SINGLE LINE DIAGRAM USE 2 - 50mm² THHN + 1-50mm2

LOAD SCHEDULE 230 VAC, 1 PHASE M


PROTECTION
RATING SIZE WIRE/PIPE
CKT. B. RATING
CIRCUIT NUMBER LOAD DESCRIPTION USE 2 - 50 mm² THHN + 1 - 50 mm²
VOLT - mm2 mm2
VOLT AMPERE A.T. POLE THHN
AMPERE (THHN) PIPE
1 2.5 HP – A.C.U. 3335 230 25.375 5.5 15 30 2
2 2.5 HP – A.C.U. 3335 230 25.375 5.5 15 30 2
150 AT
3 2.5 HP – A.C.U. 3335 230 25.375 5.5 15 30 2 30 AT 30 AT
4 1HP – A.C.U. 1840 230 14 3.5 15 20 2 A.C.U 1 2 A.C.U
30 AT 20 AT
5 1HP – A.C.U. 1840 230 14 3.5 15 20 2
A.C.U 3 4 A.C.U
6 1HP – A.C.U. 1840 230 14 3.5 15 20 2 20 AT 20 AT
7 LIGHTING OUTLET 2666.6 230 14.49 2.0 15 15 2 A.C.U 5 6 A.C.U
15 AT 15 AT
8 LIGHTING OUTLET 2666.6 230 14.49 2.0 15 15 2 L.O 7 8 L.O.

15 AT 15 AT
9 LIGHTING OUTLET 2666.6 230 14.49 2.0 15 15 2
L.O 9 10 L.O.
10 LIGHTING OUTLET 2666.6 230 14.49 2.0 15 15 2 15 AT 15 AT
11 LIGHTING OUTLET 2666.6 230 14.49 2.0 15 15 2 L.O. 11 12 L.O.

15 AT 20 AT
12 LIGHTING OUTLET 2666.6 230 14.49 2.0 15 15 2 L.O 13 14 C.O
13 LIGHTING OUTLET 2666.6 230 14.49 2.0 15 15 2 15 AT 20 AT
15 16
14 LIGHTING OUTLET 2666.6 230 14.49 2.0 15 15 2 L.O C.O

20 AT 20 AT
15 LIGHTING OUTLET 2666.6 230 14.49 2.0 15 15 2 C.O 17 18 SPARE

16
17
CONVENIENCE OUTLET
CONVENIENCE OUTLET
1500
1500
230
230
6.52
6.52
3.5
3.5
15
15
20
20
2
2
LEGEND
-CIRCULAR LED LAMP, 40W

S1 -ONE GANG SWITCH


S2bc -TWO GANG SWITCH, LETTER INDICATES LIGHT CONTROLLED

LOCATION PLAN S3def


S3W gh
-THREE GANG SWITCH, LETTER INDICATES LIGHT CONTROLLED
-THREE -WAY SWITCH, LETTER INDICATES LIGHT CONTROLLED
-CONVENIENCE OUTLET
SAINT JAMES
PARK
PA
N-
SPECIFICATIONS -AIR CONDITIONING UNIT OUTLET
PH
IL
RA
M
ACU
IP O
PI N
CA
NE
LA
HW
Y
G
O
S
ALL ELECTRICAL WORKS AND EQUIPMENT SHALL CONFORM WITH THE LATEST EDITION OF THE PHILIPPINES ELECTRICAL CODE – PART, LEYECO II,
ST

STA. MARGARITA NATIONAL


. BUREAU OF FIRE PROTECTION AND RA 7820 (NEW ELECTRICAL ENGINEERING LAW)
HIGHSCHOOL
AZ
AN 1. ALL INSTALLATION/CONSTRUCTION WORKS SHALL BE UNDER SUPERVISION OF A REGISTERED ELECTRICAL ENGINEER (REE)/PROFESSIONAL -SERVICE ENTRANCE
ZA
ST ELECTRICAL ENGINEER (PEE) OR REGISTERED ELECTRICIAN (RME)
.

THIS SITE 2.
3. MINIMUM SIZE WIRE SHALL BE 2 mm2 (No. 14 AWG) AND 3.5 mm2 (No. 12 AWG)
FOR LIGHTING AND CONVENIENCE OUTLETS, RESPECTIVELY -CIRCUIT BREAKER
CLARENCIO
.
ST

Y CALAGOS
TA

HW MEMORIAL SCHOOL 4. MAIN SERVICE ENTRANCE SHALL BE 325 mm2 THW at 80 mm ø RSC
-GROUND/EARTH
O

NE
YN

RA
M PI OF FISHERIES
P.

O
N IP
PA CA IL
N- LA PH UNLESS SHOWN IN THE PLAN, ALL WIRING SHALL BE IN STANDARD RSC. PIPE/EMT INSTALLED INSIDE THE CEILING OR RUN EMBEDDED INSIDE
N-
.

PH
ST

G
AZ
IL
O
S PA WALLS OR UNDER FLOOR M -KILOWATT-HOUR METER
S

AN IP ST
TE

ZA PI .
AN

ST NE
RR

. HW
5. EQUIPMENT SHALL INSTALLATION:
BA

Y
SWITCHES/CONVENIENCE OUTLETS/ACU OUTLETS/PANEL BOARD SHALL BE FLUSH MOUNTED
7 -CIRCUIT HOME RUN

6.
7. MOUNTING HEIGHT OF EQUIPMENT:
CONVENIENCE OUTLETS - 300mm ABOVE FINISH FLOOR LINE -PANEL BOARD
SWITCH OUTLETS - 1500mm ABOVE FINISH FLOOR LINE
ACU OUTLETS - LEFT HAND SIDE OF ACU UNIT
PANEL BOARD - 1500mm ABOVE FINISH FLOOR LINE
BODY OF WATER

NORTH

UNIVERSITY: PREPARED BY: PROFESSIONAL ELECTRICAL ENGINEER PRC NO. PROJECT TITLE. APPROVED BY: SHEET CONTENT SHEET NO.
TIN

EVSU JOSHUA STEPHEN BESARIO ENGR. VINYL HO OQUINO


PTR NO.
ISSUED:
SMALL COMMERCIAL
2
DATE: LOCATION: EASTERN VISAYAS STATE UNIVERSITY