FireCR Flash User Manual EN 150413 Fin
FireCR Flash User Manual EN 150413 Fin
3DISC, FireCR, Quantor and the 3D Cube are trademarks of 3D Imaging & Simulations Corp,
South Korea, and its affiliates. All other trademarks are held by their respective owners and
are used in an editorial fashion with no intention of infringement. The data in this publication
are for illustration purposes only and do not necessarily represent standards or specifications,
which must be met by 3D Imaging & Simulations Corp. All information contained herein is
intended for guidance purposes only, and characteristics of the products and services described
in this publication can be changed at any time without notice. Products and services may not
be available in your local area. Please contact your local sales representative for availability
information. 3D Imaging & Simulations Corp. strives to provide as accurate information as
possible, but shall not be responsible for any typographical error.
Contact
Tel : 82-42-931-2100
Fax : 82-42-931-2299
Website : www.3DISCimaging.com
E-mail : [email protected]
3DISC Americas
22560 Glenn Dr, Suite 116
Sterling, VA 20164 USA
Tel : 1-703-430-6080
E-mail : [email protected]
3DISC Europe
Gydevang, 39-41, 3450 Alleroed, Denmark
Tel : 45-88-276-650
E-mail : [email protected]
2
User Manual
FireCR Flash TM-401-EN
The device complies with Part 15 of the FCC Rules. Operation is subject to the condition
that this device does not cause harmful interference.
NOTE : This equipment has been tested and found to comply with the limits for a Class B Digital
Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction, may cause harmful interference to radio communication. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment dose
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures : - Reorient or relocate the receiving antenna. - Increase the
separation between the equipment and receiver - Connect the equipment into an outlet on a
circuit different from that to which the receiver is connected. - Consult the dealer or an
experienced radio/TV technician for help.
3
User Manual
FireCR Flash TM-401-EN
To ensure the safety of patients, staff and other persons, any changes to software and hardware
delivered by 3D Imaging & Simulations Corp. may only be made with prior written permission
from 3D Imaging & Simulations Corp.
Please read the respective manuals of the connected software, such as acquisition and
diagnostic software, before starting to use the system.
DANGER
General prohibition indication.
The functionality of the system can be destroyed in the case of
incorrect use.
If unauthorized changes have been made to delivered system and
accessories, the warranty by 3D Imaging & Simulations Corp.
becomes void. 3D Imaging & Simulations Corp. will not accept
any responsibility or liability for the proper functioning of the
product in such a case.
DANGER
General mandatory action manual.
The functionality of the system can be destroyed in the case of
incorrect use.
If unauthorized changes have been made to delivered system and
accessories, the warranty by 3D Imaging & Simulations Corp.
becomes void. 3D Imaging & Simulations Corp. will not accept
any responsibility or liability for the improper functioning of the
product in such a case.
WARNING
The functionality of the system can be limited in the case of
incorrect use. Hints that require special attention.
NOTE
Notes represent information that is important to know but which do
not affect the functionality of the system.
4
User Manual
FireCR Flash TM-401-EN
All the safety and operating instructions should be read carefully before this device is operated.
This device has been designed and tested to meet strict safety requirements applicable to
medical equipment, and has been supplied in a safe condition. To ensure personnel and
patient safety, the device shall be operated and serviced in compliance with all procedures,
warnings and precautions during all phases of operation and service of this device. Failure to
comply to with safety guidelines may result in injury to service personnel, operator, or patient.
3D Imaging & Simulations Corp. assumes no liability for failure to comply.
If this device is not used as specified, the protection provided by the device could be impaired.
This device must be used in a normal condition only.
Installation, service and operation of this device should only be undertaken by qualified trained
personnel. The operator should study instructions and precautions carefully before starting to
use the device listed here and throughout the manual.
There are no user serviceable parts inside this device. The device should only be opened and
serviced by qualified service personnel. Failure to heed this warning may result in injury to
service personnel or damage to equipment, and void any and all warranties. If there is a
service problem, please contact 3D Imaging & Simulations Corp. or authorized dealer.
Do not spill liquids on the device, and never operate the device in a wet environment.
Use the device only with accessories supplied with this device.
