Data Sheet VA520 EN
Data Sheet VA520 EN
Option:
• Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy man-
agement systems, building management systems, PLC,...
• Easy and affordable installation
• Units freely selectable via keys on the display m³/h, m³/min, l/min, l/s, kg/h, kg/min, kg/s, cfm
• Compressed air counter up to 1,999,999,999 m³ can be reset to “zero” via keypad
• Analog output 4...20 mA, pulse output (electrically isolated)
• High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
• Negligibly small loss of pressure
• Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
• Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./
min values °C, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
86 www.cs-instruments.com
Flow
1/4“ 3/8“ 1/2" 3/4" 1" 1 ¼" 1 ½" 2" 2 ½" 3"
l/min (cfm) m³/h (cfm) m³/h (cfm) m³/h (cfm) m³/h (cfm) m³/h (cfm) m³/h (cfm) m³/h (cfm) m³/h (cfm) m³/h (cfm)
Low-Speed (50 m/s) 25 (0,9) 225 Nl/min (8) 20 (14) 45 (25) 75 (45) 140 (80) 195 (115) 320 (190) 550 (325) 765 (450)
Air
Standard (92,7 m/s) 50 (1,8) 25 (14,7) 45 (25) 85 (50) 145 (85) 265 (155) 365 (215) 600 (350) 1025 (600) 1420 (835)
Max (185 m/s) 105 (3,6) 50 (29,4) 90 (50) 175 (100) 290 (170) 530 (310) 730 (430) 1195 (700) 2050 (1205) 2840 (1670)
High -Speed (224 m/s) 130 (4,5) 60 (35,3) 110(60) 215 (125) 355 (210) 640 (375) 885 (520) 1450 (850) 2480 (1460) 3440 (2025)
Low-Speed (50 m/s) 45 (1,5) 330 Nl/min (11,7) 35 (20) 75 (40) 120 (70) 220 (130) 305 (180) 505 (295) 865 (510) 1200 (705)
Argon Standard (92,7 m/s) 85 (3) 35 (20,5) 70 (40) 135 (80) 230 (135) 415 (245) 570 (335) 935 (550) 1605 (945) 2225 (1310)
(Ar) Max (185 m/s) 170 (6) 75 (44,1) 140 (80) 275 (160) 460 (270) 830 (485) 1140 (670) 1870 (1100) 3205 (1885) 4440 (2615)
High-Speed (224 m/s) 205 (7,2) 95 (55,9) 170 (100) 335 (195) 555 (325) 1005 (590) 1385 (815) 2265 (1330) 3880 (2285) 5380 (3165)
Low-Speed (50 m/s) 25 (0,9) 225 Nl/min (7,9) 20 (14) 45 (25) 75 (45) 140 (80) 195 (115) 320 (185) 545 (320) 760 (445)
Carbondi- Standard (92,7 m/s) 50 (1,8) 25 (14,7) 45 (25) 85 (50) 145 (85) 260 (155) 360 (210) 590 (345) 1015 (595) 1405 (825)
oxide
(CO2) Max (185 m/s) 105 (3,6) 50 (29,4) 90 (50) 175 (100) 290 (170) 525 (305) 720 (425) 1185 (695) 2030 (1190) 2810 (1655)
High-Speed (224 m/s) 130 (4,5) 60 (35,3) 105 (60) 210 (125) 350 (205) 635 (370) 875 (515) 1430 (840) 2455 (1445) 3405 (2000)
Low-Speed (50 m/s) 25 (0,9) 205 Nl/min (7,2) 20 (13) 40 (25) 70 (40) 130 (75) 180 (105) 295 (175) 505 (300) 705 (415)
Nitrogen Standard (92,7 m/s) 50 (1,5) 20 (11,7) 40 (20) 80 (45) 135 (75) 240 (140) 335 (195) 550 (320) 945 (555) 1305 (770)
(N2) Max (185 m/s) 100 (3,3) 45 (26,4) 80 (45) 160 (95) 270 (155) 485 (285) 670 (395) 1100 (645) 1885 (1110) 2610 (1535)
High-Speed (224 m/s) 120 (4,2) 55 (32,3) 100 (55) 195 (115) 325 (190) 590 (345) 815 (475) 1330 (780) 2280 (1340) 3165 (1860)
Low-Speed (50 m/s) 25 (0,9) 215 Nl/min (7,5) 20 (13) 45 (25) 75 (40) 135 (80) 185 (110) 305 (180) 525 (310) 730 (430)
