TECHNOLOGY SOLUTION FOR


• Specific Absorption Rate (SAR) measurement • Mobile equipment device development
• Mobile equipment device testing
• Mobile equipment device certification
• Any equipment radiating close to the body
MVG provides a complete line of SAR equipment to ensure compliancy with certification
standards as well as flexibility in terms of set-up and use. The COMOSAR systems are available in four
configurations: with one, two, three or four phantom tables. The COMOSAR standard benches are
complete turn-key systems which include a set of equipment and accessories to cover all
customer requirements.

Main features
Measurement capabilities Frequency bands
• Head and Body SAR Measurement • 30 MHz to 6 GHz
• Enhanced HAC Testing capabilities available
with additional COMOHAC kit

System configurations
Laptop positioning system
Software

 Base station positioning system


■ OPENSAR V5 (Under License) NEW  Dipole for additional frequencies

 Head and body liquids for additional frequencies


Equipment
Add on
■ SAM phantom
■ Probe holder with security sensor  Liquid measurement kit (LIMESAR)
■ Video positioning system  SAR/HAC Probe calibration kit (CALIProbe) NEW

■ Handset positioning system  HAC evaluation kit (COMOHAC)


■ Multimeter with scan card
 A broad selection of phantoms*
Document
 Vector Network Analyzer (for liquid characterization) ■ Acceptance report
 Network Simulator (to emulate Device Under Test) ■ Calibration reports
 Signal Generator (for system validation) ■ Cumulated uncertainty reports
■ User manual
Accessories
Services
■ GPIB card
■ GPIB cable ■ SAR Probe calibration 900, 1800 MHz
■ GSM 900 head liquid (30 liters) ■ Installation
■ GSM 1800 head liquid (30 liters) ■ Training
■ IEEE GSM 900 dipole ■ 1 year warranty
■ IEEE GSM 1800 dipole  Probe calibration for additional frequencies
■ GSM 835/900/1800/1900/2000 test antenna  Extended warranty
■ Probe shielded cable
■ 3 GHz E-field probe
 6 GHz E-field probe
* See a complete list of available SAM and flat phantoms in our SAR
 Validation dipoles
& HAC catalog.

 Included  Optional  Required


System overview

Ethernet
OPENSAR Vector
software network
analyzer

Signal
Robot generator
GPIB, Ethernet, RS 232

Network Voltmeter Power meter


emulator

Compliancy Fexible set-up


COMOSAR bench has been developed to perform Set-up could be long, and is often the most time-
SAR measurements for the certification of device in full consuming phase of the measurement; this is particular-
compliancy with the international standards. ly true during R&D tests. In order to optimize the time of
the overall measurement process, we offer full turn-key
It is available with a range of additional equipment and systems in four configurations: with 1, 2, 3 or 4 tables.
accessories to cover all needs with regard to these
standards. Our tables are compatible with any of our phantoms or kits
(HAC or CALIProbe) and have been designed to stabilize
mechanical performance over a long time period.

Our OPENSAR software already integrates drivers for the


most commonly used RF equipment:

List of available drivers*


Network Simulator Signal Generator Power Meter Vector Network Analyzer
Rohde &Schwarz CMU 200 (1)
Rohde &Schwarz SMB, SML, SMT, Rohde &Schwarz Rohde & Schwarz
Rohde &Schwarz CMW 500(1) SMIQ, SMP, SMR27, CMU 200 NRVD, NRVS, NRP-Z21 ZVA, ZVB, ZVL, ZVR
Anritsu MT8820 Agilent E8257C, ESG serie Agilent E4416A, N191x Anritsu MS4622B
Agilent HP8753C, HP8753D,
Agilent 5515C AnaPico APSIN6010 Anritsu ML2430, MA 24106 A
HP8753E, E5071B
Agilent 8357, 8510C, HP8753C/E,
Willtek 4200, 4400, 3100 Keithley 3500
HP8753D, E5071B, N9923
Wavetek 3107S National Instrument USB5680
* Additional drivers can be added upon request.
(1) including audio capabilities
Reduce measurement time LIMESAR is directly operated from our OPENSAR SW
allowing easier routine management. It can be also install
on a separate computer in a liquid dedicated lab.
MVG has implemented several SW features to enhance the
measurement speed:
• Controlling
 the radio tester allows the measurement of
the 3 channels simultaneously through inter-channel  educe measurement
R
handover (20% of measurement reducing).
• Adaptive
 path algorithm reduces the number of points
uncertainties
measured during the area scan (divide measurement
time up to 5). All components of the COMOSAR System have been
• 3D
 truncation algorithm quickens the zoom scan process designed to facilitate the exact positioning of probes,
(divide measurement up to 5). phantoms and Devices Under Test (DUT):
•A  Video Positioning System (VPS) ensures the probes’
As a result, the combination of these algorithms brings position at ± 0.1mm. VPS is fixed on the table plate and
measurement time for one channel down to 1 minute and calibrated during the installation.
for 3 channels down to 2 minutes for one handset in a • The
 handset positioning system includes two rails with a
given position. precision < 1°.
• Moving
 from the tilt to the cheek position is possible in 1
slide.
• The
 probes are made of high permittivity material to
LIMESAR: an efficient solution minimize E-field disturbance. Hence, it is possible to
to assess liquids properties perform measurements without any amplification or
embedded battery.
LIMESAR is a liquid measurement add-on. It enables the li-
quid properties to be checked and potential deviation over
time to be consider for SAR calculations.

COMOSAR
Mechanical

Product specifications and descriptions in this document are subject to change without notice. Actual products may differ in appearance from images shown.
SINGLE TWIN TRIO QUAD
Dimensions (L, W, H) 1.00 x 0.62 x 2.00 m 1.00 x 1.44 x 2.00 m 2.74 x 2.74 x 2.00 m 2.74 x 2.74 x 2.00 m
Estimated room size* 3.00 x 3.00 x 2.50 m 3.00 x 3.00 x 2.50 m 4.00 x 4.00 x 3.00 m 4.00 x 4.00 x 3.00 m
* RF instrumentation not included in the estimate

© MVG 2018 - DT.119.1.16.MVI.B - Graphic design: www.ateliermaupoux.com, pictures: all rights reserved.

Video positioning system COMOSAR Twin configuration

Contact your local sales representative for more information


www.mvg-world.com
Indonesia distributor :
PT. Unitronic Jaya ; +62-22-7538688 ; [email protected] ;
www.unitronicjaya.com

You might also like