The instructions of the JGD 8-route SCU

(Synchronous Controller Unit)


Contents

I. the instructions of the type

II. the main functions of structures

III. the instructions of the top

IV. the diagram of the top

V. the operations of the panel

VI. the parameters

VII. the detail instructions of the parameters

VIII. the multistation connection and the notice

IX. the adding advice of the JGD 280A parameters

X. the failure overhaul and the maintenance

XI. the figure measurement

1
The JGD SCU is a series of synchronous controller equipment in the basic
of the single-type SCU. The inside is full digital designed with the computer as
the center. Each controller can control the operation of 4 or 8 machines at the
same time, which is very flexible and easy. JGD series have good functions,
and the technology is in the advanced level in China. And in the capability the
JGD series can compare beauty with the products of the same kind abroad. It
can be widely used in all kinds of machine equipments combined by several
timing systems in the industries such as the electric power, the steel, the paper
making, the cottoncracy, the printing and dyeing, the cable and optical fiber and
the plastics. It can control the furl speed, the displacement, the strain and the
distance, which is the best choice in the machine equipments.

I. The instructions of the type

JGD 280 (A)

Edition number
Controller output routes
Controller series number

1. The main characters


A. digitization
The JGD series controller is controlled by one-chip computer which
can set many parameters of the controller. And the parameters can be
displayed in number. The controller has memory bank inside and it
will automatically remain the parameters the user sets after power off.
B. powerful functions
1) The JGD series controller each has three set output styles (inside
set, out voltage set and out electrical current set).
2) The JGD-240 controller each can control 4 single units which have
four routes output (V01-V04). And the JGD-280 controller each
can control 8 single units which have eight routes output
(V01-V08).
3) The output of one controlling unit can be the input of other
controlling units (the units can be used in series or in parallel
connection). One controller can be used as 2 or 3 controllers.
4) It has the functions of start up and stop gradually, and the time can
be reset (0~100s).
5) It has the failure-alerting and start-up signal relay output, and the
driving power can reach to 5A.
C. high precision

2
The output and input simulation signal of the series controller
adopts the A/D and D/A transducers with high resolution ratio, and the
resolution ratio can reach to 0.1%.
D. versatility
The out set input adopts the normal 0~10V or 4~20mA, the
controlling output is 0~10V, and it can be matched to kinds of machine
timing controller.
It has the peculiar feedback signal and offset △f controlling style.
Through the external resistance it can make kinds of transducers of
voltage output and current output compatible.
E. convenient use
1) The user can modify the controlling parameters when the controller
is in the operating state, which is very convenient for the user to
debug the facilities.
2) It has the function of locking the set parameters, which will prevent
the other to modify privately.
3) It has fewer wires outside, which is convenient for the user’s
designing and debugging the facilities. It will save lots of
manpower, material resources and financial resources.
F. safe working
The JGD series SCU is designed and made at pains. The working
power inside is switching power which has better interference killing
feature, and the range of working voltage is wide. We can assure that it
can work normally in the place where the waving range of the electric net
voltage is wide. Its working voltage is 150~300VAC.
2. the main qualifications
A. the controlling voltage output
• Output voltage resolution ratio 0.01V
• Output voltage drive power ≤ 5mA
• Output voltage stability ≤ 0.2%
B. the set and feedback signal input
• the set and feedback signal input resolution ratio 0.01V
• the out set voltage input precision ≤ 0.4%
• the feedback voltage input precision ≤ 5± 0.01V
C. the inside power output load capacity
• +24V power max output current ≤ 500mA
• +10V power max output current ≤ 10mA
• ±5V power max output current ≤ 100mA
3. service conditions
working voltage (alternating current): 220V ± 30% 50~60Hz
working environment humidity: 0~50°C
relative environment humidity: < 90% no dew

3
altitude height: < 1000m
There is no etchant gas, mill dust or highly flammable and explosive
dangerous goods around.

