TM 11 6130 413 12

Download as pdf or txt
Download as pdf or txt
You are on page 1of 34

TM 11-6130-413-12

TECHNICAL MANUAL

OPERATORS AND ORGANIZATIONAL MAINTENANCE MANUAL

BATTERY CHARGER-ANALYZER AN/USM-432 (NSN 6130-01-055-1574)


This copy is a reprint which includes current pages from Change 1.

HEADQUARTERS,

DEPARTMENT OF THE ARMY 31 MARCH 1980

TM 11-6130-413-12

C1
CHANGE No. 1 HEADQUARTERS DEPARTMENT OF THE ARMY WASHINGTON, DC, 7 October 1981
OPERATOR'S AND ORGANIZATIONAL MAINTENANCE MANUAL

BATTERY CHARGER-ANALYZER AN/USM-432(NSN 6130-01 -055-1 574)


TM 11-6130-413-12, 31 March 1980, is changed as follows: 1. New or changed material is indicated by a vertical bar in the margin. 2. Remove old pages and insert new pages as indicated below:

a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .a l-l and l-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..l-1 and l-2 2-l and 2-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...2-1 and 2-2 2-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...2-3 3-3 and 3-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..3-3 and 3-4 4-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...4-3 D-3 through D-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..D-3 through D-5

File this change in front of the publication for reference purposes.

By Order of the Secretary of the Army E. C. MEYER General, United States Army Chief of Staff

official: ROBERT M. JOYCE Brigadier General, United States Army The Adjutant General DISTRIBUTION: To redistributed in accordance with Special List.

TM 11-6130-413-12

WARNINGS
HIGH VOLTAGE is used in this equipment DEATH ON CONTACT may result if safety precaution are not observed. Be careful not to come in contact with high voltage connections or any power connections when repairing or adjusting this equipment. Turn off the power and discharge all capacitors before making any connections or doing any work inside the equipment. Battery Charger-Analyzer AN/USM-432 should be used only with a properly GROUNDED AC POWER SOURCE. EXTREME HEAT builds up on the back of the AN/USM-432 during the battery discharge cycle. Do not touch the back of the unit or SERIOUS BURNS will result.

Change 1

TM 11-6130-413-12

WARNINGS
DANGEROUS CHEMICALS ARE USED IN NICKEL-CADMIUM BATTERIES The electrolyte used in nickel-cadmium batteries contains potassium hydroxide (KOH), which is a caustic chemical agent. Serious and deep burns of body tissue will result if the electrolyte comes in contact with the eyes or any part of the body. Use rubber gloves, rubber apron, and protective goggles when handling the electrolyte. If accidental contact with the electrolyte is made, use ONLY clean water and immediately (seconds count) flush contaminated areas. Continue flushing with large quantities of clean water. Seek medical attention without delay. EXPLOSIVE GASES ARE GENERATED BY NICKEL-CADMIUM BATTERIES Hydrogen and oxygen gases are generated in explosive proportion while the nickel-cadmium battery is being charged. Charge the nickel-cadmium battery in a wellventilated area to reduce concentrations of explosive gases. Turn off the battery charger before connecting or disconnecting the nickel-cadmium battery to prevent arcing. Do not use matches or an open flame in the charging area. Arcs, flames, or sparks in the charging area will ignite the gases and cause an explosion. The battery box cover must be removed and the battery case vent plug (if used) must be open when charging. DO NOT MIX SULPHURIC ACID AND KOH The electrolyte used in nickel-cadmium batteries reach violently to the sulphuric acid used in the more common lead-acid types of batteries. DO NOT add sulphuric acid electrolyte to the battery; the mixing of the acid and KOH electrolytes will cause a violent reaction which could result in the splattering of the mixture into the eyes and onto the skin. Every effort must be made to keep nickel-cadmium batteries as far away as possible from lead-acid batteries. Do not use the same tools and materials such as screwdrivers, wrenches, syringes, hydrometers, and gloves for both types of batteries. Any trace of acid or acid fumes will permanently damage nickel-cadmium batteries on contact.

TM 11-6130-413-12

WARNINGS
BATTERY SHOP SAFETY PRACTICES Nickel-cadmium battery maintenance personnel should be thoroughly trained in the use of charging, discharging, and test procedures. The employment of properly trained personnel in the maintenance of nickel-cadmium batteries cannot be overemphasized. The nickel-cdmium battery shop must be used ONLY to maintain nickel-cadmium batteries. Anything associated with lead-acid batteries should never come in contact with nickel-cadmium batteries, including acid fumes. In addition to the equipment required to maintain nickel-cadmium batteries; the nickel-cadmium battery shop should have adequate ventilation; deluge shower, eyewash fountain, and fire extinguisher (CO2). TIGHTENING TERMINAL SCREWS AND STUDS Be extremely careful when tightening terminal screws and studs. Bodily injury and damage to the equipment may result if the torque wrench accidentally causes a short circuit.

TM 11-6130-413-12

WARNINGS
Battery Charger-Analyzer AN/USM-432 is HEAVY. Use two-man lift whenever unpacking or moving the unit. Adequate ventilation should be provided while using TRICHLOROTRIFLUOROETHANE. Prolonged breathing of vapor should be avoided. The solvent should not be used near heat or open flame; the products of decomposition am toxic and irritating. Since TRICHLOROTRIFLUOROETHANE dissolves natural oils, prolonged contact with skin should be avoided. When necessary, use gloves which the solvent cannot penetrate. If the advent is taken internally, consult a physician immediately. To be usable for cleaning, the COMPRESSED AIR source must limit the nozzle pressure to no more than 29 pounds per square inch gauge (PSIG). Goggles must be worn at all times while cleaning with compressed air. CAUTION
ACID CONTAMINATES NICKEL-CADMIUM BATTERRIES

Every effort must be made to keep nickel-cadmium batteries as far away as possible from lead-acid batteries because lead-acid batteries contain sulphuric acid. Do not use the same tools and materials, such as screwdrivers, wrenches, syringes, hydrometer, and gloves for both types of batteries. Any trace of acid or acid fumes will permanently damage nickel-cadmium batteries on contact.

