0% found this document useful (0 votes)
16 views20 pages

Connection - 3

The document outlines the structural design calculations for the JAFZA Warehouse Extension project, focusing on beam-column connections according to AISC 360-16 LRFD standards. It includes detailed checks on various components such as welds, columns, bolts, and end plates, confirming their safety under specified load cases. All checks indicate that the structural elements are safe and meet the required capacities.

Uploaded by

Mohamed H
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views20 pages

Connection - 3

The document outlines the structural design calculations for the JAFZA Warehouse Extension project, focusing on beam-column connections according to AISC 360-16 LRFD standards. It includes detailed checks on various components such as welds, columns, bolts, and end plates, confirming their safety under specified load cases. All checks indicate that the structural elements are safe and meet the required capacities.

Uploaded by

Mohamed H
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

Job Number Sheet

DXB - 439 1
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher
S12
Beam - Column Connection - Ver W5.0.00 - 01 Apr 2022

Title : SC3 - RCB1 (DETAIL - D)


Code of Practice : AISC 360-16 LRFD
Created : 04-11-2023 14:48:53

Notes and Assumptions


1 All references are formated "EC3 Part : Section" eg: 8 : 3.6.2(3)a.
for Eurocode 1993-1-8 Section 3.6.2(3)a.
2 All bolt holes are assumed to be normal clearance holes.
3 All bolts are assumed to have threads in their shear planes.
4 It is assumed that the connection is deep enough for the flanges
to resist the compressive and tensile forces in them.
5 It is assumed that compressive forces in flanges and stiffeners
are conveyed through welds and not through bearing.
6 Axial force in the column is not considered in the design.

Summary

Summary of Forces and Capacities for Design to AISC 360-16 LRFD

Check Member Type LC Applied Capacity Units % of Cap. ?

1 Weld Flange 1 115.2 263.1 kN 43.8 O.K.

2 Weld Web 1 41 1204.5 kN 3.4 O.K.

3 Column Web Tension Yielding 1 114.2 1568.5 kN 7.3 O.K.

4 Column Web Compression Crippling 1 115.2 580.9 kN 19.8 O.K.

5 Column Web Compression Buckling 1 115.2 824.6 kN 14 O.K.

6 Column Web Shear 1 115.2 1081.8 kN 10.6 O.K.

7 Bolts & Flange Tension & Bending 1 90.5 141.3 kN 64 O.K.

8 Column Flange Bearing 1 6.8 317.5 kN 2.2 O.K.

9 Bolts & End Plate Tension & Bending 1 90.5 141.3 kN 64 O.K.

10 End Plate Bearing 1 6.8 259.2 kN 2.6 O.K.

11 Bolts Shear 1 6.8 54.3 kN 12.6 O.K.

12 Bolts Shear & Tension 1 45.2 89.8 kN 50.4 O.K.

13 Bolts Slip N/A N/A N/A kN N/A N/A

Input
Job Number Sheet
DXB - 439 2
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

General Settings
Bolt Tension Analysis Elastic
Bolt Type Bearing
Bolt Grade 8.8
Member Ultimate Strength 450
Member Yield Strength 275
Weld Ultimate Strength 480

Connection Type Flush End Plate


Column 610x229x125 I1
Beam 356x127x33 I1
Column Extent Above (mm) 0
Beam Angle 0
Haunch Depth (mm) 200
Haunch Length (mm) 500
Job Number Sheet
DXB - 439 3
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

Ultimate Limit State Loads in Beam SLS Factor


Shear Axial Moment (Divide to
Load Case get Loads)
(kN) (kN) (kNm)
1 41 1 62 1.5

Width (mm) 150


Extent Above Beam Flange (mm) N/A
End Plate Extent Below Beam Flange (mm) N/A
Thickness (mm) 16
Stiffeners N/A
Width (mm) None
Top Stiffener Thickness (mm) None
Column Stiffeners Bottom Stiffener Thickness (mm) None
Shear Stiffener Thickness (mm) None
Shear Stiffener Orientation None
Layout None
Web Plates
Thickness (mm) None
Top Backing Plate Thickness (mm) None
Bottom Backing Plate Thickness (mm) None

Bolts Diameter (mm) 16


Above Top Flange N/A
Below Top Flange 2
Rows of Bolts Above Bottom Flange 1
Below Bottom Flange N/A
Row Spacing (mm) 160
Web (mm) 45
Bolt Offsets Flange (mm) 75
Above Haunch (mm) 90
Beam Flanges (mm) 8
Beam Web (mm) 8
Welds Top Stiffener (mm) N/A
Bottom Stiffener (mm) N/A
Shear Stiffener (mm) N/A