II. the main functions of structures


It has practical functions and better interference killing feature, and it is
stable and credible. The following are its features:
∗ The facility is made up of 8 units, one route is inside main set, the
second route is outside main set, and the eighth route is feedback set. The
feedback uses ±5V inside power.
∗ The inside main set GD can be adjusted by the keys UP and DOWN.
∗ The facility provides one absolute +24V/0.5A direct current.
The system is made up by the following parts:
1. the power
Switch the 220V alternating current to the following direct current
power:
±5V/200mA: +10V/10mA; +24V/0.5A. And the +24V is an
isolating power.
2. the main set part
The controller has three isolating main set fountain inside, and the user
can choose freely as he likes.
The inside main set GD: The range of the inside main set GD is
0.00~10.00, and the resolution ratio is 0.01. The value of the function
code F34 on the synchronous controller unit is assigned to GD, that is to
say the initial value of GD when start up is F34. After using the UP
and DOWN tops, G0 changes, and the changed value of GD will be
missing when the synchronous adjuster is power off. When the
machine starts up next it will still use the initial value F34. As the
parameter F34 will not change as the running of the UP and DOWN tops.
F34 must be reset through the parameter-set style, and its value can be
remaining when power off. As soon as the F34 is reset through the
parameter-set successfully it will assign the value to GD.
The outside main set 1 G1: The out set is input through the 9# and
8# tops. There are two ways to input the set: 0~10VDC and 4~20mA.
The two ways can be chosen by the function code F33.
The outside main set 2 G2: The outside main set 2 is input
through the 10# and 11# tops with the signal 0~10VDC.
3. the upper and lower bound transaction of the main set (cloth-worn
function)
Gi’= Glower limit when Gi < Glower limit
Gi’= Gi when Glower limit < Gi < G upper limit
Gi’= G upper limit when Gi>G upper limit

4
After the upper and lower bound transaction of the main set, Gi’will
be bounded by the set lower limit and set upper limit.
4. the ascending and descending time transaction of the speed
After the ascending and descending time transaction of the speed, the
change slope of Gi’will be limited by the ascending slope(10.00/TUP) and
the descending slope(10.00/TDOWN).
5. the units parts
There are 8 isolating units in the controller, and the following are the
functions:
Vi = Si * KSi + Fi * KFi
In the formula:
1) Vi is the output of the i unit, and the range is : 0~10V.
2) Si is the unit set of the i unit, and the input source is chosen by the
function code.
3) KSi is the set proportion of the i unit, and it is set by the function code
(the range: 0.00~15.00).

III. the instructions of the top


1#: GS +24V GND (the GND is independent which is isolated with the
+10V GND and the ±5V GND)
2#: R/S the start-up controller
3#: +24V +24V isolating power
4#: ERR the link input top of the outside failure
5#: GS the same as 1#
6#: UP the ascending top(it will work when the inside is set)
7#: +10V the outside main set power
8#: GND the outside main set 1 GND
9#: G1 the outside main set 1 input top (there are two set styles the
voltage and the electric current)
10#: G2 the outside main set 2 input top (there is only one set
stylethe voltage)
11#: GND the outside main set 2 GND
12#: +10V the outside main set power
13#: DOWN the descending top(it will work when the inside is set)
14#: GND feedback set 8 GND
15#: GF8 feedback set 8 input top (−5V~+5V)
16#: GND feedback set 7 GND
17#: GF7 feedback set 7 input top (−5V~+5V)
18#: GND feedback set 6 GND
19#: GF6 feedback set 6 input top (−5V~+5V)
20#: GND feedback set 5 GND
21#: GF5 feedback set 5 input top (−5V~+5V)