TM 11-6130-413-12

TECHNICAL MANUAL NO. 11-6130-413-12

HEADQUARTERS DEPARTMENT OF THE ARMY WASHINGTON, DC, 31 MARCH 1980

OPERATORS AND ORGANIZATIONAL MAINTENANCE MANUAL

BATTERY CHARGER-ANALYZER AN/USM-432 (NSN 6130-01 -055-T574)


REPORTING ERRORS AND RECOMMENDING IMPROVEMENTS You can help improve this manual. If you find any mistakes or if you know of a way to improve the procedures, please let us know. Mail your letter, DA Form 2028 (Recommended Changes to Publications and Blank Forms), or DA Form 2028-2 located in back of this manual direct to: Commander, US Army Communications and Electronics Materiel Readiness Command, ATTN: DRSEL-ME-MQ, Fort Monmouth, NJ 07703. In any case, a reply will be furnished direct to you.

C HAPTER Section

1. I.

II.

CHAPTER Section

2. I.

II.

CHAPTER Section

3. I.

II.

CHAPTER Section

4.
I.

II.

III.

Section

IV.

Paragraphs Pages INTRODUCTION GENERAL 1-1 Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1-1 Indexes of Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1-1 Forms and Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 1-1 Administrative Stooge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 1-1 Destruction of Army Electronics Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 1-1 Equipment Improvement Recommendations (EIR). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 DESCRIPTION AND DATA 1-1 Purpose and Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 1-2 System Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 1-2 Tabulated Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 1-2 Equipment Supplied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 SERVICE UPON RECEIPT AND INSTALLATION SERVICE UPON RECEIPT OF EQUIPMENT 2-1 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-1 Checking Unpacked Equipment.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 INSTALLATION INSTRUCTIONS 2-1 Tools, Test Equipment and Materials Required for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 2-1 Installation Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 OPERATING INSTRUCTIONS CONTROLS AND INDICATORS 3-1 3-1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 OPERATION UNDER USUAL AND UNUSUAL CONDITIONS 3-2 Operating Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 3-4 Damage from Improper Control Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 3-4 Procedures for Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 Operation Under Unusual Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 3-4 OPERATOR/ORGANIZATIONAL MAINTENANCE INSTRUCTIONS TOOLS AND EQUIPMENT 4-1 Scope of Organizational Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 4-1 Tools, Materials and Test Equipment Requird for Organizational Maintenance . . . . . . . . . . . . . . . . . 4-2 REPAINTING AND REFINISHING INSTRUCTIONS 4-1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 4-1 Repainting and Refinishing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 PREVENTIVE MAINTENANCE CHECKS 4-1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 4-1 Preventive Maintenance Checks.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6 4-I Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 TROUBLESHOOTING 4-2 Troubleshooting Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 4-3 Removal and Replacement of Knobs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9

TM 11-6138-413-12

Pages APPENDIX A. B. C. D. Section I. II. III. VI. REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Components of End Item List (Not Applicable) Additional Authorization List (Not Applicable) Maintenance Allocation ....................................................................................................................................................... D-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .......................... D-1 Maintenance Allocation Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...... .... D-3 Tool and test equipment requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... ................ D-4 Remarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..................... D-5

ii

TM 11-6130-413-12

Figure 1-1. Battery Charger-Analyzer. AN/USM-432.

1-0

TM 11-6130-413-12

CHAPTER 1 INTRODUCTION
Section 1. GENERAL

1-1. Scope a. This manual describes Battery Charger-Analyzer AN/USM-432 (fig. l-l) and covers its installation operation, function, and maintenance. It includes operation under usual and unusual conditions, cleaning and inspection of the equipment and replacement of parts available to the organizational maintenance repairman. b. Throughout this manual Battery Charger-Analyzer AN/USM-432 will be referred to as charger/ analyzer. c. Appendix A contains a list of publications applicable to this equipment. Appendix D contains the maintenance allocation and repair operations to be performed at the appropriate maintenance categories. 1-2. Index of Technical Publications Refer to the latest issue of DA Pam 310-4 to determine whether there are new editions, changes, or additional publications pertaining to the equipment. 1-3. Maintenance Forms, Records, and Reports a. Reports of Maintenance and Unsatisfactory Equipment. Department of the Army forms and procedures used for equipment maintenance will be those prescribed by TM 38-750, The Army Maintenance Management System (Army). b. Report of Packaging and Handling Deficiencies. Fill out and forward SF 364 (Report of Discrepancy (ROD)) as prescribed in AR 735-11-2/DLAR 4140.55/NAVMATINST 4355.73/AFR 400-54/MCO 4430.3E.

c. Discrepancy in Shipment Report (DISREP) (SF 361). Fill out and forward Discrepancy in Shipment Report (DISREP) (SF 361) as prescribed in AR 55-38/NAVSUPINST 4610.33B/AFR 75-18/ MCO P4610.19C/DLAR 4500.15. 1-4. Administrative Storage Administrative storage of equipment issued to and used by Army activities will have preventive maintenance performed in accordance with the PMCS charts before storing. When removing the equipment from administrative storage, the PMCS should be performed to assure operational readiness. The original shipping container should be retained for repacking of equipment for shipment or limited storage. 1-5. Destruction of Army Electronics Material Demolition and destruction of electronic equipment will be under the direction of the commander and in accordance with TM 750-244-2. 1-6. Reporting Equipment Improvement Recommendations (EIR) If your charger-analyzer needs improvement, let us know. Send us an EIR. You, the user, are the only one who can tell us what you dont like about your equipment. Let us know why you dont like the design. Tell us why a procedure is hard to perform. Put it on an SF 368 (Quality Deficiency Report). Mail it to Commander, US Army CommunicationsElectronics Command, ATTN: DRSEL-ME-MQ, Fort Monmouth, New Jersey 07703. Well send you a reply.

Sectlon II. DESCRIPTION AND DATA 1-7. Purpose and Use The charger/analyzer is intended for use as an item of support equipment for charging and testing nickel-cadmium batteries used on certain types of aircraft. The charger/analyzer is a self-contained unit, utilizing automatically- programmed charge and discharge circuits for servicing various types of vented 24-volt (19- or 20-cell) nickel-cadmium batteries with capacities ranging from 5 to 40 AH (ampere hours). All operator controls and instrumentation are accessible from the front panel. The unit is furnished with integral input and output. Change 1 1-1

