LP140WH2 TLL2
LP140WH2 TLL2
SPECIFICATION
FOR
APPROVAL
( ) Preliminary Specification
( ◆ ) Final Specification
N. J. Seong / Manager
/
REVIEWED BY
/
S. S. Han / Engineer
/ PREPARED BY
C. H. Hwang / Engineer
S. K. Ahn / Engineer
Please return 1 copy for your confirmation with Products Engineering Dept.
your signature and comments. LG Display Co., Ltd
Contents
No ITEM Page
COVER 1
CONTENTS 2
RECORD OF REVISIONS 3
1 GENERAL DESCRIPTION 4
3 ELECTRICAL SPECIFICATIONS
6 RELIABLITY 20
7 INTERNATIONAL STANDARDS
7-1 SAFETY 21
7-2 EMC 21
7-3 Environment 21
8 PACKING
9 PRECAUTIONS 23-24
RECORD OF REVISIONS
EDID
Revision No Revision Date Page Description
ver
0.0 Apr. 09. 2010 - First Draft (Preliminary Specification) -
1.0 Jul. 16. 2010 - Final Specification -
4, 6 Update the Electrical Characteristics. (Power Consumption)
14 Update Color Coordinates
15 Update Gray Scale
1. General Description
The LP140WH2 is a Color Active Matrix Liquid Crystal Display with an integral LED backlight system. The
matrix employs a-Si Thin Film Transistor as the active element. It is a transmissive type display operating in
the normally white mode. This TFT-LCD has 14.0 inches diagonally measured active display area with HD
resolution (1366 horizontal by 768 vertical pixel array). Each pixel is divided into Red, Green and Blue sub-
pixels or dots which are arranged in vertical stripes. Gray scale or the brightness of the sub-pixel color is
determined with a 6-bit gray scale signal for each dot, thus, presenting a palette of more than 262,144
colors. The LP140WH2 has been designed to apply the interface method that enables low power, high
speed, low EMI. The LP140WH2 is intended to support applications where thin thickness, low power are
critical factors and graphic displays are important. In combination with the vertical arrangement of the sub-
pixels, the LP140WH2 characteristics provide an excellent flat display for office automation products such
as Notebook PC.
EEPROM
EEPROM Block
Block
for
forEDID
EDID
EEPROM
EEPROMBlock
Block 1 1366
for
forTcon
TconOperating
Operating
User connector
TFT-LCD Panel
LVDS Timing
TimingControl
Control (HD, GIP, TN)
1port (Tcon)
(Tcon)Block
Block
Min
i-LV 768
DVCC TCLKs DS
40
DVCC, AVDD
Pin
VOUT_LED
VLED LED LED Backlight Ass’y
LEDDriver
Driver FB1~4
LED_EN
PWM Block
Block
Values
Parameter Symbol Units Notes
Min Max
Power Input Voltage VCC -0.3 4.0 Vdc at 25 ± 5°C
Note : 1. Temperature and relative humidity range are shown in the figure below.
Wet bulb temperature should be 39°C Max, and no condensation of water.
90% 80%
60 60%
Wet Bulb 50
Humidity[(%)RH]
℃]
Temperature [℃ Storage
40 40%
30 Operation
20
20%
10
0
10%
-20 0 10 20 30 40 50 60 70 80
℃]
Dry Bulb Temperature [℃
3. Electrical Specifications
3-1. Electrical Characteristics
The LP140WH2 requires two power inputs. The first logic is employed to power the LCD electronics and to
drive the TFT array and liquid crystal. The second backlight is the input about LED BL with LED Driver.
Note)
1. The measuring position is the connector of LCM and the test conditions are under 25℃, fv = 60Hz,
Black pattern.
2. The specified Icc current and power consumption are under the Vcc = 3.3V , 25℃, fv = 60Hz condition.
Mosaic Pattern
3. This Spec. is the max load condition for the cable impedance designing.
4. The below figures are the measuring Vcc condition and the Vcc control block LGD used.
The Vcc condition is same as the minimum of T1 at Power on sequence.
3.3V
Rising time
Vcc 90%
0V 10%
0.5ms
5. This impedance value is needed for proper display and measured form LVDS Tx to the mating connector.
6. The measuring position is the connector of LCM and the test conditions are under 25℃.
7. The current and power consumption with LED Driver are under the Vled = 12.0V , 25℃, Dimming of
Max luminance and White pattern with the normal frame frequency operated(60Hz).
8. The below figures are the measuring Vled condition 12.0V
and the Vled control block LGD used. Rising time 90%
VLED control block is same with Vcc control block. VLED
0V 10%
0.5ms
9. The operation of LED Driver below minimum dimming ratio may cause flickering or reliability issue.
10. If Jitter of PWM is bigger than maximum, it may induce flickering.
11. This Spec. is not effective at 100% dimming ratio as an exception because it has DC level equivalent
to 0Hz. In spite of acceptable range as defined, the PWM Frequency should be fixed and stable for
more consistent brightness control at any specific level desired.
12. The life time is determined as the time at which brightness of LCD is 50% compare to that of minimum
value specified in table 7. under general user condition.
3-3-1. DC Specification
VDD=1.8V
3-3-2. AC Specification
Freq.