5
22#: GND feedback set 4 GND
23#: GF4 feedback set 4 input top (−5V~+5V)
24#: GND feedback set 3 GND
25#: GF3 feedback set 3 input top (−5V~+5V)
26#: GND feedback set 2 GND
27#: GF2 feedback set 2 input top (−5V~+5V)
28#: GND feedback set GND
29#: GF1 feedback set 1 input top (−5V~+5V)
30#: V1 the 1st unit output top (0~10V)
31#: GND the 1st GND
32#: V2 the 2nd unit output top (0~10V)
33#: GND the 2nd GND
34#: V3 the 3rd unit output top (0~10V)
35#: GND the 3rd GND
36#: V4 the 4th unit output top (0~10V)
37#: GND the 4th GND
38#: V5 the 5th unit output top (0~10V)
39#: GND the 5th GND
40#: V6 the 6th unit output top (0~10V)
41#: GND the 6th GND
42#: V7 the 7th unit voltage output top (0~10V)
43#: GND the 7th GND
44#: V8 the 8th unit output top (0~10V)
45#: GND the 8th GND
46#: +5V
47#: GND providing the outside feedback power
48#: −5V
49#: NC empty
50#: TB2 the output normally closed contacts of the relay J2
51#: TA2 The output common port of the relay J2
52#: TC2 the output normally open consumption of the relay J2
53#: TB1 the output normally closed contacts of the relay J1
54#: TA1 The output common port of the relay J1
55#: TC1 the output normally open consumption of the relay J1
56#: NC empty
57#: L the working power input top: AC220V.
58#: N the working power input top: AC220V.

6
IV. the diagram of the top
G F1 29 30 V1
S1 U1
Feedback
反馈给定1 28 31
单元一输出
F1 Unit 1 output
GF2 27 32 V2
S2 U2
Feedback
反馈给定2 26 33 单元二输出
F2
34 V3
Unit 2 output
G F3 25
S3 U3
Feedback
反馈给定3 24 35
单元三输出
G F4 23
F3
36 V4 Unit 3 output
S4 U4
反馈给定4
Feedback 22 单元四输出
37
F4 Unit 4 output
GF5 21
S5 38 V5
U5 单元五输出
反馈给定5
Feedback 20 39 Unit 5 output
GF6 F5 V6
19 40
S6 U6 单元六输出
反馈给定6 18 41
Feedback F6
Unit 6 output
GF7 17 42 V7
S7 U7
反馈给定7 16 单元七输出
43
Feedback GF8 15 F7 Unit 7 output
44 V8
S8 U8
反馈给定8 45 单元八输出
14
Feedback 13
F8 46 +5V Unit 8 output
+5V
+10V 12 47 GND
反馈电源
11 - 5V
48 -5V Feedback power
外部主
Out main G2 10 49
set II给定二
G1 9 50 TB 2
Out 外部
main主 J2
8 51 TA2
set 给定
I 一 Relay
继电 器2输2 output

+10V 7 52 TC2
UP 6 53 T B1
J1
GS 5 54 TA1
+5V 继 电器1输出
Failure chain
故障 连锁 ERR 4 55 TC 1 Relay 1 output
+24 3 +24V 56
GS
RS 2 57 L
+5V
启动 GS 1 -5V 电源 板 58 N 220V电 源
Start up +10V PIP 220V power

端子图
The diagram of the top

V. the operations of the panel

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Pilot lamp H1 Shift

Add or subtract
Pilot lamp H2
Function
display

58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31

30

1. the instructions of the panel


a) Function key (ENTER): The parameter value of the
corresponding function keys can be read with this key.
b) Add and subtract key (  ): The two keys is to change the
value of the function code and the parameters when we set the
functions.

7
c) Shift key (RESET): Using this key can make the system quit
from the parameters-set state or replace with failure.
d) Display: It will display the value of the units when the system
is running. And it will display the function code and the
parameter value when the system is in the function set state.
e) Pilot lamp H1: When the lamp is off, the system is in the
stopping state.
When the lamp is on, the system is in the running state.
f) f) Pilot lamp H2: When the lamp is off, the system is running
normally.
When the lamp is on, the system is running with failure.
2. the typical operation examples
eg.1: change the inside set voltage value F34 (change the set
value 5.00V to 1.00V)
a) Press the ENTER key and it will display F00;
b) Press the key , and when it displays F34 leave the key ;
c) Press the ENTER key again and it will display the voltage value 5.00;
d) Press  or  until it displays 1.00.
e) Press the ENTER key and it will display F34. If the parameters
are prevented to change, it will display Err; press the ENT key
again and it will display F34. At the moment F34 will remain the
initial value 5.00.
f) Press the RESET key to back to the normal state: 0.00.

