ST Geomative Co.

, Ltd
www.geomative.com
2019.3
Our products
GD series D.C. geo-electrical system is a world-leading multi-functional direct current (D.C.) method instrument, based on the latest digital and analog
circuitry technology. GD series comprises of GD-10 single-channel system and GD-20 multi-channel system. This series is capable of performing electrical
resistivity tomography (ERT), self-potential (SP) and induced polarization (IP) measurements. Apart from conventional electrical soundings, our products also
support cross-sectional profiling with 2D or 3D ERT arrays. GD series is not only supports conventional ground surveys, but also the geo-electrical
measurements in borehole logging, coal mining tunnels, marine and submarine surveys. This series is even equipped with online real-time field monitoring
mode, enabling our clients to perform unattended and automated surveys remotely for long durations.

Geomative has absorbed the advantages from both conventional centralized cabling system and distributed cabling system. We corporated the low-cost and
high reliability of the former along with the high efficiency and infinitely extensible cable sections of the latter system. A segment-centralized distributed wiring
mode was hence innovated by Geomative, acquiring both the rapidness of distributed cabling and the reliability of centralized cabling.

Major applications
l Groundwater and mineral exploration
l Underground contamination detection
l Urban engineering exploration
l Cavity exploration, Bedrock detection for pile foundation
l Seawater intrusion detection
l Dam seepage and leakage detection
l Geological mapping
l Archeological studies
l Real-time monitoring of landslides, tailings dams
l Sediment detection of river, lake and reservoir
l Borehole / Cross-hole invesigation

ST Geomative Co., Ltd


www.geomative.com
Technical Sepcification
Transmitting • SP compensation: Automatic linear drift correction
• Max transmitting power: 7200W/ 3200W/ 1600W • Automatic Ranging: Microprocessor controlled
• Max transmitting voltage: 800V for imaging, 1200V for VES.
• Max transmitting current: 6A for VES, 4A/2A for imaging General
• Current resolution: 1μA • Measurement variables :Apparent Resistivity , current, voltage, self -
• Current accuracy: 0.3% potential , IP
• Output wave: square wave(Res: 0+0-; IP: +0-0)
• Measurement method : Roll along facility, move sequence , disorder
• Resistivity cycle time: 0.8s by fault ,auto
• Power source : 16.8 V Internal re-chargeable battery or 24 ~60v
• IP cycle time :1, 2, 4, 8, 16, 32, 64s
external battery
• Input overvoltage protection : Up-to 1200V
• Data transfer: USB port for data transfer
• Input impedance: ≥200MΩ
SR-10 switch relay
Receiving •Length: 215mm
• Channel : 1 •Diameter: 50mm
• Input voltage range: ±24V •Weight: 0.4 kg
• Power interference: ≥120dB •Protection: IP67
• Voltage accuracy: 0.3% ±1 microvolts
Multi-electrode cable
• Resistivity accuracy: 0.3%
•Max voltage:800V
• AD resolution: 24 bit
•Max current: 2A for single-takeout and 4A for dual-takeout
• Full wave form: Yes •Cable insulation: 1000V/1G
• IP window: Time domain chargeability(M) M0-M19 •Take-outs: 5 dual-takeout; 10 single-takeout
• Manual iteration : 1~255 times •Spacing: 5m, 10m or customized (extrally set aside 10% for each
• Automatic iteration: 1~10 times • cable, 5.5m and 11m )

ST Geomative Co., Ltd


www.geomative.com
Model No. Basic Senior Advanced Supreme Supreme+ 2D+/3D+
1200V*6A 1200V*6A 800V*2A 800V*2A 800V*4A
SP √ √ √ √ √
1D Res VES √ √ √ √ √

1D IP VES √ √ √ √
2D Res Imaging √ √ √
2D IP Imaging √

3D Res Imaging √ √
3D IP Imaging √
Centralized System / / √ / /
Distributed System / / / √ √
Channel 1 1 1 1 1

Max Electrodes 4 4 60/120 Unlimited Unlimited

Online Upgrade √ √ √ √

ST Geomative Co., Ltd


www.geomative.com
System Configuration
L type cable:
* To connect the GD-10 mainframe and multi-electrode cable;

Connecting with multi-electrode cable * Two multi-electrode sockets for two directions; Low side is female
connector and high side is male connector;
* Two banana clips for A,B interfaces (Red for A, Black for B) as a
Low protection for high current.

Connecting with SR-10 switch relay

High

A,B
Connecting with the interface of
GD-10 "ERT Test Console" on the right
panel of GD-10 mainframe

Connecting with the interfaces of "A","B"


on the right panel of GD-10 mainframe

ST Geomative Co., Ltd


www.geomative.com
SR-10 Intelligent Dual-direction Switch Relay:
l To switch circuit and command
l To put the frontpart “Head” of SR-10 with multi-electrode cable towards GD-10 mainframe.
Head End l Made of PC material.
l Non-maintenance; No power required
l Excellent Insulativity
l Waterproof Raiting: IP67

u Segment-centralized Distributed Layout


End Head Head End Head End

1 2 3

1 2 3........................................................................................................7 8 9....................................