Check 1 : Capacity of the Beam Flange Welds


The worst load is encountered for Load Case : 1
Fw = 115.209 kN

J2-3
Table J2.5

f . Fnw. Awe
Rw =
1000
0.75 ×288 ×1 218.252
=
1000
= 263.142 kN

Beam Flange Weld is safe

Check 2 : Capacity of the Beam Web Welds


Job Number Sheet
DXB - 439 4
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

The worst load is encountered for Load Case : 1


Fw = 41 kN

J2-3
Table J2.5

f . Fnw. Awe
Rw =
1000
0.75 ×288 ×5 576.527
=
1000
= 1 204.530 kN

Beam Web Weld is safe

Check 3 : Capacity of the Column web in tension


Opposite Top flange of the beam :

The worst load is encountered for Load Case : 1


when Fn =114.209 kN

The Capacity of the web is :


J10.2
f . tw. leff . Fyw
Rn =
1000
1.0 ×11.9 ×479.31 ×275
=
1000
= 1 568.542 kN

No tensile forces in the beam bottom flange

Column web is safe in tension

Check 4 : Crippling Capacity of the Column web in Compression


No compressive forces in the beam top flange

Opposite Bottom flange of the beam :

The worst load is encountered for Load Case : 1


when Fn =115.209 kN

The Capacity of the web is :


J10.2
f . tw. leff . Fyw
Rn =
1000
1.0 ×11.9 ×177.5 ×275
=
1000
= 580.869 kN
Job Number Sheet
DXB - 439 5
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher
Column web is safe in compression for crippling

Check 5 : Buckling Capacity of the Column web in Compression


No compressive forces in the top beam flange

Opposite Bottom flange of the beam :

The worst load is encountered for Load Case : 1


when Fn =115.209 kN

J10.3

3 . lb. tw 1.5 . E . Fyw. tf .


f . 0.8 . tw2 . 1 + Qf
d tf tw
Rn =
1000
3 ×8.5 11.9 1.5 200×103 ×275 ×19.6
0.75 ×0.8 ×11.9 2 × 1 + × × ×1.0
612.2 19.6 11.9
=
1000
= 824.624 kN

Column web is safe in compression for buckling

Check 6 : Shear Capacity of the Column Web


The worst load is encountered for Load Case : 1
when Pv =115.209 kN

J10.6
f . 0.6 . Fy. dc. tw
Rn =
1000
0.9 ×0.6 ×275 ×612.2 ×11.9
=
1000
= 1 081.849 kN

Column web shear is safe

Check 7 : Bolt tension and Column Flange Bending


The worst load is encountered for Load Case : 1

Fmax = 90.473 kN
Eurocode 1993-1
8 : 6.2.4
8 : Table 6.2
Job Number Sheet
DXB - 439 6
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

The resistance is the smaller of the 3 possible failure modes :

Mode 1 : Complete yielding of the flange

4 . Mpl + 2 . Mbp.
R1 = 1000
m
4 ×5.69658 + 2 ×0
= ×1000
71.39
= 319.181 kN

Mode 2 : Bolt Failure with yielding of the flange

2 . Mpl . 1000 + n . 2 . Bt
R2 =
m+n
2 ×5.69658 ×1000 + 27 ×2 ×70.65
=
71.39 + 27
= 154.571 kN

Mode 3 : Bolt Failure only

R3 = 2 . Bt
= 2 ×70.65
= 141.300 kN

Therefore R = R3 = 141.3

Bolt tension and Column Flange bending is safe

Check 8 : Bearing on the Column Flange


There are two checks : Check 1 :
The worst load is encountered for Load Case : 1
Fn = 6.833 kN

The Bearing Capacity of the flange at any Bolt is :


J3.10
f . 1.5 . lc. t . Fu
Rn =
1000
0.75 ×1.5 ×75 ×19.6 ×450
=
1000
= 744.188 kN

Check 2 :
The Bearing Capacity of the Plate at any Bolt is :
J3.10
Job Number Sheet
DXB - 439 7
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

f . 3.0 . d . t . Fu
Rn =
1000
0.75 ×3.0 ×16 ×19.6 ×450
=
1000
= 317.520 kN

Column flange bearing is safe

Check 9 : Bolt tension and End Plate Bending


The worst load is encountered for Load Case : 1

Fmax = 90.473 kN
Eurocode 1993-1
8 : 6.2.4
8 : Table 6.2
The resistance is the smaller of the 3 possible failure modes :

