This event may also be
initiated on certain systems when a fan
enclosure is removed from the system
for an extended period of time.
Automatic System Recovery
1006 Automatic System Error This message is generated when an
Recovery (ASR) automatic system recovery action is
action was performed due to a hung operating
performed system. The action performed and
Action performed the date and time of the action are
was: <Action> provided.

Date and time of


action: <Date and
time>
Host System Reset
1007 User initiated Information User requested a host system control
host system action to reboot, power off, or power
control action cycle the system or another event
Action requested such as thermal shutdown protection
was: <Action> initiated a power off, operating
system shutdown.

Traps 717
book.book Page 718 Monday, March 14, 2011 3:01 PM

Table 27-2. Miscellaneous Traps (continued)

Trap Description Severity Cause


ID
System Peak Power New Peak
1013 System Peak Power Information This message is generated when the
detected new peak system peak power sensor has
value detected a new peak value.
Peak value (in
Watts): <Reading>
System Software Event
1014 System software Minor This message is generated when a
event has occured. system software event occurs. The
Description: description of the event and the date
<Description of and time of the event are provided.
event>
Date and time of
action: <Date and
time>

Temperature Probe Traps


Temperature probes help protect critical components by alerting the systems
management console when temperatures become too high inside a chassis.
The temperature probe traps use additional variables: sensor location, chassis
location, previous state, and temperature sensor value reported in degrees
Celsius.

718 Traps
book.book Page 719 Monday, March 14, 2011 3:01 PM

Table 27-3. Temperature Probe Traps

Trap ID Description Severity Cause


Temperature Probe Normal
1052 Temperature sensor returned Information A temperature sensor
to a normal value on the backplane
Sensor location: board, system board,
<Location in chassis> or drive carrier in the
specified system
Chassis location: returned to a valid
<Name of chassis> range after crossing a
Previous state was: <State> failure threshold.
The sensor location,
If sensor type is not
chassis location,
discrete:
previous state, and
Temperature sensor value (in
temperature sensor
degrees Celsius): <Reading>
value are provided.
If sensor type is discrete:
Discrete temperature state:
<State>
Temperature Probe Warning
1053 Temperature sensor detected Warning A temperature sensor
a warning value on the backplane
Sensor location: board, system board,
<Location in chassis> or drive carrier in the
specified system
Chassis location: exceeded its warning
<Name of chassis> threshold. The sensor
Previous state was: <State> location, chassis
location, previous
If sensor type is not
state, and
discrete:
temperature sensor
Temperature sensor value (in
value are provided.
degrees Celsius): <Reading>
If sensor type is discrete:
Discrete temperature state:
<State>

Traps 719
book.book Page 720 Monday, March 14, 2011 3:01 PM

Table 27-3. Temperature Probe Traps (continued)

Trap ID Description Severity Cause


Temperature Probe Failure
1054 Temperature sensor detected Error A temperature sensor
a failure value on the backplane
Sensor location: board, system board,
<Location in chassis> or drive carrier in the
specified system
Chassis location: <Name of exceeded its failure
chassis> threshold. The sensor
Previous state was: <State> location, chassis
location, previous
If sensor type is not
state, and
discrete:
temperature sensor
Temperature sensor value (in
value are provided.
degrees Celsius): <Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Temperature Probe Nonrecoverable
1055 Temperature sensor detected Error A temperature sensor
a non-recoverable value on the backplane
Sensor location: board, system board,
<Location in chassis> or drive carrier in the
specified system
Chassis location: <Name of detected an error
chassis> from which it cannot
Previous state was: <State> recover. The sensor
location, chassis
If sensor type is not
location, previous
discrete:
state, and
Temperature sensor value (in
temperature sensor
degrees Celsius): <Reading>
value are provided.
If sensor type is discrete:
Discrete temperature state:
<State>

720 Traps
book.book Page 721 Monday, March 14, 2011 3:01 PM

Cooling Device Traps


Cooling device traps monitor how well a fan is functioning.

Table 27-4. Cooling Device Traps

Trap ID Description Severity Cause


Cooling Device Normal
1102 Fan sensor returned to a Information A fan sensor reading
normal value on the specified
Sensor location: system returned to a
<Location in chassis> valid range after
crossing a warning
Chassis location: <Name of threshold. The
chassis> sensor location,
Previous state was: <State> chassis location,
previous state, and
Fan sensor value: <Reading>
fan sensor value are
provided.
Cooling Device Warning
1103 Fan sensor detected a Warning A fan sensor reading
warning value in the specified
Sensor location: system exceeded a
<Location in chassis> warning threshold.
The sensor location,
Chassis location: <Name of chassis location,
chassis> previous state, and
Previous state was: <State> fan sensor value are
provided.
Fan sensor value: <Reading>

Traps 721
book.book Page 722 Monday, March 14, 2011 3:01 PM

Table 27-4. Cooling Device Traps (continued)

Trap ID Description Severity Cause


Cooling Device Failure
1104 Fan sensor detected a Error A fan sensor in the
failure value specified system
Sensor location: detected the failure
<Location in chassis> of one or more fans.
The sensor location,
Chassis location: <Name of chassis location,
chassis> previous state, and
Previous state was: <State> fan sensor value are
provided.
Fan sensor value: <Reading>
Cooling Device Nonrecoverable
1105 Fan sensor detected a Error A fan sensor detected
non-recoverable value an error from which
Sensor location: it cannot recover.
<Location in chassis> The sensor location,
chassis location,
Chassis location: <Name of previous state, and
chassis> fan sensor value are
Previous state was: <State> provided.
Fan sensor value: <Reading>

722 Traps
book.book Page 723 Monday, March 14, 2011 3:01 PM

Voltage Probe Traps


Voltage probes monitor the number of volts across critical components.

Table 27-5. Voltage Probe Traps

Trap ID Description Severity Cause


Voltage Probe Normal
1152 Voltage sensor returned to Information A voltage sensor in the
a normal value specified system
Sensor location: returned to a valid range
<Location in chassis> after crossing a failure
threshold. The sensor
Chassis location: <Name of location, chassis
chassis> location, previous state,
Previous state was: <State> and voltage sensor value
are provided.
If sensor type is not
discrete:
Voltage sensor value (in
Volts): <Reading>
If sensor type is discrete:
Discrete voltage state:
<State>
Voltage Probe Warning
1153 Voltage sensor detected a Warning A voltage sensor in the
warning value specified system
Sensor location: exceeded its warning
<Location in chassis> threshold. The sensor
location, chassis
Chassis location: <Name of location, previous state,
chassis> and voltage sensor value
Previous state was: <State> are provided.
If sensor type is not
discrete:
Voltage sensor value (in
Volts): <Reading>
If sensor type is discrete:
Discrete voltage state:
<State>

Traps 723
book.book Page 724 Monday, March 14, 2011 3:01 PM

Table 27-5. Voltage Probe Traps (continued)

Trap ID Description Severity Cause


Voltage Probe Failure
1154 Voltage sensor detected a Error A voltage sensor in the
failure value specified system
Sensor location: exceeded its failure
<Location in chassis> threshold. The sensor
location, chassis
Chassis location: <Name of location, previous state,
chassis> and voltage sensor value
Previous state was: <State> are provided.
If sensor type is not
discrete:
Voltage sensor value (in
Volts): <Reading>
If sensor type is discrete:
Discrete voltage state:
<State>
Voltage Probe Nonrecoverable
1155 Voltage sensor detected a Error A voltage sensor in the
non-recoverable value specified system
Sensor location: detected an error from
<Location in chassis> which it cannot recover.
The sensor location,
Chassis location: <Name of chassis location,
chassis> previous state, and
Previous state was: <State> voltage sensor value are
provided.
If sensor type is not
discrete:
Voltage sensor value (in
Volts): <Reading>
If sensor type is discrete:
Discrete voltage state:
<State>

724 Traps
book.book Page 725 Monday, March 14, 2011 3:01 PM

Amperage Probe Traps


Amperage probes measure the amount of current (in amperes) that is
traversing critical components.

