0% found this document useful (0 votes)
17 views4 pages

skbpc5004 skbpc5016

The document provides specifications for the SKBPC5004 to SKBPC5016 series of bridge rectifiers, detailing their electrical characteristics, maximum ratings, and applications. These rectifiers are designed for general-purpose three-phase applications, with a maximum recurrent peak reverse voltage ranging from 400V to 1600V and a forward current capability of 50A. Additional notes include compliance with ROHS and flammability classification, along with a disclaimer regarding product specifications and intended use.

Uploaded by

Tempestuoso
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views4 pages

skbpc5004 skbpc5016

The document provides specifications for the SKBPC5004 to SKBPC5016 series of bridge rectifiers, detailing their electrical characteristics, maximum ratings, and applications. These rectifiers are designed for general-purpose three-phase applications, with a maximum recurrent peak reverse voltage ranging from 400V to 1600V and a forward current capability of 50A. Additional notes include compliance with ROHS and flammability classification, along with a disclaimer regarding product specifications and intended use.

Uploaded by

Tempestuoso
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

SKBPC5004

THRU
SKBPC5016

Features
 SKBPC
Io 50A VRRM 400V~1600V
ƽ

Glass passivated chip


ƽ

1.134(28.8) Hole for


ƽ
High surge forward current capability 1.110(28.2) #10 Screw
.980(24.9) .229(5.59) DIA
.200(5.08)
Applications .941(23.9)

ƽ
General purpose 3 phase Bridge rectifier .669(17.0) 1.134(28.8)
applications .630(16.0) 1.110(28.2)

ƽ Epoxy: Device has UL flammability


.033(0.85)
classification 94V-O .029(0.75) .251(6.4)
.244(6.2)

.944(25.0)
.441(11.2) MAX
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS .425(10.8)
Ratings at 25 o C ambient temperature unless otherwise specified. METAL HEAT SINK

resistive or inductive load.


Dimensions for inches and (millimeters)

MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)


SKBPC50
RATINGS SYMBOL 04 06 08 10 12 14 16 UNITS
Maximum Recurrent Peak Reverse Voltage VRRM 400 600 800 1000 1200 1400 1600 Volts
Maximum RMS Voltage VRMS 280 420 560 700 840 980 1120 Volts
Maximum DC Blocking Voltage VDC 400 600 800 1000 1200 1400 1600 Volts
Maximum Average Forward Rectified Current
o IO 50 Amps
at T A = 50 C
Peak Forward Surge Current 8.3 ms single half sine-wave
I FSM 500 Amps
superimposed on rated load (JEDEC method)
2
Current Squarad Time I T 1040 A 2 Sec

Typical Thermal Resistance (Note 1) R1 JC 0.9 0


C/ W
Dielectric Strength ,Terminals to case ,AC 1 minute Vdis 2.5 KV

0
Operating and Storage Temperature Range T J, T STG -40 to+ 150 C

ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)

CHARACTERISTICS SYMBOL 04 06 08 10 12 14 16 UNITS


Maximum Instantaneous Forward Voltage at 17.0A DC VF 1.2 Volts

Maximum DC Reverse Current


IR 10 uAmps
at Rated DC Blocking Voltage @T A = 25 o C

NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted. 2024-02/10


2. " ROHS compliant" REV:B
3. Available in Halogen-free epoxy by adding suffix -HF after the part nbr.
RATING AND CHARACTERISTICS CURVES (SKBPC5004 THRU SKBPC5016)

೒ 1˖ Io-Ta᳆㒓 ೒˖㗤ℷ৥⌾⍠⬉⌕᳆㒓
FIG1:Io-Ta Curve FIG2:Surge Forward Current Capadility

IFSM(A)
Io(A)

70 700
 ℷᓺ⊶
sine wave

IFSM
60
0
8.3ms 8.3ms

1 cycle
50
500
ϡ䞡໡
40 non-repetitive
Ta=25ć

30
250
20

10

0 0
0 50 100 150 1 2 5 10 20 50 100
਼⊶᭄
Ta(ć ) Number of Cycles

೒˖ℷ৥⬉य़᳆㒓 ೒˖ড৥⬉⌕᳆㒓
FIG3:Instantaneous Forward Voltage FIG4:Typical Reverse Characteristics
IR(uA)
IF(A)

60 100

40 Tj=125ć

20 Ta=25ć

10
10

5.0

1.0

1.0
Tj=25ć

0.5 0.1

0.2

0.1
0.4 0.6 0.8 1.0 1.2 1.4 0.01
VF(V) 0 20 40 60 80 100
Voltage(%)

" " " "" " "


RECTRON
Attachment information about SKBPC50X

Marking on the body

Part No. SKBPC50 X X


Voltage-code

Rectron Logo VXXX 04-------400V 10-----1000V


Plant - code 0 6-------600V 12-------200V
Year - code 0 8-------800V 14-----1400V
Week - code 16-----1600V
DISCLAIMER NOTICE

Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi-
lity for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" paramet-
ers which may be included on RECTRON data sheets and/ or specifications ca-
n and do vary in different applications and actual performance may vary over ti-
me. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.

Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other rela-
ted applications where a failure or malfunction of component or circuitry may di-
rectly or indirectly cause injury or threaten a life without expressed written appr-
oval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rect-
ron Inc and its subsidiaries harmless against all claims, damages and expendit-
ures.

You might also like