VI. the parameters


the schedule of the parameters and functions
FXX Functions Instructions Original
set
00 Quit from the function-set state 0: the set fountain is inside main
set
01 The 1st unit set fountain 1~8: the set fountain is the output
9
02 The 2nd unit set fountain of 1~8 units(except this unit) 9
9: the set fountain is the outside
03 The 3rd unit set fountain 9
main set I
04 The 4th unit set fountain 9
10: the set fountain is the outside
05 The 5th unit set fountain 9
main set II
06 The 6th unit set fountain 9
F: this unit is in no use and the
07 The 7th unit set fountain 9
unit output is zero
08 The 8th unit set fountain 9
09 The 1st unit feedback fountain 1~8: the feedback fountain is the F
10 The 2nd unit feedback fountain outside feedback set 1~8 2
11 The 3rd unit feedback fountain F: this route has no feedback 3

8
12 The 4th unit feedback fountain input 4
13 The 5th unit feedback fountain 5
14 The 6th unit feedback fountain 6
15 The 7th unit feedback fountain 7
16 The 8th unit feedback fountain 8
17 The 1st unit set proportion The range of the proportion: 1.00
18 The 2nd unit set proportion 0.00~15.00 1.00
19 The 3rd unit set proportion (accurate to the second decimal 1.00
20 The 4th unit set proportion place) 1.00
21 The 5th unit set proportion 1.00
22 The 6th unit set proportion 1.00
23 The 7th unit set proportion 1.00
24 The 8th unit set proportion 1.00
25 The 1st unit feedback proportion The range of the proportion: 0.40
26 The 2nd unit feedback proportion 0.00~15.00 0.40
27 The 3rd unit feedback proportion (accurate to the second decimal 0.40
28 The 4th unit feedback proportion place) 0.40
29 The 5th unit feedback proportion 0.40
30 The 6th unit feedback proportion 0.40
31 The 7th unit feedback proportion 0.40
32 The 8th unit feedback proportion 0.40
33 Outside main setinput style 0: electric current input 1
choice 1: voltage input
34 The inside main set value Range: 0.00~10.00(V) 5.00
(if input is bigger than 10V,
regard as 10V)
35 The speed ascending time Range: 0~100(s) 10
36 The speed descending time (if input is longer than 10s, 10
regard as 100s)
37 The display proportion Range: 0.01~15.00 1.00
coefficient
38 Normal state display 0: when running, displaying 9
Contents choice “run”
When stopping, displaying
“scd”
1~8: displaying the output value
of 1~8 units
9~16: the input value of 1~8
units
39 Initial operation 1: the initial value
40 Parameters locked 0: to modify the parameters 0
1: parameters locked(it cannot be

9
modified)
41 Set upper limit Range: 0.00~10.00 10.00
42 Set lower limit Range: 0.00~10.00 0.00
43 Inside set style Range: 0, 1 0
Refer to the detail instructions.
44 Regulation of the rise and drop Range: 0.01~4.00 0.20
step length of inside set

