0% found this document useful (0 votes)
46 views69 pages

RC Design U 2022 v12.6

The document is a comprehensive guide on Reinforced Concrete Design using the Ultimate Limit Design Method according to ECP 203-2017, authored by Dr. Mahmoud M. El-Kateb. It covers various aspects of structural engineering, including calculations for sections, loads, fire rating requirements, and design specifications for slabs, beams, columns, and foundations. The document serves as a tool for engineers to ensure compliance with design standards and improve structural integrity.

Uploaded by

Ahmed Saeed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views69 pages

RC Design U 2022 v12.6

The document is a comprehensive guide on Reinforced Concrete Design using the Ultimate Limit Design Method according to ECP 203-2017, authored by Dr. Mahmoud M. El-Kateb. It covers various aspects of structural engineering, including calculations for sections, loads, fire rating requirements, and design specifications for slabs, beams, columns, and foundations. The document serves as a tool for engineers to ensure compliance with design standards and improve structural integrity.

Uploaded by

Ahmed Saeed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 69

INDEX (Quick reach)

Reinforced Concrete Design©


Using the Ultimate Limit Design Method
according to the ECP 203-2017

Ver. 12.6

Please send your comments & suggestions to improve this tool on


[email protected]

by
Mahmoud M. El-Kateb, Ph.D

Structural Engineering Dept.


Faculty of Engineering - Ain Shams University
GENERAL
Calculation of T & L Section Inertia
Calculation of Loads and Coefficients
Fire Rating Requirements
Capacity of Sections

SLABS
Empirical Analysis of Solid Slabs
Design of Slabs
Empirical Design of Flat Slab
Check Punching for Flat Slab Columns
Calculation of Punching RFT

DEEP BEAMS
Design of Simple Deep Beams
Design of Continuous Deep Beams
Design of Corbel

SERVICEABILITY
Deflection of Cantilever
Deflection of Simple R-Section
Deflection of Simple T-Section
Calculation of Crack Width

Design of Retaining Walls

Design of Water Section


BEAMS
Design of Beams
Design of Beams with Compression RFT
Design of Sec. under M & N
Check Shear in Beams
Design of Torsion

COLUMNS
Design of Rectangular Columns
Design of Circular Columns

FOUNDATIONS
Design of Isolated Footing
Design of isolated Footing under Moment
Design of isolated Footing under Double Moment
Design of Fence Footing
Design of Combined Footing
Design of Strap Beam Footing
Design of Pile Cap
Design of Pile Cap under Moment
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 1.2

* Calculation of T & L Section Inertia

* Project :

1200 mm
250 mm

700 mm

300 mm

I R-sec = 8.58E+09 mm4


yc.g = 234 mm from flange edge
I T-sec = 1.52E+10 mm4 = 1.8 I R-sec
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 9.5

* Calculation of Loads & Coefficients

* Project :

Load Distribution of Solid Slabs:

Long span Short span Code of practice Marcus Grashoff


Area
Span (m) contin. Span (m) contin. a b a b a b
1 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
2 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
3 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
4 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
5 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
6 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
7 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
8 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
9 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291
10 5 1 4 1 0.475 0.224 0.568 0.232 0.709 0.291

Load Distribution on Beams:

Load on Long Short Load coeff. Load distribution for


Area
slab (kN/m2) span (m) span (m) shear moment shear (kN/m`) moment (kN/m`)
1 8.5 5 4 0.600 0.787 10.2 13.4
2 8.5 5 4 0.600 0.787 10.2 13.4
3 8.5 5 4 0.600 0.787 10.2 13.4
4 8.5 5 4 0.600 0.787 10.2 13.4
5 8.5 5 4 0.600 0.787 10.2 13.4
6 8.5 5 4 0.600 0.787 10.2 13.4
7 8.5 5 4 0.600 0.787 10.2 13.4
8 8.5 5 4 0.600 0.787 10.2 13.4
9 8.5 5 4 0.600 0.787 10.2 13.4
10 8.5 5 4 0.600 0.787 10.2 13.4

Load of Hollow Slabs:

Web breadth Spacing Thick Slab th F.C L.L Block One way Two way
Area
b (mm) e (mm) t (mm) ts (mm) (kN/m ) (kN/m ) Wt. (kN)
2 2
Wu (kN/m2) Wu (kN/m2)
1 120 400 270 70 1.5 2.0 0.15 11.4 12.2
2 120 400 270 70 1.5 2.0 0.15 11.4 12.2
3 120 400 270 70 1.5 2.0 0.15 11.4 12.2
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 9.5

* Calculation of Loads & Coefficients

* Project :

4 120 400 270 70 1.5 2.0 0.15 11.4 12.2


5 120 400 270 70 1.5 2.0 0.15 11.4 12.2
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 1.0

* Fire Rating Requirements

* Project :

Design fire rating period: 2 hours


Type of aggregate: ‫متوسط الوزن‬

Traditional slabs: Pre-stressed slabs:


min. Thick = 120 mm min. Cover = 40 mm
min. Cover = 25 mm

Traditional simple beams: Traditional cont. beams:


min. Breadth = 250 mm min. Breadth = 180 mm
min. Cover = 35 mm min. Cover = 30 mm

Columns:
min. Dim. = 250 mm
min. Cover = 40 mm

Walls:
RFT ratio m 0.4 % < < 1 %
min. Dim. = 200 mm
min. Cover = 25 mm
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 1.0

* Capacity of Sections

* Project :

Concrete fcu = 25 MPa

Steel fy = 400 MPa


###
###
Breadth Thick Depth Tension RFT As Comp. RFT As` Moment
Sec. Comp. RFT case
b (mm) t (mm) d (mm) no. f (mm ) 2
no. f (mm2) capacity (kN.m)
1 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
2 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
3 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
4 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
5 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
6 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
7 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
8 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
9 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
10 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
11 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
12 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
13 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
14 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
15 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
16 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 1.0

* Capacity of Sections

* Project :

Concrete fcu = 25 MPa

Steel fy = 400 MPa


###
###
Breadth Thick Depth Tension RFT As Comp. RFT As` Moment
Sec. Comp. RFT case
b (mm) t (mm) d (mm) no. f (mm ) 2
no. f (mm2) capacity (kN.m)
17 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
18 1000 220 190 6 12 679 6 10 471 Ignore comp. RFT 42.4
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Empirial Analysis of Solid Slabs

* Project :

Concrete fcu = 25 MPa

Steel fy = 400 MPa

Long span Short span min. Slab Slab thick F.C L.L Wsu Code of practice Moments (kN.m) Rft. /m Rft. /m
Area
Span (m) contin. Span (m) contin. thick (mm) (mm) (kN/m 2
) (kN/m 2
) (kN/m 2
) a b Ma Mb short dir. long dir.
1 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
2 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
3 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
4 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
5 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
6 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
7 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
8 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
9 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
10 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
11 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
12 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
13 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
14 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
15 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
16 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
17 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Empirial Analysis of Solid Slabs

* Project :

Concrete fcu = 25 MPa

Steel fy = 400 MPa

Long span Short span min. Slab Slab thick F.C L.L Wsu Code of practice Moments (kN.m) Rft. /m Rft. /m
Area
Span (m) contin. Span (m) contin. thick (mm) (mm) (kN/m 2
) (kN/m 2
) (kN/m 2
) a b Ma Mb short dir. long dir.
18 5 1 4 1 114 140 1.50 2.00 10.50 0.475 0.224 9.98 7.35 4 f 10 3 f 10
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.2

