Finder Series88

The 88 Series plug-in timers offer multi-voltage and multi-function options with time scales ranging from 0.05 seconds to 100 hours, and configurations for both delayed and instantaneous contacts. They are compatible with 90 series sockets and come in 8 or 11 pin versions, featuring various functions such as ON delay and pulse. The timers are designed for a wide range of applications with specific electrical and mechanical specifications, including rated currents and voltages.

Uploaded by

reyma.a24
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views6 pages

Finder Series88

The 88 Series plug-in timers offer multi-voltage and multi-function options with time scales ranging from 0.05 seconds to 100 hours, and configurations for both delayed and instantaneous contacts. They are compatible with 90 series sockets and come in 8 or 11 pin versions, featuring various functions such as ON delay and pulse. The timers are designed for a wide range of applications with specific electrical and mechanical specifications, including rated currents and voltages.

Uploaded by

reyma.a24
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

88 Series - Plug-in timers 5 - 8 A

Features 88.02 88.12


Multi-voltage and multi-function timer range
Front panel or socket mount
• 8 - 11 pin plug-in version available
• Time scales from 0.05s to 100h
• “1 delayed contact +1 instantaneous
contact” version available (type 88.12)
• Front panel mounting fixing included
• 90 series sockets

• Multi-function
• Multi-function
• 8 pin, 2 timed contacts or
• 11 pin
1 timed + 1 instantaneous contact
48 • Plug-in for use with 90 series sockets
• Plug-in for use with 90 series sockets

AI: ON delay Al a: ON Delay (2 timed contacts)


DI: ON pulse Al b: ON Delay (1 timed + 1 instantaneous contact)
48

GI: Fixed pulse (0.5s) delayed Dl a: ON Pulse (2 timed contacts)


SW: Symmetrical recycling: ON start Dl b: ON Pulse (1 timed + 1 instantaneous contact)
without signal START GI: Fixed pulse (0.5s) delayed
A2 A1 22 21 24 32 31 34 12 11 14 SW: Symmetrical recycling.
37
10 2 5 6 7 8 11 9 4 1 3
9
16

P R without signal START


L/+ U N/–
79.5

A1 A2 12 11 14 22 21 24
BE: Signal OFF delay
94

2 7 4 1 3 5 8 6
CE: Signal ON and OFF delay
DE: Signal ON pulse
N/– L/+ C1 C2
with signal START U
A2 A1 22 21 24 32 31 34 12 11 14
10 2 5 6 7 8 11 9 4 1 3
44.5

P = Pause
P S R S = Start
L/+ U N/– R = Reset
Contact specification
Contact configuration 2 CO (DPDT) 2 CO (DPDT)
Rated current/Maximum peak current A 8/15 5/10
Rated voltage/Maximum switching voltage V AC 250/250 250/400
Rated load AC1 VA 2,000 1,250
Rated load AC15 (230 V AC) VA 400 250
Single phase motor rating (230 V AC) kW 0.3 0.125
Breaking capacity DC1: 30/110/220 V A 8/0.3/0.12 5/0.3/0.12
Minimum switching load mW (V/mA) 300 (5/5) 500 (5/5)
Standard contact material AgNi AgCdO
Supply specification
Nominal voltage (UN) V AC (50/60 Hz) 24…230 24…230
V DC 24...230 24...230
Rated power AC/DC VA (50 Hz)/W 2.5 (230 V)/1 (24 V) 2.5 (230 V)/1.5 (24 V)
Operating range AC 20.4…264.5 20.4…264.5
DC 20.4…264.5 20.4…264.5
Technical data
Specified time range (0.05 s…5 h) - (0.05 s…10 h) - (0.05 s…50 h) - (0.05 s…100 h)
Repeatability % ±1 ±1
Recovery time ms 300 200
Minimum control impulse ms 50 —
Setting accuracy-full range % ±3 ±3
Electrical life at rated load AC1 cycles 100·103 100·103
Ambient temperature range °C –10…+55 –10…+55
Protection category IP 40 IP 40
Approvals (according to type)
1
88 Series - Plug-in timers 5 - 8 A

Ordering information
Example: 88 series multi-function timer, 2 CO (DPDT) contact 8 A, (24…230)V AC (50/60 Hz) and (24…230)V DC supply.