Mode 1 : Complete yielding of the End Plate

4 . Mpl .
R1 = 1000
m
4 ×3.05712
= ×1000
38.6
= 316.800 kN

Mode 2 : Bolt Failure with yielding of the End Plate

2 . Mpl . 1000 + n . 2 . Bt
R2 =
m+n
2 ×3.05712 ×1000 + 27 ×2 ×70.65
=
38.6 + 27
= 151.362 kN

Mode 3 : Bolt Failure only

R3 = 2 . Bt
= 2 ×70.65
= 141.300 kN

Therefore R = R3 = 141.3

Bolt tension and End Plate bending is safe

Check 10 : Bearing on the End Plate


There are two checks : Check 1 :
The worst load is encountered for Load Case : 1
Job Number Sheet
DXB - 439 8
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

The Bearing Capacity of the Plate at any Bolt is :


J3.10
f . 1.5 . lc. t . Fu
Rn =
1000
0.75 ×1.5 ×75 ×16 ×450
=
1000
= 607.500 kN

Check 2 :
The Bearing Capacity of the Plate at any Bolt is :
J3.10
f . 3.0 . d . t . Fu
Rn =
1000
0.75 ×3.0 ×16 ×16 ×450
=
1000
= 259.200 kN

End plate bearing is safe

Check 11 : Shear Capacity of the Bolts


The worst load is encountered for Load Case : 1
when Fn =6.833 kN

J3-1
Table J3.2
Fn = 0.45 . Fu
= 0.45 ×800
= 360.000 MPa

The resistance of any bolt is :

n . f . Fn. Ab
Rshear =
1000
1 ×0.75 ×360.000 ×201.062
=
1000
= 54.287 kN

Bolt shear is safe

Check 12 : Shear and Tension Capacity of the Bolts


The worst load is encountered for Load Case : 1
when Fn =45.237 kN

C-J3-8a
J3.7
Job Number Sheet
DXB - 439 9
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

The resistance of any bolt is :

f . Fnt . Ab
Rn =
1000
0.75 ×595.228 ×201.062
=
1000
= 89.758 kN

Bolt shear and tension is safe


Job Number Sheet
DXB - 439 10
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

Bolt Forces

Bolt Forces for Load Case : 1

45.24 kN

29.65 kN

8.52 kN

Shear force per bolt : 6.83 kN


Job Number Sheet
DXB - 439 1
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher
S12
Beam - Column Connection - Ver W5.0.00 - 01 Apr 2022

Title : PRC1 - ST2 (DETAIL - B)


Code of Practice : AISC 360-16 LRFD
Created : 04-11-2023 14:50:35

Notes and Assumptions


1 All references are formated "EC3 Part : Section" eg: 8 : 3.6.2(3)a.
for Eurocode 1993-1-8 Section 3.6.2(3)a.
2 All bolt holes are assumed to be normal clearance holes.
3 All bolts are assumed to have threads in their shear planes.
4 It is assumed that the connection is deep enough for the flanges
to resist the compressive and tensile forces in them.
5 It is assumed that compressive forces in flanges and stiffeners
are conveyed through welds and not through bearing.
6 Axial force in the column is not considered in the design.

Summary

Summary of Forces and Capacities for Design to AISC 360-16 LRFD

Check Member Type LC Applied Capacity Units % of Cap. ?

1 Weld Flange 1 188.9 681.6 kN 27.7 O.K.

2 Weld Web 1 18.5 1008.4 kN 1.8 O.K.

3 Column Web Tension Yielding 1 99.9 932.8 kN 10.7 O.K.

4 Column Web Compression Crippling 1 188.9 607 kN 31.1 O.K.

5 Column Web Compression Buckling 1 188.9 847.1 kN 22.3 O.K.

6 Column Web Shear 1 188.9 1081.8 kN 17.5 O.K.

7 Bolts & Flange Tension & Bending 1 79.3 141.3 kN 56.1 O.K.

8 Column Flange Bearing 1 3.1 317.5 kN 1 O.K.

9 Bolts & End Plate Tension & Bending 1 79.3 141.3 kN 56.1 O.K.

10 End Plate Bearing 1 3.1 259.2 kN 1.2 O.K.

11 Bolts Shear 1 3.1 54.3 kN 5.7 O.K.

12 Bolts Shear & Tension 1 39.6 90.3 kN 43.9 O.K.

13 Bolts Slip N/A N/A N/A kN N/A N/A

Input
Job Number Sheet
DXB - 439 2
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