* Design of Slabs

* Project :

Concrete fcu = 25 MPa

Steel fy = 400 MPa

###
Ult. Moment Breadth Depth As Asmin Used
Sec. C1 J Rft. /m Notes
Mu (kN.m) b (mm) d (mm) (mm2) (mm2) As
1 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
2 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
3 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
4 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
5 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
6 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
7 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
8 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
9 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
10 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
11 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
12 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
13 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
14 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
15 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
16 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
17 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
18 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
19 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
20 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
21 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
22 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
23 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
24 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
25 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
26 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
27 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
28 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
29 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
30 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
31 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
32 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.2

* Design of Slabs

* Project :

Concrete fcu = 25 MPa

Steel fy = 400 MPa

###
Ult. Moment Breadth Depth As Asmin Used
Sec. C1 J Rft. /m Notes
Mu (kN.m) b (mm) d (mm) (mm2) (mm2) As
33 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
34 15 1000 120 4.90 0.826 378 180 378 5 f 10 safe
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Empirical Design of Flat Slab

* Project :

Concrete fcu = 25 MPa

Steel fy = 400 MPa

Slab Module: Long span L1 = 7 m Short span L2 = 6 m


Marginal beams: Yes
Column dim.: with long span 500 mm with short span = 500 mm
Slab thickness: 220 mm
Live load: 4.0 kN/m2 Floor cover + Walls: 2.5 kN/m2
Slab load Wsu = 17.6 kN/m2

Long direction 117.3 1 293.3 3


Column strip 4 176.0 2 146.7

Long direction 58.7 5 117.3 7


Field strip 8 117.3 6 88

Short direction 91.8 9 233.1 11 Modified


Column strip 12 134.2 10 113

Short direction 56.5 13 113.0 15 Modified


Field strip 16 113.0 14 84.8

Page 14 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Empirical Design of Flat Slab

Design of sections:

Ult. Moment Breadth Depth As Asmin Used


Sec. C1 J Rft. /m Notes
Mu (kN.m) b (mm) d (mm) (mm ) (mm )
2 2
As
1 176.0 3000 190 3.92 0.801 963 285 963 5 f 16 safe
###
2 293.3 3000 190 3.04 0.747 1722 285 1722 9 f 16 safe
###
3 146.7 3000 190 4.30 0.814 791 285 791 4 f 16 safe
###
4 117.3 3000 190 4.80 0.826 623 285 623 4 f 16 safe
###
5 117.3 3000 190 4.80 0.826 623 285 623 6 f 12 safe
###
6 117.3 3000 190 4.80 0.826 623 285 623 6 f 12 safe
###
7 88.0 3000 190 5.55 0.826 467 285 467 5 f 12 safe
###
8 58.7 3000 190 6.79 0.826 312 285 312 3 f 12 safe
###
9 134.2 3000 190 4.49 0.819 719 285 719 7 f 12 safe
###
10 233.1 3000 190 3.41 0.776 1317 285 1317 7 f 16 safe
###
11 113.0 3000 190 4.89 0.826 600 285 600 6 f 12 safe
###
12 91.8 3000 190 5.43 0.826 488 285 488 5 f 12 safe
###
13 113.0 4000 190 5.65 0.826 450 285 450 4 f 12 safe
###
14 113.0 4000 190 5.65 0.826 450 285 450 4 f 12 safe
###
15 84.8 4000 190 6.53 0.826 338 285 338 3 f 12 safe
###
16 56.5 4000 190 7.99 0.826 225 285 285 3 f 12 safe
###

Page 15 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Check Punching for Flat Slab Columns

* Project :

Concrete fcu = 25 MPa

Internal columns:

b critical perimeter (bo)

Ult. Load Col. Dims. Slab Cover Critical bo qcpu qpu


Col. Notes
Qu (kN) b (mm) t (mm) Thick (mm) (mm) Perimeter (mm) (N/mm ) 2
(N/mm2)
1 1450 500 610 450 20 Manual 3037 1.29 1.28 Safe
2 1200 500 610 400 20 Auto 3037 1.29 1.20 Safe
3 1100 500 610 400 20 Auto 3037 1.29 1.10 Safe
4 600 300 600 250 30 Auto 3037 1.29 1.03 Safe
5 600 300 600 250 30 Auto 2680 1.29 1.17 Safe
6 600 300 600 250 30 Auto 2680 1.29 1.17 Safe
7 600 300 600 250 30 Auto 2680 1.29 1.17 Safe
8 600 300 600 250 30 Auto 2680 1.29 1.17 Safe
9 600 300 600 250 30 Auto 2680 1.29 1.17 Safe

D critical perimeter (bo)

Ult. Load Col. Dims. Slab Cover Critical bo qcpu qpu


Col. Notes
Qu (kN) D (mm) Thick (mm) (mm) Perimeter (mm) (N/mm ) 2
(N/mm2)
1 450 400 250 30 Auto 1948 1.29 1.21 Safe
2 450 400 250 30 Auto 1948 1.29 1.21 Safe
3 450 400 250 30 Auto 1948 1.29 1.21 Safe

Page 16 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Check Punching for Flat Slab Columns


4 450 400 250 30 Auto 1948 1.29 1.21 Safe

Edge columns:

b
critical perimeter (bo)

Ult. Load Col. Dims. Slab Cover Critical bo qcpu qpu


Col. Notes
Qu (kN) b (mm) t (mm) Thick (mm) (mm) Perimeter (mm) (N/mm ) 2
(N/mm2)
1 390 20 900 200 25 Auto 1290 0.67 2.25 Unsafe
###
2 300 300 600 250 30 Auto 1640 1.29 1.08 Safe
###
3 300 500 600 250 30 Auto 2040 1.29 0.87 Safe
###
4 300 300 600 250 30 Auto 1640 1.29 1.08 Safe
###
5 300 300 600 250 30 Auto 1640 1.29 1.08 Safe
###
6 300 300 600 250 30 Auto 1640 1.29 1.08 Safe
###
7 300 300 600 250 30 Auto 1640 1.29 1.08 Safe
###

Corner columns:

b
critical perimeter (bo)

Ult. Load Col. Dims. Slab Cover Critical bo qcpu qpu


Col. Notes
Qu (kN) b (mm) t (mm) Thick (mm) (mm) Perimeter (mm) (N/mm ) 2
(N/mm2)
1 275 800 800 600 25 Auto 2175 1.29 0.33 Safe
2 2650 800 800 600 25 Auto 2175 1.29 3.18 Unsafe
3 200 300 600 250 30 Auto 1120 1.29 1.22 Safe
4 200 300 600 250 30 Auto 1120 1.29 1.22 Safe
5 200 300 600 250 30 Auto 1120 1.29 1.22 Safe
6 200 300 600 250 30 Auto 1120 1.29 1.22 Safe
7 200 300 600 250 30 Auto 1120 1.29 1.22 Safe

Page 17 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Calculation of Punching RFT

* Project :