TM 11-6130-413-12 power cables and requires no additional special interconnecting wiring or external power source cabling. Input leads are 5-foot, flexible, rubbercovered stranded copper, and terminated with an appropriate plug for connection to designated ac power source. Output leads are 6-foot, flexible, rubber-covered stranded copper, and terminated with a type MS25182 battery disconnect plug for connection to an MS3509 aircraft. storage battery electrical receptacle. The charger/analyzer uses solid-state circuitry with internal heat sinks and convection cooling and requires no external source of cooling air. a. Charger Mode. When used in the charger mode of operation, the unit is capable of pulse-charging a nickel-cadmium battery from any state of discharge to full capacity within one hour, based on the recommended charging rate in the appropriate battery manual. When the battery terminal voltage reaches the charge termination voltage specified for the battery, the charging current is reduced to a topping charge until the cycle is terminated automatically by the charge timer. b. Discharge Mode. The unit is also capable of discharging batteries at a rate equal to, or greater than, their one-hour ampere rating. If the battery terminal voltage reaches a specified volts-per-cell before the one hour of discharge is completed the unit will indicate a failure and suspend operation. 1-8. System Application Operation of the charger/analyzer is fully automatic, once the operator programs the necessary controls and cycling to match the battery under test/ charge. Normal operation generally includes the following five phases: NOTE Phase 3, 4, and 5 are automatic, including termination except for periodic voltage checks of each cell which may be accomplished during charging cycles. Operator can reset unit to any phase at any time. a. Phase 1: Capacity Test. Battery is discharged at rated capacity (for 1 hour). If battery reaches a terminal voltage of 0.95 volts 5% per cell before 1 hour elapses, the charger/analyzer indicates a FAIL condition and battery is checked to determine if it is faulty. If 1 hour or more elapses before battery cell voltage is 0.95 volts 5% the battery is considered as acceptable and the operator can determine it capacity. b. Phase 2: Equalization Discharge. All cells are discharged simultaneously to zero volts. (The operator must short individual cells as their voltage drops below 0.5 volts.) c. Phase 3: Initial Charge. Battery is pulsecharged to full capacity. One hour is required for this phase on 5 AH to 50 AH batteries. d. Phase 4: Capacity Test. Battery is discharged at the 1 hour rate. If a terminal voltage of less than 0.95 volts per cell 5% is not reached within 1 hour, charger/analyzer indicates that battery passes capacity test and indicates battery capacity. If the battery reaches 0.95 volts 5% per cell before one hour, unit indicates a rejected battery and terminates operation at this point, not continuing to phase 5. e. Phase 5: Final Charge. Battery is pulsecharged to full capacity. One hour is required for this phase. 1-9. Tabulated Data
Item Characteristic Dimensions . . . . . . . . . . . . . . . . . 17 in. w. (43.2 cm) x 25 in. D (63.5 cm) x 16.75 in. H. (42.5 cm). Weight . . . . . . . . . . . . . . . . . . . . 166 lb. (75.5 kg) crated 143 lb. (65 kg) uncrated. Power Input Requirements . . . . 188 volts ac 253 volts ac, single phase, 50/60 Hz 30 amperes. Output Characteristics. . . . . . . . Groups of 120 Hz pulses, to pulse charge 5 to 40 A H NiCad batteries (19 or 20 cells). Duty Cycle . . . . . . . . . . . . . . . . . Continuous Operating Temperature Range . +32 F. (0 C.) to +113 F. (45 C.). Nonoperating (storage) Temperature Range . . . . . . . . -79 F. (62 C.) to +160 F. (+71 C.). Operating Altitude Range . . . . . 0 to 5000 ft. Non-operation Altitude Range. . 0 to 8000 ft. Relative Humidity . . . . . . . . . . . to 95%. Protective Features . . . . . . . . . . Open-circuit protection polarityreversal protection; short-circuit protection overload protection. Total Heat Dissipation . . . . . . . . 1200 watts maximum

1-10. Equipment Supplied All necessary cables for input and output electrical connections are furnished integral to the equipment. Other than voltmeter leads, no additional equipment is required to ensure that the charger/ analyzer performs its intended function.

1-2

Change 1

TM 11-6130-413-12

CHAPTER 2 SERVICE UPON RECEIPT AND INSTALLATION


Section 1. SERVICE UPON RECEIPT OF EQUIPMENT 2-1. Unpacking (fig. 2-1) a. Packing Data. The battery charger analyzer is shipped in a heavy duty carton with adequate internal cardboard cartons and packing material designed to provide maximum protection against mechanical shock and other damage during transit. b. Material Handling. No special material handling equipment is necessary for unpacking or handling of the crated unit. However, care should be taken when moving the equipment to avoid any excessive shock or vibration. Four men using reasonable precautions, may carry the crated unit to the installation area. c. Unpacking Instructions (fig. 2-1). (1) Cut tape sealing top of box, fold back flaps and turn box on side. (2) Remove bagged unit and set upright on base. Discard carton. (3) Slit open bag and peel away from box, slit open inner box and remove unit. Note that handles are folded down against sides of unit; to grasp handles, cut away sides of box. (4) Grasp side handles ( 4- man lift), lift unit out of box and place unit on convenient work surface for inspection. 2-2. Checking Unpacked Equipment a. Inspect the equipment for damage that may have occurred during shipment. If the equipment has been damaged, fill out and forward DD Form 6 (Report of Packaging and Handling Deficiencies) (para 1-3b). b. Check to see that the equipment is complete as listed on the packing slip. Report all discrepancies in accordance with TM 38-750. c. Check to see whether the equipment has been modified. If the equipment has been modified, the MWO number will appear on the front panel near the nomenclature plate. Check also to see whether all MWOs current at the time the equipment is placed in use have been applied. NOTE Current MWOs applicable to the equipment are listed in DA Pam 310-7. d. Check the latest issue of DA Pam 310-4 (never more than 1 year old) and its latest changes (never more than 6 months old) to see whether you have the latest editions of all applicable maintenance literature (equipment issued by depots may have been in stock for some time and may contain superseded manuals).