This device is intended to be grounded. Plug power cord into properly grounded electrical
outlets. This cord is equipped with three-prong plugs to help ensure proper grounding.
This device contains static sensitive components. Proper static handling procedures and
equipment must be used when servicing this device.
5
User Manual
FireCR Flash TM-401-EN
If any of the following conditions occur, unplug the device from the electrical outlet and contact
authorized service personnel.
The power cord or power adapter is damaged.
An object has fallen into the device.
The device has been exposed to water.
The device has been dropped or damaged.
The device does not operate correctly when the operating instructions are followed.
Intended Use
This device is a Computed Radiography System and intended for use in producing digital X-Ray
images for general radiography purposes. It comprises of reader, cassette with reusable
imaging plate and workstation software. It scans X-Ray exposed image plate and produces X-
Ray image in digital form. Then, digital image is transferred to workstation for further
processing and routing. This device is intended to be operated in a radiological environment
by qualified staff.
FireCR Flash is not approved for the acquisition of mammographic image data.
6
User Manual
FireCR Flash TM-401-EN
Index of contents
Chapter 1. Introduction .................................................................... 9
7
User Manual
FireCR Flash TM-401-EN
8
User Manual
FireCR Flash TM-401-EN
Chapter 1. Introduction
Thank you very much for deciding on FireCR Flash – Computed Radiography Reader.
The FireCR Flash System is ideal for a wide range of Computed Radiography examinations in
specialty practices such as chiropractors, podiatrists and orthopedists.
The FireCR Flash can be configured for nearly every clinical application, and is designed for full
DICOM connectivity, and allows user to setup the system to capture high quality X-ray images
of any body parts with minimal steps including reading, processing, displaying and sending of
the high quality image. All imaging parameters are optimized, resulting in digital images that
can be enhanced, enlarged, duplicated, and sent to any location as a DICOM 3.0 file format in
seconds with no loss of resolution.
Combine the system with reusable phosphor screen equipped FireCR Flash cassettes and
portable X-ray equipment, it can be used for X-ray exams everywhere it is needed, e.g. nursing
facilities, forensic institutions, employee screenings etc.
The FireCR Flash System is ideal for Computed Radiography examinations in busy clinics and
specialty practices. Affordable, rugged, compact, lightweight, fast and effective FireCR Flash
System enables all imaging functions to be performed with the advanced image management
software, a solution that can be adapted most clinical applications.
The FireCR Flash Computed Radiography solution with enhanced workflow and improved
productivity are the best solution for medium sized healthcare facilities and clinics. The FireCR
Flash System complements centralized CR and DR environments such as clinics, ER and OR
departments.
9
User Manual
FireCR Flash TM-401-EN
Main Features
High Throughput
Its unique and patented dual direction scanning mechanism enables to improve the efficiency
and high throughput.
Scanning Resolution
User selectable resolution of 100m and 200m allows user to make diagnosis on variable
purposes.
Detector
High sensitive photomultiplier tube equipped in FireCR Flash delivers high gain, wide dynamic
range and high speed response for radiographic imaging.
10
User Manual
FireCR Flash TM-401-EN
Chapter 2. Unpacking
FireCR Flash is shipped in a custom designed container to protect the reader from external
shock. Before unpacking the reader, inspect the shipping container for damage. In case the
container is damaged, notify the shipper immediately.
Optional items
Part No. Item
CR-FP-42-003 Cassette including IP 18cm x 24cm
WARNING
If the FireCR Flash needs to be returned to manufacturer or one
of its representatives, the scanner must be repacked in the
original container with all accessories.
11
User Manual
FireCR Flash TM-401-EN
WARNING
Use of Power Cord;
Type SJT or SVT, min. 18AWG, 3-Conductor, VW-1 125V, min 10A
(or 250V, 10A). Max 3.0m long; One end with Hospital Grade
Type, NEMA 5-15P for 125V or NEMA 6-15P for 250V. Other end
with appliance coupler. “CAUTION Grounding reliability can only
be achieved when the equipment is connected to an equipment
receptacle marked “Hospital Only” or “Hospital Grade”.
For connection to supply not in USA, make sure the power cord is
the correct type that is required in your area.