Concrete fcu = 25 MPa

Steel fy = 350 MPa

Internal columns:
bb

no. of bra.
parallel to b
no. of bra.
parallel to t
bt
tcol

Ult. Load Col. Dims. Slab Req. no. of Branch Spcaing bb no. of bra. bt no. of bra. no. of RFT
Col.
Qu (kN) b (mm) t (mm) Thick (mm) branches Dia. (mm) S (mm) (mm) parallel to b (mm) parallel to t Rows
1 900 300 600 250 10 12 100 250 2 250 4 3
2 900 300 600 250 10 12 100 250 2 250 4 3
3 900 300 600 250 10 12 100 250 2 250 4 3
4 900 300 600 250 10 12 100 250 2 250 4 3
5 900 300 600 250 10 12 100 250 2 250 4 3
6 900 300 600 250 10 12 100 250 2 250 4 3
7 900 300 600 250 10 12 100 250 2 250 4 3

Page 18 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Calculation of Punching RFT


8 900 300 600 250 10 12 100 250 2 250 4 3

Ult. Load Col. Dims. Slab Req. no. of Branch Spcaing b no. of no. of
Col. Notes
Qu (kN) D (mm) Thick (mm) branches Dia. (mm) S (mm) (mm) branches Rows
1 650 400 250 8 12 100 200 4 2 Safe
2 650 400 250 8 12 100 200 4 2 Safe
3 650 400 250 8 12 100 200 4 2 Safe
4 650 400 250 8 12 100 200 4 2 Safe

Edge columns:

tcol

bcol

Ult. Load Col. Dims. Slab Req. no. of Branch Spcaing bb no. of bra. bt no. of bra. no. of RFT
Col.
Qu (kN) b (mm) t (mm) Thick (mm) branches Dia. (mm) S (mm) (mm) parallel to b (mm) parallel to t Rows
1 500 300 600 250 7 12 100 250 2 250 4 4
2 500 300 600 250 7 12 100 250 2 250 4 4
3 500 300 600 250 7 12 100 250 2 250 4 4
4 500 300 600 250 7 12 100 250 2 250 4 4

Page 19 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Calculation of Punching RFT


5 500 300 600 250 7 12 100 250 2 250 4 4
6 500 300 600 250 7 12 100 250 2 250 4 4

Corner columns:

Ult. Load Col. Dims. Slab Req. no. of Branch Spcaing bb no. of bra. bt no. of bra. no. of RFT
Col.
Qu (kN) b (mm) t (mm) Thick (mm) branches Dia. (mm) S (mm) (mm) parallel to b (mm) parallel to t Rows
1 250 300 600 250 4 12 100 250 2 250 4 2
2 250 300 600 250 4 12 100 250 2 250 4 2
3 250 300 600 250 4 12 100 250 2 250 4 2
4 250 300 600 250 4 12 100 250 2 250 4 2
5 250 300 600 250 4 12 100 250 2 250 4 2
6 250 300 600 250 4 12 100 250 2 250 4 2

Page 20 of 69
By: Dr. Mahmoud El-Kateb

Notes
qpu
Safe ###
Safe ###
Safe ###
Safe ###
Safe ###
Safe ###
Safe ###

Page 21 of 69
By: Dr. Mahmoud El-Kateb

Safe ###

qpu
###
###
###
###

Notes
qpu
Safe ###
Safe ###
Safe ###
Safe ###

Page 22 of 69
By: Dr. Mahmoud El-Kateb

Safe ###
Safe ###

Notes
qpu
Safe ###
Safe ###
Safe ###
Safe ###
Safe ###
Safe ###

Page 23 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Design of Beams

* Project :

Concrete fcu = 30 MPa

Steel fy = 420 MPa

Ult. Moment Breadth Comp.fl. Depth Asmin Used


Sec. C1 J Rft. Notes
Mu (kN.m) b (mm) B (mm) d (mm) (mm2) As
1 300 800 800 320 2.86 0.728 751 3066 16 f 16 safe
###
2 25 120 120 650 7.80 0.826 144 144 2 f 12 safe
###
3 700 700 700 450 2.46 0.658 924 5626 28 f 16 unsafe
###
4 35 120 120 650 6.59 0.826 202 202 2 f 16 safe
###
5 40 120 120 650 6.17 0.826 229 229 2 f 16 safe
###
6 1000 800 800 580 2.84 0.725 1361 5658 29 f 16 safe
###
7 50 120 120 650 5.52 0.826 229 229 2 f 16 safe
###
8 55 120 120 650 5.26 0.826 229 244 2 f 16 safe
###
9 60 120 120 650 5.03 0.826 229 266 2 f 16 safe
###
10 65 120 120 650 4.84 0.826 229 288 2 f 16 safe
###
11 70 120 120 650 4.66 0.823 229 312 2 f 16 safe
###
12 75 120 120 650 4.50 0.819 229 335 2 f 16 safe
###
13 80 120 120 650 4.36 0.815 229 359 2 f 16 safe
###
14 85 120 120 650 4.23 0.812 229 384 2 f 16 safe
###
15 90 120 120 650 4.11 0.808 229 408 3 f 16 safe
###
16 95 120 120 650 4.00 0.804 229 433 3 f 16 safe
###
17 105 250 250 450 3.80 0.797 330 697 4 f 16 safe
###
18 105 120 120 650 3.81 0.797 229 483 3 f 16 safe
###
19 110 120 120 650 3.72 0.793 229 508 3 f 16 safe
###
20 115 120 120 650 3.64 0.789 229 534 3 f 16 safe
###
21 120 120 120 650 3.56 0.785 229 560 3 f 16 safe
###
22 125 120 120 650 3.49 0.781 229 586 3 f 16 safe
###
23 130 120 120 650 3.42 0.777 229 613 4 f 16 safe
###
24 135 120 120 650 3.36 0.773 229 640 4 f 16 safe
###
25 140 120 120 650 3.30 0.769 229 667 4 f 16 safe
###
26 145 120 120 650 3.24 0.764 229 695 4 f 16 safe
###
27 150 120 120 650 3.18 0.760 229 723 4 f 16 safe
###
28 155 120 120 650 3.13 0.756 229 751 4 f 16 safe
###
29 160 120 120 650 3.08 0.752 229 780 4 f 16 safe
###
30 165 120 120 650 3.04 0.747 229 809 5 f 16 safe
###
31 170 120 120 650 2.99 0.743 229 839 5 f 16 safe
###
32 175 120 120 650 2.95 0.738 229 869 5 f 16 safe
###
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Design of Beams

* Project :

Concrete fcu = 30 MPa

Steel fy = 420 MPa

Ult. Moment Breadth Comp.fl. Depth Asmin Used


Sec. C1 J Rft. Notes
Mu (kN.m) b (mm) B (mm) d (mm) (mm2) As
33 180 120 120 650 2.91 0.733 229 899 5 f 16 safe
###
34 185 120 120 650 2.87 0.729 229 930 5 f 16 safe
###
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Design of Beams with Compression Rft.