Table 27-6. Amperage Probe Traps

Trap ID Description Severity Cause


Amperage Probe Normal
1202 Current sensor returned to Information A current sensor on the
a normal value power supply for the
Sensor location: specified system
<Location in chassis> returned to a valid range
after crossing a failure
Chassis location: <Name of threshold. The sensor
chassis> location, chassis
Previous state was: <State> location, previous state,
and current sensor value
If sensor type is not
are provided.
discrete: Current sensor
value (in Amps): <Reading>
If sensor type is discrete:
Discrete current state:
<State>
Amperage Probe Warning
1203 Current sensor detected a Warning A current sensor on the
warning value power supply for the
Sensor location: specified system
<Location in chassis> exceeded its warning
threshold. The sensor
Chassis location: <Name of location, chassis
chassis> location, previous state,
Previous state was: <State> and current sensor value
are provided.
If sensor type is not
discrete: Current sensor
value (in Amps): <Reading>
If sensor type is discrete:
Discrete current state:
<State>

Traps 725
book.book Page 726 Monday, March 14, 2011 3:01 PM

Table 27-6. Amperage Probe Traps (continued)

Trap ID Description Severity Cause


Amperage Probe Failure
1204 Current sensor detected a Error A current sensor on the
failure value power supply for the
Sensor location: <Location specified system
in chassis> exceeded its failure
threshold. The sensor
Chassis location: <Name of location, chassis
chassis> location, previous state,
Previous state was: <State> and current sensor value
are provided.
If sensor type is not
discrete: Current sensor
value (in Amps): <Reading>
If sensor type is discrete:
Discrete current state:
<State>
Amperage Probe Nonrecoverable
1205 Current sensor detected a Error A current sensor in the
non-recoverable value specified system
Sensor location: detected an error from
<Location in chassis> which it cannot recover.
The sensor location,
Chassis location: <Name of chassis location, previous
chassis> state, and current sensor
Previous state was: <State> value are provided.
If sensor type is not
discrete: Current sensor
value (in Amps): <Reading>
If sensor type is discrete:
Discrete current state:
<State>

726 Traps
book.book Page 727 Monday, March 14, 2011 3:01 PM

Chassis Intrusion Traps


Chassis intrusion traps are a security measure. Chassis intrusion means that
someone is opening the cover to a system’s chassis. Alerts are sent to prevent
unauthorized removal of parts from a chassis.

Table 27-7. Chassis Intrusion Traps

Trap ID Description Severity Cause


Chassis Intrusion Normal
1252 Chassis intrusion returned Information A chassis intrusion
to normal sensor in the specified
Sensor location: system detected that a
<Location in chassis> cover was opened while
the system was
Chassis location: <Name of operating but has since
chassis> been replaced. The
Previous state was: sensor location, chassis
<State> location, previous state,
and chassis intrusion
Chassis intrusion state:
state are provided.
<Intrusion state>
Chassis Intrusion Detected
1254 Chassis intrusion detected Error A chassis intrusion
Sensor location: sensor in the specified
<Location in chassis> system detected that
the system cover was
Chassis location: <Name of opened while the
chassis> system was operating.
Previous state was: The sensor location,
<State> chassis location,
previous state, and
Chassis intrusion state:
chassis intrusion state
<Intrusion state>
are provided.

Traps 727
book.book Page 728 Monday, March 14, 2011 3:01 PM

Redundancy Unit Traps


Redundancy means that a system chassis has more than one of certain critical
components. Fans and power supplies, for example, are so important for
preventing damage or disruption of a computer system that a chassis may
have extra fans or power supplies installed. Redundancy allows a second or
nth fan to keep the chassis components at a safe temperature when the
primary fan has failed. Redundancy is normal when the intended number of
critical components are operating. Redundancy is degraded when a
component fails but others are still operating. Redundancy is lost when the
number of components functioning falls below the redundancy threshold.
The number of devices required for full redundancy is provided as part of the
trap message when applicable for the redundancy unit and the platform. For
more details on redundancy computation, please refer to the respective
platform documentation.

Table 27-8. Redundancy Unit Traps

Trap ID Description Severity Cause


Redundancy Normal
1304 Redundancy regained Information A redundancy sensor in the
Redundancy unit: specified system detected
<Redundancy location in that a lost redundancy
chassis> device has been reconnected
or replaced; full redundancy
Chassis location: is in effect. The redundancy
<Name of chassis> unit location, chassis
Previous redundancy location, and previous
state was: <State> redundancy state are
provided.
Number of devices
required for full
redundancy: <Number>

728 Traps
book.book Page 729 Monday, March 14, 2011 3:01 PM

Table 27-8. Redundancy Unit Traps (continued)

Trap ID Description Severity Cause


Redundancy Degraded
1305 Redundancy degraded Warning A redundancy sensor in the
Redundancy unit: specified system detected
<Redundancy location in that one of the components
chassis> of the redundancy unit has
failed but the unit is still
Chassis location: redundant. The redundancy
<Name of chassis> unit location, chassis
Previous redundancy location, and previous
state was: <State> redundancy state are
provided.
Number of devices
required for full
redundancy: <Number>
Redundancy Lost
1306 Redundancy lost Warning or A redundancy sensor in the
Redundancy unit: Error specified system detected
<Redundancy location in (depending that one of the components
chassis> on the in the redundant unit has
number of been disconnected, has
Chassis location: units that failed, or is not present. The
<Name of chassis> are redundancy unit location,
Previous redundancy functional) chassis location, and
state was: <State> previous redundancy state
are provided.
Number of devices
required for full
redundancy: <Number>

Traps 729
book.book Page 730 Monday, March 14, 2011 3:01 PM

Power Supply Traps


Power supply traps provide status and warning information for power supplies
present in a particular chassis.

Table 27-9. Power Supply Traps

Trap ID Description Severity Cause


Power Supply Normal
1352 Power supply returned Information A power supply has been
to normal reconnected or replaced.
Sensor location: The sensor location, chassis
<Location in chassis> location, previous state, and
additional information
Chassis location: about the power supply
<Name of chassis> event are provided.
Previous state was:
<State>
Power Supply type:
<type of power supply>
<Additional power
supply status
information>
If in configuration
error state:
Configuration error
type: <type of
configuration error>

730 Traps
book.book Page 731 Monday, March 14, 2011 3:01 PM

Table 27-9. Power Supply Traps (continued)

Trap ID Description Severity Cause


Power Supply Warning
1353 Power supply detected a Warning A power supply sensor has
warning detected a warning
Sensor location: condition. The sensor
<Location in chassis> location, chassis location,
previous state, and
Chassis location: additional power supply
<Name of chassis> status information are
Previous state was: provided.
<State>
Power Supply type:
<type of power supply>
<Additional power
supply status
information>
If in configuration
error state:
Configuration error
type: <type of
configuration error>

Traps 731
book.book Page 732 Monday, March 14, 2011 3:01 PM

Table 27-9. Power Supply Traps (continued)

Trap ID Description Severity Cause


Power Supply Failure
1354 Power supply detected a Error A power supply has been
failure disconnected or has failed.
Sensor location: The sensor location, chassis
<Location in chassis> location, previous state, and
additional information
Chassis location: about the power supply
<Name of chassis> event are provided.
Previous state was:
<State>
Power Supply type:
<type of power supply>
<Additional power
supply status
information>
If in configuration
error state:
Configuration error
type: <type of
configuration error>

Memory Device Traps


Memory device messages provide status and warning information for memory
modules present in a particular system. Memory devices determine health
status by counting the number of ECC memory corrections.
NOTE: A value of failure or non-recoverable does not indicate a system
failure or loss of data, but rather that the specified system exceeded the specified
ECC correction threshold. Although the system continues to function, you should
perform system maintenance as described in Table 27-10.