Section II. INSTALLATION INSTRUCTIONS 2-3. Tools, Test Equipment, and Materials Required for Installation No special tools are required to install the battery charger/analyzer. Common hand tools associated with electronic equipment installation and maintenance are sufficient for ail installation tasks. A multimeter can be used for simple electrical measurement. 2-4. Installation Instructions The unit is completely self-maintained, with all controls and indicator accessible at the front panel. It is intended for placement on a work bench , with free air flow, and does not require special racks or mounts. a. The charger/analyzer is equipped with a four prong ac power plug; however, only three of the four wires in the cable are used (red, black and green). Should it be necessary to change the ac power plug, note that the green wire is the ground and the white wire is not used. b. Interconnections. The charger/analyzer is designed to operate from ac supply voltages ranging from 188 volts to 253 volts, single-phase, 50/60 Hz, 30 amperes. As shipped, the charger/analyzer power transformer taps are connected for operation from a 230-volt (nominal) supply source (207 volts ac to 253 volts at). If the available source voltage differs, it will be necessary to reconnect internal taps to match available power source before equipment is placed into operation. To set internal transformer (Tl) primary winding taps, refer to figure 2-2 and proceed as follows: WARNINGS Disconnect power source before changing primary winding taps. Dangerous voltages are present when power source is connected. Do not attempt to make internal connections or adjustments unless another person, capable of first aid is present. Change 1 2-1

TM 11-6130-413-12

Figure 2-1. AN/USN-432 unpacking

CAUTION Do not connect equipment to power source until all tap connections are made or equipment damage may result. (1) Using ac voltmeter, measure ac supply voltage input directly at source receptacle. (2) Remove the 25 screws from the top cover of the charger/analyzer. 2-2

(3) Connect the transformer taps as indicated b e low to correspond with the available power source:
Transformer Terminal Connections 207v ac to 253v ac (230V ac Black wire to 230V terminal nominal) . . . . . . . . . . . . . . . . . 187v ac to 229v ac (208v ac Black wire to 208V terminal. nominal) . . . . . . . . . . . . . . . . . Power Source

TM 11-6130-413-12

Figure 2-2. Power Transformer T1, Input Voltage Tap Connections

CAUTION The 5% taps are factory pre-set and should be changed only if a unit tends to over- or under-charge. Do not change the tap unless replacing T1. c. Operation at 50Hz. To operate at power line frequency of 50 Hz the timer face plates must be reversed as follows. (1) Remove 25 screws from the top cover of the charger/analyzer and remove cover. (2) Remove the three (3) timer knobs by loosening the two setscrews on each knob. (3) Remove 7 phillips screws and nuts holding the face plate. Hold the nuts to prevent their falling into the charger/analyzer. (4) Reverse the face plate and reattach using the screws and nuts removed in step (3); replace timer knobs in original position and tighten setscrews. d. Installation Checkout. Refer to the preliminary operation check out procedures given in section 3 to verify that the equipment is properly installed and ready for operation.

Change 1

2-3

TM 11-6130-413-12

CHAPTER 3 OPERATING INSTRUCTIONS


Section 1. CONTROLS AND INDICATORS

3-1. General This chapter describes operating controls and indicators and operating procedures under usual and unusual conditions. Note that operating procedures are described for typical applications; local requirements may require variations of these steps. 3-2. Controls and Indicators (fig. 3-1)
Control or Indication Power ON-OFF Switch (CB1) . . Function Controls overall application of power to charger/analyzer circuits and provides circuit protection from overloads and shorts. Momentary pushbutton switch which is depressed to reset power relay and restore overall equipment operation. Provides circuit protection for internal equipment timing and control circuits. Three-position rotary switch which selects discharge resistor banks for specific battery discharge rates. Variable control sets charges current reference. (One hour rate.) Variable control sets discharge current reference. (One hour rate.) Toggle switch adjusts internal EOD and charge comparator circuits to correspond with appropriate number of battery cells. Center-zero meter continuously indicates charge or discharge current from -l00A to +100A. Dual range meter; indicates overall battery voltage on the 0-30V scale, or individual cell voltage on the 0-3V scale (external leads required). depending on position of 30V-3V switch. Selects voltage range to be monitored by VOLTAGE meter. In 3OV position, meter reads battery charging/discharge voltage; in 3V position, ex-

Control or Indicator

Function ternal test leads can be connected to terminals J4 (+) and J3 (-) to measure individual cell voltage. Provides connection for external test leads. Momentary pushbutton switch depressed to remove unit from a reset state and initiate operation. Lights RUN indicator (DS6) and indicator above appropriate timer (DS1, DS3 or DS5). Amber lamp lights when START switch is pressed and equipment is in a normal operating cycle. Momentary pushbutton switch which is depressed to interrupt operation and rest.ore unit to a logical reset state. Multi-position rotary switch selects equipment operating mode OFF; MANUAL DISMANUAL CHARGE; CHARGE; or AUTO. One-hour timer controls first phase of automatic charge cycle-not used during manual charge. Indicates (amber lamp) that AUTQ-CHARGE No. 1 timer (M3) is operating.

(+) and (-) terminals (J4, J3). . START switch (S2) . . . . . . . . . .

RUN indicator (DS6). . . . . . . . .

POWER RESET Switch (S5). . .

RESET switch (Sl) . . . . . . . . . .

FUSE, l AMP(FI) . . . . . . . . . .

DISCHARGE AMP HR Switch (S7) . . . . . . . . . . . . . . . . . . . .

FUNCTION SELECT switch (S4) . . . . . . . . . . . . . . . . . . .

CHARGE AMP HR control (R16) . . . . . . . . . . . . . . . . . . . DISCHARGE AMP control (R15) . . . . . . . . . . . . . . . . . . .

AUTO-CHARGE No. 1 timer (M3) . . . . . . . . . . . . . . . . . . . .

Run indicator (DS5). . . . . . . . . .

CELL SELECT switch (S6) . . . .

CURRENT meter (M5) . . . . . . .

VOLTAGE meter (M4) . . . . . . .

30V-3V switch (S3). . . . . . . . .

AUTO/MANUAL DISCHARGE timer . . . . . . . . . . . . . . . Two-hour timer used during automatic operation for controlled discharge to End-Of-Discharge (EOD); used during manual operation for deep discharge. FAIL indicator (DS4). . . . . . . . . Indicates that end-of-discharge (EOD) occurred before 1 hour (in discharge) elapsed. Run indicator (DS3). . . . . A m b e r l a m p indicates that AUTO/MANUAL DISCHARGE timer (M2) is operating. PASS indicator (DS2) . . . . . . . . Green lamp indicates that EOD has occurred after 1 hour of discharge AUTO/MAN CH/\RGE No. 2 timer (Ml) . . . . . . . . . . . . One-hour timer used during the last phase of the cycle for auto-

3-1

TM 11-6130-413-12
Control or Indicator Function Control or Indicator Powercord(P3) . . . . . . . . . . . . . Function

matic charging; or for manual charging. Run indicator (DSl). . . . . . . . . . Amber lamp indicates the AUTO/MAN CHARGE No. 2

timer (Ml) is operating. Provides connection to local power source. Battery connector (J5) . . . . . . . Provides connection to battery.

