Manual DTL150
Manual DTL150
Important reminder
,
If U≥120V then P≤60W
01
产品展示
Product exhibition
寸
2.4 TFT Set button
主机介绍
02
技术参数
Technical
parameter
03
界面介绍
Interface
The interface introduction is for clear display, made by a computer, and may differ from the actual
introduction
display effect. The final display effect is based on the actual product!
2.2 Constant voltage working mode and settable working voltage (requires
manual switching of working mode)
5.1Voltage, current, and power over limit protection (can be set independently)
OVP-Overvoltage protection
OPP-Overcurrent protection
OPP-Overpower protection
7.1Limited time discharge --: -- Unlimited time discharge (default state) can be
set independently
8.2 Voltage over limit protection stop over limit warning+preset protection
voltage
8.3 Current over limit protection stop over limit warning+preset protection
current
8.4 Power over limit protection stop over limit warning+preset
protection power
9.1 Menu
04
使用方法
Wiring
method
01 02 03
Voltage and current
calibration RESET No return to zero
with no load
Calibrated
04 05 06
07 08 09
10 11
05
使用演示
Application
examples
Prepare a power supply that can set DC 30V3A constant current and constant voltage, and set
Connect the power supply to the load using a four wire or two wire system, and
Long press the ON/OFF button for 3 seconds to enter the system menu
Voltage calibration
Click the SET key to switch the cursor to the voltage calibration option
Click the button "+" to confirm the calibration voltage, and a "OK"
complete,
Current calibration
Click the SET key to switch the cursor to the current calibration option
Click the button "ON/OFF" to start the load, and the current calibration item displays
real-time current
Click the button "+" to confirm the calibration current, and a "OK"
prompt will pop up on the screen indicating that the calibration is
complete,
Calibration completed, click the SET key to switch the cursor to the exit menu, and
click the "+" button to exit the system menu
—warn—
点击图标查看如何恢复出厂设置
RESET
Enter the system menu
Long press the ON/OFF button for 3 seconds to enter the system menu
Click the "+" button to confirm the restoration of factory settings, and a "OK" prompt
will pop up on the screen indicating that the restoration is complete
Zeroing without load
Empty parameter is not zero
When the load is not started or not connected to the load power supply, real-time
readings of voltage, current, and power indicate no load return to zero
When there is interference in the usage environment, a single reset cannot be made
If multiple operations still fail to return to zero, it can only be counted as a system
error
The interface display after returning to the main interface after clearing the empty
load (the figure shows the display of connecting to a 30V power supply)
Accumulated data reset
Clear historical cumulative data when starting a new cumulative cycle
Including three cumulative data: cumulative operating time, energy, and capacity
The interface display after returning to the main interface after clearing the empty
Switch the working mode according to your own needs, and after switching the working mode,
click "SET" to switch to other items
Or continuously click "SET" to exit the setup
Overlimit protection settings
Press and hold the "SET" button for 2 seconds on the main interface to enter the
auxiliary parameter setting mode. Working mode CC flashing
After completing the adjustment, click the "SET" button to switch to the power
over limit protection setting
Set the overrun protection parameters according to your own needs, and click "SET" to
switch to other options after completion
Stop voltage (low voltage protection) setting
Press and hold the "SET" button for 2 seconds on the main interface to enter the
auxiliary parameter setting mode. Working mode CC flashing
Set the stop voltage (low voltage protection) according to your own needs, and click "SET" to
switch to other options after completion
Limited time discharge setting
Press and hold the "SET" button for 2 seconds on the main interface to enter the
auxiliary parameter setting mode. Working mode CC flashing
After setting the minute period, click "SET" to switch to the limited time discharge
2 (hour period) setting
Flashing for 2 (hour) period of limited time discharge
Click the "+" or "-" keys to adjust to the target time, with a maximum setting of 99
hours
After setting the discharge time according to your own needs, click "SET" to exit the setting
Discharge parameter settings
Taking CC mode as an example for demonstration, the setting method for other working modes is the same
Click the "SET" button on the main interface to switch and set the cursor position
After the cursor reaches the target mantissa, click the "+" or "-" keys to adjust to
the target current
After adjusting to the target parameters, the settings are completed. Press "ON/OFF" to start
the load or make other settings according to the needs
Operating load
Taking CC mode as an example for demonstration, the starting method for other working modes is the same
Click the "ON/OFF" button to activate the load status indicator "ON"
When it is necessary to stop the load, click the "ON/OFF" button to stop the load
status indicator "OFF"