Elective Selection of Relays
Elective Selection of Relays
Whydoweneedaprotectiverelay?
A protective relay device senses an abnormal condition in an
electrical circuit and proactively closes the contact.Substation
protection is designed to protect substation equipment, the lines
supplying the substation's power, and the lines leaving the substation.It
helps in quickly detecting faults and de-energizing the affected parts of
the system, reducing the risk of electric shock, fire, and other accidents
WhyProtectiveRelaysMatter:
Safety:
Prevent Fires: A shortcircuit can generateintense heat,potentially
leadingtofires.Protectiverelays quicklyisolatethefault,preventing the
spread of fire. [4]
Reliability:
Minimize Downtime: Faulty sections of the system can cause
power outages. Protective relays quickly isolate the problem,
minimizing downtime and ensuring continuous power supply. [5]
Cost-Effectiveness:
Prevent Equipment Damage: Faults can cause irreparable damage
to expensive equipment. Protective relays prevent this damage,
saving significant repair costs. [3]
Reduce Maintenance Costs: By preventing damage and downtime,
protective relays reduce the need for costly repairs and
maintenance. [1]
TypesofFaultsinDistributionSubstations
Distribution substation faults can interfere with equipment, the power
supply, andthestabilityof theentire system. Common fault categories consist
of:
2. Overload faults: These occur when the load is greater than the
substation's capacity, which can cause transformers and other equipment to
overheat and perhaps sustain damage.
3. Earth (Ground) faults: When a phase conductor comes into touch with the
ground, a single-phase fault happens. This causes current to leak and lowers
system performance.
Systemvoltage,Typeofequipment,sensitivityandspeed,costvs.reliability.
SystemVoltage
The system voltage refers to the nominal voltage level at which the electrical
system operates. This is a fundamental factor in relay selection, as relays are
designed to function within specific voltage ranges.
For example, a relay intended for a low-voltage system (e.g., 480 volts)would
not be suitable for a high-voltage system (e.g., 13.8 kilovolts). Relays must be
compatible with the system voltage to ensure accurate operation and prevent
damage.
TypeofEquipment
SensitivityandSpeed
Speed refers to the time it takes for the relay to respond to a fault and initiate
the tripping action of the circuit breaker. Faster response times minimize the
duration of the fault, reducing the risk of damage to equipment and disruption
to the system.
Costvs.Reliability
Summary
https://www.csqelectric.com/types-of-protection-relays/
https://econtroldevices.com/choosing-the-perfect-relays-a-comprehensive-
guide-to-meeting-your-specific-requirements/
https://www.t-d-services.com/our-services/power-delivery-2/protective-
relaying/#:~:text=A%20protective%20relay%20device%20senses,the%20lines%2
0leaving%20the%20substation.
https://www.eeeguide.com/protective-relay/