Fmax
Fcenter * FDEV
Fcenter
Fmin
1
FMOD
Time
RCLK+
RA+/- R3 R2 R1 R0 G0 R5 R4 R3 R2 R1 R0 G0 R5 R4
RB+/- G4 G3 G2 G1 B1 B0 G5 G4 G3 G2 G1 B1 B0 G5
RD+/- G7 G6 R7 R6 X B7 B6 G7 G6 R7 R6 X B7 B6
tCLK
DCLK 0.5 Vcc
tHP
Hsync t
WH
Data Enable
tVP
tWV
Vsync tVFP
tVBP tWVA
Data Enable
Black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Red 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0
Green 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0
Basic Blue 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1
Color Cyan 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1
Magenta 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1 1 1 1
Yellow 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0
White 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
RED (00) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
RED (01) 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0
RED … … … …
RED (62) 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0
RED (63) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0
GREEN (00) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
GREEN (01) 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0
GREEN ... … … …
GREEN (62) 0 0 0 0 0 0 1 1 1 1 1 0 0 0 0 0 0 0
GREEN (63) 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0
BLUE (00) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
BLUE (01) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1
BLUE … … … …
BLUE (62) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0
BLUE (63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1
T3 T7 T4
T1 T2 Valid Data
Interface Signal, Vi
LVDS
0V
T5 3.0V 3.0V T6
LED on/off control Signal
0V (Off)
LED_EN
T9 T10
90% 90%
LED input Voltage
VLED 0V 10% T12 T13 10%
Note)
1. Do not insert the mating cable when system turn on.
2. Valid Data have to meet “3-3. LVDS Signal Timing Specifications”
3. LVDS, LED_EN and PWM need to be on pull-down condition on invalid status.
4. LGD recommend the rising sequence of VLED after the Vcc and valid status of LVDS turn on.
4. Optical Specification
Optical characteristics are determined after the unit has been ‘ON’ and stable for approximately 20 minutes in
a dark environment at 25°C. The values specified are at an approximate distance 50cm from the LCD surface
at a viewing angle of Φ and Θ equal to 0°.
FIG. 1 presents additional information concerning the measurement equipment and method.
±50mm
500mm±
Note)
1. Contrast Ratio(CR) is defined mathematically as
2. Surface luminance is the average of 5 point across the LCD surface 50cm from the surface with
all pixels displaying white. For more information see FIG 1.
3. The variation in surface luminance , The panel total variation (δ WHITE) is determined by measuring LN
at each test position 1 through 13 and then defined as following numerical formula.
For more information see FIG 2.
4. Response time is the time required for the display to transition from white to black (rise time, TrR) and
from black to white(Decay Time, TrD). For additional information see FIG 3.
5. Viewing angle is the angle at which the contrast ratio is greater than 10. The angles are determined
for the horizontal or x axis and the vertical or y axis with respect to the z axis which is normal to the
LCD surface. For more information see FIG 4.
FIG. 2 Luminance
<Measuring point for Average Luminance & measuring point for Luminance variation>
H
10mm A
6 7 8 10mm
2 3
B H,V : ACTIVE AREA
V A : H/4 mm
9 1 10
B : V/4 mm
POINTS: 13 POINTS
4 5 13
11 12
Optical
Response
10
0 white white
black
φ = 180 ° ,
Left θ
φ = 0° ,
Right
φ = 270 ° ,
Down
5. Mechanical Characteristics
The contents provide general mechanical characteristics for the model LP140WH2. In addition the figures
in the next page are detailed mechanical drawing of the LCD.
Horizontal 309.40 mm
Active Display Area
Vertical 173.95 mm
6. Reliability
7. International Standards
7-1. Safety
a) UL 60950-1, Second Edition, Underwriters Laboratories Inc.
Information Technology Equipment - Safety - Part 1 : General Requirements.
b) CAN/CSA C22.2 No.60950-1-07, Second Edition, Canadian Standards Association.
Information Technology Equipment - Safety - Part 1 : General Requirements.
c) EN 60950-1:2006 + A11:2009, European Committee for Electrotechnical Standardization (CENELEC).
Information Technology Equipment - Safety - Part 1 : General Requirements.
d) IEC 60950-1:2005, Second Edition, The International Electrotechnical Commission (IEC).
Information Technology Equipment - Safety - Part 1 : General Requirements.
7-2. EMC
7-3. Environment
a) RoHS, Directive 2002/95/EC of the European Parliament and of the council of 27 January 2003
8. Packing
8-1. Designation of Lot Mark
a) Lot Mark
A B C D E F G H I J K L M
Note
1. YEAR
Year 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010
Mark 1 2 3 4 5 6 7 8 9 0
2. MONTH
Month Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Mark 1 2 3 4 5 6 7 8 9 A B C
9. PRECAUTIONS
Please pay attention to the followings when you use this TFT LCD module.
(2) Response time depends on the temperature.(In lower temperature, it becomes longer.)
(3) Brightness depends on the temperature. (In lower temperature, it becomes lower.)
And in lower temperature, response time(required time that brightness is stable after turned on) becomes
longer.
(4) Be careful for condensation at sudden temperature change. Condensation makes damage to polarizer or
electrical contacted parts. And after fading condensation, smear or spot will occur.
(5) When fixed patterns are displayed for a long time, remnant image is likely to occur.
(6) Module has high frequency circuits. Sufficient suppression to the electromagnetic interference shall be
done by system manufacturers. Grounding and shielding methods may be important to minimized the
interference.
9-5. STORAGE
When storing modules as spares for a long time, the following precautions are necessary.
(1) Store them in a dark place. Do not expose the module to sunlight or fluorescent light. Keep the
temperature between 5°C and 35°C at normal humidity.
(2) The polarizer surface should not come in contact with any other object.
It is recommended that they be stored in the container in which they were shipped.