ST Geomative Co., Ltd


www.geomative.com
- Advanced CS-60 : Centralized Switch Box
l To switch circuit and command
l To connect with the GD-10 Advanced mainframe
l One set of CS-60 controls 60 electrodes at the most. A cable has 15 single-takeouts.
l Non-maintenance; No power required
l Excellent Insulativity
l Waterproof Raiting: IP67

u Centralized Layout

CS-60 switch box GD-10 Advanced mainframe CS-60 switch box

Multi-electrode cable: CB15

ST Geomative Co., Ltd


www.geomative.com
- Supreme 2D/3D, Supreme 2D+/3D+
BP-145
DC Rechargeable Power Source
(48v, 96v, 144v )

CE5 CB10

P1 P1
on
P2 ly
GD-10 Mainframe
Model No.: Basic, Senior, Advanced 2D, Supreme
2D/3D, Supreme 2D+/3D+
L type cable SR-10 switch relay Multi-electrode cable

ST Geomative Co., Ltd


www.geomative.com
Content I. 1D Vertical Electrical Sounding:
Function 1.1 1D Resistivity Sounding

I. 1V VES Sounding
1.1 1D Resistivity Sounding
1.2 1D IP Sounding
GD-10 mainframe BP-145 power source

II. Connection of 2D Imaging


2.1 Conventional Res Mode
2.2 Double Res Mode
2.3 Conventional IP Mode
2.4 Double IP Mode
2.5 2D Rolling along survey

III. Connection of 3D Imaging

Stailess steel electrode

BP-145 power source is optional.

ST Geomative Co., Ltd


www.geomative.com
Content I. 1D Vertical Electrical Sounding:
Function 1.2 1D IP Sounding
I. 1V VES Sounding
1.1 1D Resistivity Sounding
1.2 1D IP Sounding
GD-10 mainframe BP-145 power source

II. Connection of 2D Imaging


2.1 Conventional Res Mode
2.2 Double Res Mode
2.3 Conventional IP Mode
2.4 Double IP Mode
2.5 2D Rolling along survey

III. Connection of 3D Imaging

Solid non-polarization
Stailess steel electrode
electrode

BP-145 power source is optional.

ST Geomative Co., Ltd


www.geomative.com
Content II. Connection of 2D Imaging:

Function 2.1 2D Resistivity Imaging - Conventional Res Mode

I. 1V VES Sounding 2.1.1 GD-10 Series Single-takeout Bidirectional Connection


1.1 1D Resistivity Sounding +/- power
1.2 1D IP Sounding uMainframe is put in the middle of the survey line
uOnly P1 for staniless steel electrode.
II. Connection of 2D Imaging
2.1 Conventional Res Mode
2.2 Double Res Mode Connect with Multi- Banana clip for A,B
electrode socket interface
2.3 Conventional IP Mode
2.4 Double IP Mode
2.5 2D Rolling along survey
u Segment-centralized Distributed Layout
III. Connection of 3D Imaging SR-10
Multi-electrode Cable: CB5 switch relay
GD-10 BP-145
mainframe power source

SR-10
switch relay
SR-10
P1. P1. P1. P1.
switch relay
End Head Head End Head End
L type
1 2 3 ...............................................................13
cable 14 15 ........
ST Geomative Co., Ltd
www.geomative.com
Content II. Connection of 2D Imaging:
2.1 2D Resistivity Imaging - Conventional Res Mode
Function
2.1.2 GD-10 Series Single-takeout unidirectional Connection
I. 1V VES Sounding
1.1 1D Resistivity Sounding +/- power
1.2 1D IP Sounding uThe Mainframe is put only on one side of the survey line
uOnly P1 for staniless steel electrode.
II. Connection of 2D Imaging
2.1 2.2 Double Res Mode
2.3 Conventional IP Mode Banana clip for A,B
Connect with Multi-
2.4 Double IP Mode electrode socket interface

2.5 2D Rolling along survey

III. Connection of 3D Imaging


u Segment-centralized Distributed Layout
SR-10
switch relay
GD-10 BP-145
mainframe power source Multi-electrode Cable: CB10

SR-10
switch relay

End Head Head End

P1. P1. P1. P1.


L type cable

1 2 3 ...............................................................13 14 15 ........
ST Geomative Co., Ltd
www.geomative.com
Content II. Connection of 2D Imaging:
Function 2.2 2D Resistivity Imaging - Double Res Mode (Double Current)

I. 1V VES Sounding
1.1 1D Resistivity Sounding
1.2 1D IP Sounding

II. Connection of 2D Imaging


2.1 Conventional Res Mode
2.2 Double Res Mode
2.3 Conventional IP Mode
2.4 Double IP Mode
2.5 2D Rolling along survey

III. Connection of 3D Imaging


Note:

1. BP-145 is optional item, not in the standard configuration;


2. P1 and P2 is relative concept, indicating single and double takeout
3. Double Res mode needs to connect electrode with both P1 and P2.
4. Max current 4A;
5. The end of the survey line must connect one SR-10 cable leader for winding up.