* Project :

Concrete fcu = 25 MPa

Steel fy = 400 MPa

###
Ult. Moment Breadth Depth Thick Main Comp.
Sec. Main Rft. Comp. Rft. Notes
Mu (kN.m) b (mm) d (mm) t (mm) As As
1 400 250 650 700 2090 6 f 22 339 4 f 12 ok
2 400 250 650 700 2090 6 f 22 339 4 f 12 ok
3 400 250 650 700 2090 6 f 22 339 4 f 12 ok
4 400 250 650 700 2090 6 f 22 339 4 f 12 ok
5 400 250 650 700 2090 6 f 22 339 4 f 12 ok
6 400 250 650 700 2090 6 f 22 339 4 f 12 ok
7 400 250 650 700 2090 6 f 22 339 4 f 12 ok
8 400 250 650 700 2090 6 f 22 339 4 f 12 ok
9 400 250 650 700 2090 6 f 22 339 4 f 12 ok
10 400 250 650 700 2090 6 f 22 339 4 f 12 ok
11 400 250 650 700 2090 6 f 22 339 4 f 12 ok
12 400 250 650 700 2090 6 f 22 339 4 f 12 ok
13 400 250 650 700 2090 6 f 22 339 4 f 12 ok
14 400 250 650 700 2090 6 f 22 339 4 f 12 ok
15 400 250 650 700 2090 6 f 22 339 4 f 12 ok
16 400 250 650 700 2090 6 f 22 339 4 f 12 ok
17 400 250 650 700 2090 6 f 22 339 4 f 12 ok
18 400 250 650 700 2090 6 f 22 339 4 f 12 ok
19 400 250 650 700 2090 6 f 22 339 4 f 12 ok
20 400 250 650 700 2090 6 f 22 339 4 f 12 ok
21 400 250 650 700 2090 6 f 22 339 4 f 12 ok
22 400 250 650 700 2090 6 f 22 339 4 f 12 ok
23 400 250 650 700 2090 6 f 22 339 4 f 12 ok
24 400 250 650 700 2090 6 f 22 339 4 f 12 ok
25 400 250 650 700 2090 6 f 22 339 4 f 12 ok
26 400 250 650 700 2090 6 f 22 339 4 f 12 ok
27 400 250 650 700 2090 6 f 22 339 4 f 12 ok
28 400 250 650 700 2090 6 f 22 339 4 f 12 ok
29 400 250 650 700 2090 6 f 22 339 4 f 12 ok
30 400 250 650 700 2090 6 f 22 339 4 f 12 ok
31 400 250 650 700 2090 6 f 22 339 4 f 12 ok
32 400 250 650 700 2090 6 f 22 339 4 f 12 ok
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Design of Beams with Compression Rft.

* Project :

Concrete fcu = 25 MPa

Steel fy = 400 MPa

###
Ult. Moment Breadth Depth Thick Main Comp.
Sec. Main Rft. Comp. Rft. Notes
Mu (kN.m) b (mm) d (mm) t (mm) As As
33 400 250 650 700 2090 6 f 22 339 4 f 12 ok
34 400 250 650 700 2090 6 f 22 339 4 f 12 ok
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Design of Sec. under M & N

* Project :

Concrete fcu = 25 MPa

Steel fy = 420 MPa

Ult. Moment Normal Breadth Depth Thick As Asmin Used


Sec. ecc. C1 J Rft.
Mu (kN.m) Nu (kN) b (mm) d (mm) t (mm) (mm ) (mm2)
2
As
ve+ 20 2700 500 1150 1200 Small, use I.D --- --- ### --- --- --- f ###
22
ve- 2075 -125 300 1600 1700 Big 2.98 0.741 4013 1286 4013 11 f ###
22
col 2075 -800 300 1700 1800 Big 2.83 0.723 3066 1366 3066 9 f ###22
4 0 0 0 0 0 #DIV/0! ### ### ### ### ### ### f ###0
ve+ 5270 -150 400 3600 3700 Big 4.84 0.826 4018 3857 4018 16 f ###
18
ve- 3200 -205 400 3600 3700 Big 6.03 0.842 2233 2902 2902 12 f ###
18
col 3200 -1600 400 2900 3000 Big 3.93 0.802 1190 1547 1547 7 f ###18
8 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
9 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
10 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
11 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
12 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
13 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
14 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
15 4820 -4100 800 3600 3700 Small, use I.D --- --- ### --- --- --- f ###
22
16 4820 -350 3200 3600 3700 Big 13.81 0.865 3196 4155 4155 9 f ###25
17 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
18 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
19 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
20 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
21 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
22 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
23 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
24 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
25 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
26 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
27 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
28 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
29 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
30 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
31 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
32 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Design of Sec. under M & N

* Project :

Concrete fcu = 25 MPa

Steel fy = 420 MPa

Ult. Moment Normal Breadth Depth Thick As Asmin Used


Sec. ecc. C1 J Rft.
Mu (kN.m) Nu (kN) b (mm) d (mm) t (mm) (mm ) (mm2)
2
As
33 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
34 4820 -200 250 3600 3700 Big 3.96 0.803 3712 2411 3712 19 f ###
16
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.4

* Check Shear in Beams

* Project : 7

Concrete fcu = 30 MPa

Concrete qcu cracked = 0.54 MPa

Stirrups fy = 240 MPa

Ult. Shear Breadth Depth qu As min. no. of


Sec. stirrup Stirrups /m Notes
Qu (kN) b (mm) d (mm) (N/mm ) 2
S s bran. ###
1 110 120 700 1.31 0.444 0.200 2 5 f 8 safe###
2 110 120 700 1.31 0.444 0.200 2 5 f 8 safe###
3 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
4 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
5 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
6 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
7 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
8 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
9 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
10 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
11 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
12 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
13 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
14 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
15 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
16 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
17 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
18 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
19 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
20 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
21 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
22 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
23 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
24 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
25 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
26 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
27 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
28 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
29 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
30 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
31 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.4

* Check Shear in Beams

* Project : 7

Concrete fcu = 30 MPa

Concrete qcu cracked = 0.54 MPa

Stirrups fy = 240 MPa

Ult. Shear Breadth Depth qu As min. no. of


Sec. stirrup Stirrups /m Notes
Qu (kN) b (mm) d (mm) (N/mm ) 2
S s bran. ###
32 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
33 150 250 650 0.92 0.463 0.417 2 5 f 8 safe###
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.2

* Design for Torsion

* Project :

Concrete fcu = 30 MPa

Stirrups fy = 240 MPa

Horizontal bars fy = 400 MPa ###

###
Ult. torsional moment Sec. dim. Ult. shear force ###
Sec. Mu (kN.m) b (mm) t (mm) Qu (kN)
1 16 250 800 50
qcu
qtu Notes qsu Notes qumax
0.94 N/mm 2
need rft. 0.27 N/mm 2
use min Aoh
Ao
qtcu = 0.27 N/mm2 Ph
qcu = 1.07 N/mm2
qumax = 3.13 N/mm2

Calculation of Rft.