Oxygen Standard (92,7 m/s) 50 (1,8) 20 (11,7) 40 (25) 80 (45) 140 (80) 250 (145) 345 (205) 570 (335) 980 (575) 1355 (795)
(O2) Max (185 m/s) 100 (3,6) 45 (26,4) 85 (50) 165 (95) 280 (165) 505 (295) 695 (410) 1140 (670) 1955 (1150) 2710 (1590)
High-Speed (224 m/s) 125 (4,2) 55 (32,3) 105 (60) 205 (120) 340 (200) 610 (360) 845 (495) 1380 (810) 2365 (1390) 3280 (1930)
Low-Speed (50 m/s) 25 (0,9) 220 Nl/min (7,7) 20 (14) 45 (25) 75 (45) 140 (80) 190 (110) 315 (185) 540 (320) 750 (440)
Nitrous Standard (92,7 m/s) 50 (1,8) 20 (11,7) 40 (25) 85 (50) 140 (85) 260 (150) 355 (210) 585 (345) 1005 (590) 1395 (820)
oxide
(N2O) Max (185 m/s) 105 (3,6) 45 (26,4) 85 (50) 170 (100) 285 (170) 520 (305) 715 (420) 1170 (690) 2010 (1180) 2785 (1640)
High-Speed (224 m/s) 125 (4,5) 60 (35,3) 105 (60) 210 (120) 345 (205) 630 (370) 865 (510) 1420 (835) 2435 (1430) 3375 (1985)
Low-Speed (50 m/s) 15 (0,6) 130 Nl/min (4,5) 14,4 (8) 25 (15) 45 (25) 85 (50) 115 (65) 190 (110) 325 (190) 450 (265)
Natural gas Standard (92,7 m/s) 30 (0,9) 14 (8,8) 25 (15) 50 (30) 85 (50) 155 (90) 215 (125) 355 (205) 605 (355) 840 (495)
(NG) Max (185 m/s) 60 (2,1) 25 (14,7) 50 (30) 105 (60) 170 (100) 310 (185) 430 (250) 705 (415) 1210 (710) 1680 (985)
High-Speed (224 m/s) 75 (2,7) 35 (20,5) 65 (35) 125 (70) 210 (120) 380 (220) 520 (305) 855 (500) 1465 (865) 2035 (1195)
There are different options available for connection to modern Bus systems:
www.cs-instruments.com 87
Flow
Reference standard
H1 20 °C, 1000 mbar
H2 0 °C, 1013.25 mbar
H3 15 °C, 981 mbar
H4 15 °C, 1013.25 mbar
Maximum pressure
K1 16 bar
K2 40 bar
88 www.cs-instruments.com
Flow
DESCRIPTION (Flange version) / Stainless steel 1.4404 ORDER NO. TECHNICAL DATA VA 520
VA 520 flow meter with integrated DN 15 measuring section with flange 0695 2521 Parameters: m³/h, l/min (1000 mbar,
VA 520 flow meter with integrated DN 20 measuring section with flange 0695 2522 20 °C) in case of com-
pressed air or Nm³/h, Nl/min
VA 520 flow meter with integrated DN 25 measuring section with flange 0695 2523
(1013 mbar, 0 °C) in case
VA 520 flow meter with integrated DN 32 measuring section with flange 0695 2526 of gases
VA 520 flow meter with integrated DN 40 measuring section with flange 0695 2524 Units adjustable via m³/h, m³/min, l/min, l/s, ft/
VA 520 flow meter with integrated DN 50 measuring section with flange 0695 2525 keys at display: min, cfm, m/s, kg/h, kg/min,
VA 520 flow meter with integrated DN 65 measuring section with flange 0695 2527 g/s, lb/min, lb/h
VA 520 flow meter with integrated DN 80 measuring section with flange 0695 2528 Sensor: Thermal
mass flow sensor
Measured medium: Air, gases
Gas types are adjust- Air, nitrogen, argon, CO2,
DESCRIPTION ORDER NO. ORDER NO. able over CS service oxygen
Stainless steel Stainless steel
software or CS data
1.4404 1.4301 logger:
VA 520 flow meter with 1/4" measuring section 0695 1520 0695 0520
Measuring range: See table above
VA 520 flow meter with 3/8” measuring section 0695 1527 0695 0527
Accuracy: ± 1.5% of m.v. ± 0.3% of f.s.