732 Traps
book.book Page 733 Monday, March 14, 2011 3:01 PM

Table 27-10. Memory Device Messages

Trap ID Description Severity Cause


1403 Memory device status is Warning A memory device correction
<status> rate exceeded an acceptable
Memory device location: value. The memory device
<Location in chassis> status and location are
provided.
Possible memory module
event cause: <list of
causes>
1404 Memory device status is Error A memory device correction
<Status> rate exceeded an acceptable
Memory device location: value, a memory spare bank
<Location in chassis> was activated, or a
Uncorrectable Memory
Possible memory module Event occurred. The system
event cause: <list of continues to function
causes> normally (except for a
Uncorrectable Memory
Event). Clear the memory
error on Uncorrectable
Memory Event. Replace the
memory module identified
in the message during the
system’s next scheduled
maintenance. The memory
device status and location
are provided.

Fan Enclosure Traps


Some systems are equipped with a protective enclosure for fans. Fan
enclosure traps monitor enclosures for whether foreign objects are present
and for how long a fan enclosure is absent from a chassis.

Traps 733
book.book Page 734 Monday, March 14, 2011 3:01 PM

Table 27-11. Fan Enclosure Traps

Trap Description Severity Cause


ID
Fan Enclosure Insertion
1452 Fan enclosure inserted Information A fan enclosure has been
into system inserted into the specified
Sensor location: system. The sensor
<Location in chassis> location and chassis
location are provided.
Chassis location:
<Name of chassis>
Fan Enclosure Removal
1453 Fan enclosure removed Warning A fan enclosure has been
from system removed from the specified
Sensor location: system. The sensor
<Location in chassis> location and chassis
location are provided.
Chassis location:
<Name of chassis>
Fan Enclosure Extended Removal
1454 Fan enclosure removed Error A fan enclosure has been
from system for an removed from the specified
extended amount of system for a user-definable
time length of time. The sensor
Sensor location: location and chassis
<Location in chassis> location are provided.

Chassis location:
<Name of chassis>

AC Power Cord Traps


The AC power cord sensor monitors the presence of AC power for an
AC power cord. AC power cord traps provide status and warning information
for power cords that are part of an AC power switch, if your system supports
AC switching.

734 Traps
book.book Page 735 Monday, March 14, 2011 3:01 PM

Table 27-12. AC Power Cord Traps

Trap ID Description Severity Cause


AC Power Cord No Power Nonredundant
1501 AC power cord is not Information The AC power cord status is
being monitored not being monitored. This
Sensor location: occurs when a system’s
<Location in chassis> expected AC power
configuration is set to
Chassis location: nonredundant. The sensor
<Name of chassis> location and chassis location
information are provided.
AC Power Cord Normal
1502 AC power has been Information An AC power cord that did
restored not have AC power has had
Sensor location: the power restored. The
<Location in chassis> sensor location and chassis
location information are
Chassis location: provided.
<Name of chassis>
AC Power Cord Failure
1504 AC power has been lost Error An AC power cord has lost
Sensor location: its power. The sensor
<Location in chassis> location and chassis location
information are provided.
Chassis location:
<Name of chassis>

Hardware Log Traps


Hardware logs provide hardware status messages to systems management
software. On certain systems, the hardware log is implemented as a circular
queue. When the log becomes full, the oldest status messages are overwritten
when new status messages are logged. On some systems, the log is not
circular. When the log becomes full, subsequent hardware status messages are
lost. Hardware log sensor messages provide status and warning information
about the noncircular logs that may fill up, resulting in lost status messages.

Traps 735
book.book Page 736 Monday, March 14, 2011 3:01 PM

Table 27-13. Hardware Log Traps

Trap ID Description Severity Cause


Hardware Log Normal
1552 Log size is no longer Information The hardware log on the
near or at capacity specified system is no
Log type: <Log type> longer near or at its
capacity, usually as the
result of clearing the log.
The log type information is
provided.
Hardware Log Warning
1553 Log size is near or at Warning The size of a hardware log
capacity on the specified system is
Log type: <Log type> near or at the capacity of
the hardware log. The log
type information is
provided.
Hardware Log Full
1554 Log size is full Error The size of a hardware log
Log type: <Log type> on the specified system is at
the capacity of the
hardware log. The log type
information is provided.

Processor Device Status Traps


The BMC on some systems reports the status of processor devices. Processor
device status traps provide status and warning information for processor devices
present in a system with a BMC that reports the status of processor devices.

736 Traps
book.book Page 737 Monday, March 14, 2011 3:01 PM

Table 27-14. Processor Device Status Traps

Trap ID Description Severity Cause


Processor Device Status Normal
1602 Processor sensor Information A processor sensor in the
returned to a normal specified system
value transitioned back to a
Sensor Location: normal state. The sensor
<Location in chassis> location, chassis location,
previous state and processor
Chassis Location: <Name sensor status are provided.
of chassis>
Previous state was:
<State>
Processor sensor
status: <status>
Processor Device Status Warning
1603 Processor sensor Warning A processor sensor in the
detected a warning specified system is in a
value throttled state. The sensor
Sensor Location: location, chassis location,
<Location in chassis> previous state and processor
sensor status are provided.
Chassis Location: <Name
of chassis>
Previous state was:
<State>
Processor sensor
status: <status>

Traps 737
book.book Page 738 Monday, March 14, 2011 3:01 PM

Table 27-14. Processor Device Status Traps (continued)

Trap ID Description Severity Cause


Processor Device Status Failure
1604 Processor sensor Error A processor sensor in the
detected a failure specified system is disabled,
value has a configuration error, or
Sensor Location: experienced a thermal trip.
<Location in chassis> The sensor location, chassis
location, previous state and
Chassis Location: <Name processor sensor status are
of chassis> provided.
Previous state was:
<State>
Processor sensor
status: <status>

Pluggable Device Traps


Server Administrator monitors the addition and removal of pluggable devices
such as memory cards. Device traps provide information about the addition
and removal of such devices.

Table 27-15. Pluggable Device Traps

Trap ID Description Severity Cause


Pluggable Device Addition
1651 Device added to system Information A device was added to the
Device Location: specified system. The
<Location in chassis> device location, chassis
location, and additional
Chassis Location: <Name event details, if available,
of chassis> are provided.
Additional Details:
<Additional details for
the events>

738 Traps
book.book Page 739 Monday, March 14, 2011 3:01 PM

Table 27-15. Pluggable Device Traps (continued)

Trap ID Description Severity Cause


Pluggable Device Removal
1652 Device removed from system
Information A device was removed from
Device Location: the specified system. The
<Location in chassis> device location, chassis
location, and additional
Chassis Location: <Name event details, if available,
of chassis> are provided.
Additional Details:
<Additional details for
the events>
Pluggable Device Configuration Error
1653 Device configuration error Error A configuration error was
detected detected for a pluggable
Device Location: device in the specified
<Location in chassis> system. The device may
have been added to the
Chassis Location: <Name system incorrectly. The
of chassis> device location, chassis
Additional Details: <Additional location, and additional
details for the events> event details, if available,
are provided.

Battery Traps
The BMC on some systems reports the status of batteries. Battery traps
provide status and warning information for batteries present in a system with
a BMC that reports the status of batteries.

Traps 739
book.book Page 740 Monday, March 14, 2011 3:01 PM

Table 27-16. Battery Traps

Trap ID Description Severity Cause


Battery Normal
1702 Battery sensor returned Information A battery sensor in the
to a normal value specified system detected
Sensor Location: that a battery transitioned
<Location in chassis> back to a normal state.
The sensor location,
Chassis Location: <Name chassis location, previous
of chassis> state, and battery sensor
Previous state was: status are provided.
<State>
Battery sensor status:
<status>
Battery Warning
1703 Battery sensor detected Warning A battery sensor in the
a warning value specified system detected
Sensor Location: that a battery is in a
<Location in chassis> predictive failure state.
The sensor location,
Chassis Location: <Name chassis location, previous
of chassis> state, and battery sensor
Previous state was: status are provided.
<State>
Battery sensor status:
<status>

740 Traps
book.book Page 741 Monday, March 14, 2011 3:01 PM

Table 27-16. Battery Traps (continued)

Trap ID Description Severity Cause


Battery Failure
1704 Battery sensor detected Critical A battery sensor in the
a failure value specified system detected
Sensor Location: that a battery has failed.
<Location in chassis> The sensor location,
chassis location, previous
Chassis Location: <Name state, and battery sensor
of chassis> status are provided.
Previous state was:
<State>
Battery sensor status:
<status>

SD Card Device Traps


On systems where the BMC reports the status of SD card devices, the SD
card device traps provide status and error information.