Stirrups due to shear no. f as/s


0.0 10 /m inner
astr/s
Stirrups due to torsion no. f
6.0 8 /m outer
###
or use total stirrups no. f ###
6 8 /m Asl min
Asl
Horizontal Rft. no. f ###
4 16

6 f8 /m

6 f8 /m
0.80 m 0.80 m

1 f 10 /m

OR
0.25 m 0.25 m
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Design of Rectangular Columns

* Project :

Concrete fcu = 35 MPa Braced

Steel fy = 420 MPa Unbraced


###
Type of structure: Unbraced ###
Ult. Load Desired Dim of column As Clear Madd
Col. Reinforcement (K) l critical Notes m min (%) d (mm)
Nu (kN) m (%) b (mm) t (mm) (mm2) Height (m) (kN.m)
1.0 200 400 800 4 f 16 27.6 Unsafe 1.69 76.2 76.2
1.3 200 400 1040 6 f 16 27.6 Unsafe 1.69 76.2 76.2
C1 1000 4.60 1.20
1.6 200 350 1120 5 f 18 27.6 Unsafe 1.69 76.2 76.2
1.6 200 350 1120 4 f 20 27.6 Unsafe 1.69 76.2 76.2
1.0 200 400 800 4 f 16 18.0 Safe 1.19 32.4 32.4
1.3 200 400 1040 6 f 16 18.0 Safe 1.19 32.4 32.4
C2 1000 3.00 1.20
1.6 200 350 1120 6 f 16 18.0 Safe 1.19 32.4 32.4
1.1 200 400 880 5 f 16 18.0 Safe 1.19 32.4 32.4
1.0 200 500 1000 5 f 16 18.0 Safe 1.19 32.4 38.9
1.3 200 450 1170 6 f 16 18.0 Safe 1.19 32.4 38.9
C3 1200 3.00 1.20
1.6 200 450 1440 8 f 16 18.0 Safe 1.19 32.4 38.9
1.15 200 450 1035 6 f 16 18.0 Safe 1.19 32.4 38.9
1.0 200 600 1200 6 f 16 18.0 Safe 1.19 32.4 48.6
1.3 200 550 1430 8 f 16 18.0 Safe 1.19 32.4 48.6
C4 1500 3.00 1.20
1.6 200 550 1760 9 f 16 18.0 Safe 1.19 32.4 48.6
1.2 200 550 1320 7 f 16 18.0 Safe 1.19 32.4 48.6
1.0 200 700 1400 7 f 16 18.0 Safe 1.19 32.4 58.3
1.3 200 650 1690 9 f 16 18.0 Safe 1.19 32.4 58.3
C5 1800 3.00 1.20
Page 34 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Design of Rectangular Columns

* Project :

Concrete fcu = 35 MPa Braced

Steel fy = 420 MPa Unbraced


###
Type of structure: Unbraced ###
Ult. Load Desired Dim of column As Clear Madd
Col. Reinforcement (K) l critical Notes m min (%) d (mm)
Nu (kN) m (%) b (mm) t (mm) (mm2) Height (m) (kN.m)
C5 1800 3.00 1.20
1.6 200 650 2080 11 f 16 18.0 Safe 1.19 32.4 58.3
1.2 200 700 1680 9 f 16 18.0 Safe 1.19 32.4 58.3
1.0 200 850 1700 9 f 16 18.0 Safe 1.19 32.4 68.0
1.3 200 800 2080 11 f 16 18.0 Safe 1.19 32.4 68.0
W1 2100 3.00 1.20
1.6 200 750 2400 12 f 16 18.0 Safe 1.19 32.4 68.0
1.3 200 800 2080 11 f 16 18.0 Safe 1.19 32.4 68.0
1.0 200 950 1900 10 f 16 18.0 Safe 1.19 32.4 77.8
1.3 200 900 2340 12 f 16 18.0 Safe 1.19 32.4 77.8
W2 2400 3.00 1.20
1.6 200 850 2720 14 f 16 18.0 Safe 1.19 32.4 77.8
1.2 200 900 2160 11 f 16 18.0 Safe 1.19 32.4 77.8
1.0 200 5300 10600 28 f 22 18.0 Safe 1.19 32.4 440.6
1.3 200 4900 12740 34 f 22 18.0 Safe 1.19 32.4 440.6
W3 13600 3.00 1.20
1.6 200 4750 15200 41 f 22 18.0 Safe 1.19 32.4 440.6
1.55 200 4800 14880 40 f 22 18.0 Safe 1.19 32.4 440.6
1.0 200 5150 10300 52 f 16 18.0 Safe 1.19 32.4 430.9
1.3 200 4800 12480 63 f 16 18.0 Safe 1.19 32.4 430.9
W4 13300 3.00 1.20
1.6 200 4650 14880 75 f 16 18.0 Safe 1.19 32.4 430.9
1.35 200 4750 12825 64 f 16 18.0 Safe 1.19 32.4 430.9

Page 35 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Design of Rectangular Columns

* Project :

Concrete fcu = 35 MPa Braced

Steel fy = 420 MPa Unbraced


###
Type of structure: Unbraced ###
Ult. Load Desired Dim of column As Clear Madd
Col. Reinforcement (K) l critical Notes m min (%) d (mm)
Nu (kN) m (%) b (mm) t (mm) (mm2) Height (m) (kN.m)
1.0 200 1200 2400 12 f 16 18.0 Safe 1.19 32.4 97.2
1.3 200 1100 2860 15 f 16 18.0 Safe 1.19 32.4 97.2
W5 3000 3.00 1.20
1.6 200 1050 3360 17 f 16 18.0 Safe 1.19 32.4 97.2
1.55 200 1050 3255 17 f 16 18.0 Safe 1.19 32.4 97.2

Page 36 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.2

* Design of Circular Columns

* Project :

Concrete fcu = 30 MPa Braced

Steel fy = 400 MPa Unbraced


###
Type of structure: Unbraced ###
Ult. Load Desired Diamter As Clear Madd
Col. Reinforcement (K) l critical Notes m min (%) d (mm)
Nu (kN) m (%) D (mm) (mm2) Height (m) (kN.m)
1.0 450 1590 8 f 16 13.3 Safe 0.94 40.0 68.0
1.3 450 2067 11 f 16 13.3 Safe 0.94 40.0 68.0
1 1700 5.00 1.20
1.6 400 2010 11 f 16 15.0 Safe 1.03 45.0 76.5
1.6 400 2010 11 f 16 15.0 Safe 1.03 45.0 76.5
1.0 750 4416 22 f 16 11.0 Safe 0.82 45.7 224.0
1.3 700 5000 25 f 16 11.8 Safe 0.87 49.0 240.0
2 4900 6.90 1.20
1.6 700 6154 25 f 18 11.8 Safe 0.87 49.0 240.0
1.6 700 6154 25 f 18 11.8 Safe 0.87 49.0 240.0
1.0 650 3317 17 f 16 12.7 Safe 0.91 52.7 213.6
1.3 650 4312 22 f 16 12.7 Safe 0.91 52.7 213.6
3 4050 6.90 1.20
1.6 650 5307 27 f 16 12.7 Safe 0.91 52.7 213.6
1.3 650 4312 22 f 16 12.7 Safe 0.91 52.7 213.6
1.0 650 3317 17 f 16 7.4 Safe 0.63 17.7 69.1
1.3 650 4312 22 f 16 7.4 Safe 0.63 17.7 69.1
4 3900 4.00 1.20
1.6 650 5307 27 f 16 7.4 Safe 0.63 17.7 69.1
1.5 650 4975 25 f 16 7.4 Safe 0.63 17.7 69.1
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 12.3

* Design of Isolated Footing

* Project :

Concrete fcu = 25 MPa

Steel fy = 400 MPa

Bearing capacity qall = 150 KPa

Column working load Column dim. Extension


foot Nw (kN) b (mm) t (mm) of P.C (mm)
F1 1000 300 500 300 Working P.C

Dims. of P.C : B (mm) L (mm) t (mm)


2,550 2,750 300

Dims. of R.C : B (mm) L (mm) t (mm)


1,950 2,150 600

Actual soil stress (kPa) Notes


146 safe

Stress above P.C (kPa)


254

Shear stress (N/mm2) qcu (N/mm2) Notes


0.37 < 0.65 safe

Punching stress (N/mm2) qcup (N/mm2) Notes


0.61 < 1.29 safe

Calculation of Rft. : Asmin


795 mm2

Long Direction : Mu /m As /m no. f total no.


