Modbus connection document description

Modbus connection document description

Hangzhou Huasu Technology Co., Ltd


2nd& 3rd Floor of No. 3 Building, No. 1418-50 Moganshan Road, Hangzhou, China
TEL: 0086-571-87967915 FAX:0086-571-87968969
http://huasu-tech.com//

HTTP://HUASU-TECH.COM// TEL:0571-87967915
Modbus connection document description

LAN connection between CM module and computer


The network cable is directly connected to the CM module and the computer

CM module:D.setup – PIN 2022 – 3.setup – 3.2GL Set -

IP :192.168.0.105

subnet :255.255.255.0

gateway:192.168.0.1

Port : 4002

PC TCP IPV4
IP :192.168.0.101(Consistent with CM module gateway)
subnet :255.255.255.0

HTTP://HUASU-TECH.COM// TEL:0571-87967915
Modbus connection document description

If connected through a network switch

Cm module:D.setup – PIN 2022 – 3.setup – 3.2GL Set -


#1 CM IP :192.168.0.105
subnet :255.255.255.0
gateway:192.168.0.1
Port : 4002
Multiple CM modules, IP cannot be repeated
#2 CM IP :192.168.0.106
subnet :255.255.255.0
gateway:192.168.0.1
Port : 4002

PC TCP IPV4
IP :192.168.0.107(IP cannot be repeated with CM module)
subnet :255.255.255.0
gateway:192.168.0.1

HTTP://HUASU-TECH.COM// TEL:0571-87967915
Modbus connection document description

Modbus poll
IP:192.168.0.105(Different IP addresses need to be entered for different CM modules)
Port:4002
If the CM module changes the IP, subnet and gateway, restart the CM module (power off /
on) after the change

Check read / write disabled

Device ID : 17
Cm module address: 1 ,
CM module address: D.setup – PIN 2022 – 3.setup – 3.2GL Set –

first battery string : 1


HEX:11, DEC: 17
Modbus poll slave ID : 17

If the CM module address is 2. first battery string: 1


HEX:21, DEC: 33
Modbus poll slave ID : 33

HTTP://HUASU-TECH.COM// TEL:0571-87967915
Modbus connection document description

Confirm cm module communication protocol


CM module communication protocol: D.setup – PIN 2022 – 3.setup – 3.2GL Set –

Modbus 600 communication protocol:Normal

The following model is the 600 protocol


Modbus Point Type : 03 : HOLDING REGISTER
Address:10001

The voltage of the first battery is 12.686V

HTTP://HUASU-TECH.COM// TEL:0571-87967915
Modbus connection document description

Use 485 connection


USB : TR+ connect COM5 5+
USB : TR- connect COM5 9-

CM module Baud rate:19200 , The communication protocol is modbus600

HTTP://HUASU-TECH.COM// TEL:0571-87967915
Modbus connection document description

ON PC: Determine whether the USB COM port is correct

Baud rate:19200
(TA module, TC module 9600, CM module 19200)
Data bits: 8
Parity: none
Stop: 1

Device ID : 17
Cm module address: 1 . first battery string : 1
HEX:11, DEC: 17
Modbus poll slave ID : 17
CM module address: D.setup – PIN 2022 – 3.setup – 3.2GL Set –

If the CM module address is 2. first battery: 1


HEX:21, DEC: 33
Modbus poll slave ID : 33
Multiple CM modules need to set different CM module addresses
Check read / write disabled

HTTP://HUASU-TECH.COM// TEL:0571-87967915
Modbus connection document description

The following model is the 600 protocol


Modbus Point Type : 03 : HOLDING REGISTER
Address:10001

The voltage of the String1 first battery is 12.686V

HTTP://HUASU-TECH.COM// TEL:0571-87967915