Table 27-17. SD Card Device Traps

Trap ID Description Severity Cause


SD Card Device Failure
1754 SD card device detected Critical An SD card device sensor
a failure in the specified system
Sensor Location: detected an error. The
<Location in chassis> sensor location, chassis
location, previous state
Chassis Location: <Name and SD card device type
of chassis> are provided. The SD card
Previous state was: state is provided if a SD
<State> card is present in the SD
card device.
SD card device type:
<Type of SD card
device>
SD card state: <State
of SD card>

Traps 741
book.book Page 742 Monday, March 14, 2011 3:01 PM

RAC Traps
This section describes the traps that are generated by the SNMP agent of the
Remote Access Controller (RAC). All of the enterprise-specific traps documented
in this section belong to the MIB enterprise identified by OID
1.3.6.1.4.1.674.10892.2 and are sent with all of the trap variables documented in
the section "Traps" on page 709. The trap variables are sent in the order in which
they are listed.

Table 27-18. Generic Traps

Trap Name Description Severity Category Cause Supported


ID by RAC
Platform
0 CodeStart SNMP agent Information Status RAC power All
is on or reset.
initializing
itself
1 Authentic Request Critical Error SNMP All
ation received request
Failure with an with an
invalid invalid
community community
name name.

Table 27-19. Enterprise-specific Traps

Trap Name Description Severity Category Cause Supported


ID by RAC
Platform
1001 alertDrscTest The RAC Information Status A test SNMP All
TrapEvent generated trap
a test generated by
trap event a RAC.
in
response
to a user
request

742 Traps
book.book Page 743 Monday, March 14, 2011 3:01 PM

Table 27-19. Enterprise-specific Traps (continued)

Trap Name Description Severity Category Cause Supported


ID by RAC
Platform
1002 alertDrscAuth RAC Minor Error RAC login All
Error Authentica failure caused
tion by
failures authenticatio
during a n failure,
time number of
period concurrent
have logins exceed
exceeded a limit, or
threshold permission
denied.
1003 alertDrscLost The RAC Critical Error RAC lost Dell
ESM cannot communicati Remote
communicate on with ESM. Access
with the Controller
baseboard (DRAC) III
management
controller
(ESM)
1004 alertDrscFound The RAC is Information Error RAC DRAC III
ESM communicat recovered
ing communicati
normally on with ESM.
with the
baseboard
management
controller
(ESM)

Traps 743
book.book Page 744 Monday, March 14, 2011 3:01 PM

Table 27-19. Enterprise-specific Traps (continued)

Trap Name Description Severity Category Cause Supported


ID by RAC
Platform
1005 alertDrscPower The RAC Critical Error RAC DRAC III
Off has detected a
detected a system power
system state change
power to power-off.
state
change to
powered-
off
1006 alertDrscPower The RAC Information Error RAC DRAC III
On has detected a
detected a system power
system state change
power to power-on.
state
change to
powered-on
1007 alertDrsc The RAC Critical Event RAC has DRAC III
Watchdog has detected the
Expired detected system
that the watchdog
system expired
watchdog (normally
has indicating a
expired system hang).
indicating
a system
hang

744 Traps
book.book Page 745 Monday, March 14, 2011 3:01 PM

Table 27-19. Enterprise-specific Traps (continued)

Trap Name Description Severity Category Cause Supported


ID by RAC
Platform
1008 alertDrscBatt The RAC Minor Error RAC DRAC III
Low Battery detected its
charge is battery
below 25% charge is
indicating below 25%
that the full.
battery
may only
be able to
power the
DRSC for
8-10
minutes
1009 alertDrscTemp The RAC Information Status RAC DRAC III
Normal Temperature temperature
probe has probe reading
returned returned to
to a normal.
normal
value
1010 alertDrscTemp The RAC Minor Status RAC DRAC III
Warning Temperature temperature
probe has probe reading
detected a exceeded
Warning warning
value threshold.
1011 alertDrscTemp The RAC Critical Error RAC DRAC III
Critical Temperature temperature
probe has probe reading
detected a exceeded
failure critical
(or threshold.
critical)
value

Traps 745
book.book Page 746 Monday, March 14, 2011 3:01 PM

Table 27-19. Enterprise-specific Traps (continued)

Trap Name Description Severity Category Cause Supported


ID by RAC
Platform
1012 alertDrscVolt The RAC Information Error RAC voltage DRAC III
Normal voltage probe reading
has returns to
returned normal.
to a
normal
value
1013 alertDrscVolt The RAC Minor Error RAC voltage DRAC III
Warning voltage probe reading
probe has exceeded
detected a warning
warning threshold.
value
1014 alertDrscVolt The RAC Critical Error RAC voltage DRAC III
Critical voltage probe reading
probe has exceeded
detected a critical
failure threshold.
(or
critical)
value
1015 alertDrscSEL The RAC Major Error RAC All
Warning has detected a
detected a new system
new event event log with
in the warning
System severity
Event Log (detailed log
with info is in
Severity: drsAlert
Warning Message
varbind).

746 Traps
book.book Page 747 Monday, March 14, 2011 3:01 PM

Table 27-19. Enterprise-specific Traps (continued)

Trap Name Description Severity Category Cause Supported


ID by RAC
Platform
1016 alertDrscSEL The RAC Critical Error RAC All
Critical has detected a
detected a new system
new event event log with
in the critical
System severity
Event Log (detailed log
with info is in
Severity: drsAlert
Critical Message
varbind).
1017 alertDrscSEL The RAC Major Status RAC All
80 system detected
percentFull event log system event
is 80% log is 80%
full full.
1018 alertDrscSEL The RAC Major Status RAC All
90 system detected
percentFull event log system event
is 90% log is 90%
full full.
1019 alertDrscSEL The RAC Major Status RAC All
100 system detected
percentFull event log system event
is 100% log is 100%
full full.

Traps 747
book.book Page 748 Monday, March 14, 2011 3:01 PM

Table 27-19. Enterprise-specific Traps (continued)

Trap Name Description Severity Category Cause Supported


ID by RAC
Platform
1020 alertDrscSEL The RAC Information Error RAC All
Normal has detected a
detected a new system
new event event log with
in the normal
System severity
Event Log (detailed log
with info is in
Severity: drsAlert
Normal Message
varbind).

BMC Traps
The BMC monitors the system for critical events by communicating with
various sensors on the system board and by sending alerts and log events
when certain parameters exceed their preset thresholds. All of the traps
documented in this section belong to the MIB enterprise identified by OID
1.3.6.1.4.1.3183.1.1.1.