122 695 8 12 /m 16

Short Direction : Mu /m As /m no. f total no.


122 695 8 12 /m 18
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 12.3

* Design of Isolated Footing under Moment

* Project :

Concrete fcu = 25 MPa

Steel fy = 400 MPa

Bearing capacity qall = 500 KPa Secondary case

Column working load Moment Column dim. Extension


foot Nw (kN) Mw (kN.m) b (mm) t (mm) of P.C (mm)
F1 650 200 500 830 0 Working P.C

Dims. of P.C : B (mm) L (mm) Lno tens (mm) t (mm)


1,520 1,850 1,753
Choose dim of P.C 1,500 1,850 0

Dims. of R.C : B (mm) L (mm) t (mm)


1,500 1,850 500

Max. Stress (kPa) = 480 Safe Secondary case


Min. Stress (kPa) = 13 No tension
Max. Stress (kPa) = 480 Safe Secondary case
After Redistribution
Min. Stress (kPa) = 13

Shear stress (N/mm2) qcu (N/mm2) Notes


0.45 < 0.65 safe

Punching stress (N/mm2) qcup (N/mm2) Notes


0.28 < 1.29 safe

Calculation of Rft. : Asmin


645 mm2

Long Direction : Mu /m As /m no. f total no.


81 571 6 12 /m 10

Short Direction : Mu /m As /m no. f total no.


46 326 6 12 /m 12

Page 39 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 12.3

* Design of Isolated Footing under Moment

Results:
Nw = 650 kN

Mw = 200 kN.m

0.50 m

0.00 m

12.99
kPa

480
kPa

1.85 m

0.50
/m
1.50 m

1.50 m
0.50

12

0.83
6 f

6 f 12 /m

1.85 m

F1

Page 40 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 12.3

* Design of Isolated Footing under Double Moment

* Project :

Concrete fcu = 25 MPa ###

Steel fy = 400 MPa ###

Bearing capacity qall = 150 KPa Secondary case ###

###
###
Column working load Moment Moment Column dim. Extension
foot Nw (kN) Mwx (kN.m) Mwy (kN.m) b (mm) t (mm) of P.C (mm)
F1 400 150 300 300 500 300 ###

###
Dims. of P.C : B (mm) L (mm) t (mm) ###
1,700 3,400
Choose dim of P.C 3,000 3,200 300

Dims. of R.C : B (mm) L (mm) t (mm)


2,400 2,600 500

LRC
3 1

Mwx

BRC bcol Mwx Mwy BPC

tcol

4 2
LPC

Eccentricities:
ex = 0.28 m ey = 0.55 m
P1 Stress (kPa) = 146 Safe Secondary case
P2 Stress (kPa) = 84
P3 Stress (kPa) = 29

Page 41 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 12.3

P4 Stress (kPa) = -33 Tension on soil

Using chart:
ex/B = 0.09 ey/L = 0.17 K= 2.67

Max. Stress (kPa) = 150 Safe Secondary case

Using Approximate method:


Beff (mm) = 2446 Leff (cm) = 2092
###
Average Stress (kPa) = 106 Safe primary case ###
###
Shear stress (N/mm2) qcu (N/mm2) Notes
0.36 < 0.65 safe

Punching stress (N/mm2) qcup (N/mm2) Notes ###


0.42 < 1.29 safe
###
Calculation of Rft. : Asmin ###
645 mm2 ###
###
Long Direction : Mu /m As /m no. f total no. ###
82 577 6 12 /m 15 ###
###
Short Direction : Mu /m As /m no. f total no.
126 884 8 12 /m 21

Results:

2.60 m 150 kPa


29 kPa 146 kPa

0.50

0.50
F1
/m
2.40 m

3.00 m
0.30

12
8 f

6 f 12 /m

-33 kPa 84 kPa

Page 42 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 12.3

(0.00 kPa) 3.20 m

Page 43 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 12.2

* Design of Fence Footing

* Project :

Concrete fcu = 25 MPa

Steel fy = 400 MPa

Bearing capacity qall = 100 KPa

Column working load Moment Column dim. Ecc. Extension


foot Nw (kN) Mw (kN.m) b (mm) t (mm) e (mm) of P.C (mm)
F1 63 5 250 250 525 200

Dims. of P.C : B (mm) L (mm) Lno tens (mm) t (mm)


1,150 1,150 2013
Choose dim of P.C 1,500 1,300 200

Dims. of R.C : B (mm) L (mm) t (mm)


1,100 1,100 400

Max. Stress (kPa) = 109 Safe secondary case


Min. Stress (kPa) = -24 Tension on soil on 0.18 L
Max. Stress (kPa) = 110 Safe secondary case
After Redistribution
Min. Stress (kPa) = 0

Shear stress (N/mm2) qcu (N/mm2) Notes


0.17 < 0.65 safe

Punching stress (N/mm2) qcup (N/mm2) Notes


0.36 < 1.29 safe

Calculation of Rft. : Asmin


525 mm2

Long Direction : Mu /m As /m no. f total no.


48 424 5 12 /m 6

Short Direction : Mu /m As /m no. f total no.


9 83 5 12 /m 6

Page 44 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 12.2

* Design of Fence Footing

Results:
Nw = 63 kN

Mw = 5 kN.m

0.40 m

0.20 m

0
kPa

110
kPa

1.10 m

0.40
/m
1.10 m

1.50 m
0.25

12

0.25
5 f

5 f 12 /m

1.30 m

F1

Page 45 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 12.1

* Design of Combined Footing

* Project :

Concrete fcu = 30 MPa

Steel fy = 400 MPa

Bearing capacity qall = 200 KPa

F9
Column working load Column dim. (mm) Extension
Col Nw (kN) trans. long. of P.C (mm)
Smaller 1350 300 600 100
Larger 1800 300 800 100

Distance from c.g to c.g: 1.9 m

Resultant of 2 loads is at: 1.09 m from smaller column

Dims. of P.C : B (mm) L (mm) Soil stress (kPa)


minimum 5,800 3,000
chosen 5,800 3,200 188 safe

Dims. of R.C : B (mm) L (mm) t (mm)


5,600 3,000 700

LRC

Distance c.g to
c.g
BRC Dtransverse Dtransverse BPC

Dlong Dlong

LPC

Punching stress (N/mm2) qpu (N/mm2) qcup (N/mm2) Notes


Samller column 1.84 > 1.41 unsafe

Page 46 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 12.1

* Design of Combined Footing


Larger column 1.04 < 1.24 safe

Longitudinal direction:

Shear stress (N/mm2) qu (N/mm2) qcu (N/mm2) Notes


max. shear stress 0.14 < 0.72 safe

Top Rft. : Mu /m As /m no. f total no.