ST Geomative Co., Ltd


www.geomative.com
Content II. Connection of 2D Imaging:
System Configuration
2.3 2D IP Imaging - Conventional IP Mode
2.3.1 GD-10 Series dual-takeout Unidirectional Connection
I. 1V VES Sounding
u P1 for stainless steel electrode;
1.1 1D Resistivity Sounding
1.2 1D IP Sounding u P2 for solid non-polarization electrode .

II. Connection of 2D Imaging


GD-10 mainframe
2.1 Conventional Res Mode BP-145 power source

2.2 Double Res Mode


2.3 Conventional IP Mode
Multi-electrode Cable: CB5
2.4 Double IP Mode
2.5 2D Rolling along survey
P1..P2 P1..P2 P1..P2 P1..P2 SR-10 switch relay
III. Connection of 3D Imaging
Head End
Head End

Stailess steel electrode Solid non-polarization electrode L type cable

ST Geomative Co., Ltd


www.geomative.com
Content II. Connection of 2D Imaging:
System Configuration
2.3 2D IP Imaging - Conventional IP Mode
2.3.2 GD-10 Series dual-takeout Bidirectional Connection
I. 1V VES Sounding
u P1 for stainless steel electrode;
1.1 1D Resistivity Sounding
1.2 1D IP Sounding u P2 for solid non-polarization electrode .

II. Connection of 2D Imaging


2.1 Conventional Res Mode
2.2 Double Res Mode GD-10 mainframe
2.3 Conventional IP Mode
2.4 Double IP Mode
2.5 2D Rolling along survey P1..P2 P1..P2 P1..P2 P1..P2

SR-10 switch relay


SR-10 switch relay
III. Connection of 3D Imaging

Head End
L type cable

Stailess steel electrode Solid non-polarization electrode

ST Geomative Co., Ltd


www.geomative.com
Content II. Connection of 2D Imaging:

System Configuration 2.4 2D IP Imaging - Double IP Mode


I. 1V VES Sounding
1.1 1D Resistivity Sounding
1.2 1D IP Sounding

II. Connection of 2D Imaging


2.1 Conventional Res Mode
2.2 Double Res Mode
2.3 Conventional IP Mode
2.4 Double IP Mode
2.5 2D Rolling along survey

Note:
III. Connection of 3D Imaging
1. BP-145 is optional item, not in the standard configuration;
2. P1 and P2 is relative concept;
3. Two survey lines layout in parallel,and connected with the two multi-electrode
cable sockets on L type cable;
4. The cable in low side takes the connection method of double Res mode, the cables in
high side only connect the solid non-polarization electrode with P2 as receiving.
5. Max current 4A;
6. The end of the survey line must connect one SR-10 cable leader for winding up.

ST Geomative Co., Ltd


www.geomative.com
Content II. Connection of 2D Imaging:

System Configuration 2.5 2D Rolling along survey


I. 1V VES Sounding 2.5.1. GD-10 mainframe is put only on one side of survey line
1.1 1D Resistivity Sounding
1.2 1D IP Sounding u Please choose 1 cable or 2 cable rolling when setting
new 2D task on mainframe.
II. Connection of 2D Imaging
2.1 Conventional Res Mode
2.2 Double Res Mode
2.3 Conventional IP Mode
2.4 Double IP Mode
2.5 2D Rolling along survey

III. Connection of 3D Imaging

* Only take one multi-electrode cable socket (High) in L type cable.

* For each rolling along survey, the first or first two cables need to be moved to the end of the section, and the
GD-10 mainframe also move forward to the start of the section.

* Max two cables can take rolling along survey.

* At each rolling, please turn off mainframe, and then move the mainframe and cables. ST Geomative Co., Ltd
www.geomative.com
Content 2.5.2.GD-10 Mainframe is put in the middle of the survey line

System Configuration
u Please choose 1 cable or 2 cable rolling when setting
I. 1V VES Sounding new 2D task on mainframe.
1.1 1D Resistivity Sounding
1.2 1D IP Sounding

II. Connection of 2D Imaging


2.1 Conventional Res Mode
2.2 Double Res Mode
2.3 Conventional IP Mode
2.4 Double IP Mode
2.5 2D Rolling along survey

III. Connection of 3D Imaging

* Take two multi-electrode cable sockets in L type cable.

* For each rolling along survey, the first or first two cables need to be moved to the end of the section.

* Max two cables can take rolling along survey.

* At each rolling, please turn off mainframe, and then move the mainframe and cables.
ST Geomative Co., Ltd
www.geomative.com
Content III. Connection of 3D Imaging:

System Configuration 3D Res Imaging 3D IP Imaging

I. 1V VES Sounding
1.1 1D Resistivity Sounding GD-10 mainframe BP-145 power source
1.2 1D IP Sounding

II. Connection of 2D Imaging


2.1 Conventional Res Mode
2.2 Double Res Mode
2.3 Conventional IP Mode
2.4 Double IP Mode L type cable SR-10 switch relay Stailess steel Solid non-polarization
electrode electrode
2.5 2D Rolling along survey
Head End

III. Connection of 3D Imaging

Head
SR-10
switch SR-10 switch relay
End
relay

Head End

ST Geomative Co., Ltd


www.geomative.com
P20