Table 27-20. BMC Traps

Trap ID Description Severity


262402 Generic Critical Fan Failure Critical
262530 Generic Critical Fan Failure Cleared Informational
131330 Under-Voltage Problem (Lower Critical - Critical
going low)
131458 Under-Voltage Problem Cleared Informational
131841 Generic Critical Voltage Problem Critical
131840 Generic Critical Voltage Problem Informational
Cleared
65792 Under-Temperature Warning (Lower non- Warning
critical, going low)

748 Traps
book.book Page 749 Monday, March 14, 2011 3:01 PM

Table 27-20. BMC Traps (continued)

Trap ID Description Severity


65920 Under-Temperature Warning Cleared Informational
65794 Under-Temperature Problem (Lower Critical
Critical - going low)
65922 Under-Temperature Problem Cleared Informational
65799 Over-Temperature warning (Upper non- Minor
critical, going high)
65927 Over-Temperature warning Cleared Informational
65801 Over-Temperature Problem (Upper Critical
Critical - going high)
65929 Over-Temperature Problem Cleared Informational
131328 Under-Voltage Warning (Lower Non Warning
Critical - going low)
131456 Under-Voltage Warning Cleared Informational
131330 Under-Voltage Problem (Lower Critical - Critical
going low)
131458 Under-Voltage Problem Cleared Informational
131335 Over-Voltage Warning (Upper Non Warning
Critical - going high)
131463 Over-Voltage Warning Cleared Informational
131337 Over-Voltage Problem (Upper Critical - Critical
going high)
131465 Over-Voltage Problem Cleared Informational
131841 Generic Critical Voltage Problem Critical
131840 Generic Critical Voltage Problem Informational
Cleared
356096 Chassis Intrusion - Physical Security Critical
Violation
356224 Chassis Intrusion (Physical Security Informational
Violation) Event Cleared

Traps 749
book.book Page 750 Monday, March 14, 2011 3:01 PM

Table 27-20. BMC Traps (continued)

Trap ID Description Severity


262400 Generic Predictive Fan Failure Minor
(predictive failure asserted)
262528 Generic Predictive Fan Failure Cleared Informational
262402 Generic Critical Fan Failure Critical
262530 Generic Critical Fan Failure Cleared Informational
264962 Fan redundancy has been degraded Warning
264961 Fan Redundancy Lost Critical
264960 Fan redundancy Has Returned to Normal Informational
2715392 Battery Low (Predictive Failure) Warning
2715520 Battery Low (Predictive Failure) Informational
Cleared
2715393 Battery Failure Critical
2715521 Battery Failure Cleared Informational
487169 CPU Thermal Trip (Over Temperature Critical
Shutdown)
487297 CPU Thermal Trip (Over Temperature Informational
Shutdown) Cleared
487168 CPU Internal Error Critical
487296 CPU Internal Error Cleared Informational
487173 CPU Configuration Error Critical
487301 CPU Configuration Error Cleared Informational
487175 CPU Presence (Processor Presence Informational
detected)
487303 CPU Not Present (Processor Not Present) Critical
487170 CPU BIST (Built In Self Test) Failure Critical
487298 CPU BIST (Built In Self Test) Failure Informational
Cleared
487176 CPU Disabled (Processor Disabled) Critical
487304 CPU Enabled (Processor Enabled) Informational

750 Traps
book.book Page 751 Monday, March 14, 2011 3:01 PM

Table 27-20. BMC Traps (continued)

Trap ID Description Severity


487178 CPU Throttle (Processor Speed Reduced) Warning
487306 CPU Throttle Cleared (Normal Processor Informational
Speed)
527106 Power Supply Redundancy Degraded Warning
527105 Power Supply Redundancy Lost Critical
527104 Power Supply Redundancy Has Returned to Informational
Normal
552704 Power Supply Inserted Informational
552832 Power Supply Removed Warning
552705 Power Supply Failure Critical
552833 Power Supply Failure Cleared Informational
552706 Power Supply Warning Warning
552834 Power Supply Warning Cleared Informational
552707 Power Supply AC Lost Critical
552835 Power Supply AC Restored Informational
789249 Memory Redundancy Has Been Lost Critical
789248 Memory redundancy Has Returned to Informational
Normal
1076994 System Event Log (SEL) Cleared Informational

Traps 751
book.book Page 752 Monday, March 14, 2011 3:01 PM

Table 27-20. BMC Traps (continued)

Trap ID Description Severity


1076996 System Event Log (SEL) Full (Logging Critical
Disabled)
2322176 ASR (Automatic System Recovery) Timer Critical
Expired
2322177 ASR (Automatic System Recovery) Reset Critical
Occurred
2322178 ASR (Automatic System Recovery) Power Critical
Down Occurred
2322179 ASR (Automatic System Recovery) Power Critical
Cycle Occurred

752 Traps
book.book Page 753 Monday, March 14, 2011 3:01 PM

Traps 753
book.book Page 754 Monday, March 14, 2011 3:01 PM

754 Traps
book.book Page 755 Monday, March 14, 2011 3:01 PM

28
Storage Management Alert
Reference
Storage Management’s alert or event management features let you monitor
the health of storage resources such as controllers, connectors, array disks,
and virtual disks.

Alert Monitoring and Logging


The Storage Management Service performs alert monitoring and logging.
By default, the Storage Management Service starts when the managed system
starts up. If you stop the Disk Management Service, then alert monitoring
and logging stops. Alert monitoring does the following:
• Updates the status of the storage object that generated the alert.
• Propagates the storage object’s status to all the related higher objects in
the storage hierarchy. For example, the status of a lower-level object are
propagated up to the status displayed on the Health tab for the top-level
storage object.
• Logs an alert into the Alert log and Microsoft Windows application log.
• Sends an Simple Network Management Protocol (SNMP) trap if the
operating system’s SNMP service is installed and enabled.
NOTE: Storage Management does not log alerts regarding the data I/O path. These
alerts are logged by the respective RAID drivers in the system alert log.

Storage Management Alert Reference 755


book.book Page 756 Monday, March 14, 2011 3:01 PM

Viewing Alerts
Storage Management generates alerts that are added to the Windows
application alert log and to the Server Administrator Alert log. To view these
alerts in Server Administrator:
1 Select the System object in the tree view.
2 Select the Logs tab.
3 Select the Alert subtab.
You can also view these alerts in the Windows Event Viewer. Every alert
consists of the following:
• Severity — Shows the severity of alert.
• Date and Time — Date and time when Storage Management logged the
alert.
• Description — A brief description of the alert. To expand or collapse the
alert description, click the Description column heading.

Alert Severity Levels


Each alert message in the Storage Management alert log has a severity level
which indicates the nature of the alert and is displayed in the Severity field of
the alert message. The severity level indicates the nature of the alert.

756 Storage Management Alert Reference


book.book Page 757 Monday, March 14, 2011 3:01 PM

The alert severity levels are as follows:

Table 28-1. Storage Management Alert Severity

Alert Severity Component Status


OK/Normal/Informational No action is required. The alert is provided for
informational purposes and does not indicate an error
condition. For example, the alert may indicate the
normal start or stop of an operation.
Warning/Non-critical A component requires attention. This alert indicates a
potential problem, but does not necessarily mean that
the system has currently lost data or is nonfunctional.
For example, a Warning/Non-critical alert may indicate
that a component (such as a temperature probe in an
enclosure) has crossed a warning threshold.
Critical/Failure/Error A component has either failed or failure is imminent.
This alert indicates a serious problem such as data loss or
a loss of function. For example, a Critical/Failure/Error
alert may indicate that an array disk has failed.

SNMP Support for Storage Management Alerts


By default, Storage Management installs SNMP trap forwarding support.
For this support to function, you should have SNMP installed on the
managed system prior to installing Storage Management.
NOTE: For more information on installation requirements and SNMP, see the
Server Administrator documentation.

SNMP Trap Forwarding


The Storage Management alerts are displayed in the Server Administrator
alert log and are forwarded to the Windows application alert log. If you have
SNMP installed on the managed system (and the SNMP service is running),
the Storage Management alerts in the Windows application alert log are
forwarded as SNMP traps. In order for these traps to be viewable, however,
a target system or application must be configured to receive these traps.
SNMP traps that are generated by Storage Management can be viewed in any
standard SNMP-compatible enterprise management console.

Storage Management Alert Reference 757


book.book Page 758 Monday, March 14, 2011 3:01 PM

The Windows SNMP service must be configured to forward the SNMP traps to
the target system or application. When forwarding to an application, the
application should also be configured to receive the SNMP traps. The IT
Assistant application is already configured to receive the SNMP traps
generated by Storage Management.
See your Windows operating system documentation for information on
configuring the operating system to forward SNMP traps. This information
may be located under such topics as “setting up SNMP” or “SNMP traps.”
When configuring SNMP for Windows, be sure that the SNMP traps are
forwarded to the correct server. For information on configuring an application
to receive SNMP traps, see the documentation for that application.