General Settings
Bolt Tension Analysis Elastic
Bolt Type Bearing
Bolt Grade 8.8
Member Ultimate Strength 450
Member Yield Strength 275
Weld Ultimate Strength 480

Connection Type Flush End Plate


Column 610x229x125 I1
Beam 203x203x46 H1
Column Extent Above (mm) 0
Beam Angle 0
Haunch Depth (mm) 200
Haunch Length (mm) 500
Job Number Sheet
DXB - 439 3
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

Ultimate Limit State Loads in Beam SLS Factor


Shear Axial Moment (Divide to
Load Case get Loads)
(kN) (kN) (kNm)
1 18.5 89 58 1.5

Width (mm) 240


Extent Above Beam Flange (mm) N/A
End Plate Extent Below Beam Flange (mm) N/A
Thickness (mm) 16
Stiffeners N/A
Width (mm) None
Top Stiffener Thickness (mm) None
Column Stiffeners Bottom Stiffener Thickness (mm) None
Shear Stiffener Thickness (mm) None
Shear Stiffener Orientation None
Layout None
Web Plates
Thickness (mm) None
Top Backing Plate Thickness (mm) None
Bottom Backing Plate Thickness (mm) None

Bolts Diameter (mm) 16


Above Top Flange N/A
Below Top Flange 2
Rows of Bolts Above Bottom Flange 1
Below Bottom Flange N/A
Row Spacing (mm) 80
Web (mm) 40
Bolt Offsets Flange (mm) 60
Above Haunch (mm) 100
Beam Flanges (mm) 12
Beam Web (mm) 10
Welds Top Stiffener (mm) N/A
Bottom Stiffener (mm) N/A
Shear Stiffener (mm) N/A

Check 1 : Capacity of the Beam Flange Welds


The worst load is encountered for Load Case : 1
Fw = 188.886 kN

J2-3
Table J2.5

f . Fnw. Awe
Rw =
1000
0.75 ×288 ×3 155.608
=
1000
= 681.611 kN

Beam Flange Weld is safe

Check 2 : Capacity of the Beam Web Welds


Job Number Sheet
DXB - 439 4
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

The worst load is encountered for Load Case : 1


Fw = 18.5 kN

J2-3
Table J2.5

f . Fnw. Awe
Rw =
1000
0.75 ×288 ×4 668.319
=
1000
= 1 008.357 kN

Beam Web Weld is safe

Check 3 : Capacity of the Column web in tension


Opposite Top flange of the beam :

The worst load is encountered for Load Case : 1


when Fn =99.886 kN

The Capacity of the web is :


J10.2
f . tw. leff . Fyw
Rn =
1000
1.0 ×11.9 ×285.048 ×275
=
1000
= 932.820 kN

No tensile forces in the beam bottom flange

Column web is safe in tension

Check 4 : Crippling Capacity of the Column web in Compression


No compressive forces in the beam top flange

Opposite Bottom flange of the beam :

The worst load is encountered for Load Case : 1


when Fn =188.886 kN

The Capacity of the web is :


J10.2
f . tw. leff . Fyw
Rn =
1000
1.0 ×11.9 ×185.5 ×275
=
1000
= 607.049 kN
Job Number Sheet
DXB - 439 5
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher
Column web is safe in compression for crippling

Check 5 : Buckling Capacity of the Column web in Compression


No compressive forces in the top beam flange

Opposite Bottom flange of the beam :

The worst load is encountered for Load Case : 1


when Fn =188.886 kN

J10.3

3 . lb. tw 1.5 . E . Fyw. tf .


f . 0.8 . tw2 . 1 + Qf
d tf tw
Rn =
1000
3 ×20.5 11.9 1.5 200×103 ×275 ×19.6
0.75 ×0.8 ×11.9 2 × 1 + × × ×1.0
612.2 19.6 11.9
=
1000
= 847.121 kN

Column web is safe in compression for buckling

Check 6 : Shear Capacity of the Column Web


The worst load is encountered for Load Case : 1
when Pv =188.886 kN

J10.6
f . 0.6 . Fy. dc. tw
Rn =
1000
0.9 ×0.6 ×275 ×612.2 ×11.9
=
1000
= 1 081.849 kN

