Relogio LM8365
Relogio LM8365
Feature:
Designed as Model all parts on one PCB
Show times is AM and PM
Can set times alert 2 times in 24 hour
Can schedule appliance to 1 hour.
It has the backup battery when power outage this clock non stop.
Can show dates, months or seconds
– Pin 25 SNOOZE I/P is input of the SNOOZE pushbutton switch which is connect to
the positive voltage through switch to To stop the alarm, while about 9 minutes
– Pin 26_ALARM 1 O/P is pin output of the first alarm
– Pin 27_ALARM 1 OFF is pin connect to positive voltage to switch to stop the first
alarm
– Pin 28 _SLEEP O/P is output of setting the appliances for long 1 hour
– Pin 29_Alarm 2 OFF is pin to connect the positive voltage switch to stop the 2nd
alarm
– Pin 30_Vdd is Ground
– Pin 31_SLEEP DISPLAY I/P is pin positive to through switch to read times in setting
the appliances
– Pin 32 ALARM 1 DISPLAY I/P is pin connect the positive voltage to switch to read
times the first alarm
– Pin 33_SECOND DISPLAY I/P is pin connects the positive voltage through switch to
press to look time in seconds
– Pin 34_LOWER SET I/P is pin connects the positive voltage through the switch to
press to look time in minutes
– Pin 35_UPPER SET I/P is pin connects the positive voltage through the switch to
press to look time in hour
– Pin 36_50/60 Hz I/P is pin connect the time base 50/60Hz frequencies
– Pin 37_50/60Hz select is pin to connects selects the times bases frequency. If want 50
Hz to the positive and when you want 60Hz to ground
– Pin 38_ALARM 2 DISPLAY I/P is pin connects the positive voltage through the
switch to look the 2nd times setting
– Pin 39 24/12HR SELECT is pin to select display in 12 hour or 24 hour. If you leave
floats or to the ground is a 12 hour. and If connect to positive will be 24 hour.
– Pin 40 1Hz O/P is pin output to connect to LED display show flashing in second
– Pin 41 PM O/P is pin output to drive LED display at pot PM
– Pin 42_CR I/P is pin connect to the positive voltage through the switch to press clear
times setting
How it works
In circuit diagram as Figure 2 at pin 37, which is pin 50/60Hz, Selected to ground, show
that this times base is 60Hz.
The pin 33 floating, indicating that the circuit is not displays a value of seconds. It can
be used by itself to the positive voltage to switch through to look seconds.
Figure 2 The schematic diagram of this project.
D3 and D4 connects the output of alarm both 2 pin are pin 26 and pin 1. Connect driver
Buzzers.
The pin 28 is pin SLEEP O/P connects to D5 the relay driver, by have Q2,R3 and R4
are the relay driver circuit.
There are D6 block is the voltage that will happen, If the power feed to the relay will
stop the magnetic field collapses, cutting a relay coil voltage across the relay coil. This
voltage can damage other equipment in the circuit.
The terminal point the relay NO and NC must to connect to voltage 220VAC through
contact NO and COM, to control timer the appliances for 1 hour
IC2 number MM5369 is an IC Clock Generator 60HZ. Which is the times base of IC1,
the X-Tal 3.579 MHz is the frequency output 60Hz, connect to output pin 1 through R7
to pin 36 of IC1.
The Q3, R6 and the Zener diode ZD1 / 6V are connected the regulator circuit saving by
three parts, Makes it voltage of the regulator circuit to maintain a constant cycle of
approximately 5.4V.
It works as follows: R6 and ZD1 series causes a constant voltage of 6V the Zener diode.
This point is connected to pin B of Q3 makes the voltage at pin B is steady.
Generally, when we have to maintain the voltage at pin B. The voltage at pin E will be
steady, which led to the basic regulator circuit and saving.
But when transistor works, Q3 which is NPN type the voltage at pin B will be must
higher than pin E about 0.6V. Thus the voltage at regulator so have 5.4V. Which is
sufficient for the operation of the circuit R5 and D7 connected to backup battery circuit
is 4.8V.
When power voltage 4.8V from battery will feed to D7 in to circuit instead voltage from
the regulator circuit. But when the voltage remains normal, the voltage from the
regulator circuit will be higher than voltage from battery, stop flow into the voltage
circuit from the power supply will through R5 into charge battery instead.
Recommendations for the battery, should be the nickel cadmium battery in series 4 pcs.
Q4,R10,C6 and D11 connected to get the voltage from terminal transformer is bias to
transistor Q4 connect to common of LED display to ground through to R10. When
power outlet, Q4 will stop working , make pin COM of LED display unconnected to
ground of LED display to saving the power of backup battery.
How to builds
All components are installed on one PCB so easy to builds as Figure 4 and Figure 5
Then check the validity. It can be plugged into use immediately.
Caution: Need to put Q3-2SC1846 correctly
Figure 3 the PCB layout of LM8365
Figure 4 the components layout
Electrolytic Capacitors
C2, C6: 10uF 16V
C3: 1000uF 16V
Ceramic Capacitors
C1: 0.1uF 50V
C4: 10pF 50V
C5: 30pF 50V
Semiconductors
IC1: LM8365
IC2: MM5369
D1 – D5 and D12: 1N4148 Diode
D5 – D11: 1N4001 Diode
Q1, Q2 and Q4: BC547C
Q3: 2SC1846
ZD1: 6V 1A 0.5W Zener diode
Others
X1: X-Tal 3.579MHz
BZ1: 6V buzzer
RY1: 6V Relay
T1: 9V,200mA transformer
and more