SNMP Trap Definitions


The Storage Management management information base (MIB) defines the
SNMP traps that Storage Management generates. These traps correspond to
the alerts documented in the "Alert Descriptions and Corrective Actions" on
page 759 section. The MIB is located in ..\sm\mibs\dcstorag.mib, a
subdirectory of the Storage Management installation directory.
NOTE: Storage Management supports trap forwarding on both 32-bit and 64-bit
operating systems.

SNMP Trap Variables


The Storage Management SNMP traps use a set of variables that are included
with every trap. These variables are the following:
• messageIDEvent
• descriptionEvent
• locationEvent
• objectNameEvent
• objectOIDEvent
• objectNexusEvent
• currentStatusEvent
• previousStatusEvent

758 Storage Management Alert Reference


book.book Page 759 Monday, March 14, 2011 3:01 PM

Viewing SNMP Traps


SNMP traps that are generated by Storage Management can be viewed in any
standard SNMP-compatible enterprise management console. These traps are
defined in the Storage Management MIB. These traps correspond to the
alerts documented in the “Alert Descriptions and Corrective Actions” section.
For more information on the MIB and its structure, as well as a change history
of the SNMP traps, see the "Introduction" on page 15 section. For more
information on configuring SNMP, see "SNMP Support for Storage
Management Alerts" on page 757.

Alert Descriptions and Corrective Actions


The alerts generated by the redundant array of independent disks (RAID) or
Small Computer System Interface (SCSI) controllers and supported by
Storage Management are displayed in the Server Administrator Alert subtab
or through Windows Event Viewer. These alerts can also be forwarded as
SNMP traps to other applications.
SNMP traps that are generated for the alerts are included in the Storage
Management MIB. The SNMP traps for these alerts use all of the SNMP trap
variables. For the list of storage management alerts and storage management
messages, see the Dell OpenManage Server Administrator Messages Reference
Guide available on the Dell Support website at support.dell.com/manuals.

Storage Management Alert Reference 759


book.book Page 760 Monday, March 14, 2011 3:01 PM

760 Storage Management Alert Reference


book.book Page 761 Monday, March 14, 2011 3:01 PM

29
Standard Data Type Definitions
This appendix contains definitions for data types that are standard in most
contexts across the information technology industry. These are the most
common data types for describing variable values defined in the 10892.mib,
dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable
values are defined in the last section of the section in which they are
introduced.

Common Data Types


Common data types include several types of strings, the object range, signed
and unsigned bit ranges, and the familiar Boolean (true or false) data type.

Table 29-1. Common Data Types

Variable Name: Definition


DellString DisplayString (SIZE (0..64))
DellSecurityString DisplayString (SIZE (0..255))
DellCostofOwnershipString DisplayString (SIZE (0..64))
DellObjectRange INTEGER (1..128)
DellUnsigned8BitRange INTEGER (1..256)
DellUnsigned16BitRange INTEGER (1..65535)
DellUnsigned32BitRange INTEGER (1..2147483647)
DellSigned32BitRange INTEGER (-2147483647..2147483647)
DellBoolean INTEGER (0..1 (FALSE = 0, TRUE = 1))

Standard Data Type Definitions 761


book.book Page 762 Monday, March 14, 2011 3:01 PM

Variables with Data Types of State Capabilities


and State Capabilities Unique
Variables with definitions of <variable name>StateCapabilities or
<variable name>StateCapabilitiesUnique are integers
representing a series of bit definitions. They are NOT enumerations and
should be treated as bit fields. The value is passed as a decimal value.
The decimal value should be converted to hex and the appropriate bits should
be parsed from hex. Some of the more common bit combinations are defined
in some variables, but not all combinations are or will be defined.

Table 29-2. Dell State Capabilities

Variable Name: DellStateCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
if set to zero(0) The object has no capabilities.
unknownCapabilities(1) The object’s capabilities are unknown.
enableCapable(2) The object can be disabled (offline, a
binary 0 value) or enabled (online, a
binary 1 value).
notReadyCapable(4) The object is not ready.
enableAndNotReadyCapable Enable and not ready capable.
(6)

762 Standard Data Type Definitions


book.book Page 763 Monday, March 14, 2011 3:01 PM

Table 29-3. Dell State Settings

Variable Name: DellStateSettings


Data Type: Integer
Possible Data Values Meaning of Data Value
if set to zero(0) The object has no settings capabilities and
its state is disabled.
unknown(1) The object’s state is unknown.
enabled(2) The object’s state is disabled (offline, a
binary 0 value) or enabled (online, a binary
1 value).
notReady(4) The object is not ready.
enableAndNotReady(6) The object is enabled and not ready.

Table 29-4. Dell Probe Capabilities

Variable Name: DellProbeCapabilities


Data Type: Integer
Possible Data Values Meaning of Data Value
if set to zero(0) The object has no capabilities.
upperNonCriticalThresholdSet The upper noncritical threshold
Capable(1) can be set.

lowerNonCriticalThresholdSet The lower noncritical threshold


Capable(2) can be set.

upperNonCriticalThresholdDef The upper noncritical threshold


aultCapable(4) can be set to default.

lowerNonCriticalThresholdDef The lower noncritical threshold


aultCapable(8) can be set to default.

Standard Data Type Definitions 763


book.book Page 764 Monday, March 14, 2011 3:01 PM

Dell Status Data Types


Status data types include DellStatus, DellStatusRedundancy, and
DellStatusProbe.

Table 29-5. Dell Status

Variable Name: DellStatus


Data Type: Integer
Possible Data Values Meaning of Data Value
other(1) The object’s status is not one of the following:
unknown(2) The object’s status is unknown.
ok(3) The object’s status is OK.
nonCritical(4) The object’s status is warning, noncritical.
critical(5) The object’s status is critical (failure).
nonRecoverable(6) The object’s status is nonrecoverable (dead).

Table 29-6. Dell Status Redundancy

Variable Name: DellStatusRedundancy


Data Type: Integer
Possible Data Values Meaning of Data Value
other(1) The object’s status is not one of the following:
unknown(2) The object’s redundancy status is unknown.
full(3) The object is fully redundant.
degraded(4) The object’s redundancy has been degraded.
lost(5) The object’s redundancy has been lost.
notRedundant(6) Redundancy does not apply or it is not redundant.

764 Standard Data Type Definitions


book.book Page 765 Monday, March 14, 2011 3:01 PM

Table 29-7. Dell Status Probe

Variable Name: DellStatusProbe


Data Type: Integer
Possible Data Values Meaning of Data Value
other(1) The object’s status is not one of the following:
unknown(2) The status of the object is unknown.
ok(3) The status of the object is OK.
nonCriticalUpper(4) The object is at the noncritical upper limit.
CriticalUpper(5) The object is at the critical upper limit.
nonRecoverableUpper(6) The object is at the nonrecoverable upper limit.
nonCriticalLower(7) The object is at the noncritical lower limit.
criticalLower(8) The object is at the critical lower limit.
nonRecoverableLower(9) The object is at the nonrecoverable lower limit.
failed(10) The status of the object is failed.

Dell Date
Variable Name: DellDate
Data Type: DellUnsigned64BitRange Octet String (SIZE(8))

The DellDate definition is required because SNMP V1 does not support 64-bit
ranges. The information sent back by this subagent has the most significant
byte of the information as the first byte. For example, the hex address
0x1029384754657687 is sent as hex: 0001 0000 0010 1001 0011 1000 0100
0111 ... Byte 1 Byte 2 Byte 3 Byte 4.

Standard Data Type Definitions 765


book.book Page 766 Monday, March 14, 2011 3:01 PM

Full Dates

Variable Name: DellDateName


Data Type: DisplayString DisplayString (SIZE (25))

Full dates are defined in the ASCII format:


yyyyMMddhhmmss.uuuuuu+fff or yyyyMMddhhmmss.uuuuuu-fff
where yyyy is the year, MM is the month, dd is the day, hh are the hours, mm
are the minutes, and ss are the seconds. uuuuuu is the number of
microseconds, and +fff or
-fff is the offset from UTC in minutes. For example, Friday, October 31, 2001,
at 6:05:19 PM CST would be represented as 20011031180519.000000-360.
The values are zero-padded, and if a valid value for a field is not deliverable,
each character in the field is replaced with an asterisk (*) character.