WARNING
Improper disposal of this product may result in environmental
contamination. When disposing of this equipment, contact 3D
Imaging & Simulations Corp.’s representative or related organs
of government. Do not dispose of any part of this equipment
without consulting a 3D Imaging & Simulations Corp.’s
representative first.
WARNING
Use the device passed IEC60950-1 or IEC60601-1 for the product
connected via USB port.
12
User Manual
FireCR Flash TM-401-EN
Chapter 3. Setting Up
WARNING
Unsuitable Installation Sites
Locations with excessive humidity or dust
Locations subject to high temperature
Locations subject to shaking or vibration
Locations exposed to considerable electrical or magnetic
noise, or other forms of electromagnetic energy
Locations with poor heat radiation
The reader must be placed on a rigid and flat desk or tabletop with at least 10 cm (4 inch) free
space on both sides, 20 cm (8 inch) on rear side and 50 cm (20 inch) on front side for cassette
insertion. Its space requirements are shown below.
In case that desk or table is not flat, adjust feet under the reader for leveling. The reader
weighs approximately 19.5 kg (42.4 lbs) and requires two persons to lift. Carefully place the
reader into its final position.
Free space of 20 cm (8
13
User Manual
FireCR Flash TM-401-EN
DANGER
Never place the reader on the floor.
WARNING
Sliding the reader may result in internal damage or misalignment
of the optics.
DANGER
Do not place anything on top of the scanner.
WARNING
This equipment may be interfered or interfere by electromagnetic
or other interference.
The FireCR Flash can be mounted on the wall to save space occupancy. When purchasing
the wall mount kit, a detailed installation guide and all parts necessary for assembly are
provided.
14
User Manual
FireCR Flash TM-401-EN
Front Side
Free space of 10 cm
(4 inch) on both
sides, at least.
Back Side
DANGER
Only authorized or trained personnel should set wall mount
installation.
NOTE
Refer to Wall Mount Installation Guide provided with Wall Mount
Installation Kit.
15
User Manual
FireCR Flash TM-401-EN
DANGER
Install the wall mount on a solid wall perpendicular to the floor.
When attaching to other building materials, please contact your
local dealer. If installed on a slanted wall, it may fall and result in
severe injury.
DANGER
3D Imaging & Simulations Corp. is not liable for product damage or
personal injury when the user fails to follow the product installation
instruction.
WARNING
Pulling, pushing, or climbing on the system may cause the system
fall.
Look over the reader and features shown in this section. User will need to know where these
features are when user operates the reader in later chapters.
16
User Manual
FireCR Flash TM-401-EN
LED
Status Remark
Green Blue
On System On
Cassette is in initial position, and
On Ready to Scan
ready to scan.
Blinking Scanning
Blinking Erasing
Blinking Blinking Error
WARNING
Do not push scanner reset button during scanning.
17
User Manual
FireCR Flash TM-401-EN
18
User Manual
FireCR Flash TM-401-EN
DANGER
This equipment is indoor use only and all the communication
wirings are limited to inside of the building.
WARNING
Do not pull out the USB / Ethernet cable during scanning.
DANGER
This equipment must only be connected to supply mains with
protective earth. Use only a three-wire cord that has grounding.
This is a safety feature. If you are unable to insert the plug into
the outlet, contact your electrician to replace your obsolete outlet.
Do not defeat the safety purpose of the grounding-type plug.
DANGER
Do not use any power cord other than the power cord included
with the system. Doing so may lead to fire, electrical shock, or
electrocution.
WARNING
Socket-outlet shall be installed near the device and shall be easily
accessible.
Do not unplug the power cord or turn the power switch off during
scanning.