Section II. OPERATION UNDER USUAL AND UNUSUAL CONDITIONS 3-3. Operating Procedures The following are the complete normal operating procedures. For operational checkout procedures after installation, servicing or as a periodic check, refer to paragraph 4-8. Connect dc output connector J5 to the known good battery, connect ac connector P3 to the local ac power source, then perform the following procedures: CAUTION Before you connect any nickel-cadmium battery to the charger/analyzer, determine the correct charge/discharge rates and safety precautions by referring to the appropriate battery manual (TM 11-6140-203-14-2, TM 11-6140-203-14-3, or TM 11-6140-20315-1).

Figure 3-1. Controls and Indicators.

3-2

TM 11-6130-413-12 CAUTION Before connecting or disconnecting a battery, make sure the charger/analyzer is in RESET. Do not connect or disconnect a battery when the RUN light is on. NOTE The capacity test (initial discharge) and equalization discharge may be eliminated if discharge racks are used. a. Phase 1Capacity Test (Initial Discharge). Proceed as follows: (1) Set ON-OFF switch (CBl) to OFF position. (2) Set CELL SELECT to match battery to be charged. (3) Set AUTO-CHARGE No. 1 timer (M3) fully ccw then back to 1 HR position. (4) Set AUTO/MANUAL DISCHARGE timer (M2) to START position. (5) Set AUTO/MAN CHARGE No. 2 timer (MI) fully ccw then back to 1 HR position. (6) Set ON-OFF switch (CB1) to ON position. (7) press POWER RESET switch (S5) momentarily. (8) Set FUNCTION SELECT switch (S4) to AUTO position. (9) Set 30V-3V switch (S3) to 30V position. (10) Set DISCHARGE AMP-HR switch (S7) to appropriate position for l-hour rate. (11) Set CHARGE AMP-HR control (R16) to appropriate position for l-hour rate. Note that battery should trickle-charge during the final 5 to 10 minutes of the charge cycle; adjust control accordingly. (12) Set DISCHARGE AMP control (R15) to appropriate position. Use ammeter for precise setting. (13) If fail light comes on, clear it by moving AUTO-CHARGE No. 1 tier cw then back to 1 HR position. (14) Press START switch (S2) momentarily to initiate operational cycle and observe that the following actions occure. (a) RUN indicator (amber, DS6) illuminates, (b) Discharge indicator (amber, DS3) illuminates. (c) Battery VOLTAGE (M4) and CURRENT (M5) meters display battery condition. (d) PASS (DS2) or FAIL (DS4) indicator illuminate at EOD. PASS indicates that battery discharged for at least 1 hour before reaching EOD. (15) Monitor cell VOLTAGE during the last 15 minutes of discharge. b. Phase 2-Equalization (Manual Discharge). This is a continuation of Phase 1; proceed as follows: (1) Set FUNCTION SELECT switch (S4) to MANUAL DISCHARGE position, and the DISCHARGE timer to START position. (2) Press START switch (S2) momentarily to initiate operational cycle. Unit will discharge battery continuously; cell voltage must be monitored by operator. If desired, set 30V-3V switch (s3) to 3V position, connect test leads to (+) and (-) 3V terminals (J4, J3) and monitor cell voltage on VOLTMETER (M4). Short individual cells in accordance with the battery manual when the monitored cell voltage drops to 0.5 volts; this will ensure that each cell is at zero volts. (3) Proceed to next phase when cell voltages are at zero (deep discharge). c. Phase 3, 4, 5-Initial Charge, Capacity Test, Final Charge (Auto Cycle). This is a continuation of Phase 2; proceed as follows: (1) Set 30V-3V switch (S3) to 30V position and disconnect any test leads used in phase 2. (2) Set AUTO-CHARGE No. 1 timer (M3) to START position. (3) Set AUTO/MANUAL DISCHARGE timer (M2) to START position. (4) Set AUTO/MAN CHARGE No. 2 timer (MI) to START position. (5) Set FUNCTION SELECT switch (S4) to AUTO position. (6) Set DISCHARGE AMP-FIR (S7), CHARGE AMP-HR(R-16), DISCHARGE AMP (R-15) and CELL SELECT (S6) to appropriate positions, according to battery type. (7) Press START switch (S2) momentarily to initiate automatic cycle and observe that the following actions occur: (a) RUN indicator (DS6) illuminates. (b) Automatic charge indicator (DS5) illuminates. (c) CURRENT meter (M5) reads full scale for less than a second, falls back to 0, then rises again to full scale at next cycle. (Note that unit emits an audible deep vibration each charge cycle, in synchronization with the meter movement). (d) VOLTAGE meter (M4) reads 26-28 volts after 40 to 50 minutes and unit continues to charge battery, at a lower rate, for remainder of cycle. (CURRENT meter (M5) still pulses, but for shorter time periods during each interval; voltage meter is read during non-active part of pulse cycle. (e) Monitor cell VOLTAGE during the last 15 minutes of the charge cycle. (f) After a 60-minute period, AUTO CHARGE NO. 1 timer (M3) stops, the associated run indicator (DS5) extinguishes, AUTO/MANUAL DISCHARGE timer (M2) begins operation and the associated run indicator (DS3) illuminates. (g) Battery discharge continues at a constant rate until EOD is reached (0.95 volts/cell). (h) If EOD is reached after the 60-minute period, PASS indicator (DS2) illuminates, AUTO/MANUAL DISCHARGE time (M2) stops (providing an indiChange 1 3-3