83 945 9 12 /m 51

Bottom Rft. : Mu /m As /m no. f total no.


11 945 5 16 /m 29

Transverse direction:

Shear stress (N/mm2) qu (N/mm2) qcu (N/mm2) Notes


max. shear stress 1.05 > 0.72 unsafe

Top Rft. : no. f total no.


5 12 /m 16

Bottom Rft. : Mu /m As /m no. f total no.


992 5050 26 16 /m 79

Results:

3.00 m

9 f 12 /m

0.70
/m

/m
5.60 m

5.80 m
12

16

1.09 m
f

26
5

5 f 16 /m

Page 47 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 12.1

* Design of Combined Footing

3.20 m

Page 48 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 12.1

* Design of Strap Beam Footing

* Project :

Concrete fcu = 25 MPa ###

Steel fy = 400 MPa ###

Bearing capacity qall = 150 KPa ###

Column working load Column dim. (mm) Extension Thickness


Col Nw (kN) trans. long. of P.C (mm) of P.C (mm)
Exter. 685 300 500 0 300
Inter. 1270 300 900 300 300
Rex
Distance from c.g to c.g: 4.9 m ###

Take eccentricity = 0.85 m ###

Dims. of P.C : B (mm) L (mm) Soil Stress (KPa)


External footing 2,700 2,200 143
Internal footing 2,550 3,150 144
###
Dims. of R.C : B (mm) L (mm) t (mm)
External footing 2,100 1,900 500
Internal footing 1,950 2,550 500

Page 49 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 12.1

* Design of Strap Beam Footing

Longitudinal direction: shr1


shr2
Dim. of strap beam : b (mm) t (mm) shr3
500 1000 shstres1
as/s
Rft. of strap beam : Mu (kN.m) no. f as/s min
Top Rft. 616 6 22 ###
Bottom Rft. 238 4 18 ###
shr1 out
Shear stress (N/mm2) qu (N/mm2) qcu (N/mm2) Notes
max. shear stress inside footing 0.70 > 0.65 cracked

Shear stress (N/mm2) qu (N/mm2) qmax (N/mm2) Notes


max. shear stress on beam 1.68 < 2.86 safe
c1
Stirrups /m : no. f ex
6 10 4 branches in

Transverse direction:
###
Bottom Rft. : Mu /m As /m no. f total no.
External footing 106 744 7 12 /m 15
Internal footing 94 663 6 12 /m 17

Page 50 of 69
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 12.1

* Design of Pile Cap

* Project :

Concrete fcu = 30 MPa

Steel fy = 400 MPa

Pile Diameter = 0.50 m

Pile Capacity = 500 kN

Column working column dim. extension


cap load Nw (kN) b (mm) t (mm) of P.C (mm)
PC1 1500 300 700 100

Estimated no. of piles = 4 piles

Pile spacing is taken from 1.25 to 3.0 m = 1.50 m in long direction

Pile spacing is taken from 1.25 to 3.0 m = 1.50 m in short direction

Short dir. Long dir.


Choosen arrangement of piles = 2 x 2 Piles used = 4

Dims. of P.C cap: B (mm) L (mm) t (mm)


3,200 3,200 200

Dims. of R.C cap: B (mm) L (mm) t (mm)


3,000 3,000 900

Actual pile load (kN) Notes


437 safe

Shear stress (N/mm2) qcu (N/mm2) Notes


0.53 < 0.72 safe

Punching stress (N/mm2) qcup (N/mm2) Notes


0.51 < 1.31 safe

Calculation of Rft. : Asmin


1245 mm2

Long Direction : Mu /m As /m no. f total


175 1245 7 16 /m 22

Short Direction : Mu /m As /m no. f total


262 1245 7 16 /m 22
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 12.1

* Design of Pile Cap under Moment

* Project :

Concrete fcu = 30 MPa ###

Steel fy = 400 MPa ###

Pile Diameter = 0.50 m ###

Pile Capacity = 600 kN

Column working column dim. Working moment extension


cap load Nw (kN) b (mm) t (mm) Mw (kN.m) of P.C (mm)
PC1 2000 800 800 1800 100

Spacing of piles in direction of moment = 1.50 m no. of Piles 4

Spacing of piles in transverse direction = 1.50 m no. of Piles 3


Total no. of piles = 12 ###
###
Dims. of P.C cap: B (mm) L (mm) t (mm) ###
4,700 6,200 100 ###
###
Dims. of R.C cap: B (mm) L (mm) t (mm) ###
4,500 6,000 1200 ###

Max. Load (kN) Min. Load (kN)


1st piles row to center, y1 0.75 m 320 160 ###
2nd piles row to center, y2 2.25 m 480 0 ###
3rd piles row to center, y3 0 m 240 240 ###
4th piles row to center, y4 0 m 240 240 ###
All Safe Tension Appears ###

Shear stress (N/mm2) qcu (N/mm2) Notes


0.71 < 0.72 safe
###
Punching stress (N/mm ) 2
qcup (N/mm ) 2
Notes
0.34 < 1.41 safe ###

Calculation of Rft. : Asmin


1695 mm2 ###
###
Long Direction : Mu /m As /m no. f total ###
999 2676 8 22 /m 37
###
Short Direction : Mu /m As /m no. f total
295 1695 9 16 /m 55
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Design of Retaining Wall

* Project :

Concrete fcu = 25 MPa

Steel fy = 420 MPa 0.25


0.0 kN/m`
Bearing capacity qall = 400 kPa

g = 18.0 kN/m3

1.30

0.30
C = 0.0 N/mm2

f = 35 o
1.30 0.450 0.000

0.40 R.C
0.30 P.C

0.30 0.70 0.00

1.00
C= 0.0 N/mm2 f = 30 o

Factor of safety against sliding = -0.86 Not satisfactory

Factor of safety against overturning = 116.67 Satisfactory

Max. stress on soil = 58.7 kPa Safe stress


Min. stress on soil = 24.2 kPa No tension on soil
Max. stress on soil = 58.7 kPa Safe stress
After Redistribution
Min. stress on soil = 24.2 kPa

Calculation of Rft. :

Mu (kN.m) C1 J As (mm2) As min


For wall 0.0 191.70 0.826 0 330 3 f 12 /m
For Base 4.5 26.16 0.826 37 525 5 f 12 /m
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.3

* Design of Water Section

* Project :

Concrete fcu = 25 MPa

Concrete fctr = 3.0 MPa

Steel fy = 420 MPa

Working Moment Normal Force


Sec. Mw (kN.m) Nw (kN)
1 7 87 Tension

Dims of sec: b (mm) t (mm) fct (N/mm2)


1000 250 1.0

Properties of sec: tv (mm) fct all (N/mm2)


379 2.3 Safe

Design of sec: d (mm) C1 J Ascalc Asmin As (mm2)


200 37.46 0.826 368 422 422

use: 4 f 12 bcr = 0.83


Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 2.1

* Design of Simple Deep Beams

* Project :

Concrete fcu = 25 MPa

Steel fy = 400 MPa

Width (b) = 0.30 m


Span (L) = 4.00 m
Height (H) = 3.40 m
L/H = 1.18 Deep Beam
Empirical analysis accepted

yct = 2.87 m
Ww = 200.0 kN/m
Mw = 400.0 kN.m
Qw = 280.0 kN

As calc = 601 mm2


As min = 1485 mm2
As used = 1485 mm2
8 f 16 Bottom RFT.

