Biospec Brochure
Biospec Brochure
MRI/ MRS
Innovation with Integrity
Unlimited Research Possibilities
Angiography
- flow contrast and flow analysis of the velocity of
each voxel for glioblastoma and aneurysm studies
Cardiology - investigation of cardiac strain, ejection fraction, and
septum defects, using triggered sequences or Bruker’s patented
IntraGate for navigator based retrospective gating
Diffusion - visualization of disturbed pathology, such as in multiple
sclerosis, epilepsy, and stroke tumors
fMRI - insight into the brain‘s function
Molecular MRI - imaging at the cellular level
Perfusion - with and without CA for tumor- detection, -neoangio-
Cortical Layers of Mouse
genesis, and -vascularization, and disruption of the blood brain
Cerebellum in vivo
barrier MRI CyroProbeTM at 7 Tesla, Magnitude and phase
Spectroscopy – quantification of metabolic disorders and long images depict cortical layers of mouse cerebellum –
term changes in metabolic processes ml (molecular layer), gl (granular layer),
WM (white matter), PI (Purkinje cells)
Acquisition details: SWI FLASH, resolution
(30 × 30 × 200) µm³, scan time: 12 min 50 s.
Courtesy: N. Baxan, D. von Elverfeldt, University
Medical Center Freiburg, Freiburg, Germany
DTI Fibers
Brain connectivity studies in small animals are
challenging but can be achieved using state-of-
the-art MRI technologies for acquisition, such as
the 7 T BioSpec® with MRI CryoProbe. High-
resolution DTI MRI and fiber tracking of the living
Angiography
mouse brain delineate the organization of the
Time-Of-Flight angiography with no contrast agent fiber tracts.
at high spatial resolution, showing the excellent Acquisition details: MRI CyroProbeTM at 7 Tesla,
contrast that enables the identification of fine vas- DTI-EPI, diffusion directions: 30, resolution:
cular structures. (12.5 × 15.5 × 50) µm³, scan time: 25 min.
Acquisition details: Mouse brain in vivo: MRI Courtesy: L. A. Harsan, D. von Elverfeldt et al.,
CryoProbe™ at 9.4 Tesla, GEFC, TR: 30 ms, University Medical Center Freiburg,
TE: 5.9 ms, resolution: (59 × 59 × 59) µm3 Freiburg, Germany
Courtesy: H. Waiczies, Berlin Ultra-High Field
Facility (BUFF), MDC, Berlin, Germany
The Benefits You Want
Leading scientists worldwide are taking their
research closer to the molecular and cellular level
thanks to BioSpec®. Designed for the emerging
market of preclinical imaging and molecular MRI,
its innovative modular concept enables virtually any
small animal MR imaging application in life science,
biomedical, and preclinical research.
BioSpec® already brings proven performance,
safety, convenience, and future-proof cost-effective
operation to over 600 labs worldwide. With our new
multimodal animal platforms and accessories and
our latest generation ParaVision® software more
Cellular Imaging users than ever can access a new level of research
– Mesenchymal stem cells were labeled and quicker than they think.
used as markers for stroke regions. They
are readily visible in T2- and T2*-weighted Key Benefits
images both in vivo and ex vivo. Full 3D Cost
effective - Helium zero boil off and Nitrogen-free for
brain coverage enables quantification and reduced maintenance costs and longer service intervals
volume rendering. Scalable – upgradeable electronics, options, and accessories
Courtesy: P. Walczak, J. W. Bulte, et al. to keep your system at the cutting edge
Johns Hopkins University School of Compatible – multimodal animal handling solutions for use
Medicine, Baltimore, Maryland, USA with all Bruker preclinical modalities
Intuitive – with Bruker’s gold standard preclinical imaging
software, ParaVision®, users can start scanning immediately
Proven – more than 30 methods with various contrast
modules and hundreds of measurement protocols designed
and tested on mice and rats to guarantee the highest image
quality
Key Technologies
Field
strengths – 4.7 to 15.2 Tesla ultra-shielded supercon-
ducting magnets with reduced stray field
Bore sizes – 11 to 40 cm for optimal working space
Gradient diameters – 6, 9, 12, 20, 26 cm, with 6 and 12 cm
gradients available as inserts (dual gradients)
Gradient strength – up to 1000 mT/m for highest duty cycles
Shim sets – Full 3rd order (6 cm) and 2nd order (9-26 cm) for
best homogeneity
Gradients, Coils, and Electronics
The World’s Leading Hardware
Gradients
The high performance BGA-S HP gradient series delivers
unsurpassed slew rates, up to 9000 T/m/s, and gradient
strengths up to 1000 mT/m. Integrated shim coils enable
optimal field homogeneity even at the highest magnetic
fields. The dedicated cooling design results in unique
duty cycle specifications for high end fMRI applications.