766 Standard Data Type Definitions


book.book Page 767 Monday, March 14, 2011 3:01 PM

30
SNMP Sample Output
This appendix contains the sample output from the Simple Network
Management Protocol (SNMP) covering the first four groups of the
Instrumentation management information base (MIB) sample output from
the Simple Network Management Protocol (SNMP) covers the first four
groups of the Instrumentation management information base (MIB). Values
are shown for each object identifier (OID) in the Instrumentation MIB
Version Group, the Systems Management Software Group, the System State
Group, the Chassis Information Table, and Event Log Table. The data is from
a Dell PowerEdge 2650 system.
Walk .1.3.6.1.4.1.674.10892 (Agent: 'SERVER01',
Community: 'public')

.iso.org.dod.internet.private.enterprises.dell.server3

1.3.6.1.4.1.674.10892.1.1.1.0 = 5
1.3.6.1.4.1.674.10892.1.1.2.0 = 3
1.3.6.1.4.1.674.10892.1.1.3.0 = 0
1.3.6.1.4.1.674.10892.1.100.1.0 = 'Server
Administrator'
1.3.6.1.4.1.674.10892.1.100.2.0 = '5.3.0'
1.3.6.1.4.1.674.10892.1.100.3.0 = 4522
1.3.6.1.4.1.674.10892.1.100.4.0 = 'Management
software for Dell systems.'
1.3.6.1.4.1.674.10892.1.100.5.0 = 1
1.3.6.1.4.1.674.10892.1.100.6.0 = 1
1.3.6.1.4.1.674.10892.1.100.7.0 = 'No Updates'

SNMP Sample Output 767


book.book Page 768 Monday, March 14, 2011 3:01 PM

1.3.6.1.4.1.674.10892.1.100.8.0 =
'https://1.2.3.4:1311'
1.3.6.1.4.1.674.10892.1.100.9.0 = 'en_US'
1.3.6.1.4.1.674.10892.1.100.10.0 = '2.2.0'
1.3.6.1.4.1.674.10892.1.100.11.0 = 0
1.3.6.1.4.1.674.10892.1.100.12.0 = 1
1.3.6.1.4.1.674.10892.1.100.13.0 = 'Dell Inc.'
1.3.6.1.4.1.674.10892.1.200.10.1.1.1 = 1
1.3.6.1.4.1.674.10892.1.200.10.1.2.1 = 3
1.3.6.1.4.1.674.10892.1.200.10.1.3.1 = 2
1.3.6.1.4.1.674.10892.1.200.10.1.4.1 = 3
1.3.6.1.4.1.674.10892.1.200.10.1.5.1 = '\02'
1.3.6.1.4.1.674.10892.1.200.10.1.6.1 = 3
1.3.6.1.4.1.674.10892.1.200.10.1.7.1 = '\03'
1.3.6.1.4.1.674.10892.1.200.10.1.8.1 = '\02\02'
1.3.6.1.4.1.674.10892.1.200.10.1.9.1 = 3
1.3.6.1.4.1.674.10892.1.200.10.1.10.1 = '\03\03'
1.3.6.1.4.1.674.10892.1.200.10.1.11.1 =
'\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\
02\02\02'
1.3.6.1.4.1.674.10892.1.200.10.1.12.1 = 3
1.3.6.1.4.1.674.10892.1.200.10.1.13.1 =
'\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\
03\03\03'
1.3.6.1.4.1.674.10892.1.200.10.1.20.1 =
'\02\02\02\02\02'
1.3.6.1.4.1.674.10892.1.200.10.1.21.1 = 3

768 SNMP Sample Output


book.book Page 769 Monday, March 14, 2011 3:01 PM

1.3.6.1.4.1.674.10892.1.200.10.1.22.1 =
'\03\03\03\03\03'
1.3.6.1.4.1.674.10892.1.200.10.1.23.1 =
'\02\02\02\02\02\02'
1.3.6.1.4.1.674.10892.1.200.10.1.24.1 = 3
1.3.6.1.4.1.674.10892.1.200.10.1.25.1 =
'\03\03\03\03\03\03'
1.3.6.1.4.1.674.10892.1.200.10.1.26.1 =
'\02\02\02\02'
1.3.6.1.4.1.674.10892.1.200.10.1.27.1 = 3
1.3.6.1.4.1.674.10892.1.200.10.1.28.1 =
'\03\03\03\03'
1.3.6.1.4.1.674.10892.1.200.10.1.29.1 = '\02'
1.3.6.1.4.1.674.10892.1.200.10.1.30.1 = 3
1.3.6.1.4.1.674.10892.1.200.10.1.31.1 = '\03'
1.3.6.1.4.1.674.10892.1.200.10.1.41.1 = 3
1.3.6.1.4.1.674.10892.1.200.10.1.42.1 = 3
1.3.6.1.4.1.674.10892.1.200.10.1.43.1 = '\03'
1.3.6.1.4.1.674.10892.1.300.10.1.1.1 = 1
1.3.6.1.4.1.674.10892.1.300.10.1.2.1 = 0
1.3.6.1.4.1.674.10892.1.300.10.1.3.1 = 2
1.3.6.1.4.1.674.10892.1.300.10.1.4.1 = 3
1.3.6.1.4.1.674.10892.1.300.10.1.5.1 = 0
1.3.6.1.4.1.674.10892.1.300.10.1.6.1 = 23
1.3.6.1.4.1.674.10892.1.300.10.1.7.1 = 'Main System
Chassis'
1.3.6.1.4.1.674.10892.1.300.10.1.8.1 = 'Dell Inc.'

SNMP Sample Output 769


book.book Page 770 Monday, March 14, 2011 3:01 PM

1.3.6.1.4.1.674.10892.1.300.10.1.9.1 = 'PowerEdge
2650'
1.3.6.1.4.1.674.10892.1.300.10.1.10.1 = 'ASSETTAG'
1.3.6.1.4.1.674.10892.1.300.10.1.11.1 = '1234567'
1.3.6.1.4.1.674.10892.1.300.10.1.12.1 = 254
1.3.6.1.4.1.674.10892.1.300.10.1.13.1 = 289
1.3.6.1.4.1.674.10892.1.300.10.1.14.1 = 4
1.3.6.1.4.1.674.10892.1.300.10.1.15.1 = 'SERVER01'
1.3.6.1.4.1.674.10892.1.300.10.1.16.1 =
'20050513095213.000000-360'
1.3.6.1.4.1.674.10892.1.300.10.1.17.1 =
'20050513100052.000000-360'
1.3.6.1.4.1.674.10892.1.300.10.1.18.1 = 'Please set
the value'
1.3.6.1.4.1.674.10892.1.300.10.1.19.1 = 'Please set
the value'
1.3.6.1.4.1.674.10892.1.300.10.1.20.1 = 'Please set
the value'
1.3.6.1.4.1.674.10892.1.300.10.1.21.1 = 3
1.3.6.1.4.1.674.10892.1.300.10.1.22.1 = 0
1.3.6.1.4.1.674.10892.1.300.10.1.23.1 = 0
1.3.6.1.4.1.674.10892.1.300.10.1.24.1 = 0
1.3.6.1.4.1.674.10892.1.300.10.1.25.1 = 0
1.3.6.1.4.1.674.10892.1.300.10.1.26.1 = 0
1.3.6.1.4.1.674.10892.1.300.10.1.27.1 = 0
1.3.6.1.4.1.674.10892.1.300.10.1.28.1 = 8
1.3.6.1.4.1.674.10892.1.300.10.1.29.1 = 2
1.3.6.1.4.1.674.10892.1.300.10.1.30.1 = 1