VII. the detail instructions of the parameters


1. F00 enter, quit function set state
In the working state, press “ENTER”, and the display will displays
“RESET” and enter to the parameters-set state. In the parameters
number displaying state: displaying “F00”, press “ENTER” to back to
working state. When the parameters number is not F00, press RESET
to back to working state.
2. F01~F08 set the set fountain of units 1~8
The set range: 0~10, F
F01 sets the 1st unit fountain, F02 sets the 2nd unit fountain…F08 sets
the 8th fountain. There are 10 input fountains altogether that is 3 main
set fountains and the other 7 units output except this unit. The units
can be connected as any in series or parallel connection through the
parameters set.
0: Setting this unit set fountain is the inside main set GD, and the range
of GD is 0.00~10.00;
Setting this unit set fountain is the input V1~V8 of the units 1~8,
1 and the range of Vi is 0.00~10.00. Do not regard the output of this
~

unit as the input fountain please that is the output of this unit
8 remains the same which will not change as the main set changes.
e.g.: Set F01 to 1 that is the set fountain G1 of the 1st unit is the
output V1 of the 1st unit. In another word, the output value is
locked and cannot change.
9: Setting this unit set fountain is the outside main set I GD1, and the
range of GD1 is 0.00~10.00V;
10. Setting this unit set fountain is the outside main set II GD2, and the
range of GD2 is 0.00~10.00V;
F: It is not used in this unit and the unit output is zero.
3. F09~F16 setting the feedback fountain of the units 1~8
The set range: 1~8, F
F09 sets the feedback fountain of the 1st unit, F10 sets the feedback
fountain of the 2nd unit…F16 sets the feedback fountain of the 8th unit.
There are 8 routes feedback fountains GF1~GF8.
1~8: Setting this unit feedback fountain is the outside feedback set
GF1~GF8, and the range of GFi is −5.00V~+5.00V;
10
F: Setting this route do not need feedback.
e.g.: Set F09 to 2 that is the feedback fountain of the 1st unit is the
outside feedback set GF2.
Note: In the multistation connection, the next lower level set unit
cannot use feedback.
4. F17~F24 setting the set proportion of the units 1~8
The set range: 0.00~15.00
F17 sets the 1st unit set proportion KS1, F18 sets the 2nd unit set
proportion KS2…F24 sets the 8th unit set proportion KS8.
e.g. Set F17 to 2.00 that is the set proportion of the 1st unit is
KS1=2.00.
Note: In the multistation connection, the set proportion of the next
lower level set unit is to be set to 1.
5. F25~F32 setting the feedback proportion of the units 1~8
The set range: 0.00~15.00
F25 sets the 1st unit feedback proportion KF1, F26 sets the 2nd unit
feedback proportion KF2…F32 sets the 8th unit feedback proportion
KF8.
e.g.: Set F25 to 2.00 that is the 1st unit feedback proportion KF1=2.00.
6. F33 outside main set—input styles choice
The set range: 0, 1
0: The input of the outside main set I GD1 is in current style, and the
range is 4~20mA;
1: The input of the outside main set II GD2 is in voltage style, and the
range is 0.00~10.00V.
7. F34 the initial value of the inside main set
The range: 0.00~10.00
The range of the initial value of the inside main set is 0.00~10.00. If
the input is bigger than 10.00, regard it as 10.00.
In the following two situations, F34 is assigned to GD:
1) the synchronous adjuster is in power state
2) F34 parameters modified successfully
8. F35, F36 the ascending and descending time of the set speed the set
range: 0~100s
F35: Set the ascending to the time the main set from 0.00V to 10.00V
needs;
F36: Set the descending to the time the main set from 10.00V to 0.00V
needs;
The parameters will work when start up, stop and timing. In addition,
set the start-up time and the stop time before starting up and stopping.
If the start-up is slow or the time is changed in the course of stopping,
there will be no effect to the starting up and stopping. The new set
time will work only in the next starting up and stopping.
11
Note: In the concatenation, in order to hold the dynamic ascending and
descending time synchronous, the ascending and descending of each
synchronous adjuster must remain the same.
9. F37 setting the display proportion
the set range: 0.00~15.00
Set the display proportion to make it have physical meaning. If you
do not use this function set it to 1.
Display value = fact value * display proportion (F37)
10. F38 setting the display contents the set range: 0~16
0: displaying the system state, RUN when running;
SCD when stopping
st
1: set to displaying the 1 unit output;
2: set to displaying the 2nd unit output;
3~8: set to displaying the 3rd to the 8th units output;
9: set to displaying the 1st unit set;
10: set to displaying the 2nd unit set;
11~16: set to displaying the 3rd to the 8th units set.
11. F39 setting all the parameters to the initial value
In the parameters-set state, change the parameter number to F39, and
press ENTER to finish reposition to the initial.
Note: After the reposition, the parameters that the users set will all be
missing. If there are some important parameters please copy first.
12. F40 setting the parameters lock the set range: 0~1
0: The parameters can be modified.
1: Set it to 1, the parameters will be locked and the users cannot change
it. If it is necessary to modify the parameters please set it to 0.
13. F41 setting the main set upper limit
The set range: 0.00~10.00V
F42 setting the main set lower limit
the set range: 0.00~10.00V
F41 is the set upper limit, and F42 is the set lower limit. The
following s are the functions.
14. F44 the key step length(sensitivity set parameter)
The set range: 0.01~4.00
When using the outside keys to ascend and descend, the tolerant value
of the parameter  adjusting the sensitivity of the keys and the
ascending and descending timeis 0.20 that is about 10 seconds of
ascending and descending time. When the adjusting range of the
sensitivity is more than the adjusting speed of the rise and drop, adjust
by the rise and drop time. If the sensitivity parameter is less than the
descending time, adjust by the sensitivity.