TM 11-6130-413-12 cation of actual battery capacity), associated run indicator (DS3) extinguishes, AUTO/MAN CHARGE NO. 2 timer (M1) begins operation and the associated run indicator (DS1) illuminates. If EOD is reached in less than 60 minutes, FAIL indicator (DS 4) illuminate, timer (M2) stops, and charge i S not started. (i) At the end of the cycle, all indicator extinguish except PASS (DS2) and unit enters a RESET mode. 3-4. Damage from Improper Control Settings a. Operational Errors. The equipment cannot be damaged from improper control settings. If the operator changes control function settings during mid-cycle, or uses the wrong control settings for the battery parameter, internal detection circuits operate quickly to shut down the unit. If this occurs, recheck for proper control settings and restart unit to complete the interrupted cycle. b. Resets. During discharge cycle, if charger/ analyzer seems to be reset, possibly due to selection of the wrong discharge rate (over-current condition), reselect proper range, set DISCHARGE AMP control R15) down to 0, re-initiate START (S2) and slowly bring DISCHARGE AMP control (R-15) up to appropriate CURRENT (MS) level for the selected range. Note that this procedure will not operate in automatic discharge if charger/analyzer had failed EOD before 1 hour (FAIL light on). If this condition occurs, reset AUTO CHARGE NO. 1 timer (M3) CW, then back to the timed-out condition; or advance AUTO/MANUAL DISCHARGE timer (M2) past the l-hour marking. (Perform the former procedure if setting of AUTO/MANUAL DISCHARGE timer (M2) is not to be disturbed.) 3-5. Procedures for Shutdown Equipment operation can be fully terminated at any time, in the event of failure or external conditions, by setting the ON-OFF circuit breaker (CBl) to OFF position. Disconnect unit from ac power source and from battery connection. 3-6. Operation U n d e r U n u s u a l C o n ditions The following precautions should be observed for operation of the equipment where extreme climatic conditions may exist: a. Operation in Artic Climates. Subzero temperatures and climatic conditions associated with cold weather may-adversely affect equipment functioning. Follow these precautions: (1) Handle equipment carefully. (2) Keep equipment clean and dry. (3) Prevent ice from forming on the equipment. Ice formation may inhibit control operation. (4) At temperature less than 32F. (OC.) neither rated capacity of discharge nor full charge in 1 hour will be obtained. b. Operation in Desert Climates. Heat and dryness associated with desert environment will not affect the operation of the equipment. However, dust storms can cause controls to bind and damage associated equipment. When the equipment is not in use cover connectors with plastic bags. Do not charge at battery temperatures above 120F. (49C.).

3-4

Change 1

TM 11-6130-413-12

CHAPTER 4 OPERATOR/ORGANIZATIONAL MAINTENANCE lNSTRUTlONS


Section 1. TOOLS AND EQUIPMENT

4-1. Scope of Organizational Maintenance The maintenance duties at this category are listed below together with a reference to the paragraphs covering the specific maintenance functions. The paragraphs include instructions for performing corrective maintenance. a. Repainting and refinishing (para 4-3). b. Daily preventive maintenance checks and services (para 4-6). c. Cleaning (para 4-7). d. Functional test (para 4-8). e. Knob replacement (para 4-9).

4-2. Tools, Materials, and Test Equipment Required for Organizational Maintenance No special tools or test equipment are required for organizational maintenance. Refer to the maintenance allocation chart (MAC) in appendix B and the following listing: a. Tool Kit, Electronic Equipment TK- 101/G. b. Multimeter AN/URM- 105. c. Trichloroethane. d. Cleaning cloth. e. Fine sandpaper (No. 000). f. Soft bristle brush. g. Paint Gray, Alkali-Resistant. h. Paintbrush.

Section Il. REPAINTING AND REFINISHING INSTRUCTIONS 4-3. General When the finish on the equipment has been badly scarred or damaged, further damage can be prevented by touching up the damaged surfaces, being careful not to paint electrical terminals, especially ground terminals. 4-4. Repainting and Refinishing Remove dirt from the equipment by cleaning affected areas with trichloroethane or No. 000 sandpaper to complete the preparation for painting. Apply paint with a small brush; brush two thin coats of paint on the bare spots to protect from further deterioration. Refer to TM 43-0139, Painting Instructions for Field Use. Approved paints and finishes are listed in SB 11-573.

Section Ill. PREVENTIVE MAINTENANCE CHECKS AND SERVICES 4-5. General Preventive maintenance is the systematic care, servicing, and inspection of equipment to prevent the occurrence of trouble, to reduce downtime, and to maintain the equipment in serviceable condition. Defects that cannot be corrected must be reported to personnel at a higher maintenance category. Routine checks like cleaning, dusting, washing, checking for frayed cables, stowing items not in use, covering unused receptacles and checking for frayed cables, towing items not in use, covering unused receptacles and checking for loose nuts and screws are not listed as preventive maintenance checks or services. They are things that you should do anytime you see they must be done, 4-6. Preventive Maintenance Checks The functional test procedure in paragraph 4-8 should be used to speedily determine the condition of the charger/analyzer when the equipment is initially installed, reinstalled after removal for any reason, and at least once a week if the equipment is maintained in a standby condition. 4-7. Cleaning Inspect the exterior surfaces of the equipment. All exterior surfaces should be clean and free of dirt, grease, and fungus. a. Remove dust and loose dirt with a clean, soft cloth. 4-1

TM 11-6130-413-12 WARNING Adequate ventilation should be provided while using TRICHLOROTRIFLUOROETHANE. Prolonged breathing of vapor should be avoided. The solvent should not be used near heat or open flame; the products of decomposition are toxic and imitating. Since TRICHLOROTRIFLUOROETHANE dissolves natural oils, prolonged contact with skin should be avoided. When necessary, use gloves which the solvent cannot penetrate. If the solvent is taken internally, consult a physician immediately.