VA 520 flow meter with 1/2" measuring section 0695 1521 0695 0521 (o. M. V. = of measured on request:
VA 520 flow meter with 3/4" measuring section 0695 1522 0695 0522 value) ± 1% of m.v. ± 0.3% of f.s.
(o. F. S. = of full scale)
VA 520 flow meter with 1" measuring section 0695 1523 0695 0523
Operating temperature: -30…80 °C
VA 520 flow meter with 1 1/4" measuring section 0695 1526 0695 0526
-20...80 °C with pressure
VA 520 flow meter with 1 1/2" measuring section 0695 1524 0695 0524 sensor
VA 520 flow meter with 2" measuring section 0695 1525 0695 0525 Operating pressure: -1 to 16 bar optionally up to
PN 40
Digital output: RS 485 interface, (Mod-
bus-RTU), optional: Ethernet
ACCESSORIES ORDER NO.
interface PoE), M-Bus
ISO calibration certificate (5 calibration points) for VA sensors 3200 0001
Analogue output: 4…20 mA for m³/h or l/min
Additional calibration curve stored in the sensor Z695 5011
Pulse output: 1 pulse per m³ or per litre
Certificate of origin Z695 5012
electrically isolated. Pulse
Closing cap for measuring section in aluminium 0190 0001 weight can be set on the
Closing cap for measuring section stainless steel 1.4404 0190 0002 display.
Alternatively, the pulse
Connection cable for VA/FA series, 5 m 0553 0104 output can be used as an
Connection cable for VA/FA sensors, 10 m 0553 0105 alarm relay
Ethernet connection cable length 5 m, 0553 2503 Supply: 18…36 VDC, 5 W
M12 plug x-coded (8 pin) to RJ 45 plug
Burden: < 500 Ω
Ethernet connection cable length 10 m, 0553 2504
Housing: Polycarbonate (IP 65)
M12 plug x-coded (8 pin) to RJ 45 plug
Measuring section: Stainless steel, 1.4404 or
1.4301
For further accessories refer to pages 106-110 Mounting position: any
www.cs-instruments.com 89
Flow
VA 520 - Thread
Connection thread Outer pipe Inner pipe L L1 H H1 A
mm mm mm mm mm mm mm
R 1/4″ 13.7 8.9 194 137 174.7 165.7 15
R 3/8″ 17,2 12,5 300 200 175 165,7 15
R 1/2″ 21.3 16.1 300* 210 176.4 165.7 20
R 3/4″ 26.9 21.7 475* 275 179.2 165.7 20
R 1″ 33.7 27.3 475* 275 182.6 165.7 25
R 1 1/4″ 42.4 36.0 475* 275 186.9 165.7 25
R 1 1/2″ 48.3 41.9 475* 275 186.9 165.7 25
R 2″ 60.3 53.1 475* 275 195.9 165.7 30
*Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site!
90 www.cs-instruments.com