Inner Hull installation for Echo Sounder’s transducer

The temporary modification when damaged transducer of the Echo


Sounder.

TRANSDUCER
1. The installation method of transducer to the ship's bottom.
2. For safety;
Open the manhole on before 24-hour work start, and remove the
poisonous gas.
3. Clean the water and oil at transducer area.
4. New transducer is installed on the flat bottom of inside the same area
with the silicone rubber.
5. Silicone rubber is applied in the thickness of about 2mm to 3mm, and
a air bubble is made not to come in.
6. Transducer is fixed, an old transducer cable is cut and connected with
the new transducer cable.
7. After above transducer cable connection, and taping for the
waterproof.

CLEAN AREA

TRANSDUCER NEW TRANSDUCER


SILICON RUBBER
ORIGINAL POSITION

65
ECHO SOUNDER FITTING ON INNER HULL.

This photograph for JFE-582 (200kHz)

Photograph 1
The digital display is none only in the time mark and the oscillation line recording on paper.

Photograph 2
Transducer tank

66
Check the following item of the old cable before connect it.
*Insulation resistance .
*The breakage of the cable .

Photograph 3 Old Transducer cable


Transducer cable connection part Waterproof processing execution ending

Photograph 4
Position where Transducer is installed inner Hull

67
Photograph 5
Silicon rubber was spread from 2 to 3mm on the hull bottom of a ship and the transducer side,
and this silicon rubber fixed surroundings.

Confirmation
Check it after about 24 hours after the above working end.
Silicone rubber is necessary to fix for 24 hours.

Material to prepare

ITEM TYPE JRC CODE


Transducer for JFE-582 UT-200ND20 (200kHz) 6UNBS00285
JFE-585 UT-50MD-20 (50kHz) 5UNAB00025
--------------------------------------------------------------------------------------------------------
Silicone rubber ex.KE-45-W SHINETSU 1162010009 @100g 3pcs
Rubber tape BRXP00469 one roll
Plastic tape one roll
Or equivalent