C20-D6
C20-D6
C20-D6
Diesel
generator set
X2.5 series
engine
15 kVA–27 kVA 50 Hz
10.8 kW–20 kW 60 Hz
Description
This Cummins® Power Generation Cooling system – Standard integral set-
commercial generator set is a fully integrated mounted radiator system, designed and tested
power generation system, providing optimum for rated ambient temperatures, simplifies facility
performance, reliability, and versatility design requirements for rejected heat.
for stationary standby, prime power, and
continuous duty applications. Control system – PowerStart control,
microprocessor-based generator set monitoring
and control system provides a simple operator
Features interface to the generator set, manual and
Cummins® heavy-duty engine – Rugged remote start/stop control and shutdown fault
4-cycle industrial diesel delivers reliable indication.
power, low emissions and fast response to
load changes. Enclosures – Optional weather-protective and
sound-attenuated enclosure.
Optional excitation boost system
(EBS) – Offers enhanced motor starting and Warranty – Backed by a comprehensive
fault clearing short circuit capability. warranty and Worldwide distributor network.
Engine specifications
Design 4 cycle, in-line, naturally aspirated
Bore 91.7 mm
Stroke 127 mm
Displacement 2.5 liter (153 in3)
Cylinder block Alloy cast iron, in-line, 3 cylinder
Battery charging alternator 36 A
Starting voltage 12 volt, negative ground
Fuel system Direct injection
Fuel filter Spin on fuel filters with water separator
Air cleaner type Dry replaceable element
Lube oil filter type(s) Spin on full flow filter, filtration efficiency 25 micron 99% (min)
Standard cooling system 122 °F (50 °C) ambient radiator with coolant recovery system
Alternator specifications
Design Brushless, single bearing
Stator 2/3 pitch
Insulation system Class H
Standard temperature rise 125–163 °C
Exciter type Self excited
Phase rotation A (U), B (V), C (W)
Alternator cooling Direct drive centrifugal blower fan
AC waveform total harmonic distortion (THDV) No load to full linear load < 5%. For any single harmonic < 3%
Telephone influence factor (TIF) < 50 per NEMA MG1-22.43
Telephone harmonic factor (THF) < 3%
Available voltages
50 Hz Line–Line/Line–Neutral 60 Hz Line–Line/Line–Neutral
3-Phase 1 Phase 3-Phase 1 Phase
• 240/416 • 127/220 • 220 • 277/480 • 127/220 • 220
• 255/480 • 120/208 • 230 • 240/416 • 120/208 • 230
• 230/400 • 115/200 • 240 • 255/440 • 240
• 220/380 • 110/190
Note: Consult factory for other voltages.
C
load for the duration of power interruption of a reliable
utility source. Emergency standby power (ESP) is
in accordance with ISO 8528. Fuel stop power in
accordance with ISO 3046, AS 2789, DIN 6271 and A B
BS 5514.
C
Prime power (PRP):
Applicable for supplying power to varying electrical
load for unlimited hours. Prime power (PRP) is in
A B
accordance with ISO 8528. Ten percent overload
capability is available in accordance with ISO 3046,
AS 2789, DIN 6271 and BS 5514. This outline drawing is to provide representative configuration
details for Model series only.
Base load (continuous) power (COP):
See respective model data sheet for specific model outline
Applicable for supplying power continuously to
drawing number.
a constant electrical load for unlimited hours.
Continuous power (COP) in accordance with
ISO 8528, ISO 3046, AS 2789, DIN 6271 and BS 5514. Do not use for installation design
Certifications
This generator set is designed in facilities
This generator set is available with
certified to ISO 9001 and manufactured in
CE certification.
facilities certified to ISO 9001 or ISO 9002.