770 SNMP Sample Output


book.book Page 771 Monday, March 14, 2011 3:01 PM

1.3.6.1.4.1.674.10892.1.300.10.1.31.1 = 15
1.3.6.1.4.1.674.10892.1.300.10.1.32.1 = 0
1.3.6.1.4.1.674.10892.1.300.10.1.33.1 = 27
1.3.6.1.4.1.674.10892.1.300.10.1.34.1 = 0
1.3.6.1.4.1.674.10892.1.300.10.1.35.1 = 1
1.3.6.1.4.1.674.10892.1.300.10.1.36.1 = 480
1.3.6.1.4.1.674.10892.1.300.10.1.37.1 = 1
1.3.6.1.4.1.674.10892.1.300.10.1.38.1 = 2
1.3.6.1.4.1.674.10892.1.300.10.1.39.1 = 2
1.3.6.1.4.1.674.10892.1.300.10.1.44.1 = 0
1.3.6.1.4.1.674.10892.1.300.10.1.45.1 = 0
1.3.6.1.4.1.674.10892.1.300.40.1.1.1.1 = 1
1.3.6.1.4.1.674.10892.1.300.40.1.2.1.1 = 1
1.3.6.1.4.1.674.10892.1.300.40.1.3.1.1 = 8
1.3.6.1.4.1.674.10892.1.300.40.1.4.1.1 = 2
1.3.6.1.4.1.674.10892.1.300.40.1.5.1.1 = 'Log
cleared'
1.3.6.1.4.1.674.10892.1.300.40.1.6.1.1 = 2
1.3.6.1.4.1.674.10892.1.300.40.1.7.1.1 = 3
1.3.6.1.4.1.674.10892.1.300.40.1.8.1.1 =
'20050513100047.000000-360'

SNMP Sample Output 771


book.book Page 772 Monday, March 14, 2011 3:01 PM

772 SNMP Sample Output


book.book Page 773 Monday, March 14, 2011 3:01 PM

Index

Numerics BIOS Group tables, 393


1403, 734 BIOS Setup Control Group, 393
variable values, 419
1404, 734
1602, 738
1603, 738 C
1604, 739 Change, 673
1651, 739 Change Management
1652, 740 Group, 673

1653, 740 Chassis Information Group


tables, 77
Chassis Information Table, 77
Event Log Table, 94
A
Firmware Table, 104
Application, 676 Intrusion Table, 107, 109
Application Group, 676 POST Log Table, 92
System BIOS Table, 97
UUID Table, 90
B Variable Values, 114
Cluster Group, 527
BIOS Group
Cluster Table, 527
BIOS Setup Control Table, 393
variable values, 530
Diskette Control Table, 414
IDE Control Table, 412 Cost of Ownership Group
Network Interface Control COO Cost Event Log Table, 450
Table, 416 COO Lease Information
Parallel Port Control Table, 406 Table, 454
SCSI Control Table, 404 COO Maintenance Table, 460
Serial Port Control Table, 408 COO Options Table, 458
USB Control Table, 410 COO Repair Table, 462

Index 773
book.book Page 774 Monday, March 14, 2011 3:01 PM

COO Schedule Number Keyboard Device Table, 270


Table, 457 Memory Device Mapped Address
COO Service Contract Table, 448 Table, 297
COO Support Information Memory Device Table, 289
Table, 464 PCI Device Configuration Space
COO Trouble Ticket Table, 466 Table, 306
COO Warranty Table, 452 PCI Device Table, 303
Cost of Ownership Table, 437 Pointing Device Table, 268
Cost of Ownership tables, 437 Processor Device Table, 273
variable values, 326
Device removed from
D system, 740
data types
common, 761
state capabilities, 762 E
state settings, 763 Event Log
status, 764 viewing entries, 756
status probe, 765
status redundancy, 764
Dell RAC Out-of-Band G
Group, 683
Global Data Group, 556
Chassis Alerts, 704
Chassis Power, 697
Chassis Status, 687
CMC Power Information, 698 I
CMC PSU Information, 702 Introduction
Legacy Alerting, 706 Server Administrator Change
Product Information, 683 Management MIB, 22
Device added to system, 739 Server Administrator
Instrumentation MIB, 17
Device configuration error Server Administrator Remote
detected, 740 Access MIB, 20
Device Group, 674 Server Administrator Storage
Cache Device Table, 283 Management MIB, 21
Generic Device Table, 300 Inventory, 673

774 Index
book.book Page 775 Monday, March 14, 2011 3:01 PM

Inventory Group, 673 O


Operating System Group, 679
Memory Table, 131
L Operating System Table, 129
Local Response Agent Group Operating System Memory
LRA Action Table, 432 Table, 131
LRA Global Settings, 429
LRA Global Settings Table, 430
variable values, 434 P
Local Response Agent Group
Physical Devices Group, 562
tables, 429
Physical Memory Card
Logical Devices Group, 656
Table, 384
Pluggable Device Traps, 739
M Port Group
Keyboard Port Table, 236
Memory device correction rate
Memory Device Port Table, 242
crossed a warning
Monitor Port Table, 245
threshold, 734
Parallel Port Table, 250
Memory device ECC Correctable Pointing Port Table, 233
error count crossed a warning Processor Port Table, 239
threshold, 734
Serial Port Table, 254
Memory Group Small Computer System Interface
Physical Memory Tables, 369 Port Table, 248
variable values, 377, 383 variable values, 261
Memory Group Variable Power Group
Values, 387 AC Power Cord Table, 177
MIB AC Power Switch Table, 175
minor version number, 48 Amperage Probe Table, 169
Battery Table, 180
MIB Major Version Number, 47
Power Supply Table, 160
Power Unit Table, 157
Power Usage Table, 182
variable values, 191

Index 775
book.book Page 776 Monday, March 14, 2011 3:01 PM

Voltage Probe Table, 164 SNMP


Power Group tables, 157 introduction to, 32
SNMP MIB OIDs, 34
Processor Device Status SNMP security, 35
Traps, 737
SNMP traps, 36
Processor sensor detected a
SNMP basic terminology
failure value, 739
fields, 26-27
Processor sensor detected a managed object, 25
warning value, 738 MIB, 25
Processor sensor returned to a SNMP, 24
normal state, 738 variable, 25
SNMP support, configuring, 757
SNMP tables, 28
R
example, 28
Redundant Memory Unit reference guide content, 30, 35
Table, 381
SNMP traps, 759
Remote Access Group
Storage Management Event
Remote Access Table, 478
Group, 669
Remote SNMP Trap Table, 495
Remote User Administration Storage Management
Table, 487 Information Group, 555
Remote User Dial-In System Resource Group
Configuration Table, 504 Direct Memory Access Table, 149
Remote User Dial-Out Table, 507 Input/Output Port Table, 140
Remote Flash BIOS Group Interrupt Table, 146
variable values, 230 Map Table, 135
Memory Table, 143
Owner Table, 137
S variable values, 152
System State Table, 55, 57, 355
sample SNMP output, 767
systems management
Slot Group
software, 49
System Slot Table, 355
build number systems, 50
variable values, 359
description name, 50

776 Index
book.book Page 777 Monday, March 14, 2011 3:01 PM

name, 50-52 U
preferred protocol, 51
User Security Table, 223, 227
supported protocol, 51
version number name, 50

V
T variable names
capability, 27
Thermal Group
settings, 27
Cooling Device Table, 207
state, 27
Cooling Unit Table, 205
status, 27
Temperature Probe Table, 213
variable values, 219 Viewing
SNMP traps, 759
trap variables, 710
current status, 711
data, 711
message, 710
previous status, 711
system, 710
table index OID, 710
traps, 716
AC power cord traps, 735
amperage probe traps, 725
chassis intrusion traps, 728
cooling device traps, 721
fan enclosure traps, 734
hardware log traps, 736
memory device traps, 733
miscellaneous traps, 717
power supply traps, 731
redundancy unit traps, 729
temperature probe traps, 719
understanding the trap
descriptions, 711
understanding trap severity, 716
voltage probe traps, 723

Index 777
book.book Page 778 Monday, March 14, 2011 3:01 PM

778 Index

You might also like