8 8 . 0 2 . 0 . 2 3 0 . 0 0 0 2
Series Special versions
2 = Standard
Type
0 = Functions AI, DI, GI, SW, BE, CE, DE, 11 pin Supply voltage
1 = Functions Al a, Al b, Dl a, Dl b, GI, SW, 8 pin 230 = (24…230)V AC/DC
No. of poles
2 = 2 pole
Supply version
0 = AC (50/60 Hz)/DC

Technical data
EMC specifications
Type of test Reference standard
Electrostatic discharge contact discharge EN 61000-4-2 4 kV
air discharge EN 61000-4-2 8 kV
Radio-frequency electromagnetic field (80 ÷ 1000 MHz) EN 61000-4-3 10 V/m
Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals EN 61000-4-4 2 kV
Surges (1.2/50 µs) on Supply terminals common mode EN 61000-4-5 2 kV
differential mode EN 61000-4-5 1 kV
Radio-frequency common mode (0.15 ÷ 80 MHz) EN 61000-4-6 3V
on Supply terminals

Selection of: function, time scale and units


88.02 88.12
E Function selector AI, DI, GI, SW, BE, CE, DE Al a, Al b, Dl a, Dl b, GI, SW
D Time scale selector 0.5, 1, 5, 10
H Unit of time selector s (second), min (minute), h (hour), 10h (10 hour)

Time scales
Full scale value

D H s min h x10h A E
0.5
B
0.5 second 0.5 minute 0.5 hour 5 hour F
1 1 second 1 minute 1 hour 10 hour
5 5 second 5 minute 5 hour 50 hour
10 10 second 10 minute 10 hour 100 hour G
NOTE: time scales and functions must be set before energising the timer.
C
D H

LED/visual indication
A Yellow LED: power ON (U)
B Red LED: timing in progress (C)
C Unit of time selected
F Function selected
G Time selected

2
88 Series - Plug-in timers 5 - 8 A

Functions
U =Supply
LED LED Supply NO output Contact
Voltage
(yellow) (red) voltage contact Open Closed
S =Signal
switch OFF Open x1 - x4 x1 - x2

P =Pause ON x1 - x4 x1 - x2
Open
x1 - x2 x1 - x4
R = Reset Open (timing
ON x1 - x4 x1 - x2
in progress)
= Output ON Closed x1 - x2 x1 - x4
Contact

Wiring diagram Type 88.02

without signal START U (AI) ON delay.


Apply power to timer. Output contacts transfer after preset time
A2 A1 22 21 24 32 31 34 12 11 14
T t<T has elapsed. Reset occurs when power is removed.
10 2 5 6 7 8 11 9 4 1 3

U (DI) ON pulse.
P R Apply power to timer. Output contacts transfer immediately.
L/+ U N/– After the preset time has elapsed, contacts reset.
T t<T

U (GI) Fixed pulse (0.5s) delayed.


Apply power to timer. Output contacts transfer after preset
T 0.5s time has elapsed. Reset occurs after a fixed time of 0.5s.

U (SW) Symmetrical recycling: ON start.


Apply power to timer. Output contacts transfer immediately
T T T T t<T and cycle between ON and OFF for as long as power is
applied. The ratio is 1:1 (time on = time off).

with signal START U (BE) Signal OFF delay.


S Power is permenently applied to the timer.
A2 A1 22 21 24 32 31 34 12 11 14
The output contacts transfer immediately on closure of the
10 2 5 6 7 8 11 9 4 1 3 T T T t<T
T Signal Switch (S). Opening the Signal Switch initiates the
preset delay, after which time the output contacts reset.
P S R
L/+ U N/– U
(CE) Signal ON and OFF delay.
S
Power is permenently applied to the timer.
Closing the Signal Switch (S) initiates the preset delay, after
T T which time the output contacts transfer. Opening the Signal
T T T T
switch initiates the same preset delay, after which time the
output contacts reset.

U (DE) Signal ON pulse.


S Power is permenently applied to the timer.
On momentary or maintained closure of Signal Switch (S),
T T t<T the output contacts transfer, and remain so for the duration
of the preset delay, after which they reset.

RESET (R) PAUSE (P)


A momentary closure of the reset switch (2-7) will reset the timer. Longer Closure of the pause switch (2-5) will immediately halt the timing process,
term closure of the reset switch will hold the timer in the reset state. This but the elapsed time will be retained, and the current state of the output
is applicable for all functions. contacts will be maintained.
On opening of the pause switch, timing resumes from the retained value.
This is applicable for all functions.