Sectlon IV. TROUBLESHOOTING circuit, turn the Discharge AMP HR control to zero, 4-8. Troubleshooting Procedures press START, and then set the desired discharge curThe responsibilities of the organizational repairman rent. Return the control to the original position. Since are limited to correction of equipment failures which the Discharge AMP HR switch will be in the 17-31 can be remedied by replacement of a defective cable asposition, the range of adjustment will be approximatesembly, fuse or knob. All other maintenance procedly 17 to 31 amperes. Press RESET and disconnect the ures relating to test, repair or overhaul are to be accharged battery. Connect the discharged battery and complished at a higher category of maintenance. To turn the Charge 1 timer cw until the FAIL light goes determine the condition of the charger/analyzer when off, then turn the timer back until the timer switch installing initially, reinstalling after repair, or when clicks. Now press START. The current should remain equipment is maintained in a standby condition, perat set point, and the battery voltage will drop below form the procedure below: .95 volts per cell after a few minutes of discharge, the a. Functional Test. Two serviceable batteries are retime depending on the remaining charge in the batquired, preferable in the range of 30-40AH capacity. tery. Since 1 hour has not passed, the FAIL light One should be nearly discharged, the other charged. should come on at this point, and the RUN light go off. CAUTION The unit should stop. This verifies the FAIL logic. Make sure that charger/analyzer is in RESET Press RESET, disconnect the discharged battery and before disconnecting and reconnecting batconnect the charged battery. Turn the Charge 1 timer teries. Do not connect a battery when the cw until the FAIL light goes off, then turn the timer RUN light is on. back until the timer switch clicks. The unit will return (1) Set up the charger/analyzer for automatic to Discharge. Slowly turn the Discharge timer ccw to operation, Phases 3, 4, 5. (Procedure is in para 3-3.) the 2-hour mark. When it reaches that point, the Connect the discharged battery and start the unit. The Charge 2 light should come on and the Discharge light ammeter will deflect to nearly full scale for between .4 go off. The green PASS light will come on as charging and .75 seconds, then return to zero. It will repeat this begins. every second (slightly longer at 50 Hz). Move the (3) Turn this Charge 2 timer slowly ccw until the Charge AMP HR control to higher and lower settings. switch clicks. At that point the Charge 2 and RUN The charging pulse will be longer at higher settings, lights will go off, charging stops, and the PASS light shorter at low settings. Return the setting to the propremains on. This concludes the check of the automatic er position for the battery used. Let the unit charge for modes of operation, Phases 3,4,5. a few minutes, then press RESET and disconnect the (4) Disconnect the charged battery and reconnect discharged battery. Connect the charged battery and the discharged battery. Set up the charger/analyzer for press START. The unit should charge, but as the voltManual Discharge (para. 3-3). Allow the unit to run age rises to 28.5 vdc between pulses, the charge curuntil the battery voltage is below .95 volts per cell. rent will drop to an indicated 50-70 amperes and the This verifies correct operation of the Manual Distime of the charging pulse will drop to a fraction of the charge circuit (EOD disabled in this mode of operaprevious time, roughly a tenth of a second. (The time it tion). takes to go to the lower charge rate will depend on the b. Battery Cable Assembly. The battery cable asstate of charge of the battery). Turn the Charge 1 timsembly interconnects the battery under charge/test er by hand to the l-hour mark. The unit will switch auwith the equipment via a two-pin MS-type connector, tomatically to Discharge, the Charge 1 light will go J3; and heavy-duty battery cables. Inspect the connecoff, and the Discharge light will go on. tor for general appearance and tightness of contacts. (2) Observe that the discharge current is constant. Check battery (+) and (-) contracts for corrosion and Move the Discharge AMP HR control to higher and sand lightly with No. 000 sandpaper, if necessary. lower settings to verify that the current can be controlCheck cables for frayed wiring or loose connecters led. When the discharge setting is too high, an internal Note that defective contacts are usually indicated by sensor will trip out the discharge circuit. To reset this arcing or overheating. 4-2

WARNING Dangerous voltages are present within the equipment. Always disconnect power cable before opening up the unit for inspection or service. c. Power Cable Assembly. The power cable assembly is a three-wire cable terminated by a 4-pin connector, P3. A defective cable maybe indicated when operation of front-panel switching does not energize the equipment. Check cable continuity; if an open or high-resistance is indicated, the cable is defective and should be replaced. d. Fuse. Fuse F2 is rated for 100 amperes and protects the charger circuits against external battery cable shorts or reverse connections. If the equipment is energized when ac power is supplied but the battery does not charge, or no voltage is measured on voltmeter (M4) with switch (S3) in the W-volt position, F2 should be suspected. Fuse F2 is located inside the unit at the top right side and is retained by blade-type contacts. Remove the fuse, check continuity and replace, if necessary.

e. Timers. The charge timers control the length of the charge cycle, while the discharge timer determines whether the battery has passed or failed the c a p a c i t y t e s t . Check the timers for proper switchover points, with the equipment turned off, by turning the timer knobs ccw until. a click is heard, The click for the charge timers should occur at the 1 h o u r point. The click for the discharge timer should occur at the 6 0 m i n u t e s setting. If the switchover points (clicks) occur at other than those times given above, then an adjustment is required. If necessary, the switchover point cm be corrected by loosening and readjusting the timer knobs. 4-9. Removal and Replacement of Knobs Each of the control knobe is secured to the respective shaft by two setscrews before removing a knob, set the control to a readily identifiable position so that thereplacement knob can be set accurately to the same original position. To replace a knob, loosen or remove the setscrew and carefully lift the knob from the shaft. Before replacement, check to see that the knob dial pointer tracks properly with dial markings.

Change 1

4-3

TM 11-6130-413-12

APPENDIX A REFERENCES

A-1

TM 11-6130-413-12

APPENDIX D MAINTENANCE ALLOCATION


Section I. INTRODUCTION

D-1. General This appendix provides a summary of the maintenance operations for AN/USM-432. It authorizes categories of maintenance of specific maintenance functions on repairable items and components and the tools and equipment required to perform each function. This appendix may be used as an aid in planning maintenance operations. D-2. Maintenance Function Maintenance functions will be limited to and defined as follows: a. Inspect. To determine the serviceability of an item by comparing its physical, mechanical, and/or electrical characteristics with established standards through examination. b. Test. To verify serviceability and to detect incipient failure by measuring the mechanical or electrical characteristics of an item and comparing those characteristics with prescribed standards. c. Service. Operations required periodically to keep an item in proper operating condition; i.e., to clean (decontaminate), to preserve, to drain, to paint, or to replenish fuel, lubricants, hydraulic fluids, or compressed air supplies. d. Adjust. To maintain, within prescribed limits, by bringing into proper or exact position, or by setting the operating characteristics to the specified parameters. e. Align. To adjust sptxified variable elements of an item to bring about optimum or desired performance. f. Calibrate. To determine and cause connections to be made or to be adjusted on instruments or test measuring and diagnostic equipments used in precision measurement. Consists of comparisons of two instruments, one of which is a certified standard of known accuracy, to detect and adjust any discrepancy in the accuracy of the instrument being compared. g. Install. The act of emplacing, seating, or fixing into position an item, part, module (component or assembly) in a manner to allow the proper functioning of the equipment or system. h. Replace. The act of substituting a serviceable like type part, subassembly, or module (component or assembly) for an unserviceable counterpart. i. Repair. The application of maintenance services

(inspect, test, service, adjust, align, calibrate, replace) or other maintenance actions (welding, grinding, riveting, straightening, facing, remachining, or resurfacing) to restore serviceability to an item by correcting specific damage, fault, malfunction, or failure in a part, subassembly, module (component or assembly), end item, or system. j. Overhaul. That maintenance effort (service/action) necessary to restore an item to a completely serviceable/operational condition as prescribed by maintenance standards (i.e., DMWR) in appropriate technical publications. Overhaul is normally the highest degree of maintenance performed by the Army. Overhaul does not normally return an item to like new condition. k. Rebuild. Consists of those services/actions necessary for the restoration of unserviceable equipment to a like new condition in accordance with original manufacturing standards. Rebuild is the highest degree of materiel maintenance applied to Army equipment. The rebuild operation includes the act of returning to zero those age measurements (hours, miles, etc.), considered in classifying any equipments/components. D-3. Column Entries a. Column 1, Group Number. Column 1 lists group numbers, the purpose of which is to identify component, assemblies, subassemblies, and modules with the next higher assembly. b. Column 2, Component/Assembly. Column 2 contains the noun names of components, assemblies, sub assemblies, and modules for which maintenance is authorized. c. Column 3, Maintenance Functions. Column 3 lists the functions to be performed on the item listed in column 2. When items are listed without maintenance functions, it is solely for purpose of having the group numbers in the MAC and RPSTL coincide. d. Column 4, Maintenanwce Category. Column 4 specifies, by the listing of a work time figure in the appropriate subcolumn(s), the lowest level of maintenance authorized to perform the function listed in column 3. This figure represents the active time required to perform that maintenance function at the indicated category of maintenance. If the number or complexity of the tasks within the listed maintenance function vary at different maintenance categories. D-1