12

F41 when Gi > F41
Gi = Gi when F42 ≤ G ≤ F41
F42 when Gi < 42
In the formula:
Gi is the main set GD, GD1 and GD2 of the synchronous controller;
Gi is the value bounded by the upper limit and the lower limit;
F41 the main set upper limit;
F42 the main set lower limit
F42≤Gi≤41 F42≤Gi≤F41
Gi’
Gi>F41
Gi<F42
F41

F42
t

RS

t
Start up stop

VIII. the multistation connection and the notice


When there are more than 8 JGD-280 synchronous controllers, the user
can connect them together. If there N controllers, they are called number
1~N synchronous controllers. So we can choose any unit of the 1st controller
to control the main machine. The output of this unit woks as the main set of
the 2nd controller to connect to the out main set I or out main set II to the 2nd
controller. Now the proportion coefficient should be set to 1.00 and this unit
has no feedback.
Explanations:
This example chooses JGD280 and JGD240 controller to connect
together. And there are at most 11 machines in this kind of connection.
JGD280 is regarded as the 1st controller and JGD240 is regarded as the 2nd
controller. The first unit of the 1st controller controls the main machine and
at the same time this unit output works as the outside set input of the next
lower level synchronous controller. The input fountain of the first unit of the
1st controller is set to 9(outside set I), and the output proportion coefficient is
set to 1.00. That is to say the input voltage of the out set I of the 1st
controller transfers to the 2nd controller as the out set of it. By analogy,
multistation of the controller can be connected.
Notice:
The first unit of the other controllers are not used to control the
machine generally except the first unit of the 1st controller. Otherwise the
input voltage and the rev of the machine controlled will be the same with the
mainframe.

13
~220V

+10N V01 V11 V01 To next level


GND GND transducer1 GND GND
1 s t co nt r ol l e r
V11 +5V

2 n d Co nt ro ll e r
+5V V02 -5V V02
-5V Transducer 2 Vp2 transducer1
Vp2
Transducer 2