19
User Manual
FireCR Flash TM-401-EN
Fax : +82-42-931-2299
E-mail : [email protected]
20
User Manual
FireCR Flash TM-401-EN
Chapter 4. Operating
Standard 200um
Sampling Pixel Pitch
High 100um
Standard 1750 x 2150
Pixel Matrix (IP 35cm x 43cm)
High 3500 x 4300
Standard 1200 x 1500
Pixel Matrix (IP 24cm x 30cm)
High 2400 x 3000
Standard 900 x 1200
Pixel Matrix (IP 18cm x 24cm)
High 1800 x 2400
35cm x 43cm, 24cm x 30cm, 18cm x
Accepted Cassette Size
24cm
AD Convert Resolution 16 bit
Eraser Embedded
Computer Interface USB 2.0 / Ethernet
456 x 803 x 137mm
Dimensions
17.9 x 31.6 x 5.4inch
19.5kg
Weight
42.4lbs
Power Requirement 100 ~ 240V / 50 ~ 60Hz
System Configuration Tabletop or Wall Mount
Image File Format DICOM 3.0
21
User Manual
FireCR Flash TM-401-EN
DANGER
There are no user serviceable parts inside the reader. The
reader should only be opened and serviced by qualified service
personnel. Failure to heed this warning may result in injury to
service personnel or damage to equipment, and void any and all
warranties. If there is a service problem, please contact 3D
Imaging & Simulations Corp. or authorized dealer.
22
User Manual
FireCR Flash TM-401-EN
DANGER
This device uses laser. Avoid looking inside of the scanner.
Cassette can be ejected when scanning and erasing are completed. Gently pull back the
cassette and ejection direction of the cassette must be parallel to the reader.
WARNING
Do not insert the cassette in wrong direction or upside down when
it is being inserted. Cassette insertion direction is marked on the
cassette.
23
User Manual
FireCR Flash TM-401-EN
Power Board :
Power board generated DC Power of +15V, -15V, +5V
Main Board :
This parts controls peripherals for image acquisition. And it delivers amplified digitized
signal to PC via USB or Ethernet.
Driver Board :
This parts controls peripherals for PSD peak detect, Eraser control, high voltage
generation
BLDC Board :
This parts controls BLDC Motor and square mirror spin
RFID Board :
This part communicates with the RFID tag. RFID tag is contain IP Cassette information
Peripheral :
This is peripherals for image acquisition. It consists of “Eraser” which erases residual
images in imaging plate, “Step Motor and Interrupters” which moves stage, “Laser,
Mirror and DC Motor” which are required to radiate laser onto imaging plate, “DC
Motor” which assures proper insertion of the cassette.
24
User Manual
FireCR Flash TM-401-EN
Chapter 5. Symbols
Symbol Description
.Manufacturer
Date of Manufacture
Equipment Power ON
Keep Dry
25
User Manual
FireCR Flash TM-401-EN
Fragile
This side up
FCC ID :
FCC Mark
X68CRSCANNER5
Medical Equipment
WITH RESPECT TO ELECTRIC SHOCK
FIRE, AND MECHANICAL HAZARDS ONLY
IN ACCORDANCE WITH UL60601-1 / CAN / CSA CSS.2 No. 601.1
3SE3
CE Mark
26
User Manual
FireCR Flash TM-401-EN
27
User Manual
FireCR Flash TM-401-EN
Recommended separation
distance
Note 1) Uт is the A.C. mains voltage prior to application of the test level.
Note 2) At 80 MHz and 800 MHz, the higher frequency range applies.
Note 3) These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
28
User Manual
FireCR Flash TM-401-EN
a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and
land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted
theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an
electromagnetic site survey should be considered. If the measured field strength in the location in which the
EUT is used exceeds the applicable RF compliance level above, the EUT should be observed to
verifynormal operation. If abnormal performance is observed, additional measures may be necessary, such
as re-orienting or relocating the EUT.
b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than [V1] V / m.
Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected
by absorption and reflection from structures, objects, and people.
29
User Manual
FireCR Flash TM-401-EN
Electromagnetic Immunity
The FireCR Flash system is intended for use in the electromagnetic environment specified below.
The customer or the user of FireCR Flash system should assure that it is used in such an
environment
IEC 60601 Electromagnetic environment -
Immunity test Compliance level
Test level guidance
Conducted RF 3 Vrms 3 Vrms FireCR Flash system must be used
IEC 61000-4-6 150 kHz to 80MHz 150 kHz to 80 MHz only in a shielded location with a
minimum RF shielding effectiveness
and, for each cable that enters the
shielded location with a minimum RF
shielding effectiveness and, for each
cable that enters the shielded location
Radiated RF 3 V/m 3 V/m Field strengths outside the shielded
IEC 61000-4-3 80.0 MHz to 2.5GHz 80.0 MHz to 2.5GHz location from fixed RF transmitters, as
determined by an electromagnetic site
survey, should be less than 3V/m.a
Note 1) These guidelines may not apply in all situations. Electromagnetic propagation is affected
by absorption and reflection from structures, objects and people.