TM 11-6130-413-12

appropriate work time figures will be shown for each category. The number of task-hours specified by the work time figure represents the average time required to restore an item (assembly, subassembly, component, module, end item or system) to a serviceable condition under typical field operating conditions. This time includes preparation time, troubleshooting time, and quality assurance/quality control time in addition to the time required to perform the specific tasks identified for the maintenance functions authorized in the maintenance allocation chart. Subcolumns of column 4 areas follows: C-Operator/Crew O-Organizational FDirect Support H-General Support D-Depot e. Column 5, Tools and Equipment. Column 5 specifies by code, those common tool sets (not individual tools) and special tools, test, and support equipment required to perform the designated function. f. Column 6, Remarks. Column 6 contains an alphabetic code which leads to the remark in section IV, Remarks, which is pertinent to the item opposite the particular code.

D-4 Tool and Test Equipment Requirements (Sec Ill) a. Tool or Test Equipment Reference Code. The numbers in this column coincide with the numbers used in the tools and equipment column of the MAC. The numbers indicate the applicable tool or test equipment for the maintenance functions. b. Maintenance Category. The codes in this column indicate the maintenance category allocated the tool or test equipment. c. Nomenclature. This column lists the noun name and nomenclature of the tools and test equipment required to perform the maintenance functions. d. National/NATO Stock Number. This column lists the National/NATO stock number of the specific tool or test equipment. e. Tool Number. T h i s c o l u m n l i s t s t h e manufacturers part number of the tool followed by the Federal Supply Code for manufacturers (5digit) in parentheses. D-5. Remarks (See IV) a. Reference Code. This code refers to the appropriate item in section II, column 6. b. Remarks. This column provides the required explanatory information necessary to clarify items appearing in section II.

D-2

TM 11-6130-413-12

SECTION II MAINTENANCE ALLOCATlON CHART FOR


BATTERY CHARGER-ANALYZER AN/USM-432 (1) GROUP NUMBER 00 (2) COMPONENT/ASSEMBLY (3) MAINTENANCE FUNCTION Inspect Test Inspect Service Test Replace Replace Test Repair Overhaul 01 CONTROL BOARD ASSEMBLY Test Replace Test Repair (4) MAINTENANCE CATEGORY C 0.1 3.0 O F H D (5) TOOLS AND EQPT. 10 2 2 1 2 4,5,6,9 3 3 : 3, 4 thru 11 4,5 3 4,5,7,8 3 (6) REMARKS

BATTERY CHARGER-ANALYZER AN/USM-432

0.2 0.2 0.2 0.3

A B A C D E E F

1.0 1.0 1.0 0.2 0.2

40

0.5 1.0

Change 1 D-3

TM 11-6130-413-12 SECTION III TOOL AND TEST EQUIPMENT REQUIREMENTS FOR

BATTERY CHARGER-ANALYZER AN/USM-432 TOOL OR TEST EQUlPMENT REF CODE I 2 3 4 5 6 7 8 0 O H, D H, D H, D H, D D D MAINTENANCE CATEGORY MULTIMETER, AN/URM-105 TOOL KIT, ELECTRONIC EQUIPMENT TK-101/G TOOL KIT, ELECTRONIC EQUIPMENT TK-105/G MULTIMETER, AN/USM-223 OSCILLOSCOPE, AN/USM/281C STOP WATCH TEST SET, SEMICONDUCTOR DEVICE TS-1836D/U BRIDGE, IMPEDANCE ZM-71/U NOMENCLATURE NATIONAL NATO STOCK NUMBER 6625-00-581-2036 5180-00-064-5178 5180-00-610-8177 6625-00-999-7465 6625-00-106-9622 6645-00-903-1696 6625-00-138-7320 6625-00-236-1536

TOOL NUMBER

ADDITIONAL AUTHORIZATION LIST 9 10 11 C, O, H, D D D BATTERY, VENTED NI-CD, 24 VOLT 5 TO 40 H.H. BATTERY CHARGER-ANALYZER AN/USM-432 EXTENDER TEST BOARD

AAL

3-4 Change 1

TM 11-6130-413-12 SECTION IV.


REFERENCE CODE A B C D E F EXTERIOR OPERATIONAL CONTINUITY FUSES, POWER CABLES, LAMPS FUSES, POWER CABLES, ELCON CONNECTOR, LED INDICATORS, KNOBS EVERYTHING ALL EXCEPT CONTROL BOARD

REMARKS
REMARKS

Change 1 D-5

By Order of the Secretary of the Army:

Official: J. C. PENNINGTON Major General, United States Army The Adjutant General

E. C. MEYER General, United States Army Chief of Staff

6 U. S. GOVERNMENT PRINTING OFFICE : 1992 0 - 311-831 (61092)

THE METRIC SYSTEM AND EQUIVALENTS

PIN :

044373-001

This fine document...


Was brought to you by me:

Liberated Manuals -- free army and government manuals


Why do I do it? I am tired of sleazy CD-ROM sellers, who take publicly available information, slap watermarks and other junk on it, and sell it. Those masters of search engine manipulation make sure that their sites that sell free information, come up first in search engines. They did not create it... They did not even scan it... Why should they get your money? Why are not letting you give those free manuals to your friends? I am setting this document FREE. This document was made by the US Government and is NOT protected by Copyright. Feel free to share, republish, sell and so on. I am not asking you for donations, fees or handouts. If you can, please provide a link to liberatedmanuals.com, so that free manuals come up first in search engines:
<A HREF=http://www.liberatedmanuals.com/>Free Military and Government Manuals</A>

Sincerely Igor Chudov http://igor.chudov.com/

You might also like