Transducer
V0 Transducer 3

sensor
V V0 sensor
V V0
IX. the adding advice of the JGD 280A parameters
1. the feedback upper and lower limits instructions:
F45 1st unit feedback upper limit range: 0~+5V initial value: +5V
nd
F46 2 unit feedback upper limit range: 0~+5V initial value: +5V
rd
F47 3 unit feedback upper limit range: 0~+5V initial value: +5V
th
F48 4 unit feedback upper limit range: 0~+5V initial value: +5V
th
F49 5 unit feedback upper limit range: 0~+5V initial value: +5V
th
F50 6 unit feedback upper limit range: 0~+5V initial value: +5V
th
F51 7 unit feedback upper limit range: 0~+5V initial value: +5V
th
F52 8 unit feedback upper limit range: 0~+5V initial value: +5V
st
F53 1 unit feedback lower limit range: −5V~0 initial value: −5V
nd
F54 2 unit feedback lower limit range: −5V~0 initial value: −5V
rd
F55 3 unit feedback lower limit range: −5V~0 initial value: −5V
th
F56 4 unit feedback lower limit range: −5V~0 initial value: −5V
th
F57 5 unit feedback lower limit range: −5V~0 initial value: −5V
th
F58 6 unit feedback lower limit range: −5V~0 initial value: −5V
th
F59 7 unit feedback lower limit range: −5V~0 initial value: −5V
th
F60 8 unit feedback lower limit range: −5V~0 initial value: −5V
F61 passwords set range: 000~999 initial value: 000
F62 feedback alerting delay set range: 000~200 initial value: 050
2. the feedback upper and lower limits do not work in the following
situations:
1) The system does not start up;
2) The feedback is set to F;
3) The feedback upper limit does not work when it is set to +5V;
4) The feedback lower limit does not work when it is set to −5V;
5) The main set is set to 0.00V.
3. alerting display
If the nixie tube displays Er88, the first two stand for alerting, and the third
stands for the unit number of the concrete failure. The upper of the fourth
displays  which shows the upper limit alerts. The lower of it displays 
which shows the lower limit alerts.

14
4. unload the alerting
1) Press the RESET key;
2) Make a short circuit of the out tops 4# and 5#.
5. the feedback alerting time set:
The feedback alerting delaying 0~50 is about 1 second, and when the set is
000 the feedback alerting has no time lag.
6. passwords set:
1) Press the ENTER key to display P000, press it again to display F00,
2) Press ∆ and ∇ until it displays F61, and press ENTER to display P000,
3) Press ∆ and the number will increase. Stop until the number you want
to set.
4) Press ENTER and the passwords are set.
If you do not use the passwords, set F61 to 000.
Special cue: If you have set the passwords, please commit it to your
memory.
7. unfold the passwords
Press ENTER to display P000, and press ∆ to display the set
passwords. Press ENTER to display F01 and the passwords have been
unfolded.
Universal passwords: 992
Good cue: Do not tell the universal passwords to anyone.

X. the failure overhaul and the maintenance


The user must follow the working conditions and methods of the
instructions to operate the JGD series controller. The controller is
guaranteed 1 year from the date the user buys.
In the course of normal working state, if the controller is out of the
way, please refer to the following list to estimate the failure reason and
rectify the trouble. If the trouble can not be rectified following the list,
contact our company or the dealer.
Failure details Reason resolvment
Displaying Err1 There is out failure signal input(a short Check the out failure.
circuit of ERR and GS)
Displaying Err2 There is no input fountain in the Reset the corresponding
controlling unit. parameters, and check the
contents of the input fountain
Vi of each route.
Displaying Err3 The controller memory bank fails. Reset to the initial value.
Some unit does not There is no start-up signal input(no short Check the out start-up signal.
feedback circuit of R/S and GS)
The input fountain of this unit is wrong. Check and modify the
contents of the input fountain
of each route.
The output proportion coefficient of this Check and modify the
unit is wrong. contents of the output

15
proportion coefficient of each
route.
The out set input is wrong. Check the value of V11 and
V12.
The inside set value is wrong. Check the set value of inside
voltage.
The feedback set of this unit is wrong. Check the relevant feedback
fountain Vf of each route
output.
The feedback proportion coefficient of Check and modify the
this unit is wrong. feedback proportion
coefficient Kf1 of each route.
The feedback signal input is wrong. Check the feedback signal of
the feedback input top and
feedback link.

XI. the figure measurement


290
110
100
100

85

300×110×110

16