Technical Specification of Vortex Flowmeter
Technical Specification of Vortex Flowmeter
1.Tehcical data:
liquid gas
Size
Standard Extended (20℃,101325Pa)
The sensor should be installed on a pipeline with the same diameter as the
horizontal, vertical, and inclined (liquid flow from bottom to top) pipeline.
sensor. Upstream and downstream of the pipeline should be equipped with a
certain length of straight pipe section, which should conform to the length of
the front straight pipe section 15-20D and the rear straight pipe section 5-10D
The requirements.
The pipeline near the installation of the liquid sensor should be filled with the
measured liquid. Sensors should be avoided from being installed in pipes with
strong mechanical vibrations on the road.
The inner diameter of the straight pipe section should be as consistent as
possible with the sensor diameter. If it cannot be consistent, a pipe slightly
larger than the sensor diameter should be used, the error should be ≤ 3%
and not exceed 5mm.
When the measured medium contains a large amount of impurities, a filter
should be installed beyond the required length of the straight pipe section
upstream of the sensor.
Sensors should be avoided from being installed in places with strong
electromagnetic field interference, small space, and inconvenient
maintenance.