www.siemens.com.

au/rail-components

Timer Style QTD4


Safety-Critical Slow-Release Timer (3 to 300 seconds)

All-In-One
The QTD4 timer is a safety-critical,
slow-release electronic timer that
directly drives an external slave
relay — all in a single plug-in Q relay
enclosure.

Safety Assured
Even under external or internal
component failure, the QTD4 never
extends the delay by more than 20% of
the set time.

Wide Range, Easy and


Accurate
Choose from 3 to 300 seconds in 4
ranges by using straps on the rear of the
plugboard. Then, for greater precision,
use the multi-turn potentiometer on the
Benefits front cover.
Ideal for safety-critical applications — release time cannot
extend by more than 20% SAFETY The safety-critical specification of this
product is not assured unless it is applied in
Slave relay powered from the QTD4 — no separate supply accordance with all the requirements of this
datasheet and maintained by Siemens.
needed WARNING

Datasheet 3J-2
Datasheet 3J-2 issue 6.0

Description Specifications
The QTD4 is a safety-critical slow-release Piece number M25159
electronic timer designed to provide a Power Operating voltage 12 V (±20%) dc or full-wave-rectified
delay between the opening of a control Operating current
0.5 A
contact and the subsequent release of a
normally-energised slave relay, with the Change of time 3–100 s ranges –10% for 20°C change
with temperature 100–300 s range ±15% typical
assurance that any failure will never (+15% to –40% worst case) for 20°C change
increase the delay by more than 20% of Change of time zero for 20% rise, –15% for 20% reduction
the set time. with voltage
Environmental Temperature 0 to 60°C
The QTD4 is operated from a 12 V dc or Humidity 0 to 95% non-condensing
full-wave-rectified supply. Plugboard Piece number M22312, code holes BCEGX
Internal Slave Supply Terminals and strappings
Supply + R1 – R2
The slave relay may be 12, 24 or 50 V dc
and is fed from the QTD4 — therefore no Slave relay coil + R3 – R4

separate supply is needed. Control contact D3–D4 (opening initiates timing)


Slave relay back contact D5–D6
Timing Adjustment Slave relay 12 V D2–D1
voltage strapping 24 V D2–D7
Timing ranges set by strappings: 50 V D2–D8
• 3–10 seconds Timing range 3–10 s none
• 11–30 seconds strapping 11–30 s A1–A7
• 31–100 seconds 31–100 s A1–A2–A7
101–300 s A1–A2–A3–
• 101–300 seconds A7

Adjustment within each range is by a


SAFETY Electrical Leakage between the Electrical Leakage to terminal A7
SAFETY
multi-turn potentiometer accessible control contacts connected to D3 and could lengthen or inhibit the time
through a screwed plug in the cover. The D4 and to the reset contacts delay.
connected between D5 and D6 can The strappings between A7 and A1,
plug has provision for sealing. WARNING
lengthen or inhibit the time delay.
WARNING
A2 or A3 should be a direct
SAFETY Always re-adjust the potentiometer External circuits must: connection using approved
for the required time whenever the •only use approved signalling signalling cable and be as short as
timer is replaced. cable; practical, unless you have assessed
WARNING •only use approved signalling the risk of any alternative to be
relays; acceptable.
•not have a total cable length of
Ordering greater than 1 metre and be as
short as possible;
• QTD4 slow-release timer: •not be installed where this circuit
part number M25159 can become damp or
contaminated.
• QTD4 plugboard:
Slave relay voltage
part number M22312 strappings:
D2–D1 12 V
A B C D D2–D7 24 V
D2–D8 50 V
Timing range 1 1
strappings:
3–10 s none 2 2
11–30 s A1–A7
31–100 s A1–A2–A7 3 3
101–300 s A1–A2–A3–A7 Control contact
4 4
5 QTD4 5
6 6
7 7
8 8
+ R1 R2 –

12 V dc + R3 R4 –
supply
Slave
relay

Wiring Diagram

Siemens Rail Automation Pty Ltd


ABN 78 800 102 483
Level 7, 380 Docklands Drive, Docklands,
Victoria 3008, Australia
T +61 1300 724 518
E [email protected]
W www.siemens.com.au/rail-components
© 2014, Siemens Rail Automation Pty Ltd