Gradients can be used as inserts and thanks to automat-
ic hardware recognition they are easily exchangeable.
RF-coils
RF-coils are the interface to the sample and have a major
impact on quality, acquisition time, and workflow. Bruker
delivers application-optimized RF-coils for head, brain,
cardio, abdomen, spine, and arterial spin labeling, as
well as RF-coils for non-proton applications for mice and
rats. The closed-loop helium-cooled MRI CryoProbeTM
series RF-coils are available for mice and rats and offer
uncompromised performance for highest signal-to-noise Localized Spectroscopy
requirements. STEAM spectrum of the mouse brain acquired
using the MRI CryoProbeTM at 15.2 Tesla.
AVANCE™ Electronics Acquisition details: STEAM, voxel size:
The AVANCE system architecture delivers an (2 x 2 x 2) mm³, TR: 8 s, 128 averages, resolu-
unprecedented level of digital control for high quality and tion enhancement with shifted Gauss filtering,
high speed MR imaging and spectroscopy applications, TE: 1.1 ms, shift: 7%, broadening: 7 Hz
while offering great flexibility and highly scalable
transmitter and receiver channel architecture.
MRI scanner operation has never been easier, with sin-
gle push-button scanner operation and complete hard-
ware detection for RF-coils, gradients, shims, and signal
routing.
1
H four channel phased array re- The latest innovation for leading image quality in rat brain Available as a commercial pro-
ceive-only MRI CryoProbe for rat imaging with an enormous signal-to-noise gain of up to duct for 9.4 T
brain applications 2.4 in vivo.
1
H four channel phased array recei- Thanks to the remarkable signal-to-noise gain, a dramatic The four channel phased array
ve-only MRI CryoProbe for mouse scan time reduction is possible while keeping the coils are available at 7 T, 9.4 T,
applications resolution very high. In comparison with a room tempera- and 11.7 T.
ture coil, a four channel phased array coil typically provides
a signal-to-noise-gain of 2.5 in vivo.
1
H Quadrature transmit/receive The quadrature transmit/receive MRI CryoProbe provides Available as a commercial pro-
MRI CryoProbe for mouse an immense signal-to-noise gain of 2.5 to 3.0 in vivo. This duct for 4.7 T, 7 T, 9.4 T, 11.7 T, and
applications MRI CryoProbe is also available in a smaller diameter 15.2 T and for 9.4 T and 11.7 T for
version for 6 cm gradients. use with the 6 cm gradient
X-nuclei MRI CryoProbe with com- Gains in signal-to-noise benefit from lower NMR Available for 13C as a commercial
bined 1H room temperature RF-coil frequencies: The lower the frequencies of the nu- product at 7 T and 9.4 T, other
for mouse applications clei, the higher the SNR gain. Therefore signal- frequencies and nuclei upon
to-noise gains of a factor of 5 are possible in 13C request.
measurements.
ParaVision®
Software for Performance, Flexibility, and Routine Optimization
High Performance
With true 64-bit architecture and parallel multi-core ac-
quisition and reconstruction, ParaVision delivers high-
resolution 3D images up to virtually unlimited size. It
includes an extensive set of routine and advanced im-
aging sequences, offers seamless integration of paral-
lel transmission techniques and navigator handling, and
incorporates a unique, integrated field map-based shim-
ming procedure.
Bruker BioSpin
www.bruker.com/mri
[email protected]