Note 2) It is essential that the actual shielding effectiveness and filter attenuation of the shielded
location be verified to assure that they meet the minimum specification.
a- Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless)
telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast
cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to
fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field
strength outside the shielded location in which the EUT is used exceeds 3V/m, the EUT should be
observed to verify normal operation.
If abnormal performance is observed, additional measures may be necessary, such as relocating
the EUT or using a shielded location with a higher RF shielding effectiveness and filter attenuation.
30
User Manual
FireCR Flash TM-401-EN
The Computed Radiography Reader is Certified in the U.S. to Conform to the Requirements of
DHHS 21 CFR, chapter 1 Subchapter J for Class I(1) Laser Products, and Elsewhere is
Certified as a Class I(1) Laser Product Conforming to the Requirements of IEC 60825-1 :
2007. Class I(1) Laser Products are not Considered to be Hazardous. The Laser System and
Computed Radiography Reader are Designed so there is never any Human Access to Laser
Radiation above a Class I(1) level during normal Operation, user Maintenance or Prescribed
Service Condition.
WARNING
Never operate or service the product with the protective cover removed
from Laser/Reader assembly.
The reflected beam, although invisible, can damage your eyes.
When using this product, these basic safety precautions should always be
followed to reduce risk of fire, electric shock and personal injury
Warning
Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure
31
User Manual
FireCR Flash TM-401-EN
3D Imaging & Simulations Corp. warrants its non-consumable hardware products to be free
from defects in materials and workmanship. The warranty covers the cost of parts and labor to
repair the product. Please keep the shipping container for future use. Products returned to
the factory for repair should be properly packaged. To obtain warranty service, follow the
procedure described in the Repair Service section. Failure to do so will cause long delays and
additional expense to the customer.
The warranty is valid when the product is used for its intended purpose and does not cover
products which have been modified without written permission from 3D Imaging & Simulations
Corp., or which have been damaged by abuse, accident or connection to incompatible
equipment.
Out of warranty repair service is available in selected geographical locations. Contact the
supplier for current terms and rates.
32
User Manual
FireCR Flash TM-401-EN
6.4. Shipping
The FireCR Flash is a solidly built system designed to survive shipping around the world.
However, in order to avoid damage during shipping, the FireCR Flash must be properly
packaged.
In general, the best way to package the FireCR Flash is in the original factory container. If this
is no longer available, we recommend that user carefully wraps the FireCR Flash in at least 75
mm (3 inch) of foam or bubble pack sheeting. The wrapped device should then be placed in a
sturdy cardboard carton. Mark the outside of the box with word FRAGILE and an arrow
showing which way is up.
We do not recommend using loose foam pellets to protect the FireCR Flash. If the carton is
dropped by the shipper, there is a good chance that the device will shift within the loose pellet
packing and be damaged.
If user needs to ship the FireCR Flash to another location, or back to the factory, and user does
not have a means to adequately package it, user can order additional shipping container. This
may seem an expense user would like to avoid, but it is inexpensive compared to the cost of
repairing an instrument that has sustained shipping damage.
It is user’s responsibility to package the system properly before shipping. If the packaging is
inadequate, and the system is damaged during shipping, the shipper will not honor user’s claim
for compensation.
33
User Manual
FireCR Flash TM-401-EN
34
User Manual
FireCR Flash TM-401-EN
Appendix I
Installation Report
Please complete this report at the time of installation and submit the
completed form signed by customer to:
Fax : +82-42-931-2299
E-mail : [email protected]
Date of Installation :
Customer Information
Hospital / Institute
Name
Address
Tel
Fax
E-mail
Installer Information
Company
Name
Address
Tel
Fax
E-mail
System Information
Model FireCR Flash CR Reader
System S/N
35