Top loaded deep beam

Stirrups = Use min. web RFT


5 f 10 /m 2 Legs Vertical
Safe
5 f 10 /m 2 Legs Horizontal

5 f 10 /m
3.40

5 f 10 /m

8 f 16

4.00
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 2.1

* Design of Continuous Deep Beams

* Project :

Concrete fcu = 25 MPa

Steel fy = 400 MPa

Width (b) = 0.30 m


Span (L) = 4.00 m
Height (H) = 3.40 m
L/H = 1.18 Deep Beam
Empirical analysis accepted

yct +ve = 1.72 m


yct -ve = 1.48 m
Ww = 80.0 kN/m
Mw +ve = 450.0 kN.m
Mw -ve = 400.0 kN.m
Qw = 250.0 kN

As calc = 1128 mm2 As calc = 1166 mm2


As min = 1485 mm2 As min = 1515 mm2
As used = 1485 mm2 As used = 1515 mm2
5 f 20 5 f 20
Bottom RFT. Top RFT.

Top loaded deep beam

Stirrups = Use min. web RFT


5 f 10 /m 2 Legs Vertical
Safe
5 f 10 /m 2 Legs Horizontal

5 f 20
3.40

5 f 20

4.00 4.00
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 1.1

* Design of Corbel

* Project :

Concrete fcu = 25 MPa

Steel fy = 400 MPa

Stirrups fy = 240 MPa

Concrete Dims:
Thickness at column = 700 mm
Cover = 50 mm
d= 650 mm
Breadth = 300 mm
Cantilever length L = 800 mm
Lateral load height D = 100 mm
Distance of VL load a = 600 mm
Connection between corbel and column:
Monolitic cast concrete
m= 1.2

Loads:
Qu = 200 kN
Nu = 40 kN

As = 702 mm2
Asmin = 366 mm2
Used As = 702 mm2 4 f 16 Main RFT

Ah = 293 mm2 3 f 8 Horizontal stirrups


2 Branches Spacing = 144 mm
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.4

* Deflection of Cantilever

* Project :

Concrete fcu = 30 MPa

PDL+ PLL
WDL+ WLL

Span ###
###
Breadth Depth Thickness Span Ig
Sec. Properties of sec: b (mm) d (mm) t (mm) L (m) ###
1 1000 220 250 2.5
z2
z
Top Rft.: no. f area ###
5 16 1005 mm2 z
Inv
Bottom Rft.: no. f area
5 16 1005 mm2 Ie tot
Ie d

Working loads: PDL (kN) PLL (kN) WDL (kN/m) WLL (kN/m)
self weights 2.50 0.0 self weights 6.25 3.0 m=
finish+walls 0.00 finish+walls 3.25 a=
a2=
Ec = 24,100 MPa

Ieff = 8.29E+08 mm4 due to all loads


Di
Initial deflection = 3.7 mm ###

Long term deflection = 8.5 mm after 5 years Unsafe, camber may be used
Allowable value = 5.6 mm L / 450

Live load deflection = 1.6 mm Safe


Allowable value = 6.9 mm L / 360

Incremental deflection = 3.3 mm Safe Flexible clad


Allowable value = 5.2 mm L / 480 Brittle cladding Brittle cladd
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.4

* Deflection of Simple R-section

* Project :

Concrete fcu = 30 MPa

PDL+ PLL
WDL+ WLL

Span/2 Span/2
###
###
Breadth Depth Thickness Span Ig
Sec. Properties of sec: b (mm) d (mm) t (mm) L (m) ###
1 300 650 700 8
z2
z
Top Rft.: no. f area ###
4 16 804 mm2 z
Inv
Bottom Rft.: no. f area
6 22 2280 mm2 Ie tot
Ie d

Working loads: PDL (kN) PLL (kN) WDL (kN/m) WLL (kN/m)
self weights 40.0 50.0 self weights 15.0 10.0 m=
finish+walls 30.0 finish+walls 10.0 a=
a2=
Ec = 24,100 MPa

Ieff = 7.453E+09 mm4 due to all loads


Di
Initial deflection = 17.5 mm ###

Long term deflection = 37.0 mm after 5 years Unsafe, camber may be used
Allowable value = 32.0 mm L / 250

Live load deflection = 6.0 mm Safe


Allowable value = 22.2 mm L / 360

Incremental deflection = 15.4 mm Safe Flexible cla


Allowable value = 16.7 mm L / 480 Brittle cladding Brittle clad
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.4

* Deflection of Simple T-section

* Project :

Concrete fcu = 30 MPa B

C As top ts

PDL+ PLL
WDL+ WLL b
h

Span/2 Span/2
C As bottom

###
Breadth Depth Thickness Span
Sec. Properties of sec: B (mm) b (mm) ts (cm) h (mm) t (mm) L (m)
1 800 300 120 580 700 8
###
###
Top Rft.: Cov. (mm) no. f area ###
50 4 16 804 mm2
###
Bottom Rft.: Cov. (mm) no. f area ###
50 6 22 2280 mm2 m=
a=
a2=
Working loads: PDL (kN) PLL (kN) WDL (kN/m) WLL (kN/m) ###
self weights 40.0 50.0 self weights 15.0 10.0 Ie tot
finish+walls 30.0 finish+walls 10.0 Ie d

Ec = 24,100 MPa

Ieff = 9246237825 mm4 due to all loads


Di
Initial deflection = 14.1 mm ###

Long term deflection = 29.8 mm after 5 years Safe


Allowable value = 32.0 mm L / 250

Live load deflection = 4.8 mm Safe


Allowable value = 22.2 mm L / 360
Incremental deflection = 12.4 mm Safe Flexible clad
Allowable value = 16.7 mm L / 480 Brittle cladding Brittle claddi
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.7

* Calculation of Crack Width

* Project :

Concrete fcu = 30 MPa

Steel fy = 400 MPa

Comp. side
Thickness

Z
N.A

Tens. side
Breadth

INPUT DATA:
Breadth (B) = 1000 mm
Thickness (t) = 300 mm
Tension RFT. = 10 T 16 = 2011 mm2
Tension RFT. Cover = 50 mm, "to c.g of RFT bars"
Compression RFT. = 10 T 16 = 2011 mm2
Comp. RFT. Cover = 50 mm, "to c.g of RFT bars"
Bars type: Ribbed bars K1 = 0.8
b1 = 0.8
Duration of load: Permanent loads b2 = 0.5
Straining action: Bending moment K2 = 0.5
Mservice = 90 kN.m
Nservice = 30 kN Tension
Exposure category: Second, unprotected tension surfaces
Max. crack width (wkmax) = 0.20 mm

OUTPUT DATA:
Modular ratio (n) = 8.3
Neutral Axis depth (Z) = 70 mm
Tens. Steel stress (fs) = 207 MPa
Cracking stress (fsr) = 110 MPa
Srm = 110.9 mm
esm = 918.5 me
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 11.7

* Calculation of Crack Width

Crack width (wk) = 0.17 mm Acceptable