3
88 Series - Plug-in timers 5 - 8 A

Functions
Wiring diagram Type 88.12

without signal START U (Al a) ON Delay (2 timed contacts).


A1 A2 12 11 14 22 21 24 C1 Apply power to timer.
2 7 4 1 3 5 8 6 C2 Contacts (C1 and C2) transfer after preset time has elasped.
T Reset occurs when power is removed.
N/– L/+ C1 C2
U
U (Al b) ON Delay
C1 (1 timed contact + 1 instantaneous contact).
C2 Apply power to timer. Output contact (C1) transfers immediately.
T Contact (C2) transfers after the preset time has elasped. Reset
occurs when power is removed.

U (Dl a) ON pulse (2 timed contacts).


C1 Apply power to timer.
C2 Output contacts (C1 and C2) transfer immediately.
T After preset time has elasped, the contacts reset.

U (Dl b) ON pulse (1 timed contact + 1 instantaneous contact).


C1 Apply powert to timer. Output contacts (C1 and C2) transfer
C2 immediately. After preset time has elasped, the contact (C2)
T resets. Contact (C1) resets when power is removed.

U (GI) Fixed pulse (0.5s) delayed.


C1 Apply power to timer. Output contacts transfer after preset time
C2 has elapsed. Reset occurs after a fixed time of 0.5s.
T 0.5s

U (SW) Symmetrical recycling.


C1 Apply power to timer. Output contacts transfer immediately
C2
and cycle between ON and OFF for as long as power is applied.
T T T T t<T The ratio is 1:1 (time on = time off).

4
90 Series - Sockets and Accessories for 88 series Timers

Screw terminal (Box clamp) socket 90.20 90.20.0 90.21 90.21.0


panel or 35 mm rail (EN 50022) mount Blue Black Blue Black
For timer type 88.12 88.02
Technical data
Rated values 10 A - 250 V
90.21
Dielectric strength 2 kV AC
Approvals Protection category IP 20
(according to type):
Ambient temperature °C –40…+70
Screw torque Nm 0.5
Wire strip length mm 10
Max. wire size for 90.20 and 90.21 sockets solid wire stranded wire
mm2 1x6 / 2x2.5 1x6 / 2x2.5
AWG 1x10 / 2x14 1x10 / 2x14
NO NC NC NO NO NC NO NC NO NC
24 22 12 14 34 32 24 22 14 12
6 5 4 3 9 8 7 5 3 4

14
67
67

35
3.2

3.2
27.5
27.5

18
A2 21 11 A1 A2 31 21 11 A1
7 8 1 2 10 11 6 1 2
COIL COM COM COIL 30 COIL COM COM COM COIL 30 22
38 38 25.5
90.20 90.21

Screw terminal (Plate clamp) socket 90.26 90.26.0 90.27 90.27.0


panel or 35 mm rail (EN 50022) mount Blue Black Blue Black
For timer type 88.12 88.02
Technical data
Rated values 10 A - 250 V
90.26
Dielectric strength 2 kV AC
Approvals Protection category IP 20
(according to type):
Ambient temperature °C –40…+70
Screw torque Nm 0.8
Wire strip length mm 10
Max. wire size for 90.26 and 90.27 sockets solid wire stranded wire
mm2 1x4 / 2x2.5 1x4 / 2x2.5
AWG 1x12 / 2x14 1x12 / 2x14
NO NC NC NO NC NO com NC
24 22 12 14 33 20 32 24 21 22 35
6 5 4 3 8 7 6 5
6

NC
=

12
4
4.2

35

56

35
51

4.2

34 14
25.5

28

9 3
NO NO
10

A2 21 11 A1 A2 31 11 A1
7 8 1 2 10 11 1 2 27.6
COIL COM COM COIL 41 23 COIL COM COM COIL 43 31

90.26 90.27

Sockets 8-11 pin backwired with solder terminals 90.12.4 (black) 90.13.4 (black)
For timer type 88.12 88.02
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
90.13.4
Ambient temperature °C –40…+70
Approvals
(according to type): 32.5
Ø 31

31 31

90.12.4 90.13.4