Column web shear is safe

Check 7 : Bolt tension and Column Flange Bending


The worst load is encountered for Load Case : 1

Fmax = 79.256 kN
Eurocode 1993-1
8 : 6.2.4
8 : Table 6.2
Job Number Sheet
DXB - 439 6
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

The resistance is the smaller of the 3 possible failure modes :

Mode 1 : Complete yielding of the flange

4 . Mpl + 2 . Mbp.
R1 = 1000
m
4 ×3.38778 + 2 ×0
= ×1000
29.84
= 454.126 kN

Mode 2 : Bolt Failure with yielding of the flange

2 . Mpl . 1000 + n . 2 . Bt
R2 =
m+n
2 ×3.38778 ×1000 + 37.3 ×2 ×70.65
=
29.84 + 37.3
= 179.417 kN

Mode 3 : Bolt Failure only

R3 = 2 . Bt
= 2 ×70.65
= 141.300 kN

Therefore R = R3 = 141.3

Bolt tension and Column Flange bending is safe

Check 8 : Bearing on the Column Flange


There are two checks : Check 1 :
The worst load is encountered for Load Case : 1
Fn = 3.083 kN

The Bearing Capacity of the flange at any Bolt is :


J3.10
f . 1.5 . lc. t . Fu
Rn =
1000
0.75 ×1.5 ×60 ×19.6 ×450
=
1000
= 595.350 kN

Check 2 :
The Bearing Capacity of the Plate at any Bolt is :
J3.10
Job Number Sheet
DXB - 439 7
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

f . 3.0 . d . t . Fu
Rn =
1000
0.75 ×3.0 ×16 ×19.6 ×450
=
1000
= 317.520 kN

Column flange bearing is safe

Check 9 : Bolt tension and End Plate Bending


The worst load is encountered for Load Case : 1

Fmax = 79.256 kN
Eurocode 1993-1
8 : 6.2.4
8 : Table 6.2
The resistance is the smaller of the 3 possible failure modes :

Mode 1 : Complete yielding of the End Plate

4 . Mpl .
R1 = 1000
m
4 ×2.93832
= ×1000
37.1
= 316.800 kN

Mode 2 : Bolt Failure with yielding of the End Plate

2 . Mpl . 1000 + n . 2 . Bt
R2 =
m+n
2 ×2.93832 ×1000 + 46.375 ×2 ×70.65
=
37.1 + 46.375
= 148.900 kN

Mode 3 : Bolt Failure only

R3 = 2 . Bt
= 2 ×70.65
= 141.300 kN

Therefore R = R3 = 141.3

Bolt tension and End Plate bending is safe

Check 10 : Bearing on the End Plate


There are two checks : Check 1 :
The worst load is encountered for Load Case : 1
Job Number Sheet
DXB - 439 8
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

The Bearing Capacity of the Plate at any Bolt is :


J3.10
f . 1.5 . lc. t . Fu
Rn =
1000
0.75 ×1.5 ×60 ×16 ×450
=
1000
= 486.000 kN

Check 2 :
The Bearing Capacity of the Plate at any Bolt is :
J3.10
f . 3.0 . d . t . Fu
Rn =
1000
0.75 ×3.0 ×16 ×16 ×450
=
1000
= 259.200 kN

End plate bearing is safe

Check 11 : Shear Capacity of the Bolts


The worst load is encountered for Load Case : 1
when Fn =3.083 kN

J3-1
Table J3.2
Fn = 0.45 . Fu
= 0.45 ×800
= 360.000 MPa

The resistance of any bolt is :

n . f . Fn. Ab
Rshear =
1000
1 ×0.75 ×360.000 ×201.062
=
1000
= 54.287 kN

Bolt shear is safe

Check 12 : Shear and Tension Capacity of the Bolts


The worst load is encountered for Load Case : 1
when Fn =39.628 kN

C-J3-8a
J3.7
Job Number Sheet
DXB - 439 9
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

The resistance of any bolt is :

f . Fnt . Ab
Rn =
1000
0.75 ×599.031 ×201.062
=
1000
= 90.332 kN

Bolt shear and tension is safe


Job Number Sheet
DXB - 439 10
Job Title
JAFZA WAREHOUSE EXTENSION
Client
Your details here M.S / Ocean World Lines International LLC
Calcs by Checked by Date
Gnanadoss Siva Christopher

Bolt Forces

Bolt Forces for Load Case : 1

39.63 kN

27.75 kN

0 kN

Shear force per bolt : 3.08 kN

You might also like