Prepared by: Nilesh Kanphade CM(IT)
NOTE: Please do the following setting before joining PC to Active directory.
Local Area Network IP address :
IP addresses of PCs should be configured as example explained below
Example:
Branch code: D0929
IP Addresses to be allocated to PCs: 10.9.29.02 TO 10.9.29.254
GATEWAY: 10.9.29.1
Network Name nomenclature for PCs:
Name of PCs is to be given as follows
Example: Branch Code: D0929
PC name: PSB-BRANCH CODE- PC(IP NO)
For example: PC name for Pc with IP address 10.9.29.2 is PSB-D0929-PC2
Java Installation (for Finacle application)
- Copy file .java.policy from CD and paste the same into all sub folders under C:\documents
& settings(i.e. C:\ documents & settings\ Administrator , C:\documents & Settings\All users ,
C:\documents & Settings\Acer(Wipro) etc.)
- Double Click on file jre-6420-windows-i586-s > Click on Install > Click on Close after
installation completed.
- Double Click on File MSJavWU (Please ignore the error message )>ok.
- Double Click on File MSJavWU_8073687b82d41db (Ignore the error message)>ok.
ILINKWEB installation:
- Double Click on ILINKWEB folder > Double Click on INSTALL (exe) > It show following
message(black screen)
----------------------------------------------------------------------------------------------------------
|
| Copyright (C) 2002,Integra Micro Systems (P) Ltd., Bangalore - India 560001.
|
| Installing : ##################
|
|
| iLINK/WEB is installed successfully , Press Enter To Exit .....
Page 9 of 18
|
-Press enter and restart the computer.
Please ensure that ILINKWEB window (In Black Screen)show following options:
Version : ilinkweb 1.4
Language : English
Host name : 10.xx.xx.xx (IP Address of PC)
Listening on port : 9999
Note:This window(ilinkweb) should be ON/Minimize on PC during working hours for printing.
For report finacle report generation please create following two folders at C: drive
- (1) finaclereports
- (2) finaclermi
Biometric Setup
Install biometric morpho device drivers. These drivers are available on intranet portal
https://intranet.psb.co.in/Download/CPPC/32bit-Morpho-MSO13XX.zip
https://intranet.psb.co.in/Download/CPPC/64bit-Morpho-MSO13XX.zip
For EKYC install morpho RD service setup
https://intranet.psb.co.in/Download/utility/morpho.zip
For more troubleshooting of EKYC setup please refer intranet site.
https://intranet.psb.co.in/Download/utility/Troubleshooting%20Steps.zip
https://intranet.psb.co.in/Download/Ekyc/2020/EKYC%20Troubleshooting.zip
SIGNCAP Installation for signature scanning.
- Double Click on signcap folder> Double Click on SignCap 6.1.2 - General Version
folder> Double Click on SETUP and wait till installation completed.
Page 10 of 18
Please open internet option setting
Page 11 of 18
Open security tab after that click on Local Intranet- then click on sites
Page 12 of 18
After That click on advanced
Page 13 of 18
After clicking advance following scree appears the add psb.co.in and psb.org.in.
Then close the tabs the click ok
Page 14 of 18
Similarly please add following sites as trusted site
This setting must be done on every user of PC /AD.
Page 15 of 18
Proxy setting
Page 16 of 18
Configure the following Proxy setting
Page 17 of 18
Important URLs
http://psbmis.psb.org.in:8080/PSBMIS/PSBMIS.html
http://portal5.psb.org.in:8080/Login.html
https://intranet.psb.co.in
https://outlook.office365.com/mail/
For any clarification please mail to [email protected]
Page 18 of 18